Normal Values of Left Ventricular Longitudinal and Circumferential Layer-Specific Strain: A Meta-Analysis

Abstract

Background: Layer-specific strain is a relatively recent tool that is supposed to improve myocardial deformation assessment. Although it has been used to explore various cardiovascular diseases, there is no recommendation to use this tool in clinical practice. Moreover, there are few data concerning normal values of layer-specific strain in healthy individuals. Our aim was to perform a meta-analysis to determine normal ranges of longitudinal and circumferential layer-specific strain values and define factors that could influence layer-specific strain normal values. Methods: We searched Medline, Embase and Cochrane database using the following code: (((layer specific[Title/Abstract] OR multilayer[Title/Abstract])) AND (Strain[Title/Abstract] OR speckle tracking[Title/Abstract])) AND echocardiography[Title/Abstract], completing this search on May, 2019. All studies reporting left ventricular longitudinal or circumferential layer-specific strain (endocardial, mid-myocardial and epicardial) in healthy normal subjects were included. Results: 869 subjects from 18 studies were included. Normal values for longitudinal layer-specific strain at endocardial, mid-myocardial, and epicardial layer were respectively when considering EchoPAC software: −23.90 ± 0.62, −23.90 ± 0.62, −18.10 ± 1.54; Toshiba software: −15.73 ± 0.92, −15.73 ± 0.92, −12.06 ± 0.30 and VVI software: −19.10 ± 1.30, −19.09 ± 1.30, −10.80 ± 1.00. Circumferential endocardial, mid-myocardial and epicardial layer-specific strain normal values were for EchoPAC software: −31.74 ± 1.56, −22.84 ± 0.90, −17.15 ± 1.30. There was only one study for VVI and Toshiba software. There was a gradient between endocardial and epicardial strain with layer-specific strain decreasing from endocardial to epicardial layer. Main limit of reproducibility of this tool was intervendor variability. Conclusion: Normal ranges of layer-specific strain (longitudinal and circumferential) are provided in this meta-analysis according to 3 vendors: EchoPAC, Toshiba and VVI. Layer-specific strain decreases from the endocardial to the epicardial layer in both longitudinal and circumferential strain. Main cause of variability was the intervendor variability in monolayer strain. Effort for standardization between vendors should be required.

Share and Cite:

Barry, A. , Bourkhissi, I. and Bah, A. (2026) Normal Values of Left Ventricular Longitudinal and Circumferential Layer-Specific Strain: A Meta-Analysis. World Journal of Cardiovascular Diseases, 16, 853-864. doi: 10.4236/wjcd.2026.1611078.

1. Background

Assessment of left ventricle (LV) function using global longitudinal strain (GLS) is recommended in cancer patients receiving chemotherapy at risk of cardiotoxicity (anthracycline, trastuzumab). Normal value of LV GLS using speckle tracking tool is −20% [1]. However, it has been recognized that this tool could suffer from different factors of variability as: age, sex, and systolic arterial pressure [2] [3]. Effort to standardized method to define strain assessment has been performed with consensus between industrials and clinicians [4].

Layer-specific strain (LSS) is a relatively recent tool that is supposed to improve myocardial deformation assessment. It provides evaluation of myocardial deformation in three layers: endocardial, mid-myocardial and epicardial using speckle tracking. It has been tested in various conditions, such as myocardial ischemia [5]-[11], presence of cardiovascular risk factors [12]-[15], and cardio-oncology [16] [17]. Nevertheless, there is no recommendation to use LSS in clinical practice. There are few data concerning normal values of layer-specific strain in healthy individuals, which must be required before being able to preconize widespread of this technique. As found for monolayer strain, LSS may present various parameters that could influence the measurement of strain, including features specific to patients: age, sex, hemodynamic factors, and specific to the technology with an intervendor variability [18]. The routine application of LSS in clinical practice requires to define normal ranges and knowledge of main causes of variability.

The objective of this study was to perform a meta-analysis to determine normal ranges of longitudinal and circumferential LSS and define main factors of variability of these measurements.

2. Methods

We performed a wide research in Medline, Embase and Cochrane database using the following code: (((layer specific[Title/Abstract] OR multilayer[Title/Abstract])) AND (Strain[Title/Abstract] OR speckle tracking[Title/Abstract])) AND echocardiography[Title/Abstract] completing this search on May, 2019.

All articles were selected by two operators independently (YA, AM) and when they were discordant, they ended up at a consensus.

Studies were included if it provided LV LSS using two-dimensional speckle-tracking echocardiography in healthy normal subjects, either in the control group or as the main objective of the study.

Only human studies written in English were assessed for inclusion. Furthermore, the reference lists of these articles were scrutinized to further identify studies pertinent to the topic. All studies that reported LV longitudinal or circumferential layer-specific strain: endocardial (endo), mid-myocardial (mid) and epicardial (epi) in healthy normal subjects were included.

Studies that were excluded had the following criteria: use of 2-layer-specific strain (endocardial, epicardial) without assessment of mid-myocardial layer, no evaluation in human subjects, inclusion of children, assessment of right ventricular strain, case report or review, abstracts without full text, editorial comments, and letters to the editor.

Clinical, echocardiographic, and strain data were extracted from individual studies by one author (AM), verified by a second (YA) and entered into an electronic database. Mean and standard deviations for longitudinal and circumferential LSS were extracted from the text and tables.

Data recorded in a database were: author, years of publication, sex, age, heart rate, systolic arterial pressure, body mass index, and values of longitudinal and circumferential LSS of each layer from healthy control group.

The search strategy, study selection and analysis adhered to PRISMA Guidelines [19].

Statistical Analysis

The overall means and 95% CIs of longitudinal and circumferential LSS were computed using fixed-effects models with inverse variance weighting as pooling method. Between-study heterogeneity was assessed by measuring inconsistency (I2, the percentage of total variance across studies attributable to heterogeneity of results rather than chance). We performed a fixed-effects meta-regression for variables suspected to influence strain to assess their effect on normal LSS variation, such as the mean age of patients in studies and the software used. Statistical analysis was performed using standard and metafor packages in R software 4.0.3 with two-tailed tests and p-values < 0.05 considered as significant.

3. Results

3.1. Study Selection

A total of 95 titles were screened and 18 studies were included in this meta-analysis. Therefore, 869 patients were included in this analysis. Figure 1 presents the flow chart for the selection of studies and the reasons for exclusion of others. Table 1 presents main demographic and clinical characteristics of the population. 17 studies analyzed longitudinal LSS, and 10 circumferential LSS.

3.2. Normal Ranges

Longitudinal LSS

Normal values for longitudinal LSS are presented in Table 2. When considering EchoPAC software, longitudinal endocardial, mid-myocardial and epicardial LSS were respectively: −23.90 ± 0.62, −23.90 ± 0.62, −18.10 ± 1.54. When considering Toshiba software, longitudinal endocardial, mid-myocardial and epicardial LSS were respectively −15.73 ± 0.92, −15.73 ± 0.92, −12.06 ± 0.30. When considering VVI software, longitudinal endocardial, mid-myocardial and epicardial LSS were respectively −19.10 ± 1.30, −19.09 ± 1.30, −10.80 ± 1.00.

Circumferential LSS

When considering Circumferential LSS, only values obtained with EchoPAC software were summarized in Table 2 because there was only one study respectively for Toshiba and VVI software that analyzed the circumferential LSS.

When considering EchoPAC software, circumferential endocardial, mid-myocardial and epicardial LSS were respectively −31.74 ± 1.56, −22.84 ± 0.90, −17.15 ± 1.30. When considering Toshiba software, circumferential endocardial, mid-myocardial and epicardial LSS were respectively −24.3 ± 3.3, −13.3 ± −2.5, 8.6 ± 2.3 [20]. When considering VVI software, circumferential endocardial, mid-myocardial and epicardial LSS were respectively −18.8 ± 5.1, −13.1 ± 3.6, −8.8 ± 2.7 [21].

Strain values are higher in EchoPAC than in VVI and Toshiba regardless of the type of strain (endocardial, mid-myocardial, epicardial).

Figure 1. Study design. Flow chart presenting the selection process for published reports.

Table 1. Characteristics of the study population.

Author/Years

n

Sex Female n (%)

Age (Years)

BMI

PAS (mmHg)

HR

LVEF

Bogdanović et al., 2019 [28]

20

12 (60)

36.2 ± 2

23.8 ± 0.7

NA

NA

65.1 ± 0.4

Ozkaramanli Gur et al., 2018 [21]

30

13 (43.3)

38.5 ± 9.9

25.1 ± 3.9

118 ± 15.7

75.5

63.8 ± 4.2

Sun et al., 2019 [29]

80

17 (21.2)

50.8 ± 12.4

NA

121.8 ± 10.5

70 ± 10.7

65 ± 6.4

Xu et al., 2018 [14]

67

NA

NA

21.3 ± 2.3

NA

67 ± 11

65 ± 6

Kang et al., 2018 [17]

27

15 (55.6)

50.4 ± 13.4

NA

124.8 ± 12.6

78 ± 11.3

66.5 ± 5.6

Abou et al., 2017 [24]

94

40 (42.6)

54 ± 16

25 ± 3.4

NA

NA

62 ± 6.2

Cho et al., 2017 [30]

18

10 (55.6)

60.9 ± 7.19

NA

120 ± 15.8

74 ± 12

65.2 ± 5.5

Tadic et al., 2017 [12]

38

35 (92)

53 ± 8

25.1 ± 3.1

128 ± 8

73 ± 9

64 ± 3

Leng et al., 2017 [15]

32

15 (46.9)

35.6 ± 10.3

NA

118 ± 11.6

68.6 ± 6.6

66 ± 2.8

Tadic et al., 2018 [31]

44

22 (50)

52 ± 8

26.4 ± 2.2

127 ± 9

68 ± 6

65 ± 4

Cong et al., 2016 [32]

30

30 (100)

28.2 ± 6.6

NA

104.2 ± 10.7

81 ± 14

67.6 ± 5.1

Kim et al., 2016 [13]

31

12 (38.7)

62.5 ± 8.7

24.7 ± 3.2

126 ± 13

NA

63.5 ± 5.9

Wang et al., 2016 [33]

44

22 (50%)

55.5 ± 8.4

NA

126.8 ± 14.6

68.7 ± 7.5

64.5 ± 4.4

Shi et al., 2016 [25]

119

60 (50.4)

48 ± 9.3

23.5 ± 2.9

110.2 ± 12.9

66 ± 9.6

63.4 ± 2.9

Okada et al., 2015 [20]

27

12 (44.4)

53 ± 9.7

NA

119.4 ± 12.2

67 ± 11

65 ± 4.2

Cadeddu et al., 2014 [34]

18

18 (100)

52 ± 5.3

25.6 ± 3.2

128 ± 11

75 ± 13

67 ± 9.2

Bachner-Hinenzon et al., 2010 [35]

120

NA

NA

NA

NA

69 ± 1.1

61 ± 0.7

Adamu et al., 2009 [5]

30

10 (33.3)

60.5 ± 16.5

NA

NA

NA

59 ± 3.2

BMI: Body mass index; HR: Heart rate; LVEF: Left ventricle ejection fraction. NA means not available (non-disponible in French).

Table 2. Normal values of longitudinal and circumferential layer-specific strain according to vendor considering 3 layers.

Longitudinal LSS

Layer

Endo

I2

Mid

I2

Epi

I2

EchoPAC

23.90 ± 0.62

98.90

23.90 ± 0.62

98.90

18.10 ± 1.54

99.89

VVI

19.10 ± 1.30

94.86

19.09 ± 1.30

94.86

10.80 ± 1.00

93.77

Toshiba

15.73 ± 0.92

92.63

15.73 ± 0.92

92.63

12.06 ± 0.30

0.00

Circumferential LSS

Layer

Endo

I2

Mid

I2

Epi

I2

EchoPAC

31.74 ± 1.56

98.34

22.84 ± 0.90

96.61

17.15 ± 1.30

98.60

Endo: Endocardial; Mid: Mid-myocardial; Epi: Epicardial.

3.3. Factors Associated with Layer-Specific Strain Normal Values

A large part of the heterogeneity was thus explained by the vendor.

Due to the lack of data in various studies, the other potential variability factors of layer-specific strain were not studied. We limited ourselves to the study of correlations between LSS and different clinical and echocardiography characteristics.

Longitudinal layer-specific strain (Table 3):

Factors associated with longitudinal LSS for endocardial layer were: Body mass index (BMI), Body surface area (BSA), LVEF and vendors. Factors associated with longitudinal LSS for mid-myocardial layer were: BMI, BSA, LVEF and vendors. Factors associated with longitudinal LSS for epicardial layer were: BSA, LVEF and vendors.

Circumferential layer-specific strain (Table 4):

Factors associated with circumferential LSS for endocardial layer were: Female gender, BSA and vendors. Factors associated with circumferential LSS for mid-myocardial layer were: Age, heart rate and vendors. Factors associated with circumferential LSS for epicardial layer were: age, heart rate, systolic blood pressure and vendors.

Table 3. Factors associated with longitudinal layer-specific strain values considering all vendors (meta-regression).

Factors

Endocardial Layer

Mid-Myocardial Layer

Epicardial Layer

CC

p

CC

p

CC

p

Female gender

0.22 ± 2.02

0.91

−0.39 ± 1.54

0.80

−0.60 ± 1.34

0.66

Age

−0.06 ± 0.04

0.18

−0.03 ± 0.03

0.28

−0.03 ± 0.03

0.31

BMI

−0.71 ± 0.26

0.01

−0.49 ± 0.21

0.02

−0.34 ± 0.19

0.08

BSA

−7.69 ± 2.97

0.01

−5.91 ± 2.34

0.01

−4.52 ± 2.35

0.05

HR

0.05 ± 0.10

0.64

0.03 ± 0.11

0.77

0.05 ± 0.15

0.71

LVEF

0.59 ± 0.22

0.01

0.76 ± 0.21

0.00

1.04 ± 0.26

<0.001

SBP

−0.02 ± 0.06

0.73

−0.01 ± 0.05

0.76

−0.01 ± 0.04

0.74

DBP

0.05 ± 0.10

0.59

0.03 ± 0.08

0.64

0.05 ± 0.06

0.46

Toshiba software

−8.17 ± 1.36

<0.0001

−6.72 ± 1.35

<0.0001

−5.94 ± 1.73

0.0006

VVI software

−4.80 ± 1.37

0.0004

−6.08 ± 1.33

<0.0001

−7.29 ± 1.72

<0.0001

BMI: Body mass index; BSA: Body surface area; HR: Heart rate; LVEF: Left ventricle ejection fraction; SBP: Systolic blood pressure; DBP: Diastolic blood pressure.

Table 4. Factors associated with circumferential layer-specific strain values considering all vendors (meta-regression).

Factors

Endocardial Layer

Mid-Myocardial Layer

Epicardial Layer

CC

p

CC

p

CC

p

Female gender

−14.4 ± 6.12

0.02

−4.64 ± 5.00

0.35

0.13 ± 6.89

0.98

Age

0.17 ± 0.23

0.46

0.37 ± 0.11

0.0005

0.52 ± 0.12

<0.0001

BMI

−0.74 ± 0.76

0.33

0.26 ± 0.15

0.08

0.71 ± 0.65

0.28

BSA

−20.28 ± 9.47

0.03

−5.12 ± 5.23

0.33

−0.74 ± 9.23

0.94

HR

0.39 ± 0.35

0.27

0.50 ± 0.15

0.0013

0.65 ± 0.22

0.003

LVEF

−0.72 ± 0.68

0.29

−0.72 ± 0.47

0.12

−0.95 ± 0.57

0.10

SBP

−0.33 ± 0.23

0.15

0.20 ± 0.14

0.15

0.48 ± 0.13

0.0002

DBP

−0.29 ± 0.52

0.58

−0.15 ± 0.32

0.63

−0.12 ± 0.44

0.77

Toshiba software

−7.43 ± 4.39

0.09

−9.56 ± 2.87

0.0009

−8.54 ± 3.75

0.02

VVI software

−12.93 ± 4.44

0.0036

−9.76 ± 2.90

0.0008

−8.34 ± 3.75

0.03

BMI: Body mass index; BSA: Body surface area; HR: Heart rate; LVEF: Left ventricle ejection fraction; SBP: Systolic blood pressure; DBP: Diastolic blood pressure.

3.4. Gradient

There is a gradient between endocardial and epicardial strain. For both longitudinal and circumferential LSS, normal value decreases from the endocardial to epicardial layer.

4. Discussion

To our knowledge, this study is the first meta-analysis that aimed to define longitudinal and circumferential LSS. Main results were as follows: When considering EchoPAC software, normal values for longitudinal LSS were −23.90 ± 0.62 (endo), −23.90 ± 0.62 (mid), −18.10 ± 1.54 (epi). When considering Toshiba software, normal values for longitudinal LSS were −15.73 ± 0.92 (endo), −15.73 ± 0.92 (mid), −12.06 ± 0.30 (epi). When considering VVI software, normal values were −19.10 ± 1.30 (endo), −19.09 ± 1.30 (mid), −10.80 ± 1.00 (epi). Circumferential endocardial, mid-myocardial and epicardial layer-specific strain for EchoPAC software were respectively −31.74 ± 1.56, −22.84 ± 0.90, and −17.15 ± 1.30. There is a gradient between endocardial and epicardial strain. Longitudinal and circumferential LSS decrease from the endocardial to epicardial layer.

Layer-specific strain normal values:

Few studies have aimed to specifically define normal range of longitudinal and circumferential LSS in healthy individuals. Furthermore, for this work we only included studies which consider 3 layers (endo, mid, epi) and excluded those considering only two layers [22] [23].

Shi et al. performed a prospective observational study with aim to define reference value of both longitudinal and circumferential LSS and investigate the impact of age, gender, and other physiologic factors. Results revealed a gradient of strain with a value of LSS decreasing from endocardial to epicardial layer. Mean global longitudinal strain in the endocardial layer, in the mid-myocardial layer and in the epicardial layer were −24.3% ± 3.1%, −21.3% ± 2.9%, and −18.9% ± 2.8%, respectively. Mean global circumferential strain in the endocardial layer, in the mid-myocardial layer and in the epicardial layer were −34.3% ± 4.4%, −20.5% ± 3.0%, and −11.8% ± 2.7%, respectively. In an observational study, Abou et al. specify influence of increasing age on variation of longitudinal and circumferential LSS normal values. Their results demonstrated that with increasing age, the magnitude of LV longitudinal strain at the basal level declines while the apical LV longitudinal strain increases. Moreover, only presence of diabetes mellitus modulated the effect of age on the LV endocardial layer, and male gender was associated with more impaired longitudinal strain at the epicardial layer [24].

Factors of LSS variability:

Factors of variability described for monolayer strain are: age, sex, systolic arterial pressure and intervendor variability [2] [3]. Takigiku et al. [3] found that gender, body surface area and blood pressure were significantly correlated with global longitudinal strain. There was a difference between three vendors. It was advisable to follow-up patients with the same model of machine.

Our results revealed a positive correlation between longitudinal LSS and LVEF and negative correlation with BSA, BMI and vendors. Main cause of variability was intervendor variability.

Shi et al. demonstrated that factors which were correlated to longitudinal LSS were: Gender, Heart Rate, and Stroke Volume and Heart Rate was correlated to circumferential LSS [25].

Intervendor variability must be considered as a limit of LSS reproducibility. In a previous study [18], we assessed intervendor variability by comparing two vendors: Vivid E9TM (General Electric) and the ACUSON SC2000TM (Siemens). 80 patients receiving chemotherapy for cancer were including prospectively and echocardiography were realized by two operators with two types of machine. For a given vendor, strain values decreased from the endocardial layer to the epicardial layer, and strain values obtained with Acuson SC2000 platform were systematically lower than those obtained with Vivid E9 platform (p < 0.0001) [18]. In this study, subjects were followed for a cancer, whereas in our study, subjects were normal.

Manovel et al. [26] performed 2-D speckle tracking analyses on 28 healthy adult subjects using ultrasound systems and software from GE (General Electric/EchoPAC) and Toshiba. They found a good comparability for global longitudinal strain (between GE and Toshiba), but not for circumferential strain. To explain this difference, the considerable out-of-plane motion of acoustic markers in short-axis views could also represent a limitation for the consistency of findings when transmural and circumferential motion are analysed. In addition, the presence of a transmural deformation gradient and differently oriented myofibril layers within the left ventricular wall should be kept in mind, since the initial position from which myocardial acoustic markers start to be tracked might differ between software.

Takigiku et al. [3] highlighted that the contribution of image quality to tracking feasibility differs with vendors. The smallest difference between 3 vendors was noted in the Longitudinal global strain compared to radial and circumferential strain. In addition to the different tracking algorithms used, image quality, post-processing and interpolation techniques, and the computation of the strain, the method of averaging data from the adjacent region and the different weighted averaging computational methods in each of the regions of interest increase the inaccuracies. The different regions of interest between vendors explain partially the different values. The detailed algorithms speckle tracking used in the systems from individual vendors are proprietary and not visible for the user.

In addition, there are multiple definitions of LSS. There is layer-specific strain with 3 layers as in our studies, or 2 layers [22] [23] [27]. This difference in definition of LSS contributes in a certain way to the variability of the values. Normal values for 2-layer-specific strain proposed by Nagata et al. were: −23.1 ± 2.3 (endo) and −17.6 ± 1.9 (epi) with EchoPAC software [23]. Alcidi et al. found normal values: 25.4 ± 2.1 (endo) and 21.1 ± 1.8 (epi) [22].

Main limits of the study:

Firstly, meta-analysis has inherent limitations: the heterogeneity of the studies, for example, which was important in this study. Secondly, assessment of cause of variability in the measurement of the strain was incomplete because of lack of data. We just studied correlation between different factors, including layer-specific strain, age, BMI, BSA, HR, blood pressure, LVEF, and type of vendor’s model. However, we analyzed normal values per vendor to evaluate differences.

5. Conclusion

This study is the first meta-analysis that defines both longitudinal and circumferential LSS normal ranges considering 3 different vendors: EchoPAC, Toshiba and VVI Software. There is a gradient between endocardial and epicardial strain, in normal subjects, LSS decreases from the endocardial to the epicardial layer. There is an intervendor variability in monolayer strain. Effort for standardization between vendors should be required before recommending widespread use of this tool.

Abbreviations

LV

Left ventricle

LVEF

Left ventricle ejection fraction

GLS

Global longitudinal strain

GCS

Global circumferential strain

LSS

Layer-specific strain

Endo

Endocardial

Mid

Mid-myocardial

Epi

Epicardial

BMI

Body mass index

BSA

Body surface area

VVI

Velocity vector imaging

Conflicts of Interest

The authors declare no conflicts of interest regarding the publication of this paper.

References

[1] Lang, R.M., Badano, L.P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., et al. (2015) Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Journal of the American Society of Echocardiography, 28, 1-39.e14.[CrossRef] [PubMed]
[2] Yingchoncharoen, T., Agarwal, S., Popović, Z.B. and Marwick, T.H. (2013) Normal Ranges of Left Ventricular Strain: A Meta-Analysis. Journal of the American Society of Echocardiography, 26, 185-191.[CrossRef] [PubMed]
[3] Takigiku, K., Takeuchi, M., Izumi, C., Yuda, S., Sakata, K., Ohte, N., et al. (2012) Normal Range of Left Ventricular 2-Dimensional Strain: Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) Study. Circulation Journal, 76, 2623-2632.[CrossRef] [PubMed]
[4] Voigt, J., Pedrizzetti, G., Lysyansky, P., Marwick, T.H., Houle, H., Baumann, R., et al. (2015) Definitions for a Common Standard for 2D Speckle Tracking Echocardiography: Consensus Document of the EACVI/ASE/Industry Task Force to Standardize Deformation Imaging. European Heart Journal-Cardiovascular Imaging, 16, 1-11.[CrossRef] [PubMed]
[5] Adamu, U., Schmitz, F., Becker, M., Kelm, M. and Hoffmann, R. (2009) Advanced Speckle Tracking Echocardiography Allowing a Three-Myocardial Layer-Specific Analysis of Deformation Parameters. European Journal of Echocardiography, 10, 303-308.[CrossRef] [PubMed]
[6] Mandoli, G.E., Cameli, M., Minardi, S., Crudele, F., Lunghetti, S. and Mondillo, S. (2018) Layer-Specific Strain in Dipyridamole Stress Echo: A New Tool for the Diagnosis of Microvascular Angina. Echocardiography, 35, 2005-2013.[CrossRef] [PubMed]
[7] Sarvari, S.I., Haugaa, K.H., Zahid, W., Bendz, B., Aakhus, S., Aaberge, L., et al. (2013) Layer-Specific Quantification of Myocardial Deformation by Strain Echocardiography May Reveal Significant CAD in Patients with Non-ST-Segment Elevation Acute Coronary Syndrome. JACC: Cardiovascular Imaging, 6, 535-544.[CrossRef] [PubMed]
[8] Liu, C., Li, J., Ren, M., Wang, Z., Li, Z., Gao, F., et al. (2016) Multilayer Longitudinal Strain at Rest May Help to Predict Significant Stenosis of the Left Anterior Descending Coronary Artery in Patients with Suspected Non-ST-Elevation Acute Coronary Syndrome. The International Journal of Cardiovascular Imaging, 32, 1675-1685.[CrossRef] [PubMed]
[9] Liu, K., Wang, Y., Hao, Q., Li, G., Chen, P. and Li, D. (2019) Evaluation of Myocardial Viability in Patients with Acute Myocardial Infarction: Layer-Specific Analysis of 2-Dimensional Speckle Tracking Echocardiography. Medicine, 98, e13959.[CrossRef] [PubMed]
[10] Becker, M., Ocklenburg, C., Altiok, E., Futing, A., Balzer, J., Krombach, G., et al. (2009) Impact of Infarct Transmurality on Layer-Specific Impairment of Myocardial Function: A Myocardial Deformation Imaging Study. European Heart Journal, 30, 1467-1476.[CrossRef] [PubMed]
[11] Orloff, E., Fournier, P., Bouisset, F., Moine, T., Cournot, M., Elbaz, M., et al. (2018) Myocardial Multilayer Strain Does Not Provide Additional Value for Detection of Myocardial Viability Assessed by SPECT Imaging over and Beyond Standard Strain. Echocardiography, 35, 1300-1309.[CrossRef] [PubMed]
[12] Tadic, M., Zlatanovic, M., Cuspidi, C., Ivanovic, B., Stevanovic, A., Damjanov, N., et al. (2017) The Relationship between Left Ventricular Deformation and Heart Rate Variability in Patients with Systemic Sclerosis: Two-and Three-Dimensional Strain Analysis. International Journal of Cardiology, 236, 145-150.[CrossRef] [PubMed]
[13] Kim, S., Park, S., Kim, M. and Shim, W.J. (2016) Assessment of Left Ventricular Function by Layer-Specific Strain and Its Relationship to Structural Remodelling in Patients with Hypertension. Canadian Journal of Cardiology, 32, 211-216.[CrossRef] [PubMed]
[14] Xu, L., Wang, N., Chen, X., Liang, Y., Zhou, H. and Yan, J. (2018) Quantitative Evaluation of Myocardial Layer-Specific Strain Using Two-Dimensional Speckle Tracking Echocardiography among Young Adults with Essential Hypertension in China. Medicine, 97, e12448.[CrossRef] [PubMed]
[15] Leng, Z., Li, R., Li, Y., Wang, L., Wang, Y. and Yang, Y. (2017) Myocardial Layer-Specific Analysis in Patients with Heterozygous Familial Hypercholesterolemia Using Speckle Tracking Echocardiography. Echocardiography, 34, 390-396.[CrossRef] [PubMed]
[16] Yazaki, K., Takahashi, K., Shigemitsu, S., Yamada, M., Iso, T., Kobayashi, M., et al. (2018) In-Depth Insight into the Mechanisms of Cardiac Dysfunction in Patients with Childhood Cancer after Anthracycline Treatment Using Layer-Specific Strain Analysis. Circulation Journal, 82, 715-723.[CrossRef] [PubMed]
[17] Kang, Y., Xiao, F., Chen, H., Wang, W., Shen, L., Zhao, H., et al. (2018) Subclinical Anthracycline-Induced Cardiotoxicity in the Long-Term Follow-Up of Lymphoma Survivors: A Multi-Layer Speckle Tracking Analysis. Arquivos Brasileiros de Cardiologia, 110, 219-228.[CrossRef] [PubMed]
[18] Ancedy, Y., Ederhy, S., Lang, S., Hollebecque, A., Dufour, L.S., Adavane-Scheuble, S., et al. (2018) Multilayer Global Longitudinal Strain in Patients with Cancer: A Comparison of Two Vendors. Archives of Cardiovascular Diseases, 111, 285-296.[CrossRef] [PubMed]
[19] Moher, D., Liberati, A., Tetzlaff, J. and Altman, D.G. (2009) Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. PLOS Medicine, 6, e1000097.[CrossRef] [PubMed]
[20] Okada, K., Yamada, S., Iwano, H., Nishino, H., Nakabachi, M., Yokoyama, S., et al. (2015) Myocardial Shortening in 3 Orthogonal Directions and Its Transmural Variation in Patients with Nonobstructive Hypertrophic Cardiomyopathy. Circulation Journal, 79, 2471-2479.[CrossRef] [PubMed]
[21] Ozkaramanli Gur, D., Ozaltun, D.N., Guzel, S., Sarifakioglu, B., Akyuz, A., Alpsoy, S., et al. (2018) Novel Imaging Modalities in Detection of Cardiovascular Involvement in Ankylosing Spondylitis. Scandinavian Cardiovascular Journal, 52, 320-327.[CrossRef] [PubMed]
[22] Alcidi, G.M., Esposito, R., Evola, V., Santoro, C., Lembo, M., Sorrentino, R., et al. (2017) Normal Reference Values of Multilayer Longitudinal Strain According to Age Decades in a Healthy Population: A Single-Centre Experience. European Heart Journal-Cardiovascular Imaging, 19, 1390-1396.[CrossRef] [PubMed]
[23] Nagata, Y., Wu, V.C., Otsuji, Y. and Takeuchi, M. (2017) Normal Range of Myocardial Layer-Specific Strain Using Two-Dimensional Speckle Tracking Echocardiography. PLOS ONE, 12, e0180584.[CrossRef] [PubMed]
[24] Abou, R., Leung, M., Khidir, M.J.H., Wolterbeek, R., Schalij, M.J., Ajmone Marsan, N., et al. (2017) Influence of Aging on Level and Layer-Specific Left Ventricular Longitudinal Strain in Subjects without Structural Heart Disease. The American Journal of Cardiology, 120, 2065-2072.[CrossRef] [PubMed]
[25] Shi, J., Pan, C., Kong, D., Cheng, L. and Shu, X. (2016) Left Ventricular Longitudinal and Circumferential Layer-Specific Myocardial Strains and Their Determinants in Healthy Subjects. Echocardiography, 33, 510-518.[CrossRef] [PubMed]
[26] Manovel, A., Dawson, D., Smith, B. and Nihoyannopoulos, P. (2010) Assessment of Left Ventricular Function by Different Speckle-Tracking Software. European Journal of Echocardiography, 11, 417-421.[CrossRef] [PubMed]
[27] Coiro, S., Huttin, O., Bozec, E., Selton-Suty, C., Lamiral, Z., Carluccio, E., et al. (2017) Reproducibility of Echocardiographic Assessment of 2D-Derived Longitudinal Strain Parameters in a Population-Based Study (The STANISLAS Cohort Study). The International Journal of Cardiovascular Imaging, 33, 1361-1369. [Google Scholar] [CrossRef] [PubMed]
[28] Bogdanović, J., Ašanin, M., Krljanac, G., Lalić, N.M., Jotić, A., Stanković, S., et al. (2019) Impact of Acute Hyperglycemia on Layer-Specific Left Ventricular Strain in Asymptomatic Diabetic Patients: An Analysis Based on Two-Dimensional Speckle Tracking Echocardiography. Cardiovascular Diabetology, 18, Article No. 68.[CrossRef] [PubMed]
[29] Sun, J., Xu, T., Ni, X., Yang, X., Hu, J., Wang, S., et al. (2019) Echocardiographic Strain in Hypertrophic Cardiomyopathy and Hypertensive Left Ventricular Hypertrophy. Echocardiography, 36, 257-265.[CrossRef] [PubMed]
[30] Cho, E.J., Park, S., Kim, E.K., Lee, G.Y., Chang, S., Choi, J., et al. (2017) Effects of Increased Left Ventricular Wall Thickness on the Myocardium in Severe Aortic Stenosis with Normal Left Ventricular Ejection Fraction: Two-and Three-Dimensional Multilayer Speckle Tracking Echocardiography. Echocardiography, 34, 511-522.[CrossRef] [PubMed]
[31] Tadic, M., Cuspidi, C., Vukomanovic, V., Ilic, S., Obert, P., Kocijancic, V., et al. (2018) Layer-Specific Deformation of the Left Ventricle in Uncomplicated Patients with Type 2 Diabetes and Arterial Hypertension. Archives of Cardiovascular Diseases, 111, 17-24.[CrossRef] [PubMed]
[32] Cong, J., Wang, Z., Jin, H., Wang, W., Gong, K., Meng, Y., et al. (2016) Quantitative Evaluation of Longitudinal Strain in Layer-Specific Myocardium during Normal Pregnancy in China. Cardiovascular Ultrasound, 14, Article No. 45.[CrossRef] [PubMed]
[33] Wang, Y., Ma, C., Zhang, Y., Guan, Z., Liu, S., Li, Y., et al. (2016) Layer-Specific Analysis of Left Ventricular Myocardial Contractility in Patients with Coronary Slow-Flow Phenomenon. Journal of Clinical Ultrasound, 44, 429-436.[CrossRef] [PubMed]
[34] Cadeddu, C., Nocco, S., Deidda, M., Pau, F., Colonna, P. and Mercuro, G. (2014) Altered Transmural Contractility in Postmenopausal Women Affected by Cardiac Syndrome X. Journal of the American Society of Echocardiography, 27, 208-214.[CrossRef] [PubMed]
[35] Bachner-Hinenzon, N., Ertracht, O., Leitman, M., Vered, Z., Shimoni, S., Beeri, R., et al. (2010) Layer-Specific Strain Analysis by Speckle Tracking Echocardiography Reveals Differences in Left Ventricular Function between Rats and Humans. American Journal of Physiology-Heart and Circulatory Physiology, 299, H664-H672.[CrossRef] [PubMed]

Copyright © 2026 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.