Radiative Stopping Power Calculations of Electrons over the 1 keV-1 GeV Energy Range in Some Biological Materials ()
1. Introduction
As a charged particle moves through a material, it interacts primarily through Coulomb forces with the negatively charged electrons and positively charged nuclei that constitute the atoms of that material. As a result of these interactions, the charged particle continuously loses energy and eventually stops after traversing a finite distance. The average energy loss of charged particles along their tracks is expressed as the stopping power. The total stopping power of electrons is generally divided into two components: the collision stopping power and the radiative stopping power.
Collision stopping power expresses the average energy loss per unit path length due to inelastic Coulomb collisions with bound atomic electrons of the medium, causing ionization and excitation. Radiative stopping power expresses the average energy loss per unit path length due to bremsstrahlung emission arising from interactions with the electric fields of atomic nuclei and atomic electrons. The collision stopping power of light charged particles was first calculated by Bohr using classical arguments. Subsequently, several theories of collision stopping power were developed, some based on quantum mechanics, as formulated by Bethe and Bloch, and others based on dielectric response theory, as developed by Lindhard (1954) and Ritchie (1959) [1].
Over the years, numerous researchers have conducted both empirical and theoretical studies on the calculation of stopping power for electrons and positrons. Based on Bethe’s theory (1930), the range and stopping power of electrons over the 1 keV-1000 MeV energy range have been calculated for various materials [2]. Electronic stopping power of electrons of 5 eV - 10 MeV energy range in some materials taking into account the concept of effective charge developed by Sugiyama (1985) and Rohrlich and Carlson (1954) has been calculated [3]. Stopping power and CSDA range of electrons and positrons of 100 eV - 1GeV energy range in some biological compounds have been calculated [4]. Stopping power and mean free path (MFP) of electrons of 20 eV - 10 keV energy range in some organic compounds have been calculated [5]. Stopping power of positrons of 50 eV - 10 MeV energy range in some organic compounds has been calculated [6]. A new formula for stopping power of electrons of 200 eV - 30 keV energy range for 37 solids has been developed [7]. Stopping power of electrons of low and medium energy range in some biological compounds has been calculated [8]. By using modified Bethe-Bloch stopping power formula and taking into account the effective charge concept, the stopping power and range of electrons of 5 eV - 10 MeV energy range in some human body tissues have been calculated [9]. By using the Bethe-Bloch stopping power formula, the stopping power and range of electrons of 0.01 MeV - 1000 MeV energy range in some target materials have been calculated [10]. Density effect correction of charged particles for various substances has been calculated and tabulated [11]. The primary objective of this work is to calculate the mass radiative stopping power of electrons over the energy range of 1 keV to 1 GeV in biological materials, including elemental carbon and oxygen, as well as compound tissues such as testicular and prostate tissue, using analytical formulas derived from various theoretical models. The calculated results are subsequently compared with available reference data to assess their accuracy and validity.
2. Materials and Methods
2.1. Mass Collision Stopping Power
The collision stopping power is due to the energy transfer from the incident particle to the bound atomic electrons of the medium. The mass collision stopping power of incident electrons at medium and high energies has been expressed as in Eq.1 [12]-[14].
(1)
Where,
MeV·cm2·mol−1, β is the ratio of the velocity (v) of the incident particle to the speed of light (β = v/c). τ is the kinetic energy of the incident electron or positron in units of rest mass, E is the kinetic energy of the incident particle, A is the mass number of the target material, Z is the atomic number of the target material, I is the mean excitation energy of the target material, z is the charge of the incident particle, mc2 is the electron rest mass energy (mc2 = 0.511MeV). F(τ) is an energy dependent function and is expressed in Eq.2.
(2)
2.2. Density Effect Correction
Density effect correction (δ), is a second correction term applied to the Bethe collision stopping power equation to account for the polarization or density effect in condensed media. The asymptotic formula of density effect correction at high energies was introduced by Fano as in Eq.3 [15] [16].
(3)
Where,
is plazma energy (eV), γ is Lorentz factor and ρ is the density of target material in unit of (g/cm3).
2.3. Determination of Z, A and I of the Compounds
The mass collision stopping power and mass radiative stopping power calculations of the compounds were performed by considering its elemental compositions. The atomic number and mass number of each compound were determinated using additive rules given by Eqs. 4 and 5. Whereas, mean excitation energy of each compound were determinated using bragg-kleeman additive rule given by Eq. 6 [11] [16].
(4)
(5)
(6)
Where,
,
,
and
are respectively weight fraction, atomic number, mass number and mean excitation energy of i element in the compound target.
2.4. Mass Radiative Stopping Power
When an electron is deflected by scattering from a nucleus or from an atomic electron, it is briefly accelerated and can emit radiation. Its accompanying energy loss is the radiative stopping power of the target material, and is known as Bremsstrahlung. There are many analytical expressions used for radiative stopping power calculations.
For high energy (E >> m0c2) the ratio of radiative stopping power to collision stopping power of electrons introduced by Bhabha in 1938 is given in Eq.7 [17] [18].
(7)
Where, Z is atomic number of the target material, E is kinetic energy of incident electron in MeV and n is a constatnt variously taken to be 700 or 800 MeV.
Another general formula of the mass radiative stopping power for high energies (complete screening, τ ≫ 1/αz1/3) based on quantum-mechanical theories was introduced by Bethe and Heitler in 1934 is given in Eq. 8 [18] [19].
(8)
Where, Z is atomic number of target material, α is fine structure constant, re is classical radius of electron, NA is avogadro number, τ is the kinetic energy of the incident electron in units of rest mass, m0c2 is the electron rest mass energy (0.511 MeV).
Considering the Bremsstrahlung and radiation length X0 (Z), one of the expressions used for mass radiative stopping power calculations was first introduced by Bethe and Heitler (1934) and modified by Wheeler and Lamb in 1939 is given in Eq.9 [20] [21].
(9)
(10)
Where, Z, α, re and NA were defined before as in Eq.8.
Considering the Bremsstrahlung and radiation length X0 (Z), another expression used for mass radiative stopping power calculations introduced by Tsai in 1974 is given in Eq.11 [4] [22] [23].
(11)
Where, E is the kinetic energy of the incident particle (electron) in MeV, X0 (Z) is called the radiation length and is given in Eq. 12.
(12)
Where, Z is atomic number of target material, f(z) is an atomic number dependent function and is expressed in Eq. 13. The
and
values are given in Table 1.
Table 1.
and
values related to values of Z.
Element |
Z |
|
|
H |
1 |
5.31 |
6.144 |
He |
2 |
4.79 |
5.621 |
Li |
3 |
4.74 |
5.805 |
Be |
4 |
4.71 |
5.924 |
Others |
>4 |
|
|
(13)
Table 2. Material composition of testicular and prostate tissues (ICRU, 1992).
Weight Fractions |
Element |
Testes |
Prostate |
H |
0.106 |
0.105 |
C |
0.099 |
0.256 |
O |
0.020 |
0.027 |
N |
0.766 |
0.602 |
Na |
0.002 |
0.001 |
P |
0.001 |
0.002 |
S |
0.002 |
0.003 |
Cl |
0.002 |
0.002 |
K |
0.002 |
0.002 |
Density (g/cm3) |
1.040 |
1.045 |
3. Results and Discussion
The mass radiative stopping power of electrons over the 1 keV m- 1 GeV energy range in amorphous carbon, oxygen, testicular tissue, and prostate tissue was calculated and tabulated (Tables 3-6) using analytical equations from different models.
Figure 1. Mass radiative stopping power in amorphous carbon as a function of incident electron energy.
The obtained results were plotted (Figures 1-4) and compared with one another, as well as with results from the ESTAR program and the PENELOPE Monte Carlo code [24]-[26]. The material composition and density of testicular and prostate tissues used as target materials were obtained from ICRU (1992) (Table 2).
Figure 2. Mass radiative stopping power in oxygen as a function of incident electron energy.
Figure 3. Mass radiative stopping power in testicular tissue as a function of incident electron energy.
For each target material and over the respective energy range, Eq. (7) was evaluated for different values of n, and the best-fitting values that yielded results closest to the reference data was were found to be 575, 800, 625, and 615 for amorphous carbon, oxygen, testicular tissue, and prostate tissue, respectively.
Figure 4. Mass radiative stopping power in prostate tissue as a function of incident electron energy.
The obtained values of n were employed in the mass radiative stopping power calculations for the corresponding target materials. As shown in Figures 1-4, a clear discrepancy between the reference and calculated data was observed for energies below 0.5 MeV, with this difference becoming more pronounced at lower energies. Furthermore, as the energy increases, the difference between the calculated and reference data decreases. The results obtained using the formula introduced by Bhabha were found to be closest to the reference data, and the corresponding curves exhibited similar behavior (Figures 1-4). In addition, the radiative stopping power formulas introduced by Bethe and Heitler, Wheeler and Lamb, and Tsai were based on a linear fit, with the results from the latter two (Wheeler and Lamb, and Tsai) found to be very close to each other.
Table 3. Mass radiative stopping power results of electrons in amorphous carbon.
Energy (MeV) |
STP_rad (MeV.cm2/g) |
Bhabha, 1938 |
Bethe and Heitler, 1934 |
Wheeler and Lamb, 1939 |
Tsai, 1974 |
Penelope 2014 |
ESTAR |
0.001 |
0.00109 |
0.00004 |
0.00002 |
0.00002 |
0.00251 |
- |
0.002 |
0.00138 |
0.00009 |
0.00004 |
0.00004 |
0.00284 |
- |
0.004 |
0.00167 |
0.00017 |
0.00009 |
0.00009 |
0.00304 |
- |
0.006 |
0.00185 |
0.00026 |
0.00013 |
0.00013 |
0.00310 |
- |
0.008 |
0.00198 |
0.00035 |
0.00017 |
0.00017 |
0.00313 |
- |
0.01 |
0.00208 |
0.00043 |
0.00022 |
0.00022 |
0.00314 |
0.00315 |
0.02 |
0.00244 |
0.00086 |
0.00044 |
0.00044 |
0.00316 |
0.00318 |
0.04 |
0.00288 |
0.00170 |
0.00088 |
0.00088 |
0.00320 |
0.00322 |
0.06 |
0.00322 |
0.00251 |
0.00132 |
0.00133 |
0.00326 |
0.00327 |
0.08 |
0.00353 |
0.00329 |
0.00176 |
0.00177 |
0.00333 |
0.00334 |
0.1 |
0.00382 |
0.00405 |
0.00220 |
0.00221 |
0.00340 |
0.00341 |
0.2 |
0.00519 |
0.00758 |
0.00441 |
0.00442 |
0.00387 |
0.00390 |
0.4 |
0.00798 |
0.01377 |
0.00882 |
0.00885 |
0.00516 |
0.00517 |
0.6 |
0.01097 |
0.01931 |
0.01323 |
0.01327 |
0.00675 |
0.00676 |
0.8 |
0.01412 |
0.02451 |
0.01764 |
0.01770 |
0.00855 |
0.00856 |
1 |
0.01741 |
0.02951 |
0.02204 |
0.02212 |
0.01052 |
0.01053 |
2 |
0.03518 |
0.05307 |
0.04409 |
0.04424 |
0.02209 |
0.02213 |
4 |
0.07088 |
0.09818 |
0.08818 |
0.08848 |
0.05030 |
0.05026 |
6 |
0.10777 |
0.14267 |
0.13227 |
0.13272 |
0.08213 |
0.08193 |
8 |
0.14534 |
0.18698 |
0.17636 |
0.17696 |
0.11608 |
0.11580 |
10 |
0.18337 |
0.23120 |
0.22045 |
0.22119 |
0.15149 |
0.15130 |
20 |
0.37774 |
0.45195 |
0.44090 |
0.44239 |
0.34130 |
0.34170 |
40 |
0.77791 |
0.89305 |
0.88181 |
0.88478 |
0.74912 |
0.75080 |
60 |
1.18650 |
1.33410 |
1.32270 |
1.32720 |
1.17402 |
1.17500 |
80 |
1.60060 |
1.77510 |
1.76360 |
1.76960 |
1.60837 |
1.60800 |
100 |
2.01870 |
2.21600 |
2.20450 |
2.21190 |
2.04888 |
2.04600 |
200 |
4.14870 |
4.42090 |
4.40900 |
4.42390 |
4.29506 |
4.27600 |
400 |
8.51950 |
8.83050 |
8.81810 |
8.84780 |
8.85980 |
8.82000 |
600 |
12.97400 |
13.24000 |
13.22700 |
13.27200 |
13.46000 |
13.40000 |
800 |
17.48300 |
17.65000 |
17.63600 |
17.69600 |
18.07680 |
18.01000 |
1000 |
22.03200 |
22.05900 |
22.04500 |
22.11900 |
22.70830 |
22.62000 |
Table 4. Mass radiative stopping power results of electrons in oxygen.
Energy (MeV) |
STP_rad (MeV.cm2/g) |
Bhabha, 1938 |
Bethe and Heitler, 1934 |
Wheeler and Lamb, 1939 |
Tsai, 1974 |
Penelope 2014 |
ESTAR |
0.001 |
0.00098 |
0.00005 |
0.00002 |
0.00002 |
0.00307 |
- |
0.002 |
0.00126 |
0.00010 |
0.00005 |
0.00005 |
0.00361 |
- |
0.004 |
0.00154 |
0.00021 |
0.00010 |
0.00010 |
0.00400 |
- |
0.006 |
0.00171 |
0.00031 |
0.00016 |
0.00016 |
0.00415 |
- |
0.008 |
0.00183 |
0.00042 |
0.00021 |
0.00021 |
0.00422 |
- |
0.01 |
0.00193 |
0.00052 |
0.00026 |
0.00026 |
0.00426 |
0.00427 |
0.02 |
0.00227 |
0.00104 |
0.00053 |
0.00052 |
0.00431 |
0.00434 |
0.04 |
0.00269 |
0.00205 |
0.00106 |
0.00106 |
0.00436 |
0.00438 |
0.06 |
0.00302 |
0.00302 |
0.00159 |
0.00159 |
0.00442 |
0.00443 |
0.08 |
0.00331 |
0.00396 |
0.00213 |
0.00211 |
0.00450 |
0.00451 |
0.1 |
0.00358 |
0.00488 |
0.00266 |
0.00264 |
0.00459 |
0.00461 |
0.2 |
0.00487 |
0.00913 |
0.00531 |
0.00529 |
0.00519 |
0.00522 |
0.4 |
0.00751 |
0.01659 |
0.01063 |
0.01057 |
0.00684 |
0.00686 |
0.6 |
0.01033 |
0.02327 |
0.01594 |
0.01586 |
0.00888 |
0.00890 |
0.8 |
0.01332 |
0.02954 |
0.02125 |
0.02115 |
0.01121 |
0.01122 |
1 |
0.01643 |
0.03555 |
0.02656 |
0.02643 |
0.01374 |
0.01376 |
2 |
0.03336 |
0.06395 |
0.05313 |
0.05287 |
0.02861 |
0.02869 |
4 |
0.07096 |
0.11831 |
0.10626 |
0.10573 |
0.06473 |
0.06471 |
6 |
0.11123 |
0.17192 |
0.15938 |
0.15860 |
0.10525 |
0.10510 |
8 |
0.15317 |
0.22531 |
0.21251 |
0.21146 |
0.14839 |
0.14820 |
10 |
0.19631 |
0.27861 |
0.26564 |
0.26433 |
0.19338 |
0.19320 |
20 |
0.42365 |
0.54462 |
0.53128 |
0.52865 |
0.43319 |
0.43430 |
40 |
0.91050 |
1.07620 |
1.06260 |
1.05730 |
0.94666 |
0.95020 |
60 |
1.42150 |
1.60760 |
1.59380 |
1.58600 |
1.47989 |
1.48400 |
80 |
1.94810 |
2.13900 |
2.12510 |
2.11460 |
2.02409 |
2.02800 |
100 |
2.48640 |
2.67040 |
2.65640 |
2.64330 |
2.57597 |
2.57700 |
200 |
5.10050 |
5.32730 |
5.31280 |
5.28650 |
5.38527 |
5.37100 |
400 |
10.41400 |
10.64100 |
10.62600 |
10.57300 |
11.08670 |
11.05000 |
600 |
15.80800 |
15.95500 |
15.93800 |
15.86000 |
16.82420 |
16.78000 |
800 |
21.25400 |
21.26900 |
21.25100 |
21.14600 |
22.58370 |
22.52000 |
1000 |
26.73800 |
26.58200 |
26.56400 |
26.43300 |
28.35210 |
28.27000 |
Table 5. Mass radiative stopping power results of electrons in testes tissue.
Energy (MeV) |
STP_rad (MeV.cm2/g) |
Bhabha, 1938 |
Bethe and Heitler, 1934 |
Wheeler and Lamb, 1939 |
Tsai, 1974 |
Penelope 2014 |
ESTAR |
0.001 |
0.00127 |
0.00005 |
0.00002 |
0.00002 |
0.00279 |
- |
0.002 |
0.00159 |
0.00010 |
0.00005 |
0.00005 |
0.00325 |
- |
0.004 |
0.00191 |
0.00020 |
0.00010 |
0.00010 |
0.00359 |
- |
0.006 |
0.00210 |
0.00030 |
0.00014 |
0.00014 |
0.00372 |
- |
0.008 |
0.00225 |
0.00040 |
0.00019 |
0.00019 |
0.00378 |
- |
0.01 |
0.00236 |
0.00049 |
0.00024 |
0.00025 |
0.00382 |
0.00383 |
0.02 |
0.00275 |
0.00097 |
0.00049 |
0.00049 |
0.00387 |
0.00389 |
0.04 |
0.00324 |
0.00191 |
0.00099 |
0.00098 |
0.00392 |
0.00394 |
0.06 |
0.00363 |
0.00282 |
0.00149 |
0.00148 |
0.00398 |
0.00400 |
0.08 |
0.00397 |
0.00370 |
0.00198 |
0.00198 |
0.00405 |
0.00407 |
0.1 |
0.00429 |
0.00455 |
0.00248 |
0.00247 |
0.00414 |
0.00416 |
0.2 |
0.00581 |
0.00852 |
0.00496 |
0.00495 |
0.00470 |
0.00473 |
0.4 |
0.00893 |
0.01547 |
0.00991 |
0.00989 |
0.00622 |
0.00624 |
0.6 |
0.01226 |
0.02171 |
0.01487 |
0.01484 |
0.00811 |
0.00813 |
0.8 |
0.01578 |
0.02755 |
0.01982 |
0.01979 |
0.01025 |
0.01027 |
1 |
0.01945 |
0.03316 |
0.02478 |
0.02473 |
0.01259 |
0.01260 |
2 |
0.03937 |
0.05965 |
0.04955 |
0.04946 |
0.02632 |
0.02638 |
4 |
0.08019 |
0.11035 |
0.09911 |
0.09892 |
0.05976 |
0.05969 |
6 |
0.12186 |
0.16036 |
0.14866 |
0.14838 |
0.09733 |
0.09710 |
8 |
0.16427 |
0.21015 |
0.19822 |
0.19785 |
0.13739 |
0.13710 |
10 |
0.20719 |
0.25986 |
0.24777 |
0.24731 |
0.17918 |
0.17880 |
20 |
0.42647 |
0.50797 |
0.49554 |
0.49461 |
0.40243 |
0.40280 |
40 |
0.87757 |
1.00370 |
0.99108 |
0.98923 |
0.88149 |
0.88290 |
60 |
1.33790 |
1.49940 |
1.48660 |
1.48380 |
1.37967 |
1.38100 |
80 |
1.80430 |
1.99510 |
1.98220 |
1.97850 |
1.88843 |
1.88700 |
100 |
2.27510 |
2.49070 |
2.47770 |
2.47310 |
2.40450 |
2.40000 |
200 |
4.67260 |
4.96890 |
4.95540 |
4.94610 |
5.03335 |
5.00800 |
400 |
9.58930 |
9.92510 |
9.91080 |
9.89230 |
10.37130 |
10.32000 |
600 |
14.59800 |
14.88100 |
14.86600 |
14.83800 |
15.74540 |
15.67000 |
800 |
19.66600 |
19.83800 |
19.82200 |
19.78500 |
21.14060 |
21.04000 |
1000 |
24.77900 |
24.79400 |
24.77700 |
24.73100 |
26.54610 |
26.43000 |
Table 6. Mass radiative stopping power results of electrons in prostate tissue.
Energy (MeV) |
STP_rad (MeV.cm2/g) |
Bhabha, 1938 |
Bethe and Heitler, 1934 |
Wheeler and Lamb, 1939 |
Tsai, 1974 |
Penelope 2014 |
ESTAR |
0.001 |
0.00125 |
0.00005 |
0.00002 |
0.00002 |
0.00270 |
- |
0.002 |
0.00155 |
0.00009 |
0.00005 |
0.00004 |
0.00313 |
- |
0.004 |
0.00187 |
0.00019 |
0.00009 |
0.00009 |
0.00344 |
- |
0.006 |
0.00206 |
0.00028 |
0.00014 |
0.00014 |
0.00356 |
- |
0.008 |
0.00220 |
0.00038 |
0.00019 |
0.00019 |
0.00362 |
- |
0.01 |
0.00231 |
0.00047 |
0.00024 |
0.00024 |
0.00365 |
0.00366 |
0.02 |
0.00269 |
0.00094 |
0.00048 |
0.00048 |
0.00369 |
0.00372 |
0.04 |
0.00317 |
0.00186 |
0.00096 |
0.00096 |
0.00374 |
0.00376 |
0.06 |
0.00354 |
0.00274 |
0.00145 |
0.00144 |
0.00380 |
0.00382 |
0.08 |
0.00387 |
0.00359 |
0.00193 |
0.00193 |
0.00388 |
0.00389 |
0.1 |
0.00418 |
0.00443 |
0.00241 |
0.00241 |
0.00396 |
0.00398 |
0.2 |
0.00567 |
0.00828 |
0.00482 |
0.00482 |
0.00450 |
0.00453 |
0.4 |
0.00871 |
0.01505 |
0.00964 |
0.00963 |
0.00597 |
0.00599 |
0.6 |
0.01196 |
0.02111 |
0.01446 |
0.01445 |
0.00778 |
0.00780 |
0.8 |
0.01539 |
0.02679 |
0.01928 |
0.01926 |
0.00985 |
0.00986 |
1 |
0.01897 |
0.03225 |
0.02409 |
0.02408 |
0.01210 |
0.01211 |
2 |
0.03839 |
0.05801 |
0.04819 |
0.04816 |
0.02533 |
0.02539 |
4 |
0.07802 |
0.10731 |
0.09638 |
0.09632 |
0.05756 |
0.05750 |
6 |
0.11857 |
0.15594 |
0.14457 |
0.14448 |
0.09381 |
0.09358 |
8 |
0.15984 |
0.20436 |
0.19276 |
0.19264 |
0.13247 |
0.13210 |
10 |
0.20160 |
0.25270 |
0.24095 |
0.24080 |
0.17280 |
0.17240 |
20 |
0.41495 |
0.49398 |
0.48190 |
0.48160 |
0.38844 |
0.38870 |
40 |
0.85388 |
0.97611 |
0.96380 |
0.96319 |
0.85140 |
0.85250 |
60 |
1.30180 |
1.45810 |
1.44570 |
1.44480 |
1.33308 |
1.33400 |
80 |
1.75560 |
1.94010 |
1.92760 |
1.92640 |
1.82512 |
1.82300 |
100 |
2.21370 |
2.42210 |
2.40950 |
2.40800 |
2.32421 |
2.31900 |
200 |
4.54650 |
4.83200 |
4.81900 |
4.81600 |
4.86730 |
4.84200 |
400 |
9.33060 |
9.65180 |
9.63800 |
9.63190 |
10.03210 |
9.97700 |
600 |
14.20400 |
14.47200 |
14.45700 |
14.44800 |
15.23300 |
15.16000 |
800 |
19.13600 |
19.29100 |
19.27600 |
19.26400 |
20.45430 |
20.36000 |
1000 |
24.11000 |
24.11100 |
24.09500 |
24.08000 |
25.68660 |
25.57000 |
4. Conclusions
In this work, mass radiative stopping power calculations for incident electrons were performed over the 1 keV - 1 GeV energy range in selected elements and compounds using analytical equations derived from several theoretical models. Amorphous carbon and oxygen were selected as representative simple materials, while testicular and prostate tissues were selected as compound materials of direct biological and clinical relevance. All governing equations were implemented in a custom-developed computational code, and the resulting values were systematically compared with one another, as well as with reference data from the ESTAR program and PENELOPE Monte Carlo simulations, in order to assess the accuracy and reliability of each analytical model.
Taking into account the variation of the parameter n with target material, the radiative stopping power values obtained using the formula introduced by Bhabha showed the closest agreement with the reference data (PENELOPE and ESTAR) in the high-energy range. This is expected, as most of these models were proposed and validated for the high-energy range above 0.5 MeV. The Bhabha formula also consistently yielded the closest agreement with the reference data across all four investigated materials. It can therefore be recommended as a reliable and computationally efficient alternative to more resource-intensive Monte Carlo simulations for calculating the radiative stopping power of electrons in a wide range of target materials. Given that testicular and prostate tissues are biological (human) tissues of direct relevance to radiation dosimetry and radiotherapy, the evaluated stopping power data extend beyond simple elemental benchmarks and carry practical significance for medical physics applications. Accordingly, the dataset generated in this study can serve as a valuable input resource for dose calculations involving light-charged particles (electrons) in human tissue, with potential applications in treatment planning, radiation protection, and microdosimetry studies. Future work may extend this approach to a broader range of biological tissues and materials, as well as to other light-charged particles such as positrons, in order to further validate the generality of the Bhabha formula and support its integration into clinical dosimetry software.