<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SS</journal-id><journal-title-group><journal-title>Surgical Science</journal-title></journal-title-group><issn pub-type="epub">2157-9407</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ss.2014.510068</article-id><article-id pub-id-type="publisher-id">SS-50720</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Computer Science Tools for Manual Editing of Computed Tomographic Images: Impact on the Quality of 3D Printed Models
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ean</surname><given-names>H. D. Fasel</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jörg</surname><given-names>Beinemann</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Karl</surname><given-names>Schaller</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Heinz-Otto</surname><given-names>Peitgen</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff3"><addr-line>Department of Neurosurgery, University Hospitals, Geneva, Switzerland</addr-line></aff><aff id="aff4"><addr-line>Department of Mathematical Sciences, Florida Atlantic University, Boca Raton, USA</addr-line></aff><aff id="aff2"><addr-line>Hightech Research Center of Cranio-Maxillofacial Surgery, University of Basel, Basel, Switzerland</addr-line></aff><aff id="aff1"><addr-line>Clinical Anatomy Research Group, Department of Cellular Physiology and Metabolism, University Medical Center, Geneva, Switzerland</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>jean.fasel@unige.ch(EHDF)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>10</day><month>10</month><year>2014</year></pub-date><volume>05</volume><issue>10</issue><fpage>439</fpage><lpage>443</lpage><history><date date-type="received"><day>16</day>	<month>August</month>	<year>2014</year></date><date date-type="rev-recd"><day>15</day>	<month>September</month>	<year>2014</year>	</date><date date-type="accepted"><day>10</day>	<month>October</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Background: Three-dimensional printing (3DP) technologies are a trendsetting topic, also in the field of surgery. Preoperative planning for maxillofacial and neurological surgery, for instance, increasingly involves skull models obtained by 3DP. However, the cranial replicas currently used in this context have been shown to not reproduce the exact anatomy of the individual patient undergoing surgery. Objective: The present study aimed at investigating the extent to which manual editing, using current computer software tools, can improve skull models derived from medical images. Methods: Skull computed tomography (CT) was obtained on three cadavers and
   
  sent to three institutions that provide preoperative 3DP services. Each institute independently
   
  performed 3D reconstructions, including routine manual editing, and subsequently produced the replicas. The models were then qualitatively compared with the respective original skull. For
   
  quantitative comparison surface scans of particular regions of interest were made and the deviations assessed using 3-matic software (Materialise, Leuven, Belgium). Results: Routine manual editing of CT images resulted in replicas that were clear improvements over automatically generated reconstructions. This was particularly the case for teeth artefacts and thin-walled entities (e.g. paranasal sinuses). Conversely, however, many anatomical structures remained incorrectly rendered (e.g. orbitae, pterygoid processes, and sella turcica). Extraosseous calcifications had regularly not been removed. After extensive manual editing, however, replicas were able to provide largely submillimeter accuracy (mean deviation 0.2496 mm; standard deviation &#177;0.2276 mm). Conclusions: This study confirms that manual editing with current computer science tools does improve the quality of CT-based 3D printed skull models. But, it also demonstrates that a number of structures remain largely incorrectly rendered when edited in the presently used surgical framework. Conversely, it shows that highly accurate replicas are feasible, provided that extensive manual editing is performed.
 
</p></abstract><kwd-group><kwd>Preoperative Replicas</kwd><kwd> 3D Printing</kwd><kwd> Skull</kwd><kwd> Models</kwd><kwd> Accuracy</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Additive manufacturing technologies (such as stereolithography and selective laser sintering) refer to processes in which virtual mathematical 3D models are used to build up real physical objects through joining materials layer by layer. They can be thought of as the opposite of subtractive methods (such as drilling and milling) and are generally considered to hold huge potential for innovations, including medical applications [<xref ref-type="bibr" rid="scirp.50720-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.50720-ref2">2</xref>] . For surgery, for instance, models of human organs obtained by using three-dimensional printing (3DP) are being increasingly used for preoperative planning [<xref ref-type="bibr" rid="scirp.50720-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.50720-ref4">4</xref>] and postgraduate education [<xref ref-type="bibr" rid="scirp.50720-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.50720-ref6">6</xref>] .</p><p>As far as maxillofacial and neurological surgeries are concerned, the quality of the skull replicas currently obtained is generally accepted by surgeons, even though recent investigations have shown that these models do not reliably render the detailed anatomy of the individual patient [<xref ref-type="bibr" rid="scirp.50720-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.50720-ref8">8</xref>] , confirming reports from the 1990s [<xref ref-type="bibr" rid="scirp.50720-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.50720-ref10">10</xref>] .</p><p>In contrast to the said conventional opinion amongst clinicians, this paper presumes that, because of the strong trend towards minimally invasive and personalized surgery, it seems likely that more accurate skull models than those currently used will be needed. That is why the present study aimed to investigate the extent to which manual editing—using current computer software tools—can improve skull models derived from medical imaging, and thus integrate patient-specific data for procedural planning and educational purposes in surgery.</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>In accordance with the Swiss legislation that allows research on donated bodies, the craniofacial bony complexes of three cadavers donated to the Geneva anatomy department were acquired with computed tomography (CT) using routine clinical parameters (Somatom Sensation 64, Siemens, Erlangen, Germany), The DICOM data were then sent to three independent institutes with 3DP facilities. Each institute was asked to perform routine 3D reconstructions, including manual editing, and to produce a physical model of each skull for preoperative planning purposes. Detailed visual comparisons of the replicas were then carried out against the original skulls—region by region, structure by structure—according to the current international anatomical list [<xref ref-type="bibr" rid="scirp.50720-ref11">11</xref>] . For a quantitative analysis the surfaces of a replica and the respective original skull were scanned using an ATOS triple scan (GOM GmbH, Braunschweig, Germany). Deviations between the real and the manufactured skull were assessed using the Mimics Innovation Suite Research 3-matic software (Version 9.0; Materialise, Leuven, Belgium).</p></sec><sec id="s3"><title>3. Results</title><p>The topographic and systematic comparison of the replicas against their respective original skulls confirmed that routine manual editing of the CT images, using the above algorithms, yields unambiguous improvements in the models compared to reconstructions generated purely automatically. The most striking example concerned teeth artefacts (<xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>).</p><p>However, even after manual editing had been performed under a routine surgical context (such as preoperative planning purposes), many flaws in the replica remained unchanged. Extraosseous calcifications had frequently not been removed. For example, <xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>(A) and <xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>(B) show the region of a sella turcica in the case of advanced internal carotid artery atheromatosis, obstructing the view of the parasellar area in the replica. In <xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>(D) the model shows artefactual defects in the base of the medial plate of the pterygoid process.</p></sec><sec id="s4"><title>4. Discussion</title><p>This study’s results confirm that routine manual editing of computed tomographic skull images, using currently</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref></label><caption><title> Examples of 3D printed models of a mandible compared to the original specimen. (A) The original mandible. (B) The replica obtained via automatic segmentation of the CT images displays typical radiate teeth artefacts (indicated by asterisks:<sup>*</sup>). (C) A marked reduction of these artefacts after routine manual editing. The <xref ref-type="fig" rid="fig">Figure </xref>documents that 3D printed models can be improved by manual editing of the CT images</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-2300795x6.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref></label><caption><title> Examples of skull regions that are consistently incorrectly replicated despite routine manual editing. (A) and (C) show the regions in the original skulls. (B) and (D) are the corresponding areas in the 3D printed replicas.(A) and (B) show the sella turcica. Note the calcified internal carotid arteries (arrows) in the replica falsely mimicking a non-existent caroticoclinoid ring and hiding the middle clinoid processes. Further, note the artefactual foramen (arrowhead) in the bottom of the sella, which may suggest the presence of a craniopharyngeal canal. (C) and (D) show the base of the right medial pterygoid lamina. Note the presence of artefactual foramina (arrow) in the replica-not to be mistaken for accessory openings around the pterygoid (vidian) canal. The <xref ref-type="fig" rid="fig">Figure </xref>illustrates that routine manual editing can fail to yield 3D printed models that reliably reflect the detailed osseous anatomy of the individual patient’s skull</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-2300795x7.png"/></fig><p>available computer software tools, helps to improve the quality of 3D printed models as compared to those obtained using automated procedures (<xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>). However, the investigation also shows that manual editing—as is routinely performed in a clinical context (particularly for preoperative planning purposes)—is far from guaranteeing a true reproduction of the specific skull anatomy of the patient.</p><p>This finding is of immediate clinical relevance: A wrongly mimicked caroticoclinoid foramen (<xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>(B)) could have an impact on directing transsphenoidal endoscopic approaches, for example [<xref ref-type="bibr" rid="scirp.50720-ref12">12</xref>] . Artefactual foramina could be mistaken either for normal variants or for pathological conditions such as a craniopharyngeal canal [<xref ref-type="bibr" rid="scirp.50720-ref13">13</xref>] or accessory bony openings for neurovascular bundles around the pterygoid (vidian) canal (<xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>(D))—this canal being a useful landmark for a skull base neurosurgeon [<xref ref-type="bibr" rid="scirp.50720-ref14">14</xref>] carrying out a vidian neurectomy, for instance [<xref ref-type="bibr" rid="scirp.50720-ref15">15</xref>] .</p><p>In order to clarify whether, or to what extent, a much more detailed manual editing than is routinely done in a surgical context could reduce flaws, certain skull regions particularly prone to errors were further edited on one of the skulls. <xref ref-type="fig" rid="fig">Figure </xref>3 illustrates the results for the sella turcica. A further marked qualitative improvement was</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>3</label><caption><title> The impact of extensive manual editing of CT images on the quality of replicas. (A) The sella in the original skull. (B) The replica following extensive manual editing. (C) The quantitative comparison of both. Note the excellent qualitative and quantitative match between the 3D printed model and the original</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-2300795x8.png"/></fig><p>obtained. The errors observed after routine manual editing (<xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>(B)) were fully eliminated, the middle clinoid processes and their asymmetry became clearly visible, and the caroticoclinoid foramen was gone. The pseudo-craniopharyngeal canal also disappeared (<xref ref-type="fig" rid="fig">Figure </xref>3(B)).</p><p>Quantitatively, the conformity of the model was also excellent. <xref ref-type="fig" rid="fig">Figure </xref>3(C) shows the corresponding color-coded deviation graph. The median deviation was 0.1836 mm (range 0.0000 mm to 1.4368 mm); the mean deviation amounted to 0.2496 mm (standard deviation &#177;0.2276 mm). However, it has to be noted that the extensive manual editing necessary for the only small region of interest illustrated in <xref ref-type="fig" rid="fig">Figure </xref>3 took ten hours to carry out. This is obviously beyond the scope of any standard clinical context.</p><p>Highly accurate replicas (with largely submillimeter accuracy) are, therefore, obtainable using current computer software tools for manual editing. However, providing anatomical models of such quality is only possible with great expenditure of time and money and with provision of high professional anatomical standards.</p></sec><sec id="s5"><title>5. Conclusion</title><p>This investigation confirms that manual editing using current computer software tools can improve the quality of 3D printed physical replicas based on CT images. However, it also demonstrates that a number of structures are still largely incorrectly rendered when edited following routine surgical frameworks. In view of the increasing demand for minimally invasive and personalized surgical procedures, it seems likely that surgeons will need more accurate skull models than those currently used. This study shows that highly accurate reproductions, both qualitatively and quantitatively, are indeed feasible if extensive manual editing is performed.</p></sec><sec id="s6"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.50720-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Esses, S.J., Berman, P., Bloom, A.I., et al. (2011) Clinical Applications of Physical 3D Models Derived from MDCT Data and Created by Rapid Prototyping. American Journal of Roentgenology, 196, W683-W688.  
http://dx.doi.org/10.2214/AJR.10.5681</mixed-citation></ref><ref id="scirp.50720-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Rengier, F., Mehndiratta, A., von Tengg-Kobligk, H., et al. (2010) 3D Printing Based on Imaging Data: Review of Medical Applications. International Journal of Computer Assisted Radiology and Surgery, 5, 335-341.  
http://dx.doi.org/10.1007/s11548-010-0476-x</mixed-citation></ref><ref id="scirp.50720-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Spottiswoode, B.S., van den Heever, D.J., Chang, Y., et al. (2013) Preoperative Three-Dimensional Model Creation of Magnetic Resonance Brain Images as a Tool to Assist Neurosurgical Planning. Stereotactic and Functional Neurosurgery, 91, 162-169. http://dx.doi.org/10.1159/000345264</mixed-citation></ref><ref id="scirp.50720-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Zein, N.N., Hanouneh, I.A., Bishop, P.D., et al. (2013) Three-Dimensional Print of a Liver for Preoperative Planning in Living Donor Liver Transplantation. Liver Transplantation, 19, 1304-1310. http://dx.doi.org/10.1002/lt.23729</mixed-citation></ref><ref id="scirp.50720-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Waran, V., Narayanan, V., Karuppiah, R., et al. (2014) Injecting Realism in Surgical Training—Initial Simulation Experience with Custom 3D Models. Journal of Surgical Education, 71, 193-197.  
http://dx.doi.org/10.1016/j.jsurg.2013.08.010</mixed-citation></ref><ref id="scirp.50720-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Watson, R.A. (2014) A Low-Cost Surgical Application of Additive Fabrication. Journal of Surgical Education, 71, 14- 17. http://dx.doi.org/10.1016/j.jsurg.2013.10.012</mixed-citation></ref><ref id="scirp.50720-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Fasel, J.H.D., Beinemann, J., Schaller, K., et al. (2013) A Critical Inventory of Preoperative Skull Replicas. Annals of The Royal College of Surgeons of England, 95, 401-404. http://dx.doi.org/10.1308/003588413X13629960046994</mixed-citation></ref><ref id="scirp.50720-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Huotilainen, E., Jaanimets, R., Valásek, J., et al. (2014) Inaccuracies in Additive Manufactured Medical Skull Models Caused by the DICOM to STL Conversion Process. Journal of Craniomaxillofacial Surgery, 42, e259-e265.  
http://dx.doi.org/10.1016/j.jcms.2013.10.001</mixed-citation></ref><ref id="scirp.50720-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Sader, R., Zeilhofer, H.F., Kliegis, U., et al. (1997) Precision of 3D-Assisted Surgical Planning with Rapid Prototype Techniques. Mund-, Kieferund Gesichtschirurgie, 1, S61-S64.</mixed-citation></ref><ref id="scirp.50720-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Lill, W., Solar, P., Ulm, C., et al. (1992) Reproducibility of Three-Dimensional CT-Assisted Model Production in the Maxillofacial Area. British Journal of Oral and Maxillofacial Surgery, 30, 233-236.  
http://dx.doi.org/10.1016/0266-4356(92)90265-K</mixed-citation></ref><ref id="scirp.50720-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Federative Committee on Anatomical Terminology (FCAT) (1998) Terminologia Anatomica. Thieme, Stuttgart.</mixed-citation></ref><ref id="scirp.50720-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Peris-Celda, M., Kucukyuruk, B., Monroy-Sosa, A., et al. (2013) The Recesses for the Sellar Wall of the Sphenoid Sinus and Their Intracranial Relationships. Neurosurgery, 73, ons117-ons131.  
http://dx.doi.org/10.1227/NEU.0000000000000184</mixed-citation></ref><ref id="scirp.50720-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Abele, T.A., Salzman, K.L., Harnsberger, H.R., et al. (2014) Craniopharyngeal Canal and Its Spectrum of Pathology. American Journal of Neuroradiology (AJNR), 35, 772-777. http://dx.doi.org/10.3174/ajnr.A3745</mixed-citation></ref><ref id="scirp.50720-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Kassam, A.B., Vescan, A.D., Carrau, R.L., et al. (2008) Expanded Endonasal Approach: Vidian Canal as a Landmark to the Petrous Internal Carotid Artery. Journal of Neurosurgery, 108, 177-183.  
http://dx.doi.org/10.3171/JNS/2008/108/01/0177</mixed-citation></ref><ref id="scirp.50720-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Liu, S.C., Wang, H.W., Kao, H.L., et al. (2013) Three-Dimensional Bone CT Reconstruction Anatomy of the Vidian Canal. Rhinology, 51, 306-314.</mixed-citation></ref></ref-list></back></article>