<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJMN</journal-id><journal-title-group><journal-title>Open Journal of Modern Neurosurgery</journal-title></journal-title-group><issn pub-type="epub">2163-0569</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojmn.2014.44034</article-id><article-id pub-id-type="publisher-id">OJMN-50845</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Twiddler’s Syndrome in a Patient with Dystonic Tremor Treated with DBS
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ennifer</surname><given-names>Samuelsson</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Patric</surname><given-names>Blomstedt</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Department of Neurosurgery, Umea University, Umea, Sweden</addr-line></aff><aff id="aff1"><addr-line>Department of Neurosurgery, Umea University Hospital, Umea, Sweden</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>Jennifer.samuelsson@neuro.umu.se(ES)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>17</day><month>09</month><year>2014</year></pub-date><volume>04</volume><issue>04</issue><fpage>193</fpage><lpage>195</lpage><history><date date-type="received"><day>5</day>	<month>August</month>	<year>2014</year></date><date date-type="rev-recd"><day>5</day>	<month>September</month>	<year>2014</year>	</date><date date-type="accepted"><day>5</day>	<month>October</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Background and Importance: Twiddler’s syndrome is a rare complication of DBS. This condition occurs when the IPG is consciously or inadvertently rotated in its pocket, resulting in torsion and possible dislodgement of implanted electrodes, with subsequent loss of function. Methods: Here we present a patient diagnosed with Twiddler’s syndrome. The patient presented with straining cables at the neck five months after bilateral Gpi DBS and an x-ray demonstrated Twiddler’s syndrome. Initial revision with preventive measures proved futile. After some time the condition recurred, now with dislocation of one of the intracerebral electrodes. In a second revision the IPG was placed under the pectoralis muscle, which has so far prevented further rotation. Results and Conclusion: While Twiddler’s syndrome is fairly uncommon, it remains to be a risk associated with DBS, recognizing the potential risks and signs might allow for preventive measures avoiding dislocation of the intracerebral electrodes. 
 
</p></abstract><kwd-group><kwd>Twiddler’s Syndrome</kwd><kwd> IPG</kwd><kwd> DBS</kwd><kwd> Complications</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Twiddler’s syndrome, first time described in 1968 [<xref ref-type="bibr" rid="scirp.50845-ref1">1</xref>] , is a rare complication of DBS. This condition occurs when the IPG is consciously or inadvertently rotated in its pocket, resulting in torsion and possible dislodgement of implanted electrodes, with subsequent loss of function.</p><p>In this case report we present a patient diagnosed with Twiddler’s syndrome five months after the implantation and where the initial revision proved futile, leading to eventual dislocation of the intracerebral electrode.</p></sec><sec id="s2"><title>2. Case Report</title><p>A patient with dystonic tremor mainly in the head and upper extremities was implanted with bilateral electrodes (model 3389, Medtronic). An intra-operative CT fused with the pre-operative MR demonstrated the electrodes to be located in the intended target.</p><p>The electrodes were connected with two elastic extension cables (Model 37086, Medtronic) to a PC IPG (Medtronic). The IPG was placed in a subcutaneous pocket below the left clavicle on the fascia of the pectoralis muscle. The patient had a rather thick layer of subcutaneous fat and the area was very mobile, due to a large bosom.</p><p>Approximately 5 months after the procedure the patient experienced rotation of the pacemaker, sometimes necessitating manual correction on the patients behalf in order to get it back into the proper position. The patient did further experience tenderness behind the left ear above the connection between the extension cables and electrodes. An x-ray demonstrated rotation of the IPG with multiple twisting of the extension cables, however without affection of the intracerebral electrodes.</p><p>During the revision, the left extension cable was replaced and the IPG was put further down behind the breast, attached with two non-absorbable sutures and the IPG pocket was tightened.</p><p>Approximately seven months later the patient once again suffered the same symptoms. Imaging revealed an even more pronounced twisting of the extension cables and IPG (<xref ref-type="fig" rid="fig1">Figure 1</xref>(C)).The right intracerebral electrode was no longer in its original place, but had been pulled out 3 - 4 centimetres (<xref ref-type="fig" rid="fig1">Figure 1</xref>(A)). No apparent change was seen regarding the effect of DBS. The head tremor was still abolished, and no clear effect had ever been seen regarding the minor tremor in the right upper extremity.</p><p>During the second revision, the IPG was found rotated with the non-absorbable sutures ruptured (<xref ref-type="fig" rid="fig1">Figure 1</xref>(B)). The cable was re-winded and the IPG was this time implanted beneath the pectoralis muscle, fixated with non-absorbable sutures. An X-ray performed after three months demonstrated no signs of rotation of the IPG in its current position and no further clinical symptoms have emerged during the follow-up of 6 months.</p></sec><sec id="s3"><title>3. Discussion</title><p>Twiddler’s syndrome is a rare complication in DBS. It is caused by the rotation (intentionally or unintentionally) of the IPG around its long axis, sometimes causing dislocation of the electrodes.</p><p>However, this complication is well-known regarding cardiac pacemakers, where it is reported to occur in 0.7% - 7% of the patients.</p><p>Most patients are diagnosed within the first year and are more likely to develop in women who tend to have loose subcutaneous tissue [<xref ref-type="bibr" rid="scirp.50845-ref2">2</xref>] . Other risk factors facilitating rotation of the IPG include obesity, excessive movements of the upper limbs, increasing age, large size pockets and mentally unstable patients actively manipulating the IPG [<xref ref-type="bibr" rid="scirp.50845-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.50845-ref4">4</xref>] . Most of these risk factors cannot be avoided and in high-risk patients preventive measures might be considered, such as minimizing the IPG-pocket, attaching the IPG to the fascia or placing it sub-pectorally [<xref ref-type="bibr" rid="scirp.50845-ref3">3</xref>] . However, not even a placement below the muscle has proven to be a guarantee in the experience of cardiac pacemakers [<xref ref-type="bibr" rid="scirp.50845-ref3">3</xref>] .</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Demonstrating the dislocation of the left DBS-electrode (A), and the rotation of the extension cables on a plain X-ray (B) and during surgery (C)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/7-2080110x6.png"/></fig><p>This condition can easily be diagnosed radio-graphically and will often present itself clinically in a most distinct manner, with straining cables in the neck and a palpable coil of cables at the IPG. It should also be considered as a possibility in cases of sudden deterioration of the effect of DBS, or new stimulation induced side effects.</p></sec><sec id="s4"><title>4. Conclusion</title><p>While Twiddler’s syndrome is fairly uncommon, it remains to be a risk associated with DBS. Recognizing the potential risks and signs might allow for preventive measures avoiding dislocation of the intracerebral electrodes.</p></sec><sec id="s5"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.50845-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Fahraeus, T. and Hijer, C.J. (2003) Early Pacemaker Twiddler Syndrome. Europace, 5, 279-281. http://dx.doi.org/10.1016/S1099-5129(03)00032-1</mixed-citation></ref><ref id="scirp.50845-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Astradsson, A., Schweder, P.M., Joint, C., et al. (2011) Twiddler’s Syndrome in a Patient with a Deep Brain Stimulation Device for Generalized Dystonia. Journal of Clinical Neuroscience, 18, 970-972. http://dx.doi.org/10.1016/j.jocn.2010.11.012</mixed-citation></ref><ref id="scirp.50845-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Geissinger, G. and Neal, J.H. (2007) Spontaneous Twiddler’s Syndrome in a Patient with a Deep Brain Stimulator. Surgical Neurology, 68, 454-456. http://dx.doi.org/10.1016/j.surneu.2006.10.062</mixed-citation></ref><ref id="scirp.50845-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Gelabert-Gonzalez, M., Relova-Quinteiro, J.L. and Castro-Garcia, A. (2010) “Twiddler’s Syndrome” in Two Patients with Deep Brain Stimulation. Acta Neurochirurgica (Wien), 152, 489-491. http://dx.doi.org/10.1007/s00701-009-0366-6</mixed-citation></ref></ref-list></back></article>