<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">EPE</journal-id><journal-title-group><journal-title>Energy and Power Engineering</journal-title></journal-title-group><issn pub-type="epub">1949-243X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/epe.2020.123008</article-id><article-id pub-id-type="publisher-id">EPE-99172</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Numerical Study on NOx Emissions of Methane Re-Combustion in a 600 MWe Coal-Fired Boiler
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xiaotao</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hussain</surname><given-names>Ahmad Madni Gondal</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Foyuan</surname><given-names>Duan</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Weidong</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Haoliang</surname><given-names>Mu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Chengyu</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Aijun</surname><given-names>Wang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Departments of Electric Power, North China University of Water Resources and Electric Power, Zhengzhou, China</addr-line></aff><pub-date pub-type="epub"><day>26</day><month>03</month><year>2020</year></pub-date><volume>12</volume><issue>03</issue><fpage>101</fpage><lpage>107</lpage><history><date date-type="received"><day>29,</day>	<month>February</month>	<year>2020</year></date><date date-type="rev-recd"><day>24,</day>	<month>March</month>	<year>2020</year>	</date><date date-type="accepted"><day>27,</day>	<month>March</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The fuel staging combustion technology is a promising low NOx combustion technology for coal-fired boiler. In order to reduce NOx emissions, the burners of a 600
   
  MWe coal-fired boiler are retrofitted in which methane gas is selected as a secondary fuel for re-combustion. The CFD models of combustion process are built to investigate
   
  effects of the methane gasratio on combustion process and NOx emissions. A total of 4 cases are numerically studied, including the pure coal combustion case, the coal combustion with 7.5%, 10%, 12.5% of methane gas re-combustion cases respectively. The results show that the re-combustion of methane can reduce the temperature at primary combustion zone, but increase the temperatures at the re-combustion area and the furnace outlet. The NOx concentration at the furnace outlet reduces with the increasing methane gas ratio.
   
  Methane re-combustion can greatly benefit to the NOx emissions reduction.
 
</p></abstract><kwd-group><kwd>Numerical Simulation</kwd><kwd> Re-Combustion</kwd><kwd> NOx Emission Reduction</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The past many years have seen the emergence of a growing desire worldwide to take actions to protect the environment from the degrading effects of all forms of pollution. The gaseous pollutant NOx is a primary air pollution composition from the combustion of coal for power generation. A broad range of NOx control technologies have been employed [<xref ref-type="bibr" rid="scirp.99172-ref1">1</xref>]. The low NOx combustion and the flue gas de-nitrification technologies are the main methods to reduce nitrogen oxide emissions from coal-fired boilers. The fuel staging combustion technology is a promising technology at present [<xref ref-type="bibr" rid="scirp.99172-ref2">2</xref>]. The fuel staging combustion, also known as re-combustion, has been widely concerned by scholars. This technology reduces NOx emissions by setting up a less oxygen-burning section in furnace to restore a part of NOx to N<sub>2</sub> [<xref ref-type="bibr" rid="scirp.99172-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.99172-ref4">4</xref>]. There are several kinds of material that can be used as re-combustion fuel, such as ultra-fined coal, biomass raw materials and some combustible gases [<xref ref-type="bibr" rid="scirp.99172-ref5">5</xref>]. Gaseous fuels are the first choice for re-combustion because they are easier to be fully mixed and burnt out [<xref ref-type="bibr" rid="scirp.99172-ref6">6</xref>]. Zhang and others carried out the research of a biomass gasification gasifier coupled to a 330 MW coal-fired boiler, it was found that biomass gas has little impact on the normal boiler operation and can effectively reduce the emissions of NOx, SO<sub>2</sub> and other pollutants [<xref ref-type="bibr" rid="scirp.99172-ref7">7</xref>]. Glarborg et al. also carried out a study on the re-combustion characteristics of biomass gas, the results showed that, a higher methane concentration can lead to the greater NOx reduction rate at the excess air coefficient of 0.9 in re-combustion zone [<xref ref-type="bibr" rid="scirp.99172-ref8">8</xref>]. Shi et al. studied the effect of methane on the mixing characteristics of gas re-combustion in a coal-fired boiler [<xref ref-type="bibr" rid="scirp.99172-ref9">9</xref>]. Wu et al. studied the effect of biomass volatiles (CH<sub>4</sub>, CO, H<sub>2</sub> and CO<sub>2</sub>) on NO reduction of re-combustion de-nitrification technology. The results showed that the main positive factors of NO reduction are CH<sub>4</sub> and H<sub>2</sub> [<xref ref-type="bibr" rid="scirp.99172-ref10">10</xref>]. Su et al. performed the methane re-combustion de-nitrification test at four different levels of metamorphic coal species, the results showed that methane’s stay time in re-combustion area is at 0.7 - 0.9 s range, and the re-combustion de-nitrification efficiency is more than 50% [<xref ref-type="bibr" rid="scirp.99172-ref11">11</xref>]. Lu et al. indicated that the excessive air coefficient, the ammonia nitrogen ratio and other parameters at the re-combustion area have a great impact on de-nitrification efficiency [<xref ref-type="bibr" rid="scirp.99172-ref12">12</xref>]. Many early boilers had no re-combustion zone, causing high NOx emission. In this work, the re-combustion nozzles are added in the burner system to retrofit a 600 MW coal-fired boiler and methane is selected as the secondary fuel. The main objective is to investigate the influences of the methane co-firing ratio on boiler combustion characteristics and NOx emission. The results can provide a theoretical basis for retrofitting old units in service aiming NOx emission reduction.</p></sec><sec id="s2"><title>2. Boiler Characteristics</title><sec id="s2_1"><title>2.1. Research Objects and Burner Renovation Program</title><p>A 600 MWe super-supercritical boiler is taken as the research object. This is a single furnace tangential firing boiler with a body of 63.55 m high, 18.816 m wide and 17.696 m deep.</p><p>As shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>, the burner system before transformation is equipped with a total of 15-layer nozzles from bottom to top, including 6 layers of primary air nozzles (i.e., A, B, C, D, E and F), 7 layers of secondary air nozzles (i.e., AA, AB, BC, CD, DE, EF and FG), and 2 layers of separated over fire air nozzles (i.e., SOFA1 and SOFA2). The burner system is retrofitted by adding a layer of methane gas nozzles (i.e. G) and a layer of re-combustion air nozzles (i.e. GH). The combustion area of the furnace is divided into the primary combustion zone, the re-combustion zone and the burn-out zone after retrofit of burner system.</p></sec><sec id="s2_2"><title>2.2. NOx Emissions Reduction Mechanism</title><p>NOx generated in the furnace is divided into thermal type, fuel type and fast type. Its concentration is related to fuel characteristics and combustion conditions. NOx generated from coal combustion is due to high temperature at the primary combustion zone. As the re-combustion fuel is injected into furnace, a fuel-rich reductive atmosphere is formed. A part of NOx generated at the main combustion zone produces a reduction reaction in this area, being transformed to N<sub>2</sub>, hence the NOx emission is reduced.</p><p>The Methane as re-combustion fuel is broken down and produces a large amount of hydrocarbon root CHi to enhance the ability of reducing NOx. Therefore, it is considered one of most ideal re-combustion fuels.</p></sec><sec id="s2_3"><title>2.3. Input Parameters</title><p>In order to study the effect of methane re-combustion ratio on combustion process and NOx emissions in furnace, four cases are considered. The total heat input to the boiler is constant. The basic case is coal combustion without re-combustion; the other three cases are the coal combustion with 7.5%, 10% and 12.5% methane re-combustion ratio (according to heat input) respectively. The input parameters at 4 cases are shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p></sec></sec><sec id="s3"><title>3. Results and Discussions</title><sec id="s3_1"><title>3.1. The Temperature Distribution</title><p>The mean temperature distributions at horizontal cross-section in the furnace under different operating conditions are shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The mean temperature gradually increases with furnace height and reaches its peak at the height of 24 m, and then it gradually decreases. With the increase of re-combustion ratio, the temperature at main combustion zone decreases, but increases at re-combustion zone. The peak temperature at case 1 is around 1900 K, 51 - 72 K higher than that of case 2 - 4. Temperature at the furnace outlet of case 1 is about 1300 K, 10 - 36 K less than that of case 2 - 4. This actually revealed the combustion condition and was related to flue gas concentration.</p></sec><sec id="s3_2"><title>3.2. The Flue Gas Component Field Distribution</title><p>In this study, the main components in the flue gas are O<sub>2</sub>, CO, CO<sub>2</sub> and NO. The volume fractions of O<sub>2</sub>, CO, CO<sub>2</sub> and NOx mass concentration at each furnace horizontal cross-section under different operating conditions are shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><p>As seen from <xref ref-type="fig" rid="fig3">Figure 3</xref>, the changing trend of O<sub>2</sub> volume fraction is similar at different cases. The O<sub>2</sub> volume fraction of case1 at the primary combustion zone</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Input parameters under different operating conditions</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >case</th><th align="center" valign="middle" >1</th><th align="center" valign="middle" >2</th><th align="center" valign="middle" >3</th><th align="center" valign="middle" >4</th></tr></thead><tr><td align="center" valign="middle" >CH<sub>4</sub> Re-combustion ratio (γ/%)</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >7.5</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >12.5</td></tr><tr><td align="center" valign="middle" >Coal mass flow (B<sub>0</sub>/kg&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >3.09</td><td align="center" valign="middle" >2.86</td><td align="center" valign="middle" >2.78</td><td align="center" valign="middle" >2.70</td></tr><tr><td align="center" valign="middle" >Primary air speed (v<sub>1</sub>/m&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >25.45</td><td align="center" valign="middle" >25.13</td><td align="center" valign="middle" >25.04</td><td align="center" valign="middle" >24.94</td></tr><tr><td align="center" valign="middle" >Secondary air speed (v<sub>2</sub>/m&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >57.67</td><td align="center" valign="middle" >48.67</td><td align="center" valign="middle" >47.09</td><td align="center" valign="middle" >45.50</td></tr><tr><td align="center" valign="middle" >Separated over fire air speed (v<sub>SOFA</sub>/m&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >50.91</td><td align="center" valign="middle" >50.32</td><td align="center" valign="middle" >50.12</td><td align="center" valign="middle" >49.93</td></tr><tr><td align="center" valign="middle" >Re-combustion methane speed (v<sub>CH4</sub>/m&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >27.90</td><td align="center" valign="middle" >37.20</td><td align="center" valign="middle" >46.50</td></tr><tr><td align="center" valign="middle" >CH<sub>4</sub> volume flow (V<sub>CH4</sub>/m<sup>3</sup>&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >2.86</td><td align="center" valign="middle" >3.82</td><td align="center" valign="middle" >4.77</td></tr><tr><td align="center" valign="middle" >Re-combustion air speed (v<sub>r-c,air</sub>/m&#183;s<sup>−1</sup>)</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >31.35</td><td align="center" valign="middle" >41.80</td><td align="center" valign="middle" >52.25</td></tr></tbody></table></table-wrap><p>is higher than that of case 2 - 4, but lower at the re-combustion zone. The CO and CO<sub>2</sub> volume fraction have an inverse trend, being related to the concentration of O<sub>2</sub>. When O<sub>2</sub> in flue gas decreases, CO increases, but CO<sub>2</sub> decreases. This indicates that the simulation is reasonable. At the re-combustion area, the NO concentration decreases with the rise of CH<sub>4</sub> volume fraction, in that a part of NO react with CO to generate N<sub>2</sub> and CO<sub>2</sub>. At the re-combustion area, the NOx production decreases greatly with the rise of CH<sub>4</sub> re-combustion ratio. Therefore, the productions of NOx at cases 2 - 4 are less than that at case 1. The mean mass concentrations of NOx at furnace outlet are 535.05 mg/m<sup>3</sup>, 497.48 mg/m<sup>3</sup>, 446.16 mg/m<sup>3</sup>, 398.00 mg/m<sup>3</sup> respectively, where the NOx emissions decrease by 7.02%, 16.61% and 25.61%, respectively.</p></sec></sec><sec id="s4"><title>4. Conclusions</title><p>In this work, the numerical models are built to study the influence of different methane re-combustion ratio on the combustion process and the concentration distributions of the flue gas components in a retrofitted coal-fired boiler. The research work shows that methane gas re-combustion can lead to the temperature at primary zone decrease, reducing NOx formation in furnace. The re-combustion of methane gas can produce reduction atmosphere to further reduce NO to N<sub>2</sub>. The NOx concentration at the furnace outlet can be reduced by 7.02%, 16.61% and 25.61% respectively compared to strict coal combustion condition.</p><p>In order to ensure safe operation of boiler and effective reduction of NOx emissions from boiler, it is more reasonable to construct a re-combustion zone with 12.5% methane as re-combustion fuel. It is feasible to retrofit the old units in service to reduce NOx emission according to fuel staging combustion technology.</p></sec><sec id="s5"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s6"><title>Cite this paper</title><p>Zhang, X.T., Gondal, H.A.M., Duan, F.Y., Zhang, W.D., Mu, H.L., Zhang, C.Y. and Wang, A.J. (2020) Numerical Study on NOx Emissions of Methane Re-Combustion in a 600 MWe Coal-Fired Boiler. Energy and Power Engineering, 12, 101-107. https://doi.org/10.4236/epe.2020.123008</p></sec></body><back><ref-list><title>References</title><ref id="scirp.99172-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Wang, L.K., Pereira, N.C. and Hung, Y.T. (2004) Air Pollution Control Engineering: Handbook of Environmental Engineering. Vol. 1. Humana Press Inc., Totowa.</mixed-citation></ref><ref id="scirp.99172-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Martin, M., Robert, D., Julian, W. and Andreas, H. (2017) Boiler Design with Solid-Gaseous Fuel Staging to Reduce NOx Emissions and Optimize Load Flexibility. Chemical Engineering and Technology, 40, 289-297.  
https://doi.org/10.1002/ceat.201600199</mixed-citation></ref><ref id="scirp.99172-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Kuang, M., Zhu, Q.Y., Li, Z.Q. and Zhang, X. (2013) Numerical Investigation on Combustion and NOx Emissions of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging: Effect of the Air Stoichiometric Ratio in the Primary Combustion Zone. Fuel Processing Technology, 109, 32-42.  
https://doi.org/10.1016/j.fuproc.2012.09.035</mixed-citation></ref><ref id="scirp.99172-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Zhou, H.H., Zhang, Z.D., Shao, W.W. and Xiao, Y.H. (2018) Analysis on NOx Emission Characteristics of Natural Gas Fuel-Staged Combustion (NOx). Journal of Propulsion Technology, 39, 1024-1032.</mixed-citation></ref><ref id="scirp.99172-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Liu, H.P. and Dong, J.X. (2007) Intermediate Experimental Study on Low-NOx Combustion Technology for Ultrafine Pulverized Coal Re-Burning. Northeast Electric Power Technology, No. 4, 1-4.</mixed-citation></ref><ref id="scirp.99172-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Yun, S. and Fan, Z. (2018) Catalytic Reduction of NOx by Biomass-Derived Activated Carbon supported Metals. Chinese Journal of Chemical Engineering, 10, 2077-2083. https://doi.org/10.1016/j.cjche.2018.04.019</mixed-citation></ref><ref id="scirp.99172-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, X.T., Li, K.Y., Zhang, C. and Wang, A.J. (2020) Performance Analysis of Biomass Gasification Coupled with a Coal-Fired Boiler System at Various Loads. Waste Management, 105, 84-91. https://doi.org/10.1016/j.wasman.2020.01.039</mixed-citation></ref><ref id="scirp.99172-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Glarborg, P., Kristensen, P.G. and Dam-Johansen, K. (2000) Nitric Oxide Reduction by Non-Hydrocarbon Fuels. Implications for Re-Burning with Gasification Gases. Energy &amp; Fuels, 14, 828-838. https://doi.org/10.1021/ef990186r</mixed-citation></ref><ref id="scirp.99172-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Shi, J.R. and Xu, Y.N. (2011) Three-Dimensional Numerical Simulation of Gas Re-Burning Mixing Characteristics of Coal-Fired Boilers. Boiler Technology, 42, 39-42+47.</mixed-citation></ref><ref id="scirp.99172-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Wu, X.Y. and Song, Q. (2015) Synergetic Effect of Biomass Volatiles on NO Reduction and the Influence of K/Na on It. Fuel, 158, 634-640.  
https://doi.org/10.1016/j.fuel.2015.06.029</mixed-citation></ref><ref id="scirp.99172-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Su, S., Xiang, J. and Sun, L.S. (2009) Study on Re-Burning to Reduce NOx Emissions and Pulverized Coal Burnout Characteristics. Journal of Engineering Thermo-Physics, 30, 1767-1770.</mixed-citation></ref><ref id="scirp.99172-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Lu, H.K. and Yang, W.J. (2010) Experimental Study on the Effect of Sodium Carbonate on Advanced Re-Burning of Methane. Proceedings of the CSEE, 30, 50-55.</mixed-citation></ref></ref-list></back></article>