<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AJAC</journal-id><journal-title-group><journal-title>American Journal of Analytical Chemistry</journal-title></journal-title-group><issn pub-type="epub">2156-8251</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ajac.2020.111001</article-id><article-id pub-id-type="publisher-id">AJAC-97820</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Oxygen Plasma/Bismuth Modified Inkjet Printed Graphene Electrode for the Sensitive Simultaneous Detection of Lead and Cadmium
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Léopoldine</surname><given-names>Sonfack Guenang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Prachi</surname><given-names>Gupta</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Victor</surname><given-names>Costa Basseto</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Milica</surname><given-names>Jovic</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ervice</surname><given-names>Ymélé</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Andreas</surname><given-names>Lesch</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hubert</surname><given-names>Girault</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ignas</surname><given-names>Kenfack Tonlé</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Laboratoired’ Electrochimie Physique et Analytique (LEPA), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland</addr-line></aff><aff id="aff3"><addr-line>Electrochemistry and Chemistry of Materials, Department of Chemistry, University of Dschang, Dschang, Cameroon</addr-line></aff><aff id="aff1"><addr-line>Inorganic Chemistry Laboratory, Department of Chemistry, University of Buea, Buea, Cameroon</addr-line></aff><pub-date pub-type="epub"><day>13</day><month>01</month><year>2020</year></pub-date><volume>11</volume><issue>01</issue><fpage>1</fpage><lpage>14</lpage><history><date date-type="received"><day>22,</day>	<month>October</month>	<year>2019</year></date><date date-type="rev-recd"><day>11,</day>	<month>January</month>	<year>2020</year>	</date><date date-type="accepted"><day>14,</day>	<month>January</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this work, a simple procedure for the preparation of an inkjet printed disposable graphene electrode is reported. Commercial graphene ink was printed on a kapton substrate and the resulting electrode was 30 min treated by oxygen plasma, then modified by a bismuth salt. The as prepared electrode was characterized by Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), laser scanning microscopy (LSM) and scanning electron microscopy (SEM) coupled to energy-dispersive X-ray spectroscopy (EDX). The sensing properties of the characterized electrodes were then investigated using cyclic voltammetry and Electrochemical Impedance Spectroscopy (EIS). Afterwards, these electrodes were exploited in a comparative way for the electroanalysis of Cadmium(II) and Lead(II) ions. An increase in the electrode sensitivity due to its modification and to the presence of bismuth was observed. Some preliminary experiments based on stripping square wave voltammetry highlighted the interest of using the proposed disposable inkjet printed electrodes for the electrochemical detection of heavy metals in tap water.
 
</p></abstract><kwd-group><kwd>Inkjet Printing Technology</kwd><kwd> Disposable Printed Graphene Electrode</kwd><kwd> Heavy Metals</kwd><kwd> Stripping Voltammetry</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Environmental pollution constitutes a daily and emergent concern for both the developing and developed countries due to industrialization, economic development, and high population growth. In fact, various toxic organic and inorganic substances are frequently introduced into the environment from either natural or anthropogenic sources [<xref ref-type="bibr" rid="scirp.97820-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref2">2</xref>]. The most common inorganic environmental pollutants are heavy metals, defined to be metallic elements with a density greater than 5 g&#183;cm<sup>−</sup><sup>3</sup> [<xref ref-type="bibr" rid="scirp.97820-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref3">3</xref>], and atomic numbers greater than 20 [<xref ref-type="bibr" rid="scirp.97820-ref4">4</xref>]. Heavy metals also include metalloids, such as arsenic, that are able to bring toxicity at a low level of exposure [<xref ref-type="bibr" rid="scirp.97820-ref5">5</xref>]. Lead and cadmium are among the ten chemicals identified by the WHO as major public health concern [<xref ref-type="bibr" rid="scirp.97820-ref6">6</xref>]. They are released into the environment from painting activities, and from the manufacturing and recycling of batteries [<xref ref-type="bibr" rid="scirp.97820-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref8">8</xref>]. Lead is classified as a probable human carcinogen by the International Agency for Research on Cancer (IARC) [<xref ref-type="bibr" rid="scirp.97820-ref8">8</xref>], while cadmium has also been identified as a human carcinogen [<xref ref-type="bibr" rid="scirp.97820-ref9">9</xref>]. The WHO set permissible limits of lead and cadmium concentration in drinking water as 0.01 mg&#183;L<sup>−1</sup> and 0.003 mg&#183;L<sup>−1</sup>, respectively [<xref ref-type="bibr" rid="scirp.97820-ref9">9</xref>].</p><p>To monitor or quantify these toxic heavy metals, several methods are commonly used, that include atomic absorption spectrometry (AAS), inductively coupled plasma mass spectrometry (ICP-MS) and anodic stripping voltammetry (ASV). The spectroscopic methods (AAS and ICP-MS) require a well-equipped laboratory infrastructure, tedious sample preparation, skilled manpower, and high maintenance costs. At the opposite, electrochemical methods like ASV are cheaper, sensitive, and do not require in most cases sample pretreatment [<xref ref-type="bibr" rid="scirp.97820-ref10">10</xref>] - [<xref ref-type="bibr" rid="scirp.97820-ref15">15</xref>]. Several solid electrodes or chemically modified electrodes have been exploited in the electroanalysis of heavy metals. For the few past years, graphene materials have attracted a lot of attention due to their large theoretical surface area (2630 m<sup>2</sup>&#183;g<sup>−1</sup>) [<xref ref-type="bibr" rid="scirp.97820-ref16">16</xref>] ; very high electrical and thermal conductivity (&gt;3000 W&#183;mK<sup>−1</sup>); strong mechanical strength (1 TPa) and their gas impermeability [<xref ref-type="bibr" rid="scirp.97820-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref19">19</xref>] and low production cost. Due to these excellent physical and chemical properties, graphene has become an interesting alternative for the development of electrical devices [<xref ref-type="bibr" rid="scirp.97820-ref20">20</xref>] and electrochemical sensors [<xref ref-type="bibr" rid="scirp.97820-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref24">24</xref>]. Graphene is a single layer or few layers of graphite with sp<sup>2</sup> carbon atoms packed in a honeycomb crystal lattice [<xref ref-type="bibr" rid="scirp.97820-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref26">26</xref>]. It was first isolated in 2004 by Novoselov et al. [<xref ref-type="bibr" rid="scirp.97820-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref28">28</xref>] and due to the presence of the sp<sup>2</sup>-like planes and the edge defects that are more exposed, the graphene-based electrochemical sensors present a better performance compared to glassy carbon, graphite and even carbon nanotubes sensors [<xref ref-type="bibr" rid="scirp.97820-ref29">29</xref>]. Within the existing techniques of graphene modified electrodes, the electrochemical reduction technique of graphene or graphene oxide on glassy carbon electrode is the most used for the fabrication of sensors [<xref ref-type="bibr" rid="scirp.97820-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref31">31</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref32">32</xref>]. This technique is slow and can’t be used for electrodes batch production, while a more precise technique is required to obtain highly reproducible and multiple disposable sensors [<xref ref-type="bibr" rid="scirp.97820-ref33">33</xref>]. Nowadays, inkjet printing of functional materials becomes a very promising mask-free microfabrication technique, that allows a precise deposition of conductive organic and inorganic materials such as carbon nanotube, silver and gold [<xref ref-type="bibr" rid="scirp.97820-ref33">33</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref34">34</xref>]. The materials are printed with a certain shape and dimension directly on a substrate [<xref ref-type="bibr" rid="scirp.97820-ref35">35</xref>]. Inkjet printing technology offers the advantage that, it requires absolutely no prefabrication of template as is the case with the other printing methods such as transfer printing, contact printing and aerosol printing [<xref ref-type="bibr" rid="scirp.97820-ref36">36</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref37">37</xref>]. Some authors have introduced the fabrication of graphene inkjet printed electrodes and their electroanalytical applications. Dong et al. [<xref ref-type="bibr" rid="scirp.97820-ref38">38</xref>] reported the development of a new type of sandwich structured ionic liquid carbon nanotube graphene film (IL-CNT-GF) synthesized by a facile and effective inkjet printing method for the in situ electrochemical detection of Bi<sup>3+</sup>, Pb<sup>2+</sup> and Cd<sup>2+</sup> in environmental samples. They showed that IL and CNT modified inkjet printed electrode possesses a good sensing performance, a high sensitivity and can detect Cd<sup>2+</sup> and Pb<sup>2+</sup> down to 10<sup>−10</sup> M. To date, stand-alone inkjet printed graphene electrodes with proper electrochemical behavior as amperometric sensors are scarce in the literature. We were therefore interested in this work in preparing and characterizing a disposable graphene inkjet printed electrode (IJPGE) as a potential analytical tool for the detection of lead and cadmium. The disposable electrode was obtained by firstly producing a series of graphene-based inkjet printed electrodes, identified as IJPGE. Secondly, an oxygen plasma treatment was applied on the active surface area of the IJPGE in order to activate the electrode surface. Finally, a bismuth solution was drop-coated on the oxygenated-IJPGE surface, followed by stabilization using electrochemical oxidation. The prepared electrodes were then successfully used for the simultaneous detection of cadmium and lead ions in acidic solution. Before their exploitation in electrochemical tests, the electrodes were characterized by Laser Scanning Microscopy (LSM), Raman spectroscopy, Scanning Electron Microscopy (SEM) coupled to Energy Dispersive X-ray (EDX), X-ray Photoelectron Spectroscopy (XPS) and Electrochemical Impedance Spectroscopy (EIS).</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Material and Reagents</title><p>An inkjet-printable graphene dispersion and ethyl cellulose (solid content 2.4 wt. %) in cyclohexanone and terpineol were obtained from Sigma Aldrich (originally synthesized by the Mark Hersam group at Northwestern University, USA), while the UV curable dielectric ink EMD 6201 was purchased from SunChemical. Kapton HN(R) (polyimide PI, 125 &#181;m thickness) was obtained from Goodfellow and served as substrate. Bi(NO<sub>3</sub>)<sub>3</sub>, Cd(OAc)<sub>2</sub> and Pb(OAc)<sub>2</sub> were also from Sigma-Aldrich and different electrolytes of HNO<sub>3</sub>, HCl and acetate buffer (prepared from 0.2 M CH<sub>3</sub>COOH and 0.2 M CH<sub>3</sub>COOK) were prepared with deionized water.</p><p>Two inkjet printing platforms were used in this work to fabricate the thin film graphene electrodes:</p><p>1) TheDMP-2850 material deposition printer from Fujifilm Dimatix was employed to deposit four inkjet printed layers of the graphene dispersion;</p><p>2) The X-Serie Ceraprinter from Ceradrop was used to simultaneously print and photopolymerized with an integrated UV LED (FireEdge FE300 380 - 420 nm; Phoseon Technology) the UV curable ink as insulating material in order to define accurately the electrode area and to insulate partially the graphene patterns used as electronic traces.</p><p>Disposable DimatixDMC-11610 cartridges containing 16 individually addressable nozzles and generating nominally 10 pL droplets were used in both machines. All printing parameters, such as the voltage pulse for the piezoelectric actuation inside the nozzles, jetting frequency, droplet falling speed, overlapping distance of adjacent droplets and substrate temperature were optimized for each printed layer. After the printing of the graphene ink, the patterns were thermally cured for 1 h in a furnace at 400˚C. The insulation layer was deposited as a frame around the graphene pattern to create a squared working electrode area of theoretically 1 mm<sup>2</sup> as shown in Scheme 1.</p><p>A potentiostat (&#181;-Autolab, Holland) running with NOVA software was used for electrochemical measurements. A standard single compartment three-electrode cell was used with an Ag/AgCl/1 M KCl reference electrode (LEPA fabrication, Switzerland) and a coiled platinum wire electrode as counter electrode. The working electrode was an inkjet printed disposable graphene electrode. Stripping square wave voltammetry experiments for the electroanalysis of lead and cadmium were carried out without degassing the supporting electrolyte solution. A potentiostat (Palmsens, Holland) running with PS Trace software was used for the characterization of electrodes by EIS. Thus, a standard single compartment three electrodes cell was used with a commercial Ag/AgCl reference and an inox bar as counter electrode. The working electrodes were the three different graphene-based electrodes prepared in this work. Laser Scanning Microscopy (LSM) was taken with the Keyence VK-8700 microscope. The Scanning Electron Microscopy images (SEM, FEI Teneo) were provided by a Quanta 3D FEG 200/600 equipment supplied by FEI Company. Energy Dispersive X-ray spectroscopy (EDX) was used to characterize the graphene patterns before and after the oxygen plasma treatment.</p></sec><sec id="s2_2"><title>2.2. Electrode Modification Procedure</title><p>On a 4 layers (4L) inkjet printed graphene electrode, treated with an oxygen</p><disp-formula id="scirp.97820-formula1"><graphic  xlink:href="//html.scirp.org/file/1-2201871x2.png"  xlink:type="simple"/></disp-formula><p>Scheme 1. A picture of the inkjet-printed disposable graphene electrode (IPGE).</p><p>plasma (for 30 min under 0.6 mbar), 1 &#181;L drop of Bi (III) was deposited and dried at room temperature for few minutes. The electrode was then gently rinsed with deionized water to remove the non-adsorbed bismuth cations. Stripping square wave voltammetry in acetate buffer (at pH 4.8) was performed in order to confirm the coating of bismuth on the oxygen treated electrode surface. After several scans, the electrode was removed, rinsed, dried and the stripping step was restarted in a fresh acetate buffer solution. The stabilization of the electrode was achieved and it was ready for simultaneous stripping voltammetry analysis of cadmium and lead.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Characterization of Inkjet Graphene Electrode (GE) and Its Oxygen Treated Counterpart (O<sub>2</sub>-GE) by Raman Spectroscopy</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref> shows the Raman spectra of GE (a) and O<sub>2</sub>-GE (b). On <xref ref-type="fig" rid="fig1">Figure 1</xref>(a) related to the GE, numerous peaks were observed and attributed to the characteristic peak of graphene (sp<sup>2</sup> peak of graphite), namely G at 1600 cm<sup>−1</sup>. Beside this peak, D and D’ signals were obtained, at 1300 cm<sup>−1</sup> and 1610 cm<sup>−1</sup> respectively while a 2D peak was noticed at 2700 cm<sup>−1</sup>. The presence of D and D’ shows that the used commercial ink contains defect or disorder [<xref ref-type="bibr" rid="scirp.97820-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref31">31</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref32">32</xref>]. The 2D band (also known as G’ or G band) is used to determine the number of graphene layer [<xref ref-type="bibr" rid="scirp.97820-ref31">31</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref33">33</xref>] : the ratio I<sub>G</sub>/I<sub>2D</sub> with a value of 4 indicates that 4 graphene layers are printed on the substrate. After 30 min of oxygen plasma treatment (<xref ref-type="fig" rid="fig1">Figure 1</xref>(b)), some changes were observed: the decrease of D and D’ peaks intensities due to the decrease of defects (impurities). Yet, the treatment by oxygen plasma cleaned the surface of graphene [<xref ref-type="bibr" rid="scirp.97820-ref34">34</xref>]. This decrease also led to a reduction of the amount of non-sp<sup>2</sup> bonding [<xref ref-type="bibr" rid="scirp.97820-ref35">35</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref36">36</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref37">37</xref>] and to an increase of sp<sup>2</sup> bonding (increase of graphene activated site). The increase in G and 2D peak intensity leading to a I<sub>G</sub>/I<sub>2D</sub> ratio of 3 indicated a reduction of the number of graphene layers</p><p>from 4 (theoretically printed) to 3 after oxygen treatment; this was confirmed by the shifting of 2D band to lower wavenumber.</p><p>This was attributed to oxygen plasma treatment which progressively removes graphene in a layer by layer fashion [<xref ref-type="bibr" rid="scirp.97820-ref37">37</xref>]. Also, a decrease of the I<sub>D</sub>/I<sub>G</sub> ratio to 0.1 indicated the reduction of defect density or disorder on the electrode surface leading to an increasing graphitic nature of graphene layers, correlated with the removal of the printed insulator [<xref ref-type="bibr" rid="scirp.97820-ref38">38</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref39">39</xref>] [<xref ref-type="bibr" rid="scirp.97820-ref40">40</xref>]. Finally, the oxygen treatment of the electrode led to an increase of graphene activated sites on the inkjet printed surface. <sup> </sup></p></sec><sec id="s3_2"><title>3.2. Morphologic Characterization of GE, O<sub>2</sub>-GE and Bi-O<sub>2</sub>-GE</title><sec id="s3_2_1"><title>3.2.1. Laser Scanning Microscopy (LSM)</title><p>The LSM images of the electrodes are shown on <xref ref-type="fig" rid="fig2">Figure 2</xref>. <xref ref-type="fig" rid="fig2">Figure 2</xref>(a) presents the picture of the bare GE: one can observe that the graphene layer printed on the surface of Kapton substrate is uniform. After O<sub>2</sub>-plasma treatment (<xref ref-type="fig" rid="fig2">Figure 2</xref>(b)), the surface became dark due to the treatment which led to the etching and the removal of residual photoresists on this electrode surface [<xref ref-type="bibr" rid="scirp.97820-ref34">34</xref>]. The dark appearance of the surface is due to the high quantity of oxygen deposited on the electrode within the long oxygenation time (30 min) and the high plasma power used. This observation is in agreement with a previous work by Solis et al. [<xref ref-type="bibr" rid="scirp.97820-ref41">41</xref>]. Also, the appearance of a long strip at the center of the surface and many white points all over the electrode surface were observed. According to Zhang et al. [<xref ref-type="bibr" rid="scirp.97820-ref42">42</xref>], the long strip may represent the active sites (defects) density while the white points are due to pits and holes produced by the oxygen plasma treatment (this was confirmed by the SEM spectra). However, this long strip can lead to an increase in the electronic transfer on the treated oxygenated inkjet printed electrode [<xref ref-type="bibr" rid="scirp.97820-ref42">42</xref>]. The deposition of the bismuth (<xref ref-type="fig" rid="fig2">Figure 2</xref>(c)) also changes this appearance by making it become clearer. This can be due to the removal of the excess bismuth ions by washing. It was also observed that the white points present on <xref ref-type="fig" rid="fig2">Figure 2</xref>(b) become dark, probably due to bismuth ions that occupied different active sites.</p></sec><sec id="s3_2_2"><title>3.2.2. Scanning Electron Microscopy (SEM)</title><p><xref ref-type="fig" rid="fig3">Figure 3</xref> represents the SEM images of GE (a), O<sub>2</sub>-plasma-GE (b) and Bi-drop-O<sub>2</sub>-plasma-GE (c). From these figures, a difference of morphology was noticed. The pits and holes of <xref ref-type="fig" rid="fig3">Figure 3</xref>(b) are due to the high temperature oxidative exposure (long time exposition under oxygen) [<xref ref-type="bibr" rid="scirp.97820-ref43">43</xref>].</p><p>This can also be explained by the oxidation of the π-network of the graphene electrode [<xref ref-type="bibr" rid="scirp.97820-ref44">44</xref>]. The slight morphology difference observed within the O<sub>2</sub>-plasma-GE and the Bi-O<sub>2</sub>-plasma-GE can be explained by the washing of the bismuth salt on the graphene sheet surface, leading to the production of more holes (<xref ref-type="fig" rid="fig3">Figure 3</xref>(c)).</p></sec><sec id="s3_2_3"><title>3.2.3. Energy Dispersive X-Ray Spectroscopy (EDX)</title><p>EDX spectrum of graphene (a), O<sub>2</sub>-graphene (c) and Bi-O<sub>2</sub>-graphene (b) electrodes are shown on <xref ref-type="fig" rid="fig4">Figure 4</xref>. The peaks of carbon and oxygen with different heights are well observed on each electrode.</p><p>The observed differences in carbon peak intensities on these curves are due to the O<sub>2</sub> plasma treatment that removes one layer of the printed graphene [<xref ref-type="bibr" rid="scirp.97820-ref34">34</xref>]. For oxygen peaks, the difference is attributed to the deposition of this element</p><p>on the surface of graphene during the treatment. The presence of bismuth on the surface of graphene electrode in <xref ref-type="fig" rid="fig4">Figure 4</xref>(b) is revealed by bismuth. The phosphorus peak may arise from the ink as impurities.</p></sec><sec id="s3_2_4"><title>3.2.4. Electrochemical Characterization of Electrodes</title><p>Cyclic Voltammetry analysis was used to evaluate the electron transfer properties of carbon material on various prepared electrodes in the presence of [Fe(CN)<sub>6</sub>]<sup>3−</sup> ions and the results are presented in <xref ref-type="fig" rid="fig5">Figure 5</xref>. The GE exhibited a well-defined redox peak (<xref ref-type="fig" rid="fig5">Figure 5</xref>(a)) in the studied potential window. The observed redox peak pair demonstrated a favorable direct electron transfer between the inkjet printed GE and the redox species. After oxygen treatment, the electrode displayed a higher signal than that registered on the GE (<xref ref-type="fig" rid="fig5">Figure 5</xref>(b)). This result should be due to the treatment that increased the effective surface area of the GE, thereby offering a faster electron transfer rate. After dropping 1 μL of Bi3+ solution on the surface of O<sub>2</sub>-plasma graphene, the peak slightly increased and shifted to more positive potentials (<xref ref-type="fig" rid="fig5">Figure 5</xref>(c)).</p></sec></sec><sec id="s3_3"><title>3.3. Preliminary Investigations on Prepared Electrodes for Heavy Metal Ions Detection</title><p>Upon characterization, the electrodes prepared in this work were evaluated for the electrochemical detection of cadmium and lead ions by means of square wave voltammetry (SWV). The following optimized parameters (results not shown) were used: deposition time: 210 s; deposition potential: −1.1 V (vs Ag/AgCl); electrolyte: 0.1 M acetate buffer at pH 4.8; frequency: 25 Hz; amplitude: 25 mV and potential step: 10 mV.</p><p>As shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>, all studied electrodes displayed signals for the investigated ionic species, the bare GE being the least sensitive (curve a). However, the amperometric signal was more pronounced on Bi-O<sub>2</sub>-plasma GE for Pb<sup>2+</sup> ions</p><p>(curve c) although a shoulder due to the formation of PbO was observed around −0.45 V, while the tendency was reversed for O<sub>2</sub>-plasma GE (curve b) as the codeposition of Bi<sup>3+</sup> and Cd<sup>2+</sup> was favored.</p><p>Overall, the oxygen treatment led to an increase of the peak current of lead and cadmium, and the bismuth film contributed to increase the sensitivity of the inkjet printed graphene electrode and the formation of sharp and well-defined peaks by avoiding the formation of intermetallic instable compounds such as PbO.</p></sec><sec id="s3_4"><title>3.4. Calibration Curves, Interference Study and Analytical Application</title><p>In further experiments, the Bi-O<sub>2</sub>-plasma GE sensor was applied in the quantification, under optimized conditions, of Cd<sup>2+</sup> and Pb<sup>2+</sup> ions in a real water sample. Beforehand, the calibration curves were plotted upon variation of the concentration of both analytes in 0.1 M acetate buffer (at pH 4.8) containing varied amounts of Pb<sup>2+</sup> and Cd<sup>2+</sup> ions as shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>(a). As one can observe, an increase in the sensor response was obtained when the concentration of the studied ions was varied in the range between 0.1 M and 6 &#215; 10<sup>−</sup><sup>8</sup> M.</p><p>The dependence of the peak current on the concentration of these analytes (<xref ref-type="fig" rid="fig7">Figure 7</xref>(b)) followed the equations Ip(A) = 155 [Cd<sup>2+</sup>] (M) − 5.6 &#215; 10<sup>−</sup><sup>7</sup> and Ip(A) = 198 [Pb<sup>2+</sup>] (M) − 1.38 &#215; 10<sup>−</sup><sup>6</sup>, with correlation coefficients of 0.997 and 0.994 respectively. The detection limits (DL) calculated as DL = 3S<sub>b</sub>/m [<xref ref-type="bibr" rid="scirp.97820-ref45">45</xref>] (where S<sub>b</sub> is the standard deviation of the blank and m the slope of the linear regression equation) were estimated to be 7.1 &#215; 10<sup>−</sup><sup>9</sup> mol&#183;L<sup>-1</sup> and 5.3 &#215; 10<sup>−</sup><sup>10</sup> mol&#183;L<sup>−</sup><sup>1</sup> for the Pb<sup>2+</sup> and Cd<sup>2+</sup> ions, respectively, on the basis of signal-to-noise ratio equal to 3.</p><p>Before applying the Bi-O<sub>2</sub>-plasma GEsensor to a real sample analysis, its selectivity was studied by adding to the supporting electrolyte, containing 6 &#215; 10<sup>−</sup><sup>8</sup> M of both Cd<sup>2+</sup> and Pb<sup>2+</sup> ions, the following species: Zn<sup>2+</sup>, Fe<sup>2+</sup>, Cr<sup>3+</sup>, Ca<sup>2+</sup>, Cu<sup>2+</sup>, Ni<sup>2+</sup>, Mg<sup>2+</sup>, K<sup>+</sup> and Al<sup>3+</sup> ions. The concentration of these interfering ions was set to be 1, 10, 50 and 100-fold higher than that of Cd<sup>2+</sup> and Pb<sup>2+</sup> ions. For the results obtained in the last case, a real influence of added ions was noticed as shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p><p>The analysis of these results showed that the presence of Zn<sup>2+</sup>, Fe<sup>2+</sup> Cr<sup>3+</sup> and Cu<sup>2+</sup> ions influences the voltammetric signals of both Cd<sup>2+</sup> and Pb<sup>2+</sup> ions. A decrease in peak current intensities of the target ions (1.4% to 31.5%) except in the case of Cu<sup>2+</sup> ions where a total disappearance of Cd<sup>2+</sup> and Pb<sup>2+</sup> ions responses was observed. The effect of the interfering ions on the signal of Cd<sup>2+</sup> and Pb<sup>2+</sup> ions increased in the following order: Zn<sup>2+</sup> &lt; Fe<sup>2+</sup> &lt; Cr<sup>3+</sup> &lt; Cu<sup>2+</sup>, therefore preventing the exploitation of the proposed sensor in solutions expected to contain Cu<sup>2+</sup> ions.</p><p>Since interference was observed for low concentrations of added ions (100-fold Cd<sup>2+</sup> or Pb<sup>2+</sup> concentration), the proposed sensor was finally applied to detect the investigated analytes in a laboratory tap water sample. Thus, 10 mL of 0.1 M acetate buffer and 10 mL of tap and the blank were recorded using the optimized parameters established so far in this study which showed that the sample already contained lead and cadmium. Then the solution was spiked with 8 &#215; 10<sup>−</sup><sup>8</sup> mol&#183;L<sup>−</sup><sup>1</sup> of Cd<sup>2+</sup> and Pb<sup>2+</sup> ions and the recovery rate was in good agreement with the added concentration, taking into account the presence of the investigated analytes and that of Cu<sup>2+</sup> found to be the most interfering species.</p></sec></sec><sec id="s4"><title>4. Conclusion</title><p>This work was devoted to the preparation of a disposable graphene electrode, which was obtained by printing a graphene ink on an inert Kapton substrate, followed by treatment using oxygen plasma and a bismuth salt. The electrode was characterized by various physic-chemical and electrochemical techniques, and then applied to the detection of Cd<sup>2+</sup> and Pb<sup>2+</sup> ions by square wave voltammetry. It was found that its sensitivity is greatly dependent on the treatment steps and on the parameters involved in the detection step by square wave voltammetry. In spite of rather high interference of some ions in the analytical application of the proposed sensor, it was shown that the analytical method developed here is simple and sensitive, and could serve as a promising tool for the monitoring of heavy metals in various polluted solutions.</p></sec><sec id="s5"><title>Acknowledgements</title><p>LSG grateful acknowledges the support of the EPFL (Switzerland) for all facilities, as well as the Ministry of Higher Education (Cameroon) for a travel grant.</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare that they have no competing interests.</p></sec><sec id="s7"><title>Cite this paper</title><p>Guenang, L.S., Gupta, P., Basseto, V.C., Jovic, M., Ym&#233;l&#233;, E., Lesch, A., Girault, H. and Tonl&#233;, I.K. (2020) Oxygen Plasma/Bismuth Modified Inkjet Printed Graphene Electrode for the Sensitive Simultaneous Detection of Lead and Cadmium. American Journal of Analytical Chemistry, 11, 1-14. https://doi.org/10.4236/ajac.2020.111001</p></sec></body><back><ref-list><title>References</title><ref id="scirp.97820-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Samiey, B., Cheng, C.H. and Wu, J. (2014) Organic-Inorganic Hybrid Polymers as Adsorbents for Removal of Heavy Metal Ions from Solutions: A Review. Journal of Materials, 7, 673-726. https://doi.org/10.3390/ma7020673</mixed-citation></ref><ref id="scirp.97820-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Jaishankar, M., Tseten, T., Anbalagan, N., Mathew, B.B. and Beeregowda, K.N. (2014) Toxicity, Mechanism and Health Effects of Some Heavy Metals. Interdisciplinary Toxicology, 7, 60-72. https://doi.org/10.2478/intox-2014-0009</mixed-citation></ref><ref id="scirp.97820-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Jarup, L. (2003) Hazards of Heavy Metals Contamination. British Medical Bulletin, 68, 167-182. https://doi.org/10.1093/bmb/ldg032</mixed-citation></ref><ref id="scirp.97820-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Lu, F. and Astruc, D. (2018) Nanomaterials for Removal of Toxic Elements from Water. Coordination Chemistry Review, 356, 147-164. https://doi.org/10.1016/j.ccr.2017.11.003</mixed-citation></ref><ref id="scirp.97820-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Fan, C.S., Liou, S.Y.H. and Hou, C.H. (2017) Capacitive Deionization of Arsenic-Contaminated Groundwater in a Single-Pass Mode. Chemosphere, 184, 924-931. https://doi.org/10.1016/j.chemosphere.2017.06.068</mixed-citation></ref><ref id="scirp.97820-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">World Health Organization (WHO) (2010). http://www.who.int/about/licensing/copyright_form/en/index.html</mixed-citation></ref><ref id="scirp.97820-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Kaplan, I.O., Ince, M., Yonten, V. and Goksu, A. (2017) A Food Waste Utilization Study for Removing Lead (II) from Drinks. Food Chemistry, 214, 637-643. https://doi.org/10.1016/j.foodchem.2016.07.117</mixed-citation></ref><ref id="scirp.97820-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Gottesfeld, P. and Pokhrel, A.K. (2011) Review: Lead Exposure in Battery Manufacturing and Recycling in Developing Countries and among Children in Nearby Communities. Journal of Occupational and Environmental Hygiene, 8, 520-532. https://doi.org/10.1080/15459624.2011.601710</mixed-citation></ref><ref id="scirp.97820-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Joseph, P. (2009) Mechanisms of Cadmium Carcinogenesis. Toxicology and Applied Pharmacology, 238, 272-279. https://doi.org/10.1016/j.taap.2009.01.011</mixed-citation></ref><ref id="scirp.97820-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Bansod, B., Kumar, T., Thakur, R., Rana, S. and Singh, I. (2017) A Review on Various Electrochemical Techniques for Heavy Metal Ions Detection with Different Sensing Platforms. Biosensors and Bioelectronics, 94, 443-455. https://doi.org/10.1016/j.bios.2017.03.031</mixed-citation></ref><ref id="scirp.97820-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">World Health Organization (WHO) Geneva, Switzerland (2011). http://www.who.int/about/licensing/copyright_form/en/index.html</mixed-citation></ref><ref id="scirp.97820-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Sánchez, J., Butter, B., Rivas, B.L., Basáez, L. and Santander, P. (2015) Electrochemical Oxidation and Removal of Arsenic Using Water-Soluble Polymers. Journal of Applied Electrochemistry, 45, 151-159. https://doi.org/10.1007/s10800-014-0785-9</mixed-citation></ref><ref id="scirp.97820-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Abiman, P., Wildgoose, G.G., Crossley, A. and Compton, R.G. (2009) Quantitative Studies of Metal Ion Adsorption on a Chemically Modified Carbon Surface: Adsorption of Cd (II) and Hg (II) on Glutathione Modified Carbon. Electroanalysis, 21, 897-903. https://doi.org/10.1002/elan.200804519</mixed-citation></ref><ref id="scirp.97820-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Abiman, P., Wildgoose, G.G., Crossley, A. and Compton, R.G. (2008) Removal of Palladium Ions from Aqueous Systems by Chemically Modified Cysteine Carbon Powder. Journal of Materials Chemistry, 18, 3948-3953. https://doi.org/10.1039/b805804k</mixed-citation></ref><ref id="scirp.97820-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Xiao, L., Wildgoose, G.G., Crossley, A., Knight, R., Jones, J.H. and Compton, R.G. (2006) Removal of Toxic Metal-Ion Pollutants from Water by Using Chemically Modified Carbon Powders. Chemistry: An Asian Journal, 1, 614-622. https://doi.org/10.1002/asia.200600136</mixed-citation></ref><ref id="scirp.97820-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, Y., Murali, S., Cai, W., et al. (2010) Graphene and Graphene Oxide: Synthesis, Properties and Applications. Advanced Materials, 22, 3906-3924. https://doi.org/10.1002/adma.201001068</mixed-citation></ref><ref id="scirp.97820-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Lee, S., Bong, S., Ha, J., Kwak, M., Park, S.-K. and Piao, Y. (2015) Electrochemical Deposition of Bismuth on Activated Graphene-Nafion Composite for Anodic Stripping Voltammetric Determination of Trace Heavy Metals. Sensors and Actuators B, 215, 62-69. https://doi.org/10.1016/j.snb.2015.03.032</mixed-citation></ref><ref id="scirp.97820-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Ke, Q. and Wang, J. (2016) Graphene-Based Materials for Supercapacitor Electrodes: A Review. Journal Materiomics, 2, 37-54. https://doi.org/10.1016/j.jmat.2016.01.001</mixed-citation></ref><ref id="scirp.97820-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Tan, L.L., Chai, S.P. and Mohamed, A.R. (2012) Synthesis and Applications of Graphene-Based TiO2 Photocatalysts. Chemistry and Sustainability Chemistry, 5, 1868-1882. https://doi.org/10.1002/cssc.201200480</mixed-citation></ref><ref id="scirp.97820-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Novoselav, K.S., Fal’ko, V.I., Colombo, L., Gellert, P.R., Schwab, M.G. and Kim, K. (2012) A Roadmap for Graphene. Nature, 190, 192-200. https://doi.org/10.1038/nature11458</mixed-citation></ref><ref id="scirp.97820-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Ratinac, K.R., Yang, W., Gooding, J.J., Thordarson, P. and Braet, F. (2011) Graphene and Related Materials in Electrochemical Sensing. Electroanalysis, 23, 803-826. https://doi.org/10.1002/elan.201000545</mixed-citation></ref><ref id="scirp.97820-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Yang, W., Ratinac, K.R., Ringer, S.P., Thordarson, P., Gooding, J.J. and Braet, F. (2010) Carbon Nanomaterials in Biosensors: Should You Use Nanotube or Graphene? Angewandte Chemie International Edition, 49, 2114-2138. https://doi.org/10.1002/anie.200903463</mixed-citation></ref><ref id="scirp.97820-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Shan, C., Yang, H., Song, J., Han, D., Ivaska, A. and Niu, L. (2009) Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene. Analytical Chemistry, 81, 2378-2382. https://doi.org/10.1021/ac802193c</mixed-citation></ref><ref id="scirp.97820-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Kuila, T., Bose, S., Khanra, P., Mishra, A.K., Kim, N.H. and Lee, J.H. (2011) Recent Advances in Graphene-Based Biosensors. Biosensors and Bioelectronics, 26, 4637-4648. https://doi.org/10.1016/j.bios.2011.05.039</mixed-citation></ref><ref id="scirp.97820-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Liu, Y., Dong, X. and Chen, P. (2012) Biological and Chemical Sensors Based on Graphene Materials. Chemical Society Reviews, 41, 2283-2307. https://doi.org/10.1039/C1CS15270J</mixed-citation></ref><ref id="scirp.97820-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Choi, W., Lahiri, I., Seelaboyina, R. and Kang, Y.S. (2010) Synthesis of Graphene and Its Applications: A Review. Critical Reviews in Solid State and Material Science, 35, 52-71. https://doi.org/10.1080/10408430903505036</mixed-citation></ref><ref id="scirp.97820-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Winnik, J. (2012) Searching for Structural Shifts in Science: Graphene R and D before and after Novoselov et al. (2004). Proceedings of the 17th International Conference on Science and Technology Indicators, Montréal, 1-12. https://www.researchgate.net/publication/263580864</mixed-citation></ref><ref id="scirp.97820-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Novoselov, K.S., Geim, A.K., Morozov, S.V., Jiang, D., Zhang, Y., Dubonos, S.V., Grigorieva, I.V. and Firsov, A.A. (2004) Electric Field Effect in Atomically Thin Carbon Films. Science, 306, 666-669. https://doi.org/10.1126/science.1102896</mixed-citation></ref><ref id="scirp.97820-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Banhart, F., Kotakoski, J. and Krasheninnikov, A.V. (2011) Structural Defects in Graphene. American Chemical Society Nano, 5, 26-41. https://doi.org/10.1021/nn102598m</mixed-citation></ref><ref id="scirp.97820-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Devadas, B., Rajkumar, M., Chen, S.M. and Saraswathi, R. (2012) Electrochemically Reduced Graphene Oxide, Neodymium Hexacyanoferrate Modified Electrode for the Electrochemical Detection of Paracetamol. International Journal of Electrochemical Science, 7, 3339-3349. http://www.electrochemsci.org</mixed-citation></ref><ref id="scirp.97820-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Y., Zhang, M., Wei, Q., Gao, Y., Guo, L., Al-Ghanim, K.A., Mahboob, S. and Zhang, X. (2016) An Easily Fabricated Electrochemical Sensor Based on a Graphene Modified Glassy Carbon Electrode for Determination of Octopamine and Tyramine. Sensors, 16, 535-548. https://doi.org/10.3390/s16040535</mixed-citation></ref><ref id="scirp.97820-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Jian, J.M., Liu, Y.Y., Zhang, Y.L., Guo, X.S. and Cai, Q. (2013) Fast and Sensitive Detection of Pb2+ in Foods Using Disposable Screen-Printed Electrode Modified by Reduced Graphene Oxide. Sensors, 13, 13063-13075. https://doi.org/10.3390/s131013063</mixed-citation></ref><ref id="scirp.97820-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Lesch, A., Cortes-Salazar, F., Prudent, M., Delobel, J., Rastgar, S., Lion, N., Tissot, J.D., Tacchini, P. and Girault, H. (2014) Large Scale Inkjet-Printing of Carbon Nanotubes Electrodes for Antioxidant Assays in Blood Bags. Journal of Electroanalytical Chemistry, 717-718, 61-68. https://doi.org/10.1016/j.jelechem.2013.12.027</mixed-citation></ref><ref id="scirp.97820-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Singh, M., Haverinen, H.M., Dhagat, P. and Jabbour, G.E. (2010) Inkjet Printing-Process and Its Applications. Advanced Materials, 22, 673-685. https://doi.org/10.1002/adma.200901141</mixed-citation></ref><ref id="scirp.97820-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Alves, A.P., Martins, J., Da Silva, H.P., Lourence, A., Fred, A. and Ferreira, H. (2014) Experimental Study and Evaluation of Paper-Based Inkjet Electrodes for ECG Signal Acquisition. Proceedings of the International Conference on Physiological Computing Systems, Vol. 1, 275-281. https://doi.org/10.5220/0004720802750281</mixed-citation></ref><ref id="scirp.97820-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Lawes, S., Riese, A., Sun, Q., Cheng, N. and Sun, X. (2015) Printing Nanostructured Carbon for Energy Storage and Conversion Applications. Carbon, 92 150-176. https://doi.org/10.1016/j.carbon.2015.04.008</mixed-citation></ref><ref id="scirp.97820-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Tortorich, R.P. and Choi, J.W. (2013) Inkjet Printing of Carbon Nanotubes. Nanomaterials, 3, 453-468. https://doi.org/10.3390/nano3030453</mixed-citation></ref><ref id="scirp.97820-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Dong, S., Wang, Z., Asif, M., Wang, H., Yu, Y., Hu, Y., Liu, H. and Xiao, F. (2017) Inkjet Printing Synthesis of Sandwich Structure Ionic Liquid Carbon Nanotube-Graphene Film: Toward Disposable Electrode for Sensitive Heavy Metal Detection in Environmental Water Sample. Industrial and Engineering Chemistry, 56, 1696-1703. https://doi.org/10.1021/acs.iecr.6b04251</mixed-citation></ref><ref id="scirp.97820-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Ardavan, Z., Gwan, H.L., Sung, J.A., Sunwoo, L., Nithin, M., Mauricio, T., Takuya, H., Catalin, R.P., James, H. and Nikhil, K. (2014) Effect of Defects on the Intrinsic Strength and Stiffness of Graphene. Nature Communication, 5, 3186. https://doi.org/10.1038/ncomms4186</mixed-citation></ref><ref id="scirp.97820-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Yang, D.X., et al. (2009) Chemical Analysis of Graphene Oxide Film after Heat and Chemical Treatment by X-Ray Photoelectrons and Micro-Raman Spectroscopy. Carbon, 47, 145-152. https://doi.org/10.1016/j.carbon.2008.09.045</mixed-citation></ref><ref id="scirp.97820-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Solis, F.P., Paredes, J.I., Villar-Rodil, S., Guardia, L., Fernandez-Merino, M.J., Dobrik, G., Biro, L.L.P., Martinez, A. and Tascon, J.M.D. (2011) Global and Local Oxidation Behavior of Reduced Graphene Oxide. Journal of Physical Chemistry C, 115, 7956-7966. https://doi.org/10.1021/jp2003744</mixed-citation></ref><ref id="scirp.97820-ref42"><label>42</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, G.H., et al. (2015) Electrochemistry at Highly Oriented Pyrolytic Graphite (HOPG): Lower Limit for the Kinetics of Outer-Sphere Redox Process and General Implications for Electron Transfer Models. Physical Chemistry Chemical Physics, 17, 11827-11838. https://doi.org/10.1039/C5CP00383K</mixed-citation></ref><ref id="scirp.97820-ref43"><label>43</label><mixed-citation publication-type="other" xlink:type="simple">Nie, Z.H., Wang, H.M., Ma, Y., Kasim, J., Wu, Y.H. and Shen, Z.X. (2008) Tunable Stress and Controlled Thickness Modification in Graphene by Annealing. ACS Nano, 2, 1033-1039. https://doi.org/10.1021/nn800031m</mixed-citation></ref><ref id="scirp.97820-ref44"><label>44</label><mixed-citation publication-type="other" xlink:type="simple">Gokus, T., Nair, R.R., Bonetti, A., B&amp;ouml;hmler, M., Lombardo, A., Novoselav, K.S., Geim, A.K., Ferrari, A.C. and Hartschuh, A. (2009) Making Graphene Luminescent by Oxygen Plasma Treatment. ACS Nano, 3, 3963-3968. https://doi.org/10.1021/nn9012753</mixed-citation></ref><ref id="scirp.97820-ref45"><label>45</label><mixed-citation publication-type="other" xlink:type="simple">Ghoneim, M.M., Hassanein, A.M., Hammam, E. and Beltagi, A.M. (2000) Simultaneous Determination of Cd, Pb, Cu, Sb, Bi, Se, Zn, Mn, Ni, Co and Fe in Water by Differential Pulse Stripping Voltammetry at a Hanging Mercury Drop Electrode. Fresenius Journal of Analytical Chemistry, 367, 378-383. https://doi.org/10.1007/s002160000410</mixed-citation></ref></ref-list></back></article>