<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OALibJ</journal-id><journal-title-group><journal-title>Open Access Library Journal</journal-title></journal-title-group><issn pub-type="epub">2333-9705</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/oalib.1106035</article-id><article-id pub-id-type="publisher-id">OALibJ-97778</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Business&amp;Economics</subject><subject> Chemistry&amp;Materials Science</subject><subject> Computer Science&amp;Communications</subject><subject> Earth&amp;Environmental Sciences</subject><subject> Engineering</subject><subject> Medicine&amp;Healthcare</subject><subject> Physics&amp;Mathematics</subject><subject> Social Sciences&amp;Humanities</subject></subj-group></article-categories><title-group><article-title>
 
 
  Radial Distortion of the Arthroscopic Transtibial Portal: A 2-Dimensional in Vitro Model
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Miodrag</surname><given-names>Vranjes</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Željka</surname><given-names>Cvejić</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nataša</surname><given-names>Todorović</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Zoran</surname><given-names>Gojković</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Vladimir</surname><given-names>Harhaji</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Faculty of Medicine, University of Novi Sad, Novi Sad, Serbia</addr-line></aff><aff id="aff3"><addr-line>Department of Orthopedic Surgery and Traumatology, Clinical Center of Vojvodina, Novi Sad, Serbia</addr-line></aff><aff id="aff2"><addr-line>Faculty of Natural Sciences, Department of Physics, University of Novi Sad, Novi Sad, Serbia</addr-line></aff><pub-date pub-type="epub"><day>02</day><month>01</month><year>2020</year></pub-date><volume>07</volume><issue>01</issue><fpage>1</fpage><lpage>9</lpage><history><date date-type="received"><day>30,</day>	<month>December</month>	<year>2019</year></date><date date-type="rev-recd"><day>7,</day>	<month>January</month>	<year>2020</year>	</date><date date-type="accepted"><day>10,</day>	<month>January</month>	<year>2020</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Purpose: To make the positioning of the anterior cruciate ligament (ACL) transplants as precise as possible, it is necessary to better visualize the foot-print. Identifying anatomic sites is complicated by image distortion inherent in arthroscopy. The standard “Outside-In” ACL reconstruction technique involves drilling a tunnel, i.e. an aperture on the surface of the tibia for the purpose of placing the bone-tendon-bone transplant. This operative technique opens another approach to the inside of the knee, through the tibial plateau (Transtibial-TT). The aim of this manuscript is to assess optimal arthroscopic visibility by calculating radial distortion, arthroscopy insertion positions and different knee bending angles. Methods: We used a standard dot array calibration pattern, an arthroscopic imaging system and Sawbones
   knee models. The standard deviation and relative standard deviation of distances obtained at distortion of the images were calculated. Results: All captured imagines have shown the effect of distortion so called fish-eye view, i.e. the imagines at periphery were more curved and compressed. Conclusion: The least distorted arthroscopic image of the femoral ACL footprint can be obtained when using the TT portal and by bending the knee between 90&#176; and 130&#176;  with a 30&#176;  arthroscope. Also, the best visualization is performed by drilling the tibia under the angle 0&#176;  in the sagittal plane and 23&#176; in the coronal plane in comparison to the tibial surface.
 
</p></abstract><kwd-group><kwd>Transtibial Portal</kwd><kwd> Anterior Cruciate Ligament (ACL)</kwd><kwd> Radial Distortion</kwd><kwd> Ar-throscopy</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>In arthroscopic anterior cruciate ligament (ACL) reconstruction, anatomic accuracy of transplant placement is critical for the clinical success [<xref ref-type="bibr" rid="scirp.97778-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.97778-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.97778-ref3">3</xref>]. The most used portals in knee arthroscopy are the anterolateral (AL) and anteromedial (AM). The AL is mainly used as the viewing portal, and the AM portal is used as the working portal. Some articles advocate the use of AM portal technique with the knee placed in hyperflexion when performing femoral tunnel drilling [<xref ref-type="bibr" rid="scirp.97778-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.97778-ref5">5</xref>]. On the contrary, others perform femoral tunnel drilling through the tibia [<xref ref-type="bibr" rid="scirp.97778-ref6">6</xref>]. To make the positioning of ACL transplants as precise as possible, it is necessary to better visualize the footprint i.e. point of anatomic transplant placement. Inadequate visualization of femoral footprint through the lateral portal can cause surgical error, anterior and more vertical femoral tunnel placement or bending with damage to the telescope [<xref ref-type="bibr" rid="scirp.97778-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.97778-ref8">8</xref>]. Identifying anatomic sites is complicated by image distortion inherent in arthroscopy. Considering this curvature of the image on the monitor, as well as the angle under which the ligament insertion site is observed, it can be concluded that it is difficult to achieve adequate accuracy of observation [<xref ref-type="bibr" rid="scirp.97778-ref9">9</xref>]. The assumption is that if we increase the angle of insertion site observation, or approach 90˚ in relation to the plane formed by the inner side of the external condyle of the femur, we will get visibility that is far better and the mistake in the orientation of the transplant is lower. A greater angle of observation would be possible only through the possible third portal [<xref ref-type="bibr" rid="scirp.97778-ref10">10</xref>]. The standard “Outside-In” ACL reconstruction technique involves drilling a tunnel, i.e. an aperture on the surface of the tibia for the purpose of placing the bone-tone-bone transplant. This operative technique opens another way in the knee, it is a portal through the tibial plateau (Transtibial-TT). The hypothesis is that if introducing optics through this portal, in which the arthroscope can get closer to the site of the ACL footprint, the viewing angle on the plane of the condyle surface is greater, and the curvature of the image would be smaller. Also, we try to find the most adequate tibial drilling angle and the most favorable angle of knee bending during surgery.</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>The arthroscopic imaging system used (Karl Storz, 28731 bwa, Germany 2014) was standard, providing a circular arthroscopic image within 1920 &#215; 1080 pixel display. We used a dot array calibration pattern (<xref ref-type="fig" rid="fig1">Figure 1</xref>). Dots arranged in horizontal and vertical grid lines at square area with a separation of 0.92 mm. The distances between each dot and its four nearest neighbors were equals as in the paper published by Hoshino Y. et al. [<xref ref-type="bibr" rid="scirp.97778-ref11">11</xref>].</p><p>The calibration pattern is placed at the lateral wall of the medial femoral</p><p>condyle in five Sawbones&#174; knee models (Arthrex replaceable bone model of left femur and tibia, SB-1414, Germany 2016) (<xref ref-type="fig" rid="fig2">Figure 2</xref>). All five Sawbones&#174; were drilled under different angles (<xref ref-type="table" rid="table1">Table 1</xref>) with a tibial guide (Karl Storz, Tutlingen, Germany) and were fixed to a custom-made framework with a movable knee flexion angle (<xref ref-type="fig" rid="fig2">Figure 2</xref>). Drilling was performed with a 10 mm drill and the tibial guide was adjusted to 50˚. The guide pin was placed at the inner border of the anterior horn of the lateral meniscus in all Sawbone&#174; models. The extra articular starting point was 1 cm medial to the tuberositas tibiae and 1.5 cm proximal to the upper rim of the pes anserinus projection, 0.5 cm medial to the tuberositas and 2 cm proximal to the pes anserinus, 2 cm medial to the tuberositas and 2 cm proximal to the pes anserinus, 1 cm medial to the tuberositas and 2 cm proximal to the pes anserinus and finally 1.3 cm medial to the tuberositas and 1 cm proximal to the pes anserinus. Using plain radiography of the Sawbones&#174;, different angles of the tibial tunnel were calculated (<xref ref-type="fig" rid="fig3">Figure 3</xref>). The AM and AL portals were simulated by 9 mm screw eyes (Remex doo, Croatia). The AM portal was set 1 cm above the joint line and medial to the line connecting the medial edge of the tibial tuberosity with the medial wall of the intercondylar notch in a bent knee, according to the position described by Zantop et al. [<xref ref-type="bibr" rid="scirp.97778-ref12">12</xref>]. The AL portal was set at 1.5 cm above the joint line and along the line connecting the lateral edge of the tibial tuberosity with the lateral wall of the intercondylar notch.</p><p>The arthroscopic images of the intercondylar lateral wall were taken through the AM, AL or TT portal using five different Sawbones&#174; models and using six different flexion angles. The AM and AL portal were not repeated for every Sawbone&#174; model as was the TT portal. Two examiners (VM and HV) independently took three or more images of the lateral wall for each combination. Care was taken to capture the greatest area of the lateral wall as possible. During the experiment, the position of the arthroscope was about 10 mm from the grid of dots (<xref ref-type="fig" rid="fig4">Figure 4</xref>). The calibration pattern was imaged using 30˚ arthroscope through AM, AL and TT portal at seven different angles (30˚, 50˚, 70˚, 90˚, 110˚ and 130˚) of knee position. We used the 30˚ arthroscopy who is the most used nowadays [<xref ref-type="bibr" rid="scirp.97778-ref13">13</xref>]. The distances for seven selected dots in fifth row and fifth column</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Different tibial knee models and drilling angles in relation to the diaphyseal axis</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >Knee No. 0</th><th align="center" valign="middle" >Knee No. 1</th><th align="center" valign="middle" >Knee No. 2</th><th align="center" valign="middle" >Knee No. 3</th><th align="center" valign="middle" >Knee No. 4</th></tr></thead><tr><td align="center" valign="middle" >Coronal angle [˚]</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >26</td><td align="center" valign="middle" >14</td><td align="center" valign="middle" >16</td></tr><tr><td align="center" valign="middle" >Sagital angle [˚]</td><td align="center" valign="middle" >24</td><td align="center" valign="middle" >23</td><td align="center" valign="middle" >27</td><td align="center" valign="middle" >39</td><td align="center" valign="middle" >22</td></tr></tbody></table></table-wrap><p>in deep and shallow region of calibration pattern and corresponding dot in vertical and horizontal direction were measured. A typical distorted image of the grid is shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>, and it can be noticed that the distances between dots compressed more at the ages of the arthroscopic image and widespread around the distortion center.</p></sec><sec id="s3"><title>3. Results and Discussions</title><p>The image captured by arthroscopic endoscope show radial distortion. Radial distortion is caused by the shape of the lens and, at the same time, is correlated with the focal length. The distortion introduces nonlinear changes in the image. In the case of the positive radial distortion (barrel distortion) areas near the distortion center compressed more. As a consequence, the outer areas of the distorted image look smaller than the real size. Barrel distortion is common for wide angle designed endoscope lens. There are several methods which have been presented for the nonlinear distortion correction [<xref ref-type="bibr" rid="scirp.97778-ref14">14</xref>] - [<xref ref-type="bibr" rid="scirp.97778-ref19">19</xref>]. The even-order polynomial model is one of the frequently used distortion models which enables good enough distortion correction of the endoscopic image. In other words, the relation of coordinates between the real image r<sup>u</sup> and distorted image r<sup>d</sup> could be written as follow:</p><p>r d = r u ( 1 + k 1 r u 2 + k 2 r u 4 + k 3 r u 6 + ⋯ ) (1)</p><p>where r<sup>d</sup> and r<sup>u</sup> can be calculated as follow:</p><p>r d = ( x 2 d − x 1 d ) 2 + ( y 2 d − y 1 d ) 2 and r u = ( x 2 u − x 1 u ) 2 + ( y 2 u − y 1 u ) 2 (2)</p><p>The Descartes coordinates x<sup>u</sup> and y<sup>u</sup> represent coordinates on a planar calibration pattern, and x<sup>d</sup> and y<sup>d</sup> are coordinates of corresponding point in the distorted image. Furthermore, the relation between distorted and undistorted coordinates may be described by r i d = λ ( r i u ) where λ represents distortion ratio and depends on the chosen point with position r<sup>u</sup>. Assuming that the distortion ratio is equal to unity near the center of distortion. Based on the size of the radial distortion of images captured by camera for different insert position (AM, AL and TT) of the arthroscopic instrument and for different knee positions during surgery, the idea of this manuscript is to assess optimal visibility for surgeon during the operation. Before we calculated the distance between two dots for selected columns and rows, we have made two assumptions:</p><p>• The center of distortion is close to the image center.</p><p>• The distortion is circularly symmetric i.e. amount of distortion is dependent only on dot’s distance from the center of distortion.</p><p>Radial distortion in deep and shallow region was calculated using Equation (2). Then we calculated standard deviation and relative standard deviation of distances obtained at the distortion images. This is a more convenient way to deal with the situation of the smallest distortion effects. The relatively standard deviations for radial distortion of three different knee models for different knee angle positions are given in order in <xref ref-type="table" rid="table2">Table 2</xref> and <xref ref-type="table" rid="table3">Table 3</xref>.</p><p>Analyzing the obtained data given in previous tables, i.e. the relative standard deviation for different portal locations with different knee positions, the first thing one notes is that TT portal technique produced the least distortion in arthroscopic image. The second thing which appears is that image distortion is best minimized by a knee position between 110˚ and 130˚. As described by Hoshino et al. [<xref ref-type="bibr" rid="scirp.97778-ref10">10</xref>], when the knee is bent, the posterior margin of the lateral femoral condyle can be seen more clearly due to the weaker and shallow position of the arthroscopic view. So, it would appear that surgeons can identify landmarks more easily by flexing the knee 110˚ then by lower flexion angels. This recognition coincides with our study, although we use another portal. On the contrary, the same paper recommended to use the 90˚ knee flexion angle when determining femoral tunnel placement, but by using the AM portal. According to Hoshino et al. [<xref ref-type="bibr" rid="scirp.97778-ref9">9</xref>] it appears that image distortion is best minimized by a position in which the line-of-sight of the arthroscope is directly perpendicular to the image. In consideration of their findings, surgeons should position the target in the center of the image whenever possible and use a straight viewing angle [<xref ref-type="bibr" rid="scirp.97778-ref9">9</xref>]. Also, the authors outlined that the 0˚ lens angle creates the least distortion, but working with such an arthroscopy in nearly impossible and it needs changing additional arthroscopy lenses during the procedure. Hyper flexing the knee to the described 110˚ - 130˚ is also associated with complications, including loss of visualization, fat pad ingress, poor arthroscopic inflow, inability to sea instrumentation, and bending of rigid guide wires [<xref ref-type="bibr" rid="scirp.97778-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.97778-ref21">21</xref>].</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Comparison of the relative standard deviation of radial distortion in Knee No 1 through the AM, AL and TT portal using different angles of knee position</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Angle of knee position [˚]</th><th align="center" valign="middle" >AM portal relatively standard deviation of radial distortion [%]</th><th align="center" valign="middle" >AL portal relatively standard deviation of radial distortion [%]</th><th align="center" valign="middle" >TT portal relatively standard deviation of radial distortion [%]</th></tr></thead><tr><td align="center" valign="middle" >30</td><td align="center" valign="middle" >no visibility</td><td align="center" valign="middle" >no visibility</td><td align="center" valign="middle" >0.95</td></tr><tr><td align="center" valign="middle" >50</td><td align="center" valign="middle" >0.68</td><td align="center" valign="middle" >1.24</td><td align="center" valign="middle" >0.68</td></tr><tr><td align="center" valign="middle" >70</td><td align="center" valign="middle" >1.46</td><td align="center" valign="middle" >1.20</td><td align="center" valign="middle" >0.54</td></tr><tr><td align="center" valign="middle" >90</td><td align="center" valign="middle" >1.10</td><td align="center" valign="middle" >1.27</td><td align="center" valign="middle" >0.15</td></tr><tr><td align="center" valign="middle" >110</td><td align="center" valign="middle" >0.40</td><td align="center" valign="middle" >1.18</td><td align="center" valign="middle" >0.15</td></tr><tr><td align="center" valign="middle" >130</td><td align="center" valign="middle" >0.10</td><td align="center" valign="middle" >0.70</td><td align="center" valign="middle" >0.08</td></tr></tbody></table></table-wrap><p>AM: anteromedial, AL: anterolateral, TT: transtibial, <sup>a</sup>visualization in not possible due to impingement of the arthroscope.</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Comparison of the relative standard deviation of radial distortion in Knee No. 4. through the AM, AL and TT portal using different angles of knee position</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Angle of knee position [˚]</th><th align="center" valign="middle" >AM portal relatively standard deviation of radial distortion [%]</th><th align="center" valign="middle" >AL portal relatively standard deviation of radial distortion [%]</th><th align="center" valign="middle" >TT portal relatively standard deviation of radial distortion [%]</th></tr></thead><tr><td align="center" valign="middle" >30</td><td align="center" valign="middle" >no visibility</td><td align="center" valign="middle" >not clear</td><td align="center" valign="middle" >not clear</td></tr><tr><td align="center" valign="middle" >50</td><td align="center" valign="middle" >1.56</td><td align="center" valign="middle" >not clear</td><td align="center" valign="middle" >not clear</td></tr><tr><td align="center" valign="middle" >70</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" >not clear</td><td align="center" valign="middle" >0.21</td></tr><tr><td align="center" valign="middle" >90</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle" >0.57</td><td align="center" valign="middle" >0.36</td></tr><tr><td align="center" valign="middle" >110</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >0.48</td><td align="center" valign="middle" >0.24</td></tr><tr><td align="center" valign="middle" >130</td><td align="center" valign="middle" >0.63</td><td align="center" valign="middle" >0.80</td><td align="center" valign="middle" >0.62</td></tr></tbody></table></table-wrap><p>AM: anteromedial, AL: anterolateral, TT: transtibial, <sup>a</sup>visualization is not possible due to impingement of the arthroscope, <sup>b</sup>separating different dots is not possible.</p><p>There were some limitations of this study. First, all images are made by two observers. In comparison to other studies that were at least two observers were involved, but independently [<xref ref-type="bibr" rid="scirp.97778-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.97778-ref23">23</xref>]. In our study two participants calculated the deviation of radial distortion. Second, the Sawbones&#174; knee models have no patellar tendon. Therefore, the position of AM and AL portals is subject to certain positional errors. Lastly, only two standard portal positions were tested and compared to the TT portal. Also, the measurements were not performed in a saline solution as it was by Hoshino et al. [<xref ref-type="bibr" rid="scirp.97778-ref11">11</xref>]. Future studies are needed to measure radial distortion of the image through additional viewing portals, and in combination with immerging the models in saline solution.</p></sec><sec id="s4"><title>4. Conclusion</title><p>Magnification and shape of the image are inconsistent using different viewing portals and knee bending angles. The least distorted and the most consistent arthroscopic image of the femoral footprint can be obtained when using the TT portal and by bending the knee to 90˚ - 130˚ with a 30˚ arthroscope. Also, the best visualization is performed by drilling the tibia using a 50˚ guide pin with the extra articular starting point 0.5 cm medial to the tuberositas tibiae and 2 cm proximal to the upper rim of the pes anserinus projection. Future studies are needed to evaluate the measured angles in vivo and to calculate the postoperative performance using this method.</p></sec><sec id="s5"><title>Acknowledgements</title><p>Our gratitude to Professor Milankov M. from the Department of Surgery at the University of Novi Sad for assisting in technical details and support.</p></sec><sec id="s6"><title>Funding</title><p>There is no funding source.</p></sec><sec id="s7"><title>Ethical Approval</title><p>This article does not contain any studies with human participants or animals.</p></sec><sec id="s8"><title>Conflicts of Interest</title><p>The authors declare that they have no conflict of interest.</p></sec><sec id="s9"><title>Cite this paper</title><p>Vranješ, M., Cvejić, Z., Todorović, N., Gojković, Z. and Harhaji, V. (2020) Radial Distortion of the Arthroscopic Transtibial Portal: A 2-Dimensional in Vitro Model. Open Access Library Journal, 7: e6035. https://doi.org/10.4236/oalib.1106035</p></sec></body><back><ref-list><title>References</title><ref id="scirp.97778-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Aglietti, P., Buzzi, R., Giron, F., Simeone, A.J.V. and Zaccherotti, G. (1997) Arthro-scopic-Assisted Anterior Cruciate Ligament Reconstruction with the Central Third Patellar Tendon. A 5-8-Year Follow-Up. Knee Surgery, Sports Traumatology, Ar-throscopy, 5, 138-144. https://doi.org/10.1007/s001670050041</mixed-citation></ref><ref id="scirp.97778-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Khalfayan, E.E., Sharkey, P.F., Alexander, A.H., Bruckner, J.D. and Bynum, E.B. (1996) The Rela-tionship between Tunnel Placement and Clinical Results after Anterior Cruciate Ligament Reconstruction. The American Journal of Sports Medicine, 24, 335-341. https://doi.org/10.1177/036354659602400315</mixed-citation></ref><ref id="scirp.97778-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Sommer, C., Friederich, N.F. and Muller, W. (2000) Improperly Placed Anterior Cruciate Ligament Grafts: Correlation between Radiological Parameters and Clinical Results. Knee Surgery, Sports Trau-matology, Arthroscopy, 8, 207-213. https://doi.org/10.1007/s001670000125</mixed-citation></ref><ref id="scirp.97778-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Bottoni, C.R., Liddell, T.R., Trainor, T.J., Freccero, D.M. and Lindell, K.K. (2008) Postoperative Range of Motion Following Anterior Cruciate Ligament Reconstruction Using Autograft Hamstrings: A Prospective, Randomized Clinical Trial of Early versus Delayed Reconstructions. The American Journal of Sports Medicine, 36, 656-662. https://doi.org/10.1177/0363546507312164</mixed-citation></ref><ref id="scirp.97778-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Harner, C.D., Honkamp, N.J. and Ranawat, A.S. (2008) Anteromedial Portal Technique for Creating the Anterior Cru-ciate Ligament Femoral Tunnel. Arthroscopy, 24, 113-115. https://doi.org/10.1016/j.arthro.2007.07.019</mixed-citation></ref><ref id="scirp.97778-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Jaecker, V., Zapf, T., Naendrup, J.H., Pfeiffer, T., Kanakamedala, A.C., et al. (2017) High Non-Anatomic Tunnel Po-sition Rates in ACL Reconstruction Failure Using Both Transtibial and Anteromedial Tunnel Drilling Techniques. Archives of Orthopaedic and Trauma Surgery, 137, 1293-1299. https://doi.org/10.1007/s00402-017-2738-3</mixed-citation></ref><ref id="scirp.97778-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Vaseenon, T., Phisitkul, P., Wolf, B.R., Femino, J.E. and Amendola, A. (2011) Preventing Damage to Arthroscopic Lens during Surgery. Arthroscopy, 27, 404-408. https://doi.org/10.1016/j.arthro.2010.07.019</mixed-citation></ref><ref id="scirp.97778-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Carlsen, A. (1986) A Broken Telescope: A Complication of Arthroscopy. Arthroscopy, 2, 182-183. https://doi.org/10.1016/S0749-8063(86)80064-0</mixed-citation></ref><ref id="scirp.97778-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Hoshino, Y., Rothrauff, B., Hensler, D., Fu, F. and Musahl, V. (2016) Arthroscopic Image Distortion Part I: The Effect of Lens and Viewing Angles in a 2-Dimensional in Vitro Model. Knee Surgery, Sports Traumatology, Arthroscopy, 24, 2065-2071. https://doi.org/10.1007/s00167-014-3336-3</mixed-citation></ref><ref id="scirp.97778-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Hoshino, Y., Nagamune, K., Yagi, M., Araki, D., Nishimoto, K., et al. (2009) The Effect of Intraoperative Knee Flexion Angle on Determination of Graft Location in the Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction. Knee Surgery, Sports Traumatology, Ar-throscopy, 17, 1052-1060. https://doi.org/10.1007/s00167-009-0773-5</mixed-citation></ref><ref id="scirp.97778-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Hoshino, Y., Rothrauff, B.B., Hensler, D., Fu, F.H. and Musahl, V. (2016) Arthroscopic Image Distortion Part II: The Effect of Lens Angle and Portal Location in a 3D Knee Model. Knee Surgery, Sports Traumatology, Arthroscopy, 24, 2072-2078. https://doi.org/10.1007/s00167-014-3268-y</mixed-citation></ref><ref id="scirp.97778-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Zantop, T., Haase, A.K., Fu, F.H. and Petersen, W. (2008) Potential Risk of Cartilage Damage in Double Bundle ACL Reconstruction: Impact of Knee Flexion Angle and Portal Location on the Fem-oral PL Bundle Tunnel. Archives of Orthopaedic and Trauma Surgery, 128, 509-513. https://doi.org/10.1007/s00402-007-0480-y</mixed-citation></ref><ref id="scirp.97778-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">McMillan, S., Saini, S., Alyea, E. and Ford, E. (2017) Office-Based Needle Arthroscopy: A Standardized Diagnostic Approach to the Knee. Arthroscopy Techniques, 6, 1119-1124. https://doi.org/10.1016/j.eats.2017.03.031</mixed-citation></ref><ref id="scirp.97778-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Lubowitz, J.H. (2009) Anteromedial Portal Technique for the Anterior Cruciate Ligament Femoral Socket: Pitfalls and Solutions. Arthroscopy, 25, 95-101. https://doi.org/10.1016/j.arthro.2008.10.012</mixed-citation></ref><ref id="scirp.97778-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Bedi, A. and Altchek, D.W. (2009) The “Footprint” Anterior Cruciate Ligament Technique: An Anatomic Approach to Anterior Cruciate Ligament Reconstruction. Arthroscopy, 25, 1128-1138. https://doi.org/10.1016/j.arthro.2009.03.008</mixed-citation></ref><ref id="scirp.97778-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Cho, Y., Cho, J. and Kim, D. (2012) Normal Sagittal of the Anterior Cruciate Ligament Can Be Reproduced Using Accessory Anteromedial Portal Technique: A Magnetic Resonance Imaging Study. Archives of Orthopaedic and Trauma Surgery, 132, 1011-1019. https://doi.org/10.1007/s00402-012-1498-3</mixed-citation></ref><ref id="scirp.97778-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Guler, O., Mah?rogullar?, M., Mutlu, S., Cerc?, M.H., Seker, A., et al. (2016) Graft Position in Arthroscopic Anterior Cru-ciate Ligament Reconstruction: Anteromedial versus Transtibial Technique. Archives of Orthopaedic and Trauma Surgery, 136, 1571-1580. https://doi.org/10.1007/s00402-016-2532-7 </mixed-citation></ref><ref id="scirp.97778-ref18"><label>18</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Brown</surname><given-names> D.C. </given-names></name>,<etal>et al</etal>. (<year>1971</year>)<article-title>Close-Range Camera Calibration</article-title><source> Photogrammetric Engineering</source><volume> 37</volume>,<fpage> 855</fpage>-<lpage>866</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.97778-ref19"><label>19</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Brown</surname><given-names> D.C. </given-names></name>,<etal>et al</etal>. (<year>1966</year>)<article-title>Decentering Distortion of Lenses</article-title><source> Photogrammetric Engineering</source><volume> 32</volume>,<fpage> 444</fpage>-<lpage>462</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.97778-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Drap, P. and Lefèvre, J. (2016) An Exact Formula for Calculating In-verse Radial Lens Distortions. Sensors, 16, 807. https://doi.org/10.3390/s16060807</mixed-citation></ref><ref id="scirp.97778-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Dougherty, G. (2009) Digital Image Pro-cessing for Medical Applications. Cambridge University Press, New York. https://doi.org/10.1017/CBO9780511609657</mixed-citation></ref><ref id="scirp.97778-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Hartley, R. and Kang, S.B. (2007) Parameter-Free Radial Distortion Correction with the Center of Distortion Estimation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 29, 1309-1321. https://doi.org/10.1109/TPAMI.2007.1147</mixed-citation></ref><ref id="scirp.97778-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Asari, K.V., Kumar, S. and Radha-krishnan, D. (1999) A New Approach for Nonlinear Distortion Correction in Endo-scopic Images Based on Least Squares Estimation. IEEE Transactions on Medical Imaging, 18, 345-354. https://doi.org/10.1109/42.768843</mixed-citation></ref></ref-list></back></article>