<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AJAC</journal-id><journal-title-group><journal-title>American Journal of Analytical Chemistry</journal-title></journal-title-group><issn pub-type="epub">2156-8251</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ajac.2019.105013</article-id><article-id pub-id-type="publisher-id">AJAC-92332</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Global Optimization of Norris Derivative Filtering with Application for Near-Infrared Analysis of Serum Urea Nitrogen
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yihui</surname><given-names>Yang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tao</surname><given-names>Pan</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jing</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Optoelectronic Engineering, Jinan University, Guangzhou, China</addr-line></aff><pub-date pub-type="epub"><day>09</day><month>05</month><year>2019</year></pub-date><volume>10</volume><issue>05</issue><fpage>143</fpage><lpage>152</lpage><history><date date-type="received"><day>15,</day>	<month>April</month>	<year>2019</year></date><date date-type="rev-recd"><day>7,</day>	<month>May</month>	<year>2019</year>	</date><date date-type="accepted"><day>10,</day>	<month>May</month>	<year>2019</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Near-infrared (NIR) spectroscopy combined with chemometrics methods was applied to the rapid and reagent-free analysis of serum urea nitrogen (SUN). The mul-partitions modeling was performed to achieve parameter stability. A large-scale parameter cyclic and global optimization platform for Norris derivative filter (NDF) of three parameters (the derivative order: 
  d, the number of smoothing points: 
  s and the number of differential gaps: 
  g) was developed with PLS regression. Meantime, the parameters’ adaptive analysis of NDF algorithm was also given, and achieved a significantly better modeling effect than one without spectral pre-processing. After eliminating the interference wavebands of saturated absorption, the modeling performance was further improved. In validation, the root mean square error (SEP), correlation coefficient (R
  <sub>P</sub>) for prediction and the ratio of performance to deviation (RPD) were 1.66 mmol∙L
  <sup>-1</sup>, 0.966 and 4.7, respectively. The results showed that the high-precision analysis of SUN was feasibility based on NIR spectroscopy and Norris-PLS. The global optimization method of NDF is also expected to be applied to other analysis objects.
 
</p></abstract><kwd-group><kwd>Near-Infrared Spectral Analysis</kwd><kwd> Serum Urea Nitrogen</kwd><kwd> Norris Derivative Filter</kwd><kwd> Norris-Partial Least Squares</kwd><kwd> Global Optimization</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>As we know, near-infrared (NIR) spectroscopy primarily reflects the absorption of overtones and combinations of vibrations of X-H functional groups (such as C?H, O?H and N?H), has obvious advantages in rapid and reagent-free analyses, and has been effectively used in agriculture [<xref ref-type="bibr" rid="scirp.92332-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref4">4</xref>] , food [<xref ref-type="bibr" rid="scirp.92332-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref8">8</xref>] , environment [<xref ref-type="bibr" rid="scirp.92332-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref10">10</xref>] , biomedicine and other fields [<xref ref-type="bibr" rid="scirp.92332-ref11">11</xref>] - [<xref ref-type="bibr" rid="scirp.92332-ref16">16</xref>] . NIR spectroscopy of most sample types can usually be measured directly without physically or chemically treating. It is possible to directly measure complex liquid samples containing multiple components (e.g. blood, milk, etc.) by transmission. However, its spectrum contains both instrumental noise and interference caused by other unknown components. Thus spectral pretreatment of high signal-to-noise ratio is significantly necessary to solve this problem.</p><p>In spectral preprocessing, appropriate smoothing and derivative can effectively eliminate noises. The famous Norris derivative filter (NDF) includes two steps: the moving average smoothing and differential derivation. It uses three parameters: the derivative order (d), the number of smoothing points (s) and the number of differential gaps (g). NDF is an algorithm group with various parameters and modes, which is often used in the NIR analysis [<xref ref-type="bibr" rid="scirp.92332-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref18">18</xref>] . The appropriate Norris modes should be chosen according to the analytical objects. It is necessary to make large-scale optimization selections for Norris modes. Due to the heavy workload, such work has not been reported yet.</p><p>Serum urea nitrogen (SUN) is an important indicator for clinical evaluation of renal function and protein metabolism. It plays an important role in the diagnosis of renal diseases in acute myocardial infarction [<xref ref-type="bibr" rid="scirp.92332-ref19">19</xref>] and acute heart failure [<xref ref-type="bibr" rid="scirp.92332-ref20">20</xref>] . And it is also an adjunct predictor of acute pancreatitis [<xref ref-type="bibr" rid="scirp.92332-ref21">21</xref>] , hypertension and depression. The normal value of SUN is 2.9 to 7.5 mmol∙L<sup>−1</sup>. The conventional analytical methods for SUN include gas chromatography, ion conductivity and urease methods. These methods require chemical reagents and complex operations, which are inconvenient for rapid and daily screening of large population. Therefore, the development of simple and rapid analytical method for SUN in the routine testing is of great significance.</p><p>In fact, the serum urea nitrogen (CO(NH<sub>2</sub>)<sub>2</sub>) contains the hydrogen-containing group (-NH<sub>2</sub>), which has characteristic absorption in the NIR region. Therefore, in molecular level, the NIR spectrum has the possibility to quantitatively analyze urea nitrogen. There have been some researches and developments in this area, such as using NIR spectroscopy to analyze the urea nitrogen content in serum simulated solution or urine [<xref ref-type="bibr" rid="scirp.92332-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.92332-ref16">16</xref>] . Recently, silver mirror enhanced NIR diffuse reflectance spectroscopy has been proposed for the analysis of SUN [<xref ref-type="bibr" rid="scirp.92332-ref22">22</xref>] . However, the existing analytical accuracy did not meet the requirements of clinical application, further innovation in methods is very necessary. And it is also crucial to conduct chemometric studies for model optimization.</p><p>In this study, combined with partial least squares (PLS) regression, a large-scale parameter cyclic and global optimization platform for NDF algorithm was constructed to achieve globally optimal selection. And the NIR spectroscopic analysis of SUN was taken as an example to evaluate the performance of the proposed NDF platform.</p></sec><sec id="s2"><title>2. Methods and Materials</title><sec id="s2_1"><title>2.1. Experimental Materials, Instruments and Measurement Methods</title><p>A total of 210 serum samples were collected from a hospital, the clinical actual values of serum urea nitrogen of the samples were obtained. The SUN values ranged from 2.1 to 41.6 (mmol∙L<sup>−1</sup>), and the mean and standard deviation (SD) were 8.0 and 7.0 (mmol∙L<sup>−1</sup>), respectively. Since the serum samples were collected and used in this study, the informed consent of all individual participants was obtained. The experiment was carried out according to relevant laws and institutional guidelines and approved by local medical institutions, which obtained the informed consent of all participants.</p><p>The instrument was an XDS Rapid Content™ Liquid Grating Spectrometer (FOSS, Denmark) equipped with a 2 mm. The spectra spanned 780 to 2498 nm with a 2 nm wavelength gap, including the overall NIR region. The detectors on wavebands of 780 - 1100 and 1100 - 2498 nm were Si and PbS detectors, respectively. Every sample was measured thrice. And the average spectrum of each sample was calculated and used for modeling. The spectra were measured at 25˚C &#177; 1˚C and 46% &#177; 1% relative humidity.</p></sec><sec id="s2_2"><title>2.2. Mul-Partition Modeling</title><p>The 75 samples were randomly selected from 210 samples as independent validation set (not involved in modeling). The remaining 135 samples were used as the modeling set, which was further divided into calibration (80 samples) and prediction (55 samples) sets for 10 times to achieve the parameter stability. The root-mean-square errors (SEP) and correlation coefficients (R<sub>P</sub>) for prediction were determined for each partition. The mean values (SEP<sub>Ave</sub>, R<sub>P,Ave</sub>) and standard deviations (SEP<sub>SD</sub>, R<sub>P,SD</sub>) for all the partitions were further determined, respectively. The comprehensive indicator SEP<sup>+</sup> = SEP<sub>Ave</sub> + SEP<sub>SD</sub> was used to select the parameters with stability. The SEP<sup>+</sup> takes the modeling prediction accuracy (SEP<sub>Ave</sub>) and stability (SEP<sub>SD</sub>) both into account. The selected models were validated using the validation set. The corresponding SEP, R<sub>P</sub>, and ratio of performance to deviation (RPD) were further determined, respectively. R P D = C S D S E P , where C<sub>SD</sub> was SD of actual values for the 75 samples (Mean: 8.6 mmol∙L<sup>−1</sup>; SD: 7.8 mmol∙L<sup>−1</sup>).</p></sec><sec id="s2_3"><title>2.3. Norris Derivative Filter Algorithm</title><p>The NDF algorithm uses the symmetrical window of wavelengths to perform moving average smoothing on spectra firstly. The number of wavelengths in the smoothing-window is called the number of smoothing points (s, odd), which is set to s = 1 , 3 , ⋯ , S ; S can take the maximum odd number of the total number of wavelengths (N<sub>0</sub>) in the entire spectral waveband. Since the low correlation, it is unreasonable to use a too wide smoothing-window. In this study, the upper limit S was set as 99. In addition, when s = 1, the moving average smoothing cannot be performed for that the original spectra were not pretreated.</p><p>The absorbance of the k<sup>th</sup> wavelength was x<sub>k</sub>. And the absorbance of the smoothing-window center x<sub>k</sub> were x<sub>i</sub>, i ∈ [ k − s − 1 2 , k + s − 1 2 ] . The smoothing value of x<sub>k</sub> was as follows:</p><p>x ˜ k = ∑ i = k − s − 1 2 k + s − 1 2 x i s (1)</p><p>It’s worth noting that for the leftmost s − 1 2 and rightmost wavelengths, the symmetrically smoothing cannot be performed. Based on an idea of data continuity, for the leftmost s − 1 2 wavelengths, the smoothing values of the absorbance x<sub>k</sub> were as follows:</p><p>x ˜ k = ∑ i = 1 k + s − 1 2 x i k + s − 1 2 , k = 1 , 2 , ⋯ , s − 1 2 (2)</p><p>For the rightmost s − 1 2 wavelengths, the smoothing method was similar and omitted.</p><p>Difference derivation: The spectra pretreated by moving average smoothing were then used for derivation. The 1<sup>st</sup> derivative of absorbance was calculated using the center difference method. Since the NIR spectra are relatively flat and the spectral resolution of different objects is usually different, the original spectral data gap is not necessarily suitable for the differential gap of derivative. The Norris derivative uses variable number of wavelength gaps as the number of differential gaps (g) for the derivative, g = 1 , 2 , ⋯ , G . Large g is unreasonable due to the correlation is low. In this study, the upper limit G was set as 50.</p><p>For x<sub>k</sub>, the 1<sup>st</sup> derivative of absorbance was calculated using the following center difference:</p><p>D x k = x ˜ k + g − x ˜ k − g 2 g (3)</p><p>Similarly, for the leftmost and the rightmost g wavelengths respectively, the center difference cannot be performed. Based on the idea of data continuity, for the g leftmost wavelengths, the 1<sup>st</sup> derivative value of the absorbance was calculated by the forward difference method as follows:</p><p>D x k = x ˜ k + g − x ˜ k g , k = 1 , 2 , ⋯ , g (4)</p><p>For the rightmost g wavelengths, the calculation method for 1<sup>st</sup> derivative value of the absorbance was similar and omitted.</p><p>The 2<sup>nd</sup> derivative value can be obtained by derivation on the basis of the above 1<sup>st</sup> derivative value, and the process was not described again.</p><p>Optimization: Considering that the absolute value of the derivative of the 3<sup>rd</sup> or more is small and the spectral information is low, it is generally not recommended to use the derivative of the 3<sup>rd</sup> or more. In this study, the derivative order is set as d = 0, 1, 2. In particular, when d = 0, only the previous moving average smoothing was required.</p><p>As above, based on parameters combinations (d, s, g), d = 0, 1, 2; s = 1 , 3 , ⋯ , 99 ; g = 1 , 2 , ⋯ , 50 , a total of 5050 NDF modes were obtained. They were used to pretreat the sample spectra separately. The corrected spectra were then used to establish PLS models, named Norris-PLS models. Finally, according to the predicted effect, the optimal parameters were preferred as follows:</p><p>S E P ∗ + = min d ∈ { 0 , 1 , 2 } s ∈ { 1 , 3 , ⋯ , 99 } g ∈ { 1 , 2 , ⋯ , 50 } S E P ( d , s , g ) (5)</p><p>The s and the g are both important parameters of NDF. When d = 0, there is only one variable parameter s. The corresponding prediction error is SEP<sup>+</sup>(0, s), s = 1 , 3 , ⋯ , 99 . When d = 1, 2, there are two variable parameters (s, g). The corresponding single-parameter local optimal models were as follows:</p><p>S E P + ( d , s ) = m i n g ∈ { 1 , 2 , ⋯ , 50 } S E P + ( d , s , g ) , d = 1 , 2 ; s = 1 , 3 , ⋯ , 9 9 (6)</p><p>S E P + ( d , g ) = m i n s ∈ { 1 , 3 , ⋯ , 99 } S E P + ( d , s , g ) , d = 1 , 2 ; g = 1 , 2 , ⋯ , 5 0 (7)</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Direct PLS Model without Pretreatment</title><p>The NIR spectra of the 210 serum samples in the entire scanning region (780 - 2498 nm) are illustrated in “<xref ref-type="fig" rid="fig1">Figure 1</xref>(a)”. As comparison, the PLS model in the whole region (780 - 2498 nm) without spectral pretreatment was established. The modeling effect (SEP<sub>Ave</sub>, R<sub>P,Ave</sub>, SEP<sub>SD</sub>, R<sub>P,SD</sub>, and SEP<sup>+</sup>) are summarized in “<xref ref-type="table" rid="table1">Table 1</xref>”. The results showed that high prediction error (SEP<sup>+</sup> = 7.07 mmol∙L<sup>−1</sup>) and low correlation (R<sub>P</sub> = 0.535).</p></sec><sec id="s3_2"><title>3.2. Norris-PLS Models</title><p>All Norris-PLS models corresponding to 5050 NDF modes also were established. For different derivative order, the optimal SEP<sup>+</sup> corresponding to each single-parameter (number of smoothing points s or number of differential gaps g) are shown in “<xref ref-type="fig" rid="fig2">Figure 2</xref>”. It can be observed that the global optimal NDF mode was 2<sup>nd</sup> derivative, 33 smoothing points and 15 differential gaps (d = 2, s = 33 and g = 15). The corresponding SEP<sup>+</sup> and R<sub>P</sub> were obviously improved to 2.62 mmol∙L<sup>−1</sup> and 0.930, respectively. In particular, the prediction error (SEP<sup>+</sup>) is only 37% of the original. From “<xref ref-type="fig" rid="fig2">Figure 2</xref>”, it is observed that the prediction effects corresponding to different parameters (d, s, g) are significantly different. Thus, the ergodic choice of the parameters was significantly necessary to achieve</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Prediction effects of modelling for the analysis of SUN (mmol∙L<sup>−1</sup>)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Methods</th><th align="center" valign="middle" >Wavelengths (nm)</th><th align="center" valign="middle" >LV</th><th align="center" valign="middle" >SEP<sub>Ave</sub></th><th align="center" valign="middle" >SEP<sub>SD</sub></th><th align="center" valign="middle" >R<sub>P,Ave</sub></th><th align="center" valign="middle" >R<sub>P,SD</sub></th><th align="center" valign="middle" >SEP<sup>+</sup></th><th align="center" valign="middle" ></th></tr></thead><tr><td align="center" valign="middle" >PLS</td><td align="center" valign="middle" >780 - 2498</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" >6.14</td><td align="center" valign="middle" >0.90</td><td align="center" valign="middle" >0.527</td><td align="center" valign="middle" >0.133</td><td align="center" valign="middle"  colspan="2"  >7.05</td></tr><tr><td align="center" valign="middle" >Norris-PLS</td><td align="center" valign="middle" >780 - 2498</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >2.47</td><td align="center" valign="middle" >0.15</td><td align="center" valign="middle" >0.930</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle"  colspan="2"  >2.62</td></tr><tr><td align="center" valign="middle" ></td><td align="center" valign="middle" >780 - 1880 &amp; 2082 - 2344</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >1.71</td><td align="center" valign="middle" >0.16</td><td align="center" valign="middle" >0.966</td><td align="center" valign="middle" >0.007</td><td align="center" valign="middle"  colspan="2"  >1.87</td></tr></tbody></table></table-wrap><p>better modeling performance. The prediction effects of the global optimal Norris-PLS model are also summarized in “<xref ref-type="table" rid="table1">Table 1</xref>”. The spectra used the optimal NDF mode (d = 2, s = 33, g = 15) are shown in “<xref ref-type="fig" rid="fig1">Figure 1</xref>(b)”.</p><p>In fact, there was significant saturate absorbance around 1900nm and 2400 nm in raw spectra, see in “<xref ref-type="fig" rid="fig1">Figure 1</xref>(a)”. They introduce noise and have an impact on modeling. Therefore, the absorbance higher than 3 (corresponded 99.9% absorption rate) was further excluded, and the remaining was 780 - 1880 &amp; 2082 - 2344 nm. On the basis of the NDF spectra, the PLS model was established in the unsaturated region (780 - 1880 &amp; 2082 - 2344 nm). The modeling effect is also summarized in <xref ref-type="table" rid="table1">Table 1</xref>. The SEP<sup>+</sup> and was R<sub>P</sub> further improved to 1.87 mmol∙L<sup>−1</sup> and 0.966, respectively. Among then, the SEP<sup>+</sup> further declined 29%.</p><p>Therefore, eliminating the interference waveband with high-absorption does help to improve the modeling effect.</p></sec><sec id="s3_3"><title>3.3. Models Validation</title><p>The 75 validation samples not incorporated in modeling were used to evaluate the Norris-PLS model that were established in the unsaturated region (780 - 1880 &amp; 2082 - 2344 nm) with the optimal NDF mode. The PLS regression coefficients were determined using the spectra and actual SUN values of all modeling samples. The predicted values were then determined using the resulting regression coefficients and the spectra of the validation samples.</p><p>For the model, the relationship between the predicted and actual SUN values is shown in “<xref ref-type="fig" rid="fig3">Figure 3</xref>”. The evaluation values for validation (SEP, R<sub>P</sub>, and RPD) are 1.66 mmol∙L<sup>−1</sup>, 0.977 and 4.7, respectively. This model has achieved good prediction effect. The prediction values were close to the actual values with high precision and correlation. The results showed that the prediction effects corresponding to different parameters were significantly different. The parameters can’t be pre-set by experience. The global optimization of the parameters was significantly necessary to achieve better modeling performance.</p></sec></sec><sec id="s4"><title>4. Conclusions</title><p>NDF algorithm is a well-performed spectral preprocessing method. The appropriate Norris modes should be chosen according to the analytical objects. It is necessary to make global optimization selection for Norris modes to achieve optimal modeling performance.</p><p>Serum urea nitrogen is an important blood clinical screening index and has clinical reference value for the diagnosis and treatment of many major diseases. The use of NIR spectroscopy to establish a rapid and reagent-free detection method for serum urea nitrogen can provide new technical support for related health screening of large populations. Using the optimal Norris-PLS model for SUN, the modelling prediction error (SEP<sup>+</sup>) further decreased to 2.62 mmol∙L<sup>−1</sup> (decline rate 63%). Then, the saturated wavebands with high absorption were removed, and the SEP<sup>+</sup> then decreased to 1.87 mmol∙L<sup>−1</sup> (decline rate 29%). Therefore, the good performance of the global optimization of NFD algorithm was indicated.</p><p>This study developed a large-scale parameter cyclic and global optimization platform for NDF algorithm and successfully used to SUN analysis. Meantime, the well-posed study of parameters in Norris-PLS method was given. We believed that the above promotion has such significance and can provide valuable reference for the NIR analysis of complex objects.</p></sec><sec id="s5"><title>Acknowledgements</title><p>This work was supported by the Science and Technology Project of Guangdong Province of China (No. 2014A020213016, No. 2014A020212445) and the University-Enterprise Joint Research Project “Intelligent detection network technology joint research centre” (No. 40115031).</p></sec><sec id="s6"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s7"><title>Cite this paper</title><p>Yang, Y.H., Pan, T. and Zhang, J. (2019) Global Optimization of Norris Derivative Filtering with Application for Near-Infrared Analysis of Serum Urea Nitrogen. American Journal of Analytical Chemistry, 10, 143-152. https://doi.org/10.4236/ajac.2019.105013</p></sec></body><back><ref-list><title>References</title><ref id="scirp.92332-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Pan, T., Li, M.M. and Chen, J.M. (2014) Selection Method of Quasi-Continuous Wavelength Combination with Applications to the Near-Infrared Spectroscopic Analysis of Soil Organic Matter. Applied Spectroscopy, 68, 263-271. https://doi.org/10.1366/13-07088</mixed-citation></ref><ref id="scirp.92332-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Chen, J.Y., Zhang, H. and Matsunaga, R. (2006) Rapid Determination of the Main Organic Acid Composition of Raw Japanese Apricot Fruit Juices Using Near-Infrared Spectroscopy. Journal of Agricultural and Food Chemistry, 54, 9652-9657. https://doi.org/10.1021/jf061461s</mixed-citation></ref><ref id="scirp.92332-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Liu, Z.Y., Liu, B., Pan, T. and Yang, J.D. (2013) Determination of Amino Acid Nitrogen in Tuber Mustard Using Near-Infrared Spectroscopy with Waveband Selection Stability. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 102, 269-274. https://doi.org/10.1016/j.saa.2012.10.006</mixed-citation></ref><ref id="scirp.92332-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Guo, H.S., Chen, J.M., Pan, T., Wang, J.H. and Cao, G. (2014) Vis-NIR Wavelength Selection for Non-Destructive Discriminant Analysis of Breed Screening of Transgenic Sugarcane. Analytical Methods, 6, 8810-8816.https://doi.org/10.1039/C4AY01833H</mixed-citation></ref><ref id="scirp.92332-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Lyu, N., Chen, J.M., Pan, T., Yao, L.J., Han, Y. and Yu, J. (2016) Near-Infrared Spectroscopy Combined with Equidistant Combination Partial Least Squares Applied to Multi-Index Analysis of Corn. Infrared Physics &amp; Technology, 76, 648-654. https://doi.org/10.1016/j.infrared.2016.01.022</mixed-citation></ref><ref id="scirp.92332-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Sousa, C., Lucio, M.M.L., Neto, M.O.F.B., Marcone, G.P.S., Pereira, A.F.C., Dantas, E.O., Fragoso, W.D. and Araujo, M.C.U. (2007) A Method for Determination of COD in a Domestic Wastewater Treatment Plant by Using Near-Infrared Reflectance Spectrometry of Seston. Analytica Chimica Acta, 588, 231-236.https://doi.org/10.1016/j.aca.2007.02.022</mixed-citation></ref><ref id="scirp.92332-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Pan, T., Chen, Z.H., Chen, J.M. and Liu, Z.Y. (2012) Near-Infrared Spectroscopy with Waveband Selection Stability for the Determination of COD in Sugar Refinery Wastewater. Analytical Methods, 4, 1046-1052. https://doi.org/10.1039/c2ay05856a</mixed-citation></ref><ref id="scirp.92332-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Jiang, J.H., Berry, R.J., Siesler, H.W. and Ozaki, Y. (2002) Wavelength Interval Selection in Multicomponent Spectral Analysis by Moving Window Partial Least-Squares Regression with Applications to Mid-Infrared and Near-Infrared Spectroscopic Data. Analytical Chemistry, 74, 3555-3565. https://doi.org/10.1021/ac011177u</mixed-citation></ref><ref id="scirp.92332-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Du, Y.P., Liang, Y.Z., Jiang, J.H., Berry, R.J. and Ozaki, Y. (2004) Spectral Regions Selection to Improve Prediction Ability of PLS Models by Changeable Size Moving Window Partial Least Squares and Searching Combination Moving Window Partial Least Squares. Analytica Chimica Acta, 501, 183-191. https://doi.org/10.1016/j.aca.2003.09.041</mixed-citation></ref><ref id="scirp.92332-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Pan, T., Xie, J., Chen, J.M. and Chen, H.Z., et al. (2010) Joint Optimization of Savitzky-Golay Smoothing Modes and PLS Factors Was Applied to Near Infrared Spectral Analysis of Serum Cholesterol. 2010 4th International Conference on Bioinformatics and Biomedical Engineering, Chengdu, China, 18-20 June 2010, 1-4. https://doi.org/10.1109/ICBBE.2010.5514789</mixed-citation></ref><ref id="scirp.92332-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Pan, T., Liu, J.M., Chen, J.M., Zhang, G.P. and Zhao, Y. (2013) Rapid Determination of Preliminary Thalassaemia Screening Indicators Based on Near-Infrared Spectroscopy with Wavelength Selection Stability. Analytical Methods, 5, 4355-4362. https://doi.org/10.1039/c3ay40732b</mixed-citation></ref><ref id="scirp.92332-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Han, Y., Chen, J.M., Pan, T. and Liu, G.S. (2015) Determination of Glycated Hemoglobin Using Near-Infrared Spectroscopy Combined with Equidistant Combination Partial Least Squares. Chemometrics and Intelligent Laboratory Systems, 145, 84-92. https://doi.org/10.1016/j.chemolab.2015.04.015</mixed-citation></ref><ref id="scirp.92332-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Yao, L.J., Lv, N., Chen, J.M., Pan, T. and Yu, J. (2016) Joint Analyses Model for Total Cholesterol and Triglyceride in Human Serum with Near-Infrared Spectroscopy. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 159, 53-59. https://doi.org/10.1016/j.saa.2016.01.022</mixed-citation></ref><ref id="scirp.92332-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Yao, L.J., Xu, W.Q., Pan, T. and Chen, J.M. (2017) Moving-Window Bis-Correlation Coefficients Method for Visible and Near-Infrared Spectral Discriminant Analysis with Applications. Journal of Innovative Optical Health Sciences, 11, 195-203. https://doi.org/10.1142/S1793545818500050</mixed-citation></ref><ref id="scirp.92332-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Kang, N., Kasemsumran, S., Woo, Y., Kim, H. and Ozaki, Y. (2006) Optimization of Informative Spectral Regions for the Quantification of Cholesterol, Glucose and Urea in Control Serum Solutions Using Searching Combination Moving Window Partial Least Squares Regression Method with Near Infrared Spectroscopy. Chemometrics and Intelligent Laboratory Systems, 82, 90-96. https://doi.org/10.1016/j.chemolab.2005.08.015</mixed-citation></ref><ref id="scirp.92332-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Suzuki, I., Ogawa, M., Seion, K., Nogawa, M., Naito, H., Yamakoshi, K. and Tanaka, S. (2018) Reagentless Estimation of Urea and Creatinine Concentrations Using Near-Infrared Spectroscopy for Spot Urine Test of Urea-to-Creatinine Ratio. Advanced Biomedical Engineering, 7, 72-81.</mixed-citation></ref><ref id="scirp.92332-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Yang, F., Xie, C.W., Liu, D.S., Yu, P.Q. and Li, Z.Y. (2010) Analysis and Estimate of Corn CNCPS Component by Near Ifrared Reflectance (NIR) Spectroscoy. Spectroscopy and Spectral Analysis, 30, 348-352.</mixed-citation></ref><ref id="scirp.92332-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, Z.H., Wang, Q.H., Wang, S.C., Dai, M.Y. and Mai, M.H. (2012) The Detection of Hatching Eggs Prior to Incubation by the Near InfraredSpectrum. Spectroscopy and Spectral Analysis, 32, 962-965.</mixed-citation></ref><ref id="scirp.92332-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">D.Z. and Ge, M. (2018) The Spatial Distribution of BUN Reference Values of Chinese Healthy Adults: A Cross-Section Study. International Journal of Biometeorology, 62, 2099-2107. https://doi.org/10.1007/s00484-018-1585-4</mixed-citation></ref><ref id="scirp.92332-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Llauger, L., Jacob, J. and Miró, ò. (2018) Renal Function and Acute Heart Failure Outcome. Medicina Clinica, 151, 281-290. https://doi.org/10.1016/j.medcle.2018.08.005</mixed-citation></ref><ref id="scirp.92332-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Cozzolino, D. and Moron, A. (2006) Potential of Near-Infrared Reflectance Spectroscopy and Chemometrics to Predict Soil Organic Carbon Fractions. Soil &amp; Tillage Research, 85, 78-85. https://doi.org/10.1016/j.still.2004.12.006</mixed-citation></ref><ref id="scirp.92332-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Wang, C.C., Yu, X.M., Cai, W.S. and Shao, X.G. (2017) Determination of Serum Urea by Near-Infrared Diffuse Reflectance Spectroscopy Using Silver Mirror for Enhancing the Detectability. Chemical Journal of Chinese Universities, 38, 1947-1952.</mixed-citation></ref></ref-list></back></article>