<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SGRE</journal-id><journal-title-group><journal-title>Smart Grid and Renewable Energy</journal-title></journal-title-group><issn pub-type="epub">2151-481X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/sgre.2019.102003</article-id><article-id pub-id-type="publisher-id">SGRE-90817</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Earth&amp;Environmental Sciences</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Control and Implementation of Single-Inverter Microgrid
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mehdi</surname><given-names>Moradian</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Milad</surname><given-names>Moradian</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Roham Sanat Engineering Co., Tehran, Iran</addr-line></aff><pub-date pub-type="epub"><day>30</day><month>01</month><year>2019</year></pub-date><volume>10</volume><issue>02</issue><fpage>29</fpage><lpage>41</lpage><history><date date-type="received"><day>12,</day>	<month>June</month>	<year>2018</year></date><date date-type="rev-recd"><day>25,</day>	<month>February</month>	<year>2019</year>	</date><date date-type="accepted"><day>28,</day>	<month>February</month>	<year>2019</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this paper, simulation and implementation way for practical control of Single Inverter Microgrid (SIMG) is presented. This system is equipped by solar system, wind energy conversion system (WECS), and microturbine system. Each DG’s has controlled independently. This is a kind of decentralize control because each DG’s has difference controller. Control of Microgrid (MG) during both grid tie and islanding modes is presented. Solar system and WECS are modeled based on santerno products. This system is compared with three inverter MGs with Centralize control strategy. Controlled signals show that SIMG is more reliable and economical. THD is improved and strategy is simplified for SIMG.
 
</p></abstract><kwd-group><kwd>Single Inverter Microgrid</kwd><kwd> Solar System</kwd><kwd> Wind Energy Conversion System</kwd><kwd> Microturbine</kwd><kwd> Buck and Boost Chopper</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Renewable energy emerges as an alternative way of generating clean energy. As a result, increasing the use of “green” energy benefits the global environment, making it global concern. This topic relies on a variety of manufacturing and installation industries for its development. As a solution, continuously small and smart grid energy systems appear including renewable energy resources (RES), micro-generators, small energy storage systems, critical and noncritical loads, forming among them a special type of distributed generation system called the Microgrid.</p><p>Microgrids knowledge presents a wide range of solution for all of traditional grids problems such as: energy management, system stability, voltage quality, active and reactive power flow control, islanding detection, grid synchronization, and system recovery, all together and provides optimal use of small scale energy generation interaction, increases the penetration of RES, and operates in both grid connected or in autonomous modes. These small but smart grids present a new paradigm for low voltage distribution systems, in which a multilevel control system must be performed in order to ensure the proper operation of the MG [<xref ref-type="bibr" rid="scirp.90817-ref1">1</xref>] .</p><p>Recent advances using smart grid technology to maximize operations efficiency, monitoring and supervisory control, power management, and utility grid supplying, make this kind of system a suitable solution for decentralizing the electricity production. Thus, the study of these small grids is imperative because they are helpful to fulfill the maximization of the following issues:</p><p>・ Efficiency and demand trends involving technological changes.</p><p>・ Advanced energy storage systems.</p><p>・ Reduced system restoration time due to transition between the utility grid and the smart grid, improving network reliability.</p><p>・ Increased integration of distributed generation resources.</p><p>・ Increased security and tolerance to faults.</p><p>・ Power quality and system reliability.</p><p>・ Decentralized power management: how to generate an amount of power in a lot of places, rather than a lot of power in one place [<xref ref-type="bibr" rid="scirp.90817-ref2">2</xref>] .</p><p>The main aim of this paper is to solve problems related to the modeling, control, and power management of distributed generation systems based on the MG’s operating modes. Case study system is equipped by a solar system, WECS, and a microturbine system that jointed to system by dc link and choppers to a common link. All of DG’s connected to the grid by an inverter. Some loads are connected to MG. Control process explained in islanding and grid tie modes.</p><p>System modeling is developed based on the variables for an optimal control of active power flow. Voltage source inverters (VSI) are considered as electronic interface in the MG, and need for new analysis tools. Each DG’s and its control strategies are discussed in this article.</p></sec><sec id="s2"><title>2. Photovoltaic System Description</title><p>Basic implementation method for PV systems by an auxiliary system is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref> [<xref ref-type="bibr" rid="scirp.90817-ref3">3</xref>] .</p><p>The flexibility of the santerno components allows optimal configuration of the various plants, responding to every kind of need [<xref ref-type="bibr" rid="scirp.90817-ref3">3</xref>] . Reliability, considerable reduction of construction times, ease of maintenance, diagnostics and efficient repairs: these are the essential aspects of the modern photovoltaic plants aimed at constantly guaranteeing of maximizing of energy production. A typical implementation of a MV plant is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p><p>Options: 1) fiscal meters; 2) a70-terna compliant interface protection relay; 3) general safety device on the MV board; 4) self- powering system; 5) UPS; 6) premium remote control; 7) Rs485 optical-fiber converter for the connection to a string box; 8) optical-fiber switch LAN for the connection between multiple substations; 9) Anti-theft device; 10) fire device; 11) panic bar on inner side of doors.</p><p>Voltage and current waveform of simulated solar panel (Based on <xref ref-type="table" rid="table1">Table 1</xref> parameters-Appendix) is shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p></sec><sec id="s3"><title>3. Wind Power Energy Conversion Description</title><p>With a long track record in the industrial and photovoltaic field, santerno designs and manufactures wind turbine inverters of various sizes. All of products are designed for global use and therefore certified according to standards. A wide range of accessories are also available.</p><p>Displacement of pitch gearbox, yaw gearbox and generation inverter of WECS is shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>Technical features of WECS are: high quality design, extremely high reliability, output power factor, top efficiency, maximum operating voltage range, true sin-wave, output grid current, galvanic isolation from grid by means of integrated transformer, freely configurable power curve (32 points) related to turbine PM generator speed. PMSG parameters of WECS have mentioned in <xref ref-type="table" rid="table2">Table 2</xref> (Appendix).</p><p>Case study control cabinet is shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. Rectifier, inverter, filter and its control blocks are considered.</p><p>As it can be seen, output of WECS is shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>. Torque-speed, C<sub>p</sub>-λ curve, produced power and voltage of DC link of simulated wind power system are displayed. After changing the voltage to a same value by choppers, DC link tied to a mutual inverter for connecting the MGS to grid.</p></sec><sec id="s4"><title>4. Micriturbine System</title><p>Recently Microturbine (MT) systems have been much applicable because of their small size, relative low cost, repair and cheap maintenance and relatively simple control. Basic model of microturbine system with its output is discussed in [<xref ref-type="bibr" rid="scirp.90817-ref4">4</xref>] . Different dynamic models have been discussed for microturbines by Rowen, Hannet, Saha and Nern for combustion gas turbine [<xref ref-type="bibr" rid="scirp.90817-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.90817-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.90817-ref7">7</xref>] . In 1993 mathematical method of gas turbine by Rowen was developed [<xref ref-type="bibr" rid="scirp.90817-ref5">5</xref>] . While in 1993, Prime Mover Working Group by considering the control of speed, acceleration, fuel and</p><p>temperature made this model wider [<xref ref-type="bibr" rid="scirp.90817-ref6">6</xref>] . MT in this article is a small combustion turbine with an installed capacity 25 to 500 KW and a high rotation speed (between 50,000 to 120,000 rpm). This model includes the speed governor, acceleration control block, fuel system control and temperature control. Single-shaft turbine model is considered. Power producer with a Permanent Magnet Synchronous Generator (PMSG) has two poles and smooth poles rotor. Because of high speed</p><p>shaft, generators of an AC voltage source will be a high frequency (frequency angular higher than 100,000 rad/sec) [<xref ref-type="bibr" rid="scirp.90817-ref7">7</xref>] . Since turbines moves at high speed, so AC generator is a high-frequency generator which cannot be directly coupled the AC grid [<xref ref-type="bibr" rid="scirp.90817-ref8">8</xref>] . One way to model a system of distributed generation MT, based on all classification system are three following separate parts [<xref ref-type="bibr" rid="scirp.90817-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.90817-ref10">10</xref>] :</p><p>Module 1: mechanical system of turbine and fuel.</p><p>Module 2: PMSG and AC/DC rectifier and energy storage devices.</p><p>Module 3: AC/DC voltage source inverter, PWM controller.</p><p>Mechanical Model and MT Control Functions:</p><p>Analysed MT is based on Rowen and Hannet model and dynamic equations of MTS in [<xref ref-type="bibr" rid="scirp.90817-ref5">5</xref>] are investigated.</p><p>A typical model of MT system and its electrical connection process is shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>.</p><p>According to the principle of energy conversion and ignore the inverter losses, total of instantaneous powers in output of AC terminal must be equal to the instant powers in dc terminal like.</p><p>V d c I d c = v a i a + v b i b + v c i c (5)</p><p>Which I D C and V D C are dc link voltage and current.</p></sec><sec id="s5"><title>5. System Simulation</title><p>In <xref ref-type="fig" rid="fig8">Figure 8</xref> SIMG is evaluated. Benefits of SIMG compare with three-IMG [<xref ref-type="bibr" rid="scirp.90817-ref4">4</xref>] are: low implementation cost (using one inverter is more inexpensive), simple control (control of single grid-side inverter is simpler rather than three inverters), and maintenance. It’s considerable that in DC-side all DG’s should have same voltages by choppers (buck and boost). Sensitive loads are parallel in inverter output and joint to the non-sensitive load by a circuit breaker considered in point of common coupling (PCC) and then all of the system is connected to the main grid. Parameters amount are listed in Appendix.</p></sec><sec id="s6"><title>6. Buck and Boost Design for SIMG</title><p>DG’s output DC voltages level are different, hereby choppers should design for assimilated DC voltage surfaces in common bus. By considering the modulation factor (0.8), DC voltage should regulate on 275 volt [<xref ref-type="bibr" rid="scirp.90817-ref11">11</xref>]. By this means, boost chopper for solar system and WECS also buck chopper for microturbine designed.</p><p>Design of boost chopper for solar system [<xref ref-type="bibr" rid="scirp.90817-ref11">11</xref>] with consideration of 20 KHz switching frequency, 0.1 ampere current variation and 0.5 volt for voltage variation (input voltage is 35 volt):</p><p>L = V s ( V a − V s ) f V a Δ I = 35 ( 275 − 35 ) 20 &#215; 10 3 &#215; 275 &#215; 0.1 = 15   mH (1)</p><p>I a = P V a = 103 275 = 0.374 ( A ) (2)</p><p>C = I a ( V a − V s ) f V a Δ V c = 0.374 ( 275 − 35 ) 2 &#215; 10 4 &#215; 275 &#215; 0.5 = 32   μ F (3)</p><p>Boost chopper design for wind power system by considering Equations (1)-(3) is as below (input voltage is 242 volt):</p><p>L = V s ( V a − V s ) f V a Δ I = 242 ( 275 − 242 ) 20 &#215; 10 3 &#215; 275 &#215; 0.1 = 14.5   mH (4)</p><p>I a = P V a = 7100 275 = 25.81 ( A ) (5)</p><p>C = I a ( V a − V s ) f V a Δ V c = 25.81 ( 275 − 242 ) 2 &#215; 10 4 &#215; 275 &#215; 0.5 = 309   μ F (6)</p><p>Buck chopper design for microturbine system by considering 850 volt for input voltage, 20 kHz switching frequency, 0.5 (V) voltage variation, and 0.5 (A) ampere variation:</p><p>L = V a ( V s − V a ) f V s Δ I = 275 ( 850 − 275 ) 20 &#215; 10 3 &#215; 850 &#215; 0.5 = 18.6   mH (7)</p><p>C = Δ I 8 f Δ V c = 0.5 8 &#215; 2 &#215; 10 4 &#215; 0.5 = 6.25   μ F (8)</p><p>In 0.25 sec MG cuts by CB on PCC because of fault occur in grid, but in 0.42 sec reclosing process befall on PCC after fault abating. MG synchronization process with the grid is accomplished by inverter controller. Transferred power between MG and grid 1 Kw is considered (<xref ref-type="fig" rid="fig9">Figure 9</xref>).</p><p>In <xref ref-type="fig" rid="fig1">Figure 1</xref>0, adaption of voltages of MG and grid for one phase is showed. This operation is feasible by grid side applied controller and existent of Phase Loucked Loop (PLL) on it.</p><p>Rotor Angle variations of microturbine and wind power generation are shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>1 and <xref ref-type="fig" rid="fig1">Figure 1</xref>2 respectively. Microturbine speed variation also illustrated in <xref ref-type="fig" rid="fig1">Figure 1</xref>3.</p><p>THD of SIMG in grid tie and islanding modes are shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>4 and <xref ref-type="fig" rid="fig1">Figure 1</xref>5. Achieved values from simulation are in standard range. By a simple comparison between single inverter and three inverters MG concluded that THD of SIMG is less than THD of three-IMG. This is a benefit of SIMG than three-IMG.</p></sec><sec id="s7"><title>7. Conclusion</title><p>In this paper, simulation and analysis of a typical MG system has been investigated. For this system, decentralize control strategy with one inverter in grid side discussed and simulated. Practical implementation method for the case study system by santerno production has been reviewed. Sensitive loads are for SIMG and non-sensitive loads have been considered for the grid. In disconnecting time of MG from grid by PCC (exerted fault detector), SIMG operated in autonomous mode. Each DG’s produced power applied to sensitive loads. After fault clearance, grid and MG reconnect again and micro smart grid continues to operation. Buck and boost converters are designed to have same voltages at inverters input. In DC link for each DG, battery bank applied for storing the excess energy of DG’s. Reliability of grid has increased by storage devices.</p></sec><sec id="s8"><title>Conflicts of Interest</title><p>The authors declare no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s9"><title>Cite this paper</title><p>Moradian, M. and Moradian, M. (2019) Control and Implementation of Single-Inverter Microgrid. Smart Grid and Renewable Energy, 10, 29-41. https://doi.org/10.4236/sgre.2019.102003</p></sec><sec id="s10"><title>Appendix</title><p>Carrier frequency in VMPPT PWM generator, 3000 Hz and in grid-side controller, 5000 Hz, boost converter parameters: L = 0.0034   H , C = 0.00561   F . PI coefficients in grid-side controller: K p V d c = 0.05 , K i V d c = 3 , K p I d = 2.5 , K i I d = 700 , K p I q = 2.5 , K i I q = 700 .</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Values and coefficients used in PV cell</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Current Temp. Coefficient</th><th align="center" valign="middle" >α = 0.002086</th><th align="center" valign="middle" >[A/˚C]</th></tr></thead><tr><td align="center" valign="middle" >Voltage Temp. Coefficient</td><td align="center" valign="middle" >β = 0.0779</td><td align="center" valign="middle" >[V/˚C]</td></tr><tr><td align="center" valign="middle" >Reverse Saturation Current</td><td align="center" valign="middle" >I 0 = 0.5 &#215; 10 − 4</td><td align="center" valign="middle" >[A]</td></tr><tr><td align="center" valign="middle" >Short Circuit Cell Current</td><td align="center" valign="middle" >I p h = I S C = 0.5 &#215; 10 − 4</td><td align="center" valign="middle" >[A]</td></tr><tr><td align="center" valign="middle" >Cell Resistance</td><td align="center" valign="middle" >R S = 0.0277</td><td align="center" valign="middle" >[Ω]</td></tr><tr><td align="center" valign="middle" >Cell Material Coefficient</td><td align="center" valign="middle" >λ = 0.049</td><td align="center" valign="middle" >[1/V]</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Synchronous generator parameters amounts</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Unit</th><th align="center" valign="middle" >Amount</th><th align="center" valign="middle"  colspan="2"  >Parameters</th></tr></thead><tr><td align="center" valign="middle" >Ω</td><td align="center" valign="middle" >0.0485</td><td align="center" valign="middle"  colspan="2"  >Stator phase resistance R s</td></tr><tr><td align="center" valign="middle" >mH</td><td align="center" valign="middle" >0.395</td><td align="center" valign="middle"  colspan="2"  >Stator inductances ( L d , L q )</td></tr><tr><td align="center" valign="middle" >Wb</td><td align="center" valign="middle" >0.1194</td><td align="center" valign="middle" >Inductive flow by permanent magnet</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >kg.m<sup>2</sup></td><td align="center" valign="middle" >0.0027</td><td align="center" valign="middle"  colspan="2"  >Moment of inertia(J)</td></tr><tr><td align="center" valign="middle" >kw</td><td align="center" valign="middle" >14</td><td align="center" valign="middle"  colspan="2"  >Nominal power</td></tr><tr><td align="center" valign="middle" >-</td><td align="center" valign="middle" >4</td><td align="center" valign="middle"  colspan="2"  >Pairs of poles (P)</td></tr></tbody></table></table-wrap></sec></body><back><ref-list><title>References</title><ref id="scirp.90817-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">(2006) European Smart Grids Technology Platform. Printed on White Chlorine, ISBN 92-79-01414-5.</mixed-citation></ref><ref id="scirp.90817-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Quintero, J.C.V. (2009) Decentralized Control Techniques Applied to Electric Power Distributed Generation in Microgrid. Doctorate Thesis, Universitat Plitecnica De Catalunya.</mixed-citation></ref><ref id="scirp.90817-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">(2012) Solar and Wind Energy Handbook. Santerno-Carraro Group, Italy.</mixed-citation></ref><ref id="scirp.90817-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Moradian, M., Tabatabaei, F. and Moradian, S. (2013) Modeling, Control &amp; Fault Management of Microgrids. Smart Grid and Renewable Energy, 4, 99-112.  
https://doi.org/10.4236/sgre.2013.41013</mixed-citation></ref><ref id="scirp.90817-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Rowen, W.I. (1983) Simplified Mathematical Representations of Heavy Duty Gas Turbines. Journal of Engineering for Power, 105, 865-869.  
https://doi.org/10.1115/1.3227494</mixed-citation></ref><ref id="scirp.90817-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Hannet, L.N. and Khan, A. (1993) Combustion Turbine Dynamic Model Validation from Tests. IEEE Transactions on Power Systems, 8, No. 1.</mixed-citation></ref><ref id="scirp.90817-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Saha, A.K., Chowdhury, S., Chowdhury, S.P. and Crossley, P.A. (2009) Modeling and Performance Analysis of a Microturbine as a Distributed Energy Resource. IEEE Transactions on Energy Conversion, 24, No. 2.</mixed-citation></ref><ref id="scirp.90817-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Working Group on Prime Mover and Energy Supply Models for System Dynamic Performance Studies. (1994) Dynamic Models for Combined Cycle Plants in Power System Studies. IEEE Transactions on Power Systems, 9, 1698-1708.  
https://doi.org/10.1109/59.336085</mixed-citation></ref><ref id="scirp.90817-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Zamora, I., San Martin, J., Mazon, A., San Martin, J. and Aperribay, V. (2005) Emergent Technologies in Electrical Micro-generation. International Journal of Emerging Electric Power Systems, 3, No. 2.</mixed-citation></ref><ref id="scirp.90817-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Ong, C.-M. (1998) Dynamic Simulation of Electric Machinery Using Matlab/Simulink. Prentice Hall, Upper Saddle River.</mixed-citation></ref></ref-list></back></article>