<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJCE</journal-id><journal-title-group><journal-title>Open Journal of Civil Engineering</journal-title></journal-title-group><issn pub-type="epub">2164-3164</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojce.2018.82017</article-id><article-id pub-id-type="publisher-id">OJCE-85664</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  The Reduction in the Swelling Potential of the Foundation Ground of Togbl&#233;cop&#233; in Togo by the Stabilization with Binders and Sands
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kossi</surname><given-names>Bolanigni Amey</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Komi</surname><given-names>Mawutodzi Sounsah</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Komla</surname><given-names>A. S. Amoussou</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Koumah</surname><given-names>Neglo</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Ecole NationaleSupérieure des Ingénieurs(ENSI) de l’Universitéde Lomé (UL), Lomé, Togo</addr-line></aff><aff id="aff2"><addr-line>Equipe de Recherche et Devéloppement de FORMATEC, Lomé, Togo</addr-line></aff><pub-date pub-type="epub"><day>09</day><month>05</month><year>2018</year></pub-date><volume>08</volume><issue>02</issue><fpage>221</fpage><lpage>233</lpage><history><date date-type="received"><day>19,</day>	<month>April</month>	<year>2018</year></date><date date-type="rev-recd"><day>26,</day>	<month>June</month>	<year>2018</year>	</date><date date-type="accepted"><day>29,</day>	<month>June</month>	<year>2018</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The present study aims at helping to search for preventive solutions to pathologies of constructions in Togbl&#233;cop&#233; in Togo, by the reduction in the withdrawal and swelling of foundation grounds through their stabilization. Togbl&#233;cop&#233;’s clay taken from 1 m, 2 m and 3 m deep, and mixed with four binding materials (cement, sea sand, silty sand and lime). Tests of identification and free swelling with odometer are carried out on pure and stabilized materials. What emerges from these tests is that the limits of liquidity and plasticity are rising along with the rate of stabilizers while the index of plasticity is falling. Cement and lime cause a reduction in the index value of plasticity by almost 50%. The more the sand’s grain size, the more the reduction in the plasticity index. The swelling potential is reduced by 60% for cement and lime, 30% for sea sand and 20% for silty sand. The present study is a contribution to the reduction in deflations from 20% to 60% of some parts of constructions in order to limit cracks.
 
</p></abstract><kwd-group><kwd>Swelling Ground</kwd><kwd> Togo</kwd><kwd> Stabilization</kwd><kwd> Binder</kwd><kwd> Sands</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Civil engineering works aim at soils called foundation soil that is mostly clayey soils. Some clays present swelling or retracting features. Construction on such a clayey soil requires a thorough campaign of research, identification and characterization of its swelling potential. Swelling soils are very fine soils whose components are made up of layers. The swelling feature is a very complex issue, since it is the outcome of several associated phenomena that cannot be separated in terms of experiment for identification of each mechanism effect [<xref ref-type="bibr" rid="scirp.85664-ref1">1</xref>] . In dry season, swelling soils lose their saturation and the quantity of water falls down. They undergo a relatively significant reduction in volume; conversely, when they become hydrated again, the water goes through cracks and tends to capture its initial volume. Such swelling of clays depends on the state of soil capacity and on hydric conditions. The presence of swelling soils poses then a great deal of problems for designers of works [<xref ref-type="bibr" rid="scirp.85664-ref2">2</xref>] . A large number of works, constructed on marneous formations, show very often signs of degradations. These latter, characterized by cracks at the superstructure, are due to the phenomenon of withdrawal which has not been considered during their implementation and which are getting worse in the dry season. Moreover, the resulted deformations are not uniform following all directions because of the anisotropic structure of the material and depend mainly on the state of applied constraint.</p><p>Therefore, the treatment of soils is often used to upgrade their resistance in order to reduce or to increase their permeability and also to lower their compressibility [<xref ref-type="bibr" rid="scirp.85664-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.85664-ref3">3</xref>] . It is also used to reduce the soil sensitiveness to variations of the water content as is the case with expansive soils [<xref ref-type="bibr" rid="scirp.85664-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.85664-ref5">5</xref>] .</p><p>In Togo, or more exactly in Togbl&#233;cop&#233;, living quarters and other constructions go through sweeping degradations (<xref ref-type="fig" rid="fig1">Figure 1</xref>). We have been experiencing for many decades an instability characterized by a state of construction with widespread subsidence and cracking in different parts of constructions. The causes of such degradations can be searched in the instability of soil that is swelling and then subject to bad weather. This work aims to help search for preventive solution to deformations of constructions in Togbl&#233;cop&#233; in Togo through the study of swelling soils in the region. Additional lime, cement, sea sand and silty sand are used to help reduce instability of the soil by reduction in its withdrawal and swelling.</p></sec><sec id="s2"><title>2. Materials and Methods</title><sec id="s2_1"><title>2.1. Materials</title><p>- The clay samples are taken from Togbl&#233;cop&#233;, a suburb located in northern area of Lom&#233;, the capital town of Togo, about 20 km far from the downtown (<xref ref-type="fig" rid="fig2">Figure 2</xref>). The Togbl&#233;cop&#233;’s soil is a depression of the Zio River, made up of a metamorphic complex that is rich in basic minerals. This complex contains metamorphic rocks that are rich in amphibole and are derivatives of gneiss.</p><p>The coastal basin (Maastrichtian to Holocene) stretches up to Ts&#233;vi&#233; and Tabligbo and consequently covers all over this suburb. This basin is composed of sand, clay, limestone and phosphate [<xref ref-type="bibr" rid="scirp.85664-ref6">6</xref>] .</p><p>- The CPJ 35 cement manufactured by CIMTOGO and delivered in bags of 50 kg and the lime of the brand CALVIVA, delivered in bags of 25 kg are taken as samples in a commercial store of Lom&#233; in Togo.</p><p>- Silty sand and siliceous sand (sea sand) for stabilization, are taken respectively at Dalav&#233;, 35 km in northern area of Lom&#233; on Togo’s littoral in Lom&#233; (<xref ref-type="fig" rid="fig2">Figure 2</xref>)</p><p>- For different tests the following material is used: manual shaker; mechanical diving shaker with a speed equal to 10,000 tr/mn of the brand MATEST with a vessel; torpedo densimeter with range 0.995 to 1.035; tubes of brand CHEKAMAT and capacity of 2500 ml; consolidation device; oedometric cell of brand S272-01, serial number S272-01/AC/0007; piston of oedometric system; comparator at 1/100 mm; Casagrand device with cup of the brand LABOTEST and serial number Z10248; groover; dryer of the brand Air-Expert with maximal temperature 160˚C; a pycnometer of minimal volume of 500 cm<sup>3</sup> with roded top; a precision scale of the brand METTLER TOLEDO with a maximal capacity of 5 g and a precision of 0.1 g; a sieve system AFNOR.</p><p>The tests are carried out in the laboratory Lab-TP (Laboratory of Public Works) of Lom&#233; in Togo.</p></sec><sec id="s2_2"><title>2.2. Methods</title><p>Samples of reorganized or intact clayed soil are taken from 1 m, 2 m, and 3 m deep well on the soil of Togbl&#233;cop&#233;.</p><p>The stabilization of the clay from different depths is performed with cement, lime, sea sand and silty sand by proportions of 0% to 10% and at paces of 2% of the material mass.</p><p>Physical tests (density, limits of liquidity WL and plasticity WP, equivalent of sand ES and granulometries by sieving and sedimentation) are then carried out on such different materials as clay, sands and on mixtures according to standards [<xref ref-type="bibr" rid="scirp.85664-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.85664-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.85664-ref9">9</xref>] .</p><p>The free swelling is measured with oedometer on samples subject to the only weight of 1080.22 g of piston (<xref ref-type="fig" rid="fig3">Figure 3</xref>). The preparation procedure of samples is the following (<xref ref-type="fig" rid="fig4">Figure 4</xref>) [<xref ref-type="bibr" rid="scirp.85664-ref10">10</xref>] :</p><p>- Saturation of porous stones for at least 1 hour in a water pit;</p><p>- Laying of a porous stone at the base with filter paper;</p><p>- Laying of sample of soil cut up in the ring on the basic porous stone;</p><p>- Laying of a filter paper on the surface of the sample;</p><p>- Laying of the second porous stone and blocking of the whole;</p><p>- Positioning of the cell on its plate;</p><p>- Filling of the tank with distilled water for the saturation.</p><p>The variation of the height of the sample is measured according to the duration of application of the charge (12, 24, 48, 60, 120, 240, 480, 900, 1800, 3600,</p><p>7200, 14,400, 21,600, 28,800 in s) until it stabilizes. The sample is considered stable when the difference of reading between two successive times does not exceed 0.001 mm.</p><p>The reduction in final swelling Rg(%) is given by:</p><p>R g = Δ G G 0 = G 0 − G a G 0 (1)</p><p>With Rg the relative reduction in final swelling; G<sub>o</sub> the reduction in the swelling of pure clay; G<sub>a</sub> the reduction in the swelling of stabilized clay.</p></sec></sec><sec id="s3"><title>3. Results</title><sec id="s3_1"><title>3.1. Results of Characteristics of Clay and Sand Materials</title><p>The results of physical tests on the sand and clay materials are given in <xref ref-type="table" rid="table1">Table 1</xref> and <xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="fig" rid="fig6">Figure 6</xref>.</p><p><xref ref-type="table" rid="table1">Table 1</xref> and <xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="fig" rid="fig6">Figure 6</xref> show that:</p><p>- Dalav&#233;’s silty sand has an extended granulometry with a big proportion of sieved sands 0.08 mm of 20.60% with a module of fineness of 1.39 and an equivalent sand of 55. It falls then under the category of very fine sands [<xref ref-type="bibr" rid="scirp.85664-ref11">11</xref>] ;</p><p>- the sea sand doesn’t contain components that are below 0.160 mm; It has a module of fineness of 2.52 and an equivalent sand of 97.5. This sand is then of medium-sized granulometry [<xref ref-type="bibr" rid="scirp.85664-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.85664-ref13">13</xref>] ;</p><p>- the sieved sample sands of 0.08 mm taken at 1 m, 2 m, and 3 m, are respectively of 75.53%, 82.64% and 76.71%. These values are much higher than 50%; the clayed materials from Togbl&#233;cop&#233; contain then a large proportion of fine grains. Besides, absolute densities of 1 m, 2 m, and 3 m deep can be observed with respectively 2.50, 2.53, 2.54 and indexes of plasticity (Ip) of 25.24,</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Results of tests of density, module of fineness and equivalent of sand</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Materials</th><th align="center" valign="middle"  rowspan="2"  >Module of fineness</th><th align="center" valign="middle"  colspan="2"  >Density</th><th align="center" valign="middle"  rowspan="2"  >Equivalent de sand (ES in %)</th></tr></thead><tr><td align="center" valign="middle" >Apparent</td><td align="center" valign="middle" >Absolute</td></tr><tr><td align="center" valign="middle" >Silty sand</td><td align="center" valign="middle" >1.39</td><td align="center" valign="middle" >1.59</td><td align="center" valign="middle" >2.61</td><td align="center" valign="middle" >55</td></tr><tr><td align="center" valign="middle" >Sea sand</td><td align="center" valign="middle" >2.52</td><td align="center" valign="middle" >1.54</td><td align="center" valign="middle" >2.65</td><td align="center" valign="middle" >95.7</td></tr></tbody></table></table-wrap><p>34.09 and 41.73. The samples taken at 1 m and 2 m deep can then be considered as plastic whereas those taken at 3 m deep are very plastic. The soils of Togbl&#233;cop&#233; are therefore more and more plastic and dense in depth than on the surface. This Togbl&#233;cop&#233;’s soil is an instable land composed of swelling clay.</p></sec><sec id="s3_2"><title>3.2. Results of Characteristics of Composite Materials</title><p>The results of the average of the limit of liquidity and densities of different composite samples (clays, stabilizers) of different depths are shown in <xref ref-type="fig" rid="fig7">Figure 7</xref> and <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p><p>By examining <xref ref-type="fig" rid="fig7">Figure 7</xref> and <xref ref-type="fig" rid="fig8">Figure 8</xref> the following can be noticed:</p><p>- a rise in limits of liquidity and plasticity as the proportion stabilizer increases (<xref ref-type="fig" rid="fig7">Figure 7</xref>(a) and <xref ref-type="fig" rid="fig7">Figure 7</xref>(b));</p><p>- a reduction in the index value of plasticity while the percentage of stabilizer grows (<xref ref-type="fig" rid="fig7">Figure 7</xref>(c)); its reduction accelerates depending on whether the sand is thicker (<xref ref-type="fig" rid="fig7">Figure 7</xref>(c));</p><p>- the stabilization with hydraulic binders (lime and cement), presents densities that grow with their dosages; however, densities decrease with the rise in the proportion of sands (<xref ref-type="fig" rid="fig8">Figure 8</xref>);</p><p>- cement makes clay denser than lime; the density is lower in the case of stabilization with the sea sand than that of silty sand (<xref ref-type="fig" rid="fig8">Figure 8</xref>).</p></sec><sec id="s3_3"><title>3.3. Results of Mechanical Tests: The Free Swelling</title><p><xref ref-type="fig" rid="fig9">Figure 9</xref> to <xref ref-type="fig" rid="fig1">Figure 1</xref>3 show the averages of results of different depths, reductions in swellings of different stabilizers.</p><p><xref ref-type="fig" rid="fig9">Figure 9</xref> to <xref ref-type="fig" rid="fig1">Figure 1</xref>3 show that:</p><p>- in average 62% of the reduction in the potential of swelling occurs after 30 minutes for the hydraulic binders whereas it is 32% for sands. After 2 hours, 97% of the reduction in swelling occurs for the binders and 89% for the sands. After 8 hours, 100% of the potential of swelling occurs. The equations of levelling of results of proportion of stabilizer of 10%, providing the highest reduction, are shown in (<xref ref-type="fig" rid="fig1">Figure 1</xref>1):</p><p>R g c i m t = 8.717 ln ( t ) − 14.22 and R 2 = 0.921     if   t &lt; 4986 (2a)</p><p>R g c i m t = 60     if   t &gt; 4986 (2b)</p><p>R g c h t = 9.832 ln ( t ) − 23.79 and R 2 = 0.935     if   t &lt; 5025 (2c)</p><p>R g c h t = 60     if   t &gt; 5025 (2d)</p><p>R g s m t = 4.435 ln ( t ) − 14.41 and R 2 = 0.975     if   t &lt; 19200 (2e)</p><p>R g s m t = 29.33     if   t &gt; 19200 (2f)</p><p>R g s s t = 2.877 ln ( t ) − 6.977 and R 2 = 0.958     if   t &lt; 11800 (2g)</p><p>R g s s t = 20     if   t &lt; 11800 (2h)</p><p>R<sub>gcimt</sub>, R<sub>gcht</sub>, R<sub>gsmt</sub> and R<sub>gsst</sub> are respectively reduction in swelling for such additional components as cement, lime, sea sand and silty sand with t the time in s.</p><p>- for 10% of stabilizers the four additional components largely reduced the potential of swelling up to 60% for cement and lime, 30% for sea sand and 20% for silty sand (<xref ref-type="fig" rid="fig1">Figure 1</xref>1);</p><p>- The reduction in swelling goes up with the rise in the proportion of stabilizer (<xref ref-type="fig" rid="fig1">Figure 1</xref>2); the equations of levelling from these results are the following:</p><p>R g c i m T = − 0.883 T 2 + 15.09 T − 2.881 and R 2 = 0.952 (3a)</p><p>R g c h T = − 0.837 T 2 + 14.69 T − 3.297 and R 2 = 0.949 (3b)</p><p>R g s m T = − 0.125 T 2 + 4.197 T + 0.428 and R 2 = 0.988 (3c)</p><p>R g s s T = − 0.180 T 2 + 3.829 T + 0.011 and R 2 = 0.983 (cd)</p><p>R<sub>gcimT</sub>, R<sub>gchT</sub>, R<sub>gsmT</sub> and R<sub>gssT</sub> are respectively reduction in swelling for such additional components as cement, lime, sea sand and silty sand with T the proportion of stabilizer in %.</p><p>- for 4% of the proportion of lime and cement, the reduction in swelling is very pronounced; from 8% of all the stabilizers, the reduction in the potential of swelling stabilizes (<xref ref-type="fig" rid="fig1">Figure 1</xref>2);</p><p>- the swelling is more reduced with the hydraulic binders than that of sand; it is also more pronounced for the stabilizer sea sand than that of silty sand (Figures 10-12);</p><p>- the potential of reduction in swelling increases with the limits of liquidity and plasticity, it also rises with the index of plasticity (<xref ref-type="fig" rid="fig1">Figure 1</xref>3); thus, the more plastic the material the more the reduction in swelling is reduced.</p></sec></sec><sec id="s4"><title>4. Discussion</title><p>A reduction in the value of plasticity index when the percentage of stabilizer increases shows that these stabilizers influence the behavior of the clay; which is conform to the works of Djedid who showed that the limits of liquidity and plasticity are key parameters in the swelling behavior of clays [<xref ref-type="bibr" rid="scirp.85664-ref14">14</xref>] . On the other hand, the reduction in the plasticity index can be explained by:</p><p>- the rise in the quantity of pulverilent materials contained in the clayed material that has a plastifying power;</p><p>- the formation of a shell wrapping the fine grains of clay material by the minerals (CaO; SiO<sub>2</sub>; Al<sub>2</sub>O<sub>3</sub>) in cement and lime.</p><p>The growth of densities of samples from the stabilization at cement and lime according to their mixture proportion (2.498 to 2.578) may be explained by the fact that these two binders make clay more consistent. However, the reduction in the density of samples from the stabilization at sand according to the rise in their proportion and in that the granulometry is high may be justified by the fact that the additional sand makes higher the volume of the mixture whereas the mass goes down.</p><p>The rise in the limits of liquidity and plasticity, as the proportion of stabilizer increases, is in line with the results of Cabane [<xref ref-type="bibr" rid="scirp.85664-ref5">5</xref>] , which is partly opposite to the works of Hachichi [<xref ref-type="bibr" rid="scirp.85664-ref3">3</xref>] who had observed a reduction in the limit of liquidity and a rise in the plasticity by using sand, cement and lime as stabilizer saline solutions.</p><p>The reduction in swelling by cement and lime (60%) can be explained the fact that:</p><p>- when quick lime and a humid clayed soil are mixed, the quick lime hydrates rapidly by fixing a quantity of water; the divalent cations Ca<sup>2+</sup> are then able to displace the monovalent cations on the surface of clays [<xref ref-type="bibr" rid="scirp.85664-ref2">2</xref>] ;</p><p>- on the whole, cement is viewed as a granulometric corrector improving the characteristics of soil. The stabilization of the clay soil with cement forms rapidly calcic hydrates. Thus, the main mineral of cement (CaO; SiO<sub>2</sub>; Al<sub>2</sub>O<sub>3</sub>) builds a shell around the clay as is the case with concretes [<xref ref-type="bibr" rid="scirp.85664-ref5">5</xref>] .</p><p>The reduction in the swelling of clay by adding sand is more important when the components of the addition are bigger, showing the effect of the granularity of sand on the swelling (sea sand: 30% and silty sand 20%). This reduction can be interpreted by the fact that the content in clay of the mixtures decreases by addition of sand which is an inert and pulverulent materal. In fact the voids created by the grains of sand in the clay are filled by a large part the swelling [<xref ref-type="bibr" rid="scirp.85664-ref15">15</xref>] . The works of Hachichi [<xref ref-type="bibr" rid="scirp.85664-ref3">3</xref>] also revealed a significant reduction in swelling up to 80% with 40% for the sea sand.</p><p>The significant reduction in the Togbl&#233;cop&#233;’s clay by different techniques of stabilization helps contribute to the preventions of works’ pathologies, since this swelling soil causes a degree of growing saturation by capillarity under the buildings whereas the direct periphery remains subject to seasoning climate variations. This phenomenon causes differential movements of parts of the buildings leading to their excessive distortions. Thus, the reduction in the potential of swelling leads to the reduction in differential movements of some parts of the buildings. This results in the reduction in the excessive distortions in these parts.</p></sec><sec id="s5"><title>5. Conclusion</title><p>The study showed that it is possible, considering cement, lime and sands as stabilizers, to reduce the swellingpotential of Togblecop&#233;swellingsoils in Togo. The buildings undergoing excessive deformations due to swelling of the foundation soil of the zone, this reduction of swelling will thus allow the attenuation of the differential movements of the parts of the buildings thus reducing the appearance of the cracks. For the rest of this work, a study must be made through tests of determination of the mechanical strengths in order to appreciate the mechanical behavior of this swelling sol with respect to the stabilization.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This work could not have been carried out without the logistic and financial support from FORMATEC we express our sincere gratitude to.</p></sec><sec id="s7"><title>Cite this paper</title><p>Amey, K.B., Sounsah, K.M., Amoussou, K.A.S. and Neglo, K. (2018) The Reduction in the Swelling Potential of the Foundation Ground of Togbl&#233;cop&#233; in Togo by the Stabilization with Binders and Sands. Open Journal of Civil Engineering, 8, 221-233. https://doi.org/10.4236/ojce.2018.82017</p></sec></body><back><ref-list><title>References</title><ref id="scirp.85664-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Medjnoun, A. (2014) Analyse, caractérisation, prévision et modélisation du comportement des argiles gonflants. Thèse de doctorat, Université de Mouloud Mammeri, Algerie.</mixed-citation></ref><ref id="scirp.85664-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Djaani, M. and Benmansour, S.F. (2011) Stabilisation des sols gonflants de la région d'In-Aménas par ajouts des liants hydrauliques (Chaux et Ciment). Mémoire de fin d’étude en vue de l’obtention du dipl&amp;ocirc;me de Master en génie civil, Université de Kasdimerbahouargla, Algerie.</mixed-citation></ref><ref id="scirp.85664-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Hachichi, A. (2009) Etude des phénomènes retrait-gonflement et stabilisation des sols gonflants de la région d’Oran. 19&lt;sup&gt;ème&lt;/sup&gt; Congrès Franais de Mécanique, Marseille.</mixed-citation></ref><ref id="scirp.85664-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Khattab, S.A. (2002) Etude multi-échelles d’un sol argileux plastique traité à la chaux. Thèse de doctorat, Université d’Orléans.</mixed-citation></ref><ref id="scirp.85664-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Cabane, N. (2004) Sols traités à la chaux et aux liants hydrauliques: Contribution à l’identification et à l’analyse des éléments perturbateurs de la stabilisation. Thèse de doctorat, Ecole Nationale Supérieure des Mines de Saint étienne.</mixed-citation></ref><ref id="scirp.85664-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">J. P. Sylvain,J.P., Aregba, A, Collart, J, Godonou,K.S. (1896) Carte géologique du Togo à l’échelle 1/500000, 1&lt;sup&gt;re&lt;/sup&gt; édition, Notice explicative.</mixed-citation></ref><ref id="scirp.85664-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Normes NF P 94-057 (1992) Analyse granulométrique des sols, méthode par sédimentation, AFNOR.</mixed-citation></ref><ref id="scirp.85664-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Normes NF P 94-051 (1993) Détermination des limites d’Atterberg, limite de liquidité à la coupelle-limite de plasticité au rouleau, AFNOR.</mixed-citation></ref><ref id="scirp.85664-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Normes NF P 94-053 (1991) Détermination de la masse volumique des sols fin en laboratoire, AFNOR.</mixed-citation></ref><ref id="scirp.85664-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Normes XP P 94-091 (1995) Essai de gonflement à l’oedomètre-détermination des déformations par chargement de plusieurs éprouvettes, AFNOR.</mixed-citation></ref><ref id="scirp.85664-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Amey, K.B., Neglo, K., Tamba, Johnson, A.K.C., Kouto, Y.E. and Nayo, E. (2014) Caractérisation physique de sables silteux au Togo. Afrique SCIENCE, 10, 53-69.  
http://www.afriquescience.info.</mixed-citation></ref><ref id="scirp.85664-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Amey, K.B., Bedja, K. and Neglo,K. (2005) Etude de l’évolution transversale des distributions différentielle et cumulative et de la classe granulaire des granulats marins du littoral togolais. J. Rech. Sci. Univ. Lomé (Togo), Série E, 7, 13-20.</mixed-citation></ref><ref id="scirp.85664-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Amey, K.B. (2006) Caractérisation des sédiments sableux du littoral togolais : expérimentation et détermination d’une formule de sable normale. Thèse de Doctorat unique en science de l’ingénieur à l’Université de Lomé (Togo).</mixed-citation></ref><ref id="scirp.85664-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">AissaMamoune, S.M., Bekkouche, A. and Djedid, A. (2001) Identification et prévision du gonflement de quelques sols de la région de Tlemcen, Algérie. Bulletin des laboratoires des ponts et chaussées, RéF. 4375, 67-75.</mixed-citation></ref><ref id="scirp.85664-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Louafi, B. and Derriche, Z. (2005) Effet d’un ajout de sable et l’influence de sa granulométrie sur les caractéristiques de gonflement d’une argile pure, Géoline-Lyon France-23&lt;sup&gt;rd&lt;/sup&gt;-25&lt;sup&gt;th&lt;/sup&gt;.</mixed-citation></ref></ref-list></back></article>