<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JBNB</journal-id><journal-title-group><journal-title>Journal of Biomaterials and Nanobiotechnology</journal-title></journal-title-group><issn pub-type="epub">2158-7027</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jbnb.2018.93013</article-id><article-id pub-id-type="publisher-id">JBNB-85509</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Surface Modification of PEEK and Its Osteoconductivity and Anti-Inflammatory Properties
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kensuke</surname><given-names>Kuroda</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kenta</surname><given-names>Igarashi</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hiroyasu</surname><given-names>Kanetaka</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Masazumi</surname><given-names>Okido</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Institute of Materials and Systems for Sustainability, Nagoya University, Nagoya, Japan</addr-line></aff><aff id="aff3"><addr-line>Liaison Center for Innovative Dentistry, Graduate School of Dentistry, Tohoku University, Sendai, Japan</addr-line></aff><aff id="aff2"><addr-line>Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Japan</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>kkuroda@numse.nagoya-u.ac.jp(KK)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>26</day><month>06</month><year>2018</year></pub-date><volume>09</volume><issue>03</issue><fpage>233</fpage><lpage>243</lpage><history><date date-type="received"><day>8,</day>	<month>April</month>	<year>2018</year></date><date date-type="rev-recd"><day>23,</day>	<month>June</month>	<year>2018</year>	</date><date date-type="accepted"><day>26,</day>	<month>June</month>	<year>2018</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Polyetheretherketone (PEEK) is known as one of the “super-engineering plastics” and is used as an intervertebral disk spacer in the body. PEEK has a hydrophobic surface (water contact angle (WCA) &gt; 80
  &#176;) and high chemical resistance, and it is thus difficult to perform any surface treatment, such as hydrophilization. In this study, we aimed to form a hydrophilic surface on PEEK without coating layers by using hydroprocessing (aqueous solution processing), and we examined the osteoconductivity and anti-inflammatory properties of surface-treated PEEK 
  <em>in </em>
  <em>vi</em>
  <em>vo </em>compared with Ti implants. The WCA value of PEEK reached 
  ~20
  &#176; using a combination of immersion in a solution of &gt;16.2 M H
  <sub>2</sub>SO
  <sub>4</sub> and ultraviolet irradiation (172 nm). In 
  <em>in vivo</em> testing, the hydrophilization of PEEK by surface modification without a coating layer improved the osteoconductivity and anti-inflammatory properties. The relationship between the bone-implant contact ratio and the WCA values of the surface-modified PEEK agreed well with that of the surface-treated Ti.
 
</p></abstract><kwd-group><kwd>Polyetheretherketone</kwd><kwd> Hydrophilization</kwd><kwd> Protein Adsorption</kwd><kwd> Osteoconductivity</kwd><kwd> Inflammatory</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Polymer materials are used in the orthopedic and dental fields as important biomaterials alongside metallic and ceramic materials. In general, when biomaterials are used in the body, it is known that the bioresponse depends on surface characteristics such as hydrophilicity [<xref ref-type="bibr" rid="scirp.85509-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.85509-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.85509-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.85509-ref4">4</xref>] . Our previous study using valve metals and their alloys showed that hydrophilic metallic surfaces have high osteoconductivity [<xref ref-type="bibr" rid="scirp.85509-ref5">5</xref>] . Many kinds of polymers have a high chemical stability as well as a hydrophobic surface. For example, polyetheretherketone (PEEK), which is used as an intervertebral disk spacer, has a hydrophobic surface (water contact angle (WCA) &gt; 80˚); however, based on our previous studies with metallic materials, this feature does not indicate that PEEK has high biocompatibility. Indeed, postoperative infection caused by a PEEK disc spacer has been reported and solutions to such potential bio-incompatibility have been proposed [<xref ref-type="bibr" rid="scirp.85509-ref6">6</xref>] . PEEK is known as one of the “super-engineering plastics” that have a high chemical resistance; consequently, a surface treatment, such as hydrophilization, is very difficult to apply in the same manner as for polytetrafluoroethylene (PTFE). Initially, hydrophobic PEEK was coated with hydroxyapatite (HAp), which was believed to be a bioactive substance [<xref ref-type="bibr" rid="scirp.85509-ref7">7</xref>] , but the adhesion of HAp on PEEK was poor. It is believed that the root of this problem is that PEEK shows very stable hydrophobicity.</p><p>Plasma irradiation is commonly used for the hydrophilization of various polymer materials [<xref ref-type="bibr" rid="scirp.85509-ref8">8</xref>] . However, the nearly line-of-sight nature of plasma irradiation and the normally relatively inhomogeneous irradiation can produce surface unevenness, thereby limiting the usefulness of this technique because many implants have a complex shape. In this study, we aimed to form a hydrophilic surface on PEEK without coating layers by using hydroprocessing (aqueous solution processing), and we examined the osteoconductivity and anti-inflammatory properties of the surface-treated PEEK compared with the surface-treated Ti implants in vivo.</p></sec><sec id="s2"><title>2. Theory of Polymer Hydrophilization</title><p>It is well known that the copolymer of polylactic acid-glycolic acid (PLGA) degrades in the body [<xref ref-type="bibr" rid="scirp.85509-ref9">9</xref>] . However, its degradability is not very fast and acceleration methods have been proposed [<xref ref-type="bibr" rid="scirp.85509-ref10">10</xref>] ; for example, it was reported that the immersion of PLGA into alkaline aqueous solution was effective in accelerating the degradation. In our preliminary experiment, a PLGA sheet was immersed in several aqueous solutions, such as distilled water (DW), and ~5 mol L<sup>−1</sup> NaOH aqueous solution (NaOHaq). <xref ref-type="fig" rid="fig1">Figure 1</xref> shows the change in the WCA of the PLGA sheet with time. The immersion in DW decreased the WCA, but not at a fast rate and the WCA value converged to ~80˚, after which it remained unchanged. After immersion in NaOHaq, the WCA decreased more quickly than in DW and converged to a smaller value. That is, the hydrophilization by hydrolysis made only very slow progress and a higher NaOH content decreased WCA more quickly; moreover, the WCA value that was reached was smaller. It is thought that the neutralization (acid-base) reaction removed the acid compound formed from the hydrolysis and this advanced the degradation of PLGA. From this experiment, we considered that at least a two-step reaction was necessary as a</p><p>trigger for the hydrophilization of the polymer, disconnection of the bonds (e.g., hydrolysis), and its acceleration. In addition, fixation of the hydrophilic group (e.g., -OH, -COOH) to the disconnected bond was an indispensable condition for hydrophilization.</p></sec><sec id="s3"><title>3. Experimental</title><sec id="s3_1"><title>3.1. Surface Modification</title><p>We previously reported that the surface roughness of implants affected osteoconductivity after implantation [<xref ref-type="bibr" rid="scirp.85509-ref11">11</xref>] . PEEK plates (f6 mm) were polished by buffing using Al<sub>2</sub>O<sub>3</sub> particles (particle size = 0.05 μm) and the surface roughness (Ra) was set as Ra/μm &lt; 0.1. Samples were immersed in ~18 M (=mol L<sup>−1</sup>) H<sub>2</sub>SO<sub>4</sub>, ~12 M HCl, ~13 M HNO<sub>3</sub>, ~17 M CH<sub>3</sub>COOH, or ~30 vol.% H<sub>2</sub>O<sub>2</sub> for up to 1 d at 30˚C for the disconnection of the ether bond in PEEK, considering the chemical resistance of PEEK. The immersed samples were picked up from the solution and rinsed in distilled water, acetone, ethanol, or toluene, respectively, and dried in vacuum. After drying, the samples were subjected to the following second step for the hydrophilization. The samples were irradiated either with ultraviolet (UV, 172, 254, or 365 nm wavelength) radiation for up to 6 h at 20˚C, or with atmospheric plasma for up to 1 h. As a storing environment for the hydrophilicity of surface-treated samples, DW, phosphate buffered saline (PBS) (−), five times concentrated PBS (−) (&#180;5 PBS (−)), and air were selected, respectively, and the hydrophilicity value of the samples was maintained. In addition, the WCA of the sample surface was controlled using the change in storing period and environment. WCA was measured using a 2-μL droplet of distilled water. The modified surfaces were analyzed using scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and Fourier transform infrared spectroscopy (FTIR) in attenuated total reflection (ATR) mode.</p></sec><sec id="s3_2"><title>3.2. Protein Adsorption Testing</title><p>In the protein adsorption testing, fibronectin and albumin were picked up as a protein that was either a cell-adhesive protein or not, respectively [<xref ref-type="bibr" rid="scirp.85509-ref12">12</xref>] . A fibronectin (~1.0 mg mL<sup>−1</sup>) or albumin (~50 mg mL<sup>−1</sup>) aqueous solution droplet (40 μL) was put on the surface of the WCA-controlled PEEK samples, respectively, and these were kept at 37˚C for up to 3 d. Then, they were rinsed out with ultrasonic cleaning in the distilled water and dried naturally. The amount of adsorbed protein was determined using FTIR in attenuated total reflection (ATR) mode. The protein content was evaluated from the peptide binding (1650 cm<sup>−1</sup>) in the protein in the FTIR spectra. The content of the different three positions was measured for each samples using calibration curve, and the mean value was calculated.</p></sec><sec id="s3_3"><title>3.3. In Vivo Testing</title><p>All the animal studies were conducted in the laboratory at HAMRI Co., Ltd., Japan, of the Association for Assessment and Accreditation of Laboratory Animal Care International (AAALAC).</p><p>1) Testing of osteoconductivity [<xref ref-type="bibr" rid="scirp.85509-ref13">13</xref>]</p><p>The sides of PEEK rods (2 mm in diameter, 5 mm in length) were polished by buffing using 0.05 μm Al<sub>2</sub>O<sub>3</sub> particles. Hydrophilic PEEK rods (WCA = 85˚) were prepared in a combination of immersion in 16.2 M H<sub>2</sub>SO<sub>4</sub> for 5 s at 30˚C and UV irradiation (172 nm) for 3 h. For the formation of the protein-adsorbed samples, hydrophilic PEEK samples were immersed in 1.0 mg mL<sup>−1</sup> fibronectin aqueous solution for 48 h at 37˚C. Next, they were rinsed with ultrasonic cleaning in the distilled water and dried naturally. All the surface-treated rod samples (n = 5) before and after protein adsorption were implanted in rat tibia for 14 d for evaluation of osteoconductivity. The samples were longitudinally sliced and stained with toluidine blue. The interface between the implant and the cortical bone, as well as the cancerous bone, was observed by optical microscopy. The sum of the linear bone contact with the implant surface was measured and was expressed as a percentage over the entire implant length (the bone-implant contact ratio, BIC) in the cancerous bone and in the cortical bone parts. Significant differences in BIC were analyzed statistically using the Tukey-Kramer method [<xref ref-type="bibr" rid="scirp.85509-ref14">14</xref>] .</p><p>2) Testing of anti-inflammatory properties</p><p>PEEK rods of 1 mm in diameter and 5 mm in length were used in the anti-inflammatory testing. The method of WCA control and fibronectin adsorption was the same as in the osteoconductivity testing. The surface-treated samples (n = 3) were implanted in the subcutaneous of the back of rats by inoculation using an injection needle and the rats were sacrificed at 14 d post implantation. Because serious inflammation, necrosis, suppuration, and bleeding were not detected around the surrounding tissue of implants by visual observation, tissue samples were fixed in 10% formalin, and embedded in methyl methacrylate (MMA) polymer. The samples were sliced and stained with toluidine blue. Optical microscope observation of the interface between the implanted and the surrounding tissue revealed whether inflammatory cells such as lymphocytes and neutrophils were present, as well as a new generation of vascular, and formation of a fibrous capsule film. The capsule film thickness of the eight positions was measured for each samples, and the mean value was expressed as an index of anti-inflammatory properties.</p></sec></sec><sec id="s4"><title>4. Results and Discussion</title><sec id="s4_1"><title>4.1. Surface Modification</title><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows photographs taken after immersion in several aqueous solutions and washing in distilled water. The immersion in 12 M HCl, 13 M HNO<sub>3</sub>, 17 M CH<sub>3</sub>COOH, and 30 vol.% H<sub>2</sub>O<sub>2</sub> did not change the surface morphology of PEEK. The WCA values were 81˚, 84˚, 80˚, and 83˚, respectively, and they did not increase or decrease dramatically from the as-polished PEEK (~85˚). Immersion in H<sub>2</sub>SO<sub>4</sub> had a clear effect on the surface appearance. In particular, 18 M H<sub>2</sub>SO<sub>4</sub> attacked the surface and the color turned white from beige, and the Ra value increased from 0.05 to 0.44 μm. For immersion in 16.8 M H<sub>2</sub>SO<sub>4</sub>, SEM observation confirmed the attack, although discoloration and Ra change did not occur. For the immersion in less than 15 M, no changes were observed. <xref ref-type="fig" rid="fig3">Figure 3</xref> shows FTIR spectra of samples after 18 M H<sub>2</sub>SO<sub>4</sub> immersion (<xref ref-type="fig" rid="fig3">Figure 3</xref>(b)) and washing in DW (<xref ref-type="fig" rid="fig3">Figure 3</xref>(c)). <xref ref-type="fig" rid="fig3">Figure 3</xref> indicates that the immersion in H<sub>2</sub>SO<sub>4</sub> broke the</p><p>ether bond, the C-C single bond, and the C=C double bond, and increased the sulfo group. Because the subsequent washing process decreased the sulfo group, it was thought that the WCA value did not decrease after immersion in H<sub>2</sub>SO<sub>4</sub>, which in any case satisfied the first step for polymer hydrophilization, that is, the disconnection of the bonds.</p><p>As a second step, UV (172 nm) irradiation (&gt;10 mW cm<sup>−2</sup>, with 3 mm distance) and atmospheric plasma irradiation (500 W, 50 mm distance) were selected and applied on the solution-treated samples: immersion in 16.2 M H<sub>2</sub>SO<sub>4</sub> for 5 s and rinsing in DW. With atmospheric plasma, the WCA value decreased rapidly and reached a constant WCA of ~10˚ in 10 min, regardless of the first step. FTIR showed that there was no change in the surface functional group by the plasma treatment (<xref ref-type="fig" rid="fig3">Figure 3</xref>(e)), and therefore it was thought that radicals might contribute to hydrophilization. However, the hydrophilicity formed by plasma irradiation, could not be maintained, and the WCA value rose rapidly in 1 d (<xref ref-type="fig" rid="fig4">Figure 4</xref>). In contrast, it took 1 - 2 h for the solution-treated samples to reach a constant WCA of ~20˚ under UV irradiation, and the Ra value was the same as after H<sub>2</sub>SO<sub>4</sub> immersion (Ra = 0.05 μm). FTIR showed that the UV irradiation created a carboxyl group. By examination of UV irradiation under different partial pressure environments of CO<sub>2</sub> (Ar or CO<sub>2</sub> atmosphere), we determined that this carboxyl group was formed from CO<sub>2</sub> in air. The UV treatment on the as-polished sample gave a surface with ~40˚ and a longer irradiation time did not result in further reduction in WCA. The hydrophilicity could be kept for</p><p>7 d by storing in &#180;5 PBS (−) in the same manner as hydrophilic Ti and its alloy samples [<xref ref-type="bibr" rid="scirp.85509-ref15">15</xref>] . It is thought that ions in &#180;5 PBS (−), such as Na<sup>+</sup>, were adsorbed on the hydrophilic PEEK surface. Thus, in the following hydrophilization experiment, PEEK was immersed in 16.2 M H<sub>2</sub>SO<sub>4</sub> for 5 s and rinsed in DW, and then irradiated with UV (172 nm) for more than 3 h in air. To maintain hydrophilicity, the surface-treated PEEK was stored in &#180;5 PBS (−).</p></sec><sec id="s4_2"><title>4.2. Evaluation of Osteoconductivity</title><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows the relationship between the BIC value of surface-treated PEEK and WCA compared with WCA-controlled Ti. The BIC value of as-polished PEEK was very low, and a fibrous capsule film formed over the entire surface in some samples. In contrast, hydrophilic PEEK had a high BIC value. This tendency agreed well with our results for surface-treated Ti [<xref ref-type="bibr" rid="scirp.85509-ref15">15</xref>] . The hydrophilization of PEEK dramatically improved the osteoconductivity, meaning that the osteoconductivity strongly depended on the surface property and not on the implant materials themselves. Based on our previous work [<xref ref-type="bibr" rid="scirp.85509-ref16">16</xref>] , we believed that the osteoconductivity was not directly affected by the WCA of the implants. In other words, it was thought that the WCA affected protein adsorption, which in turn controlled the osteoconductivity of the implants. The amount of adsorbed protein (fibronectin and albumin) with respect to the WCA value is shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>(a) &amp; <xref ref-type="fig" rid="fig6">Figure 6</xref>(b). Neither protein was adsorbed on the as-polished PEEK surface. In contrast, on surface-treated PEEK, the proteins were adsorbed,</p><p>depending on the WCA value. This tendency agreed well with our results for surface-treated Ti [<xref ref-type="bibr" rid="scirp.85509-ref15">15</xref>] . The BIC value of the fibronectin-adsorbed samples (n = 5) on the hydrophilic samples (n = 3) was also high, and the same level of hydrophilic sample, in spite that the fibronectin-adsorbed sample did not have a hydrophilic surface (WCA = 48˚). This also supports the notion that the osteoconductivity was not directly affected by the WCA of implants.</p></sec><sec id="s4_3"><title>4.3. Evaluation of Anti-Inflammatory Properties</title><p><xref ref-type="fig" rid="fig7">Figure 7</xref> shows photographs inside of the stripped skin and optical micrographs of surface-treated PEEK samples. Serious inflammation and necrosis were not detected around the surrounding tissue of implants. A fibrous capsule film formed over the entire surface in all samples, and the inflammatory reaction occurred over the whole surface of all samples. The thickness of the capsule film was used as an index for the evaluation of anti-inflammatory properties. <xref ref-type="fig" rid="fig8">Figure 8</xref> shows the thickness of the capsule film formed on the implants. On the</p><p>as-polished sample, a thick capsule film was formed, suggesting that the inflammation was strong, as reported [<xref ref-type="bibr" rid="scirp.85509-ref17">17</xref>] . However, the inflammation was weaker on the surface-treated PEEK, which was not related to the WCA value. In the implantation of the fibronectin-adsorbed PEEK samples on the hydrophilic surface in advance, the inflammation was not suppressed further. It is noteworthy that the surface treatment can suppress the inflammation without an anti-inflammatory drug, compared with as-polished PEEK.</p></sec></sec><sec id="s5"><title>5. Conclusion</title><p>The WCA value of PEEK reached ~20˚ using a combination of immersion in &gt;16.2 M H<sub>2</sub>SO<sub>4</sub> and UV irradiation (172 nm). The immersion of the surface-treated PEEK in &#180;5 PBS (−) maintained the hydrophilic WCA. Although as-polished PEEK could not adsorb protein, hydrophilization gave rise to protein adsorption. In vivo, the hydrophilization of PEEK by surface modification without a coating layer improved the osteoconductivity and anti-inflammatory properties. The relationship between BIC and WCA values of surface-modified PEEK agreed well with that of the surface-treated Ti.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This research was financial supported partially by JSPS KAKENHI (Grant-in-Aid for Scientific Research (A) 15H02310 and (B) 25289248), and Joint Research Project on Life Innovation Materials by MEXT.</p></sec><sec id="s7"><title>Conflicts of Interest</title><p>The authors declare that there are no conflicts of interest regarding the publication of this paper.</p></sec><sec id="s8"><title>Cite this paper</title><p>Kuroda, K., Igarashi, K., Kanetaka, H. and Okido, M. (2018) Surface Modification of PEEK and Its Osteoconductivity and Anti-Inflammatory Properties. Journal of Biomaterials and Nanobiotechnology, 9, 233-243. https://doi.org/10.4236/jbnb.2018.93013</p></sec></body><back><ref-list><title>References</title><ref id="scirp.85509-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Buser, D., Broggini, N., Wieland, M., Schenk, R.K., Denzer, A.J., Cochran, D.L., Hoffmann, B., Lussi, A. and Steinemann, S.G. (2004) Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface. Journal of Dental Research, 83, 529-533. https://doi.org/10.1177/154405910408300704</mixed-citation></ref><ref id="scirp.85509-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Cochran, D.L., Buser, D., ten Bruggenkate, C.M., Weingart, D., Taylor, T.M., Bernald, J.P., Peters, F. and Simpson, J.P. (2002) The Use of Reduced Healing Times on ITI&lt;sup&gt;&amp;#174&lt;/sup&gt; Implants with a Sandblasted and Acid-Etched (SLA) Surface: Early Results from Clinical Trials on ITI&lt;sup&gt;&amp;#174&lt;/sup&gt; SLA Implants. Clinical Oral Implants Research, 13, 144-153. https://doi.org/10.1034/j.1600-0501.2002.130204.x</mixed-citation></ref><ref id="scirp.85509-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Eriksson, C., Nygren, H. and Ohlson, K. (2004) Implantation of Hydrophilic and Hydrophobic Titanium Discs in Rat Tibia: Cellular Reactions on the Surfaces during the First 3 Weeks in Bone. Biomater, 25, 4759-4766.  
https://doi.org/10.1016/j.biomaterials.2003.12.006</mixed-citation></ref><ref id="scirp.85509-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Park, J.-W., Park, K.-B. and Suh, J.-Y. (2007) Effects of Calcium Ion Incorporation on Bone Healing of Ti6Al4V Alloy Implants in Rabbit Tibiae. Biomater, 28, 3306-3313. https://doi.org/10.1016/j.biomaterials.2007.04.007</mixed-citation></ref><ref id="scirp.85509-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Zuldesmi, M., Waki, A., Kuroda, K. and Okido, M. (2013) High Osteoconductive Surface of Pure Titanium by Hydrothermal Treatment. Journal of Biomaterials and Nanobiotechnology, 4, 284-290. https://doi.org/10.4236/jbnb.2013.43036</mixed-citation></ref><ref id="scirp.85509-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Toth, J.M., Wang, M., Estes, B.T., Scifert, J.L., Seim, H.B. and Turmer, A.S. (2006) Polyetheretherketone as a Biomaterial for Spinal Applications. Biomater, 27, 324-334. https://doi.org/10.1016/j.biomaterials.2005.07.011</mixed-citation></ref><ref id="scirp.85509-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Suzuki, N., Umeda, T., Sumi, T., Horikoshi, S., Kuwahara, H., Toyama, T., Musha, Y. and Itatani, K. (2016) Rapid Formation of Hydroxyapatite Layer on Polyetheretherketone by Vacuum Ultraviolet Irradiation and Microwave Heating Techniques. Journal of the Ceramic Society of Japan, 124, 49-54.  
https://doi.org/10.2109/jcersj2.15209</mixed-citation></ref><ref id="scirp.85509-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Chvatalova, L., Cermak, R., Mracek, A., Grulich, O., Vesel, A., Ponizil, P., Minarik, A., Cvelbar, U., Benicek, L. and Sajdl, P. (2012) The Effect of Plasma Treatment on Structure and Properties of Poly(1-butene) Surface. European Polymer Journal, 48, 866-874. https://doi.org/10.1016/j.eurpolymj.2012.02.007</mixed-citation></ref><ref id="scirp.85509-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Caffesse, R.G., Nasjleti, C.E., Morrison, E.C. and Sanchez, R. (1994) Guided Tissue Regeneration: Comparison of Bioabsorbable and Non-Bioabsorbable Membranes. Histologic and Histometric Study in Dogs. Journal of Periodontology, 65, 583-591.  
https://doi.org/10.1902/jop.1994.65.6.583</mixed-citation></ref><ref id="scirp.85509-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Tsuchiya, S., Ohmori, M., Hara, K., Fujio, M., Ikeno, M., Hibi, H. and Ueda, M. (2015) An Experimental Study on Guided Bone Regeneration Using a Polylactide-co-glycolide Membrane-Immobilized Conditioned Medium. The International Journal of Oral &amp; Maxillofacial Implants, 30, 1175-1186.  
https://doi.org/10.11607/jomi.3915</mixed-citation></ref><ref id="scirp.85509-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Yamamoto, D., Kawai, I., Kuroda, K., Ichino, R., Okido, M. and Seki, A. (2011) Osteoconductivity of Anodized Titanium with Controlled Micron-Level Surface Roughness. Materials Transactions, 52, 1650-1654.  
https://doi.org/10.2320/matertrans.M2011049</mixed-citation></ref><ref id="scirp.85509-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Porté-Durrieu, M.C., Guillemota, F., Pallu, S., Labrugère, C., Brouillaud, B., Bareille, R., Amédée, J., Barthe, N., Dard, M. and Baquey, Ch. (2004) Cyclo-(DfKRG) Peptide Grafting onto Ti-6Al-4V: Physical Characterization and Interest towards Human Osteoprogenitor Cells Adhesion. Biomater, 25, 4837-4846.  
https://doi.org/10.1016/j.biomaterials.2003.11.037</mixed-citation></ref><ref id="scirp.85509-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Kuroda, K., Nakamoto, S., Miyashita, Y., Ichino, R. and Okido, M. (2006) Osteoinductivity of HAp Films with Different Surface Morphology Coated by the Thermal Substrate Method in Aqueous Solutions. Materials Transactions, 47, 1391-1394.  
https://doi.org/10.2320/matertrans.47.1391</mixed-citation></ref><ref id="scirp.85509-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Kramer, C.Y. (1956) Extension of Multiple Range Tests to Group Means with Unequal Numbers of Replications. Biometrics, 12, 307-310.  
https://doi.org/10.2307/3001469</mixed-citation></ref><ref id="scirp.85509-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Zuldesmi, M., Waki, A., Kuroda, K. and Okido, M. (2014) Enhancement of Valve Metal Osteoconductivity by One-Step Hydrothermal Treatment. Materials Science and Engineering: C, 42, 405-411. https://doi.org/10.1016/j.msec.2014.05.049</mixed-citation></ref><ref id="scirp.85509-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Kuroda, K. and Okido, M. (2015) A New Approach for Controlling Osteoconductivity of Valve Metals Based on TiO2 Coatings on Ti Substrates. Materials Technology, 30, B13-B20. https://doi.org/10.1179/1753555714Y.0000000221</mixed-citation></ref><ref id="scirp.85509-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Toth, J.M., Wang, M., Estes, B.T., Scifert, J.L., Seim III, H.B. and Turner, A.S. (2006) Polyetheretherketone as a Biomaterial for Spinal Applications. Biomater, 27, 324-334. https://doi.org/10.1016/j.biomaterials.2005.07.011</mixed-citation></ref></ref-list></back></article>