<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">IJAMSC</journal-id><journal-title-group><journal-title>International Journal of Analytical Mass Spectrometry and Chromatography</journal-title></journal-title-group><issn pub-type="epub">2332-1768</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ijamsc.2018.62002</article-id><article-id pub-id-type="publisher-id">IJAMSC-85088</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Rapid and Reproducible Dibutylation Derivatization Coupled with Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry for the Simultaneous Determination of Dopamine, Norepinephrine and 5-Hydroxytryptamine in Rat Brain Microdialysates
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jinlian</surname><given-names>Lu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Weimin</surname><given-names>Hu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Weiqun</surname><given-names>Cao</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Sitan</surname><given-names>Xie</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Zhiyu</surname><given-names>Li</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yi</surname><given-names>Tao</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xin</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Bioanalytical Services Unit, Lab-Testing Division, WuXi AppTec Co., Ltd., Shanghai, China</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>xie_sitan@wuxiapptec.com(SX)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>04</day><month>06</month><year>2018</year></pub-date><volume>06</volume><issue>02</issue><fpage>21</fpage><lpage>36</lpage><history><date date-type="received"><day>14,</day>	<month>March</month>	<year>2018</year></date><date date-type="rev-recd"><day>2,</day>	<month>June</month>	<year>2018</year>	</date><date date-type="accepted"><day>5,</day>	<month>June</month>	<year>2018</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  A rapid and reproducible method has been developed for the simultaneous quantification of dopamine (DA), norepinephrine (NE), and serotonin (5-HT) in rat brain microdialysates. Derivatization was processed through reductive amination with butyraldehyde and sodium cyanoborohydride at 60℃ for 80 min incubation. Dibutylated monoamine neurotransmitters (MANTs) were directly analyzed with ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The chromatographic run time was shorter (2.1 min/sample) than previous studies [15] [18] [20]. Good linearity (R2 &gt; 0.99) was obtained for DA, NE and 5-HT in the range of 25 - 5000 pg/mL, 5 - 1000 pg/mL and 2.5 - 500 pg/mL, respectively. Acceptable precision (CV, 8.5% - 13.4%) as well as accuracy (recovery, 94.1% - 106.8%) could be acquired by analysis of six batches of quality control samples (QCs) at four different concentrations, which demonstrated the reliability and reproducibility of current method. This method was successfully applied to the simultaneous determination of DA, NE and 5-HT in rat brain microdialysates, where basal levels as well as elevated levels after dosing with amphetamine (AMPH) were quantified for all three MANTs. This study provides a simple and rapid way to analyze MANTs in the biofluid in the future.
 
</p></abstract><kwd-group><kwd>Derivatization</kwd><kwd> Microdialysis</kwd><kwd> Monoamine Neurotransmitters</kwd><kwd> LC-MS/MS</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Abnormalities in neurotransmitter synthesis, breakdown and transport represented a wide group of neurological syndrome [<xref ref-type="bibr" rid="scirp.85088-ref1">1</xref>] . Monoamine neurotransmitters (MANTs), including dopamine (DA), norepinephrine (NE) and serotonin (5-HT) have been proved to be highly correlated with a number of central nervous system symptoms, ranging from abnormal behavior [<xref ref-type="bibr" rid="scirp.85088-ref2">2</xref>] , emotional fluctuation [<xref ref-type="bibr" rid="scirp.85088-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref4">4</xref>] , to a wide range of neurological diseases [<xref ref-type="bibr" rid="scirp.85088-ref1">1</xref>] , such as depression [<xref ref-type="bibr" rid="scirp.85088-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref6">6</xref>] , Parkinson’s disease [<xref ref-type="bibr" rid="scirp.85088-ref7">7</xref>] , Huntingdon’s disease [<xref ref-type="bibr" rid="scirp.85088-ref8">8</xref>] and Alzheimer’s disease [<xref ref-type="bibr" rid="scirp.85088-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref11">11</xref>] . Therefore, in vivo detection of changes in MANTs in the brain was important for the elucidation of disease pathology, clinical diagnosis and evaluation of new treatment strategies of such disorders [<xref ref-type="bibr" rid="scirp.85088-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref12">12</xref>] .</p><p>Microdialysis was one of the few techniques that enabled continuous quantification of small molecules in the cerebrospinal fluid (CSF) of behaving animals [<xref ref-type="bibr" rid="scirp.85088-ref13">13</xref>] , such as neurotransmitters and peptides. Slow perfusate flow rates were required to assure adequate relative recovery of an analyte in vivo, but would result in small sample collection volume or insufficient temporal resolution [<xref ref-type="bibr" rid="scirp.85088-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref14">14</xref>] . In most of the previous studies, twenty to fifty μL of rat brain microdialysates were collected every 10 to 30 min at the perfusion flow rate of 1.0 - 2.0 &#181;L/min [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] , where corresponding relative recoveries were between 50% and 70% [<xref ref-type="bibr" rid="scirp.85088-ref14">14</xref>] . If the sample volume for bioanalysis could be further reduced, better temporal resolution or larger relative recovery would be acquired through shortening the sample collection interval or lowering the perfusate flow rate. Additionally, the remaining volume of the sample could be reserved for future reanalysis. The basal levels of DA, NE and 5-HT in rat brain microdialysate were typically in the range of tens to thousands of pictogram per milliliter [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] . Therefore, it is necessary to establish a sensitive bioanalytical method for monitoring low basal levels of MANTs with the small volume of rat brain microdialysate.</p><p>Various methods have been developed for the quantitative determination of MANTs. High performance liquid chromatography (HPLC) coupled with various detection techniques including electrochemical detection (EC) [<xref ref-type="bibr" rid="scirp.85088-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref29">29</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref31">31</xref>] , fluorescence-based detection (FL) [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref33">33</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref34">34</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref35">35</xref>] , chemiluminescence detection (CL) [<xref ref-type="bibr" rid="scirp.85088-ref36">36</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref37">37</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref38">38</xref>] and mass spectrometry-based detection (MS) [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] have been presented. HPLC-EC offered relatively simple and sensitive methods, however, system robustness, reproducibility and specificity became challenges for this method [<xref ref-type="bibr" rid="scirp.85088-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref31">31</xref>] . And, it was difficult for HPLC-EC to simultaneously determine DA, NE and 5-HT within a single run [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] . Pre-column derivatization coupled with HPLC-FL provided high sensitivity, but it required long separation time (7 - 40 min/sample) to effectively separate target analytes from interferences due to the complex nature of biological matrices [<xref ref-type="bibr" rid="scirp.85088-ref34">34</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref35">35</xref>] . HPLC-CL could be carried out without pre-column derivatization, but this method was limited by its linear range and relatively long separation time (~10 - 20 min/sample) [<xref ref-type="bibr" rid="scirp.85088-ref36">36</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref38">38</xref>] . HPLC-MS/MS was a highly specific analytical method due to the additional structural information provided by ion fragmentation patterns [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] . However, HPLC-MS/MS without pre-column derivatization either failed to provide enough sensitivity for detection basal levels of MANTs [<xref ref-type="bibr" rid="scirp.85088-ref21">21</xref>] , or required long separation time (~30 min/sample) [<xref ref-type="bibr" rid="scirp.85088-ref22">22</xref>] .</p><p>Chemical derivatization of the MANTs was widely applied to improve the LC-MS/MS detection, primarily through a reaction targeting the amine group and/or phenol-hydroxyl groups. The derivatization reagents utilized in previous studies could be generally characterized into three groups: acyl chlorides [<xref ref-type="bibr" rid="scirp.85088-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] , sulfonyl chlorides [<xref ref-type="bibr" rid="scirp.85088-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref25">25</xref>] and aldehyde [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref40">40</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref41">41</xref>] . Acyl chlorides and sulfonyl chlorides reacted not only with amines but also with phenol-hydroxyl groups due to their strong nucleophilicity [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref24">24</xref>] . Therefore, it was possible to detect high-level background noise if the derivatization was not sufficient. Additionally, the hydrolysis products of acyl- or sulfonyl chlorides [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] would affect the derivatization efficiency. Sometimes, extra steps such as synthesis of the derivatization reagents [<xref ref-type="bibr" rid="scirp.85088-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] or ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLIME) [<xref ref-type="bibr" rid="scirp.85088-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] were performed before or after derivatization. Furthermore, acyl chloride and sulfonyl chloride were environmental unfriendly derivatization reagents. Derivatization where two methyl groups [<xref ref-type="bibr" rid="scirp.85088-ref41">41</xref>] or two ethyl groups [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] were added onto the amine groups via step-wise Schiff base reaction offered a fast and simple experimental procedure. Little interference and low-level background noise were observed [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] , probably due to the relatively simple reaction pathway between aldehydes and the amine groups of MANTs.</p><p>Due to the highly hydrophobic nature of the derivatization reagents, long elution time was usually used with reverse phase liquid chromatography (RPLC) separation (~3.5 to ~30 min/sample) [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] . The pharmaceutical industry had brought constant pressure on bioanalysts for shorter timelines, accompanied by the increased number of biological samples [<xref ref-type="bibr" rid="scirp.85088-ref42">42</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref43">43</xref>] . The average run time of approximately 2 min/sample has become a norm both in the literature [<xref ref-type="bibr" rid="scirp.85088-ref43">43</xref>] and in our own experience in the environment of a contract research organization (CRO). In the search for better derivatization reagents, it has been shown that longer alkyl chain length on the derivatization reagent could improve the LC behavior and sensitivity of amino acids [<xref ref-type="bibr" rid="scirp.85088-ref44">44</xref>] . However, on the other hand, more hydrophobic derivatization reagent would lead to longer retention time and poor solubility in the aqueous phase, which meant that an additional liquid-liquid extraction (LLE) step would be required. Therefore, the type and the hydrophobicity of the derivatization reagent needed to be carefully tuned.</p><p>In this work, we reported a rapid and reproducible method for the simultaneous determination of three MANTs, including DA, NE and 5-HT in rat brain microdialysate. Microdialysis samples were firstly derivatized with n-butyraldehyde and sodium cyanoborohydride at 60˚C for 80 min, and further analyzed with a rapid (2.1 min/sample) UPLC-MS/MS protocol. In a practical example, both basal and elevated levels of MANTs were successfully quantified over a 4-hour time course before and after administration of amphetamine (AMPH).</p></sec><sec id="s2"><title>2. Experiment</title><sec id="s2_1"><title>2.1. Chemicals and Materials</title><p>Dopamine hydrochloride (DA・HCl), (-)-norepinephrine (NE), serotonin hydrochloride (5-HT・HCl), L-ascorbic acid, sodium cyanoborohydride, formic acid, acetonitrile, methanol, ammonium acetate, paraformaldehyde, benzaldehyde and butyraldehyde were purchased from Sigma-Aldrich (Sanit Louis, MO, USA). Stable-isotopic labeling internal standards 2-(3,4-dihydroxyphenyl)ethyl-1,1,2,2-d<sub>4</sub>-amine hydrochloride, (&#177;)-norepinephrine-2,5,6,α,β,β-d<sub>6</sub> hydrochloride and serotonin-α,α,β,β,-d<sub>4</sub> creatinine sulfate complex (free base forms of the three internal standards were abbreviated as d<sub>4</sub>-DA, d<sub>6</sub>-NE and d<sub>4</sub>-5-HT, respectively) were supplied by C/D/N Isotopes Inc. (Quebec, Canada). Ethanol absolute was supplied by Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Artificial cerebrospinal fluid (aCSF) was purchased from Harvard Apparatus (Holliston, MA, USA). Water was purified with an ELGA water purification system (ELGA, Bucks, UK).</p></sec><sec id="s2_2"><title>2.2. Preparation of Solutions</title><p>Neurotransmitter standards DA・HCl, NE, and 5-HT・HCl were dissolved in 25 mM L-ascorbic acid in purified water: MeOH (v; v, 4:1) to obtain 1 mg/mL solutions of DA, NE, and 5-HT (concentrations were calculated in their free base forms), respectively. One mg/mL solutions were further multi-step diluted with 25 mM L-ascorbic acid in purified water: MeOH (v; v, 4:1) to generate stock solutions of DA, NE and 5-HT with the concentrations of 200 ng/mL, 20 ng/mL and 20 ng/mL, respectively. Calibration standards (CSs) were obtained by serial dilution of each stock solution with aCSF to the following concentrations: DA (25 pg/mL, 50 pg/mL, 100 pg/mL, 250 pg/mL, 500 pg/mL, 1000 pg/mL, 2500 pg/mL and 5000 pg/mL), NE (5 pg/mL, 10 pg/mL, 20 pg/mL, 50 pg/mL, 100 pg/mL, 200 pg/mL, 500 pg/mL and 1000 pg/mL), and 5-HT (2.5 pg/mL, 5 pg/mL, 10 pg/mL, 25 pg/mL, 50 pg/mL, 100 pg/mL, 250 pg/mL and 500 pg/mL). Quality control samples (QCs) were prepared by diluting stock solutions with aCSF to four different concentrations (DA: 25 pg/mL, 75 pg/mL, 400 pg/mL and 4000 pg/mL; NE: 5 pg/mL, 15 pg/mL, 80 pg/mL and 800 pg/mL; 5-HT: 2.5 pg/mL, 7.5 pg/mL, 40 pg/mL and 400 pg/mL), representing the limits of detection (LODs), low, medium and high concentrations of the calibration range. Internal standard (IS) solutions were prepared by individually dissolving salt forms of d<sub>4</sub>-DA, d<sub>6</sub>-NE, and d<sub>4</sub>-5-HT in 25 mM L-ascorbic acid in purified water: MeOH (v;v, 4:1) to the concentration of 1 mg/mL (concentrations were calculated in their free base forms). Aliquot of each IS solution was further diluted with ethanol to obtain a mixture of d<sub>4</sub>-DA, d<sub>6</sub>-NE and d<sub>4</sub>-5-HT with the concentrations of 5 ng/mL, 0.5 ng/mL and 0.5 ng/mL, respectively.</p></sec><sec id="s2_3"><title>2.3. Derivatization Neurotransmitters with Butyraldehyde</title><p>Ten μL of CSs, QCs, or microdialysate sample was transferred into a vial containing 10 μL of IS mixture, 25 μL of sodium cyanoborohydride solution (1.5 mg/mL in ethanol) and 25 μL of butyraldehyde: ethanol (v: v, 2:98). The mixture was vortexed well and incubated in 60˚C water bath for 80 min, and was further analyzed by ultra-high performance liquid chromatography?tandem mass spectrometry (UPLC-MS/MS).</p></sec><sec id="s2_4"><title>2.4. Method Validation</title><p>In order to evaluate the linearity and sensitivity of the proposed method, CSs of DA (25 - 5000 pg/mL), NE (5 - 1000 pg/mL) and 5-HT (2.5 - 500 pg/mL) were prepared and derivatized according to the method above (Section 2.2 and Section 2.3). The calibration curves were constructed by plotting the peak-area ratio (analyte/IS) against the spiked concentration of analyte in CSs with duplicate measurements using linear regression. The limits of detection (LODs) were defined as the concentration with the signal-to-noise ratio greater than 3 (S/N &gt; 3). The accuracy and precision were assessed by the recovery and coefficient of variation (CV, %) of QCs at four different concentrations. QCs at each concentration level were paralleled prepared in six replications on the day of analysis. The recovery was calculated by (calculated analyte concentration/nominal analyte concentration) &#215; 100%.</p></sec><sec id="s2_5"><title>2.5. In Vivo Microdialysis Sampling</title><p>Male Sprague-Dawley rat (body weight 280 - 300 g) was provided by SLAC National Accelerator laboratory (CA, USA). The room temperature of animal lab was 20˚C -25˚C and humidity was 40% - 70%. Animal was allowed free access to food and water. Animal was anesthetized with pentobarbital sodium (50 mg/kg, intraperitoneal). BASi<sup>&#210;</sup> BR-2 (2 mm membrane) brain microdialysis probes (Bregma polyacrylonitrile membrane, 30 KDa, 320 &#181;m OD) (BASi corporate, IN, USA) was implanted with its tip at the upper limit of the striatum (coordinate in mm from Bregma: AP: +1.5; ML: +3.0; DV: −4.75). The probe was perfused with aCSF at 1.5 μL/min. After three days equilibration, microdialysis sampling was performed. Three consecutive microdialysate samples were collected at an interval of 20 min to determine the basal levels of DA, NE and 5-HT. Next, AMPH was intraperitoneally introduced at the concentration of 2 mg/kg. The concentration of AMPH, DA, NE and 5-HT were continuously monitored during a 220 min time course. Though 30 μL of microdialysate was collected every 20 min, only 10 μL was used for derivatization. The microdialysates were stored at −80˚C for future analysis. All the animal experiments were operated according to local ethical review and national legislation.</p></sec><sec id="s2_6"><title>2.6. Sample Preparation for AMPH Analysis in rat Brain Microdialysis</title><p>An aliquot of 3 &#181;L brain microdialysate was protein precipitated with 60 &#181;L acetonitrile containing 100 ng/mL labetalol as IS. The mixture was vortexed well for 1 min and centrifuged at 13,000 rpm for 15 min at 4˚C. Twenty-five &#181;L of supernatant was transferred into a new tube and the solvents were blow-dried under N<sub>2</sub>. The residue was then reconstituted with 50 &#181;L purified water. The solution was vortexed well and centrifuged at 13,000 rpm for 15 min at 4˚C. Seven &#181;L of supernatant was injected for UPLC-MS/MS analysis of AMPH.</p></sec><sec id="s2_7"><title>2.7. Ultra-High-Performance Liquid Chromatography/Tandem Mass Spectrometry</title><p>Neurotransmitter analysis was carried out with a QTRAP<sup>&#210;</sup> 5500 mass spectrometer (Sciex, MA, USA) connected to an ACQUITY UPLC system (Waters, MA, USA) via an electrospray ionization (ESI) source. Separation protocol using an ACQUITY UPLC BEH C18 column (2.1 &#215; 50 mm, 1.7 μm, Waters) was applied. The mobile phase gradient was set at 0.6 mL/min and 97% A for the first 0.2 min, and a linear gradient to 20% A at 1.2 min, and then to 2% A at 1.3 min, held 0.6 min, and returned to 97% A for 0.2 min to re-equilibrate the column, where A was acetonitrile:purified water (v: v, 5:95) containing 0.025% formic acid and 1 mM ammonium acetate and B was acetonitrile containing 0.025% formic acid and 1 mM ammonium acetate. The elution between 0.7 min and 1.0 min was flew into mass spectrometer, while the elution before 0.7 min and after 1.0 min were went to waste. Column temperature was 45˚C. The mass spectrometer was conducted in the positive mode with MRM transition. ESI settings were: source temperature was 600˚C, curtain gas was 40 psi, nebulizer gas pressure was 40 psi, auxiliary gas pressure was 60 psi and electrospray capillary voltage was 4.6 kV. MRM transition monitoring conditions were optimized for each compound and IS, and were summarized in <xref ref-type="table" rid="table1">Table 1</xref>. A 3.5 min separation protocol with a 3 μm-particle size, 2.1 &#215; 100 mm ACE AQ column (Advanced Chromatography Technologies Ltd, Scotland) was applied for monitoring AMPH. The mobile phase gradient was set at 0.45 mL/min and 5% B for the first 0.3 min, and a linear gradient to 60% B at 2 min, and then to 95% B at 2.3 min, held 0.4 min, and returned to 5% B for 0.8 min to re-equilibrate the column, where A and B were consistent with the mobile phases utilized for derivatized MANTs. Column temperature was 45˚C. The mass spectrometer was conducted in the positive mode with MRM transition. ESI settings were: source temperature was 550˚C, curtain gas was 40 psi, nebulizer gas pressure was 50 psi and auxiliary gas pressure was 50 psi. MRM analysis parameters for AMPH were</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Parameters of derivatized DA, NE and 5-HT and corresponding IS in the MRM analysis. DP: declustering potential. CE: collision energy</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Compound</th><th align="center" valign="middle" >Q1 Mass (m/z)</th><th align="center" valign="middle" >Q3 Mass (m/z)</th><th align="center" valign="middle" >Dwell Time (msec)</th><th align="center" valign="middle" >DP (eV)</th><th align="center" valign="middle" >CE (eV)</th><th align="center" valign="middle" >Retention time (min)</th></tr></thead><tr><td align="center" valign="middle" >DA</td><td align="center" valign="middle" >266.2</td><td align="center" valign="middle" >137.2</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >0.89</td></tr><tr><td align="center" valign="middle" >NE</td><td align="center" valign="middle" >282.2</td><td align="center" valign="middle" >264.3</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >0.86</td></tr><tr><td align="center" valign="middle" >5-HT</td><td align="center" valign="middle" >289.1</td><td align="center" valign="middle" >142.1</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >23</td><td align="center" valign="middle" >0.93</td></tr><tr><td align="center" valign="middle" >d<sub>4</sub>-DA</td><td align="center" valign="middle" >270.2</td><td align="center" valign="middle" >141.3</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >0.89</td></tr><tr><td align="center" valign="middle" >d<sub>6</sub>-NE</td><td align="center" valign="middle" >288.2</td><td align="center" valign="middle" >270.3</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >0.86</td></tr><tr><td align="center" valign="middle" >d<sub>4</sub>-5-HT</td><td align="center" valign="middle" >293.2</td><td align="center" valign="middle" >144.1</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >23</td><td align="center" valign="middle" >0.93</td></tr></tbody></table></table-wrap><p>described as follows: Q1 Mass (136.2 Da), Q3 Mass (119.2 Da), dwell time (50 msec), declustering potential (DP) (40 eV) and collision energy (CE) (12 eV) and retention time (1.49 min).</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Method Optimization</title><p>In this study, paraformaldehyde, benzaldehyde and butyraldehyde were investigated as derivatization reagents to react with DA, NE and 5-HT, respectively. Formaldehyde was reported as a common reagent to label amine groups [<xref ref-type="bibr" rid="scirp.85088-ref40">40</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref41">41</xref>] . Dimethylated products were hard to retain on the RP column and eluted quite early together with other interference (data not shown), probably due to their strong polarity. Derivatization with excess benzaldehyde resulted in additional peaks right before the target compounds which would interfere their quantification (data not shown). Dibutylated DA, NE and 5-HT had good retention on the RP column, and the peak shape of these compounds were also satisfied. Therefore, we finally chose butyraldehyde as the derivatization reagent to perform reductive amination with DA, NE and 5-HT in this study (<xref ref-type="fig" rid="fig1">Figure 1</xref>).</p><p>The temperature and the duration of derivatization were optimized in order to obtain high conversion yield. Conversion yield was defined by Equation. (1), where PA represented the peak-area of target analyte at certain time point under certain reaction condition and PA<sub>max</sub> was the highest peak-area could be obtained under the same condition.</p><p>Conversion yield ( % ) = P A P A max &#215; 100 % (1)</p><p>The conversion yields for all three MANTs increased with time, and the rates were faster at higher temperatures (<xref ref-type="fig" rid="fig2">Figure 2</xref>). The highest conversion yields achieved after fourteen hours incubation under room temperature (<xref ref-type="fig" rid="fig2">Figure 2</xref>(a)) and reached maximum after 140 - 200 min at 37˚C (<xref ref-type="fig" rid="fig2">Figure 2</xref>(b)). DA, NE and 5-HT could achieve highest conversion yields within 80, 40 and 80 min at 60˚C, respectively (<xref ref-type="fig" rid="fig2">Figure 2</xref>(c)). Finally, incubation of MANTs with butyraldehyde at 60˚C for 80 min was chosen as the reaction condition for derivatization. The</p><p>products were stable at 10˚C after 26 hours of storage in the UPLC autosampler (data not shown). Different volumes of the derivatized MANTs (6 - 10 μL) were injected into UPLC/MS/MS system to investigate the effect of injection volume on the detection of MANTs. The results showed that the optimal peak shape could be obtained when the injection volume was 6.5 μL. Lower injection volume would reduce the intensity of the signals, while higher injection volume would result in split peaks (data not shown).</p><p>In general, reductive amination of DA, NE and 5-HT with butyraldehyde at 60˚C for 80 min provided a simple way to convent MANTs into corresponding dibutylated derivatives with high conversion yield. The current method was simple and did not require complex sample preparation steps, such as synthesis of the derivatization reagents or an UA-DLIME procedure. The optimal chromatographic peak shape of the derivatized products could be obtained with the injection volume of 6.5 μL.</p></sec><sec id="s3_2"><title>3.2. Method Validation</title><p>The investigated linearity ranges of DA, NE and 5-HT were 25 - 5000, 5 - 1000 and 2.5 - 500 pg/mL, respectively. Good linearity correlations were obtained for the three MANTs with the coefficient of determination (R<sup>2</sup>) all above 0.99 (<xref ref-type="table" rid="table2">Table 2</xref>). The LODs (S/N &gt; 3) for DA, NE and 5-HT were 25, 5 and 2.50 pg/mL, respectively (<xref ref-type="table" rid="table2">Table 2</xref>). Chromatograms of derivatized DA and their corresponding internal standards were presented in <xref ref-type="fig" rid="fig3">Figure 3</xref>. It was reported that the basal levels of MANTs were around tens to thousands of pictograms per milliliter in rat brain microdialysate [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] . Therefore, the above results suggested that current method had adequate sensitivity for simultaneous determination of DA, NE and 5-HT in rat brain microdialysate. The intra-day coefficient of variance (CV, %) of six batches of QCs were all below 13.4%, 12.0% and 8.5% for DA, NE and 5-HT, suggesting good precision and reproducibility of the proposed method. Recovery of all three compounds at different concentrations were within &#177; 15% of spiked amount. All validation data suggested that present method was reliable and reproducible, and could be applied to accurate quantification of DA, NE and 5-HT in the aCSF matrix.</p></sec><sec id="s3_3"><title>3.3. Application of Proposed Method to Rat Brain Microdialysate</title><p>The developed method was applied to simultaneously monitor DA, NE and</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> The linearity range, LODs (limits of detection, S/N &gt; 3), R<sup>2</sup> (coefficient of determination), precision (coefficient of variation, CV, %) and accuracy (recovery, %) of the current method. Both the precision and the accuracy were obtained from the analytical results of six batches of QCs</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Analyte</th><th align="center" valign="middle" >Linearity Range (pg/mL)</th><th align="center" valign="middle" >LODs (pg/mL)</th><th align="center" valign="middle" >R<sup>2</sup></th><th align="center" valign="middle" >Spiked amount (pg/mL)</th><th align="center" valign="middle" >Precision (CV, %)</th><th align="center" valign="middle" >Accuracy (recovery %, mean &#177; SD)</th></tr></thead><tr><td align="center" valign="middle"  rowspan="4"  >DA</td><td align="center" valign="middle"  rowspan="4"  >25 - 5000</td><td align="center" valign="middle"  rowspan="4"  >25</td><td align="center" valign="middle"  rowspan="4"  >0.9960</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >13.4</td><td align="center" valign="middle" >103.3 &#177; 13.9</td></tr><tr><td align="center" valign="middle" >75</td><td align="center" valign="middle" >6.4</td><td align="center" valign="middle" >95.1 &#177; 6.1</td></tr><tr><td align="center" valign="middle" >400</td><td align="center" valign="middle" >2.0</td><td align="center" valign="middle" >100.0 &#177; 2.0</td></tr><tr><td align="center" valign="middle" >4000</td><td align="center" valign="middle" >2.0</td><td align="center" valign="middle" >104.5 &#177; 2.0</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >NE</td><td align="center" valign="middle"  rowspan="4"  >5 - 1000</td><td align="center" valign="middle"  rowspan="4"  >5</td><td align="center" valign="middle"  rowspan="4"  >0.9966</td><td align="center" valign="middle" >5</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" >102.8 &#177; 12.4</td></tr><tr><td align="center" valign="middle" >15</td><td align="center" valign="middle" >10.1</td><td align="center" valign="middle" >88.9 &#177; 9.0</td></tr><tr><td align="center" valign="middle" >80</td><td align="center" valign="middle" >4.5</td><td align="center" valign="middle" >97.4 &#177; 4.4</td></tr><tr><td align="center" valign="middle" >800</td><td align="center" valign="middle" >2.6</td><td align="center" valign="middle" >94.1 &#177; 2.5</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >5-HT</td><td align="center" valign="middle"  rowspan="4"  >2.5 - 500</td><td align="center" valign="middle"  rowspan="4"  >2.5</td><td align="center" valign="middle"  rowspan="4"  >0.9928</td><td align="center" valign="middle" >2.5</td><td align="center" valign="middle" >8.5</td><td align="center" valign="middle" >95.5 &#177; 8.1</td></tr><tr><td align="center" valign="middle" >7.5</td><td align="center" valign="middle" >5.8</td><td align="center" valign="middle" >102.6 &#177; 5.9</td></tr><tr><td align="center" valign="middle" >40</td><td align="center" valign="middle" >8.3</td><td align="center" valign="middle" >106.8 &#177; 8.9</td></tr><tr><td align="center" valign="middle" >400</td><td align="center" valign="middle" >5.2</td><td align="center" valign="middle" >101.8 &#177; 5.3</td></tr></tbody></table></table-wrap><p>5-HT in SD rat brain microdialysates for a course of 220 min (<xref ref-type="fig" rid="fig4">Figure 4</xref>). Thirty μL of the microdialysate was collected at each time point, and only 10 μL was used for derivatization. Three consecutive microdialysates were collected before intraperitoneal injection of AMPH to monitor basal levels of MANTs. The basal concentration of DA (<xref ref-type="fig" rid="fig4">Figure 4</xref>(b)), NE (<xref ref-type="fig" rid="fig4">Figure 4</xref>(c)), and 5-HT (<xref ref-type="fig" rid="fig4">Figure 4</xref>(d)) were in the ranges of 143-159 pg/mL, 5.0-7.4 pg/mL and 14.7-25.0 pg/mL, respectively. Significant concentration increase was observed for all MANTs after AMPH administration. DA (<xref ref-type="fig" rid="fig4">Figure 4</xref>(b)), NE (<xref ref-type="fig" rid="fig4">Figure 4</xref>(c)) and 5-HT (<xref ref-type="fig" rid="fig4">Figure 4</xref>(d)) reached highest concentration after 40 min, 40 min, and 60 min injection of AMPH, respectively, and subsequently decreased with time.</p></sec></sec><sec id="s4"><title>4. Discussion</title>Comparison with Previous Studies<p>This study presented a dibutylation derivatization coupled with a rapid UPLC-MS/MS (2.1 min/sample) to simultaneous determination of DA, NE and 5-HT. The acceptable precision (8.5% - 13.4%, CV) and accuracy (recovery, 94.1% - 106.8%) demonstrated the reliable and reproducibility of the current method. The derivatization procedure was simple and easy to handle without any extra steps, such as synthesis of derivatization reagent in advance [<xref ref-type="bibr" rid="scirp.85088-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>]</p><p>[<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] or an UA-DLIME procedure after derivatization [<xref ref-type="bibr" rid="scirp.85088-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] . Direct measurement of DA, NE and 5-HT without chemical derivatization resulted in poor sensitivity, which was not sensitive enough to evaluate the basal levels of MANTs in rat brain microdialysate [<xref ref-type="bibr" rid="scirp.85088-ref21">21</xref>] ; or such method could only analyze DA, and required LC separation time as long as 30 min [<xref ref-type="bibr" rid="scirp.85088-ref22">22</xref>] . The LODs of NE and 5-HT after derivatization with benzoyl chloride were relatively high (~34 pg/mL and 18 pg/mL, respectively), and UPLC-MS/MS run time was four time longer than current study [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] . In our own effort to reproduce this method, very high background noise was observed (data not shown). Diethyl reductive amination approach offered adequate sensitivity (5 - 10 pg/mL) and shorter analysis time (3.5 min/sample) [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] , however, the results were difficult to reproduce when the same procedure was tried in author’s lab. Sensitivity was higher if MANTs were derivatizied with LRSC or d<sub>0</sub>-MASC (&lt;0.1 pg/mL), however, both methods needed relatively long analytical run time (7 min and 5 min, respectively) and d<sub>0</sub>-MASC needed to be synthesized in advance [<xref ref-type="bibr" rid="scirp.85088-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref18">18</xref>] . Although our method did not provide the lowest LODs, it was adequate to quantify basal levels of the three MANTs in the rat brain microdialysate (tens to thousands of pictograms per milliliter) [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] . Last but not least, butyraldehyde was more environmental friendly reagent compared with acyl chloride and sulfonyl chloride.</p><p>Low perfusion rate was a guarantee of an analyte’s recovery in vivo, but resulted in small sample volume or poor temporal resolution [<xref ref-type="bibr" rid="scirp.85088-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref14">14</xref>] . Quantification of low basal level of MANTs with a small volume of microdialysate became a big challenge for the bioanalysts. In most previous studies, more than twenty μL of the microdialysate were utilized for derivatization or direct analysis by the instruments [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] . If the requirement of sample volume was reduced, better temporal resolution could be obtained [<xref ref-type="bibr" rid="scirp.85088-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref14">14</xref>] and the rest portion of the sample could be reserved for the future reanalysis. In present study, one third of the collected microdialysate (10 μL out of 30 μL) was applied for derivatization which was smaller than most of the previous studies [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] . Song et al., provided a method using 5 μl of microdialysate [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] for derivatization, but their LODs of NE and 5-HT were relatively high (~34 pg/mL and 18 pg/mL) compared with current method.</p><p>Short chromatography run-time was another important evaluation criterion for a good bioanalytical method, which was an important consideration for improving efficiency of a lab. The UPLC-MS/MS run time of present study was 2.1 min/sample, which was the shortest compared with previous studies (~3.5 min~30 min) [<xref ref-type="bibr" rid="scirp.85088-ref15">15</xref>] - [<xref ref-type="bibr" rid="scirp.85088-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref28">28</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref39">39</xref>] . The derivatized MANTs all eluted between 0.7 min and 1.0 min, and only this portion of the LC eluent was directly flew into the mass spectrometer, while the LC eluent at other time was went to waste. Current method could be easily adapted to a dual-arm high-throughput autosampler (Apricot Design Dual Arm, ADDA) coupled with LC-MS/MS technique system [<xref ref-type="bibr" rid="scirp.85088-ref45">45</xref>] [<xref ref-type="bibr" rid="scirp.85088-ref46">46</xref>] . While operated under gradient mode, two liquid chromatography systems could be incorporated into one, while one LC system performed analyte separation and the other LC system executed functions such as needle washing, column equilibration and sample injection. A switch valve determined the eluent of which LC system went into the mass spectrometer for data acquisition. If current method would be successfully transferred to ADDA-LC-MS/MS platform, the chromatography run time could be further shorten to half and the efficiency would be double in the future.</p></sec><sec id="s5"><title>5. Conclusion</title><p>In this work, a simple dibutylation derivatization method coupled with a rapid UPLC-MS/MS was developed for the simultaneous determination of DA, NE and 5-HT. Derivatization was easy to handle, which was performed with butyraldehyde and sodium cyanoborohydride in 60˚C water bath for 80 min incubation. A rapid 2.1 min UPLC-MS/MS protocol was established, which was shorter than previous studies. This method was successfully applied to detect the basal and elevated levels of DA, NE and 5-HT with a small volume of rat brain microdialysate (10 μL). Acceptable validation results suggested that this method was reliable and reproducible. Present study provided a solid foundation for the future development of MANT analysis in the body fluids.</p></sec><sec id="s6"><title>Acknowledgements</title><p>We thank Pharmacokinetics and Pharmacodynamics Group (PK-PD Group) in Drug Metabolism and Pharmacokinetics (DMPK) unit of Lab-Testing Division (LTD) in WuXi AppTec Co., Ltd. for providing in vivo rat brain microdialysis samples, International Discovery Service Unit (IDSU) of Research Service Division (RSD) in WuXi AppTec Co., Ltd. for derivatization agents screening. This project was financially support by DMPK unit of LTD in WuXi AppTec Co., Ltd.</p></sec><sec id="s7"><title>Cite this paper</title><p>Lu, J.L., Hu, W.M., Cao, W.Q., Xie, S.T., Li, Z.Y., Tao, Y. and Zhang, X. (2018) Rapid and Reproducible Dibutylation Derivatization Coupled with Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry for the Simultaneous Determination of Dopamine, Norepinephrine and 5-Hydroxytryp- tamine in Rat Brain Microdialysates. International Journal of Analytical Mass Spectrometry and Chromatography, 6, 21-36. https://doi.org/10.4236/ijamsc.2018.62002</p></sec></body><back><ref-list><title>References</title><ref id="scirp.85088-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Kurian, M.A., Gissen, P., Smith, M., Heales, S.J. and Clayton, P.T. (2011) The Mono-amine Neurotransmitter Disorders: An Expanding Range of Neurological Syndromes. The Lancet Neurology, 10, 721-733.  
&lt;br&gt;https://doi.org/10.1016/S1474-4422(11)70141-7</mixed-citation></ref><ref id="scirp.85088-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Winberg, S. and Nilsson, G.E. (1993) Roles of Brain Monoamine Neurotransmitters in Agonistic Behaviour and Stress Reactions, with Particular Reference to Fish. Comparative Bio-chemistry and Physiology. Part C: Toxicology &amp; Pharmacology, 106, 597-614. &lt;br&gt;https://doi.org/10.1016/0742-8413(93)90216-8</mixed-citation></ref><ref id="scirp.85088-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Lovheim, H. (2012) A New Three-Dimensional Model for Emotions and Monoamine Neurotransmitters. Medical Hypothese, 78, 341-348.  
&lt;br&gt;https://doi.org/10.1016/j.mehy.2011.11.016</mixed-citation></ref><ref id="scirp.85088-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Lesch, K. (2007) Linking Emotion to the Social Brain. EMBO Reports, 8, S24-S29.  
&lt;br&gt;https://doi.org/10.1038/sj.embor.7401008</mixed-citation></ref><ref id="scirp.85088-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Lai, M., McCormick, J., Chapman, K., Kelly, P., Seckl, J. and Yau, J. (2003) Differential Regulation of Cortico-steroid Receptors by Monoamine Neurotransmitters and Antidepressant Drugs in Primary Hippocampal Culture. Neuroscience, 118, 975-984.  
&lt;br&gt;https://doi.org/10.1016/S0306-4522(03)00038-1</mixed-citation></ref><ref id="scirp.85088-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Anisman, H., Merali, Z. and Hayley, S. (2008) Neurotransmitter, Peptide and Cytokine Processes in Relation to Depressive Disorder: Comorbidity between Depression and Neurodegenerative Disorders. Progress in Neurobiology, 85, 1-74.  
&lt;br&gt;https://doi.org/10.1016/j.pneurobio.2008.01.004</mixed-citation></ref><ref id="scirp.85088-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Ho, S., Kapadi, A., Ramsden, D. and Williams, A. (1995) An Allelic Association Study of Monoamine Oxidase B in Parkinson’s Disease. Annals of Neurology, 37, 403-405. &lt;br&gt;https://doi.org/10.1002/ana.410370318</mixed-citation></ref><ref id="scirp.85088-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Ellison, D., Beal, M., Mazurek, M., Malloy, J., Bird, E. and Martin, J. (1987) Amino Acid Neurotransmitter Abnormal-ities in Huntington’s Disease and the Quinolinic Acid Animal Model of Huntington’s Disease. Brain, 110, 1657-1673.  
&lt;br&gt;https://doi.org/10.1093/brain/110.6.1657</mixed-citation></ref><ref id="scirp.85088-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Mann, D., Yates, P. and Marcyniuk, B. (1987) Dopaminergic Neurotransmitter Systems in Alzheimer’s Disease and in Down’s Syndrome at Middle Age. Journal of Neurology, Neurosurgery and Psychiatry, 50, 341-344.  
&lt;br&gt;https://doi.org/10.1136/jnnp.50.3.341</mixed-citation></ref><ref id="scirp.85088-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Mann, D.M. (1988) The Pathological Association between Down Syndrome and Alzheimer Disease. Mechanisms of Ageing and Development, 43, 99-136.  
&lt;br&gt;https://doi.org/10.1016/0047-6374(88)90041-3</mixed-citation></ref><ref id="scirp.85088-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Nazarali, A.J. and Reynolds, G.P. (1992) Monoamine Neurotransmitters and Their Metabolites in Brain Regions in Alzheimer’s Disease: A Postmortem Study. Cellular and Molecular Neuro-biology, 12, 581-587. &lt;br&gt;https://doi.org/10.1007/BF00711237</mixed-citation></ref><ref id="scirp.85088-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Ng, J., Papandreou, A., Heales, S.J. and Kurian, M.A. (2015) Monoamine Neurotransmitter Disorders—Clinical Advances and Future Perspectives. Nature Reviews. Neurology, 11, 567. &lt;br&gt;https://doi.org/10.1038/nrneurol.2015.172</mixed-citation></ref><ref id="scirp.85088-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Chefer, V.I., Thompson, A.C., Zapata, A. and Shippenberg, T.S. (2009) Overview of Brain Microdi-alysis. Current Protocols in Neuroscience.  
&lt;br&gt;https://doi.org/10.1002/0471142301.ns0701s47</mixed-citation></ref><ref id="scirp.85088-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Plock, N. and Kloft, C. (2005) Microdialysis—Theoretical Background and Recent Implementation in Applied Life-Sciences. European Journal of Pharmaceutical Sciences, 25, 1-24. &lt;br&gt;https://doi.org/10.1016/j.ejps.2005.01.017</mixed-citation></ref><ref id="scirp.85088-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Ji, C., Li, W., Ren, X., El-Kattan, A.F., Kozak, R., Fountain, S. and Lepsy, C. (2008) Diethylation Labeling Combined with UPLC/MS/MS for Simultaneous Determination of a Panel of Monoamine Neurotransmitters in Rat Prefrontal Cortex Microdialysates. Analytical Chemistry, 80, 9195-9203. &lt;br&gt;https://doi.org/10.1021/ac801339z</mixed-citation></ref><ref id="scirp.85088-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Zhao, X.-E., He, Y., Yan, P., Wei, N., Wang, R., Sun, J., Zheng, L., Zhu, S. and You, J. (2016) Sensitive and Accurate Determination of Neurotransmitters from in Vivo Rat Brain Microdialysate of Parkinson’s Disease Using in Situ Ultrasound-Assisted Derivatization Dispersive Liquid-Liquid Microextraction by UHPLC-MS/MS. RSC Advances, 6, 108635-108644. &lt;br&gt;https://doi.org/10.1039/C6RA23808D</mixed-citation></ref><ref id="scirp.85088-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Wei, N., Zhao, X.-E., Zhu, S., He, Y., Zheng, L., Chen, G., You, J., Liu, S. and Liu, Z. (2016) Determination of Dopamine, Serotonin, Biosynthesis Precursors and Metabolites in Rat Brain Microdialysates by Ultrasonic-Assisted in Situ Derivatization-Dispersive Liquid-Liquid Microextraction Coupled with UHPLC-MS/MS. Talanta, 161, 253-264. &lt;br&gt;https://doi.org/10.1016/j.talanta.2016.08.036</mixed-citation></ref><ref id="scirp.85088-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Zheng, L., Zhao, X.-E., Zhu, S., Tao, Y., Ji, W., Geng, Y., Wang, X., Chen, G. and You, J. (2017) A New Combined Method of Stable Isotope-Labeling Derivatization-Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction for the Determination of Neurotransmitters in Rat Brain Microdialysates by Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry. Journal of Chromatography B, 1054, 64-72. &lt;br&gt;https://doi.org/10.1016/j.jchromb.2017.03.039</mixed-citation></ref><ref id="scirp.85088-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, L.-H., Cai, H.-L., Jiang, P., Cao, L.-J., Dang, R.-L., Zhu, W.-Y. and Deng, Y. (2015) Simultaneous Determination of Multiple Neurotransmitters and Their Metabolites in Rat Brain Homogenates and Microdialysates by LC-MS/MS. Analytical Methods, 7, 3929-3938. &lt;br&gt;https://doi.org/10.1039/C5AY00308C</mixed-citation></ref><ref id="scirp.85088-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">He, Y., Zhao, X.-E., Zhu, S., Wei, N., Sun, J., Zhou, Y., Liu, S., Liu, Z., Chen, G. and Suo, Y. (2016) In Situ Derivatization-Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction for the Determination of Neurotransmitters in Parkinson’s Rat Brain Microdialysates by Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry. Journal of Chromatography A, 1458, 70-81. 
&lt;br&gt;https://doi.org/10.1016/j.chroma.2016.06.059</mixed-citation></ref><ref id="scirp.85088-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Hows, M.E., Lacroix, L., Heidbreder, C., Organ, A.J. and Shah, A.J. (2004) High-Performance Liquid Chromatography/Tandem Mass Spectrometric Assay for the Simultaneous Measurement of Dopamine, Norepinephrine, 5-Hydroxytryptamine and Cocaine in Biological Samples. Journal of Neuroscience Methods, 138, 123-132. &lt;br&gt;https://doi.org/10.1016/j.jneumeth.2004.03.021</mixed-citation></ref><ref id="scirp.85088-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Qi, D., Zhang, Q., Zhou, W., Zhao, J., Zhang, B., Sha, Y. and Pang, Z. (2016) Quantification of Dopamine in Brain Microdialysates with High-Performance Liquid Chromatography-Tandem Mass Spectrometry. Analytical Sciences, 32, 419-424.</mixed-citation></ref><ref id="scirp.85088-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Staiti, A.M., Morgane, P.J., Galler, J.R., Grivetti, J.Y., Bass, D.C. and Mokler, D.J. (2011) A Microdialysis Study of the Medial Prefrontal Cortex of Adolescent and Adult Rats. Neuropharmacology, 61, 544-549.  
&lt;br&gt;https://doi.org/10.1016/j.neuropharm.2011.04.005</mixed-citation></ref><ref id="scirp.85088-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Wong, J.-M.T., Malec, P.A., Mabrouk, O.S., Ro, J., Dus, M. and Kennedy, R.T. (2016) Benzoyl Chloride Derivatization with Liquid Chromatography-Mass Spectrometry for Targeted Metabolomics of Neurochemicals in Biological Samples. Journal of Chromatography A, 1446, 78-90.  
&lt;br&gt;https://doi.org/10.1016/j.chroma.2016.04.006</mixed-citation></ref><ref id="scirp.85088-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Nirogi, R., Komarneni, P., Kandikere, V., Boggavarapu, R., Bhyrapuneni, G., Benade, V. and Gorentla, S. (2013) A Sensitive and Selective Quantification of Catecholamine Neurotransmitters in Rat Microdialysates by Pre-Column Dansyl Chloride Derivatization Using Liquid Chromatography-Tandem Mass Spectrometry. Journal of Chromatography B, 913-914, 41-47.</mixed-citation></ref><ref id="scirp.85088-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Qi, W., Zhao, X., Qi, Y., Sun, Z., Chen, G., You, J. and Suo, Y. (2015) Determination of L-Dopa and Dopamine in Rat Brain Microdialysate by Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry Using Stable Isotope-Coded Derivatization Coupled with Dispersive Liquid-Liquid Microextraction. Chinese Journal of Chromatography, 33, 981-987.</mixed-citation></ref><ref id="scirp.85088-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Greco, S., Danysz, W., Zivkovic, A., Gross, R. and Stark, H. (2013) Microdialysate Analysis of Monoamine Neurotransmitters—A Versatile and Sensitive LC-MS/MS Method. Analytical Chimica Acta, 771, 65-72.  
&lt;br&gt;https://doi.org/10.1016/j.aca.2013.02.004</mixed-citation></ref><ref id="scirp.85088-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Song, P., Mabrouk, O.S., Hershey, N.D. and Kennedy, R.T. (2011) In Vivo Neurochemical Monitoring Using Benzoyl Chloride Derivatization and Liquid Chromatography-Mass Spectrometry. Analytical Chemistry, 84, 412-419. 
&lt;br&gt;https://doi.org/10.1021/ac202794q</mixed-citation></ref><ref id="scirp.85088-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Ganesana, M., Lee, S.T., Wang, Y. and Venton, B.J. (2016) Analytical Techniques in Neuroscience: Recent Advances in Imaging, Separation, and Electrochemical Methods. Analytical Chemistry, 89, 314-341.</mixed-citation></ref><ref id="scirp.85088-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Gonon, F., Buda, M., Cespuglio, R., Jouvet, M. and Pujol, J.-F. (1980) In Vivo Electrochemical Detection of Catechols in the Neostriatum of Anaesthetized Rats: Dopamine or DOPAC? Nature, 286, 902-904. &lt;br&gt;https://doi.org/10.1038/286902a0</mixed-citation></ref><ref id="scirp.85088-ref31"><label>31</label><mixed-citation publication-type="book" xlink:type="simple">Venn, R.F. (2000) 5.5.3. Electro-chemical Detectors. In: Venn, R.F., Ed., Principles and Practice of Bioanalysis, CRC Press, Boca Raton, 120-122.  
&lt;br&gt;https://doi.org/10.4324/9780203449479</mixed-citation></ref><ref id="scirp.85088-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Zhao, X.-E. and Suo, Y.-R. (2008) Simultaneous Determination of Monoamine and Amino Acid Neurotransmitters in Rat Endbrain Tissues by Pre-Column Derivatization with High-Performance Liquid Chromatographic Fluorescence Detection and Mass Spectrometric Identification. Talanta, 76, 690-697. 
&lt;br&gt;https://doi.org/10.1016/j.talanta.2008.04.032</mixed-citation></ref><ref id="scirp.85088-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Yoshitake, T., Kehr, J., Todoroki, K., Nohta, H. and Yamaguchi, M. (2006) Derivatization Chemistries for De-termination of Serotonin, Norepinephrine and Dopamine in Brain Microdialysis Samples by Liquid Chromatography with Fluorescence Detection. Biomedical Chromatography, 20, 267-281.  
&lt;br&gt;https://doi.org/10.1002/bmc.560</mixed-citation></ref><ref id="scirp.85088-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Yoshitake, T., Fujino, K., Kehr, J., Ishida, J., Nohta, H. and Yamaguchi, M. (2003) Simultaneous Determination of Nore-pinephrine, Serotonin, and 5-Hydroxyindole-3-Acetic Acid in Microdialysis Samples from Rat Brain by Microbore Column Liquid Chromatography with Fluorescence Detection Following Derivatization with Benzylamine. Analytical Biochemistry, 312, 125-133.  
&lt;br&gt;https://doi.org/10.1016/S0003-2697(02)00435-9</mixed-citation></ref><ref id="scirp.85088-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Yoshitake, T., Kehr, J., Yoshitake, S., Fujino, K., Nohta, H. and Yamaguchi, M. (2004) Determination of Serotonin, Noradrenaline, Dopamine and Their Metabolites in Rat Brain Extracts and Microdialysis Samples by Column Liquid Chromatography with Fluorescence Detection Following Derivatization with Benzylamine and 1,2-Diphenylethylenediamine. Journal of Chromatography B, 807, 177-183. 
&lt;br&gt;https://doi.org/10.1016/j.jchromb.2004.03.069</mixed-citation></ref><ref id="scirp.85088-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Wu, D., Xie, H., Lu, H., Li, W. and Zhang, Q. (2016) Sensitive Determination of Norepinephrine, Epinephrine, Dopamine and 5-Hydroxytryptamine by Coupling HPLC with [Ag(HIO6)2]5--Luminol Chemiluminescence Detection. Biomedical Chromatography, 30, 1458-1466. &lt;br&gt;https://doi.org/10.1002/bmc.3704</mixed-citation></ref><ref id="scirp.85088-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Jung, M.C., Shi, G., Borland, L., Michael, A.C. and Weber, S.G. (2006) Simultaneous Determination of Biogenic Monoamines in Rat Brain Dialysates Using Capillary High-Performance Liquid Chromatography with Photoluminescence Following Electron Transfer. Analytical Chemistry, 78, 1755-1760.  
&lt;br&gt;https://doi.org/10.1021/ac051183g</mixed-citation></ref><ref id="scirp.85088-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Li, N., Guo, J., Liu, B., Yu, Y., Cui, H., Mao, L. and Lin, Y. (2009) Determination of Monoamine Neurotransmitters and Their Metabolites in a Mouse Brain Microdialysate by Coupling High-Performance Liquid Chromatography with Gold Nanoparticle-Initiated Chemiluminescence. Analytical Chimca Acta, 645, 48-55. 
&lt;br&gt;https://doi.org/10.1016/j.aca.2009.04.050</mixed-citation></ref><ref id="scirp.85088-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Zhao, X.-E., He, Y., Li, M., Chen, G., Wei, N., Wang, X., Sun, J., Zhu, S. and You, J. (2017) Analysis of Amino Acid and Monoamine Neurotransmitters and Their Metabolites in Rat Urine of Alzheimer’s Disease Using in Situ Ultrasound-Assisted Derivatization Dispersive Liquid-Liquid Microextraction with UHPLC-MS/MS. Journal of Pharmaceutical and Biomedical Analysis, 135, 186-198. 
&lt;br&gt;https://doi.org/10.1016/j.jpba.2016.11.056</mixed-citation></ref><ref id="scirp.85088-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Hsu, J.-L., Huang, S.-Y., Chow, N.-H. and Chen, S.-H. (2003) Stable-Isotope Dimethyl Labeling for Quantitative Proteomics. Analytical Chemistry, 75, 6843-6852. 
&lt;br&gt;https://doi.org/10.1021/ac0348625</mixed-citation></ref><ref id="scirp.85088-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Guo, K., Ji, C. and Li, L. (2007) Sta-ble-Isotope Dimethylation Labeling Combined with LC-ESI MS for Quantification of Amine-Containing Metabolites in Biological Samples. Analytical Chemistry, 79, 8631-8638. &lt;br&gt;https://doi.org/10.1021/ac0704356</mixed-citation></ref><ref id="scirp.85088-ref42"><label>42</label><mixed-citation publication-type="other" xlink:type="simple">Jemal, M. (2000) High-Throughput Quantitative Bioanalysis by LC/MS/MS. Biomedical Chromatog-raphy, 14, 422-429. 
&lt;br&gt;https://doi.org/10.1002/1099-0801(200010)14:6&lt;422::AID-BMC25&gt;3.0.CO;2-I</mixed-citation></ref><ref id="scirp.85088-ref43"><label>43</label><mixed-citation publication-type="other" xlink:type="simple">Xu, R.N., Fan, L., Rieser, M.J. and El-Shourbagy, T.A. (2007) Recent Advances in High-Throughput Quantitative Bioanalysis by LC-MS/MS. Journal of Pharmaceutical and Biomedical Analysis, 44, 342-355.  
&lt;br&gt;https://doi.org/10.1016/j.jpba.2007.02.006</mixed-citation></ref><ref id="scirp.85088-ref44"><label>44</label><mixed-citation publication-type="other" xlink:type="simple">Yang, W.-C., Mirzaei, H., Liu, X. and Regnier, F.E. (2006) Enhancement of Amino Acid Detection and Quantification by Electrospray Ionization Mass Spectrometry. Analytical Chemistry, 78, 4702-4708. &lt;br&gt;https://doi.org/10.1021/ac0600510</mixed-citation></ref><ref id="scirp.85088-ref45"><label>45</label><mixed-citation publication-type="other" xlink:type="simple">Li, X., Su, Y., Zhu, C., Tao, Y., Fang, X. and Zhang, X. (2016) Data Robustness of a High-Throughput Autosampler (Apricot Design Dual Arm-ADDA) in Discovery ADME Sample Analysis. ASMS Conference on Mass Spectrometry, San Antonio, TX.</mixed-citation></ref><ref id="scirp.85088-ref46"><label>46</label><mixed-citation publication-type="other" xlink:type="simple">Fu, X., Wang, H., Li, X., Su, Y., Tao, Y. and Zhang, X. (2017) High-Throughput Determination of Kynurenine in IDO Assay by LC-MS/MS. ASMS Conference on Mass Spectrometry, Indianapolis, IN.</mixed-citation></ref></ref-list></back></article>