<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SGRE</journal-id><journal-title-group><journal-title>Smart Grid and Renewable Energy</journal-title></journal-title-group><issn pub-type="epub">2151-481X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/sgre.2018.91001</article-id><article-id pub-id-type="publisher-id">SGRE-81768</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Earth&amp;Environmental Sciences</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Experimental Study of the Cloud Influence on PV Grid Connected System
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yassir</surname><given-names>Idris Abdalla Osman</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jinping</surname><given-names>Li</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xiaofei</surname><given-names>Zhen</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Airong</surname><given-names>Yang</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff3"><addr-line>China Northwestern Collaborative Innovation Center of Key Technology for Northwest Low Carbon Urbanization, Lanzhou, China</addr-line></aff><aff id="aff2"><addr-line>Gansu Key Laboratory of Complementary Energy System of Biomass and Solar Energy, Lanzhou, China</addr-line></aff><aff id="aff1"><addr-line>Western China Energy &amp;amp; Environment Research Center, Lanzhou University of Technology, Lanzhou, China</addr-line></aff><pub-date pub-type="epub"><day>16</day><month>01</month><year>2018</year></pub-date><volume>09</volume><issue>01</issue><fpage>1</fpage><lpage>15</lpage><history><date date-type="received"><day>27,</day>	<month>November</month>	<year>2017</year></date><date date-type="rev-recd"><day>13,</day>	<month>January</month>	<year>2018</year>	</date><date date-type="accepted"><day>16,</day>	<month>January</month>	<year>2018</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In recent years, PV panels witnessed a vigorous gross, as their performance and the leverage of large-scale industrial production steadily decreased costs. Factors such as solar irradiance, insolation, mismatch of modules/arrays characteristic, aging, partial shading situation have a major effect on the harvested power. Evidence suggests that partial shading situation is the most critical factor and causes a significant reduction in PV system output. In this paper, a method based on two degrees of freedom, namely upper and lower was proposed in order to address the partial shading losses that due to cloud movement. Moreover, an extensive simulation of voltage, current indicators, bypassed modules, fault string, and DC output power was presented to analyze the PV system. The validation of experimental data analysis was carried out on two different days with different amounts of solar irradiance in Minqin County, Gansu Province, China. The results indicated that the power losses were 18.989 W and 127.629 W according to the minimum and the maximum irradiations (1.88 MW/m
  <sup>2</sup>) and (2.104 MW/m
  <sup>2</sup>) respectively. By considering the minimum irradiance, the upper and the lower degrees of freedom of the losses were 22.17 W/d, and 15.8 W/d respectively. On the other hand, by considering the maximum irradiance, the upper and the lower degrees of freedom were 130.49 W/d, 125.78 W/d respectively.
 
</p></abstract><kwd-group><kwd>Photovoltaic Systems</kwd><kwd> Partial Shading</kwd><kwd> Current and Voltage Indicators</kwd><kwd> Degree of Freedom</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Recently, there was a large volume of published studies describing Photovoltaic (PV) array as an essential renewable energy source, obviously, due to the significant penetration of PV sources in electricity generation [<xref ref-type="bibr" rid="scirp.81768-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref2">2</xref>] . It was generally considered that partial shading (PS) may seriously affect the characteristic curve of the PV arrays [<xref ref-type="bibr" rid="scirp.81768-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref5">5</xref>] . The presence of bypassing diodes provides an alternate path for the current, thus the amount of cell’s current of the module is greatly different under PS conditions. Therefore, the PV characteristic curve shows multiple maximum points.</p><p>In order to overcome PS effects, a number of techniques have been considered, such as the connection of bypass diodes in anti-parallel to PV cells/ modules. In case, reverse bias occurs to any solar cell/module, this module is bypassed and the full current passes through the bypass diode and thus avoids module damage. Clearly, the integration of bypass diodes into photovoltaic arrays is economically costly. Furthermore, extra losses are detected across these diodes under PS conditions. These losses have a major effect in case of low-vol- tage applications. Commonly, the non-linearity of PV characteristic and bypass diodes together are causing a significant issue under PS condition, mainly, the existence of multiple maxima. In order to overcome this issue, a considerable amount of literature has been published on finding GMPP out of all local MPP [<xref ref-type="bibr" rid="scirp.81768-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref8">8</xref>] . These publications concentrate on track speed, number and types of sensors required, accuracy, cost, hardware requirements, complexity, etc. On the other hand, techniques based on micro-converters are adopted to deal with PS losses [<xref ref-type="bibr" rid="scirp.81768-ref9">9</xref>] , other approaches utilize adaptive reconfiguration for connecting PV modules [<xref ref-type="bibr" rid="scirp.81768-ref10">10</xref>] - [<xref ref-type="bibr" rid="scirp.81768-ref15">15</xref>] , AC modules [<xref ref-type="bibr" rid="scirp.81768-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref18">18</xref>] , recovery of energy [<xref ref-type="bibr" rid="scirp.81768-ref19">19</xref>] . The major disadvantage of these approaches is the higher cost since, each module works at its MPP. A technique based on sudoku puzzle pattern, magic square pattern, and futoshiki puzzle pattern is adopted for reposition of modules which are reported in [<xref ref-type="bibr" rid="scirp.81768-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref23">23</xref>] . Mainly, these techniques depend on the shadow pattern to locate the modules in the optimal position in order to minimize the losses. However, these approaches are commonly associated with square PV arrays; moreover, the line losses are increased as a result of increasing the length of interconnections. Generally, mismatch losses are a direct result of moving cloud shadows. Moreover, factors such as electrical configuration, PV array shape, and geographic orientation are also influenced mismatch losses [<xref ref-type="bibr" rid="scirp.81768-ref24">24</xref>] . The approach of determining the time window of shadows based on measured data was provided in [<xref ref-type="bibr" rid="scirp.81768-ref25">25</xref>] , where an average of around 13 m/s was found as a variant of the shadow’s speed.</p><p>Although there are many reports in the literature on the PV performance and output power, most are restricted to overpassing cloud shadows and their effects, irradiance characteristics and mathematical modeling of irradiance as in [<xref ref-type="bibr" rid="scirp.81768-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref28">28</xref>] .</p><p>This paper presents a method based on the degree of freedom (DOF) to address the calculation of partial shading losses that due to cloud movement over the photovoltaic surface. The measured data of two different winter days with different amounts of irradiance were analyzed. Voltage and current indicators in addition to mathematical model presented in [<xref ref-type="bibr" rid="scirp.81768-ref29">29</xref>] are considered to detect the faults of PV. An extensive simulation of voltage and current indicators, bypassed modules, fault string, and DC output power was presented. Furthermore, two degrees of freedom are considered, namely upper and lower limit to address the shadow movement over the PV surface. Clearly, the most critical stage of using DOF method, emphasized that the amount of the losses has been revealed based on the measured irradiance of the two different winter days. The DC power losses (upper and lower limit), Average power generation, percentage of generation reduction, system consumption [<xref ref-type="bibr" rid="scirp.81768-ref30">30</xref>] , and percentage reduction of system consumption is calculated. However, the analyzation provided in this paper based directly on measured data associated with a specific location, the outcomes are not regionally bounded.</p></sec><sec id="s2"><title>2. Methodology</title>Fault Detection Parameters<p>In order to detect faults in PV arrays and realize full automatic supervision indicators for current and voltage are considered and denoted as N R c and N R v respectively [<xref ref-type="bibr" rid="scirp.81768-ref29">29</xref>] .</p><p>N R c = I m I s c (1)</p><p>N R v = V m V o c (2)</p><p>I m and V m are the current and voltage of MPP, these parameters can be calculated at the inverter input.</p><p>V o c and I s c denote the open circuit voltage and short circuit current respectively, these values are related to the inverter and describe the status of irradiance and temperature in real time. In the light of this, it is necessary for the inverter to have the advantage of monitoring. Within the same context, under normal operation condition V m o and I m o are the voltage and current of the PV array at the maximum power point. Furthermore, in the absence of fault the expected values of N R c and N R v are:</p><p>N R c o = I m o I s c (3)</p><p>N R v o = V m o V o c (4)</p><p>In order to detect the open circuit and short circuit the thresholds for current and voltage T N R c f s and T N R v b m .</p><p>Respectively must be defined as follows:</p><p>T N R c f s = 1.02 α N R c o (5)</p><p>T N R v b m = 1.02 β R v o (6)</p><p>where α and β denote the relationship between the ratio of current in case of one fault string and fault-free operation, and the ratio between the voltage ration in the case of one PV module was bypassed and fault-free operation respectively provided by Equations (7) and (8). Further, in order to avoid detection of the false fault the constant in the Equations (5) and (6) must be included, this constant represent an offset of a 2% respect the expected value of the current indicator N R c o .</p><p>α = N R c f s N R c o = 1 − 1 N p (7)</p><p>β = N R v b m N R v o = 1 − 1 N s (8)</p><p>When the PV array was totally damaged the corresponding voltage and current for open circuits or short circuit indicators mostly remain under its threshold.</p><p>Partial shading of PV arrays inevitably reduced the amount of the power output [<xref ref-type="bibr" rid="scirp.81768-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref31">31</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref32">32</xref>] . However, partial shading was characterized by dynamic evolution of the cloud, in addition to natural obstacle [<xref ref-type="bibr" rid="scirp.81768-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.81768-ref33">33</xref>] .</p><p>According to the number of shaded PV modules and the amount of shadow the total output current is reduced. On the other hand, the number of activated bypass diodes in the PV module affected directly the overall output voltage [<xref ref-type="bibr" rid="scirp.81768-ref34">34</xref>] . Monitoring process for current and voltage degradation can be achieved simultaneously or separately according to the shadow pattern and PV array alignment. Furthermore, the appearance of these effects is instantaneous due to the irradiance dynamic behavior except in case the PV module totally impaired. Accordingly, current and voltage are particularly useful in this context. Degradation in output voltage is given by:</p><p>Δ V = ( V m o − V m V m o ) ( 1 − N R v N R v o ) (9)</p><p>Assuming N s is a number of PV modules in serious, PV modules bypassed numbers, BPmod, due to shadow influence are calculated by:</p><p>B P m o d = Δ V N s (10)</p><p>The variation of degradation in the current output Δ I is given by:</p><p>Δ I = ( I m o − I m I m o ) ( 1 − N R c N R c o ) (11)</p><p>In case the PV array are connected in parallel, the losses in output current are expressed in term of the number of equivalent faulty strings in open circuit E F s as:</p><p>E F s = Δ I N p (12)</p><p>Accordingly, by considering current and voltage indicators the partial shadow on the PV can be detected even if their values are below the thresholds of each. The number of bypassing modules and the equivalent number of faulty strings can be calculated using Equations (10) and (12) respectively in the presence of partial shadow. From Equations (9) and (11), the losses due the shadowing effect in the DC power are given by:</p><p>P losses = ( 1 − N R c N R c o N R v N R v o ) (13)</p><p>Estimation of the principal parameters associated with the equations play a major role in the accuracy of this method particularly I s c , V o v , I m o , V m o , I m , and V m .</p><p>The ability of the inverter to track the maximum power point affects the assessments of V m and I m . It should be mentioned that the values of N R c o , N R v o , T N R c f s and T N R v b m are completely independent of MPP real values. In case the inverter stuck at local maxima, parameters such as N R c and N R v are lower than the real values of MPP. Clearly, the algorithm will be capable of detecting the amount of power losses, which is the difference between the actual MPP and MPP local value.</p></sec><sec id="s3"><title>3. Degree of Freedom</title><p>The movement of the shadow over the PV surface is addressed in <xref ref-type="fig" rid="fig1">Figure 1</xref>, considering the degree of freedom technique (upper and lower limit) to define the shadow movement (red arrows). <xref ref-type="fig" rid="fig1">Figure 1</xref>(a) describes the upper limit case, where the shadow edges are located over the PV surface, on the other hand, <xref ref-type="fig" rid="fig1">Figure 1</xref>(b) shows the lower limit case, where a part of the shadow is situated over the PV surface. Based on the degree of freedom technique, the output of the system was analyzed and the results were presented.</p></sec><sec id="s4"><title>4. Experiment Setup</title><p>Partial shading grid connecting PV system phenomenon was analyzed considering the evolution of current and voltage indicators. The PV system was a part of a project designed and tested in a single building in a MinQing China [<xref ref-type="bibr" rid="scirp.81768-ref30">30</xref>] . This experiment was conducted during the winter season, where two different days with different amount of irradiance were considered in order to study the</p><p>behavior of PV system, in addition to the influence of cloud on the amount of the harvested power. A concept known as the degree of freedom considered describing the dynamic of shadow on the PV panel surface. The experiment outcomes indicate the effectiveness of the proposed method in all situations.</p><p>There are a number of instruments are utilized here for monitoring purpose includes two pyranometers (Kipp &amp; Zonen CM 11) to measure irradiance of the panels (daily accuracy of this pyranometer is &#177;2% and it meets the requirements for this experiment), An Agilent Hp34970A for data acquisition. The configuration of the modules is 10 panels 5 parallel-connected strings of 2 series. The complete monitoring system details can be found in [<xref ref-type="bibr" rid="scirp.81768-ref30">30</xref>] . <xref ref-type="table" rid="table1">Table 1</xref> presents the parameters of the PV considered in this experiment.</p><sec id="s4_1"><title>4.1. High Irradiance PV System</title><p>The irradiance pattern is shown <xref ref-type="fig" rid="fig2">Figure 2</xref> where the highlight reveals the intervals of shadowing detect by the sensors. Physically the solar cells of the module under PS is bypassed thus the overall active cells is reduced.</p><p>The corresponding measured DC output of the PV panels as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. The irradiance reduction can be seen clearly around 09:00 and 10:00, between 11:00 and 12:00 Also, a considerable reduction noticed around 16:00 moreover, around 13:00 a short disturbance in the grid occurs which leads to a complete inverter shutdown.</p><p>It should be mentioned here the influence of these shadows on the output power was well observed on clear days. The voltage indicators evolution is displayed in <xref ref-type="fig" rid="fig4">Figure 4</xref>, where the shadow influences the PV arrays around 09:00, between 11:00 and 12:00 and between 03:00 and 04:20 is more significant. What stands out in this figure is that, during the pre-mentioned interval indicators such as NRv seems under the voltage threshold TNRvbm.</p><p>However, reduction in DC output power of the PV arrays around 09:00 it is not because of bypassing PV modules as presented in <xref ref-type="fig" rid="fig4">Figure 4</xref>, in which a regular voltage evolution is shown by the indicators. The indicator is clearly explained the inverter disconnection.</p><p>The number of bypassing modules is depicted in <xref ref-type="fig" rid="fig5">Figure 5</xref>, and their activation</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Photovoltaic power system configuration</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Peak Power (Pmax)</th><th align="center" valign="middle" >100 w</th></tr></thead><tr><td align="center" valign="middle" >Voltage at Pmax</td><td align="center" valign="middle" >18 V</td></tr><tr><td align="center" valign="middle" >Current at Pmax</td><td align="center" valign="middle" >5.55 A</td></tr><tr><td align="center" valign="middle" >Current at Pmax</td><td align="center" valign="middle" >21.6 V</td></tr><tr><td align="center" valign="middle" >Open circuit voltage</td><td align="center" valign="middle" >21.6 V</td></tr><tr><td align="center" valign="middle" >Short circuit current</td><td align="center" valign="middle" >5.95 A</td></tr><tr><td align="center" valign="middle" >Size</td><td align="center" valign="middle" >1200 &#215; 540 &#215; 30 mm</td></tr><tr><td align="center" valign="middle" >G.W.</td><td align="center" valign="middle" >9.0 KGS</td></tr></tbody></table></table-wrap><p>is due to shadow phenomenon. The total number of connected modules is Ns = 10. <xref ref-type="fig" rid="fig5">Figure 5</xref> also significantly reveals the shadowy influence at 11:30 that cause activation of bypassing diode in 2 modules while at noon 4 PV modules are bypassed. <xref ref-type="fig" rid="fig6">Figure 6</xref> shows the zero value of the inverter current input due to the islanding prevention followed by a normal voltage build up. What stands out in <xref ref-type="fig" rid="fig6">Figure 6</xref> is that the influence of shadowing phenomenon in the reduction of PV arrays output current. Particularly at morning, before midday, and at noon is obvious. <xref ref-type="fig" rid="fig6">Figure 6</xref> also clearly determines the interval where the inverter disconnection occurs, during this interval, the inverter output current is zero and the number of faulty strings is EFs = 2 at the time of fault presence as shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>. The disconnection of the inverter can be translated as a safety measure in</p><p>order to avoid islanding. Before the midday the degradation of the current occurs because of shadow and hence the equivalent fault EFs is up to 0.47. As a result, the current of the strings is reduced by 25% of expectation.</p><p>Further, a reduction of current is detected at 09:00, also between 11:00 to 12:00, and at 03:00. Nevertheless, the amount of power reduction is higher in the morning than in the afternoon.</p></sec><sec id="s4_2"><title>4.2. Low Irradiance PV System</title><p>The irradiance associated to one day of December is presented in <xref ref-type="fig" rid="fig8">Figure 8</xref>,</p><p>where a reduction of irradiance is detected around 09:00 Accordingly a reduction in the output power of the PV arrays is observed at the same time interval, this is depicted in <xref ref-type="fig" rid="fig9">Figure 9</xref>.</p><p>Looking at <xref ref-type="fig" rid="fig1">Figure 1</xref>0, it is apparent that the shadow of the PV arrays has a very low effect on the evolution of the voltage indicators. Shadowing effects are detected at 09:00, which directly reduces the output power. However, this effect was not significant, due to presence of bypassing modules in the strings. <xref ref-type="fig" rid="fig1">Figure 1</xref>1 emphasize the fact that the number of bypassing modules has never exceeded one.</p><p>By contrast, as seen in <xref ref-type="fig" rid="fig1">Figure 1</xref>2 a reduction in the current is detected, because of partial shading at 09:00. The output power is reduced according to the current low levels at the same time intervals. Finally, what is appealing about <xref ref-type="fig" rid="fig1">Figure 1</xref>3 is that the reduction of the output current at 18:20 was not significant.</p></sec></sec><sec id="s5"><title>5. Results and Discussions</title><p><xref ref-type="table" rid="table2">Table 2</xref> and <xref ref-type="table" rid="table3">Table 3</xref> show the system losses based on two degrees of freedom. In these calculations the average values per day for each parameter is considered. In order to define the upper limit of DOF +3W is added to the average parameter, on the other hand, −3W is subtracted from the average parameter to define the lower limit of DOF.</p><p>The most interesting aspects of these two tables are the average generated power is 2.468 kW/d and 2.47 kW/d according to the upper and lower limit of DOF case of low irradiance respectively. On the other hand, when considering</p><p>high irradiance case, the average generated power is 2.359 kW/d and 2.364 kW/d associated with the upper and lower limit of DOF respectively. The key aspects of the two days under consideration are firstly, March 18, 2015 has significant irradiance over December 31, 2015. Secondly, December 31, 2015 experience lower losses than March 18, 2015. Thirdly, March 18 2015 is heavily clouded in contrast to December 31, 2015. As a result of a PS event (low irradiance) the average generated power is reduced by 0.88% and 0.64% case of upper and lower limit of DOF respectively. Within the same context, in case of high irradiance the average generated power is reduced by 5.53% and 5.32% with respect to upper</p><p>and lower limit of DOF respectively. The data presented in <xref ref-type="table" rid="table2">Table 2</xref> and <xref ref-type="table" rid="table3">Table 3</xref> indicates that the system consumption of power is reduced by 0.713% and 0.53% in low irradiance case of upper and lower limit of DOF respectively. On the other hand, in case of high irradiance 4.55% and 4.38% is reported as a reduction of system consumption.</p></sec><sec id="s6"><title>6. Conclusion</title><p>In this paper, the PV array system under partial shading caused by moving cloud was investigated. A method based in two degrees of freedom is considered. Moreover, the system was characterized in terms of losses and performances. Simulation and outdoor measurements are conducted in order to validate the</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Power loss calculation case of low irradiance</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Power losses W</th><th align="center" valign="middle" >Solar irradiance MW/m<sup>2</sup></th><th align="center" valign="middle" >System parameters</th><th align="center" valign="middle" >Values/d</th></tr></thead><tr><td align="center" valign="middle"  rowspan="10"  >18.989</td><td align="center" valign="middle"  rowspan="10"  >1.88</td><td align="center" valign="middle" >Losses upper limit</td><td align="center" valign="middle" >22.17 W</td></tr><tr><td align="center" valign="middle" >Average generation</td><td align="center" valign="middle" >2.468 kW</td></tr><tr><td align="center" valign="middle" >Reduction percentage</td><td align="center" valign="middle" >0.88%</td></tr><tr><td align="center" valign="middle" >System consumption</td><td align="center" valign="middle" >2.978 kW</td></tr><tr><td align="center" valign="middle" >Consumption reduction</td><td align="center" valign="middle" >0.713%</td></tr><tr><td align="center" valign="middle" >Losses lower limit</td><td align="center" valign="middle" >15.8 W</td></tr><tr><td align="center" valign="middle" >Average generation</td><td align="center" valign="middle" >2.47 kW</td></tr><tr><td align="center" valign="middle" >Reduction percentage</td><td align="center" valign="middle" >0.64%</td></tr><tr><td align="center" valign="middle" >System consumption</td><td align="center" valign="middle" >2.98 kW</td></tr><tr><td align="center" valign="middle" >Consumption reduction</td><td align="center" valign="middle" >0.53%</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Power loss calculation case of high irradiance</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Power losses W</th><th align="center" valign="middle" >Solar irradiance MW/m<sup>2</sup></th><th align="center" valign="middle" >System parameters</th><th align="center" valign="middle" >Values/d</th></tr></thead><tr><td align="center" valign="middle"  rowspan="10"  >127.629</td><td align="center" valign="middle"  rowspan="10"  >2.104</td><td align="center" valign="middle" >Losses upper limit</td><td align="center" valign="middle" >130.49 W</td></tr><tr><td align="center" valign="middle" >Average generation</td><td align="center" valign="middle" >2.359 kW</td></tr><tr><td align="center" valign="middle" >Reduction percentage</td><td align="center" valign="middle" >5.53%</td></tr><tr><td align="center" valign="middle" >System consumption</td><td align="center" valign="middle" >2.869 kW</td></tr><tr><td align="center" valign="middle" >Consumption reduction</td><td align="center" valign="middle" >4.55%</td></tr><tr><td align="center" valign="middle" >Lower losses limit</td><td align="center" valign="middle" >125.78 W</td></tr><tr><td align="center" valign="middle" >Average generation</td><td align="center" valign="middle" >2.364 kW</td></tr><tr><td align="center" valign="middle" >Reduction percentage</td><td align="center" valign="middle" >5.32%</td></tr><tr><td align="center" valign="middle" >System consumption</td><td align="center" valign="middle" >2.87 kW</td></tr><tr><td align="center" valign="middle" >Consumption reduction</td><td align="center" valign="middle" >4.38%</td></tr></tbody></table></table-wrap><p>proposed method. The major advantages of this method are computational efficiency, accuracy, simplicity, and the generic formulation. Based on these advantages, this method is suitable for fast loss calculation in shaded PV arrays.</p></sec><sec id="s7"><title>Cite this paper</title><p>Osman, Y.I.A., Li, J.P., Zhen, X.F. and Yang, A.R. (2018) Experimental Study of the Cloud Influence on PV Grid Connected System. Smart Grid and Renewable Energy, 9, 1-15. https://doi.org/10.4236/sgre.2018.91001</p></sec></body><back><ref-list><title>References</title><ref id="scirp.81768-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Mahela, O.P. and Shaik, A.G. (2017) Comprehensive Overview of Grid Interfaced Solar Photovoltaic Systems. Renewable and Sustainable Energy Reviews, 68, 316-332. https://doi.org/10.1016/j.rser.2016.09.096</mixed-citation></ref><ref id="scirp.81768-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Cabrera-Tobar, A., et al. (2016) Review of Advanced Grid Requirements for the Integration of Large Scale Photovoltaic Power Plants in the Transmission System. Renewable and Sustainable Energy Reviews, 62, 971-987.  
https://doi.org/10.1016/j.rser.2016.05.044</mixed-citation></ref><ref id="scirp.81768-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Seyedmahmoudian, M., et al. (2016) State of the Art Artificial Intelligence-Based MPPT Techniques for Mitigating Partial Shading Effects on PV Systems—A Review. Renewable and Sustainable Energy Reviews, 64, 435-455.  
https://doi.org/10.1016/j.rser.2016.06.053</mixed-citation></ref><ref id="scirp.81768-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Fan, X., Deng, F. and Chen, J. (2017) Voltage Band Analysis for Maximum Power Point Tracking of Stand-Alone PV Systems. Solar Energy, 144, 221-231.  
https://doi.org/10.1016/j.solener.2017.01.032</mixed-citation></ref><ref id="scirp.81768-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Ahmad, R., et al. (2017) An Analytical Approach to Study Partial Shading Effects on PV Array Supported by Literature. Renewable and Sustainable Energy Reviews, 74, 721-732. https://doi.org/10.1016/j.rser.2017.02.078</mixed-citation></ref><ref id="scirp.81768-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Roy Chowdhury, S. and Saha, H. (2010) Maximum Power Point Tracking of Partially Shaded Solar Photovoltaic Arrays. Solar Energy Materials and Solar Cells, 94, 1441-1447. https://doi.org/10.1016/j.solmat.2010.04.011</mixed-citation></ref><ref id="scirp.81768-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Syafaruddin, E.K. and Hiyama, T. (2009) Artificial Neural Network-Polar Coordinated Fuzzy Controller Based Maximum Power Point Tracking Control under Partially Shaded Conditions. IET Renewable Power Generation, 3, 239.  
https://doi.org/10.1049/iet-rpg:20080065</mixed-citation></ref><ref id="scirp.81768-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Dhimish, M., et al. (2017) Seven Indicators Variations for Multiple PV Array Configurations under Partial Shading and Faulty PV Conditions. Renewable Energy, 113, 438-460. https://doi.org/10.1016/j.renene.2017.06.014</mixed-citation></ref><ref id="scirp.81768-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Lee, J.-P., et al. (2008) A Novel Topology for Photovoltaic DC/DC Full-Bridge Converter with Flat Efficiency under Wide PV Module Voltage and Load Range. IEEE Transactions on Industrial Electronics, 55, 2655-2663.  
https://doi.org/10.1109/TIE.2008.924165</mixed-citation></ref><ref id="scirp.81768-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Balato, M., Costanzo, L. and Vitelli, M. (2016) Reconfiguration of PV Modules: A Tool to Get the Best Compromise between Maximization of the Extracted Power and Minimization of Localized Heating Phenomena. Solar Energy, 138, 105-118.  
https://doi.org/10.1016/j.solener.2016.09.011</mixed-citation></ref><ref id="scirp.81768-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Balato, M., Costanzo, L. and Vitelli, M. (2015) Series—Parallel PV Array Re-Configuration: Maximization of the Extraction of Energy and Much More. Applied Energy, 159, 145-160. https://doi.org/10.1016/j.apenergy.2015.08.073</mixed-citation></ref><ref id="scirp.81768-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">La Manna, D., et al. (2014) Reconfigurable Electrical Interconnection Strategies for Photovoltaic Arrays: A Review. Renewable and Sustainable Energy Reviews, 33, 412-426. https://doi.org/10.1016/j.rser.2014.01.070</mixed-citation></ref><ref id="scirp.81768-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Pareek, S. and Dahiya, R. (2016) Enhanced Power Generation of Partial Shaded Photovoltaic Fields by Forecasting the Interconnection of Modules. Energy, 95, 561-572. https://doi.org/10.1016/j.energy.2015.12.036</mixed-citation></ref><ref id="scirp.81768-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Pareek, S. and Dahiya, R. (2016) Series—Connected Shaded Modules to Address Partial Shading Conditions in SPV Systems. AIP Conference Proceedings, 1715, 020020. https://doi.org/10.1063/1.4942702</mixed-citation></ref><ref id="scirp.81768-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Vicente, P.D.S., Pimenta, T.C. and Ribeiro, E.R. (2015) Photovoltaic Array Reconfiguration Strategy for Maximization of Energy Production. International Journal of Photoenergy, 2015, 1-11.</mixed-citation></ref><ref id="scirp.81768-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Elanchezhian, P. and Chinnaiyan, V.K. (2017) Modeling and Simulation of High-Efficiency Interleaved Flyback Micro-Inverter for Photovoltaic Applications. Materials Today: Proceedings, 4, 10417-10421.  
https://doi.org/10.1016/j.matpr.2017.06.391</mixed-citation></ref><ref id="scirp.81768-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Kim, H., et al. (2010) A High Efficiency Photovoltaic Module Integrated Converter with the Asymmetrical Half-Bridge Flyback Converter. Solar Energy, 84, 1376-1381.  
https://doi.org/10.1016/j.solener.2010.04.019</mixed-citation></ref><ref id="scirp.81768-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Hasan, R. and Mekhilef, S. (2017) Highly Efficient Flyback Microinverter for Grid-Connected Rooftop PV System. Solar Energy, 146, 511-522.  
https://doi.org/10.1016/j.solener.2017.03.015</mixed-citation></ref><ref id="scirp.81768-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Ramli, M.Z. and Salam, Z. (2014) A Simple Energy Recovery Scheme to Harvest the Energy from Shaded Photovoltaic Modules during Partial Shading. IEEE Transactions on Power Electronics, 29, 6458-6471.  
https://doi.org/10.1109/TPEL.2014.2302007</mixed-citation></ref><ref id="scirp.81768-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Horoufiany, M. and Ghandehari, R. (2017) Optimization of the Sudoku Based Reconfiguration Technique for PV Arrays Power Enhancement under Mutual Shading Conditions. Solar Energy.</mixed-citation></ref><ref id="scirp.81768-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Pareek, S., Chaturvedi, N. and Dahiya, R. (2017) Optimal Interconnections to Address Partial Shading Losses in Solar Photovoltaic Arrays. Solar Energy, 155, 537- 551. https://doi.org/10.1016/j.solener.2017.06.060</mixed-citation></ref><ref id="scirp.81768-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Sahu, H.S., Nayak, S.K. and Mishra, S. (2016) Maximizing the Power Generation of a Partially Shaded PV Array. IEEE Journal of Emerging and Selected Topics in Power Electronics, 4, 626-637. https://doi.org/10.1109/JESTPE.2015.2498282</mixed-citation></ref><ref id="scirp.81768-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Yadav, A.S., et al. (2017) Performance Enhancement of Partially Shaded PV Array using Novel Shade Dispersion Effect on Magic-Square Puzzle Configuration. Solar Energy, 144, 780-797. https://doi.org/10.1016/j.solener.2017.01.011</mixed-citation></ref><ref id="scirp.81768-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Lappalainen, K. and Valkealahti, S. (2017) Effects of PV Array Layout, Electrical Configuration and Geographic Orientation on Mismatch Losses Caused by Moving Clouds. Solar Energy, 144, 548-555. https://doi.org/10.1016/j.solener.2017.01.066</mixed-citation></ref><ref id="scirp.81768-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Lappalainen, K. and Valkealahti, S. (2016) Analysis of Shading Periods Caused by Moving Clouds. Solar Energy, 135, 188-196.  
https://doi.org/10.1016/j.solener.2016.05.050</mixed-citation></ref><ref id="scirp.81768-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Belhachat, F. and Larbes, C. (2015) Modeling, Analysis and Comparison of Solar Photovoltaic Array Configurations under Partial Shading Conditions. Solar Energy, 120, 399-418. https://doi.org/10.1016/j.solener.2015.07.039</mixed-citation></ref><ref id="scirp.81768-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Psarros, G.N., Batzelis, E.I. and Papathanassiou, S.A. (2015) Partial Shading Analysis of Multistring PV Arrays and Derivation of Simplified MPP Expressions. IEEE Transactions on Sustainable Energy, 6, 499-508.  
https://doi.org/10.1109/TSTE.2015.2389715</mixed-citation></ref><ref id="scirp.81768-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Bosch, J.L., Zheng, Y. and Kleissl, J. (2013) Deriving Cloud Velocity from an Array of Solar Radiation Measurements. Solar Energy, 87, 196-203.  
https://doi.org/10.1016/j.solener.2012.10.020</mixed-citation></ref><ref id="scirp.81768-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Silvestre, S., et al. (2015) Analysis of Current and Voltage Indicators in Grid Connected PV (Photovoltaic) Systems Working in Faulty and Partial Shading Conditions. Energy, 86, 42-50. https://doi.org/10.1016/j.energy.2015.03.123</mixed-citation></ref><ref id="scirp.81768-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Feng, R., et al. (2016) Performance of a Novel Household Solar Heating Thermostatic Biogas System. Applied Thermal Engineering, 96, 519-526.  
https://doi.org/10.1016/j.applthermaleng.2015.12.003</mixed-citation></ref><ref id="scirp.81768-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Belhachat, F. and Larbes, C. (2017) Global Maximum Power Point Tracking Based on ANFIS Approach for PV Array Configurations under Partial Shading Conditions. Renewable and Sustainable Energy Reviews, 77, 875-889.  
https://doi.org/10.1016/j.rser.2017.02.056</mixed-citation></ref><ref id="scirp.81768-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Belhaouas, N., et al. (2017) PV Array Power Output Maximization under Partial Shading using New Shifted PV Array Arrangements. Applied Energy, 187, 326-337.  
https://doi.org/10.1016/j.apenergy.2016.11.038</mixed-citation></ref><ref id="scirp.81768-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Wolff, B., et al. (2016) Comparing Support Vector Regression for PV Power Forecasting to a Physical Modeling Approach using Measurement, Numerical Weather Prediction, and Cloud Motion Data. Solar Energy, 135, 197-208.  
https://doi.org/10.1016/j.solener.2016.05.051</mixed-citation></ref><ref id="scirp.81768-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Dolara, A., et al. (2013) Experimental Investigation of Partial Shading Scenarios on PV (Photovoltaic) Modules. Energy, 55, 466-475.  
https://doi.org/10.1016/j.energy.2013.04.009</mixed-citation></ref></ref-list></back></article>