<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">IJOC</journal-id><journal-title-group><journal-title>International Journal of Organic Chemistry</journal-title></journal-title-group><issn pub-type="epub">2161-4687</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ijoc.2017.74025</article-id><article-id pub-id-type="publisher-id">IJOC-80342</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Direct Mass Spectroscopy Analysis and Comparison of Middle Eastern and Texas Crude Oils
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Gamze</surname><given-names>Kaya</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Necati</surname><given-names>Kaya</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mahmood</surname><given-names>Amani</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Abul</surname><given-names>H. M. J. Rahman</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Alexandre</surname><given-names>A. Kolomenskii</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hans</surname><given-names>A. Schuessler</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff3"><addr-line>Petroleum Engineering Program, Texas A &amp;amp; M University at Qatar, Doha, Qatar</addr-line></aff><aff id="aff4"><addr-line>Department of Physics, Texas A &amp;amp; M University, College Station, TX, USA</addr-line></aff><aff id="aff1"><addr-line>Vocational School of Technical Sciences, Canakkale Onsekiz Mart University, Canakkale, Turkey</addr-line></aff><aff id="aff2"><addr-line>Faculty of Arts and Sciences, Giresun University, Giresun, Turkey</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>gamzekaya@comu.edu.tr(GK)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>25</day><month>10</month><year>2017</year></pub-date><volume>07</volume><issue>04</issue><fpage>312</fpage><lpage>318</lpage><history><date date-type="received"><day>28,</day>	<month>September</month>	<year>2017</year></date><date date-type="rev-recd"><day>13,</day>	<month>November</month>	<year>2017</year>	</date><date date-type="accepted"><day>16,</day>	<month>November</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  We analyzed two types of crude oil samples: Middle Eastern crude oil and Texas crude oil by using a residual gas analyzer (RGA) based on the linear quadrupole principle. This portable mass analyzer is capable of measuring hydrocarbons with masses of up to 300 atomic mass units (amu) as well as low mass targets, such as methane and carbon dioxide at ppm level concentrations. The generated mass spectra revealed differences in the composition and signal intensity of hydrocarbons of Middle Eastern and Texas crude oil samples. Even if RGA 300 is manufactured to be served as a detailed gas analysis of vacuum systems, we have shown that it is sensitively capable of detection of hydrocarbons and it enables one to qualitative and quantitative analysis of the composition of the crude oils.
 
</p></abstract><kwd-group><kwd>Oil Composition</kwd><kwd> Mass Spectrum Analysis</kwd><kwd> Hydrocarbons Content</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Hydrocarbon-water phase behavior and solubility at high temperature and high pressure is very complex and varies widely. Moreover, extracting crude oil from HPHT (high pressure and high temperature) reservoir zones like the Texas Woodbine-Eagle Ford, the North Sea or the Middle Eastern fields, and preserving its original condition for analysis is costly and done only rarely [<xref ref-type="bibr" rid="scirp.80342-ref1">1</xref>] . The next best alternative is to have sample-testing equipment at the extraction point or at the well bore. Even when such samples are not analyzed at their down-hole condition, such remotely obtained and detailed data are a prerequisite in estimating the structure and capacity of wells, and for such analysis sensitive and selective equipment is required. At the same time this equipment must be rugged, since the wide range of hydrocarbons including heavy asphaltenes are in a mixed phase with water, crude oil and drilling mud.</p><p>The present work was performed in the laboratory since the samples came from the Middle East and from Texas. As is detailed below, the mass spectrometry profiles of the samples revealed their composition differences.</p><p>As an analytical method, mass spectrometry provides qualitative and quantitative analysis of the chemical compositions of a sample investigated, and for this purpose, several types of mass spectrometers have been produced and improved to serve for various applications. In recent years, the miniaturization of mass spectrometers, for example time-of-flight spectrometers [<xref ref-type="bibr" rid="scirp.80342-ref2">2</xref>] , ion traps [<xref ref-type="bibr" rid="scirp.80342-ref3">3</xref>] , sector mass filters [<xref ref-type="bibr" rid="scirp.80342-ref4">4</xref>] , and quadrupoles [<xref ref-type="bibr" rid="scirp.80342-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.80342-ref6">6</xref>] , has been given much consideration, so that such a device can be portable for field applications, while showing sufficient performance. Main advantages of these recent miniaturized mass analyzers are their lower cost and power consumption and the ability to operate at higher pressures and with smaller and less expensive vacuum systems [<xref ref-type="bibr" rid="scirp.80342-ref7">7</xref>] .</p><p>Crude oil contains a variety of organic compounds; therefore, different techniques are required for detailed analysis of crude oil samples. While the determination of volatile and non-polar components has been achieved by gas chromatography/mass spectrometry (GC/MS), the identification of trace polar components in crude oil is performed using liquid chromatography/mass spectrometry (LC/MS) [<xref ref-type="bibr" rid="scirp.80342-ref8">8</xref>] . Mass spectrometric ionization techniques, namely, electron impact ionization (EI) [<xref ref-type="bibr" rid="scirp.80342-ref9">9</xref>] , field ionization (FI) [<xref ref-type="bibr" rid="scirp.80342-ref10">10</xref>] , and field desorption (FD) [<xref ref-type="bibr" rid="scirp.80342-ref11">11</xref>] are sufficient for analysis of volatile and semi volatile compounds in crude oil [<xref ref-type="bibr" rid="scirp.80342-ref8">8</xref>] . For the analysis of the compounds with higher boiling points, producing characteristic fragments, pyrolysis/mass spectrometry (Py/MS) or pyrolysis/gas chromatography/mass spectrometry (Py/GC/MS) needs to be considered [<xref ref-type="bibr" rid="scirp.80342-ref12">12</xref>] . Matrix-assisted laser desorption ionization/mass spectrometry (MALDI/MS) with the capability of detecting compounds in a wide range of mass-to-charge ratios is an effective method used for crude oil analysis in vacuum environment [<xref ref-type="bibr" rid="scirp.80342-ref13">13</xref>] . Electrospray ionization (ESI) [<xref ref-type="bibr" rid="scirp.80342-ref14">14</xref>] and atmospheric pressure photoionization (APPI) [<xref ref-type="bibr" rid="scirp.80342-ref15">15</xref>] are the other techniques used for crude oil analysis, but they require expensive instruments and complicated sample pretreatment.</p><p>We performed hydrocarbon analysis of crude oil with mass spectrometry, introducing the sample directly to the vacuum chamber without any prior sample preparation. A vacuum environment decreases the boiling temperature of the compounds drastically, and room temperature is enough for vaporization of most components from crude oil samples, therefore the signal is observed immediately.</p></sec><sec id="s2"><title>2. Experimental Procedure</title><p>To analyze Middle Eastern crude oil and Texas crude oil samples, which were obtained from the Middle Eastern fields and Texas Eagle Ford reservoir, respectively, we used the portable quadrupole mass analyzer (RGA300, Stanford Research Systems), which has RF frequencies in the several MHz range and quadrupole electrodes to separate different molecules. This portable mass analyzer has small dimensions, a mass range 1 - 300 amu and the resolution better than 1 amu. The samples were injected into the vacuum chamber through a leak valve, and ions are produced by electron impact ionization. Thereby the electrons are produced by thermionic emission from a hot filament. Then by applying the radiofrequency field, the ions are separated according to their mass-to-charge ratios. The mass spectrometer is connected directly to a vacuum chamber, which contains vapor from the sample, as is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. The spectrometer employs zero order (DC current for balancing the potential relative to the kinetic energy) and first order (AC current with resonance frequency corresponding to mass over charge ratio) operation modes for detecting ions. These frequency domains multiplexed measurements give a high signal to noise ratio.</p><p>Besides the quadrupole probe, the RGA system includes an electronics control unit, and a real-time RGA Windows software, which is used for probe control, data acquisition and analysis. The probe unit consists of three parts: an ionizer, a quadrupole mass filter and an ion detector. The electronic control unit allows controlling the operation of the RGA and transmits the obtained data to the</p><p>computer, where the data are displayed and analyzed. The electron emission is supplied by a dual thoriated-iridium (ThO<sub>2</sub>/Ir) filament, which lasts longer than single filaments. A Faraday cup detector allows partial pressure measurements in the range of 10<sup>−5</sup> - 10<sup>−11</sup> mbar. An electron continuous-dynode electron multiplier (CDEM), with high sensitivity and fast scan rates is capable of detecting partial pressures down to 10<sup>−14</sup> mbar. Finally, a high vacuum system turbomolecular pumping station TSU 071 provided by Pfeiffer Vacuum is connected with the residual gas analyzer. It assures low background pressure (~7.8 &#215; 10<sup>−7</sup> mbar) and enables maintenance of operational pressure for measurements at ~5.2 &#215; 10<sup>−6</sup> mbar.</p></sec><sec id="s3"><title>3. Results and Discussions</title><p>The generated mass spectra and signal intensity of hydrocarbons in Middle Eastern and Texas crude oil samples are displayed together in Figures 2-4. The total measured range of mass-to-charge ratios was divided into three regions chosen at random for interpretation of data and comparison of the mass spectra: (a) 50 - 90 amu (<xref ref-type="fig" rid="fig2">Figure 2</xref>); (b) 90 - 130 amu (<xref ref-type="fig" rid="fig3">Figure 3</xref>); and (c) 130 - 171 amu (<xref ref-type="fig" rid="fig4">Figure 4</xref>).</p><p>Three major types of hydrocarbons in crude oil, i.e. paraffins, naphthenes, and aromatics are detected in both types of investigated samples. We observed linear and saturated hydrocarbons with mass-to-charge ratios 57, 71, 85, 99, 113, 127, 141, 155, 169 amu and naphthenes (or cycloalkanes) with mass-to-charge ratios 55, 69, 83, 97, 111, 125, 139, 153, 167 amu. The aromatics seen with mass-to-charge ratios 77 - 78, 91 - 92, 105 - 106, 119 - 120, 133 - 134 amu are characteristic of benzene derivatives. Toxic aromatic hydrocarbons, i.e. benzene, toluene, and xylene, with mass-to-charge ratios 77 - 78, 91 - 92, and 105 - 106 amu, respectively [<xref ref-type="bibr" rid="scirp.80342-ref16">16</xref>] , are seen in both samples with significantly different signal intensities. The weak signals observed around mass-to-charge ratios 128 amu and 141 - 142 amu might be indicating the presence of naphtalene and methylnaphtalenes, respectively. While we have seen the peaks at 169 and 171 amu in Middle Eastern crude oil, no such peaks were detected in Texas crude oil. We measured the whole mass range of our mass analyzer 1 - 300 amu, but above 171 amu we did not detect any peaks in both samples. The abundance of hydrocarbons with higher mass-to-charge ratios in the region 91 - 171 amu in Texas crude oil is significantly lower compared to Middle Eastern crude oil, as seen in <xref ref-type="fig" rid="fig3">Figure 3</xref> and <xref ref-type="fig" rid="fig4">Figure 4</xref>. In <xref ref-type="fig" rid="fig5">Figure 5</xref>, the partial pressure ratio of different mass spectrum components of both crude oils by dividing pressure ratios of Middle Eastern crude oil to Texas crude oil is plotted, and it shows that the abundance of hydrocarbons of Middle Eastern crude oil compared to Texas crude oil is higher by a factor that ranges for different components from 4 to 21.</p></sec><sec id="s4"><title>4. Conclusion</title><p>Analysis of two different types of crude oil samples, Middle Eastern crude oil from the Middle Eastern fields and Texas crude oil obtained from Texas Eagle Ford reservoir zones, by the portable quadrupole mass analyzer under vacuum condition without any sample pretreatment is performed. The mass spectra of these two types of oil samples show differences. The Middle Eastern crude oil samples show significant prevalence of hydrocarbons in the range of 90 - 160 amu.</p><p>Moreover, two crude oil samples reveal some differences in composition. We observed C12 paraffin, naphthene, and aromatic hydrocarbons only in Middle Eastern crude oil. Even though our measurements were done at the laboratory conditions, due to portability and rather small size of the equipment, the same approach is suitable for in-field applications if needed.</p></sec><sec id="s5"><title>Acknowledgements</title><p>This work was supported by the Robert A. Welch Foundation (grant No. A1546).</p></sec><sec id="s6"><title>Cite this paper</title><p>Kaya, G., Kaya, N., Amani, M., Rahman, A.H.M.J., Kolomenskii, A.A. and Schuessler, H.A. (2017) Direct Mass Spectroscopy Analysis and Comparison of Middle Eastern and Texas Crude Oils. International Journal of Organic Chemistry, 7, 312-318. https://doi.org/10.4236/ijoc.2017.74025</p></sec></body><back><ref-list><title>References</title><ref id="scirp.80342-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Shadravan, A. and Amani, M. (2012) HPHT 101-What Petroleum Engineers and Geoscientists Should Know about High Pressure High Temperature Wells Environment. Energy Science and Technology, 4, 36-60.</mixed-citation></ref><ref id="scirp.80342-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Cotter, R.J., Fancher, C. and Cornish, T.J. (1999) Miniaturized Time-of-Flight Mass Spectrometer for Peptide and Oligonucleotide Analysis. Journal of Mass Spectrometry, 34, 1368-1372. https://doi.org/10.1002/(SICI)1096-9888(199912)34:12&lt;1368::AID-JMS905&gt;3.0.CO;2-S</mixed-citation></ref><ref id="scirp.80342-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Ouyang, Z., Wu, G., Song, Y., Li, H., Plass, W.R. and Cooks, R.G. (2004) Rectilinear Ion Trap: Concepts, Calculations, and Analytical Performance of a New Mass Analyzer. Analytical Chemistry, 76, 4595-4605. https://doi.org/10.1021/ac049420n</mixed-citation></ref><ref id="scirp.80342-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Sinha, M.P. and Tomassian, A.D. (1991) Development of a Miniaturized, Light-Weight Magnetic Sector for a Field-Portable Mass Spectrograph. Review of Scientific Instruments, 62, 2618-2620. https://doi.org/10.1063/1.1142240</mixed-citation></ref><ref id="scirp.80342-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Freidhoff, C.B., et al. (1999) Chemical Sensing Using Non-Optical Microelectromechanical Systems. Journal of Vacuum Science &amp; Technology A, 17, 2300-2307.https://doi.org/10.1116/1.581764</mixed-citation></ref><ref id="scirp.80342-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Badman, E.R. and Cooks, R.G. (2000) Miniature Mass Analyzers. Journal of Mass Spectrometry, 35, 659-671. https://doi.org/10.1002/1096-9888(200006)35:6&lt;659::AID-JMS5&gt;3.0.CO;2-V</mixed-citation></ref><ref id="scirp.80342-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Brkic, B., France, N., Clare, A.T., Sutcliffe, C.J., Chalker, P.R. and Taylor, S. (2011) Development of Quadrupole Mass Spectrometers Using Rapid Prototyping Technology. Journal of the American Society for Mass Spectrometry, 20, 1359-1365.https://doi.org/10.1016/j.jasms.2009.03.025</mixed-citation></ref><ref id="scirp.80342-ref8"><label>8</label><mixed-citation publication-type="book" xlink:type="simple">Cheng, C.N., Lai, J.H., Huang, M.Z., Oung, J.N. and Shiea, J. (2012) Analysis of Polar Components in Crude Oil by Ambient Mass Spectrometry. In: El-Sayed Abdul-Raouf, M., Ed., Crude Oil Emulsions, Composition Stability and Characterization, InTech, 107-120. https://doi.org/10.5772/36261</mixed-citation></ref><ref id="scirp.80342-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Flego, C. and Zannoni, C. (2010) Direct Insertion Probe-Mass Spectrometry: A Useful Tool for Characterization of Asphaltenes. Energy &amp; Fuels, 24, 6041-6053.https://doi.org/10.1021/ef100984y</mixed-citation></ref><ref id="scirp.80342-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Hsu, C.S. and Green, M. (2001) Fragment-Free Accurate Mass Measurement of Complex Mixture Components by Gas Chromatography/Field Ionization-Orthogonal Acceleration Time-of-Flight Mass Spectrometry: An Unprecedented Capability for Mixture Analysis. Rapid Communications in Mass Spectrometry, 15, 236-239. https://doi.org/10.1002/1097-0231(20010215)15:3&lt;236::AID-RCM197&gt;3.0.CO;2-B</mixed-citation></ref><ref id="scirp.80342-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Stanford, L.A., Kim, S., Klein, G.C., Smith, D.F., Rodgers, R.P. and Marshall, A.G. (2007) Identification of Water-Soluble Heavy Crude Oil Organic-Acids, Bases, and Neutrals by Electrospray Ionization and Field Desorption Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Environmental Science &amp; Technology, 41, 2696-2702. https://doi.org/10.1021/es0624063</mixed-citation></ref><ref id="scirp.80342-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Snyder, A.P., McClennen, W.H., Dworzanski, J.P. and Meuzelaar, H.L.C. (1990) Characterization of Underivatized Lipid Biomarkers from Microorganisms with Pyrolysis Short-Column Gas Chromatography/Ion Trap Mass Spectrometry. Analytical Chemistry, 62, 2565-2573. https://doi.org/10.1021/ac00222a010</mixed-citation></ref><ref id="scirp.80342-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Robins, C. and Limbach, P.A. (2003) The Use of Nonpolar Matrices for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Analysis of High Boiling Crude Oil Fractions. Rapid Communications in Mass Spectrometry, 17, 2839-2845. https://doi.org/10.1002/rcm.1275</mixed-citation></ref><ref id="scirp.80342-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Zhan, D. and Fenn, J.B. (2000) Electrospray Mass Spectrometry of Fossil Fuels. International Journal of Mass Spectrometry, 194, 197-208.https://doi.org/10.1016/S1387-3806(99)00186-4</mixed-citation></ref><ref id="scirp.80342-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Purcell, J.M., Hendrickson, C.L., Rodgers, R.P. and Marshall, A.G. (2006) Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for Complex Mixture Analysis. Analytical Chemistry, 78, 5906-5912.https://doi.org/10.1021/ac060754h</mixed-citation></ref><ref id="scirp.80342-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Brkic, B., France, N. and Taylor, S. (2011) Oil-in-Water Monitoring Using Membrane Inlet Mass Spectrometry. Analytical Chemistry, 83, 6230-6236.https://doi.org/10.1021/ac2008042</mixed-citation></ref></ref-list></back></article>