<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJCE</journal-id><journal-title-group><journal-title>Open Journal of Civil Engineering</journal-title></journal-title-group><issn pub-type="epub">2164-3164</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojce.2017.73026</article-id><article-id pub-id-type="publisher-id">OJCE-78463</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Non-Destructive Imaging of Water Permeation through Cementitious Materials Using MRI
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yuya</surname><given-names>Sakai</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yuki</surname><given-names>Yokoyama</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Toshiharu</surname><given-names>Kishi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Institute of Industrial Science, The University of Tokyo, Tokyo, Japan</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>ysakai@iis.u-tokyo.ac.jp(YS)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>20</day><month>07</month><year>2017</year></pub-date><volume>07</volume><issue>03</issue><fpage>378</fpage><lpage>388</lpage><history><date date-type="received"><day>July</day>	<month>13,</month>	<year>2017</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>August</month>	<year>12,</year>	</date><date date-type="accepted"><day>August</day>	<month>15,</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this study, water permeation through cementitious materials was observed using magnetic resonance imaging (MRI). The influence of cement type on the magnetic resonance signal was studied subsequent to determining the parameters required for imaging. Consequently, adequate imaging of water permeating through hardened cement paste (HCP) made with white Portland cement was achieved, while water permeation through ordinary Portland cement-based HCP yielded poor signal. HCPs maintained at various levels of relative humidity (RH) were observed, and the signal was detected only from those maintained at an RH of higher than 85%. The water permeation depths in HCP were observed by using MRI, and the measured depths were compared to those measured via a spraying water detector on the split surface of the specimens. As a result, good agreement was confirmed between the two methods. Additionally, MRI was applied to concrete specimens; although it was found that water was not detected when a lightweight aggregate was used, water permeation through concrete with limestone aggregate was detectable via MRI. MRI will help in understanding how water permeation causes and accelerates concrete deteriorations such as rebar corrosion and freezing and thawing.
 
</p></abstract><kwd-group><kwd>MRI</kwd><kwd> Cement Paste</kwd><kwd> Concrete</kwd><kwd> Water Permeation</kwd><kwd> Non-Destructive Testing</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Water is known to yield deleterious effects on concrete structures. To observe the depth of water permeation through concrete, the concrete specimen can be split to measure the depth of the surface colour changes [<xref ref-type="bibr" rid="scirp.78463-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.78463-ref2">2</xref>] . However, the determination of water permeation depth in concrete is difficult because 70% to 80% of the split surface area is aggregate, and the colour change due to permeated water is generally only visible in the cement paste. Some researchers have cut concrete specimens and dried them to evaluate mass changes due to water transfer, and to determine the moisture distribution [<xref ref-type="bibr" rid="scirp.78463-ref3">3</xref>] . Alternatively, humidity sensors can be used to measure the moisture distribution [<xref ref-type="bibr" rid="scirp.78463-ref4">4</xref>] or water penetration depth in concrete [<xref ref-type="bibr" rid="scirp.78463-ref5">5</xref>] . Justnes et al. [<xref ref-type="bibr" rid="scirp.78463-ref6">6</xref>] and Pleinert et al. [<xref ref-type="bibr" rid="scirp.78463-ref7">7</xref>] applied neutron radiography to observe water in cementitious materials; however, it was found that the sample thickness had to be limited to a few centimetres to allow the neutron ray to completely pass through the sample. The above methods only yield one- to two-dimensional information.</p><p>In this paper, magnetic resonance imaging (MRI) was used to observe water permeation through concrete. MRI can acquire three-dimensional information because it receives radio-frequency signals from any position in the sample at which hydrogen atoms are present. Moreover, it is non-destructive and enables the observation of water movement in real time. However, a disadvantage of this method is that, as strong magnets are implemented, MRI cannot be applied to reinforced concrete because of the strong attraction of steel; additionally, magnetic materials such as steel bars cause distortion of the obtained images. In their study using MRI to observe concrete structures, Marfisi et al. [<xref ref-type="bibr" rid="scirp.78463-ref8">8</xref>] reported that magnetic components in ordinary Portland cement (OPC) affect the captured images. In addition, Marfisi et al. [<xref ref-type="bibr" rid="scirp.78463-ref9">9</xref>] employed MRI to evaluate fractures in concrete. They reported that limestone and quartz aggregates are preferred to observe concrete via MRI and that granite is not suitable. Kaufmann et al. [<xref ref-type="bibr" rid="scirp.78463-ref10">10</xref>] implemented MRI to observe water permeation through concrete specimens, but as they used OPC, the obtained images were not clear. It was found that deuterated water can yield marginal improvements in the image, but it is expensive. Additionally, Kaufmann et al. did not explicitly confirm whether the penetration depth captured via MRI was correct, as they merely calculated the depth via determination of mass increase due to immersion, which was accomplished by comparing the dry and saturated masses.</p><p>The objective of this paper is to study the applicability of MRI to the observation of water permeation through concrete. To begin, the necessary parameters for MRI were determined by evaluating the hardened cement paste (HCP) made with white Portland cement (WPC). WPC was used because magnetic components in OPC affected the captured image, as will be discussed in a later section. Then, HCPs made with WPC and maintained at various levels of relative humidity (RH) were observed via MRI to determine the threshold of water detection. Next, HPCs dried at various temperatures were soaked in water; the permeation depth was subsequently imaged via MRI, and the observed depth was compared to the depth as measured on the splitting surface. Lastly, concrete specimens with lightweight aggregate (LWA) and limestone aggregate (LSA) were prepared and observed via MRI to determine the effects of aggregates on the obtained images. Concrete with the commonly used granite aggregate was not studied because Marfisi et al. [<xref ref-type="bibr" rid="scirp.78463-ref8">8</xref>] has already reported that the obtained MRI image of concrete containing granite was distorted.</p></sec><sec id="s2"><title>2. MRI Background Information (Hashemi et al. [<xref ref-type="bibr" rid="scirp.78463-ref11">11</xref>] )</title><p>The general principle of MRI is that it constructs images from the signal emitted from the hydrogen nuclei in the object under observation. To image, a strong magnetic field is first applied to the object. When an object containing hydrogen atoms enters the external magnetic field, the spin of the nuclei is oriented to the direction of the magnetic field; this direction is generally assumed as the Z axis. When a radio-frequency pulse with the same frequency as the proton spin is applied to the object, the axis of the spin inclines towards the X-Y plane, which is orthogonal to the Z axis. This inclination angle is called the flip angle. The inclined spin is recovered towards the Z axis after the radio-frequency pulse has ceased. Thus, MRI constructs images according to the signal that is emitted from the hydrogen nuclei as the spin recovers from the X-Y plane to the Z axis. The parameters describing the recovery of the Z-axis component (M<sub>z</sub>) and decay of the X-Y-plane component (M<sub>XY</sub>) are T<sub>1</sub> and T<sub>2</sub>, respectively. T<sub>1</sub> and T<sub>2</sub> show the relaxation curves expressed by Equation (1) and Equation (2), respectively.</p><disp-formula id="scirp.78463-formula141"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-1880835x2.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.78463-formula142"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-1880835x3.png"  xlink:type="simple"/></disp-formula><p>T<sub>1</sub> and T<sub>2</sub> vary according to the mobility of hydrogen nuclei. The parameters for MRI observation must be optimized to obtain a clear image. The echo time (T<sub>E</sub>: time interval between radio-frequency pulse and signal acquisition) and repetition time (T<sub>R</sub>: time interval of radio-frequency pulse) are the most important parameters.</p><p>Marfisi et al. [<xref ref-type="bibr" rid="scirp.78463-ref8">8</xref>] used T<sub>E</sub> = 3.5 ms and T<sub>R</sub> = 100 ms to obtain MRI images of water in concrete. However, these T<sub>E</sub> and T<sub>R</sub> values cannot be used because these parameters vary according to the magnetic density. Marfisi et al. employed MRI with a magnetic density of 2 T, while the MRI used in this study applies 3 T. T<sub>2</sub> is obtained only when a perfectly uniform external magnetic field is applied; however, as real external magnetic fields are always non-uniform, the actual acquired signal is denoted as<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x4.png" xlink:type="simple"/></inline-formula>, in distinction from T<sub>2</sub>.</p></sec><sec id="s3"><title>3. Experimental Methods</title><sec id="s3_1"><title>3.1. Specimens</title><p>The material properties are shown in <xref ref-type="table" rid="table1">Table 1</xref>. HPCs of φ 50 &#215; 100 mm and water-to-cement ratio (W/C) of 0.4 were respectively prepared using OPC and WPC. The specimens used to study the effects of RH via imaging were seal- cured up to 28 days following casting, and then maintained at a temperature of 20˚C under 60% RH for 1 month. These specimens were cut into 2-cm-thick slices via a water-cooling cutter and dried under conditions of 20˚C and 60% RH</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Material specifications</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Cement</th><th align="center" valign="middle" >Ordinary Portland cement (density: 3.15 g/cm<sup>3</sup>, specific surface area: 4110 cm<sup>2</sup>/g) White Portland cement (density: 3.05 g/cm<sup>3</sup>, specific surface area: 3440 cm<sup>2</sup>/g)</th></tr></thead><tr><td align="center" valign="middle" >Sand</td><td align="center" valign="middle" >Artificial lightweight sand (oven-dry density: 1.65 g/cm<sup>3</sup>, water absorption: 15%, FM: 2.75) Limestone sand (surface dry density: 2.65 g/cm<sup>3</sup>, water absorption: 2.42%, FM: 3.60)</td></tr><tr><td align="center" valign="middle" >Gravel</td><td align="center" valign="middle" >Artificial lightweight gravel (oven-dry density: 1.29 g/cm<sup>3</sup>, maximum size: 20 mm, water absorption: 28%, FM: 6.35) Limestone gravel (surface dry density: 2.70 g/cm<sup>3</sup>, maximum size: 20 mm, water absorption: 0.41%, FM: 7.68)</td></tr></tbody></table></table-wrap><p>for 2 weeks. Then, these cut samples were stored in desiccators at 76%, 85%, 98% or 100% RH for 1 month and subsequently imaged via MRI. After MRI, the samples were oven-dried at 105˚C for three days, and mass decrease of the sample due to drying was divided by the mass of the sample after it was oven-dried to evaluate moisture content. In a similar manner, HPCs used to evaluate the effects of cement type were seal-cured for 28 days subsequent to casting. These specimens were dried under conditions of 20˚C and 60% RH for 1 month, 40˚C and 10% RH for 2 weeks or 105˚C for 3 d. After drying, they were each soaked in 1-cm-deep water for 3 d in a covered container prior to imaging as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. Then, the specimens were split and a water leakage testing agent, MORAYMILLE (TASETO, Kanagawa, Japan), was applied to measure the water permeation depth.</p><p>The material properties and mix design of the concrete specimens are provided in <xref ref-type="table" rid="table1">Table 1</xref> and <xref ref-type="table" rid="table2">Table 2</xref>, respectively. WCP was used to prepare concrete specimens of φ 100 &#215; 200 mm. Concrete specimens with LWA were demoulded 24 h after casting and dried at 105˚C for 6 d. The specimens were then soaked in 1-cm-deep water for 3 d and imaged via MRI. Three concrete specimens with LSA were cast; of these, two of them were demoulded 24 h after casting and dried at 105˚C or 20˚C (60% RH) until MRI imaging was performed at an age of 48 h. The remaining specimen was demoulded immediately prior to MRI imaging following 48 h aging. After imaging, the specimens maintained at 105˚C were once again stored at 105˚C, while the remaining specimens were stored in a 20˚C chamber under 60% RH. Once aged for 18 d, they were each soaked in 1-cm-deep water in an open-air container for 2 d prior to secondary imaging.</p></sec><sec id="s3_2"><title>3.2. Pore Structure Analysis</title><p>The pore structure of the HCPs dried under conditions of 40˚C and 10% RH for 2 weeks was analysed via mercury intrusion porosimetry (MIP). The samples for MIP were collected from the HCP at depths greater than 2 cm from the surface. The collected samples were subsequently immersed in acetone for 24 h and dried for 24 h via the D-Dry method, in which the sample is equilibrated with ice at −79˚C, prior to performing MIP.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Schematic of water absorption (in covered container)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x5.png"/></fig><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Mix design</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Name</th><th align="center" valign="middle"  rowspan="2"  >Aggregate type</th><th align="center" valign="middle"  rowspan="2"  >W/C (%)</th><th align="center" valign="middle"  colspan="4"  >Mass per unit volume (kg/m<sup>3</sup>)</th></tr></thead><tr><td align="center" valign="middle" >W</td><td align="center" valign="middle" >C</td><td align="center" valign="middle" >S</td><td align="center" valign="middle" >G</td></tr><tr><td align="center" valign="middle" >Concrete with LWA</td><td align="center" valign="middle" >Lightweight</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >174</td><td align="center" valign="middle" >316</td><td align="center" valign="middle" >535</td><td align="center" valign="middle" >601</td></tr><tr><td align="center" valign="middle" >Concrete with LSA</td><td align="center" valign="middle" >Limestone</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >170</td><td align="center" valign="middle" >283</td><td align="center" valign="middle" >774</td><td align="center" valign="middle" >1087</td></tr></tbody></table></table-wrap></sec><sec id="s3_3"><title>3.3. Determination of T<sub>1</sub> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x6.png" xlink:type="simple"/></inline-formula></title><p>The MAGNETOM Prisma MRI (SIEMENS, Munich, Germany), equipped with a magnetic flux density of 3 T, was used for MRI imaging. To determine the optimum parameters for imaging the prepared samples, the relaxation times of T<sub>1</sub> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x7.png" xlink:type="simple"/></inline-formula> were studied. T<sub>1</sub> was calculated via the following equation.</p><disp-formula id="scirp.78463-formula143"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-1880835x8.png"  xlink:type="simple"/></disp-formula><p>In this study, the flip angles α<sub>1</sub> = 11˚ and α<sub>2</sub> = 56˚ were used to acquire the signals S<sub>1</sub> and S<sub>2</sub>, respectively.</p><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x9.png" xlink:type="simple"/></inline-formula>was determined by applying two different values of T<sub>E</sub> and subsequently solving the following equation to fit the signals obtained in the resulting image.</p><disp-formula id="scirp.78463-formula144"><label>(4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-1880835x10.png"  xlink:type="simple"/></disp-formula><p>In this study, T<sub>E</sub> values of 0.87 and 1.2 ms were used, and the obtained M<sub>XY</sub>s were substituted into Equation (4) to determine<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x11.png" xlink:type="simple"/></inline-formula>. The resulting relaxation curves for T<sub>1</sub> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x12.png" xlink:type="simple"/></inline-formula> are illustrated in Section 4.1 for T<sub>E</sub> and T<sub>R</sub> set to 1.19 and 8.4 ms, respectively. Although the resolution of constructed images can be improved by repeating acquired signals, a resolution (the size of an imaging voxel) of 1 &#215; 1 &#215; 1 mm was used in this study without repetition because this resolution is sufficient to measure the depth of water permeation through cementitious material. The required time to acquire a single image was approximately 2 min.</p></sec></sec><sec id="s4"><title>4. Results and Discussion</title><sec id="s4_1"><title>4.1. Determining Imaging Parameters</title><p>T<sub>1</sub> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x13.png" xlink:type="simple"/></inline-formula> were studied to determine the optimum parameters for imaging. The signal intensity obtained with α<sub>1</sub> = 11˚ and α<sub>2</sub> = 56˚ were 181 and 697, respectively. Substituting these values into Equation (3) yields T<sub>1</sub> = 6.88 ms. The signal intensity acquired by implementing T<sub>E</sub> = 0.87 and 1.2 ms were 2207 and 623, respectively. Subsequently, the value of <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x14.png" xlink:type="simple"/></inline-formula> obtained by substituting the above values into Equation (4) and performing fitting was 0.26 ms. These T<sub>1</sub> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x15.png" xlink:type="simple"/></inline-formula> values are very short as compared to those of bulk water, which are each approximately 2500 ms [<xref ref-type="bibr" rid="scirp.78463-ref11">11</xref>] . Dissolved ions in water and small pores are known to decrease T<sub>1</sub> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x16.png" xlink:type="simple"/></inline-formula> [<xref ref-type="bibr" rid="scirp.78463-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.78463-ref12">12</xref>] . <xref ref-type="fig" rid="fig2">Figure 2</xref> shows the calculated relaxation curves for M<sub>Z</sub> and M<sub>XY</sub> assuming M<sub>0</sub> = 1. M<sub>XY</sub> can be observed to decay faster than M<sub>Z</sub>; M<sub>XY</sub> decreased to one-thousandth of M<sub>0</sub> at 1.8 ms; this indicates that T<sub>E</sub> and T<sub>R</sub> should be set small to acquire a strong signal. Thus, in this study, T<sub>E</sub> and T<sub>R</sub> were set to 1.19 ms and 8.4 ms, respectively.</p></sec><sec id="s4_2"><title>4.2. Effects of Relative Humidity</title><p>Acquired images of specimens stored at various levels of RH are shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. Images of the specimens maintained at higher levels of RH are visibly clearer, as indicated by the contrast, while the specimens maintained at 76% and 85% RH do not yield a strong contrast. The masses of specimens maintained at 98% and 100% RH exhibited continuing increase at the time of MRI imaging. This result indicates that the specimens maintained at RHs of lower than 85% did not emit a sufficiently strong signal, and that stronger signals will be acquired from specimens maintained at 98% and 100% RH at constant mass.</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Relaxation curves: M<sub>Z</sub> and M<sub>XY</sub></title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x17.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Images of cement pastes under various levels of RH</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x18.png"/></fig><p>The moisture contents of the samples stored at levels of 76%, 85%, 98% and 100% RH are shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>. These results indicate that the volume having a moisture content of more than 0.19 was detected under the conditions in this study. However, it should be noted that the moisture-level threshold for detection obtained in this study may vary according to the MRI device and imaging parameters.</p></sec><sec id="s4_3"><title>4.3. Comparison of Permeation Depth Observation Methods</title><p>In <xref ref-type="fig" rid="fig5">Figure 5</xref>, the images of HCP made with WPC acquired via MRI, and those of the split surfaces obtained via water leakage detection are shown. In the split surface images, the dark-coloured areas indicate positions of water detection by the water leakage testing agent. Comparison of the results of both methods reveals a good agreement on water permeation depth that is independent of the method of drying. Note that the colours in the captured images differ because the measured positions of the samples differed, which thus yielded a difference in acquired signal strength; the colour difference is not an indication of a difference in water content. Therefore, these results indicate that, although MRI can provide a non-destructive measure of water permeation depth, the distribution of water content may be difficult to acquire because, as shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>, the signal strength varies according to position.</p></sec><sec id="s4_4"><title>4.4. Effects of Cement Type on MRI Signal</title><p>No signal was acquired from the HCP made with OPC while water was observed on its split surface (<xref ref-type="fig" rid="fig6">Figure 6</xref>). Moreover, the permeation depth of HCP made with OPC was lesser than that of HCP made with WPC. This is likely due to the magnetic components in OPC inhibiting the signal such that no water was detected using the measurement conditions in this study [<xref ref-type="bibr" rid="scirp.78463-ref8">8</xref>] . <xref ref-type="fig" rid="fig7">Figure 7</xref> illustrates the pore structures of HCP specimens comprising WPC and OPC that were dried under conditions of 40˚C and 10% RH for 2 weeks. HCP made with OPC exhibited a denser pore structure as compared to HPC made with WPC; this difference in porosity is suggested to be the cause of differing permeation depths.</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Water content in cement paste as a function of RH</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x19.png"/></fig><fig-group id="fig5"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Comparison of MRI images of HCP made with WPC and splitting surface as obtained via a water detector. (a) Dried at 20˚C for 1 month; (b) Dried at 20˚C for 2 weeks.</title></caption><fig id ="fig5_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x20.png"/></fig></fig-group><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Split surface of HCP made with OPC</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x21.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Pore size distribution in HCP</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x22.png"/></fig></sec><sec id="s4_5"><title>4.5. Effects of Aggregate Type</title><p>We have not provided the captured image of concrete with LWA because no signal was acquired. The acquired images of concrete with LSA at age 48 h are shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>. The seal-cured specimen exhibits a stronger signal than that cured under conditions of 20˚C and 60% RH. As these two specimens were identically positioned, the difference in signal intensity is directly proportional to the difference in water content; this can be confirmed by observing <xref ref-type="fig" rid="fig8">Figure 8</xref>(c), which shows that water was not detected in the sample dried at 105˚C.</p><p><xref ref-type="fig" rid="fig9">Figure 9</xref> shows the images of the concrete samples with LSA after having been soaked in water. It can be seen that water permeates deeper within the specimen cured at 20˚C in 60% RH than in the seal-cured specimen, while the specimen dried at 105˚C was found to have the greatest depth of water permeation. The water permeation profile was observed to be convex, deeper at the centre and shallower along the sides. This convex-shaped water front is presumed to be attributed to the drying of the side of the specimens, because, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>0, the specimens were soaked in water in a room maintained at a temperature of 20˚C and 40% RH. This result indicates that, in water permeation or water absorption test, the sides of the sample must be covered to prevent evaporation of the permeated water through the sides of the sample, thereby affecting the water permeation behaviour and causing it to differ from that observed in an actual concrete member.</p><fig-group id="fig8"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Images of HC with LSA; age: 48 h. (a) Seal-cured; (b) 20˚C 60% RH; (c) 105˚C.</title></caption><fig id ="fig8_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x23.png"/></fig></fig-group><fig-group id="fig9"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Images of HC with LSA after being soaked in water. (a) Seal-cured; (b) 20˚C 60% RH; (c) 105˚C.</title></caption><fig id ="fig9_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x24.png"/></fig></fig-group><fig id="fig10"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Schematic of water permeation and evaporation in an open-air container</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-1880835x25.png"/></fig></sec></sec><sec id="s5"><title>5. Conclusions</title><p>Non-destructive imaging of water in cementitious material was performed by implementing MRI; the following results were obtained according to the conditions and parameters used in this study.</p><p>- T<sub>1</sub> and<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-1880835x26.png" xlink:type="simple"/></inline-formula>, which yielded the relaxation curves for the signal acquired from HCP with WPC, were determined as 6.88 and 0.26 ms, respectively.</p><p>- The water permeation through HCP comprising WPC was detected via MRI. The resulting permeation depths as measured via MRI and a water leakage testing agent showing surface splitting demonstrated good agreement.</p><p>- In this study, HCP, which has a moisture content of more than 0.19, was detected via MRI.</p><p>- MRI was able to image the moisture loss and water permeation through concrete with LSA, but not in concrete with LWA.</p><p>The water permeation depth in concrete with LSA was detected via MRI. The permeation depth increased as the concrete dried, yielding a convex-shaped water front, which is indicative of evaporation of permeated water through the sides of the specimen.</p></sec><sec id="s6"><title>Acknowledgements</title><p>The authors would like to thank Dr. Hironori Nakatani at the Center for Evolutionary Cognitive Sciences at the University of Tokyo and Mr. Katsutoshi Murata at Siemens Healthineers Japan for setting the protocol for MRI. The lime stone aggregate was provided by Sumitomo Osaka Cement. This study was supported by a research grant from the Japan Concrete Institute.</p></sec><sec id="s7"><title>Cite this paper</title><p>Sakai, Y., Yokoyama, Y. and Kishi, T. (2017) Non-Destructive Imaging of Water Permeation through Cementitious Materials Using MRI. Open Journal of Civil Engineering, 7, 378-388. https://doi.org/10.4236/ojce.2017.73026</p></sec></body><back><ref-list><title>References</title><ref id="scirp.78463-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Claisse, P., Elsayad, H. and Ganjian, E. (2009) Water Vapor and Liquid Permeability Measurements in Cementitious Samples. Advances in Cement Research, 21, 83-89. 
https://doi.org/10.1680/adcr.8.00046</mixed-citation></ref><ref id="scirp.78463-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, S.P. and Zong, L. (2014) Evaluation of Relationship between Water Absorption and Durability Ofconcrete Materials. Advances in Materials Science and Engineering, 2014, Article ID: 650373. https://doi.org/10.1155/2014/650373</mixed-citation></ref><ref id="scirp.78463-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Akita, H., Fujiwara, T. and Ozaka, Y. (1996) A Practical Procedure for the Analysis of Moisture Transfer within Concrete Due to Drying. Magazine of Concrete Research, 48, 129-137.</mixed-citation></ref><ref id="scirp.78463-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, X. and Zhao, H. (2015) Characterization of Moisture Diffusion in cured Concrete Slabs at Early Ages. Advances in Materials Science and Engineering, 2015, Article ID: 154394. https://doi.org/10.1155/2015/154394</mixed-citation></ref><ref id="scirp.78463-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Ueda, H. and Suzuki, H. (2016) Water Penetrability into Concrete Surface and Interface between Concrete and Repair Materials. Quarterly Report of RTRI, 57, 36-41. https://doi.org/10.2219/rtriqr.57.1_36</mixed-citation></ref><ref id="scirp.78463-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Justnes, H., Bryhn, K. and Rosvold, G.O. (1994) Neutron Radiography: An Excellent Method of Measuring Water Penetration and Moisture Distribution in Cementitious Materials. Advances in Cement Research, 6, 67-72. 
https://doi.org/10.1680/adcr.1994.6.22.67</mixed-citation></ref><ref id="scirp.78463-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Pleinert, H., Sadouki, H. and Wittmann, F.H. (1998) Determination of Moisture Distributions in Porous Building Materials by Neutron Transmission Analysis. Materials and Structures, 31, 218-224. https://doi.org/10.1007/BF02480418</mixed-citation></ref><ref id="scirp.78463-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Marfisi, E., Burgoyne, C.J., Amin, M.H.G. and Hall, L.D. (2005) The Use of MRI to Observe the Structure of Concrete. Magazine of Concrete Research, 57, 101-109. 
https://doi.org/10.1680/macr.2005.57.2.101</mixed-citation></ref><ref id="scirp.78463-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Marfisi, E., Burgoyne, C.J., Amin, M.H.G. and Hall, L.D. (2005) The Use of MRI to Observe Fractures in Concrete. Magazine of Concrete Research, 57, 113-123. 
https://doi.org/10.1680/macr.2005.57.2.111</mixed-citation></ref><ref id="scirp.78463-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Kaufmann, J., Studer, W., Link, J. and Schenker, K. (1997) Study of Water Suction of Concrete with Magnetic Resonance Imaging Methods. Magazine of Concrete Research, 49, 157-165. https://doi.org/10.1680/macr.1997.49.180.157</mixed-citation></ref><ref id="scirp.78463-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Hashemi, R.H., Bradley, W.G. and Lisanti, C.J. (2010) MRI: The Basics. Lippincott Williams &amp; Wilkins, Philadelphia.</mixed-citation></ref><ref id="scirp.78463-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Haynes, H. and Holmes, W.M. (2013) The Emerging Use of Magnetic Resonance Imaging (MRI) for 3D Analysis of Sediment Structures and Internal Flow Processes. British Society for Geomorphology, London.</mixed-citation></ref></ref-list></back></article>