<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">GEP</journal-id><journal-title-group><journal-title>Journal of Geoscience and Environment Protection</journal-title></journal-title-group><issn pub-type="epub">2327-4336</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/gep.2017.58016</article-id><article-id pub-id-type="publisher-id">GEP-78204</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Earth&amp;Environmental Sciences</subject></subj-group></article-categories><title-group><article-title>
 
 
  Physico-Chemical Characterization of Industrial Liquid Discharges of Soap Factories in Abidjan, C&#244;te D’Ivoire
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jean</surname><given-names>Missa Ehouman</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Bernard</surname><given-names>O. Yapo</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Agness</surname><given-names>Essoh Jean Eudes Y. Gnagne</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nahossé</surname><given-names>Ziao</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Laboratory of Thermodynamics and Physical Chemistry of the Environment, (UFR-SFA), UNA, Abidjan, C&amp;amp;#244te d’Ivoire</addr-line></aff><aff id="aff2"><addr-line>The Central Environment Laboratory of the Ivorian Anti-pollution Center, Abidjan, C&amp;amp;#244te d’Ivoire</addr-line></aff><aff id="aff3"><addr-line>Laboratory of Environmental Sciences, (UFR-SGE), UNA, Abidjan, C&amp;amp;#244te d’Ivoire</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>nahosse_ziao@yahoo.fr(NZ)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>18</day><month>07</month><year>2017</year></pub-date><volume>05</volume><issue>08</issue><fpage>198</fpage><lpage>210</lpage><history><date date-type="received"><day>June</day>	<month>21,</month>	<year>2017</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>August</month>	<year>4,</year>	</date><date date-type="accepted"><day>August</day>	<month>7,</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p><html>
 <head></head>
 
  This work deals with the efficient management of industrial liquid discharges from soap factories (ILDS) in the region of Abidjan. The aim of this work is to evaluate the physico-chemical quality of these discharges as well as the different types of pollution generated. Seventeen (17) industrial soap sources were studied through fourteen (14) global pollution parameters (T, pH, electrical conductivity EC, redox potential EH, suspended matter SM, COD, BOD5, biodegradability factor BF, 
  <img src="Edit_3a23ce5e-80ce-4610-837c-8b5d16ebd757.bmp" alt="" />, 
  <img src="Edit_1a93464c-5966-4de0-a121-176c54db88da.bmp" alt="" />, 
  <img src="Edit_5204f6c5-6a95-4bd3-ac92-a1c5e5ee03b5.bmp" alt="" />, 
  <img src="Edit_602e0edd-6acb-489e-8788-0b260bfad671.bmp" alt="" />, total iron and 
  <img src="Edit_8b46ae3e-8251-4311-9b37-6d280ca5ecf5.bmp" alt="" />). A liquid waste collection campaign was done during six weeks from February to March 2016, corresponding to a period of intensive activity of these industries. The samples were analyzed according to the norms of the French Standardization Agency (AFNOR). Results were compared with the Ivorian guide values recommended by the Classified Installations Inspection Service (CIIS). Principal Component Analysis (PCA) is allowed to evaluate the pollution induced by these factories’ rejection. In addition, Ascending Hierarchical Classification (AHC) method leads to classify soap factories into three groups according to the physico-chemical quality of their releases. Moreover, the estimation of the biodegradability factor is permitted to know the state of the biodegradability of these effluents.
 
</html></p></abstract><kwd-group><kwd>Biodegradability</kwd><kwd> ILDS</kwd><kwd> Pollution</kwd><kwd> Soap Industries</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Abidjan City gathers up to 85% of industries settled in C&#244;te d’Ivoire, because of its lagoon and sea assets. These industries are localized in various areas of the different industrial zones [<xref ref-type="bibr" rid="scirp.78204-ref1">1</xref>] . Despite Ivorian government’s efforts to protect the environment, very few industries do follow its recommendations [<xref ref-type="bibr" rid="scirp.78204-ref2">2</xref>] . The use of water in the production process generates a huge volume of rejected liquid heavily loaded with oxidable materials [<xref ref-type="bibr" rid="scirp.78204-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.78204-ref4">4</xref>] . The increase of soap industries is due to the increase of human beings needs in term of soap, detergent and cosmetic. And this soap factories growth participates to this ecological disaster. These soap factories, like the other industries, are mainly concentrated in the area of Abidjan. They contribute to the production of enormous volume of effluents in Abidjan area. The characterization of ILDS in C&#244;te d’Ivoire remains less established to date. This fact confers a certain scientific interest on these discharges. That is why more complete physicochemical characterization constituted the first step to be taken into account in order to estimate the level of pollution of this type of industrial waste.</p></sec><sec id="s2"><title>2. Experimentation Method</title><sec id="s2_1"><title>2.1. Area of Study and Location of Soap Factories</title><p>The area of Abidjan has a fluvial network of 89.81 km<sup>2</sup> of lagoon, which is equivalent to 16% of its area [<xref ref-type="bibr" rid="scirp.78204-ref5">5</xref>] with an estimated population of 4,693,912 [<xref ref-type="bibr" rid="scirp.78204-ref6">6</xref>] . The seventeen soap factories targeted are those which throw directly their rejection into the lagoon. The mapping of the studied area (<xref ref-type="fig" rid="fig1">Figure 1</xref>) shows the different industrial areas, the location of the studied soap factories and the river system of Abidjan’s town.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Mapping of the study area and location of soap factories</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/16-2170469x7.png"/></fig></sec><sec id="s2_2"><title>2.2. Sampling Method</title><p>Samples have been collected in the seventeen factories at the level of the outlet before rejection of soap factories in polyethylene and put in glass bottles (for total iron parameter). Bottles are washed with distilled water before collecting process. Then collected samples are labelled, conserved at temperature of 4˚C and kept away from light in ice-box. Finally samples are analyzed the same day as soon as possible in order to avoid any bacterial activity. This sampling has been done during six (6) weeks from February to March, 2016. This period corresponds to the highest level of the production of soap factories.</p></sec><sec id="s2_3"><title>2.3. Analysis Method</title><p>Physical parameters such as temperature, pH, redox potential and electrical conductivity were measured by electrometry in situ using a HACH HQ 40 D multiparameter probe. Ammonium, nitrite, nitrate, sulphate, ortho-phosphate, chemical oxygen demand (COD), and the total iron rate were measured through molecular absorption using a HACH/DR 6000 spectrometer. The Biochemical Oxygen Demand (BOD<sub>5</sub>) was measured by oximetry using an Oxitop&#174; WTW oximeter. Finally, the analysis of suspended matter (SM) was carried out through filtration/gravimetry with the WHATMAN filters. All these analyses were done according to the methods of the French Standardization Agency AFNOR [<xref ref-type="bibr" rid="scirp.78204-ref7">7</xref>] . The data collected were treated using statistical approaches such as the correlation coefficient, Principal Component Analysis (PCA) and Ascending Hierarchical Classification (AHC) [<xref ref-type="bibr" rid="scirp.78204-ref8">8</xref>] . Statistical treatments were carried out using the Statistica 7.1 software.</p></sec></sec><sec id="s3"><title>3. Results and Discussions</title><sec id="s3_1"><title>3.1. Physical Characterization of Industrial Liquid Discharges of Soap Factories (ILDS)</title><p><xref ref-type="table" rid="table1">Table 1</xref> presents the results of the characterization of the physical parameters of ILDS. Samples P16 and Y6 show the extreme temperature values of 25.4˚C and 39.0˚C respectively. All the measured values are lower than 40˚C, thus respecting CIIS recommended temperature in the case of discharge of effluents towards environment [<xref ref-type="bibr" rid="scirp.78204-ref9">9</xref>] . The highest and lowest pH values have been found in the soap effluent K13 and Y2, respectively. The high alkaline pH values recorded in 29.00% of the soap factories studied can be explained by the different activities related to the use of alkaline agents (caustic soda and potash) in soap formulation.</p><p>In fact, this essential raw material impacts, at several levels, the system of detergent’s products formulation. First, the fatty acids are saponified by caustic soda or potash. In addition the lye (soda solution) is used for the operation of the hypo-lye. The rejections resulting from these operations, coupled with washing water of the soap, constitute effluents heavily loaded with hydroxide ions, which changes the pH of these discharges into alkaline. For soap factories with medium pH discharges, two explanations can be provided: The first is that</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Physical parameter values</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Stations</th><th align="center" valign="middle" >T (˚C)</th><th align="center" valign="middle" >pH</th><th align="center" valign="middle" >EC (&#181;S/cm)</th><th align="center" valign="middle" >E<sub>H</sub> (mV)</th><th align="center" valign="middle" >SM (mg/L)</th></tr></thead><tr><td align="center" valign="middle" >Y1</td><td align="center" valign="middle" >29.9</td><td align="center" valign="middle" >7.32</td><td align="center" valign="middle" >441</td><td align="center" valign="middle" >−16.7</td><td align="center" valign="middle" >2060</td></tr><tr><td align="center" valign="middle" >Y2</td><td align="center" valign="middle" >31.1</td><td align="center" valign="middle" >5.13</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >115.1</td><td align="center" valign="middle" >214</td></tr><tr><td align="center" valign="middle" >Y3</td><td align="center" valign="middle" >29.7</td><td align="center" valign="middle" >7.16</td><td align="center" valign="middle" >741</td><td align="center" valign="middle" >−6.9</td><td align="center" valign="middle" >2040</td></tr><tr><td align="center" valign="middle" >Y4</td><td align="center" valign="middle" >30.4</td><td align="center" valign="middle" >12.37</td><td align="center" valign="middle" >17270</td><td align="center" valign="middle" >−319.4</td><td align="center" valign="middle" >25</td></tr><tr><td align="center" valign="middle" >Y5</td><td align="center" valign="middle" >30.5</td><td align="center" valign="middle" >6.62</td><td align="center" valign="middle" >495</td><td align="center" valign="middle" >24.5</td><td align="center" valign="middle" >26</td></tr><tr><td align="center" valign="middle" >Y6</td><td align="center" valign="middle" >39</td><td align="center" valign="middle" >7.75</td><td align="center" valign="middle" >682</td><td align="center" valign="middle" >−43.6</td><td align="center" valign="middle" >51125</td></tr><tr><td align="center" valign="middle" >Y7</td><td align="center" valign="middle" >28.3</td><td align="center" valign="middle" >7.42</td><td align="center" valign="middle" >1992</td><td align="center" valign="middle" >23.7</td><td align="center" valign="middle" >6200</td></tr><tr><td align="center" valign="middle" >Y8</td><td align="center" valign="middle" >27.5</td><td align="center" valign="middle" >10.31</td><td align="center" valign="middle" >1737</td><td align="center" valign="middle" >−193.9</td><td align="center" valign="middle" >220</td></tr><tr><td align="center" valign="middle" >Y9</td><td align="center" valign="middle" >28.2</td><td align="center" valign="middle" >12.58</td><td align="center" valign="middle" >14640</td><td align="center" valign="middle" >−330.6</td><td align="center" valign="middle" >1284</td></tr><tr><td align="center" valign="middle" >Y10</td><td align="center" valign="middle" >29.7</td><td align="center" valign="middle" >6.38</td><td align="center" valign="middle" >76.4</td><td align="center" valign="middle" >21.4</td><td align="center" valign="middle" >4</td></tr><tr><td align="center" valign="middle" >K11</td><td align="center" valign="middle" >31.5</td><td align="center" valign="middle" >9.74</td><td align="center" valign="middle" >957</td><td align="center" valign="middle" >−162.6</td><td align="center" valign="middle" >260</td></tr><tr><td align="center" valign="middle" >K12</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >5.27</td><td align="center" valign="middle" >645</td><td align="center" valign="middle" >106</td><td align="center" valign="middle" >2365</td></tr><tr><td align="center" valign="middle" >K13</td><td align="center" valign="middle" >32.1</td><td align="center" valign="middle" >13.47</td><td align="center" valign="middle" >138.4</td><td align="center" valign="middle" >−387.6</td><td align="center" valign="middle" >1570</td></tr><tr><td align="center" valign="middle" >P14</td><td align="center" valign="middle" >30.1</td><td align="center" valign="middle" >6.61</td><td align="center" valign="middle" >599</td><td align="center" valign="middle" >26.3</td><td align="center" valign="middle" >10384</td></tr><tr><td align="center" valign="middle" >P15</td><td align="center" valign="middle" >28</td><td align="center" valign="middle" >7.84</td><td align="center" valign="middle" >463</td><td align="center" valign="middle" >−47.5</td><td align="center" valign="middle" >80</td></tr><tr><td align="center" valign="middle" >P16</td><td align="center" valign="middle" >25.4</td><td align="center" valign="middle" >8.10</td><td align="center" valign="middle" >63</td><td align="center" valign="middle" >82</td><td align="center" valign="middle" >6.8</td></tr><tr><td align="center" valign="middle" >A17</td><td align="center" valign="middle" >32.3</td><td align="center" valign="middle" >6.12</td><td align="center" valign="middle" >570</td><td align="center" valign="middle" >55.5</td><td align="center" valign="middle" >588</td></tr><tr><td align="center" valign="middle" >VG*</td><td align="center" valign="middle" >&lt;40</td><td align="center" valign="middle" >5.5-9.5</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >150</td></tr></tbody></table></table-wrap><p>VG*: Guide values referring to the lowest daily flow rates 01164 / MINEEF / CIAPOL / CIIS of 04 November 2008 [<xref ref-type="bibr" rid="scirp.78204-ref9">9</xref>] .</p><p>these soap-making plants do not carry out saponification in their premises. They import soap paste bells for their productions. The second explanation comes from the fact that soap-making plants with weakly alkaline or neutral waste, the saponification is made with triethanolamine, which is a weak base organic alkaline agent. It should be noted that all these soaps produced by factories are used as toilet soaps with low pH value. In other way, it has been shown that 12.00% of the studied soap factories rejected water discharge with acid pH. These soap-making factories produce others commodities such as water of cleaning (bleach) and cosmetics products.</p><p>Analysis of the Electrical Conductivity (EC) of soap effluents reveals a fluctuation of the values of this parameter. The high values of this parameter are observed in effluents from the soap mills (Y4, Y9) in Yopougon area. The Y4 soap effluent recorded the highest value (17,270 μS/cm). The lowest value (40 μS/cm) was observed in the Y2 soap rejection (<xref ref-type="table" rid="table1">Table 1</xref>). Correlation’s analysis between physico-chemical parameters (<xref ref-type="table" rid="table2">Table 2</xref>) reveals a strong positive correlation of conductivity with nitrates (0.90), ortho phosphates (0.69) and, to a lesser extent, with nitrites (0.62). This high mineralization is therefore due to the oxidation of these nutrients in the soap effluent. The oxidation-reduction potential value ranges from −387.6 mV (soap-making K13) to 115.1 mV (soap-making Y2) (<xref ref-type="table" rid="table1">Table 1</xref>). 76% of these releases have a reducing character with redox</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Correlation matrix of the physicochemical parameters of all the ILDS</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Variables</th><th align="center" valign="middle" >T</th><th align="center" valign="middle" >pH</th><th align="center" valign="middle" >EC</th><th align="center" valign="middle" >E<sub>H</sub></th><th align="center" valign="middle" >SM</th><th align="center" valign="middle" >COD</th><th align="center" valign="middle" >BOD<sub>5</sub></th><th align="center" valign="middle" >BF</th><th align="center" valign="middle" >T iron</th><th align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x8.png" xlink:type="simple"/></inline-formula></th><th align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x9.png" xlink:type="simple"/></inline-formula></th><th align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x10.png" xlink:type="simple"/></inline-formula></th><th align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x11.png" xlink:type="simple"/></inline-formula></th><th align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x12.png" xlink:type="simple"/></inline-formula></th></tr></thead><tr><td align="center" valign="middle" >T</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >pH</td><td align="center" valign="middle" >−0.07</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >EC</td><td align="center" valign="middle" >−0.12</td><td align="center" valign="middle" >0.63</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >E<sub>H</sub></td><td align="center" valign="middle" >−0.04</td><td align="center" valign="middle" >−0.97</td><td align="center" valign="middle" >−0.63</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >SM</td><td align="center" valign="middle" >0.77</td><td align="center" valign="middle" >−0.09</td><td align="center" valign="middle" >−0.11</td><td align="center" valign="middle" >0.07</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >COD</td><td align="center" valign="middle" >0.31</td><td align="center" valign="middle" >0.09</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >−0.13</td><td align="center" valign="middle" >0.41</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >BOD<sub>5</sub></td><td align="center" valign="middle" >0.81</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >−0.04</td><td align="center" valign="middle" >−0.09</td><td align="center" valign="middle" >0.93</td><td align="center" valign="middle" >0.61</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >BF</td><td align="center" valign="middle" >−0.14</td><td align="center" valign="middle" >0.11</td><td align="center" valign="middle" >0.16</td><td align="center" valign="middle" >−0.15</td><td align="center" valign="middle" >−0.13</td><td align="center" valign="middle" >0.79</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" >T iron</td><td align="center" valign="middle" >−0.13</td><td align="center" valign="middle" >0.14</td><td align="center" valign="middle" >−0.05</td><td align="center" valign="middle" >−0.17</td><td align="center" valign="middle" >−0.09</td><td align="center" valign="middle" >0.65</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >0.81</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x13.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >−0.04</td><td align="center" valign="middle" >0.56</td><td align="center" valign="middle" >0.90</td><td align="center" valign="middle" >−0.57</td><td align="center" valign="middle" >−0.13</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >−0.04</td><td align="center" valign="middle" >0.17</td><td align="center" valign="middle" >−0.08</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x14.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >0.01</td><td align="center" valign="middle" >0.26</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle" >−0.28</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >0.16</td><td align="center" valign="middle" >0.12</td><td align="center" valign="middle" >0.18</td><td align="center" valign="middle" >0.12</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x15.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >0.50</td><td align="center" valign="middle" >0.41</td><td align="center" valign="middle" >−0.10</td><td align="center" valign="middle" >−0.46</td><td align="center" valign="middle" >0.174</td><td align="center" valign="middle" >−0.05</td><td align="center" valign="middle" >0.26</td><td align="center" valign="middle" >−0.23</td><td align="center" valign="middle" >−0.03</td><td align="center" valign="middle" >−0.05</td><td align="center" valign="middle" >−0.11</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x16.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >−0.24</td><td align="center" valign="middle" >0.69</td><td align="center" valign="middle" >0.69</td><td align="center" valign="middle" >−0.70</td><td align="center" valign="middle" >−0.20</td><td align="center" valign="middle" >0.44</td><td align="center" valign="middle" >−0.03</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle" >0.59</td><td align="center" valign="middle" >0.53</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >1.00</td><td align="center" valign="middle" ></td></tr><tr><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x17.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >−0.27</td><td align="center" valign="middle" >0.15</td><td align="center" valign="middle" >−0.00</td><td align="center" valign="middle" >−0.15</td><td align="center" valign="middle" >−0.11</td><td align="center" valign="middle" >0.70</td><td align="center" valign="middle" >−0.00</td><td align="center" valign="middle" >0.83</td><td align="center" valign="middle" >0.87</td><td align="center" valign="middle" >−0.02</td><td align="center" valign="middle" >0.14</td><td align="center" valign="middle" >−0.19</td><td align="center" valign="middle" >0.60</td><td align="center" valign="middle" >1.00</td></tr></tbody></table></table-wrap><p>In bold, significant values at the alpha threshold = 0.050.</p><p>potentials negative or less than 40.0 mV [<xref ref-type="bibr" rid="scirp.78204-ref10">10</xref>] . These reductive soap discharges contain mainly aldehydes, organic compounds exhibiting reducing properties, resulting from the oxidation of compounds such as glycerols, polyphenols and polyalcohols used for the formulation of detergents and cosmetics [<xref ref-type="bibr" rid="scirp.78204-ref11">11</xref>] . The oxidation of the alcohol functions into aldehydes and the different oxidation-reduction reactions which result, use the oxygen of the receiving environment. Furthermore, the negative correlation of the oxidation-reduction potential with nitrates (−0.57), ortho-phosphates (−0.70) and conductivity (−0.63) explains the reverse evolution of these parameters with the redox potential. The reducing properties of soap effluents allow the oxidation of nitrates and ortho-phosphates. The mineralization is due to this oxidation. These oxidation reactions reduce oxygen concentrations in the receiving environment, so that affects aquatic life [<xref ref-type="bibr" rid="scirp.78204-ref12">12</xref>] . The analyzed concentrations of Suspended Matter (SM) are irregularly distributed (<xref ref-type="table" rid="table1">Table 1</xref>). Some soap factories have high SM concentrations that exceed 4 to 341 times the guide value (150 mg/L). The very high SM content of these discharges is due to mineral and organic raw materials used in the formulation of their products. These industries, specialized in the formulation of cosmetic products according to our investigation, use excipients and active ingredients (fatty acids, glycerol, surfactants, polyalcohols etc.) as raw materials. The strong positive correlation of suspended matter with BOD<sub>5</sub> (0.93) (<xref ref-type="table" rid="table2">Table 2</xref>) confirms the biodegradable organic origin of these SM in liquid soap discharges from soap industries. Moreover, this parameter is positively correlated with the temperature (0.81) (<xref ref-type="table" rid="table2">Table 2</xref>).</p><p>The temperature favors the degradation of suspended organic matter in soap effluents. That damages the different receiving environments. Indeed, SM in a lagoon environment reduce the penetration of light into the water, consequently reduce the photosynthesis of phytoplankton under water, and dissolve oxygen in the aquatic environment. This causes faunal and aquatic floristic mortality by asphyxia [<xref ref-type="bibr" rid="scirp.78204-ref12">12</xref>] . In addition, SM conveys various chemical elements into the aquatic environment. The high concentrations of this parameter, generated by soap discharges, can be seen as a factor of pollution of the Ebri&#233; lagoon [<xref ref-type="bibr" rid="scirp.78204-ref13">13</xref>] .</p></sec><sec id="s3_2"><title>3.2. Chemical Characterization of Industrial Liquid Discharges of Soap Factories (ILDS)</title><p>The analysis’ results of chemical parameters are recorded in <xref ref-type="table" rid="table3">Table 3</xref> below.</p><p>The analyzed ammonium concentrations of the ILDS range from 1.40 mg/L to 75.80 mg/L The highest value corresponds to the soap factory K11 (<xref ref-type="table" rid="table3">Table 3</xref>). In general, these soap factories use nitrogenous compound such as anionic surfactants (ammonium dodecyl sulphate), cationic surfactants such as bactericides (cetyltrimethylammonium bromide) and azo derivatives dye (Naphtol Blue Black: NBB) as the colorant of detergents [<xref ref-type="bibr" rid="scirp.78204-ref14">14</xref>] . The ammonium ions come from the degradation of these azo dyes. This degradation generates <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x18.png" xlink:type="simple"/></inline-formula> cations due to the conversion of the nitrogen of the azo bond and the thriazine cycle into ammoniums [<xref ref-type="bibr" rid="scirp.78204-ref14">14</xref>] . The degradation of cationic surfactants such as cetyltrimethylammonium bromide also justifies the presence of these ammonium ions. The nitrites concentrations have a minimum of 0.003 mg/L and a maximum of</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Concentrations of the chemical parameters analyzed in ILDS</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Stations</th><th align="center" valign="middle"  colspan="9"  >Chemical parameter (mg/L)</th></tr></thead><tr><td align="center" valign="middle" >COD</td><td align="center" valign="middle" >BOD<sub>5</sub></td><td align="center" valign="middle" >BF</td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x19.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x20.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x21.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x22.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" ><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x23.png" xlink:type="simple"/></inline-formula></td><td align="center" valign="middle" >T iron</td></tr><tr><td align="center" valign="middle" >Y1</td><td align="center" valign="middle" >5760</td><td align="center" valign="middle" >900</td><td align="center" valign="middle" >6.4</td><td align="center" valign="middle" >21.8</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" >0.7</td><td align="center" valign="middle" >22</td><td align="center" valign="middle" >0.5</td></tr><tr><td align="center" valign="middle" >Y2</td><td align="center" valign="middle" >34,000</td><td align="center" valign="middle" >1700</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >1.3</td><td align="center" valign="middle" >0.006</td><td align="center" valign="middle" >8.9</td><td align="center" valign="middle" >0.1</td><td align="center" valign="middle" >500</td><td align="center" valign="middle" >3.1</td></tr><tr><td align="center" valign="middle" >Y3</td><td align="center" valign="middle" >3700</td><td align="center" valign="middle" >800</td><td align="center" valign="middle" >4.6</td><td align="center" valign="middle" >21</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >17.2</td><td align="center" valign="middle" >13.2</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >6.2</td></tr><tr><td align="center" valign="middle" >Y4</td><td align="center" valign="middle" >13,800</td><td align="center" valign="middle" >1000</td><td align="center" valign="middle" >13.8</td><td align="center" valign="middle" >350</td><td align="center" valign="middle" >1.4</td><td align="center" valign="middle" >14.9</td><td align="center" valign="middle" >47.7</td><td align="center" valign="middle" >230</td><td align="center" valign="middle" >1.5</td></tr><tr><td align="center" valign="middle" >Y5</td><td align="center" valign="middle" >4030</td><td align="center" valign="middle" >750</td><td align="center" valign="middle" >5.4</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >0.012</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >36</td><td align="center" valign="middle" >0.13</td></tr><tr><td align="center" valign="middle" >Y6</td><td align="center" valign="middle" >37,900</td><td align="center" valign="middle" >8000</td><td align="center" valign="middle" >4.7</td><td align="center" valign="middle" >3</td><td align="center" valign="middle" >0.51</td><td align="center" valign="middle" >34.4</td><td align="center" valign="middle" >0.6</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >2.4</td></tr><tr><td align="center" valign="middle" >Y7</td><td align="center" valign="middle" >580</td><td align="center" valign="middle" >180</td><td align="center" valign="middle" >3.2</td><td align="center" valign="middle" >1.7</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >8.5</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >700</td><td align="center" valign="middle" >0.5</td></tr><tr><td align="center" valign="middle" >Y8</td><td align="center" valign="middle" >51,300</td><td align="center" valign="middle" >1500</td><td align="center" valign="middle" >34.2</td><td align="center" valign="middle" >14.2</td><td align="center" valign="middle" >0.6</td><td align="center" valign="middle" >8.27</td><td align="center" valign="middle" >62.5</td><td align="center" valign="middle" >2300</td><td align="center" valign="middle" >36.9</td></tr><tr><td align="center" valign="middle" >Y9</td><td align="center" valign="middle" >9170</td><td align="center" valign="middle" >1100</td><td align="center" valign="middle" >8.3</td><td align="center" valign="middle" >112</td><td align="center" valign="middle" >0.8</td><td align="center" valign="middle" >12.5</td><td align="center" valign="middle" >48.2</td><td align="center" valign="middle" >3.4</td><td align="center" valign="middle" >2.4</td></tr><tr><td align="center" valign="middle" >Y10</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >11.25</td><td align="center" valign="middle" >1.3</td><td align="center" valign="middle" >1.1</td><td align="center" valign="middle" >0.026</td><td align="center" valign="middle" >7.41</td><td align="center" valign="middle" >0.6</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >0.3</td></tr><tr><td align="center" valign="middle" >K11</td><td align="center" valign="middle" >3800</td><td align="center" valign="middle" >850</td><td align="center" valign="middle" >4.5</td><td align="center" valign="middle" >12.1</td><td align="center" valign="middle" >0.3</td><td align="center" valign="middle" >75.8</td><td align="center" valign="middle" >22.8</td><td align="center" valign="middle" >90</td><td align="center" valign="middle" >5.5</td></tr><tr><td align="center" valign="middle" >K12</td><td align="center" valign="middle" >7340</td><td align="center" valign="middle" >1000</td><td align="center" valign="middle" >7.3</td><td align="center" valign="middle" >11.2</td><td align="center" valign="middle" >1.33</td><td align="center" valign="middle" >6.11</td><td align="center" valign="middle" >0.4</td><td align="center" valign="middle" >16</td><td align="center" valign="middle" >1.2</td></tr><tr><td align="center" valign="middle" >K13</td><td align="center" valign="middle" >5510</td><td align="center" valign="middle" >1500</td><td align="center" valign="middle" >3.7</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >54</td><td align="center" valign="middle" >5.7</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >0.6</td></tr><tr><td align="center" valign="middle" >P14</td><td align="center" valign="middle" >8320</td><td align="center" valign="middle" >700</td><td align="center" valign="middle" >11.9</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >10.8</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >1.8</td></tr><tr><td align="center" valign="middle" >P15</td><td align="center" valign="middle" >3400</td><td align="center" valign="middle" >800</td><td align="center" valign="middle" >4.3</td><td align="center" valign="middle" >4</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >0.1</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >0.015</td></tr><tr><td align="center" valign="middle" >P16</td><td align="center" valign="middle" >119</td><td align="center" valign="middle" >42</td><td align="center" valign="middle" >2.8</td><td align="center" valign="middle" >0.024</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >1.4</td><td align="center" valign="middle" >2.28</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >0.015</td></tr><tr><td align="center" valign="middle" >A17</td><td align="center" valign="middle" >2690</td><td align="center" valign="middle" >280</td><td align="center" valign="middle" >9.6</td><td align="center" valign="middle" >0.002</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >21.7</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >12</td></tr><tr><td align="center" valign="middle" >VG*</td><td align="center" valign="middle" >500</td><td align="center" valign="middle" >150</td><td align="center" valign="middle" ></td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >5</td></tr></tbody></table></table-wrap><p>1.400 mg/L (<xref ref-type="table" rid="table3">Table 3</xref>). It should be noted that 29.41% of the soap mills (Y3, Y4, Y8, Y9 and K12) have nitrites concentrations above the recommended guide values of 0.500 mg/L. These soap factories use nitrated and nitrosated dyes (X-C<sub>6</sub>H<sub>5</sub>-NO<sub>2</sub>) which generate nitrates as a result of their degradation. As for nitrates, the contents fluctuate between 0.002 mg/L and 350.000 mg/L. Soap factories Y9 and Y4 show similarities in terms of nitrates with very high contents (<xref ref-type="table" rid="table3">Table 3</xref>). The presence of nitrates is due, in part, to the use of nitrogenous compound in the formulation of detergents and cosmetics. They are azo, nitrated and nitrosated dyes, nitrogen-containing surfactants, adjuvants such as nitrilotriacetic acid (NTA: C<sub>6</sub>H<sub>9</sub>NO<sub>6</sub>), ethylene diamine tetraacetic acid (EDTA: C<sub>10</sub>H<sub>16</sub>N<sub>2</sub>O<sub>8</sub>), triethanolamine (C<sub>6</sub>H<sub>15</sub>NO<sub>3</sub>). These compounds release nitrate ions, ammonium and nitrite ions [<xref ref-type="bibr" rid="scirp.78204-ref15">15</xref>] . Ammonium and nitrite ions can be oxidized into nitrates. In the light of the analyses, it can be said that the soap effluents are relatively rich in nitrogenous nutrients. The quantities of ortho-phosphates vary from 0.100 mg/L to 62.500 mg/L (<xref ref-type="table" rid="table3">Table 3</xref>). Soap factories with concentrations of ortho-phosphates higher than 2 mg/L use raw materials rich in phosphorus elements as adjuvants or bleaching agents (sodium tripolyphosphates: Na<sub>5</sub>P<sub>3</sub>O<sub>10</sub>, sodium pyrophosphate: Na<sub>4</sub>P<sub>2</sub>O<sub>7</sub>, trisodium phosphate: Na<sub>3</sub>PO<sub>4</sub>) for the formulation of detergents and cosmetics, especially. These compounds containing the soluble inorganic phosphorus in solution are transformed into orthophosphates which come from the hydrolysis of phosphoric acid. Even in very small quantity, orthophosphates are harmful for the environment due to the fact that they are easily absorbed by the soil, polluting thereby well water and the ground-water sheet [<xref ref-type="bibr" rid="scirp.78204-ref16">16</xref>] . Based on the recorded values, all the soap factories are potential polluters in terms of orthophosphates. Despite its usefulness, phosphorus is forbidden in the formulation of detergent and cosmetic products [<xref ref-type="bibr" rid="scirp.78204-ref17">17</xref>] . In sum, soap discharges are rich in nutrients that can impact environment. Indeed, concentration of nitrogen ammoniacal (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x24.png" xlink:type="simple"/></inline-formula>) at about 1.2 mg/L in a hydro system, at pH 7.5˚C and 15˚C, is toxic for fish fauna [<xref ref-type="bibr" rid="scirp.78204-ref18">18</xref>] . In addition, nutrient concentrations can lead to an increase of algal blooms and consequently the appearance of eutrophication phenomena when the concentration of <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x25.png" xlink:type="simple"/></inline-formula> equals 0.03 mg/L and the concentration of phosphorus equals 0.01 mg/L [<xref ref-type="bibr" rid="scirp.78204-ref19">19</xref>] . The sulfate concentration contained in ILDS fluctuates between 1.5 mg/L and 2300 mg/L. Soap factory Y8 has the maximum concentration of sulphate ions (<xref ref-type="table" rid="table3">Table 3</xref>). The factories those rejections contain a lot of sulfate are specialized in the formulation of colored toilet soaps, cosmetics (shampoos, toothpaste, mouthwash products, etc.). These soap and cosmetics industries use anionic surfactants such as sodium dodecyl sulphate (SDS: C<sub>12</sub>H<sub>25</sub>SO<sub>4</sub>Na) in the formulation of their products, sulfonated surfactants, especially sodium dodecylbenzene sulphonate (DBS: C<sub>18</sub>H<sub>29</sub>SO<sub>3</sub>Na) and sulfated inorganic pigments or coloring agent, ferrous sulfate (FeSO<sub>4</sub>, 7H<sub>2</sub>O), zinc sulfate (ZnSO<sub>4</sub>) and organic sulfur dyes. These sulfate ions come essentially from both the dissolution of the sulfated salts and the oxidation of the sulfide groups of the aforementioned surfactants and dyes [<xref ref-type="bibr" rid="scirp.78204-ref20">20</xref>] . The total iron concentrations in the ILDS range from 0.015 mg/L to 36.900 mg/L (<xref ref-type="table" rid="table3">Table 3</xref>). The total iron concentrations for some soap factories (Y3, Y8 and A17) are 1.24 to 7 times higher than the guide value (5 mg/L). These soap factories therefore use raw materials rich in iron ions. These soap factories use colored pigments such as iron oxide (Fe(NH<sub>4</sub>COO)<sub>2</sub>), the complex salt (ferric ferrocyanide or Prussian blue) and ferrous sulphate (FeSO<sub>4</sub>, 7H<sub>2</sub>O) to color detergents and cosmetics. The iron ions in the liquid discharges of these soap mills therefore result from the dissolution of these inorganic dyes. Y8 soap effluent contains the highest concentration of sulfates and total iron. It mainly uses iron sulfate (FeSO<sub>4</sub>, 7H<sub>2</sub>O) as a colorant for the formulation of their mostly cosmetic products. That can be explained by the strong positive correlation of sulfate ions with total iron (0.83) (<xref ref-type="table" rid="table2">Table 2</xref>). The Chemical Oxygen Demand (COD) concentrations in the soap discharges are considerably higher than the guide value (500 mg/L), except soap factories Y7, Y10 and P16. The soap factory Y8 has the maximum concentration (51,300 mg/L) which is 103 times the recommended guide value (<xref ref-type="table" rid="table3">Table 3</xref>). For 5-day biochemical oxygen demand (BOD<sub>5</sub>), Y8 (1500 mg/L), Y2 (1700 mg/L) and Y6 (8000 mg/L) effluents have BOD<sub>5</sub> concentrations ranging from 10 to 53 times the limit value of 150 mg/L (<xref ref-type="table" rid="table3">Table 3</xref>). Liquid waste from most soap factories are heavily loaded with oxidable organic and mineral matter. These high COD values derive from the use of organic raw materials (fatty acids, surfactants, glycerin, phenolic compounds, polyalcohols, nitrogenous and phosphorus compounds, colorants, etc.) in the formulation of detergents and cosmetics. Y2, Y6 and Y8 effluents are identified by their high COD concentrations. This fact is worrying and can be explained by the nature of the products manufactured by these industries. Indeed, these soap factories are specialized in the intense production of toilet soaps and cosmetic products (cream, ointment, shampoos, hair products etc.). However, the formulation of these products requires oils and fat products such as surfactants (anionic, cationic, and nonionic), polyalcohols, etc., as basic raw materials. Organic or inorganic synthetic dyes, conservative and antioxidants must be added to the basic components. All these oxidable organic materials contribute to the high COD observed concentrations. The significant correlation of this parameter with sulfate ions (0.70), total iron (0.65) and BOD<sub>5</sub> (0.61) (<xref ref-type="table" rid="table2">Table 2</xref>) justifies this contribution to oxygen demand.</p></sec><sec id="s3_3"><title>3.3. Biodegradability of Industrial Liquid Discharges of Soap Factories (ILDS)</title><p>Analysis of the biodegradability factors (COD/BOD<sub>5</sub>) of the effluents reveals that soap discharges have a COD/BOD<sub>5</sub> ratio ranging between 1.3 and 34 (<xref ref-type="table" rid="table3">Table 3</xref>). Only one soap factory (Y10: COD/BOD<sub>5</sub> = 1.3 &lt; 2) has a biodegradable effluent. Soap factory P16 has an average of biodegradable effluent (COD/BOD<sub>5</sub> = 2.8) between 2 and 3. Soap factories Y10 and P16 certainly have treatment station. Finally, 88.00% of the soap factories show discharges that are difficult to biodegrade with chemical-dominant pollution (COD/BOD<sub>5</sub> &gt; 3), which is characteristic of the chemical industries. The strong correlation of the biodegradability factor with sulfate ions (0.83), total iron (0.81), and orthophosphate ions (0.62) (<xref ref-type="table" rid="table2">Table 2</xref>) corroborates this chemical pollution, leading to the difficult biodegradability of soap effluents. The difficult biodegradability of these discharges is partly related to the specific use of surfactants as the main raw materials in the formulation of detergents and cosmetics. These effluents, which are mainly difficult to biodegrade, damage the environment. In order to propose an appropriate treatment method, it is necessary to group the soap industries studied according to the type of pollution induced by their releases through a multivariate statistical analysis.</p></sec><sec id="s3_4"><title>3.4. Types of Pollution Generated by Industrial Soap Liquid Discharges</title><p>The application of the Principal Components Analysis (PCA) on the whole data allowed to highlight similarities or oppositions between variables, and to locate the most correlated variables between them in order to locate the various pollution generated by the liquid rejections of soap factories in the zone of Abidjan. <xref ref-type="table" rid="table4">Table 4</xref> reveals that the factorial design (F<sub>1</sub> - F<sub>2</sub>) and (F<sub>1</sub> - F<sub>3</sub>) respectively express 56.71% and 55.66% of the original variance of the groups of dots (<xref ref-type="table" rid="table4">Table 4</xref>). These three factors express 78.34% of the explained variance thus releasing the maximum of information on the rejections of soap factories.</p><p>Correlation matrix between physicochemical parameters and the various factors reveals interesting correlations between these factors and some physicochemical parameters. Thus, the main component F<sub>1</sub> defines a strong positive correlation with pH (0.71), E<sub>H</sub> (0.72) and strong negative correlation with EC (−0.72), nutrients <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x26.png" xlink:type="simple"/></inline-formula> (−0.65), <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x27.png" xlink:type="simple"/></inline-formula>(−0.61), <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x28.png" xlink:type="simple"/></inline-formula>(−0.92), sulfates (−0.63), total iron (−0.69) and biodegradability factor BF (−0.69). This principal component characterizes ILDS alcalins, mineral-bearing with a nutritive and chemical pollution. Moreover, the factorial axis F<sub>2</sub> defines a significant correlation with the temperature T (0.66), the chemical oxygen demand COD (0.77), the biochemical oxygen demand of BOD<sub>5</sub> (0.81) and the suspended matter SM (0.75). This axis characterizes an organic pole of pollution. Finally the F<sub>3</sub> factor exhibits a fairly degree correlation with the ions ammonium (−0.55). This axis focuses a nutritive pollution caused by ammonium ion. It results from the analysis of the circle of community and the statistical units of factorial design F<sub>1</sub> - F<sub>2</sub> and F<sub>1</sub> - F<sub>3</sub> (<xref ref-type="fig" rid="fig2">Figure 2</xref>(a) and <xref ref-type="fig" rid="fig2">Figure 2</xref>(b)), four classes of effluents are rejected into the lagoon Ebri&#233; and characterizing four groups of soap factories. Then Group 1 concerns ILDS rich in BOD<sub>5</sub> and in SM, such as soap factory Y6; Group</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Eigenvalues and percentages of the variances expressed by the factors</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Factors</th><th align="center" valign="middle" >Own values</th><th align="center" valign="middle" >% Total variance</th><th align="center" valign="middle" >Accumulation %</th></tr></thead><tr><td align="center" valign="middle" >F<sub>1</sub></td><td align="center" valign="middle" >4.76</td><td align="center" valign="middle" >34.03</td><td align="center" valign="middle" >34.03</td></tr><tr><td align="center" valign="middle" >F<sub>2</sub></td><td align="center" valign="middle" >3.17</td><td align="center" valign="middle" >22.68</td><td align="center" valign="middle" >56.71</td></tr><tr><td align="center" valign="middle" >F<sub>3</sub></td><td align="center" valign="middle" >3.03</td><td align="center" valign="middle" >21.63</td><td align="center" valign="middle" >78.34</td></tr></tbody></table></table-wrap><fig-group id="fig2"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> (a) Circle of community of the factorial design (F<sub>1</sub> - F<sub>2</sub>); (b) Statistical units of the factorial design (F<sub>1</sub> - F<sub>2</sub>); (c) Circle of community of the factorial design (F<sub>1</sub> - F<sub>3</sub>); (d) Statistical units of the factorial design (F<sub>1</sub> - F<sub>3</sub>).</title></caption><fig id ="fig2_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/16-2170469x30.png"/></fig><fig id ="fig2_2"><label>(c)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/16-2170469x29.png"/></fig><fig id ="fig2_3"><label> (d)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/16-2170469x32.png"/></fig><fig id ="fig2_4"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/16-2170469x31.png"/></fig></fig-group><p>2 relates to ILDS with high temperature, rich in COD, iron and in<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x33.png" xlink:type="simple"/></inline-formula>, such as soap factory Y8; Group 3 corresponds to the alkaline, mineral-bearing ILDS and rich in<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x33.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x34.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x33.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x34.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/16-2170469x35.png" xlink:type="simple"/></inline-formula>, and NO<sub>3</sub> (soap factories Y4 and Y9); Group 4 concerns ILDS with low pollutants mentioned above, i.e. soap factories Y1, Y2, Y3, Y5, Y7, Y10, K11, K12, K13, P14, P15, P16 and A17.</p><p>Application of Ascending Hierarchical Classification (AHC) to the result of the PCA permits to specify clearly the above Groups. Thus three (03) groups were distinguished in the following way (<xref ref-type="fig" rid="fig3">Figure 3</xref>). Y2 and group 2 gather and form the main group II. Group 3 and Group 4 gathered to give only one main group, i.e. group III. Finally, three main Groups can be define as following: main Group I corresponds Y6 soap factory; main Group II includes soap factories Y8, Y2 and main Group III is made up from soap factories: Y1, Y3, Y4, Y5, Y7, Y9, Y10, K11, K12, K13, P14, P15, P16 and A17. This result is not enough different from those retrieved from PCA, which revealed four types of pollution generated by the liquid discharges of soap factories. Thus, the seventeen soap mills studied are grouped into three main groups according to the similar physicochemical quality of their releases.</p></sec></sec><sec id="s4"><title>4. Conclusion</title><p>The results of this work show the need to evaluate the level of pollution due to industrial rejection in Abidjan area. These results point out an alarming situation. Except the temperature, most of the other parameters of rejection have concentration which is beyond the national required level. Thus, fifteen (15) out of seventeen (17) selected soap and cosmetic industries (88.00%) discharge their effluents into the Ebri&#233; lagoon without prior treatment. Those effluents are difficultly biodegradable. These soap industries do not have treatment stations or use powerless treatment processes. Moreover, they have very heterogeneous effluents due to both the specific raw materials used for the formulation and above all the non-respect of the laws that regulate their corporation. Moreover, these soap factories are classified into three groups according to the physicochemical quality of their releases: Group I (Y6), Group II (Y8, Y2) and Group III (Y1, Y3, Y5, Y7, Y9, Y10, K11, K12, K13, P14, P15, P16 and A17). Overall, the releases are sources of nutritive, organic and chemical pollution. Also, these discharges exhibit very high and non-biodegradable organic charges which are certainly linked to the use of surfactants that are difficult to biodegrade in the formulation of</p><p>GIII</p><p>GI</p><p>GII</p><p><xref ref-type="fig" rid="fig3">Figure 3</xref>. Ascending hierarchical classification of the studied soap factories.</p><p>detergents and cosmetics. The rejection of these micro pollutants without prior treatment affects the receiving environment. The ILDS, thus, highly contribute to the pollution of the Ebri&#233; lagoon. In response to this sad remark induced by industrial soap liquid discharges, appropriate solutions must be found in terms of protection of the Ebri&#233; lagoon and treatment process of these ILDS before the rejection of their waste. Republic of C&#244;te d’Ivoire must make sure that industrial soap liquid waste is effectively well managed by soap factories. For us, a characterization of the anionic surfactants in ILDS is envisaged because of its wide use as an active ingredient in the formulation of any detergency product and cosmetics. A process for treating these anionic surfactants is envisaged in order to propose it to the soap industries who’s ILDS are rich in these micro pollutants.</p></sec><sec id="s5"><title>Acknowledgements</title><p>The authors thank the state institutions in charge of environment and drainage (ANDE, CIAPOL, and ONAD). They would like to express their sincere thanks to CIAPOL, through the Division of Inspection Services for Classified Installations (D/CIIS) and the Central Environmental Laboratory of the Ivorian Anti-Pollu- tion Center (CEL-CIAPOL) for their contribution to the success of this work.</p></sec><sec id="s6"><title>Cite this paper</title><p>Ehouman, J.M., Yapo, B.O., Eudes Y. Gnagne, A.E.J. and Ziao, N. (2017) Physico-Chemical Charac- terization of Industrial Liquid Discharges of Soap Factories in Abidjan, C&#244;te D’Ivoire. Journal of Geoscience and Environment Protection, 5, 198-210. https://doi.org/10.4236/gep.2017.58016</p></sec></body><back><ref-list><title>References</title><ref id="scirp.78204-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Ahoure Alban, A.E. and Paulin, T.A. (2009) Bilan diagnostic de l’industrie ivoirienne. CAPEEC-CIRES, 37.</mixed-citation></ref><ref id="scirp.78204-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Yoda, N. (2007) Politique de gestion des déchets industriels dans les entreprises du secteur privé à Abidjan. Thèse de Doctorat en Médecine, Université de Cocody, Abidjan, 107.</mixed-citation></ref><ref id="scirp.78204-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Kablan N’guessan Hassy Joseph and Kouakou N’Goran Norbert (2013) Impact environnemental de la zone industrialo-portuaire (ZIP) d’Abidjan. European Scientific Journal, 9, 206-221.</mixed-citation></ref><ref id="scirp.78204-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Adingra, A. (2011) Pollution en lagune Ebrié et ses impacts sur l’environnement et les populations riveraines. F. Tech. &amp; Doc. Vulg, 48-53.</mixed-citation></ref><ref id="scirp.78204-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">United Nations (2006) World Urbanization Prospects: The 2005 Revision. United Nations, New York, 210.</mixed-citation></ref><ref id="scirp.78204-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Institut National de la Statistique (2015) Estimation à partir du RGPH 1998 de la répartition de la population des communes d’Abidjan selon le sexe. 2.</mixed-citation></ref><ref id="scirp.78204-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Afnor (2001) Qualité de l’eau, Eléments majeurs-autres éléments et composés minéraux. Aubenas Ardèche, 6e Edition, 635.</mixed-citation></ref><ref id="scirp.78204-ref8"><label>8</label><mixed-citation publication-type="book" xlink:type="simple">Wolff, M. (2003) Apports de l’analyse géométrique des données pour la modélisation de l’activité. In: Sperandio, J.C. and Wolff, M., Eds., Formalismes de modélisation pour l’analyse du travail et l’ergonomie, Presses Universitaires de France, Paris, 195-227. https://doi.org/10.3917/puf.boppe.2003.01.0195</mixed-citation></ref><ref id="scirp.78204-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Anonyme (2008) Arrêté n° 2008-1164 du 04 novembre 2008, portant sur la réglementation des rejets et émissions des installations classées pour la protection de l’Environnement.</mixed-citation></ref><ref id="scirp.78204-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Rodier, J. (2009) L’Analyse de l’Eau: Eaux Naturelles, Eaux Résiduaires et Eaux de Mer. 9th Edition, DUNOD, Paris, 1384.</mixed-citation></ref><ref id="scirp.78204-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Claude, S. (2001) Oléagineux, Corps Gras, Lipides. Oilseeds and Fats, Crops and Lipids, 8, 134-135. https://doi.org/10.1051/ocl.2001.0134</mixed-citation></ref><ref id="scirp.78204-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Dongo, K.R., Niamke, B.F., Adje, A.F., Britton, B.G.H., Nama,L.A., Anoh, K.P., Adima, A.A. and Atta, K. (2013). Impacts des effluents liquides industriels sur l’environnement urbain d’Abidjan-C&amp;#244te D’Ivoire. The International Journal of Biological and Chemical Sciences, 7, 404-420. https://doi.org/10.4314/ijbcs.v7i1.36</mixed-citation></ref><ref id="scirp.78204-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Affian, K., et al. (2008) Flux de la matière en suspension du fleuve Comoé de la zone littorale ivoirienne. Revue du CAMES, 6, 88-93.</mixed-citation></ref><ref id="scirp.78204-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Zayani, et al. (2002) Etude de la cinétique de dégradation photocatalytique du colorant commercial azo&amp;#239que (Jaune Cibacron FN-2R). Proceedings of International Symposium on Environmental Pollution Control and Waste Management, Tunis, 838-845.</mixed-citation></ref><ref id="scirp.78204-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Moctezumaa (2007) Photocatalytic Degradation of Methyl Parathion: Reaction Pathways and Intermediate Reaction Products. Journal of Photochemistry and Photobiology A: Chemistry, 186, 71-84.</mixed-citation></ref><ref id="scirp.78204-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Bostrom, B. (1984) Potentiel Mobility of Phosphorus in Different Types of Lake Sediment. Internationale Revue der Gesamten Hydrobiologie, 69, 457-474. https://doi.org/10.1002/iroh.19840690402</mixed-citation></ref><ref id="scirp.78204-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Anonyme (2007) Décret N° 2007-491 du 29 mars 2007, interdisant la commercialisation et l’utilisation des phosphates dans les détergents textiles domestiques en Suisse.</mixed-citation></ref><ref id="scirp.78204-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">INERIS (2012) Fiche de données toxicologiques et environnementales des substances chimiques. 110.</mixed-citation></ref><ref id="scirp.78204-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Chambers, P., et al. (2001) Nutrients and Their Impact on the Canadian Environment. Environ. Canada, 241.</mixed-citation></ref><ref id="scirp.78204-ref20"><label>20</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Li</surname><given-names> et al. </given-names></name>,<etal>et al</etal>. (<year>2000</year>)<article-title>Assessment of the Pollutant Elimination Efficiency by Gas Chromatography/Mass Spectrometry, Liquid Chromatography-Mass Spectrometry and Tandem Mass Spectrometry Comparison of Conventional and Membrane-Assisted Biological Wastewater Processes</article-title><source> Journal of Chromatography A</source><volume> 889</volume>,<fpage> 155</fpage>-<lpage>176</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref></ref-list></back></article>