<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">EPE</journal-id><journal-title-group><journal-title>Energy and Power Engineering</journal-title></journal-title-group><issn pub-type="epub">1949-243X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/epe.2017.94B073</article-id><article-id pub-id-type="publisher-id">EPE-75335</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  A Method of Auxiliary Planning for Intelligent Substation Access System Based on Security Region
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Gao</surname><given-names>Yi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Songtao</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Chao</surname><given-names>Qin</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yuan</surname><given-names>Zeng</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yang</surname><given-names>Yang</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yingying</surname><given-names>Liu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Shengwei</surname><given-names>Li</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin, China</addr-line></aff><aff id="aff1"><addr-line>State Grid Tianjin Power Economics &amp;amp; Technology Research Institute, Tianjin, China</addr-line></aff><pub-date pub-type="epub"><day>06</day><month>04</month><year>2017</year></pub-date><volume>09</volume><issue>04</issue><fpage>675</fpage><lpage>682</lpage><history><date date-type="received"><day>March</day>	<month>10,</month>	<year>2017</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>March</month>	<year>30,</year>	</date><date date-type="accepted"><day>April</day>	<month>6,</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   
   This paper presents an auxiliary planning method for intelligent substation access system based on security region. Firstly, the method of resolving the static voltage security region is proposed. Secondly, the method of constructing the optimal index of substation accession is given, which is used to describe the priority of the node into the substation. Finally, a complete set of intelligent substation access system auxiliary planning strategy is given, which takes into account the constraints of the normal operation of the grid on the voltage amplitude. 
  
 
</p></abstract><kwd-group><kwd>Substation</kwd><kwd> the Static Security Region</kwd><kwd> Optimized Index of  Substation Accession</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Intelligent substation as the physical basis of smart grid, will go through the smart grid construction process [<xref ref-type="bibr" rid="scirp.75335-ref1">1</xref>]. With the continuous development of social and economic progress, all walks of life power users of the basic requirements of the power system has been to a more secure, more reliable, more economic change, substation as a particularly important part of the power system, and the most important energy transmission point in the distribution equipment [<xref ref-type="bibr" rid="scirp.75335-ref2">2</xref>]. Whether the substation planning and design is reasonable and whether it can adapt to the violent fluctuation of the load and meet the load development demand in the next few years is extremely important. Therefore, the optimization analysis and evaluation technology of the substation access system is an important content in the power system planning research.</p><p>In paper [<xref ref-type="bibr" rid="scirp.75335-ref3">3</xref>], the safety of the typical access system scheme of the two substations is compared. In paper [<xref ref-type="bibr" rid="scirp.75335-ref4">4</xref>], the main technical scheme of the typical design of 220 kV and 110 kV substations and the technical characteristics of each module are analyzed. In paper [<xref ref-type="bibr" rid="scirp.75335-ref5">5</xref>] According to the principle of minimizing the cost and maximizing the efficiency of the project, and achieving the goal of minimizing the life cycle cost of the project in the whole life, while ensuring the quality of the design, and realizing the maximum economic efficiency and the maximum social benefit of the project construction. At present, at home and abroad in the substation program design method, in addition to the economic comparison phase of the introduction of life cycle cost (Life Cycle Cost, LLC), and not much improvement [<xref ref-type="bibr" rid="scirp.75335-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.75335-ref7">7</xref>].</p><p>In this paper, we use the security region method, which can give the relative position of the current operating point in the domain to characterize the security and stability margin of the whole system [<xref ref-type="bibr" rid="scirp.75335-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.75335-ref9">9</xref>]. By the stability margin information, the weak link of the system is obtained. Based on the boundary coefficient of the security region of the node, the auxiliary decision making scheme for the substation access system is provided.</p></sec><sec id="s2"><title>2. Construction of Static Voltage Security Region</title><p>The mathematical description of the static security region is as follows: For a given network topology, the static security region is a set of all system operating points in the decision space that satisfy the power flow equation <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x2.png" xlink:type="simple"/></inline-formula> and the static security constraint<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x3.png" xlink:type="simple"/></inline-formula>. The mathematical expressions of the static security domain in the decision space:</p><disp-formula id="scirp.75335-formula520"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x4.png"  xlink:type="simple"/></disp-formula><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x5.png" xlink:type="simple"/></inline-formula>denotes the state variable vector of the system, including the voltage phase angle of the generator and the load bus and the voltage amplitude of the load bus, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x6.png" xlink:type="simple"/></inline-formula>denotes the complex power injection vector of the bus, and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x7.png" xlink:type="simple"/></inline-formula> is determined by the system network structure.</p><sec id="s2_1"><title>2.1. Node Power Injection Equation Linearization Processing</title><p>Assuming that the system has n − 1 nodes and nb branches, where node 0 is the equilibrium node, there are g + 1 generator nodes; G is used to denote the set of generator nodes except the equilibrium node; L is the load node A set of all branches.</p><p>According to the node power injection equation:</p><disp-formula id="scirp.75335-formula521"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x8.png"  xlink:type="simple"/></disp-formula><p>Using the method in paper [<xref ref-type="bibr" rid="scirp.75335-ref10">10</xref>] to linearize the node power injection equation. Written in matrix form:</p><disp-formula id="scirp.75335-formula522"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x9.png"  xlink:type="simple"/></disp-formula><p>In the formula, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x10.png" xlink:type="simple"/></inline-formula>is the real part of the admittance matrix, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x11.png" xlink:type="simple"/></inline-formula>is the imaginary part of the admittance matrix, and all are constants.</p></sec><sec id="s2_2"><title>2.2. Static Voltage Security Region</title><p>The decision space of the static voltage safety domain defined in this paper includes the active power injection of the node and the reactive power injection of the load node, and increases the voltage amplitude of the generator node.</p><p>In general, the power system operates in a small neighborhood of the point (V = 1, θ = 0), and the mapping from the V − θ space to the P − Q space is mapped one by one. Therefore, in the V − θ space, the inverse mapping of the Equation (2) exists in a neighborhood of the run point (V = 1, θ = 0).</p><p>Assume that the system has <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x12.png" xlink:type="simple"/></inline-formula> node, where node 0 is a balanced node and has <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x13.png" xlink:type="simple"/></inline-formula> PQ nodes. The set of PV nodes is denoted by G, and L is the set of PQ nodes. The Equation (3) can be written as:</p><disp-formula id="scirp.75335-formula523"><label>(4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x14.png"  xlink:type="simple"/></disp-formula><p>In the formula, Where the PV node and the PQ node are separated. A, B, C, D, E, F, G, H and I are the block matrix, the order is<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x15.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x16.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x17.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x18.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x19.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x20.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x21.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x22.png" xlink:type="simple"/></inline-formula>,<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x22.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x23.png" xlink:type="simple"/></inline-formula>.</p><p>According to the Equation (4):</p><disp-formula id="scirp.75335-formula524"><label>(5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x24.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.75335-formula525"><label>(6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x25.png"  xlink:type="simple"/></disp-formula><p>From the Equation (5), Equation (6) can be obtained:</p><disp-formula id="scirp.75335-formula526"><label>(7)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x26.png"  xlink:type="simple"/></disp-formula><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula>is the upper limit of the voltage amplitude of the load node. <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula>is the current voltage of the load node.<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x29.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x30.png" xlink:type="simple"/></inline-formula>and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x31.png" xlink:type="simple"/></inline-formula> denote the corresponding value in the current operating condition. The row vector <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x31.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x32.png" xlink:type="simple"/></inline-formula> consists of the matrix <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x31.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x32.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x33.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x28.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x31.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x32.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x33.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x34.png" xlink:type="simple"/></inline-formula> in Equation (7).</p><disp-formula id="scirp.75335-formula527"><label>(8)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x35.png"  xlink:type="simple"/></disp-formula><p>The above equation can be organized as:</p><disp-formula id="scirp.75335-formula528"><label>(9)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x36.png"  xlink:type="simple"/></disp-formula><p>Thus, the static security region of the upper limit of the load node voltage can be defined as:</p><disp-formula id="scirp.75335-formula529"><label>(10)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x37.png"  xlink:type="simple"/></disp-formula><p>Similarly, the static safety region of the lower limit of the load node voltage can be defined as:</p><disp-formula id="scirp.75335-formula530"><label>(11)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x38.png"  xlink:type="simple"/></disp-formula><p>The static voltage safety region of the whole system is the intersection of the static voltage safety region where the upper and lower limits of the voltage of all nodes are satisfied.</p><disp-formula id="scirp.75335-formula531"><label>(12)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x39.png"  xlink:type="simple"/></disp-formula></sec></sec><sec id="s3"><title>3. Strategy of Auxiliary Planning for Intelligent Substation Access</title><p>This paper uses the stability margin of the security region to quantify the system security level, to find the node that is closest to the security region boundary under the current operating conditions. This paper presents the optimized index of substation access (OISA), and describes the auxiliary planning strategy of substation access system in detail.</p><sec id="s3_1"><title>3.1. Stability Margin and Safety</title><p>The calculation equation for the stability margin of the load node j is as follows:</p><disp-formula id="scirp.75335-formula532"><label>(13)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x40.png"  xlink:type="simple"/></disp-formula><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x41.png" xlink:type="simple"/></inline-formula>value is positive that the system is safe, the greater the value that the distance from the node’s security region boundary farther, the greater the stability margin.</p><p>The equation of the stability margin of the system (SRM):</p><disp-formula id="scirp.75335-formula533"><label>(14)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x42.png"  xlink:type="simple"/></disp-formula></sec><sec id="s3_2"><title>3.2. Auxiliary Planning Strategy of Substation Access</title><p>According to the optimized index of substation access (OISA), forming appropriate planning.</p><disp-formula id="scirp.75335-formula534"><label>(15)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/75335x43.png"  xlink:type="simple"/></disp-formula><p>The specific method is as follows:</p><p>1) The stability margin analysis of the system is carried out to find the node with the smallest stability margin, meanwhile, obtaining the corresponding domain boundary coefficient information of the node;</p><p>2) Sorting the optimized index of substation access(OISA), the larger the index value of the node, give priority to the node into the substation;</p><p>3) Replace the PQ node with the PV node in the position obtained in step 2);</p><p>4) Recalculate the security region of different schemes and the corresponding system stability margin. By comparison, the optimal access scheme is obtained.</p><p>Auxiliary planning strategy of substation access’s flow chart, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p></sec></sec><sec id="s4"><title>4. Template</title><p>The following is an example of the IEEE 118 node system. The system has a total</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Auxiliary planning strategy of substation access’s flow chart</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/75335x44.png"/></fig><p>of 55 PV nodes, 63 PQ nodes, and node 69 is the balance node. The voltage constraint is<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/75335x45.png" xlink:type="simple"/></inline-formula>. IEEE 118 node system, as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p><p>According to the current power system network topology data, and the corresponding constraints, in the decision space of the system, obtain the corresponding static voltage security region in the current situation. Select the two- dimensional cross-section of the security region boundary corresponding to load node 9 on P11 and Q11.As shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><p>In this paper, different load levels were selected for stability margin analysis. The results are shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><p>From the analysis of Table, the system load increases, the system's stability margin decreases. As the installed capacity of the system is sufficient, the increase of load has little effect on the system stability margin. The current operating point is closest to the security region boundary of BUS 9.</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> IEEE 118 node system</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/75335x46.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Security region boundary corresponding to load node 9 on P11 and Q11</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/75335x47.png"/></fig><p>According to the information on the security region boundary of BUS 9, Sorting the optimized index of substation access (OISA). Part of the data shown in <xref ref-type="table" rid="table2">Table 2</xref>.</p><p>For analysis of OISA, in the <xref ref-type="table" rid="table2">Table 2</xref>, it is advisable to put substations at node 11 and node 13. Option 1: Substation is installed at load node 11; Option 2: Substation is installed at load node 13.</p><p>In the case of input substation parameters consistent, the stability margin analysis for Option 1and Option 2 is shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>From the table can conclude that, access substation in the BUS 11 and BUS 13 can improve system stability margin. However, BUS 11 access substation’s effect of Stability margin improvement is more obvious.</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> The margin information of different access scheme</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/75335x48.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> System stability analysis with different load levels</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Total system load (MW)</th><th align="center" valign="middle" >Stable margin value</th><th align="center" valign="middle" >The margin value corresponds to the load node number</th></tr></thead><tr><td align="center" valign="middle" >4242.0</td><td align="center" valign="middle" >0.047</td><td align="center" valign="middle" >BUS 9</td></tr><tr><td align="center" valign="middle" >4666.2</td><td align="center" valign="middle" >0.0466</td><td align="center" valign="middle" >BUS 9</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> The coefficient of Node 9 security region boundary t, and OISA sorting information</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >variable</th><th align="center" valign="middle" >Boundary coefficient</th><th align="center" valign="middle" >Variable value (Pu)</th><th align="center" valign="middle" >variable</th><th align="center" valign="middle" >Boundary coefficient</th><th align="center" valign="middle" >Variable value (Pu)</th><th align="center" valign="middle" >OISA value</th></tr></thead><tr><td align="center" valign="middle" >Q11</td><td align="center" valign="middle" >0.05017</td><td align="center" valign="middle" >−0.253</td><td align="center" valign="middle" >P11</td><td align="center" valign="middle" >−0.0147</td><td align="center" valign="middle" >−0.77</td><td align="center" valign="middle" >0.023990201</td></tr><tr><td align="center" valign="middle" >Q13</td><td align="center" valign="middle" >0.04302</td><td align="center" valign="middle" >−0.176</td><td align="center" valign="middle" >P13</td><td align="center" valign="middle" >−0.0141</td><td align="center" valign="middle" >−0.374</td><td align="center" valign="middle" >0.01284962</td></tr><tr><td align="center" valign="middle" >Q16</td><td align="center" valign="middle" >0.04106</td><td align="center" valign="middle" >−0.11</td><td align="center" valign="middle" >P16</td><td align="center" valign="middle" >−0.0163</td><td align="center" valign="middle" >−0.275</td><td align="center" valign="middle" >0.009007075</td></tr><tr><td align="center" valign="middle" >Q7</td><td align="center" valign="middle" >0.04241</td><td align="center" valign="middle" >−0.022</td><td align="center" valign="middle" >P7</td><td align="center" valign="middle" >−0.016</td><td align="center" valign="middle" >−0.209</td><td align="center" valign="middle" >0.004270041</td></tr><tr><td align="center" valign="middle" >Q20</td><td align="center" valign="middle" >0.04425</td><td align="center" valign="middle" >−0.033</td><td align="center" valign="middle" >P20</td><td align="center" valign="middle" >−0.014</td><td align="center" valign="middle" >−0.198</td><td align="center" valign="middle" >0.004230664</td></tr><tr><td align="center" valign="middle" >Q17</td><td align="center" valign="middle" >0.0434</td><td align="center" valign="middle" >−0.033</td><td align="center" valign="middle" >P17</td><td align="center" valign="middle" >−0.0167</td><td align="center" valign="middle" >−0.121</td><td align="center" valign="middle" >0.003456626</td></tr><tr><td align="center" valign="middle" >Q2</td><td align="center" valign="middle" >−0.0009</td><td align="center" valign="middle" >−0.099</td><td align="center" valign="middle" >P2</td><td align="center" valign="middle" >−0.0145</td><td align="center" valign="middle" >−0.22</td><td align="center" valign="middle" >0.003085325</td></tr><tr><td align="center" valign="middle" >Q14</td><td align="center" valign="middle" >0.04026</td><td align="center" valign="middle" >−0.011</td><td align="center" valign="middle" >P14</td><td align="center" valign="middle" >−0.0152</td><td align="center" valign="middle" >−0.154</td><td align="center" valign="middle" >0.002787811</td></tr></tbody></table></table-wrap></sec><sec id="s5"><title>5. Conclusion</title><p>In this paper, the direct construction method of static voltage safety domain is proposed. For the first time, the idea of “domain” is applied to the auxiliary planning of intelligent substation. This paper presents a set of complete intelligent substation access system program auxiliary planning method.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This work is supported by the National Science Foundation of China (No.51507108) and the project of State Grid Tianjin Electric Power Company (KJ15-1-08).</p></sec><sec id="s7"><title>Cite this paper</title><p>Yi, G., Zhang, S.T., Qin, C., Zeng, Y., Yang, Y., Liu, Y.Y. and Li, S.W. (2017) A Method of Auxiliary Planning for Intelligent Substation Access System Based on Security Region. Energy and Power Engineering, 9, 675-682. https://doi.org/10.4236/epe.2017.94B073</p></sec></body><back><ref-list><title>References</title><ref id="scirp.75335-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Song, X.K., Han, L. and Huang, J. (2016) Research on the Development of Smart Grid Technology in China. Electric Power Con-struction, 3, 1-11. 
https://doi.org/10.1109/TPEL.2016.2636882</mixed-citation></ref><ref id="scirp.75335-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Song, X.K., Li, J.R., Xiao, Z.H., Lin, H.Y., Li, Z.Y., Zou, G.H., Bao, Y. and Huang, Y.L.(2012) A New Generation of Intelligent Substation overall Design. Power Construction, 11, 1-6.</mixed-citation></ref><ref id="scirp.75335-ref3"><label>3</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Pan</surname><given-names> H.B. </given-names></name>,<etal>et al</etal>. (<year>2004</year>)<article-title>Comparison of Security of Two Kinds of Access System Schemes for Terminal Substation</article-title><source> Electric Power Safety Technology</source><volume> 8</volume>,<fpage> 20</fpage>-<lpage>22</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.75335-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Guo, C.C., Xu, Z.Z. and Xu, X.J. (2007) Study and Application of Typical Design of 220kV and 110kV Substation. Power System Technology, 6, 23-30.</mixed-citation></ref><ref id="scirp.75335-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Li, S.H. and Lu, X.M.(2010) Application of Life Cycle Cost Analysis in Digital Substation Planning and Design. Electric Power Construction, 2, 8-9.</mixed-citation></ref><ref id="scirp.75335-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Li, R.S., Li, Y.B. and Zhou, F.Q.(2010)Intelligent Substation Func-tional Architecture and Design Principles. 2010 China Smart Grid Symposium, 24-27.</mixed-citation></ref><ref id="scirp.75335-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Wu, J.K. (1994) Two Problems of Com-puter Mechanics Program System. Proceedings of Finite Element Analysis and CAD, Peking University Press, Beijing, 9-15.</mixed-citation></ref><ref id="scirp.75335-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Li, J., Xue, A.C., Cao Z.B., Bi, T.S. (2011) On Impact of the Different Models of Generation System to Power System Dynamic Security Region. Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific. 
https://doi.org/10.1109/appeec.2011.5748696</mixed-citation></ref><ref id="scirp.75335-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Almeida, F. C. B., Passos Filho, J. A., Pereira, J. L. R., Marcato, A. L. M. and E. J. de Oliveira. Assessment of the Generator Remote Voltage Control through Static Security Regions. Power and Energy Society General Meeting, 24-29, July 2011, 1-7.</mixed-citation></ref><ref id="scirp.75335-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Wu, Y.J. (2014) Application of a Static Approximation Static Security Domain for Power System Based on Hyperplane and Its Solution. Journal of Electrical Engineering, S1, 374-383.</mixed-citation></ref></ref-list></back></article>