<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">EPE</journal-id><journal-title-group><journal-title>Energy and Power Engineering</journal-title></journal-title-group><issn pub-type="epub">1949-243X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/epe.2017.92010</article-id><article-id pub-id-type="publisher-id">EPE-74396</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Contribution to the Modeling of a Solar Adsorption Refrigerator under the Climatic Conditions of Burkina Faso
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Guy</surname><given-names>Christian Tubreoumya</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Alfa</surname><given-names>Oumar Dissa</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Eloi</surname><given-names>Salmwend&amp;eacute; Tiendrebeogo</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xavier</surname><given-names>Chesneau</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Aboubacar</surname><given-names>Compaor&amp;eacute;</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kayaba</surname><given-names>Haro</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Charles</surname><given-names>Didace Konseibo</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Belkacem</surname><given-names>Zeghmati</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jean</surname><given-names>Koulidiati</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff3"><addr-line>LAboratoire de Math&amp;amp;eacute;matiqueset PhySique (LA.M.P.S), Universit&amp;amp;eacute; de Perpignan Via Domitia (UPVD), Perpignan, France</addr-line></aff><aff id="aff1"><addr-line>Laboratoire de Physique et de Chimie de l’Environnement (L.P.C.E), Universit&amp;amp;eacute; Ouaga I, Ouagadougou, Burkina Faso</addr-line></aff><aff id="aff2"><addr-line>Centre Ecologique Albert Schweitzer (CEAS), Ouagadougou, Burkina Faso</addr-line></aff><pub-date pub-type="epub"><day>10</day><month>02</month><year>2017</year></pub-date><volume>09</volume><issue>02</issue><fpage>119</fpage><lpage>135</lpage><history><date date-type="received"><day>January</day>	<month>27,</month>	<year>2017</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>February</month>	<year>24,</year>	</date><date date-type="accepted"><day>February</day>	<month>27,</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  This work concerns a dynamic modeling and a numerical simulation of the operation of an adsorption solar refrigeration system using the zeolite-water couple. For this, a mathematical model representing the evolution of heat and mass transfer at each component of the solar adsorption refrigerator has been developed. We have adopted the Dubinin-Astakhov model for the adsorption kinetics of the zeolite/water pair. This model allows to describe the phenomenon of adsorption and to calculate the rate of adsorbate (water) in the zeolite (adsorbent) as a function of the temperature and the pressure. The equations governing the operation of the solar adsorption refrigerator, deduced from the thermal and mass balances established at the collector adsorber, condenser and evaporator components, were solved by an implicit finite difference scheme and Gauss Seidel’s iterative method. We have validated the model established by applying it to the model of Allouhi 
  <em>et al. </em>2014. We analyzed the influence of the adsorbate/adsorbent couples, the solar flux, the ambient temperature on the adsorption and desorption process. The temperature profiles obtained representing the temperature evolution of the glass, the absorbent plate, the zeolite-water mixture, the condenser, the evaporator, as well as the pressure and the adsorbed mass allowed us to evaluate the performance of the solar adsorption refrigerator. SCOP is higher the higher the solar flux captured by the collector-adsorber.
 
</p></abstract><kwd-group><kwd>Solar Refrigeration</kwd><kwd> Simulation</kwd><kwd> Adsorption</kwd><kwd> Zeolite/Water</kwd><kwd> Burkina Faso</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Cold production is mainly achieved by compression machines whose operation requires the use of refrigerants and excessive consumption of electrical energy. These refrigerants, CFCs (chlorofluorocarbons), HCFCs (hydrochlorofluoro- carbons) and HFCs (hydrofluorocarbons) are harmful to the ozone layer and contribute to an increase in the greenhouse effect. Since the Montreal Protocol in 1987, international agreements have been signed to reduce emissions of these refrigerants [<xref ref-type="bibr" rid="scirp.74396-ref1">1</xref>] . Thus, research efforts focused on the development of refrige- ration technologies, which respond to environmental and energy concerns, have been undertaken. Solar adsorption refrigeration machines have been the subject of numerous studies [<xref ref-type="bibr" rid="scirp.74396-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref4">4</xref>] .</p><p>These machines are an alternative to solve both ecological and energy problems. Indeed, the technology of these machines is simple, maintenance is easy, and the materials used, are recyclable [<xref ref-type="bibr" rid="scirp.74396-ref5">5</xref>] . In addition, these machines use refrigerants such as water [<xref ref-type="bibr" rid="scirp.74396-ref6">6</xref>] , methanol [<xref ref-type="bibr" rid="scirp.74396-ref7">7</xref>] and ammonia [<xref ref-type="bibr" rid="scirp.74396-ref8">8</xref>] , which have no effect on the environment. For countries such as Burkina Faso, with favorable sunshine with an average irradiation between 5.5 kWh・m<sup>−2</sup>・day<sup>−1</sup> and 65 kWh・hm<sup>−2</sup>・day<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.74396-ref9">9</xref>] , solar adsorption refrigeration is a promising solution to meet important needs such as food preservation, pharmaceuticals, air conditioning, etc. and also to reduce electricity consumption.</p><p>However, some disadvantages have become obstacles to the actual application and marketing of these machines such as discontinuous cycle operation [<xref ref-type="bibr" rid="scirp.74396-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref11">11</xref>] , low coefficient of performance, poor heat and mass transfer in the bed Adsorbent [<xref ref-type="bibr" rid="scirp.74396-ref12">12</xref>] , low thermal conductivity of the adsorbent [<xref ref-type="bibr" rid="scirp.74396-ref13">13</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref15">15</xref>] , poor contact between the surface of the adsorber and the adsorbent [<xref ref-type="bibr" rid="scirp.74396-ref16">16</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref17">17</xref>] .</p><p>To improve the performance of solar adsorption refrigeration machines, numerous research axes have been proposed, studied and tested. Thus, several solar collector models have been used by researchers to optimize the solar radiation received through use: vacuum tube collectors [<xref ref-type="bibr" rid="scirp.74396-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref19">19</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref20">20</xref>] of the single-glazed or double-glazed (TIM) flat plate collectors [<xref ref-type="bibr" rid="scirp.74396-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref23">23</xref>] , cylindro-parabolic collectors [<xref ref-type="bibr" rid="scirp.74396-ref24">24</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref25">25</xref>] .</p><p>Other approaches based on the shape of the adsorber have been used to improve the efficiency of solar radiation. Thus, flat, tubular adsorbers, equipped with external or internal fins, have been used in several prototypes of adsorption solar refrigerators. These fins act as thermal bridges between the absorbent plate and the reactive (porous) medium and thus optimize the heat and mass transfer in the adsorbent bed [<xref ref-type="bibr" rid="scirp.74396-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref27">27</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref28">28</xref>] .</p><p>In addition, some researchers have focused on improving the thermal conductivity of adsorbents through the development of composite adsorbent. The technique for preparing the consolidated composite adsorbents consists in adding a material having a higher thermal conductivity to the powder of the conventional solid adsorbent. By this technique, thermal conductivity of the order of 5 to 15 W/m・k can sometimes be reached and a heat exchange coefficient with the metal walls of the adsorber ranging from 200 to 3000 W/m<sup>2</sup>・k [<xref ref-type="bibr" rid="scirp.74396-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref29">29</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref31">31</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref32">32</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref33">33</xref>] .</p><p>In addition, to overcome the intermittent character of the solar adsorption refrigeration cycle, prototype models of machines have been developed. These machines consist of two beds of adsorbents operating so that one adsorbs the refrigerant and the other one desorbs it. Thus, they make it possible to produce cold continuously [<xref ref-type="bibr" rid="scirp.74396-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref34">34</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref35">35</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref36">36</xref>] .</p><p>The efficiency of the operation of the refrigerating machines is also linked to the climatic conditions of the site in which the machine is located. Thus, several experimental studies on prototypes of adsorption solar refrigerators have been proposed and tested, in order to find their actual behavior [<xref ref-type="bibr" rid="scirp.74396-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref37">37</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref38">38</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref39">39</xref>] [<xref ref-type="bibr" rid="scirp.74396-ref40">40</xref>] .</p><p>The main objective of this study is to contribute to the understanding of the solar refrigeration system by adsorption through a dynamic modeling of a solar adsorption refrigerator model operating under the climatic conditions of Bur- kina Faso.</p></sec><sec id="s2"><title>2. Materials and Methods</title><sec id="s2_1"><title>2.1. Description of the Cycle of Operation of the Solar Adsorption Refrigerator</title><p>A solar refrigerating adsorption machine operates in a cycle. It consists in a flat plate collector containing the zeolite/water mixture and plays a role of capturing and releasing the heat. It is connected to a condenser and an evaporator. The principle of operation of these machines is based on the phenomena of adsor- ption-desorption of a gas (water vapor) in a solid (zeolite). This chemical reac- tion is exo or endothermic according to its direction of unwinding. This ideal cycle represents the evolution of the state of the adsorbent/adsorbate mixture contained in the collector-adsorber. Each cycle includes two main stages gover- ning the operation: one stage for heating the zeolite/water mixture and another for cooling the same mixture.</p><sec id="s2_1_1"><title>2.1.1. Heating Phase</title><p>・ Isosteric heating phase (1 → 2)</p><p>At the beginning of the cycle (point 1), the zeolite/water mixture is at its minimum temperature <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x2.png" xlink:type="simple"/></inline-formula> (adsorption temperature) and at the pressure <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x3.png" xlink:type="simple"/></inline-formula> (evaporation pressure); at this time, the collector-adsorber is isolated. Under heating, the pressure and temperature of the mixture increase, while the total mass of adsorbed water remains constant along the transformation (1 → 2) and equal to<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x4.png" xlink:type="simple"/></inline-formula>. This pressurization phase ends as soon as the pressure becomes equal to that prevailing in the condenser <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x5.png" xlink:type="simple"/></inline-formula> (point 2). The temperature reached is called desorption threshold temperature<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x6.png" xlink:type="simple"/></inline-formula>.</p><p>・ Condensation desorption phase (2 → 3)</p><p>This phase begins when the pressure of the mixture in the adsorber reaches the condensation pressure <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x7.png" xlink:type="simple"/></inline-formula> (saturation pressure corresponding to the temperature of the condenser), the adsorber is placed in communication with the condenser and the desorption of the refrigerant begins, which condenses in the condenser thereafter. The adsorber is then in high pressure and follows the isobar imposed by the condenser. While continuing heating, the temperature of the mixture in the adsorber increases to the maximum temperature <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x8.png" xlink:type="simple"/></inline-formula> (regeneration temperature) at point 3, set for the corresponding cycle. This phase is generally called generation because it is that which makes the adsorber conducive to a new phase of refrigeration production.</p></sec><sec id="s2_1_2"><title>2.1.2. Cooling Phase</title><p>・ Isosteric cooling phase (3 → 4)</p><p>In contrast to the first phase, cooling of the zeolite/water mixture begins at point 3, where the temperature and pressure decrease until the pressure becomes equal to that in the evaporator. The temperature reached is referred to as the adsorption threshold temperature <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x9.png" xlink:type="simple"/></inline-formula> (point 4). The total mass of the adsorbed fluid remains constant during this phase and is equal to<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x10.png" xlink:type="simple"/></inline-formula>.</p><p>・ Adsorption-evaporation phase (4 → 1),</p><p>This phase is the motor phase of the cycle during which the cold is produced. At point 4, the evaporation of the refrigerant begins, producing cold in the evaporator. The vapor produced is adsorbed again in the adsorber until the temperature of the zeolite water mixture becomes minimal<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x11.png" xlink:type="simple"/></inline-formula>, set for the corresponding cycle. During the transformation (4 → 1), the system follows the isobara imposed by the evaporator and which corresponds to the saturation pressure of the refrigerant (water) at the evaporation temperature. At this point, the machine is ready for a new cycle.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref> shows the basic thermodynamic route of such a machine in the Clapeyron diagram (LnP; -1/T) (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Theoretical cycle of an adsorption machine</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x12.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Photography of solar adsorption refrigerator</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x13.png"/></fig></sec></sec><sec id="s2_2"><title>2.2. Modelisation</title><p>The mathematical model presented below simulates the real operation of the solar adsorption refrigeration system taking into account the variation in solar radiation and the ambient temperature during the day. Thus, we present the modeling of the transfer of heat and mass in the adsorbent bed, and the balance equations at each compartment of the system (glass, absorbent plate, condenser, and evaporator).</p><sec id="s2_2_1"><title>2.2.1. Assumptions</title><p>The formulation of some assumptions is necessary for an approximate simulation of the system. Thus we assume that:</p><p>・ The porous material (adsorbent) is assimilated to a medium having a temperature T and equivalent thermal conductivity,</p><p>・ Heat transfer is unidirectional,</p><p>・ The convective heat transfer and the pressure losses are neglected in the porous medium,</p><p>・ The pressure remains constant in the condenser and in the evaporator.</p></sec><sec id="s2_2_2"><title>2.2.2. Equations Balances</title><p>The heat transfer equations at each part of the refrigerator can be written as follows:</p><p>The glass</p><disp-formula id="scirp.74396-formula74"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x14.png"  xlink:type="simple"/></disp-formula><p>The absorbent plat</p><disp-formula id="scirp.74396-formula75"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x15.png"  xlink:type="simple"/></disp-formula><p>The adsorbent bed</p><p>During the isosteric heating and desorption phase</p><disp-formula id="scirp.74396-formula76"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x16.png"  xlink:type="simple"/></disp-formula><p>During the isosteric cooling phase and adsorption</p><disp-formula id="scirp.74396-formula77"><label>(4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x17.png"  xlink:type="simple"/></disp-formula><p>With:</p><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x18.png" xlink:type="simple"/></inline-formula>: During isosteric heating and cooling;</p><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x19.png" xlink:type="simple"/></inline-formula>: During desorption and adsorption;</p><p>The condenser</p><disp-formula id="scirp.74396-formula78"><label>(5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x20.png"  xlink:type="simple"/></disp-formula><p>The evaporator</p><disp-formula id="scirp.74396-formula79"><label>(6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x21.png"  xlink:type="simple"/></disp-formula></sec><sec id="s2_2_3"><title>2.2.3. Model of Adsorption Kinetics</title><p>Several theories of adsorption have been proposed in the literature to describe the process of the adsorption and desorption phenomenon. The Dubinin-As- takhov equation is used successfully to describe the adsorption of gas vapor on the adsorbent. Thus, this equation is used to calculate the rate of adsorbate (water) in the zeolite (adsorbent) as a function of temperature and pressure.</p><disp-formula id="scirp.74396-formula80"><label>(7)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x22.png"  xlink:type="simple"/></disp-formula><p>where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x23.png" xlink:type="simple"/></inline-formula> is the density of the adsorbate (water) and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x23.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x24.png" xlink:type="simple"/></inline-formula> is the saturation pressure. <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x23.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x24.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x25.png" xlink:type="simple"/></inline-formula>is the maximum adsorption capacity; D and n are constants pedending on the adsorbent/adsorbate couple used.</p></sec><sec id="s2_2_4"><title>2.2.4. System Performance</title><p>The solar performance coefficient (SCOP) of a solar refrigerating machine is defined as the ratio between the amount of cold produced at the evaporator and the total solar energy incident for a full day.</p><disp-formula id="scirp.74396-formula81"><label>(8)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x26.png"  xlink:type="simple"/></disp-formula><p>where As is the collecting surface and Gn is the solar flux in W/m<sup>2</sup> <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x27.png" xlink:type="simple"/></inline-formula> is the amount of cold produced at the evaporator, given by:</p><disp-formula id="scirp.74396-formula82"><label>(9)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x28.png"  xlink:type="simple"/></disp-formula></sec></sec><sec id="s2_3"><title>2.3. Numerical Methodology</title><sec id="s2_3_1"><title>2.3.1. Initial and Boundary Conditions</title><p>For all<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x29.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/5-6202014x30.png" xlink:type="simple"/></inline-formula>being the instant from which the collector-adsorber is subjected to the solar flux, we have:</p><disp-formula id="scirp.74396-formula83"><label>(10)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x31.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.74396-formula84"><label>(11)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x32.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.74396-formula85"><label>(12)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/5-6202014x33.png"  xlink:type="simple"/></disp-formula></sec><sec id="s2_3_2"><title>2.3.2. Method of Resolution</title><p>The method of solving the system of equations which describes the transient behavior of the model is purely numerical and based on the implicit finite difference method and the Gauss Seidel iterative method. We have developed and written in Fortran a computer program to model and simulate the adsorption- desorption kinetics of the zeolite/water pair and on the other hand the operation of each element of the refrigerator during a day.</p></sec></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Validation of the Model</title><p>In order to validate our numerical code, we applied our code to the solar adsorption refrigerator model presented by A. Allouhi et al. [<xref ref-type="bibr" rid="scirp.74396-ref41">41</xref>] . This model describes a parallelepiped-shaped collector-adsorber refrigerator using the silicagel-water couple. A comparison between the changes in the temperature in the adsorbent bed as a function of its pressure, describing the Clapeyron cycle of the solar adsorption refrigerator, shows good quantitative agreement. Indeed, the maximum deviation observed for the temperatures is of the order of 1.1% and 2.4% for the pressure (<xref ref-type="fig" rid="fig3">Figure 3</xref>).</p></sec><sec id="s3_2"><title>3.2. Climatic Data</title><p>Solar radiation and ambient temperature are parameters that affect the performance of solar refrigeration systems. Thus, using the weather data provided by the General Direction of Meteorology in Burkina Faso (DGM), which include the values of the monthly global radiation densities on a horizontal plane in J/cm<sup>2</sup>, we used the method of Liu and Jordan to transform these data in order to obtain the hourly values of the global radiation on an inclined plane of angle 12.2˚ with respect to the horizontal. For ambient temperature, we used the data of E. Ou&#233;draogo et al. [<xref ref-type="bibr" rid="scirp.74396-ref42">42</xref>] , who carried out a statistical study to develop an hourly weather file for the city of Ouagadougou. Thus, <xref ref-type="fig" rid="fig4">Figure 4</xref>(a) and <xref ref-type="fig" rid="fig4">Figure 4</xref>(b)</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Comparison of the Clapeyron cycle given by A. Allouhi and our calculation code</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x34.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Main parameters used in the simulation</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Symbols</th><th align="center" valign="middle" >Paramters</th><th align="center" valign="middle" >Values</th><th align="center" valign="middle" >Units</th></tr></thead><tr><td align="center" valign="middle"  colspan="4"  >Properties of the adsorbent/adsorbate (zeolite/water)</td></tr><tr><td align="center" valign="middle" >Cp<sub>ads </sub></td><td align="center" valign="middle" >Chaleur sp&#233;cifique</td><td align="center" valign="middle" >0.836</td><td align="center" valign="middle" >[kJ・kg<sup>−1</sup>・K<sup>−1</sup>]</td></tr><tr><td align="center" valign="middle" >m<sub>ads </sub></td><td align="center" valign="middle" >Masse</td><td align="center" valign="middle" >32</td><td align="center" valign="middle" >[kg]</td></tr><tr><td align="center" valign="middle" >r<sub>ads </sub></td><td align="center" valign="middle" >Densit&#233;</td><td align="center" valign="middle" >620</td><td align="center" valign="middle" >[kg・m<sup>−2</sup>]</td></tr><tr><td align="center" valign="middle" >Cp<sub>l </sub></td><td align="center" valign="middle" >Chaleur sp&#233;cifique</td><td align="center" valign="middle" >4.18</td><td align="center" valign="middle" >[kJ・kg<sup>−1</sup>・K<sup>−1</sup>]</td></tr><tr><td align="center" valign="middle"  colspan="4"  >Collector-adsorber</td></tr><tr><td align="center" valign="middle" >ε<sub>v </sub></td><td align="center" valign="middle" >Emissivity of the glass</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle" >τ<sub>v </sub></td><td align="center" valign="middle" >Transmitivity of the glass</td><td align="center" valign="middle" >0.95</td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle" >α<sub>v </sub></td><td align="center" valign="middle" >Absorptivity of the glass</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle" >e<sub>v </sub></td><td align="center" valign="middle" >Thickness of the glass</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >[m]</td></tr><tr><td align="center" valign="middle" >S</td><td align="center" valign="middle" >Area</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >[m<sup>2</sup>]</td></tr><tr><td align="center" valign="middle" >Cp<sub>v </sub></td><td align="center" valign="middle" >Specific heat of the glass</td><td align="center" valign="middle" >0.75</td><td align="center" valign="middle" >[kJ・kg<sup>−1</sup>・K<sup>−1</sup>]</td></tr><tr><td align="center" valign="middle" >Cp<sub>p </sub></td><td align="center" valign="middle" >Specific heat of the absorbent plate</td><td align="center" valign="middle" >0.896</td><td align="center" valign="middle" >[kJ・kg<sup>−1</sup>・K<sup>−1</sup>]</td></tr><tr><td align="center" valign="middle" >e<sub>p </sub></td><td align="center" valign="middle" >Thickness of absorbent plate</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >[m]</td></tr><tr><td align="center" valign="middle" >α<sub>p </sub></td><td align="center" valign="middle" >Absorptivity of absorbent plate</td><td align="center" valign="middle" >0.95</td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle" >ε<sub>p </sub></td><td align="center" valign="middle" >Emissivity of the absorbent plate</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle"  colspan="4"  >Parameters of Dubinin-Astakhov</td></tr><tr><td align="center" valign="middle" >D</td><td align="center" valign="middle" >Characteristic parameter of the adsorbent/adsorbate couple</td><td align="center" valign="middle" >4.15 10<sup>−7</sup></td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle" >n</td><td align="center" valign="middle" >Characteristic parameter of the adsorbent/adsorbate couple</td><td align="center" valign="middle" >2</td><td align="center" valign="middle" >[-]</td></tr><tr><td align="center" valign="middle" >W<sub>o </sub></td><td align="center" valign="middle" >Maximum adsorption capacity</td><td align="center" valign="middle" >0.269 10<sup>−3 </sup></td><td align="center" valign="middle" >[m<sup>3</sup>・kg<sup>−1</sup>]<sub> </sub></td></tr></tbody></table></table-wrap><fig-group id="fig4"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Hourly evolution of solar radiation and ambient temperature.</title></caption><fig id ="fig4_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x35.png"/></fig><fig id ="fig4_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x36.png"/></fig></fig-group><p>shows the hourly evolution of global solar radiation and the ambient temperature for December, August, October and March. It can be seen that the radiation is maximum in March and minimal in August, this can be explained by the clear sky in March and by a sky low in October and December. In August, this is due to the presence of dust and clouds. These values thus obtained and the values in <xref ref-type="table" rid="table1">Table 1</xref> were used for the simulation of our model.</p></sec><sec id="s3_3"><title>3.3. Dynamic Behavior of the Solar Refrigerator</title><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows the evolution of the temperature of the glass, the absorbent plate and the adsorbent bed (zeolithe) as a function of time during the four phases of</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Time evolution of the temperature of the various components of the solar refrigerator for the month of March</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x37.png"/></fig><p>the cycle. At the beginning of the cycle (the initial state), the temperatures are uniform and equal to the adsorption temperature, which in turn equals the ambient temperature at sunrise. When the solar flux increases, the collector-ad- sorber heats up and the temperatures of its various components increase rapidly with time. They each reach a maximum (Tv = 358 K, Tp = 396 K, Tzeo = 395 K) at about 13 o’clock. The maximum temperature of the adsorbent bed is referred to as the regeneration temperature, that is to say the temperature at which there is no heat exchange between the plate and the adsorbent bed. When the solar flux decreases, the collector-adsorber cooling begins. The temperatures of the various compartments decrease until the temperature reaches 300 K. This temperature represents the temperature in which there is no exchange between the glass pane, the plate and the adsorbent bed.</p><p>The evolution of the temperature of the condenser during the cycle is also shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. At the beginning of the cycle, the temperature of the condenser is the same as that of the ambient. This is explained by the fact that the condenser is isolated from the collector-adsorber during this period. When the desorption-condensation phase begins, the self-contained valve opens and the desorbed water vapor flows into the condenser, resulting in an increase in its temperature. At about 14 o’clock, the temperature of the condenser reaches its maximum at Tcd = 320 K, after which it begins to decrease. This increase in condenser temperature is due in large part to the latent heat of condensation of the water. The decrease of the temperature after 14 o’clock is due, on the one hand, to the cessation of the desorption process and, on the other hand, to cooling by means of the convection and the radiation which the condenser exchanges with the ambient medium. The temperature of the condenser begins to follow that of the ambient temperature during the rest of the day.</p><p>The evolution of the temperature of the evaporator is also shown in the same <xref ref-type="fig" rid="fig5">Figure 5</xref>. The temperature of the evaporator decreases from 297 K to 275 K. This cooling of the evaporator is due to the evaporation of the condensate (water) from the evaporator to the adsorbent bed. Thus, the adsorbate withdraws the needed heat for phase change of the refrigerating enclosure where the evaporator is located. This results in cooling.</p><p><xref ref-type="fig" rid="fig6">Figure 6</xref> shows the variation of the pressure within the adsorbent bed as a function of time. During the phases of the operating cycle, the pressure has a logical behavior with the evolution of the temperature. It increases rapidly from the evaporation pressure Pev = 872 Pa (equal to the saturation pressure at the evaporation temperature) up to a maximum value corresponding to the condensation pressure Pcd = 7376 Pa (equal to the saturation pressure at the condensation temperature). During the desorption phase, the pressure remains constant and equal to the condensation pressure until the temperature of the adsorbent bed reaches the maximum regeneration temperature. Then, it begins to decrease to the low initial evaporation pressure.</p><p>The distribution of the quantity of water adsorbed during the four phases of the cycle is also shown in the same figure. During the cycle, the total quantity of water adsorbed in the adsorbent bed decreases during the desorption phase and then increases during adsorption. It remains constant during the isosteric heating and cooling phases.</p></sec><sec id="s3_4"><title>3.4. Comparison of the Results of the 4 Months</title><p>The evolution of the temperature, the pressure and the quantity of water adsorbed in the adsorbent bed are respectively represented in Figures 7-9. It is clear that the climatic data have a great influence on the Performance of the solar refrigerator. Indeed, for the month of March, the values of the temperature,</p><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Evolution of the pressure and the adsorbed mass for the month of March</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x38.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Comparison of the evolution of the adsorbed mass during the 4 months</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x39.png"/></fig><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Comparison of the evolution of the pressure during the 4 months</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x40.png"/></fig><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Comparison of the evolution of the temperature of the zeolite during the 4 months</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/5-6202014x41.png"/></fig><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Coefficient of performance of the solar adsorption refrigerator</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Month</th><th align="center" valign="middle" >August</th><th align="center" valign="middle" >October</th><th align="center" valign="middle" >December</th><th align="center" valign="middle" >March</th></tr></thead><tr><td align="center" valign="middle" >Qf [MJ]</td><td align="center" valign="middle" >2,1098</td><td align="center" valign="middle" >3,0965</td><td align="center" valign="middle" >4,642</td><td align="center" valign="middle" >6,391</td></tr><tr><td align="center" valign="middle" >Gn-moy (W/m<sup>2</sup>)</td><td align="center" valign="middle" >435,597</td><td align="center" valign="middle" >479,980</td><td align="center" valign="middle" >514,916</td><td align="center" valign="middle" >589,636</td></tr><tr><td align="center" valign="middle" >SCOP</td><td align="center" valign="middle" >0,113</td><td align="center" valign="middle" >0,151</td><td align="center" valign="middle" >0,211</td><td align="center" valign="middle" >0,253</td></tr></tbody></table></table-wrap><p>of the quantity of desorbed adsorbate, are higher compared to the other three months. This is due to the fact that the solar flux density is maximum during this month (990 W/m<sup>2</sup>). The performances of the solar adsorption refrigerator for the four months are also shown in the <xref ref-type="table" rid="table2">Table 2</xref>. For the month of March, the SCOP reached is 0.25, while for the other months the SCOP is equal to 0.21 for the month of December, 0.15 for the month of October and 0.11 for the month of August.</p></sec></sec><sec id="s4"><title>4. Conclusions</title><p>This work presents the modeling of a system of solar refrigeration by adsorption which uses the couple zeolite and water. Thus, through a mathematical model, we wrote the equations of balance at each part of the refrigerator and developed a program written in Fortran language in order to simulate the behavior of the refrigerator taking into account the climatic conditions of the city of Ouagadougou. The temperature changes of the glass, the absorbent plate, the conden- ser, the evaporator, the adsorbent bed and its pressure and the adsorbed mass were discussed.</p><p>The key findings are:</p><p>・ For March and December, the average solar flux densities are 590 W/m<sup>2</sup> and 514 W/m<sup>2</sup> respectively. The amount of cold produced during these months is 6.391 MJ for the month of March and 4.642 MJ for the month of December. This gives a SCOP of 0.25 and 0.21 for the months of March and December.</p><p>・ With an average daily solar flux density of 436 W/m<sup>2</sup> and 480 W/m<sup>2</sup> respectively for the months of August and October, the SCOP reached by our solar refrigeration system is 0.11 and 0.15, with a total product amount of 2.12 and 3.1 MJ.</p><p>The dynamic model thus developed allows to predict the real operation of the solar adsorption refrigerator and to evaluate its performance according to the climatic conditions of the city of Ouagadougou (Burkina Faso) for the hottest months and the coldest months of the year. The results obtained are very encouraging to continue to improve the performance of the solar adsorption refrigerator in order to use it in industrial and domestic domains.</p></sec><sec id="s5"><title>Acknowledgements</title><p>The authors are grateful to the University Agency of the Francophonie (AUF) and the French Embassy (SCAC) for financial support which allowed the realization of this work.</p></sec><sec id="s6"><title>Cite this paper</title><p>Tubreoumya, G.C., Dissa, A.O., Tiendrebeogo, E.S., Chesneau, X., Compaor&#233;, A., Haro, K., Konseibo, C.D., Zeghmati, B. and Koulidiati, J. (2017) Contribution to the Modeling of a Solar Adsorp- tion Refrigerator under the Climatic Conditions of Burkina Faso. Energy and Power Engineering, 9, 119-135. https://doi.org/10.4236/epe.2017.92010</p></sec><sec id="s7"><title>Nomenclature</title><p>Cp</p><p>Sp&#233;cific heat (J/kg.K)</p><p>ΔH</p><p>Heat of</p><p>adsorption/desorption (J/kg)</p><p>D</p><p>Constant in the Dubinin-Astakhov Equation</p><p>Subscripts</p><p>Gn</p><p>Solar radiation (W/m<sup>2</sup>)</p><p>a</p><p>adsorption</p><p>m</p><p>mass (kg)</p><p>ads</p><p>adsorbent</p><p>n</p><p>Constant in the Dubinin-Astakhov Equation</p><p>d</p><p>desorption</p><p>P</p><p>Pressure (Pa)</p><p>cd</p><p>condenser</p><p>P<sub>s </sub></p><p>Saturation Pressure (Pa)</p><p>ev</p><p>evaporater</p><p>Q<sub>f </sub></p><p>Cold production (J)</p><p>v</p><p>glass</p><p>q</p><p>Water concentration inside the z&#233;olithe (kg/kg)</p><p>ext</p><p>outside</p><p>S</p><p>Area (m<sup>2</sup>)</p><p>amb</p><p>ambient</p><p>T</p><p>Temp&#233;rature (K)</p><p>zeo</p><p>zeolithe</p><p>t</p><p>Time (s)</p><p>min/max</p><p>minimum</p><p>W<sub>o </sub></p><p>Parameter of Dubinin-Astrakhov Equation (m<sup>3</sup>/kg)</p><p>max</p><p>maximum</p><p>L(T)</p><p>Latent heat of vaporization (J/kg)</p><p>g</p><p>generation</p><p>Greek Letters:</p><p>cv</p><p>convection</p><p>α</p><p>absorptance</p><p>moy</p><p>average</p><p>τ</p><p>Transmitance</p><p>eau</p><p>water</p><p>Δt</p><p>Time step (s)</p><disp-formula id="scirp.74396-formula86"><graphic  xlink:href="http://html.scirp.org/file/5-6202014x42.png"  xlink:type="simple"/></disp-formula><p>Submit or recommend next manuscript to SCIRP and we will provide best service for you:</p><p>Accepting pre-submission inquiries through Email, Facebook, LinkedIn, Twitter, etc.</p><p>A wide selection of journals (inclusive of 9 subjects, more than 200 journals)</p><p>Providing 24-hour high-quality service</p><p>User-friendly online submission system</p><p>Fair and swift peer-review system</p><p>Efficient typesetting and proofreading procedure</p><p>Display of the result of downloads and visits, as well as the number of cited articles</p><p>Maximum dissemination of your research work</p><p>Submit your manuscript at: http://papersubmission.scirp.org/</p><p>Or contact epe@scirp.org</p></sec></body><back><ref-list><title>References</title><ref id="scirp.74396-ref1"><label>1</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Anyanwu</surname><given-names> E. </given-names></name>,<etal>et al</etal>. (<year>2000</year>)<article-title>Environmental Pollution: Restructuring the Refrigeration Industry as a Way out</article-title><source> Environment Protection Engineering</source><volume> 26</volume>,<fpage> 17</fpage>-<lpage>28</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.74396-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Hadj Ammara, M., Benhaoua, B. and Balghouthi, M. (2015) Simulation of Tubular Adsorber for Adsorption Refrigeration System Powered by Solar Energy in Sub-Sahara Region of Algeria. Energy Conversion and Management, 106, 31-40.  
https://doi.org/10.1016/j.enconman.2015.09.013</mixed-citation></ref><ref id="scirp.74396-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Umair, M., Akisawa, A. and Ueda, Y. (2014) Performance Evaluation of a Solar Adsorption Refrigeration System with a Wing Type Compound Parabolic Concentrator. Energies, 7, 1448-1466. https://doi.org/10.3390/en7031448</mixed-citation></ref><ref id="scirp.74396-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Qasem, N. and El-Shaarawi, M. (2013) Improving Ice Productivity and Performance for an Activated Carbon/Methanol Solar Adsorption Ice-Maker. Solar Energy, 98, 523-542. https://doi.org/10.1016/j.solener.2013.10.018</mixed-citation></ref><ref id="scirp.74396-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Chikouche, A. (2012) Using Solar Energy for Refrigeration Purposes in Algeria.</mixed-citation></ref><ref id="scirp.74396-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Uyun, M.A., Miyazaki, T., Ueda, Y. and Akisawa, A. (2010) Performance Analysis of a Double-Effect Adsorption Refrigeration Cycle with a Silica Gel/Water Working Pair. Energies, 3, 1704-1720. https://doi.org/10.3390/en3111704</mixed-citation></ref><ref id="scirp.74396-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Hassan, H., Mohamad, A. and Al-Ansary, H. (2012) Development of a Continuously Operating Solar-Driven Adsorption Cooling System: Thermodynamic Analysis and Parametric Study. Applied Thermal Engineering, 48, 332-341.  
https://doi.org/10.1016/j.applthermaleng.2012.04.040</mixed-citation></ref><ref id="scirp.74396-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Louajari, M., Mimet, A. and Ouammi, A. (2011) Study of the Effect of Finned Tube Adsorber on Theperformance of Solar Driven Adsorption Cooling Machine Using Activated Carbon-Ammonia Pair. Applied Energy, 88, 690-698.  
https://doi.org/10.1016/j.apenergy.2010.08.032</mixed-citation></ref><ref id="scirp.74396-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Ousmane, M., Dianda, B., Kam, S., Konfe, A., Ky, T. and Bathiebo, D. (2015) Experimental Study in Natural Convection. Global Journal of Pure and Applied Sciences, 21, 155-169. https://doi.org/10.4314/gjpas.v21i2.8</mixed-citation></ref><ref id="scirp.74396-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Anyanwu, E. (2003) Review of Solid Adsorption Solar Refrigerator I: An Overview of the Refrigeration Cycle. Energy Conversion and Management, 44, 301-312.  
https://doi.org/10.1016/S0196-8904(02)00038-9</mixed-citation></ref><ref id="scirp.74396-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Meunier, F. (2001) Adsorptive Cooling: A Clean Technology. Clean Products and Processes, 3, 8-20. https://doi.org/10.1007/s100980000096</mixed-citation></ref><ref id="scirp.74396-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Fadar, A.E. (2015) Thermal Behavior and Performance Assessment of a Solar Adsorption Cooling System with Finned Absorber. Energy, 83, 674-684.  
https://doi.org/10.1016/j.energy.2015.02.074</mixed-citation></ref><ref id="scirp.74396-ref13"><label>13</label><mixed-citation publication-type="book" xlink:type="simple">Critoph, R.E. (1999) Adsorption Refrigerators and Heat Pumps. In: Burchell, T.D., Ed., Carbon Materials for Advanced Technologies, Elsevier, Amsterdam, 303-340.  
https://doi.org/10.1016/B978-008042683-9/50012-1</mixed-citation></ref><ref id="scirp.74396-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Mhimid, A., Jemni, A.A. and Nasrallah, B.S. (1997) Etude th&amp;eacute;orique des transferts couples de chaleur et de masse lors de la d&amp;eacute;sorption du couple Z&amp;eacute;olithe 13X-eau. Revue G&amp;eacute;n&amp;eacute;rale de Thermique, 36, 697-706.  
https://doi.org/10.1016/S0035-3159(97)88434-6</mixed-citation></ref><ref id="scirp.74396-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Jemni, A. and Ben Nasrallah, S. (1995) Study of Two-Dimensional Heat and Mass Transfer during Desorption in a Metal-Hydrogen Reactor. International Journal of Hydrogen Energy, 20, 881-891. https://doi.org/10.1016/0360-3199(94)00115-G</mixed-citation></ref><ref id="scirp.74396-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Critoph, R. and Turner, L. (1995) Heat Transfer in Granular Activated Carbon Beds in the Presence of Adsorbable Gases. International Journal of Heat and Mass Transfer, 38, 1577-1585. https://doi.org/10.1016/0017-9310(94)00276-2</mixed-citation></ref><ref id="scirp.74396-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Almers, A., Azzabakh, A. and Mimet, A. (2006) Optimal Design Study of Cylindrical Finned Reactor for Solar Adsorption Cooling Machine Working with Activated Carbon-Ammonia Pair. Applied Thermal Engineering, 26, 1866-1875.  
https://doi.org/10.1016/j.applthermaleng.2006.01.021</mixed-citation></ref><ref id="scirp.74396-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Chekirou, W., Boukheit, W. and Kerbache, T. (2007) Numerical Modeling of Combined Heat and Mass Transfer in a Tubular Adsorber of a Solid Adsorption Solar Refrigerator. Revue des Energies Renouvelables, 10, 367-379.</mixed-citation></ref><ref id="scirp.74396-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Hassan, H., Mohamad, A. and Bennacer, R. (2011) Simulation of an Adsorption Solar Cooling System. Energy, 36, 530-537.  
https://doi.org/10.1016/j.energy.2010.10.011</mixed-citation></ref><ref id="scirp.74396-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Mohamed, L., Abdelaziz, M. and Ahmed, O. (2011) Study of the Effect of Finned Tube Adsorber on the Performance of Solar Driven Adsorption Cooling Machine Using Activated Carbon-Ammonia Pair. Applied Energy, 88, 690-698.  
https://doi.org/10.1016/j.apenergy.2010.08.032</mixed-citation></ref><ref id="scirp.74396-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Naef, A., Qasem, M. and El-Shaarawi, A. (2013) Improving Ice Productivity and Performance for an Activated Carbon/Methanol Solar Adsorption Ice-Maker. Solar Energy, 98, 523-542. https://doi.org/10.1016/j.solener.2013.10.018</mixed-citation></ref><ref id="scirp.74396-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Li, M., Sun, C., Wang, R. and Cai, W. (2004) Development of No Valve Solar Ice Maker. Applied Thermal Engineering, 24, 865-872.  
https://doi.org/10.1016/j.applthermaleng.2003.10.002</mixed-citation></ref><ref id="scirp.74396-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Leite, A., Grilo, M., Andrade, R., Belo, F. and Meunier, F. (2007) Experimental Thermodynamic Cycles and Performance Analysis of a Solar-Powered Adsorptive Ice Maker in Hot Humid Climate. Energy Renewable, 32, 697-712.  
https://doi.org/10.1016/j.renene.2006.03.002</mixed-citation></ref><ref id="scirp.74396-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Muhammad, U., Atsushi, A. and Yuki, U. (2014) Performance Evaluation of a Solar Adsorption Refrigeration System with a Wing Type Compound Parabolic Concentrator. Energies, 7, 1448-1466. https://doi.org/10.3390/en7031448</mixed-citation></ref><ref id="scirp.74396-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Bakkas, M., Mada, M. and Tahri, M. (2001) Mod&amp;eacute;lisation et Simulation du Transfert de Chaleur et de Masse &amp;agrave; l'Int&amp;eacute;rieur d'un R&amp;eacute;acteur de Charbon Actif R&amp;eacute;agissant avec de l’Ammoniac Coupl&amp;eacute; &amp;agrave; un Caloduc Annulaire &amp;agrave; Eau. Revue des Energies Renouvelables, 19-24.</mixed-citation></ref><ref id="scirp.74396-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Allouhi, A., Kousksou, T., Jamil, A., El Rhafiki, T., Mourad, Y. and Zeraouli, Y. (2015) Optimal Working Pairs for Solar Adsorption Cooling Applications. Energy, 79, 235-247. https://doi.org/10.1016/j.energy.2014.11.010</mixed-citation></ref><ref id="scirp.74396-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Leite, A.D.M. (2000) Performance of a New Solid Adsorption Ice Maker with Solar Energy Regeneration. Energy Conversion and Management, 41, 1625-1647.  
https://doi.org/10.1016/S0196-8904(00)00011-X</mixed-citation></ref><ref id="scirp.74396-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Guilleminot, J.M.F. (1987) Heat and Mass Transfer in a Non Isothermal Fixed Bed Solid Adsorbent Reactor a Uniform Pressure-Non Uniform Temperature. International Journal of Heat and Mass Transfer, 30, 1595-1606.  
https://doi.org/10.1016/0017-9310(87)90304-8</mixed-citation></ref><ref id="scirp.74396-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Mimet, A. (1991) Etude th&amp;eacute;orique et exp&amp;eacute;rimentale d’une machine frigorifique &amp;agrave; adsorption d’ammoniac sur charbon actif. Thèse de Doctorat, FPMs, Mons.</mixed-citation></ref><ref id="scirp.74396-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Iloeje, O., Ndili, A. and Enibe, S. (1995) Computer Simulation of a CaCl2, Solid Adsorption Solar Refrigerator. Energy, 20, 1141-1151.  
https://doi.org/10.1016/0360-5442(95)00050-Q</mixed-citation></ref><ref id="scirp.74396-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Eun, T.-H., et al. (2000) Enhancement of Heat and Mass Transfer in Silica-Expanded Graphite Coposite Blocks for Adsorption Heat Pumps: Part I. Characterisation of the Composite Blocks. International Journal of Refrigeration, 23, 64-73.  
https://doi.org/10.1016/S0140-7007(99)00035-3</mixed-citation></ref><ref id="scirp.74396-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Lemmini, F. and Errougani, A. (2007) Experimentation of a Solar Adsorption Refrigerator in Morocco. Renewable Energy, 32, 2629-2641.  
https://doi.org/10.1016/j.renene.2007.01.004</mixed-citation></ref><ref id="scirp.74396-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Pons, M., Laurent, D. and Meunier, F. (1996) Experimental Temperature Fronts For Adsorptive Heat Pump Applications. Applied Thermal Engineering, 16, 395-404.  
https://doi.org/10.1016/1359-4311(95)00025-9</mixed-citation></ref><ref id="scirp.74396-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Rahman, A., Miyazaki, T., Ueda, Y., Saha, B. and Akisawa, A. (2013) Performance Comparison of Three-Bed Adsorption Cooling System with Optimal Cycle Time Setting. Heat Transfer Engineering, 34, 938-947.  
https://doi.org/10.1080/01457632.2012.753571</mixed-citation></ref><ref id="scirp.74396-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Uyun, A., Akisawa, A., Miyazaki, T., Ueda, Y. and Kashiwagi, T. (2009) Numerical Analysis of an Advanced Three-Bed Mass Recovery Adsorption Refrigeration Cycle. Applied Thermal Engineering, 29, 2876-2884.  
https://doi.org/10.1016/j.applthermaleng.2009.02.008</mixed-citation></ref><ref id="scirp.74396-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Muhammad, U., Atsushi, A. and Yuki, U. (2014) Simulation Study of Continuous Solar Adsorption Refrigeration System Driven by Compound Parabolic Concentrator. Renewable Energy Journal, 7, 1-12.  
https://doi.org/10.2174/1876387101407010001</mixed-citation></ref><ref id="scirp.74396-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Lemmini, F., Buret-Bahraoui, J., Pons, M. and Meunier, F. (1992) Simulation des performances d’un r&amp;eacute;frig&amp;eacute;rateur solaire &amp;agrave; adsorption: 1. Comparaison des performances pour deux types de charbon actif. International Journal of Refrigeration, 15, 159-167. https://doi.org/10.1016/0140-7007(92)90006-G</mixed-citation></ref><ref id="scirp.74396-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Boubakri, A., Guilleminot, J. and Meunier, F. (2000) Adsorptive Solar Powered Ice Maker: Experiments and Model. Solar Energy, 69, 249-263.  
https://doi.org/10.1016/S0038-092X(00)00063-3</mixed-citation></ref><ref id="scirp.74396-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Kreussler, S. and Bolz, D. (2000) Experiments on Solar Adsorption Refrigeration Using Zeolite and Water. Laboratory for Solar Energy, University of Applied Sciences, Lubeck.</mixed-citation></ref><ref id="scirp.74396-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Li, M., Wang, R., Xu, Y., Wu, J. and Dieng, A. (2002) Experimental Study on Dynamic Performance Analysis of a Flat-Plate Solar Solid-Adsorption Refrigeration for Ice Maker. Renewable Energy, 27, 211-221.  
https://doi.org/10.1016/S0960-1481(01)00188-4</mixed-citation></ref><ref id="scirp.74396-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Allouhi, A., Kousksou, T., Jamil, A. and Zeraouli, Y. (2014) Modeling of a Thermal Adsorber Powered by Solar Energy for Refrigeration Applications. Energy, 75, 589-596. https://doi.org/10.1016/j.energy.2014.08.022</mixed-citation></ref><ref id="scirp.74396-ref42"><label>42</label><mixed-citation publication-type="other" xlink:type="simple">Ouedraogo, E., Coulibaly, O. and Ouedraogo, A. (2012) Elaboration d’une ann&amp;eacute;e m&amp;eacute;t&amp;eacute;orologique type de la ville de Ouagadougou pour l’&amp;eacute;tude des performances &amp;eacute;nerg&amp;eacute;tiques des batiments. Revue des Energies Renouvelables, 15, 77-90.</mixed-citation></ref></ref-list></back></article>