<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">MSCE</journal-id><journal-title-group><journal-title>Journal of Materials Science and Chemical Engineering</journal-title></journal-title-group><issn pub-type="epub">2327-6045</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/msce.2017.51013</article-id><article-id pub-id-type="publisher-id">MSCE-73666</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Influence of Deep Cryogenic Treatment (DCT) on Thermo Mechanical Performance of AISI H13 Tool Steel
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Valmik</surname><given-names>Bhawar</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Shreyans</surname><given-names>Khot</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Prakash</surname><given-names>Kattire</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mohan</surname><given-names>Mehta</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Rajkumar</surname><given-names>Singh</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Kalyani Center for Technology and Innovation, Bharat Forge Ltd., Pune, India</addr-line></aff><pub-date pub-type="epub"><day>04</day><month>01</month><year>2017</year></pub-date><volume>05</volume><issue>01</issue><fpage>91</fpage><lpage>101</lpage><history><date date-type="received"><day>December</day>	<month>15,</month>	<year>2016</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>January</month>	<year>13,</year>	</date><date date-type="accepted"><day>January</day>	<month>16,</month>	<year>2017</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   
   Deep cryogenic treatment (DCT) is one of the most recent processes being used to treat tool steels. It is a supplementary treatment where components are treated below subzero temperatures for several cryo-soaking hours. This paper focuses on to study the effect of deep cryogenic treatment on Thermo mechanical properties of AISI H-13 tool steel. Deep cryogenic treatment at 32 hours of cryo-soaking time is applied and thermo mechanical performance of tool steel was analyzed by using pin on disk high temperature wear testing and stress rupture testings. The microstructural evolutions during DCT were evaluated by using scanning electron microscope (SEM). It was observed that microstructural modifications like increase in carbide density, fine and uniform martensitic structure during DCT had significantly improved properties. 
  
 
</p></abstract><kwd-group><kwd>Cryogenic Treatment</kwd><kwd> Wear Resistance</kwd><kwd> Tool Steel</kwd><kwd> H-13 Tool Steel</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>AISI H13 Hot work tool steel is used in making various tools. However in working condition these tools undergo surface failures like wear, deformation, cracks. Although conventional heat treatments are available like hardening and tempering, nitriding but treatments like DCT will further improve performance of tool material. In Deep cryogenic treatment material to be treated is kept at −190˚C for long hours and slowly brought to room temperature followed by tempering. Several treatment time and temperature profiles are available depending on the material and volume to be treated. DCT can be used for wide range of industrial tooling applications, like machining tools (milling, cutting, drilling etc.) and press tools (hot and cold forging dies, extrusion dies, punches, shearing tools etc.) because it enhances tool life which results in cost savings. It is a one-time and permanent treatment where entire mass is treated so that benefits could be realized even after regrinding or re-sharpening of tools unlike in surface treatments. Though DCT has several benefits, it is an additional treatment along with conventional heat treatment and not a replacement of it [<xref ref-type="bibr" rid="scirp.73666-ref1">1</xref>]. It is usually carried out after conventional heat treatment, like hardening and tempering. Several advantages of cryogenic treatment like increase in hardness and tensile strength, increase in wear resistance, more impact toughness, low brittleness, low residual stresses and higher thermal stability, are particularly useful for tool steels to enhance fatigue life [<xref ref-type="bibr" rid="scirp.73666-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref3">3</xref>]. While improvements of 44% - 126% [<xref ref-type="bibr" rid="scirp.73666-ref4">4</xref>] and 301% [<xref ref-type="bibr" rid="scirp.73666-ref5">5</xref>] in tool life were recorded, the reported improvement in wear rate was in the range of 56% - 87% [<xref ref-type="bibr" rid="scirp.73666-ref6">6</xref>] in case of M2 HSS tool steels. Similarly, significant improvements in tool life and wear rate were also reported for M35 HSS tool steels [<xref ref-type="bibr" rid="scirp.73666-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref8">8</xref>]. In the similar lines, published literature on D3 and D6 type tool steel demonstrated 39% - 68% [<xref ref-type="bibr" rid="scirp.73666-ref9">9</xref>] and 52% [<xref ref-type="bibr" rid="scirp.73666-ref10">10</xref>] improvements in wear rate. However, the microstructural mechanisms which are responsible for these improvements are not yet fully understood and needs further investigations [<xref ref-type="bibr" rid="scirp.73666-ref11">11</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref12">12</xref>]. Some of the common mechanisms which are discussed in most of the literatures are complete transformation of retained austenite to martensite, precipitation of tertiary carbides (ETA carbides) and their uniform distribution in martensitic matrix and creation of more denser molecular structure [<xref ref-type="bibr" rid="scirp.73666-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref13">13</xref>].</p><p>Zbigniew Latas et al. [<xref ref-type="bibr" rid="scirp.73666-ref14">14</xref>] did research on cryogenic processing of hot forging tool steels (55NiCrMoV6 and X38CrMoV5-1) and claimed significant increase in the hardness and wear resistance by using DCT as compared to the conventional heat treatment. M. Parez et al. [<xref ref-type="bibr" rid="scirp.73666-ref15">15</xref>] claimed 22% - 24% improvement in fracture toughness of cryogenically treated H-13 tool steel as compared to conventional treatment. Mahdi Koneshlou et al. [<xref ref-type="bibr" rid="scirp.73666-ref13">13</xref>] examined the effect of DCT on AISI H-13 tool steel where they reported improvement in hardness, tensile strength, impact energy and wear resistance. The improvement in these properties was explained by the transformation of retained austenite to martensite, precipitation of very fine carbides and more uniform &amp; smaller martensitic lath microstructure. Adam Cicek et al. [<xref ref-type="bibr" rid="scirp.73666-ref16">16</xref>] compared effect of cryogenic and hardening heat treatment on machinability of h13 tool steel and found reduction in wear rate, surface roughness and cutting forces for cryogenically treated steel.</p><p>Though wide literature is available on DCT stating its advantages in terms of wear resistance and mechanical properties, less emphasis is given on thermo mechanical properties of tool steels. This is the main focus of the presented investigations on the AISI H-13 tool steel.</p></sec><sec id="s2"><title>2. Materials and Experimental Procedure</title><sec id="s2_1"><title>2.1. Experimental</title><p>The commercial grade of AISI H-13 tool steel was selected for the present work. <xref ref-type="table" rid="table1">Table 1</xref> shows chemical composition of this material in annealed condition</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Chemical composition of AISI H-13 tool steel (annealed condition)</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Elements</th><th align="center" valign="middle" >C</th><th align="center" valign="middle" >Mn</th><th align="center" valign="middle" >Si</th><th align="center" valign="middle" >Cr</th><th align="center" valign="middle" >Ni</th><th align="center" valign="middle" >Mo</th><th align="center" valign="middle" >V</th><th align="center" valign="middle" >S</th><th align="center" valign="middle" >P</th><th align="center" valign="middle" >Fe</th></tr></thead><tr><td align="center" valign="middle" >Weight %</td><td align="center" valign="middle" >0.385</td><td align="center" valign="middle" >0.35</td><td align="center" valign="middle" >1.049</td><td align="center" valign="middle" >5.11</td><td align="center" valign="middle" >0.152</td><td align="center" valign="middle" >1.278</td><td align="center" valign="middle" >0.993</td><td align="center" valign="middle" >0.001</td><td align="center" valign="middle" >0.014</td><td align="center" valign="middle" >Remaining</td></tr></tbody></table></table-wrap><p>which was analyzed by vacuum emission spectrometer. Small samples of ap- propriate dimensions required for microstructural, hardness, stress rupture and wear analysis were prepared from this material for planned research. All pre- pared samples were then exposed to regular heat treatment including hardening and tempering. Both of these treatments were carried out in muffle furnace with controlled heating. During hardening samples were held at 1030˚C for 60 minutes for austenitizing followed by quenching in oil stirred bath. After hardening, samples were then tempered at 560˚C for 2 hours followed by air cooling to room temperature. This was the conventional heat treatment cycle used for all specimens under consideration in this study and samples named as harden &amp; tempered (HT) samples.</p><p>Few samples from HT group were then deep cryogenically treated in a com- puter controlled cryo-processor (Sanmer make, −185˚C). The temperature inside the cryo-processor was controlled by supplying calculated gasified liquid nitrogen through solenoid valve. The samples were first cooled down to −185˚C at the rate of 3˚C/min to avoid thermal shock and then soaked for 32 hour as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. After the completion of soaking time, samples were removed from the cryo-processor and stored in insulated thermocol until they attain room temperature. All samples were then processed through soft tempering at 110˚C with 2 hours soaking, followed by air cooling to room temperature.</p></sec><sec id="s2_2"><title>2.2. Characterization</title><p>Microstructural analysis was carried out by using scanning electron microscope (EV018 Carl Zeiss make). The samples were subjected to series of emery paper (1/0, 2/0, 3/0 and 4/0) polishing followed by velvet cloth polishing with intermittent application of fine suspension of diamond paste. Finally samples were cleaned with acetone and etched with 2% nital etchant. The impact toughness of already prepared notched samples (as per ASTM A370 standard) was determined by using Zwick Roell make impact tester. Average impact toughness (J) of three samples for each material condition was taken as measure of impact toughness. Hardness measurement was carried out on Matsuawa with Celmex make micro-hardness tester.</p><p>Samples were polished by using 300 and 400G polish papers before hardness testing. The averages of three measurements were recorded for each material condition.</p><p>Stress rupture tests were conducted with Applied Test System (ATS) model 2410 having three zone furnace controlled by WINCCS software. The specimens used for stress rupture testing were similar to that used for tensile test (ASTM standard E8-91). Test setup and specimen conditions are shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The specimen was placed in the center zone of the furnace to maintain a constant</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Deep cryogenic treatment (DCT) cycle</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x2.png"/></fig><fig-group id="fig2"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> ATS creep testing setup &amp; stress rupture specimen test condition.</title></caption><fig id ="fig2_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x3.png"/></fig><fig id ="fig2_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x4.png"/></fig></fig-group><p>temperature along the gauge length of the specimen. Thermocouples were attached to top and bottom of specimen to monitor the specimen temperature during the test. The specimens were gripped in the furnace with the help of assembly.</p><p>The creep tests were conducted by using following procedure based on the standard practice ASTM E139-83. Load required to apply in pan is calculated as [<xref ref-type="bibr" rid="scirp.73666-ref17">17</xref>]</p><disp-formula id="scirp.73666-formula74"><graphic  xlink:href="http://html.scirp.org/file/73666x5.png"  xlink:type="simple"/></disp-formula><p>where, w―amount of load to be placed in pan, s―stress required, a―Cross section of specimen and r―Lever arm ratio.</p><p>The test was started with a preload of about 5% - 10% of the total load. Next, the test piece was heated. When the required temperature was reached, the sample was soaked for about 60 min. The load was applied without any jerk. The test load was applied along the test axis in such a manner that it minimized the bending and torsion of the test specimen. The WINCCS software provides computer automation of the entire creep test process. After completion of the test, the specimen dimensions were measured for calculation of percentage elongation and reduction of area. In stress rupture test, range of stresses applied was 120 to 600 MPa. Temperature was varied from 550˚C to 650˚C. For the present research work based on forging die working condition applied stress was 600 MPa and temperature was 650˚C.</p><p>High temperature wear testing was carried out on pin-on-disk DUCOM make tribometer. The samples shown in <xref ref-type="fig" rid="fig3">Figure 3</xref> were manufactured and given planned treatments as already described. Pins with two different types of material conditions (HT &amp; DCT32) were tested. This tribometer works on the Archimedes equation given below.</p><disp-formula id="scirp.73666-formula75"><graphic  xlink:href="http://html.scirp.org/file/73666x6.png"  xlink:type="simple"/></disp-formula><p>where, k―wear rate in mm<sup>3</sup>/Nm, ΔV―the worn out volume of material (mm<sup>3</sup>), F―normal force and L―sliding distance.</p><p>Disk and sample pins were cleaned with acetone to avoid any surface contamination. Fresh disk track was used for every new experiment. <xref ref-type="table" rid="table2">Table 2</xref> shows testing parameters which were used during wear testing. The results of wear testing reported in terms of weight loss of pins and wear rate. Weight loss of pins was calculated by taking weight of pin before and after testing whereas wear rate was calculated by using Archimedes equation as mentioned above.</p></sec></sec><sec id="s3"><title>3. Result and Discussion</title><sec id="s3_1"><title>3.1. Microstructural Analysis</title><p>The microstructure of harden and tempered (HT) sample shows needle type</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Wear test pin samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x7.png"/></fig><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Testing parameters used for wear testing</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  ></th><th align="center" valign="middle"  colspan="3"  >Parameters</th><th align="center" valign="middle" ></th></tr></thead><tr><td align="center" valign="middle" >Testing pin temperature</td><td align="center" valign="middle" >Load</td><td align="center" valign="middle" >Sliding velocity</td><td align="center" valign="middle" >Sliding distance</td></tr><tr><td align="center" valign="middle" >Value</td><td align="center" valign="middle" >400</td><td align="center" valign="middle" >150</td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1800</td></tr></tbody></table></table-wrap><p>tempered martensitic structure (<xref ref-type="fig" rid="fig4">Figure 4</xref>(a)) along with carbides of chromium, molybdenum and vanadium. The evolution of microstructure by execution of deep cryogenic treatment is shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>(b). It is observed that martensitic needles are finer in case of cryogenically treated samples.</p><p>The microstructure of conventional (HT) sample shows mainly primary and secondary carbides as shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>(a). In case of cryogenically treated</p><fig-group id="fig4"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> SEM images showing tempered martensitic structure (a) inconventional (HT) and cryogenically treated (DCT) sample (b).</title></caption><fig id ="fig4_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x8.png"/></fig><fig id ="fig4_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x9.png"/></fig></fig-group><fig-group id="fig5"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> SEM images showing carbides in conventional (a) and cryogenically treated (b) samples.</title></caption><fig id ="fig5_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x10.png"/></fig><fig id ="fig5_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x11.png"/></fig></fig-group><p>sample (<xref ref-type="fig" rid="fig5">Figure 5</xref>(b)), very fine carbides (tertiary carbides) are also present along with primary and secondary carbides which increase carbide density. The carbide density was measured by using image analysis software and it was 4.3% for conventional (HT) sample. Whereas it is increased 5.7% for cryogenically treated sample Cryogenic treatment induces residual compressive stresses which then released during soft tempering creating nucleation sites for fine carbides [<xref ref-type="bibr" rid="scirp.73666-ref12">12</xref>]. Smaller carbide size and their more uniform distribution were also observed in case of deep cryogenically treated (DCT only) sample. The above findings are in good agreement with the published literature [<xref ref-type="bibr" rid="scirp.73666-ref13">13</xref>].</p><p>Deep cryogenic treatment also transforms retained austenite to martensite. The XRD analysis of conventional (HT) and deep cryogenically treated samples do not show presence of any retained austenite. Though conventional harden and tempered sample expected to have some amount of retained austenite (RA), but this amount is very low (below 4%) and it is difficult to measure. Almost complete transformation of austenite to martensite during hardening and tempering may be due to oil quenching used during hardening of this tool steel. Though small amount of RA was there after conventional treatment, DCT ensures complete transformation of retained austenite to martensite [<xref ref-type="bibr" rid="scirp.73666-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.73666-ref4">4</xref>].</p></sec><sec id="s3_2"><title>3.2. Mechanical Properties</title><p>The hardness and impact toughness of conventionally (HT) and cryogenically (DCT32) treated samples are presented in <xref ref-type="table" rid="table3">Table 3</xref>. Cryogenically treated sample resulted in slightly higher hardness as compared to conventional sample which may be due to increased carbide density and complete transformation of retained austenite to martensite. Moreover additional microstructural modifications, like finer martensitic structure, more uniform distribution of carbides and martensitic needles significantly increases impact toughness of cryogenically treated samples.</p></sec><sec id="s3_3"><title>3.3. Stress Rupture Performance</title><p>The equations Stress rupture performance of Conventional heat treatment and deep cryogenic treatment (DCT) is given in <xref ref-type="fig" rid="fig6">Figure 6</xref>. This shows significant impact of deep cryogenic heat treatment on rupture time. Rupture time for cryogenically treated sample is increased by 11.49% compared to conventionally heat treated sample. It may note that rise in rupture time could to attributed to increase in small sized tertiary carbides and their more homogeneous distribution.</p></sec><sec id="s3_4"><title>3.4. Wear Performance</title><p>The wear performance of tool steels is very complex phenomenon and it not only depends on the hardness but also on the microstructure, process variables and properties of sliding materials [<xref ref-type="bibr" rid="scirp.73666-ref17">17</xref>]. In the present research work, wear performance in terms of wear rate for heat treated and deep cryogenically treated at</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Mechanical properties of HT and DCT samples</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Sample treatment condition</th><th align="center" valign="middle" >Hardness (HRC)</th><th align="center" valign="middle" >Impact toughness (J)</th></tr></thead><tr><td align="center" valign="middle" >HT</td><td align="center" valign="middle" >50.1</td><td align="center" valign="middle" >16.2</td></tr><tr><td align="center" valign="middle" >DCT</td><td align="center" valign="middle" >52.3</td><td align="center" valign="middle" >19.1</td></tr></tbody></table></table-wrap><p>32 hours (DCT 32) material conditions is given in <xref ref-type="fig" rid="fig7">Figure 7</xref>. The wear rate of cryogenically treated samples (DCT32) are significantly lower than conventional harden and tempered (HT) samples. It is clearly due to formation of tertiary carbides and their increased density during deep cryogenic treatment. Deep cryogenically treated sample reduces wear rate by 32% as compared to conventional harden and tempered (HT) sample.</p></sec></sec><sec id="s4"><title>4. Conclusions</title><p>To summarize, this study explored the effect of deep cryogenic treatment on AISI H-13 tool steel and analyzed mechanisms behind it. The following conclusions can be drawn from the work:</p><p>Deep cryogenic treatment (DCT) causes microstructural changes like fine martensitic structure, increase in carbide density and their uniform distribution which improves hardness impact toughness, wear and stress rupture property as compared to conventional harden and tempered (HT) samples.</p><p>Stress rupture time increased by 11.49% as compared to heat treated samples.</p><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Rupture time (Hrs) for heat treated and cryogenically treated sample</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x12.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Wear rate for different conditions of sample</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/73666x13.png"/></fig><p>Impact toughness of cryogenically treated samples is improved by 17.9.</p><p>Reduction in wear rate by 32% is observed as compared to conventional harden and tempered sample.</p></sec><sec id="s5"><title>Acknowledgements</title><p>The authors gratefully acknowledge the extended support provided to this work by KCTI (Kalyani Centre for Technology and Innovation) for providing financial funding, laboratory and library facilities. The authors also acknowledge the support provided by Bharat Forge Ltd., Pune and DSIR (Department of Scientific and Industrial Research), Govt. of India. Finally, the authors would like to express special thanks and gratitude to review committee and top management of Bharat Forge Ltd for granting the permission to publish/present the research work. The authors also wish to place their sincere thanks to department of metallurgy, college of engineering Pune (COEP) for providing experimentation facility.</p></sec><sec id="s6"><title>Cite this paper</title><p>Bhawar, V., Khot, S., Kattire, P., Mehta, M. and Singh, R. (2017) Influence of Deep Cryogenic Treatment (DCT) on Thermo Mechanical Performance of AISI H13 Tool Steel. Journal of Materials Science and Chemical Engineering, 5, 91-101. http://dx.doi.org/10.4236/msce.2017.51013</p></sec></body><back><ref-list><title>References</title><ref id="scirp.73666-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Naravade, R.H., Gujar, U.N. and Kharde, R.R. (2012) Optimization of Cryogenic Treatment on Wear Behaviour of D6 Tool Steel by Using DOE/RSM. International Journal of Engineering and Advanced Technology (IJEAT), 2.</mixed-citation></ref><ref id="scirp.73666-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Rout, S., Behera, A. and Mishra, S.C. Assurance of Quality Improvement for Tool Steel by Cryo-Processing. Advances in Mechanics and Materials.</mixed-citation></ref><ref id="scirp.73666-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Behera, A. and Mishra, S.C. (2012) Comparative Study of Cryo-Treated Steel. International Journal of Scientific &amp; Technology Research, 1.</mixed-citation></ref><ref id="scirp.73666-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">da Silva, F.J., Franco, S.D., Machado, A.R., Ezugwu, E.O. and Souza Jr., A.M. (2006) Performance of Cryogenically Treated HSS Tools. Wear, 261.  
https://doi.org/10.1016/j.wear.2006.01.017</mixed-citation></ref><ref id="scirp.73666-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Chaphalkar, S.P. and Lele, M.M. Effect of the Soaking Period in Deep Cryogenic Treatment on Tool Life and Wear Resistance of Tool Steel.</mixed-citation></ref><ref id="scirp.73666-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Dhokey, N.B., Dandawate, J.V. and Rawat, R. (2013) Effect of Cryosoaking Time on Transition in Wear Mechanism of M2 Tool Steel. Hindawi Publishing Corporation, ISRN Tribolo-gy.</mixed-citation></ref><ref id="scirp.73666-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Candane1, D., Alagumurthi, N. and Palaniradja, K. (2013) Effect of Cryogenic Treatment on Microstructure and Wear Characteristics of AISI M35 HSS. International Journal of Materials Science and Applications.</mixed-citation></ref><ref id="scirp.73666-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Dhokey, N.B., Hake, A., Kadu, S., Bhoskar, I. and Dey, G.K. (2013) Influence of Cryoprocessing on Mechanism of Carbide Development in Cobalt-Bearing High- Speed Steel (M35). Metallurgical and Materials Transactions A, 44A.</mixed-citation></ref><ref id="scirp.73666-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Akhbarizadeh, A., Shafyei, A. and Golozar, M.A. (2009) Effects of Cryogenic Treatment on Wear Behavior of D6 Tool Steel. Materials and Design, 30, 3259-3264.  
https://doi.org/10.1016/j.matdes.2008.11.016</mixed-citation></ref><ref id="scirp.73666-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Dhokey, N.B., Hake, A.R., Thavale, V.T., Gite, R. and Batheja, R. (2014) Micro-structure and Mechanical Properties of Cryotreated SAE8620 and D3 Steels. Current Advances in Materials Sciences Research (CAMSR), 1.</mixed-citation></ref><ref id="scirp.73666-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Chaudhari, S.B., Shekhawat, S.P. and Kushwaha, A.S. (2012) Advanced Technology of Cryoprocessing for the Enhancement of Tool Material Machining Characteristics: A Review. International Journal of Emerging Technology and Advanced Engineering, 2.</mixed-citation></ref><ref id="scirp.73666-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Chaphalkar, S.P. and Lele, M.M. Effect of the Soaking Period in Deep Cryogenic Treatment on Tool Life and Wear Resistance of Tool Steel.</mixed-citation></ref><ref id="scirp.73666-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Koneshlou, M., Asl, K.M. and Khomamizadeh, F. (2011) Effect of Cryogenic Treatment on Microstructure, Mechanical and Wear Behaviors of AISI H13 Hot Work Tool Steel. Cryogenics, 51.</mixed-citation></ref><ref id="scirp.73666-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Latas, Z., Ciski, A. and Suchmann, P. (2006) Cryogenic Treatment and Combination of Nitriding and Cryogenic Treatment of Hot Forging Tools. 4th WSEAS Int. Conf. on Heat Transfer, Thermal Engineering and Environment, Elounda, 21-23 August 2006.</mixed-citation></ref><ref id="scirp.73666-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Perez, M., Rodriguez, C. and Belzunce, F.J. (2014) The Use of Cryogenic Thermal Treatments to Increase the Fracture Toughness of a Hot Work Tool Steel Used to Make Forging Dies. 20th European Conference on Fracture (ECF20).  
https://doi.org/10.1016/j.mspro.2014.06.100</mixed-citation></ref><ref id="scirp.73666-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">&amp;Ccedil;iek, A., Kara, F., Kivak, T. and Ekici, E. (2013) Evaluation of Machinability of Hardened and Cryo-Treated AISI H13 Hot Work Tool Steel with Ceramic Inserts. Int. Journal of Refractory Metals and Hard Mate-rials.</mixed-citation></ref><ref id="scirp.73666-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Bhawar, V., Khot, S., Kattire, P., Mehta, M. and Singh, R.K.P. Effect of Deep Cryogenic Treatment (DCT) on AISI H13 Tool Steel. Proceedings of the 28th ASM Heat Treating Society Conference.</mixed-citation></ref></ref-list></back></article>