<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AM</journal-id><journal-title-group><journal-title>Applied Mathematics</journal-title></journal-title-group><issn pub-type="epub">2152-7385</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/am.2016.717177</article-id><article-id pub-id-type="publisher-id">AM-72195</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Application of Simplex Method in the Radiotherapy Treatment
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Thais</surname><given-names>R. Salvador</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Silvia</surname><given-names>M. S. Carvalho</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mayk</surname><given-names>V. Coelho</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Federal University of Alfenas-MG, Po&amp;amp;ccedil;os de Caldas, Minas Gerais, Brazil</addr-line></aff><aff id="aff1"><addr-line>DFQM, Federal University of S&amp;amp;atilde;o Carlos, Sorocaba, S&amp;amp;atilde;o Paulo, Brazil</addr-line></aff><pub-date pub-type="epub"><day>14</day><month>11</month><year>2016</year></pub-date><volume>07</volume><issue>17</issue><fpage>2229</fpage><lpage>2240</lpage><history><date date-type="received"><day>September</day>	<month>17,</month>	<year>2016</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>November</month>	<year>20,</year>	</date><date date-type="accepted"><day>November</day>	<month>23,</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  This work presents an application of the Simplex Method for solving an optimal planning problem for cancer treatment by radiotherapy. Linear Programming can aid the optimal planning for radiation therapy, where the concern is to apply a high enough radiation in the tumor while saving significantly healthy regions or critical organs.
 
</p></abstract><kwd-group><kwd>Linear Programming</kwd><kwd> Simplex Method</kwd><kwd> Radiotherapy</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Among the problems of global health, cancer has become one of the main subjects of research for different fields of knowledge. Many of these researches are conducted with the goal of developing and evaluating new forms of therapy or just new methodologies or treatment protocols. As there is a wide variety of algorithms for tomographic reconstruction and absorbed dose calculation in radiation therapy applications involving various mathematical techniques have been proposed and are still constantly improved [<xref ref-type="bibr" rid="scirp.72195-ref1">1</xref>] .</p><p>From a mathematical point of view, the challenge is to deliver a high radiation dose to the tumor, enough to eliminate them, and simultaneously minimize radiation in the surrounding regions, composed of healthy tissue, while minimizing the complications in these regions.</p><p>Among these techniques, linear programming stands out for its intense and wide application and the results obtained are considered promising. The objective of treatment is to eliminate tumor cells by radiation, and at the same time it seeks to prevent the destruction of surrounding healthy cells also affected by radiation. For planning the treatment with radiosurgery computerized tomography images are scanned and merged with magnetic resonance images obtained previously. From these images critical structures and tumor are located and then many computations may be performed to determine three-dimensional isocenters, isodose curves, dose to be prescribed, position, number and its weight conformal isocentric fields, among others. Such plan is prepared by the surgical team in order to obtain an adequate and optimal treatment for each case.</p><p>The treatment plans are commonly based on the desired dose levels for specific types of tumors and organs at risk in the irradiated region. These levels’ dose is chosen so that high probability of cure is achieved, while the likelihood of complications in any organ is minimal risk. The aim of this paper is to show the optimal planning in radiotherapy looking for an optimal solution using the Simplex Method and its comparison with Interior Points Methods.</p></sec><sec id="s2"><title>2. Linear Programming in Radiotherapy</title><p>In recent decades, the impact of cancer in society got large attention, becoming a global concern, and in Brazil one of the top positions in the macro-regions mortality rates, along with the diseases of the circulatory system, external causes, among others. Cancer is a disease that begins when a genetic mutation in the DNA of the cell, where the control mechanism of normal tissue growth is changed. The methods for cancer treatment are: surgery, radiotherapy and chemotherapy.</p><p>The radiotherapy treatment aims elimination of cancerous cells through radiation or relief of symptoms and at the same time seeking to avoid destruction of surrounding healthy cells also affected by radiation. From a mathematical point of view, the challenge is to deliver a high dosage radiation into the tumor, sufficient for eliminating and stopping the growth of tumor cells, whilst minimizing the radiation neighboring regions composed of healthy tissue, while minimizing complications in those regions which are often critical.</p><p>At the beginning of the use of radiotherapy, was applied high doses of radiation, as well as the patient be able to afford. The dose constraint was generally established the tolerance of the skin [<xref ref-type="bibr" rid="scirp.72195-ref2">2</xref>] . There are two main types of radiation: brachytherapy and teletherapy. Give yourself will focus in this work to the second type. In this case, neither the radiation source nor device that emits, are in direct contact with the patient. Therefore, the radiation reaches beyond the tumor all organs and tissues that are in the way. In the brachytherapy radiation source is placed inside the patient in the region that would receive treatment. It is a kind of non-permanent radioactive implant [<xref ref-type="bibr" rid="scirp.72195-ref3">3</xref>] . Usually for the treatment using a beam with rectangular form, which passes through different types of patient body tissues, and depending on the attenuation and the depth of tissue, a large amount of energy is deposited at various points within the body. For radiotherapy treatment should take into account the depth dose distribution in the central axis and characterizing the radiation beam. To represent and to have the concept of the dose distribution and absorption throughout the volume and makes up the isodose curve, which are lines representing points of the same dose in a given arrangement of radiation beams. For the mathematical calculation, they are used clinical tumor data for each patient treated. These calculations can be performed by mathematical models through linear programming.</p>Mathematical Formulation<p>When cancer is diagnosed and there are medical indications for treatment by radiotherapy, various tests are performed on the patient, in order to learn about the location, form and tumor volume, as well as critical tissues in the region to be treated. The use of computerized tomography exams for reliable data collection and in the radiosurgery is required along with a computed tomography an magnetic resonance exam.</p><p>Based on these data, the dose to be received in the tumor and the volume to be irradiated may be prescribed by the doctor radiotherapist. Together with a physical, the radiation oncologist can then by the analysis of isodose curves can define the best type of treatment and the technique to be used. After obtaining the images by computed tomography or magnetic resonance imaging, the minimum dose to be applied to the tumor is prescribed as the maximum doses that critics and healthy tissue can receive. Through these images, it makes the selection of the anatomical structures of interest.</p><p>On the images obtained, the structures of interest can then be mapped (and critical lesion tissue) through a pixelation. Each pixel is related to an electron density and receives specific coordinates (i,j), which will be used in the creation of conformational planning or 3D treatment planning, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><p>To illustrate, suppose a dimensional image m &#215; n where each element’s image is called pixel representing a part of the human body. Also, consider que each angle is composed of sub-rays. Modern processing systems are capable of performing complex combinations between these sub-beams. The number of angles is fixed such that are considered k angles locations to issue the main beam Radiation. Each one containing <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x2.png" xlink:type="simple"/></inline-formula> sub-beams. Modern processing systems are able to perform combinations among these sub-beams to use them over a full arc, making planning using <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x3.png" xlink:type="simple"/></inline-formula> sub-beams. This decomposition of the radiation beams is based on the theoretical and practical foundations of radiotherapy with modulated intensity. The geometry of a model using elementary beams, where<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x4.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x5.png" xlink:type="simple"/></inline-formula>and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x6.png" xlink:type="simple"/></inline-formula> is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The inter-</p><p>vals between the angles <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x7.png" xlink:type="simple"/></inline-formula> and the initial angle is (usually) zero.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Image in pixels</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/12-7403397x8.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Geometry of an image</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/12-7403397x9.png"/></fig><p>In the treatment planning, once defined the coordinates (i,j) of pixels, with<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x10.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x11.png" xlink:type="simple"/></inline-formula>, one computes the total dose <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x12.png" xlink:type="simple"/></inline-formula> being received by the patient in each pixel coordinates (i,j). Thus, one can estimate the dose to be received in each patient’s tissue (critical, healthy and tumor), the area to be treated worrying not to exceed the dose supported by healthy and critical tissues and a dose sufficient enough to eliminate the tumor.</p><p>This model can be represented by the following:</p><disp-formula id="scirp.72195-formula98"><label>(1.0)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x13.png"  xlink:type="simple"/></disp-formula><p>where,</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x14.png" xlink:type="simple"/></inline-formula>represents the total dose received by the patient in position (i,j);</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x15.png" xlink:type="simple"/></inline-formula>represents the nominal dosage issued by the radius p in position (i,j);</p><p>・ w represents the weight of the dosage emitted by beams;</p><p>・ l represents the minimum dose to be received by the tumor;</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x16.png" xlink:type="simple"/></inline-formula>represents the subset of positions where the tumor is located;</p><p>・ n represents the number of rays;</p><p>・ m represents the total number of pixels.</p><p>It is possible to formulate a model with weights in each region of the patient privileged or penalize some areas the dosing quantity to be received. Given the delineation of structures, the treatment plan should be developed in order to manage the radiation dose on the tumor, thus seeking the homogeneity of the treatment plan, according to the determination of the dose prescription of regions of interest.</p><p>Defining the following subsets:</p><p>・ R represents the subset of positions where critical tissue (healthy) or critical framework;</p><p>・ N represents the subset of positions where the other healthy tissues.</p><p>It is possible to formulate a model with weights in each region of the patient privileging or penalizing some areas where the dosing quantity is received.</p><p>Given the delineation of structures, the treatment plan should be developed in order to manage the radiation dose to the tumor, thus seeking the homogeneity of the treatment plan, according to the determination of the dose prescription of regions of interest.</p><p>Holder [<xref ref-type="bibr" rid="scirp.72195-ref4">4</xref>] formulates some models of Linear Programming by weightings in each region of the patient’s image, considering or privileging the type of tissue to be exposed to radiation doses.</p><p>As <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x17.png" xlink:type="simple"/></inline-formula> the dose over the i-th subfeixe, to <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x18.png" xlink:type="simple"/></inline-formula> a-th angle to <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x19.png" xlink:type="simple"/></inline-formula> <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x20.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x21.png" xlink:type="simple"/></inline-formula> the distance between the source positioned at an angle to sending subfeixe i (de dose<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x22.png" xlink:type="simple"/></inline-formula>) and pixel p. The dose deposition in the pixel p due i-th subfeixe of the a-th angle <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x19.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x22.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x23.png" xlink:type="simple"/></inline-formula> is defined as:</p><disp-formula id="scirp.72195-formula99"><label>(1.1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x24.png"  xlink:type="simple"/></disp-formula><p>The term S represents the geometric area of pixel p which receives the dose<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x25.png" xlink:type="simple"/></inline-formula>. With the component <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x25.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x26.png" xlink:type="simple"/></inline-formula> may be constructed the dose deposition of matrix A, where the rows in A are indexed by p and the columns are indexed by<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x25.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x26.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x27.png" xlink:type="simple"/></inline-formula>, as shown in the matrix (1.2), thus the matrix A has dimension<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x25.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x26.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x27.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x28.png" xlink:type="simple"/></inline-formula>.</p><disp-formula id="scirp.72195-formula100"><label>(1.2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x29.png"  xlink:type="simple"/></disp-formula><p>Most research has used optimization models with linear constraints, with one of the two most obvious objective functions, maximizing the dose to the tumor and minimize the dose to the critical structure. Since this often leads maximization at high doses, other studies seek to maximize the minimum dose of the tumor or reduce the maximum dose of critical structure [<xref ref-type="bibr" rid="scirp.72195-ref5">5</xref>] .</p><p>The goals listed below indicate that this problem has many parameters to consider in deciding what would be desirable for a treatment plan:</p><p>・ Transmitting a uniformly lethal dose in the tumor region;</p><p>・ Transmitting radiation as small as possible in critical structure;</p><p>・ Obtain a total dose as small as possible;</p><p>・ Reducing the frequency of high doses outside the region of the tumor;</p><p>・ Controlling the number of rays used in the treatment plan.</p><p>In search of uniform doses, Holder proposed a linear optimization model to assist in the optimal planning of radio surgery. This model has been widely cited in the literature by presenting good results in terms of conformal plans. So we opted for the study and implementation of this model, which will be discussed below.</p><p>Consider, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x30.png" xlink:type="simple"/></inline-formula>tumor pixel number, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x31.png" xlink:type="simple"/></inline-formula>the number of pixels of the critical structure and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x31.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x32.png" xlink:type="simple"/></inline-formula> the number of pixels of healthy tissue. Therefore the total number of pixels is given by<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x30.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x31.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x32.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x33.png" xlink:type="simple"/></inline-formula>. Thus, in the model of Holder, the dose deposition matrix is divided into three parts:</p><disp-formula id="scirp.72195-formula101"><label>(1.3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x34.png"  xlink:type="simple"/></disp-formula><p>The rows of the dose deposition matrix are rearranged so that T is related to the set of pixels comprising the lesion or tumor, C to pixel set included the critical tissue or organs at risk and G to the pixel set of remaining healthy tissue.</p><p>Thus, the sectional image of computed tomography is converted into an array of pixels, which are classified to represent tumor and non-tumor regions. Due the division into pixels, the model that will be presented, the prescription dose is given in the form of vector and defined by four boundaries, with the following notation:</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x35.png" xlink:type="simple"/></inline-formula>represents the upper limit vector to radiation in the tumor (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x35.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x36.png" xlink:type="simple"/></inline-formula>);</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x37.png" xlink:type="simple"/></inline-formula>represents the lower limit vector to the tumor radiation (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x37.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x38.png" xlink:type="simple"/></inline-formula>);</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x39.png" xlink:type="simple"/></inline-formula>represents the upper limit vector for radiation in the critical structure (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x39.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x40.png" xlink:type="simple"/></inline-formula>);</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x41.png" xlink:type="simple"/></inline-formula>represents the upper limit vector to radiation in the remaining healthy tissue (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x41.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x42.png" xlink:type="simple"/></inline-formula>).</p><p>Obviously <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x43.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x43.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x44.png" xlink:type="simple"/></inline-formula> hold. If an uniform lethal dose is transmit ted to the tumor, the upper and lower limit to the tumor pixels are obtained through the established goals.</p><p>Assuming that the targets set for a cell are<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula>, the values <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x46.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x46.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x47.png" xlink:type="simple"/></inline-formula> they are generally (1 + e) <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x46.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x47.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x48.png" xlink:type="simple"/></inline-formula> and (1 − e)<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x46.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x47.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x48.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x49.png" xlink:type="simple"/></inline-formula>, respectively, where <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x46.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x47.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x48.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x49.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x50.png" xlink:type="simple"/></inline-formula> is the percentage of variation for tumor strength and uniformity is termed the tumor level. Typical values <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x45.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x46.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x47.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x48.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x49.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x50.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x51.png" xlink:type="simple"/></inline-formula> are found in the literature varying from 0.02 to 0.15.</p><p>The vector <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x52.png" xlink:type="simple"/></inline-formula> represents the largest amount of radiation allowed for any pixel (healthy). Generally healthy tissues should not receive more than 10% of the dose established for the tumor. That is,<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x52.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x53.png" xlink:type="simple"/></inline-formula>. The rows of dose deposition array are rearranged in row a representing cancer regions critical structures and the remaining healthy tissue. This reordering is represented by the<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x52.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x54.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x52.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x54.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x55.png" xlink:type="simple"/></inline-formula>and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x52.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x53.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x54.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x55.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x56.png" xlink:type="simple"/></inline-formula> as shown in (1.3).</p><p>The sub-beams that do not reach the tumor are removed by the elimination of the columns that have the zero vector in the corresponding column of submatrix<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x57.png" xlink:type="simple"/></inline-formula>. Thus, without loss of generality let us assume that the <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x57.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x58.png" xlink:type="simple"/></inline-formula> matrix does not have null columns. Therefore, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x57.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x58.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x59.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x57.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x58.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x59.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x60.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x57.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x58.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x59.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x60.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x61.png" xlink:type="simple"/></inline-formula>and<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x57.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x58.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x59.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x60.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x61.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x62.png" xlink:type="simple"/></inline-formula>.</p></sec><sec id="s3"><title>3. Linear Optimization Problem</title><p>The model proposed by [<xref ref-type="bibr" rid="scirp.72195-ref4">4</xref>] allows a number of constraints on the amount of limitation of the dose in each tissue type. The objective function is represented by the weighted sum of three goals:</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x63.png" xlink:type="simple"/></inline-formula>, which measures how close the minimum dose the found plan apply in the tumor region;</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x64.png" xlink:type="simple"/></inline-formula>, which measuring the amount of radiation received by the prescribed critical region;</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x65.png" xlink:type="simple"/></inline-formula>, which measuring the amount of radiation prescribed gin other healthy tissues.</p><p>The positive scalar w weight the importance of formulating a plan to get the minimum dose in the tumor region, i.e., large values of w make <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x66.png" xlink:type="simple"/></inline-formula> to be as small as possible. It would be desirable if there were a finite value for <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x66.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x67.png" xlink:type="simple"/></inline-formula> such that the optimal value of the component <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x66.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x67.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x68.png" xlink:type="simple"/></inline-formula> were zero which would ensure the tumor receives as much radiation level as possible.</p><p>The proposed model can be represented as follows:</p><disp-formula id="scirp.72195-formula102"><label>(1.4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x69.png"  xlink:type="simple"/></disp-formula><p>where,</p><p>・ w: positive scalar;</p><p>・ x: dose of sub-beams entering the image to reach the pixel p, (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x70.png" xlink:type="simple"/></inline-formula>);</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x71.png" xlink:type="simple"/></inline-formula>;</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x72.png" xlink:type="simple"/></inline-formula>;</p><p>・ <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x73.png" xlink:type="simple"/></inline-formula>.</p><p>The constraints<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x74.png" xlink:type="simple"/></inline-formula>, and<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x74.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x75.png" xlink:type="simple"/></inline-formula>, are called elastic constraints, since their limits may vary according to the vectors t, c and g, respectively.</p><p>The matrices <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x76.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x76.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x77.png" xlink:type="simple"/></inline-formula> define how to measure elasticity, and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x76.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x77.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x78.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x76.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x77.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x78.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x79.png" xlink:type="simple"/></inline-formula> control the penalty or reward relative to elasticity.</p><p>Fixed values <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x80.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x80.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x81.png" xlink:type="simple"/></inline-formula> define a set of elastic functions. And these are incorporated for the following reasons:</p><p>1) The elastic constraint ensures that a set of elastic functions is always strictly feasible;</p><p>2) The difference of the limits on the elastic functions allow us to incorporate different treatment goals.</p><p>As previously discussed, the model (1.4) is a linear programming problem and can be solved by the simplex method. To solve this problem, means determining <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x82.png" xlink:type="simple"/></inline-formula> and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x82.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x83.png" xlink:type="simple"/></inline-formula> that optimize the objective function and achieve the goals set the best way possible.</p><p>Thus, with the optimal dose of vector x is possible to compute the total dose of radiation, or total for each pixel. Given the optimal dose distribution in tissues it is possible to construct isodose curves.</p></sec><sec id="s4"><title>4. Simplex Method Applied to the Treatment Model for Radiotherapy</title><p>As the image is in pixels, the dose limits should be divided by the number of pixels of the respective bodies, to ensure the uniformity of the dose [<xref ref-type="bibr" rid="scirp.72195-ref6">6</xref>] . Therefore, the objective</p><p>function, the values dose limits will be <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x84.png" xlink:type="simple"/></inline-formula> and<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x84.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x85.png" xlink:type="simple"/></inline-formula>, where</p><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x86.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x86.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x87.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x86.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x87.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x88.png" xlink:type="simple"/></inline-formula>and e is unit vector.</p><p>Supposing, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x89.png" xlink:type="simple"/></inline-formula>, and replacing bounded constraint<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x89.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x90.png" xlink:type="simple"/></inline-formula>, as L = I, U<sub>c</sub> = I and<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x89.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x90.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x91.png" xlink:type="simple"/></inline-formula>, we obtain following problem:</p><disp-formula id="scirp.72195-formula103"><label>(1.5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x92.png"  xlink:type="simple"/></disp-formula><p>Thus, we obtain the following constraint matrix:</p><disp-formula id="scirp.72195-formula104"><label>(1.6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/12-7403397x93.png"  xlink:type="simple"/></disp-formula></sec><sec id="s5"><title>5. Computational Results</title><p>This section will present and discuss some results obtained in the computational implementation of the mathematical model (1.4), aiming to help in optimal radiotherapy planning. The problem was solved in a Microcomputer-macbook pro, 2.5 GHz processor, i5, 4 GB memory, 1600 MHz, DDR3.</p><p>Following the described methodology, initially the cancer is diagnosed and indicated with radiation therapy. Thereafter, they are carried tomography computed or tumor sizing and location of the regions of interest (tumor, healthy and critical). Thus, the doctor determines the dose to be applied in the tumor (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x94.png" xlink:type="simple"/></inline-formula>).</p><p>The Image tomography and divided into pixels and are obtained as Geometric Positions of pixels locations relating to tissues Critics, healthy and tumor to be used in doses of Matrix Construction <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x95.png" xlink:type="simple"/></inline-formula> as defined in (1.3).</p><p>For the computational experiment, it is considered hypothetically, that the patient has a spherical tumor with a diameter of 15 mm, surrounded by critical tissue, exemplifying a spinal cord tumor, where there is difficulty in planning due to cancer was fully surrounded by a critical structure [<xref ref-type="bibr" rid="scirp.72195-ref7">7</xref>] .</p><p>In this case, it has been indicated a radiotherapy treatment with tumor dose of 80 Gy, where Gy represents the amount of absorbed ionizing radiation energy (or dose) for mass unit (1 Gray (Gy) = 1 J/kg). It was considered a percentage change<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x96.png" xlink:type="simple"/></inline-formula>, and the critical structure can accommodate up to 40 Gy and healthy at most 60 Gy. As the positive scalar (w) considering the importance that the tumor receives the dose minimum, two values was considered for comparison, namely <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x96.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x97.png" xlink:type="simple"/></inline-formula> and<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x96.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x97.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x98.png" xlink:type="simple"/></inline-formula>. Other bounds are given on the <xref ref-type="table" rid="table1">Table 1</xref>.</p><p>The considered lesion contains four pixels (2 &#215; 2 pixels), the critical tissue around the lesion comprises 16 pixels (4 &#215; 4 pixels). The developed planning system uses a grid</p><p>of 16 &#215; 16 pixels, with 4 angles from 0, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x99.png" xlink:type="simple"/></inline-formula>, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x99.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x100.png" xlink:type="simple"/></inline-formula>and <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x99.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x100.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/12-7403397x101.png" xlink:type="simple"/></inline-formula> degrees, where each beam is composed by six sub-beams.</p><p>To improve the computational performance, we have considered only the region that tends to form hot pixels, which are pixels that receive radiation being considered healthy structure with 36 pixels. The pixels that will not receive radiation are called cold pixels [<xref ref-type="bibr" rid="scirp.72195-ref8">8</xref>] .</p><p>The 1.5 objective function is the sum of three goals: to achieve a high enough dosage to eliminate the cancer and not exceed the maximum dose in healthy tissues and critical. The <xref ref-type="table" rid="table2">Table 2</xref> summarizes the numerical results obtained on the value of the objective function, number of iterations and run time in seconds.</p><p>Analyzing the results in <xref ref-type="table" rid="table2">Table 2</xref>, we can see that the minimized function achieved a very low value, which is a good conformation of isodose curves, thus ensuring a safe</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Values in the model relative the doses</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Used Value</th><th align="center" valign="middle" >Gy</th></tr></thead><tr><td align="center" valign="middle" >u<sub>t </sub></td><td align="center" valign="middle" >81.6</td></tr><tr><td align="center" valign="middle" >l<sub>t </sub></td><td align="center" valign="middle" >78.4</td></tr><tr><td align="center" valign="middle" >u<sub>c </sub></td><td align="center" valign="middle" >40</td></tr><tr><td align="center" valign="middle" >u<sub>g </sub></td><td align="center" valign="middle" >60</td></tr><tr><td align="center" valign="middle" >t<sub>g </sub></td><td align="center" valign="middle" >80</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Numerical results in the objective function</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Variables</th><th align="center" valign="middle" >W = 0.1</th><th align="center" valign="middle" >W = 40</th></tr></thead><tr><td align="center" valign="middle" >Objective function value</td><td align="center" valign="middle" >2.9553 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >2.9800 &#215; 10<sup>−6 </sup></td></tr><tr><td align="center" valign="middle" >Iteration</td><td align="center" valign="middle" >38</td><td align="center" valign="middle" >38</td></tr><tr><td align="center" valign="middle" >Time</td><td align="center" valign="middle" >0.010718 s</td><td align="center" valign="middle" >0.011471 s</td></tr><tr><td align="center" valign="middle" >Tolerance</td><td align="center" valign="middle" >1.0 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >1.0 &#215; 10<sup>−6 </sup></td></tr><tr><td align="center" valign="middle" >Excess dose in the tumor</td><td align="center" valign="middle" >0.1232 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >0.1133 &#215; 10<sup>−6 </sup></td></tr><tr><td align="center" valign="middle" >Excess dose in critical tissue</td><td align="center" valign="middle" >0.1142 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >0.1242 &#215; 10<sup>−6 </sup></td></tr><tr><td align="center" valign="middle" >Excess dose in healthy tissue</td><td align="center" valign="middle" >0.0045 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >0.0045 &#215; 10<sup>−6 </sup></td></tr></tbody></table></table-wrap><p>treatment. The dose of excesses in critical and healthy regions and the dose deficit in the tumor region is almost zero, thus showing that the tumor received the dose required for elimination and the dose limit allowed for other regions was not exceeded.</p><p>The weight w decides the importance of dose uniformity in the tumor. As we can see the results, if w is small, indicates that finding a treatment plan reach the dose lower limit of the tumor is not so important. Increasing w increases the chances that the treatment plan to reach an uniform dose and tumor need. Thus, higher values for w force excess dose in the tumor to be as minimal as possible.</p>Compared to the Interior Point Methods<p>At this moment, we compare the dual simplex method with interior points methods to three real problems.</p><p>Analysis report on the results obtained:</p><p>In <xref ref-type="table" rid="table3">Table 3</xref> and <xref ref-type="table" rid="table4">Table 4</xref> the computational time for the dual simplex method is slightly less when compared to the interior point method, unlike what happens with the larger problem 1.5 which is easily explained as the interior point method always has good results for large problems [<xref ref-type="bibr" rid="scirp.72195-ref9">9</xref>] , which does not occur with the Simplex method. In all other aspects the methods have the same performance.</p><p>In <xref ref-type="table" rid="table5">Table 5</xref> the computational time for the interior point methods is smaller compared to the dual simplex method and this is common with increasing the dimension of the problem, since it is a robust method and very used in large problems.</p></sec><sec id="s6"><title>6. Conclusions</title><p>This work presented an application of the simplex method in a cancer treatment plan for radiotherapy and a model based on linear programming for assistance in optimal planning. It can be seen that the mathematical model used in this paper can be a tool of great importance in the construction of optimized treatment plans; it provides a set of optimal solutions, which related to the treatment, may enable a high quality therapy [<xref ref-type="bibr" rid="scirp.72195-ref10">10</xref>] .</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Problem 342 Pixels</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Method</th><th align="center" valign="middle" >Dual Simplex</th><th align="center" valign="middle" >IPM</th></tr></thead><tr><td align="center" valign="middle" >Iteration</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" >12</td></tr><tr><td align="center" valign="middle" >Time</td><td align="center" valign="middle" >4.535522 &#215; 10<sup>−1</sup> s<sup> </sup></td><td align="center" valign="middle" >2.307250 s<sup> </sup></td></tr><tr><td align="center" valign="middle" >Function objective</td><td align="center" valign="middle" >3.042952 &#215; 10<sup>−9 </sup></td><td align="center" valign="middle" >3.042952 &#215; 10<sup>−9</sup></td></tr><tr><td align="center" valign="middle" >Excess dose in the tumor</td><td align="center" valign="middle" >4.153469 &#215; 10<sup>−5 </sup></td><td align="center" valign="middle" >4.153469 &#215; 10<sup>−5</sup></td></tr><tr><td align="center" valign="middle" >Excess dose un critical tissue</td><td align="center" valign="middle" >7.304035 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >7.304035 &#215; 10<sup>−6</sup></td></tr><tr><td align="center" valign="middle" >Excess dose in healthy tissue</td><td align="center" valign="middle" >9.863899 &#215; 10<sup>−8 </sup></td><td align="center" valign="middle" >9.863899 &#215; 10<sup>−8</sup></td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Problem 747 Pixels</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Method</th><th align="center" valign="middle" >Dual Simplex</th><th align="center" valign="middle" >IPM</th></tr></thead><tr><td align="center" valign="middle" >Iteration</td><td align="center" valign="middle" >13</td><td align="center" valign="middle" >13</td></tr><tr><td align="center" valign="middle" >Time</td><td align="center" valign="middle" >7.352247 &#215; 10<sup>−1 </sup></td><td align="center" valign="middle" >9.160095 &#215; 10<sup>−1 </sup></td></tr><tr><td align="center" valign="middle" >Function objective</td><td align="center" valign="middle" >3.000177 &#215; 10<sup>−9 </sup></td><td align="center" valign="middle" >3.000177 &#215; 10<sup>−9</sup></td></tr><tr><td align="center" valign="middle" >Excess dose in the tumor</td><td align="center" valign="middle" >3.809950 &#215; 10<sup>−5 </sup></td><td align="center" valign="middle" >3.809950 &#215; 10<sup>−5</sup></td></tr><tr><td align="center" valign="middle" >Excess dose un critical tissue</td><td align="center" valign="middle" >6.134144 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >6.134144 &#215; 10<sup>−6</sup></td></tr><tr><td align="center" valign="middle" >Excess dose in healthy tissue</td><td align="center" valign="middle" >7.212216 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >7.212216 &#215; 10<sup>−6</sup></td></tr></tbody></table></table-wrap><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> Problem 3718 Pixels</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Method</th><th align="center" valign="middle" >Dual Simplex</th><th align="center" valign="middle" >IPM</th></tr></thead><tr><td align="center" valign="middle" >Iteration</td><td align="center" valign="middle" >24</td><td align="center" valign="middle" >24</td></tr><tr><td align="center" valign="middle" >Time</td><td align="center" valign="middle" >2.754705 s<sup> </sup></td><td align="center" valign="middle" >2.738810 s<sup> </sup></td></tr><tr><td align="center" valign="middle" >Function objective</td><td align="center" valign="middle" >1.258780 &#215; 10<sup>−9 </sup></td><td align="center" valign="middle" >1.258780 &#215; 10<sup>−9</sup></td></tr><tr><td align="center" valign="middle" >Excess dose in the tumor</td><td align="center" valign="middle" >3.318770 &#215; 10<sup>−5 </sup></td><td align="center" valign="middle" >3.318770 &#215; 10<sup>−5</sup></td></tr><tr><td align="center" valign="middle" >Excess dose un critical tissue</td><td align="center" valign="middle" >2.010262 &#215; 10<sup>−6 </sup></td><td align="center" valign="middle" >2.010262 &#215; 10<sup>−6</sup></td></tr><tr><td align="center" valign="middle" >Excess dose in healthy tissue</td><td align="center" valign="middle" >4.522237 &#215; 10<sup>−7 </sup></td><td align="center" valign="middle" >4.522237 &#215; 10<sup>−7</sup></td></tr></tbody></table></table-wrap><p>It is possible to consider the dual simplex method to ensure reliable treatment of medium and small problems, since their computational cost is lower than the interior point methods, but its performance is very similar.</p></sec><sec id="s7"><title>Acknowledgements</title><p>This research was partially sponsored by the Foundation for the Support of Research of the State of S&#227;o Paulo, (FAPESP) and the Brazilian Council for the Development of Science and Technology (CNPq) and Improvement of Higher Education Personnel (CAPES).</p></sec><sec id="s8"><title>Cite this paper</title><p>Salvador, T.R., Carvalho, S.M.S. and Coelho, M.V. (2016) Application of Simplex Method in the Radiotherapy Treatment. Applied Mathematics, 7, 2229-2240. http://dx.doi.org/10.4236/am.2016.717177</p></sec></body><back><ref-list><title>References</title><ref id="scirp.72195-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Péricles Crisostomo de, S. (2008) Programa&amp;atilde;o linear no planejamento do tratamento de cancerporradiocirurgia. Master’s Thesis, Universidade Estadual Paulista (UNESP), S&amp;atilde;o Paulo.</mixed-citation></ref><ref id="scirp.72195-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Rodrigo SartoreloSalemi, V. (2010) Programa&amp;atilde;o Linear aplicada a cria&amp;atilde;o de planejamentosotimizadosemradioterapia. Master’s Thesis, Programa de Pós-Gradua&amp;atilde;oem Biometria, IB, UNESP, S&amp;atilde;o Paulo.</mixed-citation></ref><ref id="scirp.72195-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">David Moreira, F. (2009) Método de pontosinteriores no planejamentoótimo do tratamento de cancerporradioterapia. Master’s Thesis, Universidade Estadual Paulista (UNESP), S&amp;atilde;o Paulo.</mixed-citation></ref><ref id="scirp.72195-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Allen, H. (2003) Designing Radiotherapy Plans with Elastic Constraints and Interior Point Methods. Health Care Management Science, 6, 5-16.  
https://doi.org/10.1023/A:1021970819104</mixed-citation></ref><ref id="scirp.72195-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Cecília Bollini Barboza, C. (2003) Planejamento do tratamentoporradioterapiaatravés de métodos de pontosinteriores. Master’s Thesis, Disserta&amp;atilde;o de Mestrado, ICMC-USP-S&amp;atilde;o Carlos.</mixed-citation></ref><ref id="scirp.72195-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Johns, H.E. and Cunningham, J.R. (1974) Physics of Radiology.</mixed-citation></ref><ref id="scirp.72195-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Barbosa, C. and Oliveira, A.R.L. (2006) Planejamento do tratamentoporradioterapia, através de métodos de pontosinteriores. Pesquisa Operacional.  
https://doi.org/10.1590/S0101-74382006000100001</mixed-citation></ref><ref id="scirp.72195-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Andrea Camila dos Santos, M. (2011) O método de pontosinteriores no planejamento da radioterapia. Universidade Estadual Paulista (UNESP), S&amp;atilde;o Paulo.</mixed-citation></ref><ref id="scirp.72195-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Carvalho, S.M.S. and Oliveira, R. (2014) Predispatch of Hydroelectric Power Systems with Modifications in Network Topologies. Applied Mathematics, 5, 2271-2283.  
https://doi.org/10.4236/am.2014.515221</mixed-citation></ref><ref id="scirp.72195-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Mageras, G.S. and Mohan, R. (1993) Application of Fast Simulated Annealing to Optimization of Conformal Radiation Treatments. Medical Physics, 20, 639-647.  
https://doi.org/10.1118/1.597012</mixed-citation></ref></ref-list></back></article>