<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJCE</journal-id><journal-title-group><journal-title>Open Journal of Civil Engineering</journal-title></journal-title-group><issn pub-type="epub">2164-3164</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojce.2016.64053</article-id><article-id pub-id-type="publisher-id">OJCE-70984</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Experimental Investigation on Sensitivity of Smart Aggregate Embedded in Reinforced Concrete Beam
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Shruti</surname><given-names>R. Gedam</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Suraj</surname><given-names>N. Khante</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Applied Mechanics Department, Government College of Engineering Amravati, Maharashtra, India</addr-line></aff><pub-date pub-type="epub"><day>02</day><month>09</month><year>2016</year></pub-date><volume>06</volume><issue>04</issue><fpage>653</fpage><lpage>669</lpage><history><date date-type="received"><day>June</day>	<month>13,</month>	<year>2016</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>September</month>	<year>26,</year>	</date><date date-type="accepted"><day>September</day>	<month>29,</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Electromechanical impedance (EMI) based lead zirconate titanate (PZT) is an effective sensor to ensure the safety of structure. In civil engineering community, Reinforced Concrete (RC) structure is one of the most familiar engineering structures. Hence, it is very important to monitor the health of structure. In this paper, a new approach of structural health monitoring using embedded PZT in host structure is proposed. There are several issues while embedding PZT inside RC structure which are examined during study. This paper presents two experimental studies on lab sized concrete beams. First implementation was carried out with different methods of embedment of PZT and its sensitivity study when the host structure was subjected to damage. The second implementation was verified in terms of conductance sensitivity of embedded Smart Aggregate (SMAG) in varying orientation 
  <em>i.e.</em> horizontal (0?) and vertical (90?) after embedding in RC beam. The electrical conductance and susceptance signatures of different embedded PZT transducers were measured and damage index was calculated by using Root Mean Square Deviation Method. 
 
</p></abstract><kwd-group><kwd>Concrete</kwd><kwd> Impedance</kwd><kwd> Piezoelectric Materials</kwd><kwd> Sensors</kwd><kwd> Smart Aggregates</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Around the world, health monitoring of concrete structure has been playing an important role in the development of civil engineering. Structural Health Monitoring (SHM) is a process of monitoring the present condition of engineering structures. Many techniques for SHM have been reported in recent years. Moreover, there are several conflicts while monitoring health of concrete structure. This paper presents a new approach of health monitoring of structure based on electromechanical impedance (EMI) technique using embedded PZT sensors.</p><p>Earlier several authors have also proposed the SHM by using PZT smart sensors. Shanker [<xref ref-type="bibr" rid="scirp.70984-ref1">1</xref>] proposed the experimental study on embedded PZT as a sensor by using EMI technique. A simple low cost experimental technique was developed to extract the experimental strain mode shapes of the structure directly by using a surface bonded and embedded PZT sensor. It was found that damage ranging from incipient to near failure (severe) can be located and quantified by using the EMI technique and the experimental mode shapes with desired accuracy. Annamdas et al. [<xref ref-type="bibr" rid="scirp.70984-ref2">2</xref>] proposed a method of embedding PZT sensor in concrete for monitoring concrete. The implementation was verified on various lab sized concrete cubes and the observations were examined by statistical analysis. Wang et al. [<xref ref-type="bibr" rid="scirp.70984-ref3">3</xref>] proposed a health monitoring method based on EMI measurements, which used the electromechanical coupling property of embedded PZT transducers. Khante and Gedam [<xref ref-type="bibr" rid="scirp.70984-ref4">4</xref>] experimentally monitored the health of RC structure by embedding indigenously prepared PZT based smart aggregate in two phases i.e. for healthy and damaged state of RC specimen. Dumoulin et al. [<xref ref-type="bibr" rid="scirp.70984-ref5">5</xref>] studied crack propagation in a reinforced concrete beam by using PZT sensor. Two different types of excitation signals were used (pulse and chirp) and the resulting waves were recorded on the receivers. Based on these signals, different damage indicators were investigated and compared. Kaur et al. [<xref ref-type="bibr" rid="scirp.70984-ref6">6</xref>] investigated the integrity of the low-cost EMI technique and the global vibration technique for health assessment. Fourteen CVS were embedded inside a RC beam, while casting, to obtain the first curvature mode shape of the RC beam. A mode shape curvature based algorithm was adopted for damage detection and severity assessment. Song et al. [<xref ref-type="bibr" rid="scirp.70984-ref7">7</xref>] proposed the smart aggregates as a multifunctional tool for health monitoring. A damage index based on the wavelet packet analysis was used to determine the structural health status. Negi et al. [<xref ref-type="bibr" rid="scirp.70984-ref8">8</xref>] oriented PZT patches in different configuration in host structure. Visalakshi and Bhalla [<xref ref-type="bibr" rid="scirp.70984-ref9">9</xref>] proposed a comparison between the sensing capabilities of surface bonded and embedded piezoceramic (PZT) patches in corrosion assessment for RC structures. Accelerated corrosion tests were performed on RC specimens, and the statistical index and the equivalent parameters were compared for the two types of sensor configurations. B. Xu et al. [<xref ref-type="bibr" rid="scirp.70984-ref10">10</xref>] proposed a PZT based active interface debonding defect detection approach for multi-chamber Steel Reinforced Concrete (SRC) columns and validated experimentally with an irregular multi-chamber SRC specimen. A number of embedded piezo-based functional elements (EPFEs) installed close to the steel plates and piezoelectric ceramic (PZT) patches bonded on the surface of the steel plates were used as actuators and sensors respectively. Based on the amplitude of the measurement of the PZT patches under sinusoidal excitations and the wavelet packet energy under sweep sinusoidal signals, the interface debonding defects was detected successfully. Zhu et al. [<xref ref-type="bibr" rid="scirp.70984-ref11">11</xref>] presented the design and fabrication processes of EMI sensors embedded into concrete structures. Based on the electrical admittance and strain measurements, the health statuses of the continuous rigid frame bridge was monitored and evaluated successfully in the construction and operation stages by using a root-Mean-Square Deviation (RMSD) index. Gupta et al. [<xref ref-type="bibr" rid="scirp.70984-ref12">12</xref>] discussed a newly developed approach for detecting and quantifying corrosion of steel bars utilizing a piezoelectric ceramic (PZT) patch surface bonded on the rebar employing equivalent structural parameters using the Electro-Mechanical Impedance (EMI) technique.</p><p>By using conventional and EMI techniques, a lot of experimental and analytical work has been done by many researchers for health monitoring of structures. Electro-me- chanical impedance technique is considered more reliable and convenient for structural health monitoring. In previous studies, a limited experimental work using embedded PZT was carried out on the structures. Hence, in this paper, an attempt is made to study preparation of indigenous embedded SMAG and the feasibility of EMI technique for in situ SHM. This research article presents EMI approach using a new variant of the embedded SMAG for non-destructive monitoring of concrete structures. The conductance and susceptance signatures acquired over input frequency range are the basis for assessing the health of real-life RC structures.</p></sec><sec id="s2"><title>2. Health Monitoring Based on Electro-Mechanical Impedance (EMI) Technique</title><p>The piezoelectric patch has a unique property to act as both sensor and actuator and can be easily surface bonded or embedded inside host structure. When mechanical stress is applied on PZT patch it produces an electrical charge, which is called as direct piezoelectric effect of PZT. The governing principle of EMI based health monitoring method is to monitor the changes in structure by measuring admittance signature of EMI active sensor bonded onto or embedded into the structure as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> PZT structure interaction [<xref ref-type="bibr" rid="scirp.70984-ref12">12</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x2.png"/></fig><p>Equation (1) below represents the complex electro-mechanical admittance Ȳ of the system.</p><disp-formula id="scirp.70984-formula325"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/11-1880582x3.png"  xlink:type="simple"/></disp-formula><p>where, l, w and h are the length, width and thickness of the PZT patch respectively, j being imaginary number equal to (<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/11-1880582x4.png" xlink:type="simple"/></inline-formula>), ω is angular frequency and kl is the wave number, (e<sub>33</sub>)<sup>T </sup>is the complex electric permittivity at constant stress, Z<sub>a</sub><sub> </sub>is mechanical impedance of the PZT patch, d<sub>31</sub> is the piezoelectric strain coefficient of the PZT material, Ȳ<sup>E </sup>is the complex Young’s modulus under constant electric field, Z is the mechanical impedance of the host structure.</p><p>In EMI based method, high frequencies in the order of few kHz to hundred kHz are used. Mechanical impedance of the host structure is the function of its mass, stiffness, and damping properties. Any changes in admittance signature indicate the presence of structural damage and simultaneously structural properties also changes. The electro- echanical admittance Y consists of the real and the imaginary component called conductance and susceptance respectively. Hence, the magnitude of complex admittance can be calculated as given in Equation (2):</p><disp-formula id="scirp.70984-formula326"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/11-1880582x5.png"  xlink:type="simple"/></disp-formula><p>where, G = Conductance; real part of admittance,</p><p>B = Susceptance; imaginary part of admittance.</p><p>Damage characterization is accomplished by using root mean square deviation method (RMSD). Electrical impedance signatures are compared with each other in which one of the signature known as baseline signature is acquired when the structure is considered to be healthy. The RMSD index compares baseline signature and signature obtained in damaged condition of structure measured over preset frequency range respectively. RMSD of the signature is given by Equation (3),</p><disp-formula id="scirp.70984-formula327"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/11-1880582x6.png"  xlink:type="simple"/></disp-formula><p>where, M = Damage metric (Root Mean Square Deviation),</p><p>G<sub>1</sub> = Conductance before damage,</p><p>G<sub>2</sub> = Conductance after damage.</p></sec><sec id="s3"><title>3. Fabrication of Embedded Smart Aggregate (SMAG)</title><p>Smart Aggregates (SMAGs) are thin PZT transducers casted in small mortar pieces. The PZT transducer is very fragile and can be easily damaged by the vibrator during the casting of concrete structures. The robust PZT patch should be protected in the form of smart aggregate and embedded at the desired position in the concrete structure before casting, eliminating the risk of damaging the transducer during the vibrating process. The method of fabrication was carried out as explained below.</p><p>Step 1: A typical PZT patch of size 10 &#215; 10 &#215; 0.2 mm and 5H grade manufactured by Central Electronics Limited, Sahibabad, Delhi was selected to embed into structure. One of the ends of coaxial head wire was soldered to the electrodes of PZT patch. The soldered wires were then connected to impedance analyzer via connecting fixture for recording admittance signature over the user specified frequency range. Admittance signature of free PZT patches was recorded to ensure proper working.</p><p>Step 2: Encapsulation of waterproofed PZTs i.e. SMAG were formed in two ways as follows:</p><p>SMAG Brick: A hollow rectangular shaped card board mould of 50 &#215; 25 &#215; 25 mm size was prepared and a five sided rich mortar rectangular box with 5 mm side thickness maintaining its top portion open was casted as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref> and allowed to cure for 3 days. The free PZT was then positioned inside one of the side of box using epoxy adhesive to make it waterproof and surface from outside was marked for identification and allowed to (air) cure for 24 hours. Finally, the top layer of box was closed, still maintaining inner portion as hollow. After 24 hours of casting the mould was then allowed to (water) cure for 23 days.</p><p>Metal Wire SMAG Cylinder: Firstly two perpendicular galvanised steel wires of length 100 mm and diameter 1 mm were fixed on top of PZT patch using epoxy adhesive and also remaining portion of PZT patch was coated with epoxy adhesive to make it waterproof and allowed to (air) cure for 24 hours as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>(a). After curing its admittance signatures were obtained. A card board mould of 20 mm diameter was prepared and filled to its half depth with mortar and the waterproofed PZT patch with galvanised steel wire was then placed over it. Then the second half layer over PZT was filled with mortar and mould was allowed to (water) cure for 28 days as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>(b).</p><p>The admittance signatures were again recorded to check any damage incurred during this fabrication process. The robust encapsulated PZT was referred as Smart Aggregate (SMAG) to embed into host structure. If there was any abnormality other than appearances of new modes in signature occurs it would be regarded as failed SMAG. Again the same procedure needs to be performing to fabricate a new SMAG. After completion of these steps the SMAG was ready to embed inside concrete specimen. A typical concrete vibration sensor (CVS) made by Central Electronics Limited, Sahibabad, Delhi shown in <xref ref-type="fig" rid="fig4">Figure 4</xref> was also used to embed in host structure with the fabricated SMAG.</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Smart Aggregate transducers; details of different layers</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x7.png"/></fig><fig-group id="fig3"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> (a) Metal wire SMAG cylinder; details of different layers. (b) Metal wire SMAG cylinder Transducer.</title></caption><fig id ="fig3_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x8.png"/></fig><fig id ="fig3_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x9.png"/></fig></fig-group><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Concrete Vibration Sensor (CVS)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x10.png"/></fig></sec><sec id="s4"><title>4. Experimental Setup for Embedded SMAG Based SHM Investigation</title><p>To perform SHM using EMI technique, the instrument used was digital Impedance Analyzer (LCR meter E4980A) having frequency range of 20 Hz to 2 MHz and its connecting fixture, along with a USB cable and VEE Pro 9.32 for data acquisition system as</p><p>shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. The tests were performed for the healthy state of host structure and then for damaged state of structure. 100 mm &#215; 100 mm &#215; 410 mm reinforced concrete beams with M20 grade concrete and Fe 415 steel were monitored. The reinforcement provided was 2 &#215; 8 mm ϕ Fe 415 steel bars at top and at bottom along with stirrups of Fe 250, 6 mm ϕ @ 80 mm c/c. The Maximum Size of Aggregate (MSA) was limited to 20 mm. Test specimen was cured for 7 days. Two different experimental studies were performed on two RC beams in which first study was the comparative study of RC beam with CVS and indigenously prepared SMAG brick and metal wire SMAG cylinder and the second study was conductance sensitivity investigations on SMAG embedded in varying orientation and surface bonded PZT.</p><sec id="s4_1"><title>4.1. Comparative Study of RC Beam with CVS and Indigenously Prepared SMAG Brick and Metal Wire SMAG Cylinder</title><p>A simply supported RC beam was casted with embedded metal wire SMAG cylinder and CVS located at 100 mm distance from left end of beam and 30 mm distance from top of beam. SMAG brick was embedded at 100 mm distance from right end of beam and 30 mm distance from the top of beam. The locations of SMAGs are as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>.</p><p>The conductance (G) and susceptance (B) of SMAG and CVS were directly measured through impedance analyzer for the frequency range of 100 kHz to 400 kHz. From the obtained data, the graph of conductance versus frequency and susceptance versus frequency were plotted. These graphs were said to be the conductance signature and susceptance signature or just a signature shown by particular sensor for specimen. This data was saved in excel format and can be available as and when required. The damage was introduced by loading the specimen under Universal Testing Machine (UTM) in the form of significant visible crack as shown in <xref ref-type="fig" rid="fig7">Figure 7</xref> and the conductance and susceptance signatures were obtained for damaged specimen. The conductance and susceptance for healthy state and damaged state were compared.</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Experimental setup of EMI technique</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x11.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> RC beam with embedded SMAG brick, metal wire SMAG cylinder and CVS</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x12.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Damaged RC beam</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x13.png"/></fig></sec><sec id="s4_2"><title>4.2. Conductance Sensitivity Investigations on SMAG Embedded in Varying Orientation and Surface Bonded PZT Headings</title><p>For this beam, embedded SMAG brick was used same as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. Two SMAG bricks were embedded in RC beam below 30mm from top of beam, first was at 160 mm from right end of beam and positioned at 0&#186; with horizontal i.e. d31 mode. In d31 mode, response is measured across the poling direction (dir-3) and strain is applied along longitudinal direction (dir-1). Second SMAG was embedded at 170 mm from right end of beam and positioned at 90&#186; with horizontal i.e. d33 mode. In d33 mode, both response and application of strain are measured across the poling direction. <xref ref-type="fig" rid="fig8">Figure 8</xref> shows plan of SMAG Brick and <xref ref-type="fig" rid="fig9">Figure 9</xref> shows elevation of SMAG Brick. The typical block diagram of RC beam with embedded 0˚ SMAG brick and 90&#186; SMAG brick is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>0. Also PZT patch was surface bonded at 160 mm from right end of beam as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>1. Damage in RC beam was introduced by using UTM as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>2.</p><p>The data for healthy state and different damaged states were compared for all the specimens in the frequency range of 100 kHz to 400 kHz. The program of VEE PRO 9.32 directly gives the plot of Conductance versus Frequency and Susceptance versus Frequency.</p><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Plan of SMAG bric</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x14.png"/></fig><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Elevation of SMAG brick</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x15.png"/></fig><fig id="fig10"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Typical block diagram of RC beam with embedded 0˚ SMAG brick and 90˚ SMAG brick</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x16.png"/></fig><fig id="fig11"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>1</label><caption><title> RC beam with embedded SMAG in d<sub>31</sub> and d<sub>33</sub> mode and surface bonded PZT</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x17.png"/></fig><fig id="fig12"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>2</label><caption><title> Damaged RC beam with embedded SMAG in d<sub>31</sub> and d<sub>33</sub> mode and surface bonded PZT</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x18.png"/></fig></sec></sec><sec id="s5"><title>5. Results and Discussion</title><p>The Conductance, susceptance and RMSD index were plotted for all the embedded SMAG, for healthy and damaged condition. VEE Pro 9.32 software was used for data acquisition and data processing.</p><sec id="s5_1"><title>5.1. Healthy and Damaged Condition Response of RC Beam with CVS and Indigenously Prepared SMAG Brick and Metal Wire SMAG Cylinder</title><sec id="s5_1_1"><title>5.1.1. Response for Healthy and Damaged Condition of Embedded SMAG and CVS</title><p>The healthy and damaged response of structure was obtained, with the SMAG brick, metal wire SMAG cylinder and CVS embedded in simply supported RC beam. In the frequency range of 100 to 400 kHz, corresponding conductance and susceptance values were recorded by impedance analyzer. <xref ref-type="fig" rid="fig1">Figure 1</xref>3 and <xref ref-type="fig" rid="fig1">Figure 1</xref>4 show conductance and susceptance signature for healthy and damaged beam by embedded SMAG brick. <xref ref-type="fig" rid="fig1">Figure 1</xref>5 and <xref ref-type="fig" rid="fig1">Figure 1</xref>6 show conductance and susceptance signature for healthy and damaged beam by embedded metal wire SMAG cylinder. <xref ref-type="fig" rid="fig1">Figure 1</xref>7 and <xref ref-type="fig" rid="fig1">Figure 1</xref>8 show conductance and susceptance signature for healthy and damaged beam by embedded CVS.</p><p>It was found that SMAG brick gives precise results than metal wire SMAG cylinder, may be due to presence of SMAG brick near to damage than metal wire SMAG cylinder and CVS. In this case, SMAG brick was 80 mm away from the crack while metal wire SMAG cylinder and CVS being 120 mm away from the crack.</p><p>It was observed from the conductance and susceptance signatures that the embedded SMAG shows damage sensitivity with the lateral and vertical shifting of the peaks in damaged and healthy signatures. It was also found from conductance signatures as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>3, <xref ref-type="fig" rid="fig1">Figure 1</xref>5 and <xref ref-type="fig" rid="fig1">Figure 1</xref>7 that, first peak occurs in frequency range of 100 - 200 kHz for SMAG brick and metal wire SMAG cylinder whereas; CVS gives first peak in between 200 - 300 kHz frequency.</p><fig id="fig13"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>3</label><caption><title> Conductance signature for healthy and damaged beam by embedded SMAG brick</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x19.png"/></fig><fig id="fig14"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>4</label><caption><title> Susceptance signature for healthy and damaged beam by embedded SMAG brick</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x20.png"/></fig><fig id="fig15"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>5</label><caption><title> Conductance signature for healthy and damaged beam by embedded metal wire SMAG cylinder</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x21.png"/></fig><fig id="fig16"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>6</label><caption><title> Susceptance signature for healthy and damaged beam by embedded metal wire SMAG cylinder</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x22.png"/></fig><fig id="fig17"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>7</label><caption><title> Conductance signature for healthy and damaged beam by embedded CVS</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x23.png"/></fig><fig id="fig18"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>8</label><caption><title> Susceptance signature for healthy and damaged beam by embedded CVS</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x24.png"/></fig></sec><sec id="s5_1_2"><title>5.1.2. RMSD Index</title><p>The severity of damage was obtained by using root mean square deviation technique (RMSD) as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>9. The damage index recorded by SMAG brick was 10.02%, by using metal wire SMAG cylinder was 7.23% and with CVS was found to be 7.51% between frequency ranges of 100 - 400 kHz. It is well established that both SMAG brick and metal wire SMAG cylinder are as effective as CVS in detecting incipient level damages.</p></sec></sec><sec id="s5_2"><title>5.2. Response of Embedded SMAG in Varying Orientation and Surface Bonded PZT</title><sec id="s5_2_1"><title>5.2.1. Response for Healthy and Damaged Condition of Embedded SMAG and Surface Bonded PZT</title><p>This section compares the conductance and susceptance response of the two embedded SMAG oriented in two typical configurations i.e. horizontal and vertical and one surface bonded PZT patch. All the signatures were plotted and compared for each stage.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref>0 and <xref ref-type="fig" rid="fig2">Figure 2</xref>1 show conductance and susceptance signature for healthy and damaged beam by (0˚) SMAG. <xref ref-type="fig" rid="fig2">Figure 2</xref>2 and <xref ref-type="fig" rid="fig2">Figure 2</xref>3 show conductance and susceptance signature for healthy and damaged beam by (90˚) SMAG. The conduc-</p><fig id="fig19"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>9</label><caption><title> RMSD index for beam</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x25.png"/></fig><fig id="fig20"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>0</label><caption><title> Conductance signature for healthy and damaged beam by (0˚) SMAG</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x26.png"/></fig><fig id="fig21"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>1</label><caption><title> Susceptance signature for healthy and damaged beam by (0˚) SMAG</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x27.png"/></fig><fig id="fig22"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>2</label><caption><title> Conductance signature for healthy and damaged beam by (90˚) SMAG</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x28.png"/></fig><fig id="fig23"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>3</label><caption><title> Susceptance signature for healthy and damaged beam by (90˚) SMAG</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x29.png"/></fig><p>tance and susceptance signature by surface bonded PZT are shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>4 and <xref ref-type="fig" rid="fig2">Figure 2</xref>5 respectively.</p></sec><sec id="s5_2_2"><title>5.2.2. RMSD Index</title><p>The damage index is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>6. Since crack occurred nearer to the horizontal (0˚) configuration SMAG, the RMSD recorded was 8.01% and that by the vertical (90˚) configuration SMAG was 6.47%. The RMSD recorded by surface bonded PZT was found to be highest as 50.50% since crack occurred exactly at the surface bonded PZT as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>7, due to which surface bonded PZT was excessively effective in detecting crack.</p><fig id="fig24"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>4</label><caption><title> Conductance signature for healthy and damaged beam by surface bonded PZT</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x30.png"/></fig><fig id="fig25"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>5</label><caption><title> Susceptance signature for healthy and damaged beam by surface bonded PZT</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x31.png"/></fig><fig id="fig26"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>6</label><caption><title> RMSD index for beam</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x32.png"/></fig><fig id="fig27"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>7</label><caption><title> Crack occurred exactly at the surface bonded PZT</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/11-1880582x33.png"/></fig></sec></sec></sec><sec id="s6"><title>6. Conclusions</title><p>This experimental work has presented a method to monitor the damages in concrete structure using embedded SMAG. It was verified from the results that the incipient level damage could be easily identified by lateral and vertical shifting of peaks. Since the same SMAG act as actuator and sensor, this saves the number of transducers and the associated wiring. Being high frequency technique, signatures have no interference with noise. It is well established from the first experiment that damage sensitivity of embedded SMAG depends on its location from damage and varies, i.e. nearer the location of embedded SMAG from damage, more is the sensitivity. By comparing the conductance and susceptance signatures obtained from indigenously prepared SMAG with the standard CVS, it was well established that the SMAG was also equally effective in detecting damage as damage detected by CVS for the same structure.</p><p>The second investigational study presented the comparison of SMAG embedded in two different orientation i.e. horizontal (0˚) and vertical (90˚) for their sensitivity towards conductance of RC beam and it was found that conductance peak was the highest in vertical (90˚) SMAG within less frequency range. Hence, it can be advised to ensure the orthogonal positions of SMAG while using in embedded positions in real life struc- tures. Health monitoring of structure using embedded SMAG is a better alternative for conventional tedious and time consuming SHM techniques with economy.</p></sec><sec id="s7"><title>Cite this paper</title><p>Gedam, S.R. and Khante, S.N. (2016) Experimental Investigation on Sensitivity of Smart Aggregate Embedded in Reinforced Concrete Beam. Open Journal of Civil Engineering, 6, 653-669. http://dx.doi.org/10.4236/ojce.2016.64053</p></sec></body><back><ref-list><title>References</title><ref id="scirp.70984-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Shanker, R. (2009) An Integrated Approach for Structural Health Monitoring. Indian Institute of Technology, Delhi.</mixed-citation></ref><ref id="scirp.70984-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Annamdas, V., Yang, Y. and Soh, C. (2010) Impedance Based Concrete Monitoring Using Embedded PZT Sensors. International Journal of Civil and Structural Engineering, 1, 414-424.</mixed-citation></ref><ref id="scirp.70984-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Wang, D.S., Li, Z., Zhang, S.S. and Zhu, H.P. (2013) Experimental Study on Sensitivity of Embedded PZT Impedance Transducers to Crack Damage of Reinforced Concrete Beam. The 13th International Symposium on Structural Engineering.</mixed-citation></ref><ref id="scirp.70984-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Khante, S.N. and Gedam, S.R. (2016) PZT Based Smart Aggregate for Unified Health Monitoring of RC Structures. Open Journal of Civil Engineering, 6, 42-49.</mixed-citation></ref><ref id="scirp.70984-ref5"><label>5</label><mixed-citation publication-type="book" xlink:type="simple">Dumoulin, C., Karaiskos, G. and Deraemaeker, A. (2015) Monitoring of Crack Propagation in Reinforced Concrete Beams Using Embedded Piezoelectric Transducers. In: Ohtsu, M., Ed., Acoustic Emission and Related Non-Destructive Evaluation Techniques in the Fracture Mechanics of Concrete, Woodhead Publishing, Cambridge, 161-175.  
http://dx.doi.org/10.1016/B978-1-78242-327-0.00008-8</mixed-citation></ref><ref id="scirp.70984-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Kaur, N., Gupta, N., Jain, N. and Bhalla, S. (2013) Integrated Global Vibration and Low-Cost EMI Technique for Structural Health Monitoring of RC Structures Using Embedded PZT Patches. Proceedings of UKIERI Congress on Innovations in Concrete Construction, B. R. Ambdekar National Institute of Technology, Jalandhar, 5-8 March 2013, Paper No. UCC-488.</mixed-citation></ref><ref id="scirp.70984-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Song, G.B., Gu, H.C. and Mo, Y.-L. (2008) Smart Aggregates: Multi-Functional Sensors for Concrete Structures—A Tutorial and a Review. Smart Materials and Structures, 17, Article ID: 033001. http://dx.doi.org/10.1088/0964-1726/17/3/033001</mixed-citation></ref><ref id="scirp.70984-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Negi, P., Kaur, N., Bhalla, S. and Chakraborty, T. (2014) Experimental Strain Sensitivity Investigations on Embedded PZT Patches in Varying Orientations. Proceedings of 9th Biennial Conference on Structural Engineering Convention (SEC 2014), New Delhi, 22-24 December 2014, 2615-2620.</mixed-citation></ref><ref id="scirp.70984-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Visalakshi, T. and Bhalla, S. (2014) Reinforcement Corrosion Assessment Capability of Surface Bonded and Embedded Piezo Sensors for RC Structures. Journal of Intelligent Material Systems and Structures, 26, 2304-2313.</mixed-citation></ref><ref id="scirp.70984-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Xu, B., Li, Z. and Dyke, S.J. (2015) Interface Debonding Detection for an Irregular Complex Multi-Chamber Steel Reinforced Concrete Column with PZT Measurements. 11th International Workshop on Advanced Smart Materials and Smart Structures, Technology University of Illinois, Urbana-Champaign, 1-2 August 2015..</mixed-citation></ref><ref id="scirp.70984-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Wang, D.S., Zhang, J.B. and Zhu, H.P. (2015) Embedded Electromechanical Impedance and Strain Sensors for Health Monitoring of a Concrete Bridge. Journal of Shock and Vibration, 2015, Article ID: 821395. http://dx.doi.org/10.1155/2015/821395</mixed-citation></ref><ref id="scirp.70984-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Talakokula, V., Bhalla, S., Bhattacharjee, B. and Gupta, A. (2015) Non-Destructive Assessment of Rebar Corrosion Based on Equivalent Structural Parameters Using Peizo-Transducers. Current Science, 108, 1890-1900.</mixed-citation></ref></ref-list></back></article>