<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JBBS</journal-id><journal-title-group><journal-title>Journal of Behavioral and Brain Science</journal-title></journal-title-group><issn pub-type="epub">2160-5866</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jbbs.2016.610037</article-id><article-id pub-id-type="publisher-id">JBBS-70026</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Development of a Stimulation System for the Gustatory Eye-Blink Response in Humans
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ichiro</surname><given-names>Ashida</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yozo</surname><given-names>Miyaoka</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Health and Nutrition, Niigata University of Health and Welfare, Niigata, Japan</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>miyaoka@nuhw.ac.jp(YM)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>24</day><month>08</month><year>2016</year></pub-date><volume>06</volume><issue>10</issue><fpage>387</fpage><lpage>392</lpage><history><date date-type="received"><day>July</day>	<month>22,</month>	<year>2016</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>August</month>	<year>21,</year>	</date><date date-type="accepted"><day>August</day>	<month>24,</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  An inexpensive stimulation system for recording eye-blink responses elicited by taste stimuli has been developed using a manually controlled syringe and tasimetric sensor. The system requires neither an intra-oral device nor clamping of the head and tongue for natural eye-blink responses. The data recorded by the system have a high temporal resolution that is likely to be sufficient for the analysis of eye-blink responses based on video recordings.
 
</p></abstract><kwd-group><kwd>Eye-Blink</kwd><kwd> Taste Liquid</kwd><kwd> Stimulation Device</kwd><kwd> Tasimetric Sensor</kwd><kwd> Human</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Taste stimuli applied to the tongue can elicit facial responses in humans [<xref ref-type="bibr" rid="scirp.70026-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.70026-ref2">2</xref>] . The authors have previously reported that solutions of the four basic tastes and several commercial confections can also elicit eye-blink responses [<xref ref-type="bibr" rid="scirp.70026-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.70026-ref4">4</xref>] . Among the eye-blink parameters, the latency of the eye-blinks is particularly important for providing an estimate of the conduction path and the central processing of eye-blinks. In these experiments, the analysis of eye-blink parameters was based on video movies taken using commercially available cameras, with temporal resolutions ranging from 17 to 67 ms.</p><p>For calculating latency, the stimulation time and the time when the eye-blink started must be recorded synchronously. A number of recording systems that can accurately identify these two time points have been developed for humans and animals over the last half-century. For humans, drinkometers have been developed and used to measure gustatory reaction time [<xref ref-type="bibr" rid="scirp.70026-ref5">5</xref>] - [<xref ref-type="bibr" rid="scirp.70026-ref8">8</xref>] . Some drinkometers use a system in which a signal pulse is generated at the moment when a stimulation liquid is poured from the orifice of a liquid delivery pipette and an electrical circuit between the body and pipette is closed. However, such a system is likely to be unsuitable for eye-blink experiments because the system requires the use of clamps on the head and tongue of the participants, which would affect the natural eye-blink responses. Other drinkometers use an intra-oral device to improve the temporal resolution [<xref ref-type="bibr" rid="scirp.70026-ref6">6</xref>] , but these devices seem to be expensive, and it can be difficult to adjust and insert the intra-oral device for a large number of participants.</p><p>This study aimed to develop an inexpensive stimulation system, without the use of an intra-oral device or the hard clamping method, to record the natural eye-blink responses elicited by taste stimuli.</p></sec><sec id="s2"><title>2. Materials and Methods</title><sec id="s2_1"><title>2.1. Stimulation</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref> shows the stimulation-recording system developed. A silicon tube (i.d.: 3.2 mm) was connected to a needleless plastic syringe (20 ml) to provide the stimulation liquid (“a” in <xref ref-type="fig" rid="fig1">Figure 1</xref>) through a three-way stopcock (“b”). One of the branches led to the stimulation site, and the other branch was connected to a water-resistant tasimetric sensor (“c”). Changes in the hydraulic pressure detected by the sensor were recorded and stored on a Power Lab&#174; system.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The developed stimulation-recording system. “a”, A plustic syringe; “b”, a three-way stopcock; “c”, a water-resistant tasimetric sensor; “d”, a sensor for detecting liquid drops; “e”, A microcomputer for generating rectangular pulses. “a-d” are connected with silicon tubes</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-3900500x2.png"/></fig></sec><sec id="s2_2"><title>2.2. Recording</title><p>The injection of the stimulation liquid from the end of the silicon tube (“d” in <xref ref-type="fig" rid="fig1">Figure 1</xref>) was recorded using a sensor for detecting liquid drops to evaluate the temporal accuracy of the system. The sensor was joined to a microcomputer (“e”), and a computer program for generating rectangular pulses was developed using the Arduino&#174; script. The pulses, synchronized with the liquid injections, were recorded and stored on the PowerLab&#174; system.</p></sec><sec id="s2_3"><title>2.3. Procedures</title><p>The inside of the stimulation device (including a syringe, tasimetric sensor, and three silicon tubes) was enclosed and filled with stimulation liquid, except at the stimulation site. Thus, the two signals (i.e., the hydraulic pressure and liquid injection pulse) were expected to be transmitted to the recorder almost simultaneously. Fifty recordings were conducted using the developed system with water as the stimulus to verify the transmission. Ten recordings of “very low pressure” (&lt;1.0 kPa) were not used for the analysis because these signals were too small and flat to distinguish from the baseline. To confirm the effects of the intensity of the syringe push, the delays between the starting point of the hydraulic pressure change and liquid injection were recorded. Further, the recorded delays were classified into two groups based on the intensity of the hydraulic pressure (the threshold for the two groups was set at 2.5 kPa, which was determined from the results of our preliminary experiments). The Student’s t-test was used to examine the significance of the differences, with a P &lt; 0.05 considered significant.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><p>Some gustatory stimulation systems in previous reports [<xref ref-type="bibr" rid="scirp.70026-ref7">7</xref>] - [<xref ref-type="bibr" rid="scirp.70026-ref9">9</xref>] required hard clamps on the head and tongue to establish strict positioning for electrical circuits, but these clamps may disturb the participant’s natural eye-blinks. The tongue of the participant was located at “d” in <xref ref-type="fig" rid="fig1">Figure 1</xref> in the actual (human) experiments. The stimulation site of the silicon tube was held in the participant’s mouth without any clamping devices in the developed system because the record of the hydraulic pressure was used as a synchronized signal for the injection of the stimulation liquid.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows sample data recorded by the new system. The delay between the start of the hydraulic pressure change (“a” in <xref ref-type="fig" rid="fig2">Figure 2</xref>) and the liquid injection (“b”) was 132.6 ms in this record. <xref ref-type="fig" rid="fig3">Figure 3</xref> summarizes the results of the 40 trials that were conducted. The average delays for the lower and higher pressures were 133.2 &#177; 7.1 ms (n = 17) and 134.5 &#177; 7.1 ms (n = 23), respectively. No significant difference between the two average delays was observed (P = 0.56). The standard deviations (SDs) of the delays, 7.1 ms for both, were probably caused by the following two situations. First, the manual pushing of the syringe resulted in inconsistent speed and power of the pushing among trials. Mechanically controlled pushing by console devices (e.g., electromagnetic valves) will further reduce SDs of the delays, although the devices will a larger cost for the system. The fact about the homogeneity between the two average delays (<xref ref-type="fig" rid="fig3">Figure 3</xref>) suggests</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Sample data recorded by the developed system. Upper trace shows the changes in the hydraulic pressure detected by the tasimetric sensor (“c” in <xref ref-type="fig" rid="fig1">Figure 1</xref>). Lower trace shows the liquid detection by the drop sensor (“d” in <xref ref-type="fig" rid="fig1">Figure 1</xref>). “a”, the start of the hydraulic pressure change; “b”, the the liquid injection. A delay between the hydraulic pressure and liquid injection (“b”-“a”) was 132.6 ms in the sample data</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-3900500x3.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Delay between the hydraulic pressure and the liquid injection in low and higher pressures. Each circle and thick bar indicate each record and the average. The two averages are statistically homogeneous (Student’s t-test, P = 0.56)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-3900500x4.png"/></fig><p>that manual pushing is enough to accurately identify the stimulation time, whether the experimenters are not special trained for the pushing. Second, the pressure drop in the silicon tubes was likely to be involved in the delays [<xref ref-type="bibr" rid="scirp.70026-ref10">10</xref>] .</p><p>The accuracy of the transmission (i.e., a SD of 7.1 ms) is sufficient to allow the analysis of the eye-blink response based on video recordings because the sampling intervals in commercial video cameras (17 ms at minimum) are much longer than the SD value. However, when surface electromyograms (EMGs) of, for example, the orbicular is oculi muscle, are used as biological signals, the accuracy of the recorded stimulation time should be carefully considered because the sampling intervals of the EMGs usually range from 0.1 to 1.0 ms.</p></sec><sec id="s4"><title>4. Conclusion</title><p>A simple and inexpensive stimulation system for eye-blink responses elicited by taste stimuli was developed using a tasimetric sensor. The system requires neither an intra-oral device nor clamping of the head and tongue. The data recorded by the system have high temporal resolution (approximately 7 ms) that is likely to be sufficient for the analysis of eye-blink responses based on video recordings.</p></sec><sec id="s5"><title>Acknowledgements</title><p>This study was supported in part by a Grant-in-Aid for Scientific Research from the Ministry of Education, Science and Culture of Japan (No. 24501001).</p></sec><sec id="s6"><title>Conflict of Interest</title><p>The authors declare no conflict of interest associated with this manuscript.</p></sec><sec id="s7"><title>Cite this paper</title><p>Ashida, I. and Mi- yaoka, Y. (2016) Development of a Stimulation System for the Gustatory Eye-Blink Re- sponse in Humans. Journal of Behavioral and Brain Science, 6, 387-392. http://dx.doi.org/10.4236/jbbs.2016.610037 </p></sec></body><back><ref-list><title>References</title><ref id="scirp.70026-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Norgren, R. (1976) Taste Pathways to Hypothalamus and Amygdala. Journal of Comparative Neurology, 166, 17-30. http://dx.doi.org/10.1002/cne.901660103</mixed-citation></ref><ref id="scirp.70026-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Steiner, J.E. (1979) Human Facial Expressions in Response to Taste and Smell Stimulation. Advances in Child Development and Behavior, 13, 257-295. http://dx.doi.org/10.1016/S0065-2407(08)60349-3</mixed-citation></ref><ref id="scirp.70026-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Ashida, I., Tamaki, Y. and Miyaoka, Y. (2013) Eye Blink Responses to the Four Basic Taste Stimuli in Healthy Young Humans. Journal of Behavioral and Brain Science, 3, 379-384. http://dx.doi.org/10.4236/jbbs.2013.34038</mixed-citation></ref><ref id="scirp.70026-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Ashida, I., Tamaki, Y. and Miyaoka, Y. (2013) Eye Blink Responses Elicited by Taste Stimuli Provided with Commercial Confectioneries. The Japanese Association for the Study of Taste and Smell, 20, 241-242.</mixed-citation></ref><ref id="scirp.70026-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Matsuo, T. and Fukuda, K. (1996) A Development of Automatic Analyzing System of Eyeblinks Recorded in the Video Image. Japanese Journal of Physiological Psychology and Psychohysiology, 14, 17-21. http://dx.doi.org/10.5674/jjppp1983.14.17</mixed-citation></ref><ref id="scirp.70026-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Goto, T.K., Yeung, A.W., Suen, J.L., Fong, B.S. and Ninomiya, Y. (2015) High Resolution Time-Intensity Recording with Synchronized Solution Delivery System for the Human Dynamic Taste Perception. Journal of Neuroscience Methods, 245, 147-155. http://dx.doi.org/10.1016/j.jneumeth.2015.02.023</mixed-citation></ref><ref id="scirp.70026-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Lester, B. and Halpern, B.P. (1979) Effect of Stimulus Presentation Duration on Gustatory Reaction Time. Physiology &amp; Behavior, 22, 319-324. http://dx.doi.org/10.1016/0031-9384(79)90093-3</mixed-citation></ref><ref id="scirp.70026-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Yamamoto, T. and Kawamura, Y. (1981) Gustatory Reaction Time in Human Adults. Physiology &amp; Behavior, 26, 715-719. http://dx.doi.org/10.1016/0031-9384(81)90149-9</mixed-citation></ref><ref id="scirp.70026-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Halpern, B.P. (1986) Constraints Imposed on Taste Physiology by Human Taste Reaction Time Data. Neuroscience &amp; Biobehavioral Reviews, 10, 135-151. http://dx.doi.org/10.1016/0149-7634(86)90024-2</mixed-citation></ref><ref id="scirp.70026-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Rathakrishnan, E. (2012) Fluid Mechanics: An Introduction. 3rd Edition, PHI Learning Private Limited, New Delhi.</mixed-citation></ref></ref-list></back></article>