<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JBCPR</journal-id><journal-title-group><journal-title>Journal of Building Construction and Planning Research</journal-title></journal-title-group><issn pub-type="epub">2328-4889</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jbcpr.2016.43009</article-id><article-id pub-id-type="publisher-id">JBCPR-69696</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Research on Passive Design Optimization about an Experimental Rural Residence in Hot Summer and Cold Winter Region of China
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Qian</surname><given-names>Wu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Weijun</surname><given-names>Gao</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Faculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, Japan</addr-line></aff><aff id="aff1"><addr-line>School of Civil Engineering and Architecture, Zhejiang University of Science and Technology, Hangzhou, China</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>wuqian1003@163.com(QW)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>12</day><month>08</month><year>2016</year></pub-date><volume>04</volume><issue>03</issue><fpage>131</fpage><lpage>156</lpage><history><date date-type="received"><day>April</day>	<month>15,</month>	<year>2016</year></date><date date-type="rev-recd"><day>Accepted:</day>	<month>August</month>	<year>7,</year>	</date><date date-type="accepted"><day>August</day>	<month>12,</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In China, rural residential environment under the poor construction measures has not been satisfactory due to the backward infrastructure of countryside and the lacking of professional planning, which will result in considerable amount of energy consumption in the future. The economy of rural residences in the hot summer and cold winter region of China is relative developed, but the indoor thermal environmental quality is not so good. In this paper, the design strategies directed by passive design ideas for a small experimental rural residential building located in Hangzhou city was introduced and researched in response to hot summer and cold winter climate. Through modeling solution undertaken by Ecotect software, the building performance was simulated and analyzed for the optimization of design factors, such as shape, roof angle, insulation system, shading devices, as well as day-lighting system. Based on the above study, a set of appropriate energy-saving technologies were provided for improving the new rural residences construction in Hangzhou, which should also be recommended to other projects constructed in the same climate region.
 
</p></abstract><kwd-group><kwd>Hot Summer and Cold Winter Region</kwd><kwd> Rural Residence</kwd><kwd> Passive Design</kwd><kwd> Simulation</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Since October of 2005, one important historical task was determined by Chinese government to develop the socialist new countryside consisting of constructing advanced rural residences and improving people’s living conditions. Based on the report [<xref ref-type="bibr" rid="scirp.69696-ref1">1</xref>] , the area of rural residences in 2010 reached 23 billion m<sup>2</sup>, about 50% of national total area in this year; by 2020, it is estimated that the rural building area will reach 42.5 billion m<sup>2</sup>, responsible for 62% [<xref ref-type="bibr" rid="scirp.69696-ref2">2</xref>] of the total gross floor area in China. Due to the backward infrastructure of countryside and the lacking of professional planning, rural residential environment under the poor construction measures has not been satisfactory for ignoring the environmental factors, such as climate, building directions, natural ventilation and so on, which will lead to considerable amount of energy consumption in the future [<xref ref-type="bibr" rid="scirp.69696-ref3">3</xref>] .</p><p>China’s territory ranges from 18˚N to 53˚N and covers five different climatic regions (see <xref ref-type="fig" rid="fig1">Figure 1</xref>) across the mainland: severe cold region, cold region, moderate region, hot summer/cold winter region, and hot summer/warm winter region, among of which the hot summer/cold winter region contains 40% of population, 20% of national territorial area, and 48% of the gross national product. The climate condition in hot summer/cold winter region is relevant severe: the monthly mean temperature ranges from 15˚C to 30˚C and peaks at 40˚C in July. During the summer months of May through September, the relative humidity is remarkably high, from 70% to 80%. While the winter months of November to February show an average temperature of 4˚C and the minimum of −10˚C in January.</p><p>Hangzhou belongs to the hot summer/cold winter region, characterized by 118.35˚ ~ 120.5˚ East longitude and 29.18˚ ~ 30.55˚ North latitude. As the capital of Zhejiang province, Hangzhou city has a relatively developed economy in rural area. According to 2008 figures reported by the Hangzhou city bureau of statistics (NBS), the rural per capita net income had broken through 10,000 RMB [<xref ref-type="bibr" rid="scirp.69696-ref4">4</xref>] (see <xref ref-type="fig" rid="fig2">Figure 2</xref>). Since reform and opening up in the eighties of China, the number of new rural residences has increased sharply. In 2010, researchers carried out the investigation on the construction, materials, indoor thermal environment of rural residences in the 11 districts including 20 villages of</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The map of five climate regions of China</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x4.png"/></fig><p>Zhejiang [<xref ref-type="bibr" rid="scirp.69696-ref5">5</xref>] . The results of research indicated that from 1980-2000, the amount of rural residential buildings accounted for 32% of the total construction. Due to the reason that heat insulation and natural ventilation for buildings had not been considered, the 50% of villagers used to buy air conditioners to improve the comfort level of indoor thermal environment which led to the increasing of energy consumption [<xref ref-type="bibr" rid="scirp.69696-ref5">5</xref>] . Reference [<xref ref-type="bibr" rid="scirp.69696-ref6">6</xref>] introduced a field survey carried out in three typical villages including 150 households around Hangzhou to investigate the human environment and energy consumption. In this survey, several findings were provided: a) the ownership of solar water heaters accounted for 70% in all the households, but lacking other renewable energy utilization; b) more than 50% of households had air conditioners, consuming 50% of residential energy; c) less than 50% of households showed the satisfactory to the indoor thermal environment and the evaluation to the summer was more poor than the winter; d) large window areas was popular for ventilation and good sight, but conducted the problems of over hot in summer and cold in winter. Thus, the air conditioner has been the necessity in rural residents’ life. <xref ref-type="fig" rid="fig3">Figure 3</xref> shows the ownership of air conditioners per 100 households, where can be seen that the number has broken through 100 in 2010 and increased year by year.</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Annual income per rural resident from 2000~2013</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x5.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> The ownership of air conditioners per 100 households in Hangzhou rural area</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x6.png"/></fig><p>In this paper, the design strategies of a small experimental residence directed by passive design ideas was introduced and researched in response to Hangzhou climate. Through modeling solution undertaken by Ecotect software, the building performance was simulated and analyzed for the optimum combination of design factors. Based on the above study, a set of appropriate energy-saving technologies were provided for improving the new rural residences construction in Hangzhou, which should also be recommended to other projects constructed in the same climate region.</p></sec><sec id="s2"><title>2. Critical Review of Previous Studies</title><p>The design idea of passive energy building was firstly suggested by American Architect Bernard Baruch, the purpose of which was to achieve highest thermal comfort conditions on low total costs through making full use of renewable energy resources to reduce fossil energy consumption, and to achieve highest thermal comfort conditions on low total costs.</p><p>Nowadays, passive cooling and heating techniques have been increasingly encouraged by international regulations. According to the reference [<xref ref-type="bibr" rid="scirp.69696-ref7">7</xref>] , passive cooling relies on the use of techniques that enable controlling and dissipating the solar radiation and thermal gains during summer. Contrarily, heat passive features take advantage of sunlight and its heating effect thanks to their high capacity of absorbing solar radiation, storing and releasing heat inside the building.</p><sec id="s2_1"><title>2.1. Theoretical Exploration</title><p>Reference [<xref ref-type="bibr" rid="scirp.69696-ref8">8</xref>] introduced the difference of energy-saving techniques between China and Europe, and carried out the feasibility on the implementation of passive design in the severe cold region, cold region and hot summer/cold winter region of China. The results indicated that improving the design and construction level of energy-saving buildings in China could be realized through demonstration projects practiced in the above regions due to the huge energy efficiency potential. In this study [<xref ref-type="bibr" rid="scirp.69696-ref9">9</xref>] , the climatic parameters should be considered for the designing of energy-saving residential buildings in the hot summer/cold winter region. Several factors such as shape coefficient control and window-wall ratio were concluded as the crucial strategies for energy efficiency. Reference [<xref ref-type="bibr" rid="scirp.69696-ref10">10</xref>] demonstrated the concept, heat gaining and design proposal about the solar energy residences, summarized the methods of solar energy utilization on planning and design.</p></sec><sec id="s2_2"><title>2.2. Practice Exploration</title><p>An experimental transformation of two apartment units in Beijing was demonstrated in the reference [<xref ref-type="bibr" rid="scirp.69696-ref11">11</xref>] how a passive ecological design can become a systematic tactics to transform a conventional residence to a green building by using local natural resources through sunlight room, solar thermal collectors, rainwater collection and interior ecological wall. Reference [<xref ref-type="bibr" rid="scirp.69696-ref12">12</xref>] presented a small low-energy green building located in the suburb of Hangzhou which was designed combining with active and passive methods such as solar energy technologies，enhanced insulation system of envelope and so on. According to the reference [<xref ref-type="bibr" rid="scirp.69696-ref13">13</xref>] , the first passive public building was constructed as a demonstrative project in Changxing county of Zhejiang province by using the “Passive house” standard of Germany for reference, which explored the potential of realizing the low-energy building practice in the hot summer/cold winter region and summarized the construction experience.</p></sec><sec id="s2_3"><title>2.3. Computer Simulation</title><p>Computer simulation is a useful method for architects and engineers to simulate and analyze building performance earlier in the design process. The indoor thermal environment of the residences in Turpan District of Xinjiang was simulated and analyzed by using Ecotect software in the reference [<xref ref-type="bibr" rid="scirp.69696-ref14">14</xref>] to evaluate the thermal performance of primary scheme related to the solar radiation, heating consumption and indoor comfort level. Reference [<xref ref-type="bibr" rid="scirp.69696-ref15">15</xref>] carried out a simulation analysis of indoor hourly temperature towards a library building for the insulation material optimization.</p><p>Based on the above literature, there are very few studies on passive rural residential buildings design in response to the climate of hot summer/cold winter region. In this study, the “passive” design concept was considered firstly through appropriate plan arrangement, building shape optimization and construction materials selection to largely improve indoor thermal comfort and reduce energy consumption. Secondly, affordable technology equipments were integrated in this project for the purpose of gaining renewable energy actively, supplying energy to building and decrease the need of fossil energy. Furthermore, this project is not a real residential building while is an experimental model integrated with various adaptable energy-saving techniques to be studied and investigated or to be modified and changed into more advanced product in future.</p></sec></sec><sec id="s3"><title>3. Passive Design Strategies</title><p>Hangzhou is a typical city in the hot-summer and cold-winter zone. According to the statistic [<xref ref-type="bibr" rid="scirp.69696-ref16">16</xref>] , the average temperature in July was about 30.6˚C in 2006. Especially in July and August, the solar radiation is at the peak, while the maximum temperature occasionally exceeded 40˚C and the minimum was commonly about 28˚C in the view of history after the rainy season, which is an important factor causing the extreme clear and hot high temperature event, leading to the poor indoor thermal environment in the summer of Hangzhou. On the other hand, the average temperature in January was about 4˚C and the relative humidity was about 80% that resulted in the wet and cold indoor environment in winter.</p><p>Based on the above analysis, the design strategies response to the Hangzhou climate should be concluded as following:</p><p>1) to largely gain solar radiation energy and highly enhance envelope insulation in winter;</p><p>2) to induce nature ventilation efficiently and control the amount of solar radiation admitted into the room by using appropriate shading devices in summer.</p><p>As mentioned above, an experimental residential building was designed with the height of 2.8 m and the area of 50 - 60 m<sup>2</sup>, characterized by a symmetrical layout (see <xref ref-type="fig" rid="fig4">Figure 4</xref>): two bedrooms were on the both sides of the living room being oriented south. The other rooms, kitchen and toilet, were at the back of the main rooms facing north. This arrangement is set on a basis that main rooms requiring heating in winter should be at the area with less temperature difference of indoor and outdoor for reducing the heat transferring loss through the building envelope. Several passive design strategies were introduced as following:</p><p>1) The final plan was the result of being simulated and compared by Ecotec software analysis, as illustrated in the session 4, seen in <xref ref-type="fig" rid="fig4">Figure 4</xref>, <xref ref-type="fig" rid="fig5">Figure 5</xref>.</p><p>2) Considering application of thermal pressure ventilation in summer, a patio space was set at the back of the middle room with a rectangular air duct of 4.5 m high above the roof, which connected indoor space with outside environment through a horizontal rectangular inlet opening located on the room ceiling, forming a solar chimney structure. <xref ref-type="fig" rid="fig6">Figure 6</xref> and <xref ref-type="fig" rid="fig7">Figure 7</xref> indicated the side elevation and the structure section sketch respectively. The operation of this passive ventilation system was illustrated in <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p><p>3) In the early study [<xref ref-type="bibr" rid="scirp.69696-ref17">17</xref>] , the solar energy resource of Hangzhou was assessed according to the weather file of Typical Meteorological Year (TMY) of Hangzhou. The result indicated that the solar room should be recommended for the insulation and solar gains in winter towards the construction of rural residences in Hangzhou. The south external wall of the living room was designed with the thermal storage wall combined with glass boxes as the main component for heating the inside room (see <xref ref-type="fig" rid="fig9">Figure 9</xref>). Figure10 and <xref ref-type="fig" rid="fig1">Figure 1</xref>1 represent the operation of such solar collector wall in winter and summer.</p><p>4) For the better utilization of roof as solar energy collector, the session 4 introduced that the Ecotect software was applied to simulate the total solar radiation falling on the middle roof with different angle. At the end, the optical angle was 30˚ combined with the solar chimney for the aesthetic style, shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>.</p><p>5) The popular preference of larger window areas in residential buildings is usually for the better viewing and lighting, but also resulting in the huge energy compensations. The natural optical light system was applied in the living room for reducing the influence of solar radiation. The principle of natural optical light system was shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>2, and the session 4 illustrates the analysis process and predicts the indoor lighting situation adjusting the dimension size of the mental tube and window area.</p><p>6) During the building operation, the external construction is an important way for heat transferring resulting in large amount of energy consumption. Therefore, building envelope insulation deserves high attention including wall, roof and window. In this project, local economically materials and common thermal insulation system were considered, the performance of which were both higher than the president regulation Design standard for energy efficiency of residential buildings in hot summer and cold winter zone banned by the Ministry of Housing and Urban-Rural Development of China. The material and construction method was shown in <xref ref-type="table" rid="table1">Table 1</xref>, and the construction details of roof and wall were displayed in <xref ref-type="fig" rid="fig1">Figure 1</xref>3 and <xref ref-type="fig" rid="fig1">Figure 1</xref>4.</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Plane</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x7.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Design sketch</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x8.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Side elevation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x9.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> The section sketch of the passive ventilation system</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x10.png"/></fig><fig-group id="fig8"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> The operation of passive thermal pressure ventilation in summer (a) Daytime; (b) Nighttime.</title></caption><fig id ="fig8_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x11.png"/></fig><fig id ="fig8_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x12.png"/></fig></fig-group><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> The construction details of solar collector wall</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x13.png"/></fig><fig-group id="fig10"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> The operation of solar collector wall in winter (a) Daytime; (b) Nighttime.</title></caption><fig id ="fig10_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x14.png"/></fig><fig id ="fig10_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x15.png"/></fig></fig-group><fig-group id="fig11"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>1</label><caption><title> The operation of solar collector wall in summer (a) Daytime; (b) Nighttime.</title></caption><fig id ="fig11_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x16.png"/></fig><fig id ="fig11_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x17.png"/></fig></fig-group><fig id="fig12"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>2</label><caption><title> The principle of natural optical light system</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x18.png"/></fig></sec><sec id="s4"><title>4. Tool and Methodology</title><p>The Ecotect software is a useful tool to analyze the variable physical environment and predict the energy consumption through simulating the building, for the further research and optimization on the preliminary scheme. This software was developed for architects and engineers to carry out sustainable analysis on variable physical environment during the conceptual design, including: thermal environment (heating/cooling load, energy consumption simulation, hourly temperature analysis and so on); wind environment (nature ventilation, solar heating and so on); lighting environment (sky illumination, mechanical lighting, nature lighting); sound environment (noise analysis,</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Characteristics and thermal properties of materials used in the design building</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Structural element</th><th align="center" valign="middle" >Structure and construction method (from outside to inside)</th><th align="center" valign="middle" >U-value(W/m<sup>2</sup>・k)/solar heat gain coefficient</th></tr></thead><tr><td align="center" valign="middle" >Wall 1</td><td align="center" valign="middle" >plastic board (10 mm) + rock wool (50 mm) + aerated concrete block (300 mm) + cement-lime mortar (8 mm)</td><td align="center" valign="middle" >0.33</td></tr><tr><td align="center" valign="middle" >Wall 2</td><td align="center" valign="middle" >plain concrete (300 mm)</td><td align="center" valign="middle" >0.96</td></tr><tr><td align="center" valign="middle" >Roof</td><td align="center" valign="middle" >XPS board (70 mm) + Metal deck insulated (80 mm)</td><td align="center" valign="middle" >0.73</td></tr><tr><td align="center" valign="middle" >Ground</td><td align="center" valign="middle" >packed soil (300 mm) + gravel pebble (400 mm) + air layer(500 mm) + fine aggregate concrete (100 mm) + cement mortar (20 mm)</td><td align="center" valign="middle" >0.47</td></tr><tr><td align="center" valign="middle" >Window</td><td align="center" valign="middle" >Low-E glass (6 mm) + air layer (9 mm) + transparent glass (6 mm)</td><td align="center" valign="middle" >2.4/ 0.75</td></tr><tr><td align="center" valign="middle" >Door</td><td align="center" valign="middle" >solid wood door (40 mm)</td><td align="center" valign="middle" >2.71</td></tr></tbody></table></table-wrap><fig id="fig13"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>3</label><caption><title> The principle of natural optical light system</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x19.png"/></fig><fig id="fig14"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>4</label><caption><title> The construction details of the insulation system of the roof</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x20.png"/></fig><p>acoustical design); sunlight environment (sunlight reflector design, shading devices design); economic analysis (cost estimating, resources consumption analysis ); environmental impact and visibility analysis [<xref ref-type="bibr" rid="scirp.69696-ref18">18</xref>] .</p><p>The methodology used in this paper is to establish the building model by Ecotect software based on the Hangzhou weather data, and the building performance (such as indoor thermal environment, indoor lighting environment and solar radiation level) influenced by the variable design conditions are simulated. According to the simulation results, the following are to be discussed and concluded:</p><p>1) Modeling studies on the heat gains/loss or solar radiation gains resulted from different building forms to find the optimum shape.</p><p>2) Modeling studies on the solar radiation access on the roof surface with different angles to find the best incline.</p><p>3) Evaluating the energy consumption difference between the design building and standard building based on monthly cooling/heating loads through modeling simulation.</p><p>4) Calculating the external sunshade coefficient, verifying the energy consumption level adding external shading device or not.</p><p>5) Verifying the indoor lighting level resulted from metal tube optical system, to find the best diameter size and fenestration on the external wall.</p><p>As shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>, the building model was set according to the design scheme (<xref ref-type="fig" rid="fig5">Figure 5</xref> and <xref ref-type="fig" rid="fig6">Figure 6</xref>). For the purpose of comparison, the model building should be assigned with the same basis information (see <xref ref-type="table" rid="table2">Table 2</xref> and <xref ref-type="table" rid="table3">Table 3</xref>) and envelope properties (see <xref ref-type="table" rid="table1">Table 1</xref>), so as to analyze and evaluate the simulating results impacted by different design conditions.</p></sec><sec id="s5"><title>5. Results and Discussion</title><sec id="s5_1"><title>5.1. Building Shape Optimization</title><p>The building Form Coefficient (FC) refers to the ratio of external envelope surface to volume, which influenced the energy consumption greatly. For this reason, FC</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Characteristics and thermal properties of materials used in the design building</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="2"  >Floor area (m<sup>2</sup>)</th><th align="center" valign="middle" >58.9</th></tr></thead><tr><td align="center" valign="middle"  colspan="2"  >Net height (m)</td><td align="center" valign="middle" >2.7</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Construction height (m)</td><td align="center" valign="middle" >7.2</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Bedroom1 (m<sup>2</sup>)</td><td align="center" valign="middle" >9.6</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Bedroom2 (m<sup>2</sup>)</td><td align="center" valign="middle" >9.6</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Living room (including dining room) (m<sup>2</sup>)</td><td align="center" valign="middle" >22</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Kitchen (m<sup>2</sup>)</td><td align="center" valign="middle" >4.9</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Toilet (m<sup>2</sup>)</td><td align="center" valign="middle" >4.9</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Window size ( height &#215; width )</td><td align="center" valign="middle" >South</td><td align="center" valign="middle" >1.5 &#215; 1.2</td></tr><tr><td align="center" valign="middle" >North</td><td align="center" valign="middle" >0.6 &#215; 0.6</td></tr><tr><td align="center" valign="middle" >East</td><td align="center" valign="middle" >1.5 &#215; 1.2</td></tr><tr><td align="center" valign="middle" >West</td><td align="center" valign="middle" >1.5 &#215; 1.2</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Window-wall ratio</td><td align="center" valign="middle" >South</td><td align="center" valign="middle" >0.14</td></tr><tr><td align="center" valign="middle" >North</td><td align="center" valign="middle" >0.02</td></tr><tr><td align="center" valign="middle" >East</td><td align="center" valign="middle" >0.09</td></tr><tr><td align="center" valign="middle" >West</td><td align="center" valign="middle" >0.09</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Operational parameters of equipment</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Room</th><th align="center" valign="middle"  rowspan="2"  >Active system</th><th align="center" valign="middle"  rowspan="2"  >Efficiency</th><th align="center" valign="middle"  colspan="2"  >Comfort band</th><th align="center" valign="middle"  colspan="2"  >Hours of operation</th></tr></thead><tr><td align="center" valign="middle" >Lower band</td><td align="center" valign="middle" >Upper band</td><td align="center" valign="middle" >Week days</td><td align="center" valign="middle" >Week ends</td></tr><tr><td align="center" valign="middle" >Living room</td><td align="center" valign="middle" >Full air conditioning</td><td align="center" valign="middle" >95%</td><td align="center" valign="middle" >18˚C</td><td align="center" valign="middle" >26˚C</td><td align="center" valign="middle" >22 p.m - 8 a.m</td><td align="center" valign="middle" >24 h</td></tr><tr><td align="center" valign="middle" >Bedroom</td><td align="center" valign="middle" >Full air conditioning</td><td align="center" valign="middle" >95%</td><td align="center" valign="middle" >18˚C</td><td align="center" valign="middle" >26˚C</td><td align="center" valign="middle" >22 p.m - 8 a.m</td><td align="center" valign="middle" >24 h</td></tr><tr><td align="center" valign="middle" >Kitchen</td><td align="center" valign="middle" >Nature ventilation</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td></tr><tr><td align="center" valign="middle" >Toilet</td><td align="center" valign="middle" >Nature ventilation</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >――</td></tr></tbody></table></table-wrap><p>should be controlled at a relative low value to prevent additional heat loss. In terms of hot summer/cold winter region, FC is not so critical due to the less temperature difference, meanwhile over tight shape will impact on both architects’ creation and solar heat gains in winter. Therefore, the building models with different plans (see <xref ref-type="fig" rid="fig1">Figure 1</xref>5) but the same floor area and height, were simulated and compared for the balance of heat transferring loss and solar radiation gains. According to the results (see <xref ref-type="table" rid="table4">Table 4</xref>), including the energy consumption, heating loss through envelope and solar energy gains, different building performance were visually reflected by the Figures 16-18.</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref>6 and <xref ref-type="fig" rid="fig1">Figure 1</xref>7 indicate that the annual energy consumption is expected to rise as the FC increasing. As shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>5, the form1 possesses the most simple shape so that the total annual loads is lower than others，while that of form6 is significantly high due to its relatively complex envelope (see <xref ref-type="fig" rid="fig1">Figure 1</xref>7). For the other form, the annual energy consumption presents little difference because of their similar FC. Further simulating results about the ratio of passive solar radiation gains in heating season (i.e. from 1st Nov. to 30th Apr.) and cooling season (i.e. from 1st Jun. to 30th Sep.) together with that of the heating loss through fabric in heating season are shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>8. It can be observed that form1 obtain the lowest solar energy during heating season for the reason of the simplest shape. Although the FC of form 2, 3, 4 and 6 has an increasing tendency, the solar energy gains in winter are not expected so high due to the constant frontage facing to the sun. For the form 5, more compact shape does not contribute in reducing energy consumption because of its bigger deep compare to other models. In addition, it can be observed that the form 3 has relatively low annual loads and high solar heat gains (52%) in winter, while the solar energy obtained in summer is not so high (39.4%). Based on the above discussion, the form 3 was selected as the final plan considering the architecture style design, and the external shading can be provided in summer in case of preventing over solar radiation.</p></sec><sec id="s5_2"><title>5.2. Roof Angle Optimization</title><p>There are two types: In an earlier study [<xref ref-type="bibr" rid="scirp.69696-ref15">15</xref>] , the amount of astronomical solar radiation resulted from the TMY data base of Hangzhou was about 4329 MJ/m<sup>2</sup>, namely 1202 kW∙h/m<sup>2</sup>∙a, where has been identified as the resource-poor area (i.e. between 1160 ~ 1400 kW∙h/m<sup>2</sup>∙a [<xref ref-type="bibr" rid="scirp.69696-ref15">15</xref>] ) of solar energy. According to the evaluation method indicated in the reference [<xref ref-type="bibr" rid="scirp.69696-ref17">17</xref>] , there were 273 days in Hangzhou area where has more than 6 hours sunshine duration in each day, taken as the indictor for assessing the value of solar resource utilization. Therefore, it can be observed that the period between May and September in Hangzhou conforms to the requirement. Based on the above discussion, the solar radiation data from TMY of Hangzhou was put into the basic model to</p><fig id="fig15"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>5</label><caption><title> The comparison of different plans</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x21.png"/></fig><fig id="fig16"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>6</label><caption><title> The profile of calculating results of FC</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x22.png"/></fig><fig id="fig17"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>7</label><caption><title> The simulated annual loads of different forms</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x23.png"/></fig><fig id="fig18"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>8</label><caption><title> The comparison of the ratio of passive components in different seasons</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x24.png"/></fig><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Summary of simulation and calculating</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Name</th><th align="center" valign="middle"  rowspan="2"  >FC</th><th align="center" valign="middle"  colspan="2"  >Soar gains %</th><th align="center" valign="middle" >Fabric losses %</th><th align="center" valign="middle"  rowspan="2"  >Max heating load kW∙h</th><th align="center" valign="middle"  rowspan="2"  >Max cooling load kW∙h</th><th align="center" valign="middle"  rowspan="2"  >Annual loads kW∙h</th></tr></thead><tr><td align="center" valign="middle" >1<sup>st</sup> Jun. to 30<sup>th</sup> Sep.</td><td align="center" valign="middle" >1<sup>st</sup> Nov. to 30<sup>th</sup> Apr.</td><td align="center" valign="middle" >1<sup>st</sup> Nov. to 30<sup>th</sup> Apr.</td></tr><tr><td align="center" valign="middle" >Form1</td><td align="center" valign="middle" >0.888</td><td align="center" valign="middle" >38.80%</td><td align="center" valign="middle" >51.60%</td><td align="center" valign="middle" >71.80%</td><td align="center" valign="middle" >3469</td><td align="center" valign="middle" >3319</td><td align="center" valign="middle" >7498</td></tr><tr><td align="center" valign="middle" >Form2</td><td align="center" valign="middle" >0.902</td><td align="center" valign="middle" >39.50%</td><td align="center" valign="middle" >53.10%</td><td align="center" valign="middle" >73%</td><td align="center" valign="middle" >3606</td><td align="center" valign="middle" >3625</td><td align="center" valign="middle" >7803</td></tr><tr><td align="center" valign="middle" >Form3</td><td align="center" valign="middle" >0.913</td><td align="center" valign="middle" >39.40%</td><td align="center" valign="middle" >52.60%</td><td align="center" valign="middle" >73.60%</td><td align="center" valign="middle" >3613</td><td align="center" valign="middle" >3487</td><td align="center" valign="middle" >7885</td></tr><tr><td align="center" valign="middle" >Form4</td><td align="center" valign="middle" >0.930</td><td align="center" valign="middle" >39.40%</td><td align="center" valign="middle" >53.60%</td><td align="center" valign="middle" >74%</td><td align="center" valign="middle" >3724</td><td align="center" valign="middle" >3657</td><td align="center" valign="middle" >8072</td></tr><tr><td align="center" valign="middle" >Form5</td><td align="center" valign="middle" >0.930</td><td align="center" valign="middle" >40.10%</td><td align="center" valign="middle" >53.70%</td><td align="center" valign="middle" >73.70%</td><td align="center" valign="middle" >3716</td><td align="center" valign="middle" >3653</td><td align="center" valign="middle" >8098</td></tr><tr><td align="center" valign="middle" >Form6</td><td align="center" valign="middle" >0.948</td><td align="center" valign="middle" >42.40%</td><td align="center" valign="middle" >59.40%</td><td align="center" valign="middle" >78.50%</td><td align="center" valign="middle" >4332</td><td align="center" valign="middle" >4079</td><td align="center" valign="middle" >9600</td></tr></tbody></table></table-wrap><p>calculate the total solar radiation falling on the variable angles between 0˚ ~ 50˚, thereby determining the best degree inclination for the solar panel installation.</p><p>As shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>9, the amount of solar radiation falling on the sloped roof indicates an general increasing tendency as the changing degree of inclination: at the range of 0˚ ~ 5˚ angle, the solar heating gains (SHG) is decreasing firstly, and then rising gradually from 5˚ to 35˚ until reaching the peak value of 578.1. After 35˚, SHG appears declining slightly and starts to increase at 50˚. This finding presents that SHG (i.e. from 1st May to 30th Sept.) does not keep increasing constantly with the roof inclining, thus the best angle should be 35˚. <xref ref-type="fig" rid="fig2">Figure 2</xref>0 illustrates the SHG profile as the angle changing of roof inclination during the whole year: it can be observed that SHG gradually rise from 0˚ ~ 30˚ and then increase suddenly at 32˚ where SHG begin to decline until the roof angle become 45˚. Thus it can be concluded that the best angle of roof for SHG between Jan. to Dec. should be 32˚. Generally considering the architecture style and construction, the roof inclined greatly will lead to the structure stability and un comfortable visual effect, so the angle of roof is determined to be 30˚ as the final plan.</p><fig id="fig19"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>9</label><caption><title> The total solar radiation falling on the variable angles between 0˚ ~ 50˚from May to September</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x25.png"/></fig><fig id="fig20"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>0</label><caption><title> The total solar radiation falling on the variable angles between 0˚ ~ 50˚ during the whole year</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x26.png"/></fig></sec><sec id="s5_3"><title>5.3. Effective Factors Analysis of Envelope Insulation System</title><p>The main envelope insulation system including external wall, roof and windows plays the important role on reducing thermal energy and improving indoor comfort. Considering the maximum energy efficiency and the minimum cost, the Ecotect software was used to simulate the variable tendency of annual heating and cooling loads which were the basic indicator of comparison among the wall and roof insulated by different thickness of materials, as well as the window designed various U-value (seen in <xref ref-type="table" rid="table5">Table 5</xref>). It was assumed that the thermal performance of other components remained unchanged while the any one of the components was investigated on influencing the energy loads during the process of simulation. Based upon the precondition, the appropriate U-value of the external wall, roof and window were determined according to the simulating results shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>1 and <xref ref-type="fig" rid="fig2">Figure 2</xref>2.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref>1(a) shows that the energy consumption presents roughly decreasing tendency as the thicknesses of insulation layer constructed on the wall from 0 mm to 100 mm respectively: the heating demand of the external wall insulated by rock wool materials declines significantly by 14.2% (i.e. from 3275.7 kW∙h to 2810.3 kW∙h) compared to the cooling demand from 2278.5 kW∙h to 2190.5 kW∙h, only by 3.9%. It can be observed that total annual energy consumption mainly influenced by heating demand has a general reduction of 10% (i.e. from 5554.2 kW∙h to 5000.9 kW∙h), the profile of which is relatively obvious from 0 mm to 50 mm, but begins to level off after that.</p><p>From the simulation result (<xref ref-type="fig" rid="fig2">Figure 2</xref>1(b)) about roof insulated by XPS board, the cooling demand changes obviously with a 24.6% reduction from 2278.5 kW∙h to 1717.3 kW∙h, relative to the heating energy consumption dropping down by 15.7% (i.e. from 3275. 7 kW∙h to 2761.0 kW∙h); it can also be seen that the annual total demand decreasing by 19.4% from 5554.2 kW∙h to 4478.3 kW∙h is influenced greatly by the cooling demand change, and the value begins to drop slowly when the insulation lay reaches to the thickness of 70 mm. According to the result, roof insulation is the main factor considered to defend solar radiation in summer, which can be explained by the fact that the most solar radiation access is accepted by horizontal plane in Hangzhou area.</p><p>The U-value changing profile of window , illustrated in <xref ref-type="fig" rid="fig2">Figure 2</xref>2, show that the total demand variation is synchronized with that of heating demand: as the U-value changing from 5.4 to 0.5, heating demand falls very rapidly (i.e. with 37.1% reduction from3275.7 kW∙h to 2060.1 kW∙h) causing an overall decline of annual energy demand by 22.%. While the cooling demands profile has almost no change, only with a 2.5% reduction from 2278.5 kW∙h to 2220.5 kW∙h. Based on the figure, it can be concluded that the thermal performance of windows play an important role on the whole energy consumption, especially on reducing heating loss caused by the temperature difference in winter, but has no effect in summer.</p><p>According to the above analysis, the optimal thicknesses of insulation layer for wall and roof were decided as 50 mm and 70 mm respectively. In term of windows, the best U-value was considered as 2.5 processed by double glazing sandwich-type coated Low-E film, a 9 mm air gap layer enclosed between two 6 mm clear glass sheets and insulating aluminum profile.</p><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> The calculated results of U-value for external wall and roof</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >External wall structure (from outside to inside)</th><th align="center" valign="middle" >Insulation layer thickness (mm)</th><th align="center" valign="middle" >U value (w/m<sup>2</sup>・k)</th><th align="center" valign="middle" >Roof structure (from outside to inside)</th><th align="center" valign="middle" >Insulation layer thickness (mm)</th><th align="center" valign="middle" >U value (w/m<sup>2</sup>・k)</th></tr></thead><tr><td align="center" valign="middle"  rowspan="11"  >plastic board (10 mm) + rock wool (d mm) + aerated concrete block (300 mm) + cement-lime mortar (8 mm)</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle"  rowspan="11"  >XPS board (d mm) + metal deck insulated (80 mm)</td><td align="center" valign="middle" >0</td><td align="center" valign="middle" >1.23</td></tr><tr><td align="center" valign="middle" >10</td><td align="center" valign="middle" >0.53</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >1.12</td></tr><tr><td align="center" valign="middle" >20</td><td align="center" valign="middle" >0.46</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >1.03</td></tr><tr><td align="center" valign="middle" >30</td><td align="center" valign="middle" >0.40</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >0.95</td></tr><tr><td align="center" valign="middle" >40</td><td align="center" valign="middle" >0.36</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >0.88</td></tr><tr><td align="center" valign="middle" >50</td><td align="center" valign="middle" >0.33</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >0.82</td></tr><tr><td align="center" valign="middle" >60</td><td align="center" valign="middle" >0.30</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >0.77</td></tr><tr><td align="center" valign="middle" >70</td><td align="center" valign="middle" >0.27</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >0.73</td></tr><tr><td align="center" valign="middle" >80</td><td align="center" valign="middle" >0.25</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >0.69</td></tr><tr><td align="center" valign="middle" >90</td><td align="center" valign="middle" >0.24</td><td align="center" valign="middle" >90</td><td align="center" valign="middle" >0.65</td></tr><tr><td align="center" valign="middle" >10</td><td align="center" valign="middle" >0.22</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >0.62</td></tr></tbody></table></table-wrap><fig-group id="fig21"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>1</label><caption><title> The profile of the annual energy demand changing with: (a) the different insulation thickness of the wall; (b) the different insulation thickness of the roof.</title></caption><fig id ="fig21_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x27.png"/></fig><fig id ="fig21_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x28.png"/></fig></fig-group><fig id="fig22"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>2</label><caption><title> The profile of the annual energy demand changing with different U-value of the window</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x29.png"/></fig><p>Due to the reason that the thermal performance of residential building envelope was definitely regulated in hot-summer/cold-winter region [<xref ref-type="bibr" rid="scirp.69696-ref19">19</xref>] , the optimal values selected before and the those listed in the <xref ref-type="table" rid="table6">Table 6</xref> were assigned to the model for simulating respectively, thereby comparing the energy demand level with each other. At the same time, the effectiveness of insulation design strategies was evaluated.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref>3 indicates that the total energy demand of design building insulated by highly efficient materials is obviously lower than that of standard building, falling down</p><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> The comparison of the optimal values and the regulated in standard about the thermal performance of residential building envelope</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="2"   rowspan="2"  >Component</th><th align="center" valign="middle"  colspan="2"  >Design building</th><th align="center" valign="middle"  colspan="2"  >Standard building</th></tr></thead><tr><td align="center" valign="middle" >U-value (W/m<sup>2</sup>∙K)/ shading coefficient of glasses (SC<sub>B</sub>)</td><td align="center" valign="middle" >Window-wall ratio</td><td align="center" valign="middle" >U-value (W/m<sup>2</sup>∙K)/ Shading coefficient of glasses (SC<sub>B</sub>)</td><td align="center" valign="middle" >Window-wall ratio</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Roof</td><td align="center" valign="middle" >0.73</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >――</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Wall</td><td align="center" valign="middle" >0.33</td><td align="center" valign="middle" >――</td><td align="center" valign="middle" >0.80</td><td align="center" valign="middle" >――</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Window</td><td align="center" valign="middle" >South</td><td align="center" valign="middle" >2.5/0.75</td><td align="center" valign="middle" >0.14</td><td align="center" valign="middle" >4.0/0.94</td><td align="center" valign="middle" >0.14</td></tr><tr><td align="center" valign="middle" >North</td><td align="center" valign="middle" >2.5/0.75</td><td align="center" valign="middle" >0.02</td><td align="center" valign="middle" >4.0/0.94</td><td align="center" valign="middle" >0.02</td></tr><tr><td align="center" valign="middle" >East</td><td align="center" valign="middle" >2.5/0.75</td><td align="center" valign="middle" >0.09</td><td align="center" valign="middle" >4.0/0.94</td><td align="center" valign="middle" >0.09</td></tr><tr><td align="center" valign="middle" >West</td><td align="center" valign="middle" >2.5/0.75</td><td align="center" valign="middle" >0.09</td><td align="center" valign="middle" >4.0/0.94</td><td align="center" valign="middle" >0.09</td></tr></tbody></table></table-wrap><fig id="fig23"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>3</label><caption><title> The comparison of annual energy demand of design building and standard building</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x30.png"/></fig><p>by 14.2% relatively (i.e. from 3760.7 kW∙h to 3228.3 kW∙h). The heating demand profile represents a clear decreasing tendency with 20.7% from 2156.3 kW∙h to 1708.6 kW∙h, while the cooling demand has a slight change from 1604.4 kW∙h to 1519.7 kW∙h, only by 5.3%. The result determined that the objective progress was made in the design building compared to the current regulation.</p></sec><sec id="s5_4"><title>5.4. Effective Factors Analysis of Shading Devices for Windows</title><p>Shading design is the important strategy on heat defending in summer of Hangzhou. Different directions should have corresponding shading measures, such as baffle devices for east or west windows, horizontal rectangular devices for south windows and surrounding shade with verticals for southeast or southwest windows.</p><p>In this project, the metal baffle shading devices made of adjustable horizontal shutters were designed for the east and west external window, shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>4. For the south window, the best shading devices should be the horizon sun shield due to the reason of Hangzhou location which is on the north of Tropic of Cancer. The size of shading shield can be calculated on the base of the solar altitude and azimuth angles. Firstly, the sun path and control in summer indicate that the horizontal size will be in the large value with solar altitude angle increasing when the sun moves at midday. Otherwise, the wing size of the shield could be decided by the directions of the solar rays, which is get longer as the sun set. In order to fit the facade configuration, the surrounding shade with verticals was selected in the phase of preliminary design, and then the detailed size will be get by using calculation software. For Hangzhou area, the hottest days in a year are usually from May to September when the maximum solar radiation of each day occurs at the range of 10:00 a.m. to 4:00 p.m. [<xref ref-type="bibr" rid="scirp.69696-ref17">17</xref>] . In Ecotect software, the minimum shading size was created automatically according to the input information including date range and time range mentioned above (see <xref ref-type="fig" rid="fig2">Figure 2</xref>5). By the consideration of shading efficiency and architecture design, the final size of horizontal and vertical shield were both 450 mm, shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>6.</p><p>Normally, integrated shading coefficient of external window (SC) is the important indicator to evaluate the shading effect, relevant to the following factors: shading coefficient of external devices (SD), the shading coefficient of glasses (SCB) and the frame-window area ratio (FK/FC). The formula1 indicates the computing methods about the SC and SD. For the shading configuration designed for east or west window, SC can be calculated by the formula directly; but for the composed device, the value of SD should be the product of that get from horizontal shield and vertical shield respectively. The calculating results are shown in Tables 7-10.</p><disp-formula id="scirp.69696-formula2"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/1-1260153x31.png"  xlink:type="simple"/></disp-formula><p>After determining the shading devices style, Ecotect software was used to test the design effect through simulating the monthly cooling demand in TMY. The following design conditions were considered, and the results were shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>7:</p><p>The solar gain coefficient of glasses is 0.75, and has no any external shading devices;</p><p>Only east and west windows were provided with the metal baffle shading devices made of adjustable horizontal shutters, the value of SC seen in <xref ref-type="table" rid="table1">Table 1</xref>0;</p><p>Only south windows were provided with integrated shading devices composed of horizontal and vertical shied , the value of SC seen in <xref ref-type="table" rid="table1">Table 1</xref>0;</p><p>All the windows were considered with external shading devices, the value of SC seen in <xref ref-type="table" rid="table1">Table 1</xref>0;</p><p>Otherwise, the monthly heating demand in TMY was also simulated under these two conditions, and the results were shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>8:</p><p>The solar gain coefficient of glasses is 0.75, and has no any external shading devices;</p><p>Only south windows were provided with integrated shading devices composed of horizontal and vertical shied , the value of SC seen in <xref ref-type="table" rid="table1">Table 1</xref>0;</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref>7 indicates that the annual cooling demand has an obvious decrease when only the east and west windows were designed with external shading devices comparing to that being installed outside the south windows only during May to September: especially in May, the cooling demand consumed by the former drops about 13.2% from 100.2 kW∙h to 87.1 kW∙h, while that consumed by the later only 2.4% (i.e. from 100.3 kW∙h to 98.0 kW∙h). When all the windows use the external sun-shading, the cooling consumption falls down by 14.7% from 100.3 kW∙h to 85.6 kW∙h. Even in July, the hottest month in Hangzhou, the cooling demand also has a declination of 8.6% under east and west shading consideration only, which can be seen that the eastern or western shading design is an important technological strategy in summer of Hangzhou.</p><p>In the heating season of Hangzhou, namely from November to next April, the</p><fig id="fig24"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>4</label><caption><title> Characteristic value of horizontal shutters</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x32.png"/></fig><fig-group id="fig25"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>5</label><caption><title> The configuration of shading device for south window: (a) minimum size generated by software; (b) final designing configuration.</title></caption><fig id ="fig25_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x34.png"/></fig><fig id ="fig25_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x33.png"/></fig></fig-group><fig-group id="fig26"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>6</label><caption><title> The characteristic of surrounding shade with verticals: (a) the cross section; (b) the flat section.</title></caption><fig id ="fig26_1"><label>(b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x35.png"/></fig><fig id ="fig26_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x36.png"/></fig></fig-group><fig id="fig27"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>7</label><caption><title> Comparison of annual cooling demand under different solar shading design</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x37.png"/></fig><p>heating demand almost remain unchanged when south windows adopt fixes shading devices, shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>8: in January, February and December, the value of heating consumption increases slightly as solar energy gains are affected by the external shield, and that in other months rarely changes.</p><p>For the further analysis and comparison, the annual heating and cooling demand generated by different shading proposals were presented in <xref ref-type="fig" rid="fig2">Figure 2</xref>9. When outside shading just used in east and west windows, the annual cooling demand drops by 10.2%</p><table-wrap id="table7" ><label><xref ref-type="table" rid="table7">Table 7</xref></label><caption><title> Fitting coefficient</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Shading type</th><th align="center" valign="middle"  colspan="2"  >Fitting coefficient</th><th align="center" valign="middle" >East</th><th align="center" valign="middle" >West</th><th align="center" valign="middle" >South</th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >Adjustable horizontal shutters</td><td align="center" valign="middle"  rowspan="2"  >Summer</td><td align="center" valign="middle" >a</td><td align="center" valign="middle" >0.56</td><td align="center" valign="middle" >0.57</td><td align="center" valign="middle" >―</td></tr><tr><td align="center" valign="middle" >b</td><td align="center" valign="middle" >−1.30</td><td align="center" valign="middle" >−1.30</td><td align="center" valign="middle" >―</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Fixed horizontal shield</td><td align="center" valign="middle"  colspan="2"  >a</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >0.5</td></tr><tr><td align="center" valign="middle"  colspan="2"  >b</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >−0.8</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Fixed vertical shield</td><td align="center" valign="middle"  colspan="2"  >a</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >0.33</td></tr><tr><td align="center" valign="middle"  colspan="2"  >b</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >―</td><td align="center" valign="middle" >−0.72</td></tr></tbody></table></table-wrap><p>Data source: Design Standard Energy Efficiency of Residential Building in Hot Summer and Cold Winter Zone JGJ 134 - 2010.</p><table-wrap id="table8" ><label><xref ref-type="table" rid="table8">Table 8</xref></label><caption><title> Calculated results of SD for east/west window</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Season</th><th align="center" valign="middle"  colspan="2"  >SD<sup>a</sup></th></tr></thead><tr><td align="center" valign="middle" >East</td><td align="center" valign="middle" >West</td></tr><tr><td align="center" valign="middle" >Summer</td><td align="center" valign="middle" >0.26</td><td align="center" valign="middle" >0.27</td></tr></tbody></table></table-wrap><table-wrap id="table9" ><label><xref ref-type="table" rid="table9">Table 9</xref></label><caption><title> Calculated results of SD for south windows</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="3"  >Shading type</th><th align="center" valign="middle" >SD<sup>a</sup></th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >Fixed horizontal shield</td><td align="center" valign="middle" >A</td><td align="center" valign="middle" >450</td><td align="center" valign="middle"  rowspan="2"  >0.98</td></tr><tr><td align="center" valign="middle" >B</td><td align="center" valign="middle" >1580</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Fixed vertical shield</td><td align="center" valign="middle" >A</td><td align="center" valign="middle" >450</td><td align="center" valign="middle"  rowspan="2"  >0.78</td></tr><tr><td align="center" valign="middle" >B</td><td align="center" valign="middle" >1200</td></tr><tr><td align="center" valign="middle"  colspan="3"  >Integrated shading device<sup>b</sup></td><td align="center" valign="middle" >0.76</td></tr></tbody></table></table-wrap><p>a. SD=ax<sup>2</sup>+bx+1, x=A/B; b. the product of SD calculated for horizontal shield and for vertical shield respectively.</p><table-wrap id="table10" ><label><xref ref-type="table" rid="table1">Table 1</xref>0</label><caption><title> Calculated results of SC for south windows</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >SC<sup>a</sup></th><th align="center" valign="middle" >East</th><th align="center" valign="middle" >West</th><th align="center" valign="middle" >South</th></tr></thead><tr><td align="center" valign="middle" >Summer</td><td align="center" valign="middle" >0.156</td><td align="center" valign="middle" >0.162</td><td align="center" valign="middle" >0.46</td></tr></tbody></table></table-wrap><p>a. SC = SD &#215; SCC, SCC = SCB &#215; (1 − FK/FC); SCB = 0.75, FK/FC = 0.2, then SCC = 0.6</p><fig id="fig28"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>8</label><caption><title> Comparison of annual heating demand under different solar shading design</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x38.png"/></fig><p>(i.e. from 1517.9 kW∙h to 1363.3 kW∙h), resulting in a 4% reduction of annual total energy consumption, which is more than prominently it is made by the south windows installed with external shield only, annual cooling consumption decreasing by 2.6% while the total annual energy consumption falling by less than 1%. The highest energy saving occur when all the windows possess the outside sun-shading and a significant difference between heating and cooling demand was illustrated that the former rises by 2.5% but the later drops by 12.6%.</p><p>Based upon those findings, in order to achieve the maximum energy efficiency through shading design in terms of Hangzhou climate, the external windows should have adjustable sun-shade devices. For the east and west window in this building, the metal baffle made of adjustable horizon shutters should be closed in summer season and open in winter time. On the other hand, the fixed shading shield is not appropriate for south windows. In this project, shading design could be modified as such way: the cantilever size of 450 mm with adjustable inside vertical shutters, which will either play a shading role effectively in summer or help to solar heating gains in winter.</p></sec><sec id="s5_5"><title>5.5. Analysis and Optimization of Nature Lighting</title><p>The lighting quantity of the middle room was simulated and analyzed by using Ecotect software in order to demonstrate the effectiveness of the nature optical lighting system. Simulating conditions for lighting quantity was decided based on the Standard for Daylighting Design of Buildings (GB50033-2013), as shown in <xref ref-type="table" rid="table1">Table 1</xref>1. According to the standard: Hangzhou city belongs to the IV daylight climate in China, the regulated average value of daylight factor should not be less than 1.1% under the top lighting condition, and the average illuminance of interior daylight should not be less than 165 lx. In terms of the following design conditions, the indoor day-lighting simulating was carried out: when no day-lighting windows on the external wall, the values of daylight factor and illumination were simulated as the changing of the metal optical tube diameter from 500mm to 1000mm with an increase of 100 mm, as shown in <xref ref-type="table" rid="table1">Table 1</xref>2.</p><p>It can be seen in <xref ref-type="table" rid="table1">Table 1</xref>1, the indoor average day lighting factor only add up to 0.66% as the tube diameter increasing from 500 mm to 1000 mm; on the other hand, oversize length will add the difficulty to the structure and influence the visual result. Therefore, single optical tubular system could not meet the requirement of the indoor day-lighting without the additional lighting openings. By overall consideration, the south wall was the only available component to be established with day-lighting opening, which was designed by 1500 mm wide and 500 mm high. The new simulated</p><table-wrap id="table11" ><label><xref ref-type="table" rid="table1">Table 1</xref>1</label><caption><title> Simulating conditions</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Transmittance of tubular day-lighting system</th><th align="center" valign="middle" >Transmittance of window</th><th align="center" valign="middle" >Reflectance of wall</th><th align="center" valign="middle" >Reflectance of ceiling</th><th align="center" valign="middle" >Reflectance of floor</th><th align="center" valign="middle" >Outdoor illumination design value</th></tr></thead><tr><td align="center" valign="middle" >0.8</td><td align="center" valign="middle" >0.6</td><td align="center" valign="middle" >0.8</td><td align="center" valign="middle" >0.8</td><td align="center" valign="middle" >0.65</td><td align="center" valign="middle" >13500 lx</td></tr></tbody></table></table-wrap><p>results obtained from the modified model was shown as <xref ref-type="fig" rid="fig3">Figure 3</xref>0: by comparison to the and the average illumination was 166 lx. Thus, the design of 1000 mm diameter optical model only designed tubular optical system, the average day lighting factor was 1.16% tubular system combined with 100 mm &#215; 500 mm day-lighting opening would satisfy the standard.</p><table-wrap id="table12" ><label><xref ref-type="table" rid="table1">Table 1</xref>2</label><caption><title> The values of daylight factor and illumination</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Diameter (mm)</th><th align="center" valign="middle" >Average day lighting factor (%)</th><th align="center" valign="middle" >Average illumination (lx)</th></tr></thead><tr><td align="center" valign="middle" >500</td><td align="center" valign="middle" >0.21</td><td align="center" valign="middle" >28.15</td></tr><tr><td align="center" valign="middle" >600</td><td align="center" valign="middle" >0.28</td><td align="center" valign="middle" >37.56</td></tr><tr><td align="center" valign="middle" >700</td><td align="center" valign="middle" >0.36</td><td align="center" valign="middle" >48.55</td></tr><tr><td align="center" valign="middle" >800</td><td align="center" valign="middle" >0.45</td><td align="center" valign="middle" >60.38</td></tr><tr><td align="center" valign="middle" >900</td><td align="center" valign="middle" >0.55</td><td align="center" valign="middle" >73.81</td></tr><tr><td align="center" valign="middle" >1000</td><td align="center" valign="middle" >0.66</td><td align="center" valign="middle" >88.55</td></tr></tbody></table></table-wrap><fig id="fig29"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref>9</label><caption><title> Comparison of annual energy demand under different solar shading design</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x39.png"/></fig><fig-group id="fig30"><label><xref ref-type="fig" rid="fig3">Figure 3</xref>0</label><caption><title> Results of nature lighting simulation (a) Only tubular day-lighting system designed; (b) Extra window designed.</title></caption><fig id ="fig30_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x41.png"/></fig><fig id ="fig30_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1260153x40.png"/></fig></fig-group></sec></sec><sec id="s6"><title>6. Conclusions</title><p>As a whole, building construction elements play a significant role in terms of energy consumption and indoor thermal environment, which is restricted by the location, climatic conditions and physical properties of the building. Therefore, the rural residences in the hot summer/cold winter region should be designed economically and appropriately according to the local conditions, moreover be identical with the requirement of ecological sustainable development. In this study, several design strategies provided in a rural residence building for reducing annual energy demand in hot summer/cold winter were introduced and analyzed. By the computer simulating method, some helpful energy-saving design methods were summarized as following:</p><p>1) In terms of hot summer/cold winter region, the best optimized energy-saving shape should be considered to minimize the concave-convex change in order to absorb more solar radiation, which has been analyzed and determined by simulation.</p><p>2) It can be concluded that the appropriated angle of the roof was 30˚, which was beneficial to make the most of the solar energy under the radiation condition of Hangzhou.</p><p>3) Through simulating the annual energy demand, the best thick of insulation layer for the wall and roof, as well as the optical U-value for the window were determined. It can be seen that the annual total energy demand resulted from the design building had a 14.2% reduction compared with the current regulated energy-saving building.</p><p>4) The shading devices played an important role in defending solar radiation in summer. Through calculating and simulating, the shading configurations for the east/ west and south window were determined: the horizontal shutters were applied in east/west window, and the fixed horizontal shading device combined with light blocking curtain inside was used for the south window.</p><p>5) Through simulation and analysis, the day-lighting design standard could be satisfied by combining optical tubular system with side lighting.</p><p>Generally, design working efficiency can be improved greatly if the passive design strategies could be considered in the pre-design process by simulating methods. Through research and analysis, this study is intended to stimulate awareness of energy efficient factors and encourage the integration of these factors into the design and construction of new or renovated rural residential building in the future.</p></sec><sec id="s7"><title>Acknowledgements</title><p>This work was supported by the Department of Education of Zhejiang Province of China (No. FX2014064).</p></sec><sec id="s8"><title>Cite this paper</title><p>Wu, Q. and Gao, W.J. (2016) Research on Passive Design Optimization about an Experimental Rural Residence in Hot Summer and Cold Winter Region of China. Journal of Building Construction and Planning Research, 4, 131-156. http://dx.doi.org/10.4236/jbcpr.2016.43009</p></sec></body><back><ref-list><title>References</title><ref id="scirp.69696-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Building Energy Conservation Research Center of Tsinghua University (2012) Annual Development Report on Building Energy Efficiency of China in 2012. Beijing.</mixed-citation></ref><ref id="scirp.69696-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, Y.M. and Liu, J.P. (2007) Exploration of Optimization Measures for Energy Saving Technology of Urban Residential Buildings. Industrial Construction, 37, 1-4.</mixed-citation></ref><ref id="scirp.69696-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Liu, J.L., Chen, W. and Tan, C.Y. (2010) Research Status on Energy Saving Technology of Rural Residential Buildings. Sichuan Building Science, 36, 241-243.</mixed-citation></ref><ref id="scirp.69696-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Hangzhou City Bureau of Statistics. Online Source. http://www.hzstats.gov.cn</mixed-citation></ref><ref id="scirp.69696-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Wang, M.Y., Ma, J.S. and Wu, Q.C. (2011) Study on the Actual Condition of the Rural Housing and the Application of New Building Materials in Rural Housing, Zhejiang province. Huazhong Architecture, No. 2, 45-47.</mixed-citation></ref><ref id="scirp.69696-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Jin, W. Ge, J. and Zhou, X. (2012) Study on the Living Environment and Building Energy Consumption of Rural Areas in Hangzhou. Huazhong Architecture, No. 1, 30-34.</mixed-citation></ref><ref id="scirp.69696-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Soussi, M., Balghouthi, M. and Guizani, A. (2013) Energy Performance Analysis of a Solar- Cooled Building in Tunisia: Passive Strategies Impact and Improvement Techniques. Energy and Buildings, 67, 374-386. http://dx.doi.org/10.1016/j.enbuild.2013.08.033</mixed-citation></ref><ref id="scirp.69696-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Peng, M.Y. (2011) The Feasibility Study of the Application of the Passive House in the Northern Area and Hot-Summer and Cold-Winter Region of China. Construction Science and Technology, No. 5, 48-54.</mixed-citation></ref><ref id="scirp.69696-ref9"><label>9</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Zhan</surname><given-names> L. </given-names></name>,<etal>et al</etal>. (<year>2010</year>)<article-title>Theory and Practice on Energy-Saving Technology of Residential Building in Hot Summer and Cold Winter of China</article-title><source> Sichuan Building Science</source><volume> 36</volume>,<fpage> 264</fpage>-<lpage>267</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.69696-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Wang, L., Tian, W.L. and Wang, L.J. (2011) Studies on the Design of Passive Solar Ecological Residence. Industrial Construction, 41, 53-70.</mixed-citation></ref><ref id="scirp.69696-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Yu, K.J. and Song, B.M. (2010) Low-Carbon Building—Transformation Design of Beijing Heshi Department. Architecture Journal, No. 8, 33-36.</mixed-citation></ref><ref id="scirp.69696-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Li, J.N. (2007) Design and Practice on a Low-Energy Ecological Residence in Hot Summer and Cold Winter Region. Architecture Journal, No. 11, 16-18.</mixed-citation></ref><ref id="scirp.69696-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Wang, J. (2014) Design and Practice on the Brook Passive House in Changxing. Construction Science and Technology, No. 19, 31-36.</mixed-citation></ref><ref id="scirp.69696-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Ren, J. and Wang, W.J. (2015) Using Ecotect Software to Simulation and Analysis on Indoor Thermal Environment of Herders’ Residential Houses in Turpan Area of Xinjiang. Sichuan Building Science, 41, 295-299.</mixed-citation></ref><ref id="scirp.69696-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Sun, S., Liang, J. and Sun, C. (2015) The Research of Digital Simulation Technique Applied in the Simulation of Energy-Saving in Library Exterior-Protected Construction. Digital Tectonic Culture, 268-273.</mixed-citation></ref><ref id="scirp.69696-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Hangzhou Meteorology. Online Source. http://www.hzqx.gov.cn/</mixed-citation></ref><ref id="scirp.69696-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Yan, Y., Ge, J., Zhu, Y.H., Zhu, T.T. and Shen, T.T. (2015) Methods on Solar Energy Utilization of Hangzhou Countryside Dwellings During the Urbanization Process. Urban Problems, No. 3, 38-43.</mixed-citation></ref><ref id="scirp.69696-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Shou, L.L. (2013) Comparative Research on Building Energy Consumption Analysis Based on BIM with Traditional Building Energy Consumption Analysis of China. Chongqing University, Chongqing.</mixed-citation></ref><ref id="scirp.69696-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Ministry of Construction of the People's Republic of China (2010) Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Cold Winter Zone (JGJ 234-2010). Ministry of Construction of the People's Republic of China, Beijing.</mixed-citation></ref></ref-list></back></article>