<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JPEE</journal-id><journal-title-group><journal-title>Journal of Power and Energy Engineering</journal-title></journal-title-group><issn pub-type="epub">2327-588X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jpee.2016.47002</article-id><article-id pub-id-type="publisher-id">JPEE-69354</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Applications of Low-Emissivity Hybrid Insulation in South Korea
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Young</surname><given-names>Cheol Kwon</given-names></name><xref ref-type="aff" rid="aff1"><sub>1</sub></xref></contrib></contrib-group><aff id="aff1"><label>1</label><addr-line>Department of Architecture, Halla Universtiy, Wonju, South Korea</addr-line></aff><author-notes><corresp id="cor1">* E-mail:</corresp></author-notes><pub-date pub-type="epub"><day>25</day><month>07</month><year>2016</year></pub-date><volume>04</volume><issue>07</issue><fpage>8</fpage><lpage>14</lpage><history><date date-type="received"><day>24</day>	<month>April</month>	<year>2016</year></date><date date-type="rev-recd"><day>accepted</day>	<month>16</month>	<year>July</year>	</date><date date-type="accepted"><day>19</day>	<month>July</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Low-Emissivity Hybrid Insulation has been developed in South Korea. It combines both resistive and reflective insulating principle. It is composed with many layers of reflective aluminum foils and honeycomb-structure air cells with polyethylene foam. This paper introduces recent South Korean building insulation code and the applications of Low-Emissivity Hybrid Insulation to meet the code.
 
</p></abstract><kwd-group><kwd>Low-Emissivity Hybrid Insulation</kwd><kwd> Building Energy Saving</kwd><kwd> Building Insulation Code</kwd><kwd>  Insulation Application</kwd><kwd> Overall Thermal Transmittance</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Low-Emissivity Hybrid Insulation is a multilayer product consisting of layers of aluminum foil and a honey- comb structure produced from polyethylene foam. The resulting structure creates reflective airspaces within the cavity that reduce radiant heat transfer and heat flow by convection. The use of aluminum foil ensures a minimum 95% reduction in radiation across the enclosed regions.</p><p>Low-Emissivity Hybrid Insulation has a foil surface emissivity of 0.04 with enclosed air cells between foils. Its core material is polyethylene foam with 35 times expansion, which is expanded to make air cells. The enclosed air cells with foil reduce convective and radiative heat transfer [<xref ref-type="bibr" rid="scirp.69354-ref1">1</xref>].</p><p><xref ref-type="fig" rid="fig1">Figure 1</xref> shows a 20 mm-thick Low-Emissivity Hybrid Insulation structure.</p><p>As Low-Emissivity Hybrid Insulation is not a homogeneous material, it is impossible to measure its thermal conductivity. Its insulating performance is measured by a Hot Box Test in accordance with ISO 8990 (Thermal Insulation-Determination of steady-state thermal transmission properties-Calibrated and guarded hot box).</p><p>It is necessary to verify the thermal resistance of its constitution materials to improve the insulating perfor- mance of Low-Emissivity Insulation.</p><p>This paper discusses the insulating characteristics of Low-Emissivity Hybrid Insulation depending on heat transfer paths and materials. Low-Emissivity Hybrid Insulation is composed of separated reflective air cells and polyethylene foam partitions between low-emissivity aluminum foils as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. This means that Low-Emissivity Hybrid Insulation is divided into two parts according to the heat transfer paths such as reflective</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> 20 mm-Thick low-emissivity hybrid insulation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/69354x4.png"/></fig><p>air cell and conductive polyethylene foam. Comprehensive thermal transmittance tests were conducted for the Low-Emissivity Hybrid Insulation of specimens of various thicknesses. The thicknesses of the specimens were 10, 20, 30, 40, 50, 60, 80, and 100 mm. Based on the test results, its insulation-affecting factors were in-vesti- gated using a trial-and-error method.</p></sec><sec id="s2"><title>2. Insulating Performance of Low-Emissivity Hybrid Insulation</title><p>To verify the high efficiency of Low-Emissivity Hybrid Insulation, it was tested by an accredited laboratory designated by the South Korean government. Comprehensive thermal transmittance tests were conducted for the Low-Emissivity Hybrid Insulation of specimens of various thicknesses. The thicknesses of the specimens were 10, 20, 30, 40, 50, 60, 80, and 100 mm. The comprehensive thermal transmittance test was conducted in accordance with ISO 8990 (Thermal Insulation-Determination of Steady-State Thermal Transmission Properties-Ca- librated and Guarded Hot Box). <xref ref-type="fig" rid="fig2">Figure 2</xref> shows a drawing of the test specimen.</p><p>The test specimen size is 1500 mm &#215; 1500 mm. <xref ref-type="fig" rid="fig3">Figure 3</xref> shows the locations of the temperature sensors.</p><p>To get more accurate measurement results, three temperature sensors were located at each point. The temperature at each point was determined by averaging the three measured values.</p><p>The hot box facility was calibrated using a polystyrene foam board whose thermal conductivity had been acquired from a heat flow meter apparatus test at an accredited laboratory designated by KOLAS, the South Korea Laboratory Accreditation Scheme.</p><p>Tests were conducted with a hot region temperature of 20˚C and a cold region temperature of 0˚C. The heat flow rate from the hot region to the cold region is determined from energy input to the hot region as in the case with ASTM C 1363. The overall thermal transmittance was calculated after steady-state conditions had been achieved. Data were recorded three times every hour and averaged. The overall thermal transmittance (U) can be obtained from Equation (1) [<xref ref-type="bibr" rid="scirp.69354-ref2">2</xref>].</p><disp-formula id="scirp.69354-formula403"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/69354x5.png"  xlink:type="simple"/></disp-formula><p>U: Overall thermal transmittance (W/m<sup>2</sup>∙K).</p><p>R: Overall thermal resistance (m<sup>2</sup>∙K/W).</p><p>Q: Supplied heat (W).</p><p>Th: Temperature of hot region (˚C).</p><p>Tc: Temperature of cold region (˚C).</p><p>A: Area of specimen (m<sup>2</sup>).</p><p>Test results are shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><p><xref ref-type="table" rid="table1">Table 1</xref> shows that a 100 mm thick Low-Emissivity Hybrid Insulation can meet the overall thermal transmittance of walls and roofs of Passive Houses which is below 0.15 W/m<sup>2</sup>∙K [<xref ref-type="bibr" rid="scirp.69354-ref5">5</xref>].</p><p><xref ref-type="fig" rid="fig4">Figure 4</xref> shows the required thickness of various insulations to meet the overall thermal transmittance of</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Drawing of the test specimen</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/69354x6.png"/></fig><p>Passive Houses of 0.15 W/m<sup>2</sup>∙K.</p><p>While as thick as 240 mm of EPS, whose thermal conductivity is 0.036 W/mK, should be used, as thick as 30 mm of Enervac, which is a kind of a vacuum insulation panel, can be used as insulation for Passive Houses [<xref ref-type="bibr" rid="scirp.69354-ref6">6</xref>]. From <xref ref-type="table" rid="table1">Table 1</xref> and <xref ref-type="fig" rid="fig4">Figure 4</xref>, we can assume that Low-Emissivity Hybrid Insulation has the same insulating performance as Aerogel.</p></sec><sec id="s3"><title>3. Low-Emissivity Hybrid Insulation Thickness to Meet the Required U-Values by South Korean Building Insulation Code</title><p><xref ref-type="table" rid="table2">Table 2</xref> shows required U-values for central region by South Korean building insulation codes [<xref ref-type="bibr" rid="scirp.69354-ref7">7</xref>].</p><p><xref ref-type="table" rid="table2">Table 2</xref> indicates that required U-value for exterior wall adjacent to outside directly should be less than 0.36 W/m<sup>2</sup>∙K. For the designer’s convenience, the building insulation codes provide the required insulation thickness according to each insulation grade. <xref ref-type="table" rid="table3">Table 3</xref> shows the required thickness of insulation to obtain the required U-values.</p><p>The insulation grade is given as A, B, C, D according to thermal conductivity of insulation.</p><p><xref ref-type="table" rid="table4">Table 4</xref> shows how the grade is determined.</p><p><xref ref-type="table" rid="table4">Table 4</xref> indicates, for example, that XPS, Neopor, PU and high-density Glass Wool belong to Grade “A”.</p><p>According to <xref ref-type="table" rid="table3">Table 3</xref> and <xref ref-type="table" rid="table4">Table 4</xref>, Existing insulations should be used as thick as 85 mm or 100 mm for an exterior wall which is adjacent to outside directly for central region in South Korea.</p><p>On the bases of the test results in <xref ref-type="table" rid="table2">Table 2</xref>, 30 mm or 40 mm Low-Emissivity Hybrid Insulation can meet the required U value for the same wall. This means that the thickness of Low-Emissivity Hybrid Insulation required to meet building codes is less than that of many competing insulations.</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Location of the temperature sensors</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/69354x7.png"/></fig><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Required thickness of various insulations for passive houses</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/69354x8.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Overall thermal transmittance and thermal resistance of low-emissivity hybrid insulation [<xref ref-type="bibr" rid="scirp.69354-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.69354-ref4">4</xref>]</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Thickness (mm)</th><th align="center" valign="middle"  rowspan="2"  >Overall thermal transmittance (W/m<sup>2</sup>∙K)</th><th align="center" valign="middle"  colspan="2"  >Thermal resistance</th></tr></thead><tr><td align="center" valign="middle" >(m<sup>2</sup>∙K/W)</td><td align="center" valign="middle" >(ft<sup>2</sup>˚Fhr/Btu)</td></tr><tr><td align="center" valign="middle" >10</td><td align="center" valign="middle" >1.12</td><td align="center" valign="middle" >0.89</td><td align="center" valign="middle" >5.10</td></tr><tr><td align="center" valign="middle" >20</td><td align="center" valign="middle" >0.55</td><td align="center" valign="middle" >1.82</td><td align="center" valign="middle" >10.3</td></tr><tr><td align="center" valign="middle" >30</td><td align="center" valign="middle" >0.45</td><td align="center" valign="middle" >2.22</td><td align="center" valign="middle" >12.6</td></tr><tr><td align="center" valign="middle" >40</td><td align="center" valign="middle" >0.32</td><td align="center" valign="middle" >3.13</td><td align="center" valign="middle" >17.8</td></tr><tr><td align="center" valign="middle" >50</td><td align="center" valign="middle" >0.27</td><td align="center" valign="middle" >3.70</td><td align="center" valign="middle" >21.0</td></tr><tr><td align="center" valign="middle" >60</td><td align="center" valign="middle" >0.22</td><td align="center" valign="middle" >4.55</td><td align="center" valign="middle" >25.8</td></tr><tr><td align="center" valign="middle" >80</td><td align="center" valign="middle" >0.19</td><td align="center" valign="middle" >5.26</td><td align="center" valign="middle" >29.9</td></tr><tr><td align="center" valign="middle" >100</td><td align="center" valign="middle" >0.14</td><td align="center" valign="middle" >7.14</td><td align="center" valign="middle" >40.5</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Required u-values for the central region of South Korea</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="3"  >Building envelope</th><th align="center" valign="middle" >Required U-value (W/m<sup>2</sup>∙K)</th></tr></thead><tr><td align="center" valign="middle"  rowspan="2"  >Exterior wall</td><td align="center" valign="middle"  colspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >Less than 0.36</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >Less than 0.49</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Roof</td><td align="center" valign="middle"  colspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >Less than 0.20</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >Less than 0.29</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Floor of the lowest floor</td><td align="center" valign="middle"  rowspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >Floor heating</td><td align="center" valign="middle" >Less than 0.30</td></tr><tr><td align="center" valign="middle" >No floor heating</td><td align="center" valign="middle" >Less than 0.41</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >Floor heating</td><td align="center" valign="middle" >Less than 0.43</td></tr><tr><td align="center" valign="middle" >No floor heating</td><td align="center" valign="middle" >Less than 0.58</td></tr><tr><td align="center" valign="middle"  colspan="3"  >Sidewall of apartment building</td><td align="center" valign="middle" >Less than 0.27</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Floor between levels</td><td align="center" valign="middle"  colspan="2"  >Floor heating</td><td align="center" valign="middle" >Less than 0.81</td></tr><tr><td align="center" valign="middle"  colspan="2"  >No floor heating</td><td align="center" valign="middle" >Less than 1.16</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Fenetrations and doors</td><td align="center" valign="middle"  rowspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >Apartment</td><td align="center" valign="middle" >Less than 2.10</td></tr><tr><td align="center" valign="middle" >Others</td><td align="center" valign="middle" >Less than 2.40</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >Apartment</td><td align="center" valign="middle" >Less than 2.80</td></tr><tr><td align="center" valign="middle" >Others</td><td align="center" valign="middle" >Less than 3.20</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Required thickness of insulation for central region</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  colspan="3"   rowspan="2"  >Required insulation thickness according to Grade Building envelope</th><th align="center" valign="middle"  colspan="4"  >Thickness (mm)</th></tr></thead><tr><td align="center" valign="middle" >A</td><td align="center" valign="middle" >B</td><td align="center" valign="middle" >C</td><td align="center" valign="middle" >D</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Exterior wall</td><td align="center" valign="middle"  colspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >85</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >115</td><td align="center" valign="middle" >130</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >90</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Floor of the lowest floor</td><td align="center" valign="middle"  rowspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >Floor heating</td><td align="center" valign="middle" >105</td><td align="center" valign="middle" >125</td><td align="center" valign="middle" >140</td><td align="center" valign="middle" >160</td></tr><tr><td align="center" valign="middle" >No floor heating</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >90</td><td align="center" valign="middle" >100</td><td align="center" valign="middle" >115</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >Floor heating</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >90</td><td align="center" valign="middle" >105</td></tr><tr><td align="center" valign="middle" >No floor heating</td><td align="center" valign="middle" >50</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >65</td><td align="center" valign="middle" >70</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Roof</td><td align="center" valign="middle"  colspan="2"  >Adjacent to outside directly</td><td align="center" valign="middle" >160</td><td align="center" valign="middle" >190</td><td align="center" valign="middle" >215</td><td align="center" valign="middle" >245</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Adjacent to outside indirectly</td><td align="center" valign="middle" >105</td><td align="center" valign="middle" >125</td><td align="center" valign="middle" >145</td><td align="center" valign="middle" >160</td></tr><tr><td align="center" valign="middle"  colspan="3"  >Sidewall of apartment building</td><td align="center" valign="middle" >120</td><td align="center" valign="middle" >140</td><td align="center" valign="middle" >160</td><td align="center" valign="middle" >175</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Floor between levels</td><td align="center" valign="middle"  colspan="2"  >Floor heating</td><td align="center" valign="middle" >30</td><td align="center" valign="middle" >35</td><td align="center" valign="middle" >45</td><td align="center" valign="middle" >50</td></tr><tr><td align="center" valign="middle"  colspan="2"  >Other</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >30</td></tr></tbody></table></table-wrap></sec><sec id="s4"><title>4. Applications of Low-Emissivity Hybrid Insulation in South Korea</title><p>Low-Emissivity Hybrid Insulation is getting to be used more and more buildings such as schools, government offices, residential buildings and commercial buildings in South Korea. It is usually applied on the reinforced concrete walls and roofs as thick as 60 - 80 mm. It is unusually used as main insulation for a building in South Korea. Recently, Low-Emissivity Insulation with fire-retarding property has been developed and used as exterior insulation for large buildings above 6 stories.</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows various building applications of Low-Emissivity Hybrid Insulation in South Korea.</p><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Insulation classification according to thermal conductivity in South Korea</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Grade</th><th align="center" valign="middle"  colspan="2"  >Thermal conductivity</th><th align="center" valign="middle" >Insulation type</th></tr></thead><tr><td align="center" valign="middle" >W/mK</td><td align="center" valign="middle" >kcal/mh∙˚C</td><td align="center" valign="middle" >Note</td></tr><tr><td align="center" valign="middle" >A</td><td align="center" valign="middle" >0.034 or lower</td><td align="center" valign="middle" >0.029 or lower</td><td align="center" valign="middle" >-XPS (Extruded Polystyrene Board) outstanding type, type 1, type 2, type 3 -EPS (Expanded Poly Styrene) class 2 (Neopor) No. 1, No. 2, No. 3, No. 4 -Rigid polyurethane foam Class 1 No. 1, No. 2, No. 3 and Class 2 No. 1, No. 2, No. 3 -Glass Wool insulating board 48 K, 64 K, 80 K, 96 K, 120 K -Thermal Conductivity is 0.034 W/mK (0.029 kcal/mh∙˚C) or lower as other insulations.</td></tr><tr><td align="center" valign="middle" >B</td><td align="center" valign="middle" >0.035 - 0.040</td><td align="center" valign="middle" >0.030 - 0.034</td><td align="center" valign="middle" >-EPS (Expanded Poly Styrene) class 1 No. 1, No. 2, No. 3 -Mineral Wool No. 1, No. 2, No. 3 -Glass Wool 24 K, 32 K, 40 K -Thermal Conductivity is 0.035 - 0.040 W/mK (0.030 - 0.034 kcal/mh∙˚C) as other insulations.</td></tr><tr><td align="center" valign="middle" >C</td><td align="center" valign="middle" >0.041 - 0.046</td><td align="center" valign="middle" >0.035 - 0.039</td><td align="center" valign="middle" >-EPS(Expandable Poly Styrene) class 1 No. 4 -Thermal Conductivity is 0.041 - 0.046 W/mK (0.035 - 0.039 kcal/mh∙˚C) as other insulations.</td></tr><tr><td align="center" valign="middle" >D</td><td align="center" valign="middle" >0.047 - 0.051</td><td align="center" valign="middle" >0.040 - 0.044</td><td align="center" valign="middle" >-Thermal Conductivity is 0.047 - 0.051 W/mK (0.040 - 0.044 kcal/mh∙˚C) as other insulations.</td></tr></tbody></table></table-wrap><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Various building applications of low-emissivity hybrid insulation in Korea</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/69354x9.png"/></fig></sec><sec id="s5"><title>Acknowledgements</title><p>This work was supported by the National Research Foundation of South Korea (NRF) and the grant funded by the South Korea government (MEST) (No. 2014R1A1A4A01005565).</p></sec><sec id="s6"><title>Cite this paper</title><p>Young Cheol Kwon, (2016) Applications of Low-Emissivity Hybrid Insulation in South Korea. Journal of Power and Energy Engineering,04,8-14. doi: 10.4236/jpee.2016.47002</p></sec></body><back><ref-list><title>References</title><ref id="scirp.69354-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Kwon, Y.C., Kim, Y.O. and Lee, G.Y. (2014) An Innovative Low-Emissivity Insulation Developed in South Korea. ASTM STP, 1574, 101-118. http://dx.doi.org/10.1520/stp157420130082</mixed-citation></ref><ref id="scirp.69354-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Kwon, Y.C. and Kim, Y.O. (2010) A Study on the Development of a High-Efficiency Low-Emissivity Insulation. Journal of KIAEBS, 4, 89-95.</mixed-citation></ref><ref id="scirp.69354-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">http://passipedia.passiv.de/ppediaen/planning/thermal_protection/external_walls/passive_house_suitable_wall_systems</mixed-citation></ref><ref id="scirp.69354-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Kwon, Y.C. (2012) Insulation Applications for Buildings in South Korea. Proceedings of 7th Global Insulation Conference, Latvia.</mixed-citation></ref><ref id="scirp.69354-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Rhee, E.K., et al. (2006) Architectural Environmental Planning. Taelim Publishing Co., 2013 ASHRAE Handbook- Fundamentals (SI), 26.20.</mixed-citation></ref><ref id="scirp.69354-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Kwon, Y.C. and Kim, K.M. (2015) A Study on the Insulating Characteristics of Low-E Insulation Depending on Heat Transfer Paths and Materials. Workshop on Architecture, South Korea. http://dx.doi.org/10.14257/astl.2015.89.15</mixed-citation></ref><ref id="scirp.69354-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Kwon, Y.C. and Kim, K.M. (2016) Insulation-Affecting Factors of Low-Emissivity Insulation. International Journal of Applied Engineering Research, 11, 838-842.</mixed-citation></ref></ref-list></back></article>