<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">Health</journal-id><journal-title-group><journal-title>Health</journal-title></journal-title-group><issn pub-type="epub">1949-4998</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/health.2016.810098</article-id><article-id pub-id-type="publisher-id">Health-68440</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  A Derived Exposure Chart for Computed Radiography in a Negroid Population
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Thomas</surname><given-names>Adejoh</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Odira</surname><given-names>C. Ewuzie</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Joshua</surname><given-names>K. Ogbonna</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Stanley</surname><given-names>O. Nwefuru</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Nnamdi</surname><given-names>C. Onuegbu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Radiology Department, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>adtoms@yahoo.com(TA)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>14</day><month>07</month><year>2016</year></pub-date><volume>08</volume><issue>10</issue><fpage>953</fpage><lpage>958</lpage><history><date date-type="received"><day>13</day>	<month>May</month>	<year>2016</year></date><date date-type="rev-recd"><day>accepted</day>	<month>12</month>	<year>July</year>	</date><date date-type="accepted"><day>15</day>	<month>July</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations.
 
</p></abstract><kwd-group><kwd>Computed Radiography</kwd><kwd> Exposure</kwd><kwd> Radiographer</kwd><kwd> kVp</kwd><kwd> Tube Current</kwd><kwd> X-Ray</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Computed Radiography (CR), scientifically known as Photostimulable Phosphor (PSP) radiography, is a digital technology for the acquisition of radiographic images [<xref ref-type="bibr" rid="scirp.68440-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.68440-ref2">2</xref>] . It is the most common digital radiography modality in radiology departments today, with an estimated 7000 systems in use worldwide. As of September 2000, there were five manufacturers of CR imaging devices: Agfa, Fuji, Kodak, Konica and Lumisys. However, their photostimulable phosphor storage plates have dissimilar dose response characteristics.</p><p>This lack of calibration uniformity makes the definition of the acceptable exposure ranges for CR cumbersome [<xref ref-type="bibr" rid="scirp.68440-ref1">1</xref>] . Even though manufacturers have responded to this challenge by offering an Exposure Index (EI), its reliability as a feedback mechanism for CR is also questionable [<xref ref-type="bibr" rid="scirp.68440-ref3">3</xref>] .</p><p>The opinion of radiologists appears to be the stop-gap measure. They react negatively to digital images with excessive noise but rarely complain about images with reduced noise [<xref ref-type="bibr" rid="scirp.68440-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.68440-ref5">5</xref>] . While increased noise is an indication of reduced dose, this is however, not desirable as it potentially reduces the visibility of subtle pathology [<xref ref-type="bibr" rid="scirp.68440-ref6">6</xref>] - [<xref ref-type="bibr" rid="scirp.68440-ref8">8</xref>] , whereas reduced noise may be an indication of overexposure and concomitantly, increased patient dose [<xref ref-type="bibr" rid="scirp.68440-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.68440-ref10">10</xref>] .</p><p>The wider exposure latitude and post-processing algorithms of digital technology mask the evidence of underexposure and overexposure [<xref ref-type="bibr" rid="scirp.68440-ref8">8</xref>] , a characteristic recognized and exploited by radiographers who eventually fall into the error of dose creep [<xref ref-type="bibr" rid="scirp.68440-ref11">11</xref>] . Dose creep is recognized as a gradual increase in X-ray exposures over time that results in increased radiation dose to the patient. This occurs where judgment to determine the correct radiographic exposure factors is needed when taking into account a large range of patient sizes [<xref ref-type="bibr" rid="scirp.68440-ref9">9</xref>] .</p><p>Since reduction in patient dose is one of the important considerations for the implementation of CR in a traditional film-based radiology department [<xref ref-type="bibr" rid="scirp.68440-ref5">5</xref>] , eliminating dose creep is very important. One effective way to do this is to develop validated radiographic technique charts for all performed examinations. These exposure charts are an essential quality assurance component of any diagnostic X-ray department. Internationally, most countries require regular use of these charts [<xref ref-type="bibr" rid="scirp.68440-ref11">11</xref>] .</p><p>The review of the literature reveals some exposure adaptation system. However, some are several decades old [<xref ref-type="bibr" rid="scirp.68440-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.68440-ref12">12</xref>] - [<xref ref-type="bibr" rid="scirp.68440-ref15">15</xref>] , and they were derived with Caucasian and Asian populations.</p><p>A simple CR-specific chart derived using negroid populations from and in Africa, and which covers the most common examinations, is what this work was designed to address. This chart is specific to AGFA photostimulable phosphor plates and GE static X-ray machines manufactured not earlier than 2003. Centers with comparable machine age and ratings as well as similar photostimulable phosphor plates will find the results useful in dose optimization and quality control.</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>The work is a mixed design incorporating both prospective and retrospective components. It was carried out between June to September, 2015 at a teaching hospital in Nigeria. Confidentiality was maintained by omitting names, ward, address and clinical indications of the subjects during data collection.</p><p>The X-ray machine used was a GE silhouette VR, high frequency, 3-phase, static digital unit with a maximum tube potential and current of 140 kVp and 600 mA respectively, and a total filtration of 2.7 mmAl. It was manufactured in 2003 and installed in 2011 by VAMED. A potter-bucky couch and erect chest stand were used. Other equipment and accessories were a CR-12-x digitizer and new 17 &#215; 14 inch photostimulable phosphor imaging plates (model CRMD1.0) manufactured by Agfa Healthcare, Belgium, and installed at the teaching hospital in October, 2014.</p><p>Any patient who came for X-ray examination within the study period and could stand erect formed part of the population. Their age and gender were obtained from their request cards. Chest examinations were done at a focus-film-distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD.</p><p>Although the researchers are staff of the centre in focus, the work was blinded to all other staff to minimize bias. Because of the wide exposure latitude and post-processing features of the computed radiography modality, it was observed that the radiographers in the centre did not have specific exposure parameters for different body habitus. The subjects were therefore, not categorized in accordance with body size but considered as a homogenous group.</p><p>The range of exposure factors (kVp, mA and mAs) used by other radiographers in the centre were noted by the researchers. Subsequently, the 90<sup>th</sup> percentile of the factors was calculated. Over a three-month period, the patients were examined with the 90<sup>th</sup> percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers unconnected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA).</p><p>Descriptive statistics from the statistical packages for social sciences, version 17.0 (SPSS Incorporated, Chicago, Illinois, USA) was used to analyze the data.</p></sec><sec id="s3"><title>3. Results</title><p>335 subjects of both gender aged 0 - 92 years were examined by the researchers (<xref ref-type="table" rid="table1">Table 1</xref>). Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers- derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively (<xref ref-type="table" rid="table2">Table 2</xref>). A comparison of this work with another one gave comparable results except in chest where their kVp (106) and mAs (3.33) was significantly higher than ours (73 kVp, 10 mAs) as shown in <xref ref-type="table" rid="table3">Table 3</xref>. Statistical analyses using one-sample t-test for both mAs (3.33; 10) and kVp (106; 73) with p &lt; 0.05 as level of significance gave a statistically significant difference between the mAs (p = 0.002) and kVp (p = 0.000) respectively. Further correlation to determine the level of clinical significance yielded r = 0.675 (mAs) and r = 0.236 (kVp) respectively. These indicate that the difference in mAs is clinically significant while that in kVp is not clinically significant (<xref ref-type="table" rid="table4">Table 4</xref>).</p></sec><sec id="s4"><title>4. Discussion</title><p>Digital technology has wider exposure latitude and post-processing algorithms which can mask the evidence of underexposure and overexposure. These characteristics have serious impact on diagnosis and patient radiation dose respectively [<xref ref-type="bibr" rid="scirp.68440-ref8">8</xref>] . Understanding what constitutes under-exposure and over-exposure is however, cumbersome [<xref ref-type="bibr" rid="scirp.68440-ref1">1</xref>] , because computed radiography modality has the capability to normalize various degrees of exposure adjustment and produce a standard optical density irrespective of errors [<xref ref-type="bibr" rid="scirp.68440-ref8">8</xref>] . This work was an attempt to define over-exposure by revealing the minimum exposure parameters that can yield images of acceptable diagnostic quality.</p><p>Our findings show that no matter the temptation to err on the side of dose creep, a much lower kVp, mA and mAs can give acceptable results (Figures i-viii). The densest anatomy can be conveniently examined with a maximum of 250 mA and &lt;94 kVp (<xref ref-type="table" rid="table2">Table 2</xref>). This disagrees however, with the finding of a similar work where the researchers compared film/screen technology, CR and direct digital radiography, and found that CR needs a higher exposure to the patient to provide equivalent image quality to film/screen [<xref ref-type="bibr" rid="scirp.68440-ref16">16</xref>] . This is likely if optical</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Throughput of adult subjects examined during the study period</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Parameter</th><th align="center" valign="middle" >Male</th><th align="center" valign="middle" >Female</th><th align="center" valign="middle" >Total</th><th align="center" valign="middle" >%</th></tr></thead><tr><td align="center" valign="middle" >Chest</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >103</td><td align="center" valign="middle" >183</td><td align="center" valign="middle" >55</td></tr><tr><td align="center" valign="middle" >Lumbo-sacral spine</td><td align="center" valign="middle" >18</td><td align="center" valign="middle" >22</td><td align="center" valign="middle" >40</td><td align="center" valign="middle" >12</td></tr><tr><td align="center" valign="middle" >Skull</td><td align="center" valign="middle" >14</td><td align="center" valign="middle" >18</td><td align="center" valign="middle" >32</td><td align="center" valign="middle" >9.6</td></tr><tr><td align="center" valign="middle" >Knee</td><td align="center" valign="middle" >11</td><td align="center" valign="middle" >13</td><td align="center" valign="middle" >24</td><td align="center" valign="middle" >7.2</td></tr><tr><td align="center" valign="middle" >Femur</td><td align="center" valign="middle" >9</td><td align="center" valign="middle" >12</td><td align="center" valign="middle" >19</td><td align="center" valign="middle" >5.7</td></tr><tr><td align="center" valign="middle" >Cervical spine</td><td align="center" valign="middle" >6</td><td align="center" valign="middle" >13</td><td align="center" valign="middle" >19</td><td align="center" valign="middle" >5.7</td></tr><tr><td align="center" valign="middle" >Pelvis/hip</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >9</td><td align="center" valign="middle" >16</td><td align="center" valign="middle" >4.8</td></tr><tr><td align="center" valign="middle" >Total (%)</td><td align="center" valign="middle" >145 (43.3%)</td><td align="center" valign="middle" >190 (56.7%)</td><td align="center" valign="middle" >335</td><td align="center" valign="middle" >100</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Derived exposure chart</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Variable</th><th align="center" valign="middle"  rowspan="2"  >Age (years)</th><th align="center" valign="middle"  rowspan="2"  >FFD (cm)</th><th align="center" valign="middle"  colspan="2"  >kVp</th><th align="center" valign="middle"  colspan="2"  >mAs</th><th align="center" valign="middle"  colspan="2"  >mA</th></tr></thead><tr><td align="center" valign="middle" >Range</td><td align="center" valign="middle" >Derived</td><td align="center" valign="middle" >Range</td><td align="center" valign="middle" >Derived</td><td align="center" valign="middle" >Range</td><td align="center" valign="middle" >Derived</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Chest (PA)</td><td align="center" valign="middle" >0 - 3</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >50 - 60</td><td align="center" valign="middle" >52</td><td align="center" valign="middle" >3.20 - 6.25</td><td align="center" valign="middle" >3.20</td><td align="center" valign="middle" >50 - 125</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >4 - 9</td><td align="center" valign="middle" >150</td><td align="center" valign="middle" >50 - 65</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >3.20 - 6.25</td><td align="center" valign="middle" >4.5</td><td align="center" valign="middle" >50 - 160</td><td align="center" valign="middle" >140</td></tr><tr><td align="center" valign="middle" >10 - 17</td><td align="center" valign="middle" >150</td><td align="center" valign="middle" >50 - 75</td><td align="center" valign="middle" >65</td><td align="center" valign="middle" >4.0 - 10.0</td><td align="center" valign="middle" >6.5</td><td align="center" valign="middle" >80 - 250</td><td align="center" valign="middle" >220</td></tr><tr><td align="center" valign="middle" >21 - 89</td><td align="center" valign="middle" >150 - 180</td><td align="center" valign="middle" >68 - 82</td><td align="center" valign="middle" >73</td><td align="center" valign="middle" >5.25 - 12.60</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >160 - 250</td><td align="center" valign="middle" >230</td></tr><tr><td align="center" valign="middle" >Lumbo-sacral</td><td align="center" valign="middle" >33 - 92</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >78 - 130</td><td align="center" valign="middle" >94</td><td align="center" valign="middle" >8.0 - 25.0</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >100 - 320</td><td align="center" valign="middle" >250</td></tr><tr><td align="center" valign="middle" >Pelvis</td><td align="center" valign="middle" >18 - 88</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >70 - 85</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >8.0 - 16.0</td><td align="center" valign="middle" >12.8</td><td align="center" valign="middle" >80 - 250</td><td align="center" valign="middle" >220</td></tr><tr><td align="center" valign="middle" >Knee</td><td align="center" valign="middle" >21 - 86</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >45 - 70</td><td align="center" valign="middle" >62</td><td align="center" valign="middle" >4.0 - 6.30</td><td align="center" valign="middle" >5.0</td><td align="center" valign="middle" >63 - 125</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >Femur</td><td align="center" valign="middle" >24 - 90</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >60 - 85</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >6.3 - 20.0</td><td align="center" valign="middle" >10.0</td><td align="center" valign="middle" >100 - 250</td><td align="center" valign="middle" >200</td></tr><tr><td align="center" valign="middle" >Cervical/S (AP)</td><td align="center" valign="middle" >32 - 87</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >63 - 88</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >4.0 - 12.5</td><td align="center" valign="middle" >6.4</td><td align="center" valign="middle" >50 - 150</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >Skull (OF/Lat)</td><td align="center" valign="middle" >18 - 91</td><td align="center" valign="middle" >90 - 100</td><td align="center" valign="middle" >74 - 80</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >8.0 - 10.0</td><td align="center" valign="middle" >8.5</td><td align="center" valign="middle" >160 - 200</td><td align="center" valign="middle" >180</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Comparison of different works</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Parameter</th><th align="center" valign="middle"  colspan="3"  >Williams et al., 2007 (mobile unit)</th><th align="center" valign="middle"  colspan="3"  >Williams et al., 2007 (static unit)</th><th align="center" valign="middle"  colspan="3"  >Present study, 2015 (static unit)</th></tr></thead><tr><td align="center" valign="middle" >kVp</td><td align="center" valign="middle" >mAs</td><td align="center" valign="middle" >mA</td><td align="center" valign="middle" >kVp</td><td align="center" valign="middle" >mAs</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >kVp</td><td align="center" valign="middle" >mAs</td><td align="center" valign="middle" >mA</td></tr><tr><td align="center" valign="middle" >Chest (PA)</td><td align="center" valign="middle" >85</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >106</td><td align="center" valign="middle" >3.33</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >73</td><td align="center" valign="middle" >10.0</td><td align="center" valign="middle" >230</td></tr><tr><td align="center" valign="middle" >Femur (AP/Lat)</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >76</td><td align="center" valign="middle" >16</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >10.0</td><td align="center" valign="middle" >200</td></tr><tr><td align="center" valign="middle" >Pelvis (AP)</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >24</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >12.8</td><td align="center" valign="middle" >220</td></tr><tr><td align="center" valign="middle" >Cervical/S (AP)</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >7.5</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >76</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >6.4</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >Cervical/S (Lat)</td><td align="center" valign="middle" >65</td><td align="center" valign="middle" >15</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >76</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >6.4</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >Knee (AP)</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >6.67</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >62</td><td align="center" valign="middle" >5</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >Knee (Lat)</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >16</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >6.67</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >5</td><td align="center" valign="middle" >63</td></tr><tr><td align="center" valign="middle" >Lumbosacral/S (AP)</td><td align="center" valign="middle" >75</td><td align="center" valign="middle" >48</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >94</td><td align="center" valign="middle" >20.0</td><td align="center" valign="middle" >250</td></tr><tr><td align="center" valign="middle" >Lumbosacral/S (Lat)</td><td align="center" valign="middle" >85</td><td align="center" valign="middle" >150</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >94</td><td align="center" valign="middle" >20.0</td><td align="center" valign="middle" >250</td></tr><tr><td align="center" valign="middle" >Skull (AP)</td><td align="center" valign="middle" >60</td><td align="center" valign="middle" >16</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >80</td><td align="center" valign="middle" >13.33</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >8.5</td><td align="center" valign="middle" >180</td></tr><tr><td align="center" valign="middle" >Skull (Lat)</td><td align="center" valign="middle" >55</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >76</td><td align="center" valign="middle" >6.67</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >70</td><td align="center" valign="middle" >8.5</td><td align="center" valign="middle" >180</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Statistical comparison of the present study with a similar work for chest parameters</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >Williams et al., 2007</th><th align="center" valign="middle" >Present study, 2015</th><th align="center" valign="middle" >One-sample t-test</th><th align="center" valign="middle" >Remark</th><th align="center" valign="middle" >Pearson’s correlation</th><th align="center" valign="middle" >Remark</th></tr></thead><tr><td align="center" valign="middle" >kVp</td><td align="center" valign="middle" >106</td><td align="center" valign="middle" >73</td><td align="center" valign="middle" >p = 0.000</td><td align="center" valign="middle" >Statistically significant</td><td align="center" valign="middle" >r = 0.236</td><td align="center" valign="middle" >Not clinically significant</td></tr><tr><td align="center" valign="middle" >mAs</td><td align="center" valign="middle" >3.33</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >p = 0.002</td><td align="center" valign="middle" >Statistically significant</td><td align="center" valign="middle" >r = 0.675</td><td align="center" valign="middle" >Clinically significant</td></tr></tbody></table></table-wrap><p>p &lt; 0.05 (level of significance).</p><p>density is the primary interest but our work shows that a comparably higher exposure may not be necessary to produce diagnostically useful images.</p><p>It has however, been shown that increasing the tube potential in chest radiography from 60 kVp to 90 kVp will result in a decrease in entrance surface dose (ESD) by 60% and effective dose by 20%. Therefore, the use of low tube potentials for dense anatomy is discouraged [<xref ref-type="bibr" rid="scirp.68440-ref17">17</xref>] . Even though an image that is diagnostically useful can still be produced at a lower kVp, the researchers were mindful of the consideration for entrance surface dose to start their decrease in exposure factors from the 90<sup>th</sup> percentile and eventually arrived at a tube potential of 70 kVp (skull), 73 kVp (chest), 75 kVp (femur), 75 kVp (pelvis) and 94 kVp (lumbosacral) respectively (<xref ref-type="table" rid="table3">Table 3</xref>). Previous researchers however, pegged the optimum tube potential for adult chest radiography at 60 kVp [<xref ref-type="bibr" rid="scirp.68440-ref18">18</xref>] , and 106 kVp [<xref ref-type="bibr" rid="scirp.68440-ref11">11</xref>] . The wide variation between the three works is possibly an indication of differences in subjects, training and inter-radiographer idiosyncracies.</p></sec><sec id="s5"><title>5. Conclusion</title><p>Dose creep can be minimized by a computed radiography-specific exposure chart. Such a chart has been derived for a negroid population in Nigeria using AGFA photostimulable phosphor plates and a GE static X-ray machine manufactured not earlier than 2003. In addition, the upper threshold of adult exposure factors using comparable equipment and accessories is 94 kVp, 250 mA and 20.0 mAs respectively. The radiographer, rather than technology, is the major determinant of patient dose in view of their ability to manipulate exposure parameters.</p></sec><sec id="s6"><title>Limitation</title><p>A comparison of our exposure chart with that of other hospitals in the locality would have given an idea into the extent of variations using comparable as well as different equipment and accessories. Unfortunately, there are no documented charts in the literature from our locality.</p></sec><sec id="s7"><title>Recommendations</title><p>Similar works that will replicate ours should be carried out using different PSP plates than the AGFA used by us to determine the extent of variation between different receptors. In addition, the entrance skin dose level of the recommended exposure factors should be investigated to ascertain if they are within acceptable limits.</p></sec><sec id="s8"><title>Declarations</title><p>Conflict of interest and funding: nil.</p></sec><sec id="s9"><title>Cite this paper</title><p>Thomas Adejoh,Odira C. Ewuzie,Joshua K. Ogbonna,Stanley O. Nwefuru,Nnamdi C. Onuegbu, (2016) A Derived Exposure Chart for Computed Radiography in a Negroid Population. Health,08,953-958. doi: 10.4236/health.2016.810098</p></sec><sec id="s10"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.68440-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Samei, E., Seibert, J.A., Willis, C.E., Flynn, M.J., Mah, E. and Junck, K.L. (2001) Performance Evaluation of Computed Radiography Systems. Medical Physics, 28, 361-371.  
http://dx.doi.org/10.1118/1.1350586</mixed-citation></ref><ref id="scirp.68440-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Sonoda, M., Takano, M., Miyahara, J. and Kato, H. (1983) Computed Radiography Utilizing Scanning Laser Stimulated Luminescence. Radiology, 148, 833-838.  
http://dx.doi.org/10.1148/radiology.148.3.6878707</mixed-citation></ref><ref id="scirp.68440-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Butler, M.L., Rainford, L., Last, J. and Brennan, P.C. (2010) Are Exposure Index Values Consistent in Clinical Practice? A Multi-Manufacturer Investigation. Radiation Protection Dosimetry, 139, 371-374.  
http://dx.doi.org/10.1093/rpd/ncq094</mixed-citation></ref><ref id="scirp.68440-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Seibert, J.A., Shelton, D.K. and Moore, E.H. (1996) Computed Radiography X-Ray Exposure Trends. Academic Radiology, 3, 313-318.  
http://dx.doi.org/10.1016/S1076-6332(96)80247-9</mixed-citation></ref><ref id="scirp.68440-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Freedman, E.P., Mun, S.K., La, S.C.B. and Nelson, M. (1993) The Potential for Unnecessary Patient Exposure from the Use of Storage Phosphor Imaging Systems. SPIE Medical Imaging, 1897, 472-479.  
http://dx.doi.org/10.1117/12.146998</mixed-citation></ref><ref id="scirp.68440-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Thakur, Y., Bjarnason, T.A., Hammerstrom, K., Marchinkow, L., Koch, T. and Aldrich, J.E. (2012) Assessment of Patient Doses in CR Examinations throughout a Large Health Region. Journal of Digital Imaging, 25, 189-195. 
http://dx.doi.org/10.1007/s10278-011-9390-1</mixed-citation></ref><ref id="scirp.68440-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Heath, R., England, A., Ward, A., et al. (2011) Digital Pelvic Radiography: Increasing Distance to Reduce Dose. Radiologic Technology, 83, 20-28.</mixed-citation></ref><ref id="scirp.68440-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Ching, W., Robinson, J. and McEntee, M.F. (2015) DigiBit: A System for Adjusting Radiographic Exposure Factors in the Digital Era. Radiologic Technology, 86, 614-622.</mixed-citation></ref><ref id="scirp.68440-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Gibson, D.J. and Davidson, R.A. (2012) Exposure Creep in Computed Radiography: A Longitudinal Study. Academic Radiology, 19, 458-462.  
http://dx.doi.org/10.1016/j.acra.2011.12.003</mixed-citation></ref><ref id="scirp.68440-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Herrmann, T.L., Fauber, T.L., Gill, J., et al. (2012) Best Practices in Digital Radiography. Radiologic Technology, 84, 83-89.</mixed-citation></ref><ref id="scirp.68440-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Williams, M.B., Krupinski, E.A., Strauss, K.J., Breeden, W.K., Rzeszotarski, M.S., Applegate, K., Wyatt, M., Bjork, S. and Seibert, J.A. (2007) Digital Radiography Image Quality: Image Acquisition. Journal of the American College of Radiology, 4, 371-388.  
http://dx.doi.org/10.1016/j.jacr.2007.02.002</mixed-citation></ref><ref id="scirp.68440-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Fauber, T.L., Cohen, T.F. and Dempsey, M.C. (2011) High Kilovoltage Digital Exposure Techniques and Patient Dosimetry. Radiologic Technology, 82, 501-510.</mixed-citation></ref><ref id="scirp.68440-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Simon, M. (1956) Exposure Factor Selection by Means of a New Calculator. British Journal of Radiology, 29, 588- 595.  
http://dx.doi.org/10.1259/0007-1285-29-347-588</mixed-citation></ref><ref id="scirp.68440-ref14"><label>14</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Gyss</surname><given-names> E.E. </given-names></name>,<etal>et al</etal>. (<year>1957</year>)<article-title>A Medical Radiographic Technique Chart Based on Constants</article-title><source> X-Ray Technician</source><volume> 29</volume>,<fpage> 76</fpage>-<lpage>80</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.68440-ref15"><label>15</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Power</surname><given-names> K.J. </given-names></name>,<etal>et al</etal>. (<year>1959</year>)<article-title>A Simple Measuring Device for the Busy Department</article-title><source> Radiographer</source><volume> 7</volume>,<fpage> 16</fpage>-<lpage>17</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.68440-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Compagnone, G., Baleni, M.C., Pagan, L., Calzolaio, F., Barozzi, L. and Bergamini, C. (2006) Comparison of Radiation Doses to Patients Undergoing Standard Radiographic Examinations with Conventional Screen-Film Radiography, Computed Radiography and Direct Digital Radiography. British Journal of Radiology, 79, 899-904. 
http://dx.doi.org/10.1259/bjr/57138583</mixed-citation></ref><ref id="scirp.68440-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Martin, C.J., Darragh, C.L., McKenzie ,G.A. and Bayliss, A.P. (1993) Implementation of a Programme for Reduction of Radiographic Doses and Results through Increase in Tube Potential. British Journal of Radiology, 66, 228-233. 
http://dx.doi.org/10.1259/0007-1285-66-783-228</mixed-citation></ref><ref id="scirp.68440-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Ma, W.K., Hogg, P., Tootell, A., Manning, D., Thomas, N., Kane, T. and Kelly, J. (2013) Anthropomorphic Chest Phantom Imaging: The Potential for Dose Creep in Computed Radiography. Radiography, 19, 207-211. 
http://dx.doi.org/10.1016/j.radi.2013.04.002</mixed-citation></ref></ref-list></back></article>