<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ABB</journal-id><journal-title-group><journal-title>Advances in Bioscience and Biotechnology</journal-title></journal-title-group><issn pub-type="epub">2156-8456</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/abb.2016.76026</article-id><article-id pub-id-type="publisher-id">ABB-67801</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject></subj-group></article-categories><title-group><article-title>
 
 
  Analysis of Nitrogen Dioxide in Environment
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jun</surname><given-names>Wang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Wei</surname><given-names>Zhang</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Rui</surname><given-names>Cao</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xiangyu</surname><given-names>You</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hong</surname><given-names>Lai</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff4"><addr-line>Department of Radiology, Johns Hopkins School of Medicine, Baltimore, Maryland, USA</addr-line></aff><aff id="aff2"><addr-line>C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA</addr-line></aff><aff id="aff3"><addr-line>Department of Chemistry, Johns Hopkins University, Baltimore, Maryland, USA</addr-line></aff><aff id="aff1"><addr-line>Department of Pharmacy, Food and Pharmaceutical Engineering College, Hubei University of Technology, Wuhan, Hubei, China</addr-line></aff><pub-date pub-type="epub"><day>23</day><month>06</month><year>2016</year></pub-date><volume>07</volume><issue>06</issue><fpage>278</fpage><lpage>288</lpage><history><date date-type="received"><day>14</day>	<month>May</month>	<year>2016</year></date><date date-type="rev-recd"><day>accepted</day>	<month>26</month>	<year>June</year>	</date><date date-type="accepted"><day>29</day>	<month>June</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  As a severe environmental pollutant, detection and quantitation of nitrogen dioxide (NO
  <sub>2</sub>) have been studied for centuries. In this review, recent progress of NO
  <sub>2</sub> analysis in the atmosphere will be summarized. Four major types of detection technologies, including traditional chemical detection, optical detection, solid-state field effect transistor detection, and other detection technology are covered. The standard method employed by the US EPA, which is based on luminol, is the most reliable and robust method that is used for fully validated monitoring. In the past two decades, accompanying the fast development of electrical engineering and integrated circuit, micro to nanoscale gas sensors have been gaining more and more attention. Application of novel materials including nano wires and graphene also leads to a new era of research and development of sensors.
 
</p></abstract><kwd-group><kwd>Nitrogen Dioxide</kwd><kwd> Chemical Detection</kwd><kwd> Optical Detection</kwd><kwd> Field-Effect Transistor Detection</kwd><kwd> Luminol</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><sec id="s1_1"><title>1.1. Background and Scope</title><p>Nitrogen dioxide (NO<sub>2</sub>) is one of the major environmental pollutants, which belongs to the family of nitrogen oxides (NO<sub>x</sub>). The major source of NO<sub>2</sub> in the air comes from combustion of fossil fuels [<xref ref-type="bibr" rid="scirp.67801-ref1">1</xref>] . NO<sub>2</sub> gas forms when fuel is burned at high temperatures, primarily from the exhaust of motor vehicles and power plants. NO<sub>2</sub> is a strong oxidizing agent that may form highly toxic nitric acid and organic nitrate. Furthermore, NO<sub>2</sub> leads to the production of ground level ozone, which is also recognized as smog [<xref ref-type="bibr" rid="scirp.67801-ref2">2</xref>] . Studies have shown that NO<sub>2</sub> and related derivatives (NO<sub>x</sub>) will increase the risk of lung cancer [<xref ref-type="bibr" rid="scirp.67801-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref4">4</xref>] . The International Agency for Research on Cancer recently classified outdoor air pollution and particulate matter as carcinogenic (Group 1) [<xref ref-type="bibr" rid="scirp.67801-ref5">5</xref>] . In the United States, EPA (Environmental Protection Agency) has set primary standards in compliant of the Clean Air Act of NO<sub>2</sub> to not exceed 53 ppb as annual mean (<xref ref-type="fig" rid="fig1">Figure 1</xref>) [<xref ref-type="bibr" rid="scirp.67801-ref6">6</xref>] . Therefore, fast, sensitive and reliable analysis of NO<sub>2</sub> is an essential need for the public health, as well as for personal protection. In this review, we will summarize some of the key techniques reported to detect and quantitate NO<sub>2</sub> in the past two decades, and give advice for further research.</p></sec><sec id="s1_2"><title>1.2. Types of Technology Used for NO<sub>2</sub> Analysis</title><p>Widely used NO<sub>2</sub> analysis technologies can be divided into the following four categories based on the mechanism of detection: traditional chemical analysis, optical detection, field-effect transistor detection and other detection techniques.</p><sec id="s1_2_1"><title>1.2.1. Traditional Chemical Analysis</title><p>Analysis of NO<sub>2</sub> and related substances such as NH<sub>3</sub> and other nitrogen containing compounds can be dated to more than one hundred years ago [<xref ref-type="bibr" rid="scirp.67801-ref8">8</xref>] . These methods are often based on the chemical reactions of NO<sub>2</sub> and/or other forms of nitrogen. NO<sub>2</sub> are required to be converted to NH<sub>3</sub> in certain detecting methods [<xref ref-type="bibr" rid="scirp.67801-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref9">9</xref>] . Acid-base titration and reduction-oxidation titration was often used to determine the content of nitrogen species [<xref ref-type="bibr" rid="scirp.67801-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref9">9</xref>] . Automated machineries were created to simplify this titration process and to enable the continuous analysis of large batches of samples [<xref ref-type="bibr" rid="scirp.67801-ref9">9</xref>] . However, the required sample size was large. Up to the order of several grams of sample was required for each analysis. Therefore, sensitivity was low as the limit of detection is 0.1% of the sample weight. Selectivity was also limited due to other interferences that also carry the same property [<xref ref-type="bibr" rid="scirp.67801-ref9">9</xref>] .</p></sec><sec id="s1_2_2"><title>1.2.2. Optical Detection</title><p>Luminol is achemical reagent that emits chemiluminescence in the presence of appropriate oxidizing agent and metal catalysts. NO<sub>2</sub> is a strong oxidizer, which can readily trigger the chemiluminescence reaction of luminol. With the help of photon multiplier tube (PMT), detection of NO<sub>2</sub> with luminal is very sensitive. Further</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Mean NO<sub>2</sub> level monitored across the US 1980-2014 [<xref ref-type="bibr" rid="scirp.67801-ref7">7</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7301211x7.png"/></fig><p>developments of the chemiluminescence detection include utilizing luminol in a solid substrate support to simplify the design. It has become the standard analytical technique of NO<sub>2</sub> in the quality evaluation of air. Cavity attenuated phase shift (CAPS) spectroscopy takes advantage of the phase shift caused by light signal in the presence of NO<sub>2</sub> in an optical resonant cavity. Most interference can be filtered out by the highly selective and specific absorption of NO<sub>2</sub>, without compromising the high sensitivity achieved by PMT.</p></sec><sec id="s1_2_3"><title>1.2.3. Field-Effect Transistor Detection</title><p>Absorption of NO<sub>2</sub> or other gases may lead to changes of the chemical composition of a thin film of sensitive material. Electro-chemical behaviors including impedance, conductivity and resistivity will be changed accordingly. Therefore, detection and analysis of electrical signals can be used to calculate NO<sub>2</sub> concentrations. With the help of signal detection and amplification by the rapidly developing field-effect transistor (FET) and integrated circuit (IC), many gas sensors were created and investigated [<xref ref-type="bibr" rid="scirp.67801-ref10">10</xref>] . These sensors can be made solid-state, versatile to use and economic to manufacture with fast response and small scale,</p></sec><sec id="s1_2_4"><title>1.2.4. Other Detection Techniques</title><p>There are some other detection technologies for NO<sub>2</sub> detection and quantitation. NO<sub>2</sub> may lead to unique changes of physical or chemical properties of these materials that absorb NO<sub>2</sub>. One example is the change of frequencies of a piezoelectric crystal [<xref ref-type="bibr" rid="scirp.67801-ref11">11</xref>] . Another method is widely used in biological samples. NO<sub>2</sub> reacts with tyrosyl radical to form nitrotyrosine, which is a biomarker of oxidative stress in patients with cardiovascular and neurodegenerative diseases. Immunoassay of this biomarker is capable to detect trace amount of NO<sub>2</sub> reacting with myoglobin [<xref ref-type="bibr" rid="scirp.67801-ref12">12</xref>] .</p></sec></sec></sec><sec id="s2"><title>2. Review of Technologies</title><sec id="s2_1"><title>2.1. Traditional Chemical Analysis</title><p>Analysis of nitrogen content in organic samples started in the late 19<sup>th</sup> century. Kjeldahl [<xref ref-type="bibr" rid="scirp.67801-ref8">8</xref>] published the work on digesting organic matters with sulfuric and phosphoric acids in 1888. The nitrogen content was converted to ammonium sulfate and then to ammonia, which was distilled into a measured volume of standard acid. Further analysis by acid-base titration of ammonia completed this indirect analysis of any form of nitrogen contents in the sample. Many researchers have worked on optimization of the classic Kjeldahl method to improve its digestion efficiency, while the essence of chemistry behind this method stays the same. This method has its own drawbacks on speed, accuracy, and most importantly, specificity. Almost all forms of nitrogen, including NO<sub>2</sub>, NH<sub>3</sub>, and other organic nitrogen, are analyzed as combined together.</p><p>Andres Ferrari proposed a system for continuous digestion and analysis based on the Kjeldahl method [<xref ref-type="bibr" rid="scirp.67801-ref9">9</xref>] . Automation of sample handling was performed with a grooved quartz tube, which was rotated by motor-driven wheels and allowed the sample solution to flow from one end of the tube to the other. The tube was heated inside a tube furnace to 400˚C - 600˚C. The high temperature and presence of oxidants converted nitrogen content into ammonium salts. The salts were then treated with excess of base. Afterwards, the liberated ammonia was collected in measured volume of standard acid. The residual acid was titrated with standard base, which quantified the total nitrogen content [<xref ref-type="bibr" rid="scirp.67801-ref9">9</xref>] .</p><p>This automated method has produced similar results as the classic manual method with significantly reduced workload requirement. The rate of analysis using this automated system is up to 10 samples per hour. However, the classic methods are only capable of determining nitrogen content in single digit percentage. Limit of detection of both manual and automatic titration is about 0.1% of the sample weight.</p></sec><sec id="s2_2"><title>2.2. Optical Detection</title><p>Chemiluminescence was the most prevalent and dominating method for the analysis of NO<sub>2</sub> in the air. The United States Environmental Protection Agency (EPA) has published the official guidance of the standard chemiluminescence method for NO<sub>2</sub> analysis [<xref ref-type="bibr" rid="scirp.67801-ref10">10</xref>] . This technique was first discussed in detail by Fontijn et al. in 1964 [<xref ref-type="bibr" rid="scirp.67801-ref13">13</xref>] . Since then, it has been intensively studied since then. The resulted reliable, simple and accurate method was then recommended by EPA and other regulatory agencies around the world as the first choice for routine NO<sub>2</sub> analysis.</p><p>The standard method regulated by EPA employs the creation of chemiluminescence using ozone. In this reaction, NO<sub>2</sub> is first reduced to nitric oxide (NO). Then NO reacts with O<sub>3</sub> to form the exited state of nitrogen dioxide, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-7301211x8.png" xlink:type="simple"/></inline-formula>, which emits light while returning back to the ground state of NO<sub>2</sub>.</p><disp-formula id="scirp.67801-formula1398"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-7301211x9.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.67801-formula1399"><label>. (2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-7301211x10.png"  xlink:type="simple"/></disp-formula><p>Intensity of light is proportional to the concentration of NO<sub>2</sub>. Commercially available instruments deliver a fully validated analysis and conform to EPA specifications. The dynamic range used for daily NO<sub>2</sub> monitoring is from 0 to 500 ppb. Traceable NO or NO<sub>2</sub> standards are also readily available for the calibration of the instruments. Instrument using the luminol method is currently the first and only method available in pursue of the regulated environmental monitoring of NO<sub>2</sub> in air. NO and other nitrogen oxides are common interferences for this method. In addition, free radicals in the air may also reduce the amount of exited NO<sub>2</sub>, leading to a lower result.</p><p>Wendel described a continuous NO<sub>2</sub> monitoring system capable of detecting NO<sub>2</sub> in the sub ppb range [<xref ref-type="bibr" rid="scirp.67801-ref14">14</xref>] . This instrument employed several pumps to circulate air and the reagent solutions. PMT was used to detect the emitting light. Due to very high amplification gains of PMT, the detection limit is down to 30 pptr. Interference of O<sub>3</sub> was avoided using gas washing prior to entering the reaction chamber. However, there were still interferences including other nitrogen oxides (NO<sub>x</sub>). An alternative method is recommended for extreme cases in cluding field study, instead of using chemiluminescence. Collins et al. [<xref ref-type="bibr" rid="scirp.67801-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref16">16</xref>] introduced an improved Luminol-based NO<sub>2</sub> analysis (<xref ref-type="fig" rid="fig2">Figure 2</xref>). The solution circulation system was replaced by a thin film of hydrogel, which immobilized luminol with necessary catalysts.</p><p>Besides chemiluminescence, Cavity Attenuated Phase Shift Spectroscopy (CAPS) developed by Aerodyne Inc. was also used for NO<sub>2</sub> analysis (<xref ref-type="fig" rid="fig3">Figure 3</xref>) [<xref ref-type="bibr" rid="scirp.67801-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref22">22</xref>] . CAPS is related to cavity ring-down spectroscopy (CRDS). In CAPS and CRDS, the measurements of light absorption are made possible by using an extremely long effective path length. A beam of laser is introduced into a cavity with two highly reflective mirrors. The light can “bounce” back and forth with path length over one kilometer. The resulting signal measured at the exit mirror will show exponential decay over time (Ring-down). The decay time is related to the concentration of the</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Basic chemiluminescence reactions between luminol and NO<sub>2</sub> [<xref ref-type="bibr" rid="scirp.67801-ref16">16</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7301211x11.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Calibration of CAPS NO<sub>2</sub> sensor [<xref ref-type="bibr" rid="scirp.67801-ref22">22</xref>] (re-printed with permission)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7301211x12.png"/></fig><p>light-absorbing species in the cavity [<xref ref-type="bibr" rid="scirp.67801-ref23">23</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref24">24</xref>] .</p><p>The main oscillation chamber used in CAPS was constructed using two highly reflective mirrors facing each other, similar to CRDS. A beam of modulated broadband light created by LED is directed into the chamber. Presence of NO<sub>2</sub> causes a phase shift in the signal output, which is proportional to the concentration of NO<sub>2</sub>. 430 nm was chosen as the light wavelength because it matches the maximum absorption of NO<sub>2</sub>. With the use of an interference filter, the limit of detection is 0.5 ppb. This sensor is capable of measuring 0 - 200 ppb of NO<sub>2</sub> in the air. However, the noticeable curvature seen in the calibration towards 200 ppb is caused by loss of light during absorption, which is comparable to the phase shift effect at higher concentrations [<xref ref-type="bibr" rid="scirp.67801-ref22">22</xref>] . <xref ref-type="table" rid="table1">Table 1</xref> summarized chemiluminescence and non-chemiluminescence techniques used in optical NO<sub>2</sub> detection.</p></sec><sec id="s2_3"><title>2.3. Field Effect Transistor Detection</title><p>Though chemical and optical analysis techniques are good options for NO<sub>2</sub> analysis, researchers are continuously seeking for new sensors that are in solid state, easy to operate, maintenance-free and small in size. Without the requirement of any chemical solutions, gas sensors have been made perfect candidates for varies of applications both in the lab and the field. Its simplicity also enables the mass production with relatively low cost for each unit. Integration with modern electrical engineering allows direct control and digital signal transmission to a data collection device. Interest for the FET gas sensors is increasing, accompanying hundreds of research articles and communication papers in this field. The study of sensor design and material has been divided into two ways. One is the optimization of the sensing performance. The other is the additional feature and utilizations on top of the good performance.</p><p>Early work on FET gas sensors can be tracked back to 1980s. In a study by Kolesar et al. [<xref ref-type="bibr" rid="scirp.67801-ref25">25</xref>] in 1989, IGE- FET was coupled to a thin film of copper phthalocyanine (CuPc), which selectively reacted with IGE-FET at ppb levels. Measurement was based on the sensitivity of the field effect transistor’s output current to changes in the molecular structure or chemical composition of the thin film which covers the interdigitated gate electrode.</p><p>A versatile sensor platform of NO<sub>2</sub> in the air was developed by Oprea et al. in 2007 (<xref ref-type="fig" rid="fig4">Figure 4</xref>) [<xref ref-type="bibr" rid="scirp.67801-ref26">26</xref>] . This</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Comparison of optical NO<sub>2</sub> detection technologies</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >Technology</th><th align="center" valign="middle" >Limit of detection</th><th align="center" valign="middle" >Typical range</th><th align="center" valign="middle" >Reference/Note</th></tr></thead><tr><td align="center" valign="middle"  rowspan="3"  >Chemiluminescence</td><td align="center" valign="middle" >NO<sub>2</sub> detector based on reaction between Luminol and NO<sub>2</sub> in air</td><td align="center" valign="middle" >10 ppt</td><td align="center" valign="middle" >65ppt - 18 ppb</td><td align="center" valign="middle" >Fast response ~1 s [<xref ref-type="bibr" rid="scirp.67801-ref14">14</xref>]</td></tr><tr><td align="center" valign="middle" >Poly-gel Immobilized Luminol NO<sub>2</sub> sensor</td><td align="center" valign="middle" >460 ppt</td><td align="center" valign="middle" >0.5 - 20 ppb</td><td align="center" valign="middle" >The gel substrate needs to be replaced every day [<xref ref-type="bibr" rid="scirp.67801-ref15">15</xref>] .</td></tr><tr><td align="center" valign="middle" >US EPA standard NO<sub>2</sub> test method</td><td align="center" valign="middle" >~1 ppb</td><td align="center" valign="middle" >1 - 500 ppb</td><td align="center" valign="middle" >LOD and range will vary slightly on different conditions [<xref ref-type="bibr" rid="scirp.67801-ref10">10</xref>] .</td></tr><tr><td align="center" valign="middle"  rowspan="4"  >Non- Chemiluminescence</td><td align="center" valign="middle" >Cavity Attenuated Phase Shift (CAPS) NO<sub>2</sub> detector</td><td align="center" valign="middle" >0.3 ppb</td><td align="center" valign="middle" >0.5 - 200 ppb</td><td align="center" valign="middle" >Very fast response, suitable for online monitoring [<xref ref-type="bibr" rid="scirp.67801-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref18">18</xref>]</td></tr><tr><td align="center" valign="middle" >CAPS NO<sub>2</sub> detector, second generation</td><td align="center" valign="middle" >0.06 ppb</td><td align="center" valign="middle" >0 - 320 ppb</td><td align="center" valign="middle" >Improved accuracy and sensitivity [<xref ref-type="bibr" rid="scirp.67801-ref19">19</xref>]</td></tr><tr><td align="center" valign="middle" >Miniature fiber-optic spectroscopy</td><td align="center" valign="middle" >~10 ppb</td><td align="center" valign="middle" >15 - 50 ppb</td><td align="center" valign="middle" >Semi quantitative with a relatively large error (&#177;20%) [<xref ref-type="bibr" rid="scirp.67801-ref20">20</xref>]</td></tr><tr><td align="center" valign="middle" >DPPD-polymer NO<sub>2</sub> detector</td><td align="center" valign="middle" >0.12 ppm</td><td align="center" valign="middle" >0.1 - 25 ppm</td><td align="center" valign="middle" >Small scale integrated sensor [<xref ref-type="bibr" rid="scirp.67801-ref21">21</xref>]</td></tr></tbody></table></table-wrap><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Schematic cross-section of a suspended gate gas sensor [<xref ref-type="bibr" rid="scirp.67801-ref26">26</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7301211x13.png"/></fig><p>platform was based on capacitive coupled field effect transistors (CC-FET). Unlike other common gas sensors, the sensing material in this study was suspended on top of the substrate, which is called suspended gates (SG) [<xref ref-type="bibr" rid="scirp.67801-ref26">26</xref>] . There is a small gap of 1 - 5 μm distance between SG and the FET channel. A schematic illustration is shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>. Therefore, the sensing material can be separated from the platform so that a large variety of materials and substrates can be tested. Sensing thin film can be easily replaced and compared in parallel under exactly the same testing conditions.</p><p>In the past two decades, a great deal of research work has been focused on resistance and conductivity gas sensors [<xref ref-type="bibr" rid="scirp.67801-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref25">25</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref27">27</xref>] - [<xref ref-type="bibr" rid="scirp.67801-ref32">32</xref>] . In this type of sensors, a thin film usually made of semiconductor oxide serves as the main sensing material. Concentration of NO<sub>2</sub> is directly related to resistance and conductivity of the material and is measurable with peripheral circuits. The center of many current research targets at discovering and developing better sensing materials.</p><p>NO<sub>2</sub> is an oxidizing gas so it induces an increase of resistance and impedance of n-type semiconductors. Sensors based on semiconducting metal oxides have been developed and reviewed by a number of researchers [<xref ref-type="bibr" rid="scirp.67801-ref29">29</xref>] . The base material includes tin oxide (SnO<sub>2</sub>), tungsten oxide (WO<sub>3</sub>), indium oxide (In<sub>2</sub>O<sub>3</sub>), titanium oxide (TiO<sub>2</sub>), zinc oxide (ZnO) and other non-metal materials such as polymers and grapheme [<xref ref-type="bibr" rid="scirp.67801-ref28">28</xref>] - [<xref ref-type="bibr" rid="scirp.67801-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref33">33</xref>] - [<xref ref-type="bibr" rid="scirp.67801-ref35">35</xref>] . In addition, doping and use of different additive materials has opened another pathway of developing new sensing materials. Common preparation methods are chemical vapor deposition (CVD), electrophoretic deposition, electrostatic spray, solution precursor plasma-spray and other similar approach. Characterization of the microscopic structure of these materials usually utilizes technologies such as X-ray powder diffraction (XRD), scanning electron microscope (SEM), Transmission electron microscopy (TEM), atomic force microscope (AFM) and X-ray photoelectron spectroscopy (XPS).</p><p>ZnO has been proved to be a stable, low cost and non-toxic sensing material. However, the sheet resistance of pure ZnO thin film is substantially high. If impedance of the sensor becomes higher, the resulting weak signal of current change will considerably increase the complexity of the associated controlling and measuring circuitry of instruments, though sensing of NO<sub>2</sub> is based on the increase of resistance. Data may also become distorted at such week signal levels. Ferro et al. [<xref ref-type="bibr" rid="scirp.67801-ref28">28</xref>] reported indium and cadmium doped ZnO thin films with a lowered resistance and improved performance. Spray pyrolysis was used for its simplicity, low cost and ability for mass production. Undoped ZnO sensor was tested with different film thickness and grain size in order to find an optimized combination. The best amount of doping was 3% w/w. Fast response and recovery was observed at an operating temperature of 275˚C. The effect of gas sensing with the additive was considered not related to electronic catalytic mechanism because increased carrier concentrations by doping deteriorate performance of the sensor. The reaction mechanism was proved to be the increase of the surface active area and the number of active absorbing sites, by using SEM and AFM to examine the surface structure of the doped sensing film. The detectable range of doped ZnO film is 0 - 5 ppm [<xref ref-type="bibr" rid="scirp.67801-ref28">28</xref>] .</p><p>In addition, sensors of oxidizing gases usually utilize high temperature to enhance the desorption kinetics. In studies of gas sensors, response time (T90) is defined as the time required for the signal to reach 90% of the final value upon exposure of the target gas, while the recovery time (T10) is the time for the signal to reduce to 10% of the highest level when the target gas is removed. Slow response and recovery within 10 - 60 min is commonly observed across this type of sensors (<xref ref-type="fig" rid="fig5">Figure 5</xref>) [<xref ref-type="bibr" rid="scirp.67801-ref30">30</xref>] . Several types of sensors that may function at room temperature have been discovered and investigated. However, the lowered temperature may slow down the response and recovery further more. A reported In<sub>2</sub>O<sub>3</sub> nanowire sensor showed a response to sub-ppm level NO<sub>2</sub> in 15 min with a recovery time of 45 - 90 min. [<xref ref-type="bibr" rid="scirp.67801-ref31">31</xref>] Another study by Liu et al. [<xref ref-type="bibr" rid="scirp.67801-ref29">29</xref>] significantly lowered the requirement of high operating temperature, which is usually 300˚C - 500˚C and observed among resistive gas sensors. Kinetic studies have shown that absorption of NO<sub>2</sub> on the surface of sensing materials was much faster than the desorption process.</p><p>Graphene has recently been reported as a potent material for construction of sensors, small-scale electronics and solar cells. The unique wide-spread 2D structure of graphene reassembles a honeycomb lattice, which forms π bonds across the hexagonal skeleton. π bondis half filled and allows free-flowing electrons, which contributes to the most notable electronic properties of graphene, the quantum Hall effect [<xref ref-type="bibr" rid="scirp.67801-ref36">36</xref>] [<xref ref-type="bibr" rid="scirp.67801-ref37">37</xref>] . The selective absorption and desorption was demonstrated by Ko et al. [<xref ref-type="bibr" rid="scirp.67801-ref32">32</xref>] . Unlike other metal oxide thin film gas sensors, adsorption of NO<sub>2</sub> molecule increases of conductivity of graphene sensors. As Zhang et al. suggested there were three possible configurations of the adsorption, the nitro-, nitrite- and cyclo-addition, increase of conductivity of graphene is due to charge transfer between NO<sub>2</sub> molecules and graphene. Desorption has been found to be a very slow process. A possible way to expedite it is to expose the sensor under UV radiation [<xref ref-type="bibr" rid="scirp.67801-ref32">32</xref>] .</p><p>When reduced graphene oxide is sprayed withasoluble semiconducting polymer, a double-layered sensing film is formed. Xie et al. [<xref ref-type="bibr" rid="scirp.67801-ref33">33</xref>] reported that the use of poly-(3-hexylthiophene) (P3HT), which is a p type semiconducting polymer, can enhance the gas sensing properties (<xref ref-type="fig" rid="fig6">Figure 6</xref>). The double-layered material was constructed on an existing organic thin film transistor (OTFT) sensor platform. Pure P3HT thin film was prepared and compared to the double layer of P3HT/Graphene designs. P3HT and/or Graphene layers were applied to the OTFT substrate using an air brushing technique.</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Typical resistance sensor response of NO<sub>2</sub> at different temperature [<xref ref-type="bibr" rid="scirp.67801-ref30">30</xref>] (Re-printed with permission)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7301211x14.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Response of graphene/P3HT double layer gas sensing material [<xref ref-type="bibr" rid="scirp.67801-ref33">33</xref>] (re-printed with permission)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7301211x15.png"/></fig><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Comparison of major detection categories</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Type</th><th align="center" valign="middle" >Pros</th><th align="center" valign="middle" >Cons</th></tr></thead><tr><td align="center" valign="middle" >Chemical</td><td align="center" valign="middle" >Simple processing without the need of expensive equipment/instrument</td><td align="center" valign="middle" >Poor sensitivity; Requires the use of chemicals; Low throughput and high labor demand</td></tr><tr><td align="center" valign="middle" >Optical</td><td align="center" valign="middle" >Highly reliable and fully validated detection with the use of luminal; Very high sensitivity with CAPS detector</td><td align="center" valign="middle" >High cost of instrument purchase and maintenance; Unable to use in small scale sensors</td></tr><tr><td align="center" valign="middle" >FET</td><td align="center" valign="middle" >Solid state sensors without chemicals; Continuously monitoring (on-line analysis)</td><td align="center" valign="middle" >The accuracy and reliability can still be improved by developing new sensing materials</td></tr></tbody></table></table-wrap><p>The response to exposure of NO<sub>2</sub> showed a very interesting three-stage curve, the rapid response, the slow response and the recovery, especially at higher concentrations of NO<sub>2</sub>. The mechanism that caused the 3 stages can be explained that at higher concentrations (over 60 ppm), the rapid rise of signal (stage 1) is due to the adsorption of gas molecules onto low energy bonding sites such as sp2-bonded carbon. With gradual saturation of these sites, the gas molecules will interact with higher energy sites such as vacancies and structural defects, which is much slower (stage 2). Stage 3 showed an exponential decay of the signal when the analyte (NO<sub>2</sub>) was purged out with air. However, at lower NO<sub>2</sub> concentrations, only very few NO<sub>2</sub> molecules can reach to the surface of graphene through the P3HT top layer. The fast responding low energy sites will not be saturated. Thus all the NO<sub>2</sub> molecules interact with the low energy sites, which lead to a relatively fast over-all response.</p><p>One of the major drawbacks of graphene based sensing material is the baseline shift. As showed also in the response curve over time, the recovery of the signal did not go back to the original level, especially after exposure to high levels of NO<sub>2</sub>. Within 90 min, the signal will return to baseline close to the original value, but long recovery is not desirable in practice and needs further investigation for improvement.</p></sec><sec id="s2_4"><title>2.4. Other Detection Technologies</title><p>Besides these dominating detection techniques mentioned above, there are other methods to analyze NO<sub>2</sub>, such as Gas Chromatography/Mass Spectrometry (GC/MS), Residual Gas Analyzer (RGA) and immunochemical methods [<xref ref-type="bibr" rid="scirp.67801-ref38">38</xref>] - [<xref ref-type="bibr" rid="scirp.67801-ref40">40</xref>] . One example is the detection of NO<sub>2</sub> using piezoelectric quartz crystal [<xref ref-type="bibr" rid="scirp.67801-ref11">11</xref>] .Vibration frequency of an oscillating crystal may be decreased by substances that are absorbed on the surface of crystal. Selectivity is achieved by carefully choosing a coating material on the surface of the piezoelectric crystals. In the study by Karmarkar et al., two types of materials, Ucon 75-H-90000 and Ucon-LB-300X were chosen for the specified detection of NO<sub>2</sub> and NH<sub>4</sub>, respectively [<xref ref-type="bibr" rid="scirp.67801-ref11">11</xref>] . Base frequency of the crystal was 9 MHz. A 40 Hz decrease was observed with exposure to about 1 ppm of NO<sub>2</sub> in the sample mixture. The response as change of frequency was linear in the range from 1 ppb to 1 ppm. The response time was about 5 minutes. In short, the piezoelectric crystal is a good detector with high sensitivity, without use of liquid chemicals or moving parts. However, there are drawbacks of this type of detector. First, it responses to atmospheric moisture. It would be difficult to distinguish between the effect of moisture and a true air pollutant. A dry wash device can be used to eliminate moisture content, before the air samples enter the detector. Another drawback is that after a long exposure to air, the detector loses all the detection ability to NO<sub>2</sub>. This disability may be reversed by exposing the detector to NO<sub>2</sub> mixture again for a short time [<xref ref-type="bibr" rid="scirp.67801-ref11">11</xref>] .</p></sec></sec><sec id="s3"><title>3. Summary</title><p>A brief review of NO<sub>2</sub> analysis technologies has been presented in this paper. The advantages and disadvantages of the categories are compared in <xref ref-type="table" rid="table2">Table 2</xref>.</p><p>The research of NO<sub>2</sub> detection has gone a long way from the first discovery of chemiluminescence with Luminol. The reviewed technologies were classified into categories by the sensing properties. Selected important studies that represent the key characteristics are included. Factors that affect the sensing characters are analyzed. Trends of improvements are also discussed. The current active studies of NO<sub>2</sub> analysis focus on two major paths. One is the environmental analysis regulated by the EPA or other governments, which is also known as the regulatory measurements. Another more cutting edge area of study is the development of gas sensing material, especially semi-conductive thin films. These materials have great potential of applications on versatile, solid state, small scale and maintenance-free devices.</p></sec><sec id="s4"><title>Cite this paper</title><p>Jun Wang,Wei Zhang,Rui Cao,Xiangyu You,Hong Lai, (2016) Analysis of Nitrogen Dioxide in Environment. Advances in Bioscience and Biotechnology,07,278-288. doi: 10.4236/abb.2016.76026</p></sec><sec id="s5"><title>Abbreviation List</title><p>NO<sub>2</sub>: nitrogen dioxide</p><p>US: United States of America</p><p>EPA: Environmental Protection Agency</p><p>NH<sub>3</sub>: ammonia</p><p>PMT: photon multiplier tube</p><p>CAPS: cavity attenuated phase shift</p><p>FET: field-effect transistor</p><p>IC: integrated circuit</p><p>NO: nitric oxide</p><p>O<sub>3</sub>: ozone</p><p><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-7301211x16.png" xlink:type="simple"/></inline-formula>: exited state of nitrogen dioxide</p><p>NO<sub>x</sub>: nitrogen oxides</p><p>CRDS: cavity ring-down spectroscopy</p><p>IGE-FET: interdigitated gate electrode field-effect transistor</p><p>CuPc: copper phthalocyanine</p><p>CC-FET: capacitive coupled field effect transistors</p><p>SG: suspended gates</p><p>SnO<sub>2</sub>: tin oxide</p><p>WO<sub>3</sub>: tungsten oxide</p><p>In<sub>2</sub>O<sub>3</sub>: indium oxide</p><p>TiO<sub>2</sub>: titanium oxide</p><p>ZnO: zinc oxide</p><p>CVD: chemical vapor deposition</p><p>XRD: X-ray powder diffraction</p><p>SEM: scanning electron microscope</p><p>TEM: Transmission electron microscopy</p><p>AFM: atomic force microscope</p><p>XPS: X-ray photoelectron spectroscopy</p><p>P3HT: poly-(3-hexylthiophene</p><p>OTFT: organic thin film transistor</p><disp-formula id="scirp.67801-formula1400"><graphic  xlink:href="http://html.scirp.org/file/3-7301211x17.png"  xlink:type="simple"/></disp-formula><p>Submit your manuscript at: http://papersubmission.scirp.org/</p></sec><sec id="s6"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.67801-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Shi, Y., Xia, Y., Lu, B., Liu, N., Zhang, L., Li, S. and Li, W. (2014) Emission Inventory and Trends of NOx for China, 2000-2020. Journal of Zhejiang University SCIENCE A, 15, 454-464. http://dx.doi.org/10.1631/jzus.A1300379</mixed-citation></ref><ref id="scirp.67801-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Wilkins, C., Clausen, P., Wolkoff, P., Larsen, S., Hammer, M., Larsen, K., Hansen, V. and Nielsen, G. (2001) Formation of Strong Airway Irritants in Mixtures of Isoprene/Ozone and Isoprene/Ozone/Nitrogen Dioxide. Environ Health Perspect, 109, 937-941. http://dx.doi.org/10.1289/ehp.01109937</mixed-citation></ref><ref id="scirp.67801-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Hamra, G., Laden, F., Cohen, A., Raaschou-Nielsen, O., Brauer, M. and Loomis, D. (2015) Lung Cancer and Exposure to Nitrogen Dioxide and Traffic: A Systematic Review and Meta-Analysis. Environ Health Perspect, 123, 111. http://dx.doi.org/10.1289/ehp.1408882</mixed-citation></ref><ref id="scirp.67801-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Rohde, R. and Muller, R. (2015) Air Pollution in China: Mapping of Concentrations and Sources. PLoS ONE, 10, e0135749. http://dx.doi.org/10.1371/journal.pone.0135749</mixed-citation></ref><ref id="scirp.67801-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">International Agency for Research on Cancer (IARC) (2013) Outdoor Air Pollution a Leading Environmental Cause of Cancer Deaths. World Health Org. Press Release No. 221.</mixed-citation></ref><ref id="scirp.67801-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">National Ambient Air Quality Standards (1971) US Code of Federal Regulations. 36 FR 8186 Apr. 30.</mixed-citation></ref><ref id="scirp.67801-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">(2014) National Trends in Nitrogen Dioxide Levels 1980-2014. US EPA Publication, Washington DC.</mixed-citation></ref><ref id="scirp.67801-ref8"><label>8</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Kjeldahj</surname><given-names> J. </given-names></name>,<etal>et al</etal>. (<year>1883</year>)<article-title>Neue Methodezur Bestimmung des Stickstoffs in organischen Korpern</article-title><source> Zeitschrift für Analytische Chemie</source><volume> 1</volume>,<fpage> 366</fpage>-<lpage>383</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.67801-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Ferrari, A. (1960) Nitrogen Determination by a Continuous Digestion and Analysis System. Annals of the New York Academy of Sciences, 87, 792-800. http://dx.doi.org/10.1111/j.1749-6632.1960.tb23236.x</mixed-citation></ref><ref id="scirp.67801-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">US EPA Quality Assurance Guidance Document 2.3 Reference (2002) Method for the Determination of Nitrogen Dioxide in the Atmosphere.</mixed-citation></ref><ref id="scirp.67801-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Karmarkar, K. and Guilbault, G. (1975) The Detection of Ammonia and Nitrogen Dioxide at the Parts per Billion Level with Coated Piezoelectric Crystal Detectors. Analytica Chimica Acta, 75, 111-117. http://dx.doi.org/10.1016/S0003-2670(01)81958-9</mixed-citation></ref><ref id="scirp.67801-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Nakai, K. and Mason, R.P. (2005) Immunochemical Detection of Nitric Oxide and Nitrogen Dioxide Trapping of the Tyrosyl Radical and the Resulting Nitrotyrosine in Sperm Whale Myoglobin. Free Radical Biology &amp; Medicine, 39, 1050-1058. http://dx.doi.org/10.1016/j.freeradbiomed.2005.05.019</mixed-citation></ref><ref id="scirp.67801-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Fontijn, A., Meyer, C. and Schiff, H. (1964) Absolute Quantum Yield Measurements of the NO–O Reaction and Its Use as a Standard for Chemiluminescent Reactions. The Journal of Chemical Physics, 40, 64. http://dx.doi.org/10.1063/1.1724895</mixed-citation></ref><ref id="scirp.67801-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Wendel, G., Stedman, D. and Cantrell, C. (1983) Luminol-Based Nitrogen Dioxide Detector. Analytical Chemistry, 55, 937-940. http://dx.doi.org/10.1021/ac00257a027</mixed-citation></ref><ref id="scirp.67801-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Collins, G. and Rose-Pehrsson, S. (1995) Chemiluminescent Chemical Sensors for Oxygen and Nitrogen Dioxide. Analytical Chemistry, 67, 2224-2230. http://dx.doi.org/10.1021/ac00109a049</mixed-citation></ref><ref id="scirp.67801-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Huntress, E., Stanley, L. and Parker, A. (1934) The Preparation of 3-Aminophthalhydrazide for Use in the Demonstration of Chemiluminescence. Journal of the American Chemical Society, 56, 241-242. http://dx.doi.org/10.1021/ja01316a077</mixed-citation></ref><ref id="scirp.67801-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Kebabian, P., Wood, E., Herndon, S. and Freedman, A. (2005) Detection of Nitrogen Dioxide by Cavity Attenuated Phase Shift Spectroscopy. Analytical Chemistry, 77, 724-728.</mixed-citation></ref><ref id="scirp.67801-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Weeksrtom, K. (2004) US Patent No. 6791689 B1.</mixed-citation></ref><ref id="scirp.67801-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Kebabian, P., Wood, E., Herndon, S. and Freedman, A. (2008) A Practical Alternative to Chemiluminescence-Based Detection of Nitrogen Dioxide: Cavity Attenuated Phase Shift Spectroscopy. Environmental Science &amp; Technology, 42, 6040-6045. http://dx.doi.org/10.1021/es703204j</mixed-citation></ref><ref id="scirp.67801-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Morales, J. and Walsh, J. (2005) Detection of Atmospheric Nitrogen Dioxide Using a Miniaturised Fibre-Optic Spectroscopy System and the Ambient Sunlight. Spectrochimica Acta Part A, 61, 2073-2079. http://dx.doi.org/10.1016/j.saa.2004.08.007</mixed-citation></ref><ref id="scirp.67801-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Alexy, M., Hanko, M., Rentmeister, S. and Heinze, J. (2006) Disposable Optochemical Sensor Chip for Nitrogen Dioxide Detection Based on Oxidation of N,N’-Diphenyl-1,4-Phenylenediamine. Sensors and Actuators B, 114, 916-927. http://dx.doi.org/10.1016/j.snb.2005.08.041</mixed-citation></ref><ref id="scirp.67801-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Kebabian, P., Herndon, S. and Freedman, A. (2005) Detection of Nitrogen Dioxide by Cavity Attenuated Phase Shift Spectroscopy. Analytical Chemistry, 77, 724-728. http://dx.doi.org/10.1021/ac048715y</mixed-citation></ref><ref id="scirp.67801-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Wheeler, M.D. and Newman, S.M. (1998) Cavity Ring-Down Spectroscopy. Journal of the Chemical Society, Faraday Transactions, 94, 337-351. http://dx.doi.org/10.1039/a707686j</mixed-citation></ref><ref id="scirp.67801-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Herbelin, J.M. and McKay, J.A. (1981) Development of Laser Mirrors of Very High Reflectivity Using the Cavity-Attenuated Phase-Shift Method. Applied Optics, 20, 3341-3344. http://dx.doi.org/10.1364/AO.20.003341</mixed-citation></ref><ref id="scirp.67801-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Kolesar Jr., E. and Wiseman, J. (1989) Interdigitated Gate Electrode Field Effect Transistor for the Selective Detection of Nitrogen Dioxide and Diisopropyl Methylphosphonate. Analytical Chemistry, 61, 2355-2361. http://dx.doi.org/10.1021/ac00196a008</mixed-citation></ref><ref id="scirp.67801-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Oprea, A., Frerichs, H., Wilbertz, C., Lehmann, M. and Weimar, U. (2007) Hybrid Gas Sensor Platform Based on Capacitive Coupled Field Effect Transistors: Ammonia and Nitrogen Dioxide Detection. Sensors and Actuators B, 127, 161-167. http://dx.doi.org/10.1016/j.snb.2007.07.030</mixed-citation></ref><ref id="scirp.67801-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Eisele, I., Doll, T. and Burgmair, M. (2001) Low Power Gas Detection with FET Sensors. Sensors and Actuators B, 78, 19-25. http://dx.doi.org/10.1016/S0925-4005(01)00786-9</mixed-citation></ref><ref id="scirp.67801-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Ferro, R., Rodríguez, J. and Bertrand, P. (2008) Peculiarities of Nitrogen Dioxide Detection with Sprayed Undoped and Indium-Doped Zinc Oxide Thin Films. Thin Solid Films, 516, 2225-2230. http://dx.doi.org/10.1016/j.tsf.2007.07.189</mixed-citation></ref><ref id="scirp.67801-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Liu, H., Wan, J., Fu, Q., Li, M., Luo, W., Zheng, Z., Cao, H., Hu, Y. and Zhou, D. (2013) Tin Oxide Films for Nitrogen Dioxide Gas Detection at Low Temperatures. Sensors and Actuators B, 177, 460-466. http://dx.doi.org/10.1016/j.snb.2012.11.051</mixed-citation></ref><ref id="scirp.67801-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, C., Genga, X., Olivier, M., Liao, H. and Debliquy, M. (2014) Solution Precursor Plasma-Sprayed Tungsten Oxide Coatings for Nitrogen Dioxide Detection. Ceramics International, 40, 11427-11431.http://dx.doi.org/10.1016/j.ceramint.2014.03.109</mixed-citation></ref><ref id="scirp.67801-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Surwade, S., Agnihotra, S., Dua, V. and Manohar, S. (2009) Nitrogen Dioxide Vapor Detection Using Poly-o- Toluidine. Sensors and Actuators B, 143, 454-457. http://dx.doi.org/10.1016/j.snb.2009.09.033</mixed-citation></ref><ref id="scirp.67801-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Ko, G., Kim, H.-Y., Ahn, J., Park, Y.-M., Lee, K.-Y. and Kim, J. (2010) Graphene-Based Nitrogen Dioxide Gas Sensors. Current Applied Physics, 10, 1002-1004. http://dx.doi.org/10.1016/j.cap.2009.12.024</mixed-citation></ref><ref id="scirp.67801-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Xie, T., Xie, G., Zhou, Y., Huang, J., Wu, M., Jiang, Y. and Tai, H. (2014) Thin Film Transistors Gas Sensors Based on Reduced Graphene Oxide Poly(3-Hexylthiophene) Bilayer Film for Nitrogen Dioxide Detection. Chemical Physics Letters, 614, 275-281. http://dx.doi.org/10.1016/j.cplett.2014.09.028</mixed-citation></ref><ref id="scirp.67801-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Choi, Y.J., Hwang, I.S., Park, J.G., Choi, K.J., Park, J.H. and Lee, J.H. (2008) Novel Fabrication of an SnO2 Nanowire Gas Sensor with High Sensitivity. Nanotechnology, 19, Article ID: 095508. http://dx.doi.org/10.1088/0957-4484/19/9/095508</mixed-citation></ref><ref id="scirp.67801-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Nalagea, S.R., Navalea, S.T., Manec, R.S., Naushadd, M, Stadlarb, F.J. and Patila, V.B. (2015) Preparation of Camphor-Sulfonic Acid Doped PPy-NiO Hybrid Nanocomposite for Detection of Toxic Nitrogen Dioxide. Synthetic Metals, 209, 426-433. http://dx.doi.org/10.1016/j.synthmet.2015.08.018</mixed-citation></ref><ref id="scirp.67801-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Y., Tan, Y., Stormer, H.L. and Kim, P. (2005) Experimental Observation of the Quantum Hall Effect and Berry’s Phase in Grapheme. Nature, 438, 201-204. http://dx.doi.org/10.1038/nature04235</mixed-citation></ref><ref id="scirp.67801-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Geim, A.K. and Novoselov, K.S. (2007) The Rise of Grapheme. Nature Materials, 6, 183-191. http://dx.doi.org/10.1038/nmat1849</mixed-citation></ref><ref id="scirp.67801-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">King, W.H. (1974) Piezoelectric Sorption Detector. Analytical Chemistry, 36, 1735-1739. http://dx.doi.org/10.1021/ac60215a012</mixed-citation></ref><ref id="scirp.67801-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Finklea, H.O., Zhang, W., Jony, M. and Demirgok, B. (2015) Mass Spectrometry of SOFC Fuel Mixtures Containing Phosphine. Journal of the Electrochemical Society, 162, F1101-F1105. http://dx.doi.org/10.1149/2.1051509jes</mixed-citation></ref><ref id="scirp.67801-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Reston, R.R. and Kolesar, E. (1994) Silicon-Micromachined Gas Chromatography System Used to Separate and Detect Ammonia and Nitrogen Dioxide. I. Design, Fabrication, and Integration of the Gas Chromatography System. Journal of Microelectromechanical Systems, 3, 134-146.http://dx.doi.org/10.1109/84.338634</mixed-citation></ref></ref-list></back></article>