<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">CS</journal-id><journal-title-group><journal-title>Circuits and Systems</journal-title></journal-title-group><issn pub-type="epub">2153-1285</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/cs.2016.78106</article-id><article-id pub-id-type="publisher-id">CS-67159</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Computer Science&amp;Communications</subject><subject> Engineering</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Design and Efficient Controller for Micro Turbine System
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>G.</surname><given-names>Saravanan</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>I.</surname><given-names>Gnanambal</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Electrical and Electronics Engineering, Sona College of Technology, Salem, India</addr-line></aff><aff id="aff2"><addr-line>Department of Electrical and Electronics Engineering, Government College of Engineering, Salem, India</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>gsarangokul@yahoo.com(GS)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>02</day><month>06</month><year>2016</year></pub-date><volume>07</volume><issue>08</issue><fpage>1224</fpage><lpage>1232</lpage><history><date date-type="received"><day>18</day>	<month>March</month>	<year>2016</year></date><date date-type="rev-recd"><day>accepted</day>	<month>20</month>	<year>April</year>	</date><date date-type="accepted"><day>7</day>	<month>June</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this modern era, power generation seems to be a very demanding factor. New models and methods have been proposed to derive from various natural and manmade resources. In such instances, this paper gives a detailed report on the power generation from Micro Turbines. Micro
   
  turbine plays a very important role in electric power generation. Especially they are used in the
   
  combined cycle process power plants. The parameters of Rowen’s model 265-MW single shaftheavy duty gas turbines which are used in dynamic studies are estimated in this paper using the operational and performance data. These data are also used to briefly explain the extraction of parameters of the used model. Micro turbine parameters are approximated using simple thermodynamics assumptions. Micro turbine power generation seems to be an uprising and a promising
   
  source and an exact design with a perfect model is capable of producing the highest efficiency.
   
  Thus this paper is proposed on the aspects of social awareness to elaborate the control design of
   
  Micro Turbine Power Generation System. The parameters of micro turbine models are derived
   
  and the results of several simulated tests using Matlab/Simulink are presented.
 
</p></abstract><kwd-group><kwd>Dynamic Simulation</kwd><kwd> Micro Turbine</kwd><kwd> Control Design</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Generally distributed generation technologies can be classified into the following: micro turbine generation, wind generation, photovoltaic generation and diesel engine generation. As micro turbine has the characteristics of low cost, high efficiency, long life and convenient use, it is regarded as one of the best promising ways of distributed generation. Micro turbines are effective and simplistic in their design for small scale power generation. They also have secure and reliable operating systems. Micro turbine is widely used in distributed power and combined heat and power applications. Micro turbines are small gas turbines which burn gaseous or liquid fuels to create a high energy gas stream that operates an electric generator. Micro turbines are capable of burning number of fuels at high and low pressure levels. The pressure ratio over the compressor is low, around 4, compared to other gas turbines. The compressor and the turbine are 0.15 m in diameter and the entire enclosure is only 2.92 &#215; 1.90 &#215; 0.87 meters. This makes installation easy.</p><p>Micro turbine is small combustion turbine, which is approximately the size of a refrigerator, with outputs of 25 kW to 500 kW. It thus provides a variety of opportunities to meet the applications of distributed power systems. Distributed generation provides a wide range of services to consumers and utilities, including standby generation, peak shaving capability, base load generation and co-generation. Our proposed system develops several models with different degrees of simplification for the representation of gas turbines in dynamic studies have introduced, amongst which the IEEE model for combined cycle power plants had deeper sight into internal processes. The paper is organized into existing systems, proposed system, implementation and its performance. Literature related with the proposed systems is discussed in Chapter 2. Chapter 3 deals with the working progress of micro turbine. Chapter 4 discusses the mechanism used for the control systems for a 265-MW Micro Turbine. The performance analysis is detailed in Chapter 5. Chapter 6 concludes with a few points as to the scope for future enhancement.</p></sec><sec id="s2"><title>2. Literature Survey</title><p>[<xref ref-type="bibr" rid="scirp.67159-ref1">1</xref>] presents the results of an investigation regarding the electrical performance characteristics of a new, three-phase, 480 V (L-L), 30 kW, micro-turbine generator and its suitability as an electrical power source for applications at the electrical power distribution voltage level. In this work [<xref ref-type="bibr" rid="scirp.67159-ref2">2</xref>] discusses micro-turbine and fuel cell models, and the instanteous power issue. [<xref ref-type="bibr" rid="scirp.67159-ref3">3</xref>] presents simplified slow dynamic model for micro turbines and fuel cells. Their stand-alone dynamic performances are analyzed and evaluated. It is illustrated that micro turbines and fuel cells are capable of providing load following service, significantly enhancing their economic value. Recently, more attention has been paid to the high-speed generator driven by micro-turbine due to its simple structure and high power density. In this work [<xref ref-type="bibr" rid="scirp.67159-ref4">4</xref>] , a method to reduce harmonic current in high-speed generator for a distributed power system is presented. Because no additional hardware is needed, the proposed method can be used for various power systems. The detecting and eliminating method of harmonic current components based on hysteresis control strategy of the active power filter using start-up inverter are discussed in detail. In this work [<xref ref-type="bibr" rid="scirp.67159-ref5">5</xref>] develops the model of a PMSG wind turbine and then simulates short circuits to evaluate the performance of the system during short circuit fault.</p><p>Since PMSG wind turbine systems use a double conversion converter, this paper develops two methods for controlling the converter, a new protection method for capacitor over voltage is also evaluated in this paper [<xref ref-type="bibr" rid="scirp.67159-ref6">6</xref>] . The interconnection of MW scale micro-turbine as a set of small, modular generation system at the LV distribution level has a significant impact on micro-grid performance.</p><p>According to the dynamic characteristics of the Micro-turbine system, a complete mathematic model which considers the Micro-turbine and other electrical components as a whole is established in PACAD/EMTDC. In [<xref ref-type="bibr" rid="scirp.67159-ref7">7</xref>] , the parameters of rowan’s model for heavy duty gas turbines in dynamic studies are estimated by use of available operational and performance data. A 172-MW simple cycle, single shaft heavy duty gas turbine and its available operational data are also presented and studied for deriving the parameters of the model.gas turbine parameters are approximated by using simple thermodynamic assumptions, resulting in good corresponding with typical values. In this work presents modeling [<xref ref-type="bibr" rid="scirp.67159-ref8">8</xref>] and performance analysis of MTG system in grid connected and islanding modes of operation. The modeling of a single-shaft micro-turbine generation system suitable for isolated distributed generation applications has been discussed in [<xref ref-type="bibr" rid="scirp.67159-ref9">9</xref>] . Relative researches have also been done on the modeling of micro turbine system [<xref ref-type="bibr" rid="scirp.67159-ref10">10</xref>] .</p></sec><sec id="s3"><title>3. Micro Turbine</title><p>Industrial heavy duty gas turbines are specially designed gas turbines for power generation which are specified by their long life and higher availability compared other types of gas turbines. Micro turbines are designed to operate for long periods with less maintenance. There are two major types of operation of micro turbines―one with single shaft and the other with split-shaft design. The basic components of a micro turbine are compressor, turbine generator and recuperator as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. The heart of the Micro turbine is the compressor-turbine</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The basic component of micro turbine</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x6.png"/></fig><p>unit, which is commonly mounted on a single shaft along with the electrical generator.</p><p>The working progress of the micro turbine can be described as follows: air, at atmosphere pressure, enters the Micro turbine at the compressor inlet. When the air is compressed to achieve the most favourable conditions for combustion, fuel gas is mixed with the compressed air in the combustion chamber. This result in combustion of fuel and the hot exhaust gases are expanded through the turbine to produce the mechanical power.</p><p>The system is considered to operate under normal operating conditions and the fast dynamics of the micro turbine (e.g., start-up, shutdown, internal faults and loss of power) are neglected. Speed control is operated on the speed error, which is computed as the difference between a reference speed and the Micro turbine generation rotor speed. It is usually modeled by using a lead-lag transfer function; and is the primary means of control for the Micro turbine under partial load conditions.</p><p>The output of the governor goes to a low value select to produce a value for V<sub>ce</sub><sub>,</sub> the fuel demand signal. If the operating speed of the system is close to its rated speed, the acceleration control could be eliminated in the modeling. The output of low value selector represents the least amount of fuel required for that particular operating point and is denoted as “V<sub>ce</sub>”. The per unit value for “V<sub>ce</sub>” corresponds directly to the per unit value of mechanical power on turbine base in steady state. The output of the low value selector is compared with maximum and minimum limits. The maximum limit acts as back up to temperature control and is not encountered in normal operation and minimum limit is more important dynamically. The output of the “V<sub>ce</sub>” limiter is multiplied by 0.77 and offset by no load fuel flow value to ensure the continuous combustion process. The fuel flow controls are represented by series of blocks including the valve position and flow dynamics.</p><p>The other signal into the low value select is from the temperature controller. The fuel flow, burned in the combustor results in turbine torque and in exhaust gas temperature measured by a thermocouple. The output from the thermocouple is compared with a reference value, which is usually higher. This enables the temperature control output to remain on the maximum limit, thus resulting in uninhibited governor/speed control. When the thermocouple output exceeds the reference temperature, the temperature control output starts decreasing. When this output becomes lower than the governor output, the former value will pass through the low value select to limit the output, and the unit will operate on temperature control.</p></sec><sec id="s4"><title>4. Controller for Micro Turbine</title><p>Turbine is a linear, dynamic device with the exception of the rotor time constant. The rotor time constant is attributed to two transport delays―one is the time lag associated with the compressor discharge volume; and the other is due to the transport of gas from the combustion system through the turbine. Both the torque and exhaust temperature characteristics of the single shaft Micro turbine is linear with respect to fuel flow and turbine speed. The Micro turbine behavior forces its dynamic model to have small delays and lag time constants. The time delays in the Micro turbine are the combustion reaction delay and the delay seen by the exhaust system and turbine to transport the fluid to the measuring point. The combustion reaction delay is between the fuel injection and heat release in the combustor, while the second delay is between the fuel combustion and exhaust temperature measuring system. A relatively higher time lag exists in the compressor discharge path to turbine inlet. The overall control model of the Micro turbine is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The values of the controller parameters obtained are in the range of the typical values which are usually used for Micro turbine dynamic models [<xref ref-type="bibr" rid="scirp.67159-ref11">11</xref>] .</p></sec><sec id="s5"><title>5. Model Simulation</title><p>The derived and assumed parameters in previous section are used to simulate the behavior of 265-MW micro turbine. In <xref ref-type="table" rid="table1">Table 1</xref>, all parameters of model in <xref ref-type="fig" rid="fig2">Figure 2</xref> are reviewed and listed again. All obtained values of the controllers parameters are in the range of the typical values which are usually used for Micro turbine dynamic models.</p>Results and Discussion<p>A 265-MW Micro turbine is simulated against two cases of −0.1% and −0.5% step decrease in speed, while operating in nominal conditions. The speed-governor droop of 4% is assumed for the simulation.</p><p>Considering the case of −0.1% step decrease in speed, the value of 1.02 p.u is observed for the mechanical power as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows the exhaust temperature of the gas turbine which is measured by the thermocouple, where a final steady state temperature of 585˚C is observed and the temperature control is not activated. The Output of the frequency-load controller (F<sub>D</sub>) is all time lower than the output of the temperature controller (Tc) as shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. The frequency-load controller (F<sub>D</sub>) output, which is the lowest value as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>, is then given as input to the saturation block. The output of this block is shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>. Therefore, the frequency-load controller output passes through the minimum gate and controls the fuel flow to the combustion chamber, which is shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Simulation model of micro turbine controller</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x7.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Parameters values of micro turbine controller</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Components</th><th align="center" valign="middle" >Parameters</th><th align="center" valign="middle" >Rating values</th></tr></thead><tr><td align="center" valign="middle" >W</td><td align="center" valign="middle" >Speed governor gain = 1/droop</td><td align="center" valign="middle" >25</td></tr><tr><td align="center" valign="middle" >Y</td><td align="center" valign="middle" >Speed governor lag time constant</td><td align="center" valign="middle" >0.05</td></tr><tr><td align="center" valign="middle" >MaxF</td><td align="center" valign="middle" >Fuel demand signal upper limit</td><td align="center" valign="middle" >1.5</td></tr><tr><td align="center" valign="middle" >MinF</td><td align="center" valign="middle" >Fuel demand signal lower limit</td><td align="center" valign="middle" >−0.07</td></tr><tr><td align="center" valign="middle" >K<sub>NL</sub></td><td align="center" valign="middle" >No load fuel consumption</td><td align="center" valign="middle" >0.16</td></tr><tr><td align="center" valign="middle" >K<sub>F</sub></td><td align="center" valign="middle" >Fuel system external feedback loop gain</td><td align="center" valign="middle" >0</td></tr><tr><td align="center" valign="middle" >B</td><td align="center" valign="middle" >Valve system transfer function coefficient</td><td align="center" valign="middle" >0.04</td></tr><tr><td align="center" valign="middle" >C</td><td align="center" valign="middle" >Fuel system transfer function coefficient</td><td align="center" valign="middle" >1</td></tr><tr><td align="center" valign="middle" >T<sub>FS</sub></td><td align="center" valign="middle" >Fuel system time constant</td><td align="center" valign="middle" >0.31</td></tr><tr><td align="center" valign="middle" >E<sub>CR</sub></td><td align="center" valign="middle" >Combustion reaction time delay</td><td align="center" valign="middle" >0.05</td></tr><tr><td align="center" valign="middle" >E<sub>TD</sub></td><td align="center" valign="middle" >Turbine and exhaust delay</td><td align="center" valign="middle" >0.04</td></tr><tr><td align="center" valign="middle" >T<sub>CD</sub></td><td align="center" valign="middle" >Compressor discharge volume time constant</td><td align="center" valign="middle" >0.142</td></tr><tr><td align="center" valign="middle" >T<sub>R</sub></td><td align="center" valign="middle" >Turbine rated exhaust temperature</td><td align="center" valign="middle" >585.6</td></tr><tr><td align="center" valign="middle" >A</td><td align="center" valign="middle" >Gas turbine torque block parameter</td><td align="center" valign="middle" >−0.117</td></tr><tr><td align="center" valign="middle" >B</td><td align="center" valign="middle" >Gas turbine torque block parameter</td><td align="center" valign="middle" >1.1169</td></tr><tr><td align="center" valign="middle" >C</td><td align="center" valign="middle" >Gas turbine torque block parameter</td><td align="center" valign="middle" >0.5</td></tr><tr><td align="center" valign="middle" >D</td><td align="center" valign="middle" >Gas turbine exhaust block parameter</td><td align="center" valign="middle" >492.6</td></tr><tr><td align="center" valign="middle" >E</td><td align="center" valign="middle" >Gas turbine exhaust block parameter</td><td align="center" valign="middle" >351.36</td></tr><tr><td align="center" valign="middle" >G<sub>SH</sub></td><td align="center" valign="middle" >Radiation shield parameter</td><td align="center" valign="middle" >0.85</td></tr><tr><td align="center" valign="middle" >T<sub>SH</sub></td><td align="center" valign="middle" >Radiation shield time constant</td><td align="center" valign="middle" >12.2</td></tr><tr><td align="center" valign="middle" >T<sub>TR</sub></td><td align="center" valign="middle" >Thermocouple time constant</td><td align="center" valign="middle" >1.7</td></tr><tr><td align="center" valign="middle" >G<sub>TC</sub></td><td align="center" valign="middle" >Temperature controller parameter</td><td align="center" valign="middle" >3.3</td></tr><tr><td align="center" valign="middle" >T<sub>T</sub></td><td align="center" valign="middle" >Temperature controller integration rate</td><td align="center" valign="middle" >250</td></tr><tr><td align="center" valign="middle" >Nc</td><td align="center" valign="middle" >Compressor efficiency</td><td align="center" valign="middle" >0.895</td></tr><tr><td align="center" valign="middle" >nT</td><td align="center" valign="middle" >Turbine efficiency</td><td align="center" valign="middle" >0.895</td></tr></tbody></table></table-wrap><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Mechanical output power after speed drop by −0.1%</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x8.png"/></fig><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Temperature measurement after turbine speed step of −0.1%</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x9.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Temperature controller against −0.1% turbine speed deviation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x10.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Frequency load controller −0.1% turbine speed deviation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x11.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> After saturation against −0.1% micro turbine speed deviation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x12.png"/></fig><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Fuel demand after turbine speed step of −0.1%</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x13.png"/></fig><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Temperature controller against −0.5% turbine speed deviation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x14.png"/></fig><p>The second scenario with −0.5% step in turbine speed would lead to the activation of the temperature control, as shown in <xref ref-type="fig" rid="fig9">Figure 9</xref>. <xref ref-type="fig" rid="fig1">Figure 1</xref>0 shows the mechanical output power, where a final value close to 1.08 p.u is noted. The power output remains constant until temperature control activation, i.e., until 50 sec. The measured exhaust increases during this period, which is ~50 s, until the temperature reaches a value of 625˚C. This is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>1. The temperature control activation forces the exhaust temperature to decline to its rated value of 585˚C at the expense of decrease in the output power, which is illustrated in <xref ref-type="fig" rid="fig1">Figure 1</xref>0. The behavior of the turbine speed deviation after saturation and that of fuel demand is illustrated in <xref ref-type="fig" rid="fig1">Figure 1</xref>2 &amp; <xref ref-type="fig" rid="fig1">Figure 1</xref>3 respectively. <xref ref-type="fig" rid="fig1">Figure 1</xref>4 ensures this meaning where the output of the frequency-load controller (F<sub>D</sub>).</p><fig id="fig10"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Mechanical output power after speed drop by −0.5%</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x15.png"/></fig><fig id="fig11"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>1</label><caption><title> Temperature measurement after turbine speed step of −0.5%</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x16.png"/></fig><fig id="fig12"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>2</label><caption><title> After saturation against −0.5% turbine speed deviation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x17.png"/></fig><fig id="fig13"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>3</label><caption><title> Fuel demand after turbine speed step of −0.5%</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x18.png"/></fig><fig id="fig14"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>4</label><caption><title> Frequency load controller against −0.5% turbine speed deviation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7600551x19.png"/></fig></sec><sec id="s6"><title>6. Conclusion</title><p>This paper proposes a control design of micro turbine generation system. A 265-MW micro turbine model is considered and its parameters are extracted successfully after performing several simulation tests. These parameters can be used in dynamic studies for many purposes. Simple physical law and simplifications can be used by trainers to learn the concepts or make simple numerical examples based on the data of existing units. The simulation tests are conducted using Matlab/Simulink and the results obtained are discussed. As an extension of this work the PI controller is to be replaced by Fuzzy logic controller in a Matlab/Simulink operating system.</p></sec><sec id="s7"><title>Cite this paper</title><p>G. Saravanan,I. Gnanambal, (2016) Design and Efficient Controller for Micro Turbine System. Circuits and Systems,07,1224-1232. doi: 10.4236/cs.2016.78106</p></sec></body><back><ref-list><title>References</title><ref id="scirp.67159-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Etezadi-Amoli, M. and Choma, K. (2001) Electrical Performance Characteristics of a New Micro-Turbine Generator. 2001 IEEE Power Engineering Society Winter Meeting, Columbus, 28 January-1 February 2001, 736-740.</mixed-citation></ref><ref id="scirp.67159-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Lasseter, R. (2001) Dynamic Models for Micro-Turbines and Fuel Cells. Power Engineering Society Summer Meeting, Vancouver, 15-19 July 2001, 761-766.</mixed-citation></ref><ref id="scirp.67159-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Zhu, Y. and Tomsovic, K. (2002) Development of Models for Analyzing the Load Following Performance of Micro turbines and Fuel Cells. Electric Power Systems Research, 62, 1-11. http://dx.doi.org/10.1016/S0378-7796(02)00033-0</mixed-citation></ref><ref id="scirp.67159-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Zong, M., Wang, F.X., Wang, Z. and Zhang, F.G. (2004) Research on Active Power Filter for Distributed Power System of High-Speed Generator Driven by Micro-Turbine Power System Technology. 2004 International Conference on Power System Technology, China, 21-24 November 2004, 788-791.</mixed-citation></ref><ref id="scirp.67159-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Abedini, A. and Nasiri, A. (2007) PMSG Wind Turbine Performance Analysis During Short Circuit Faults. IEEE Canada Electrical Power Conference, Montreal, 25-26 October 2007, 160-165.</mixed-citation></ref><ref id="scirp.67159-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Huang, W., Zhang, J.H., Wu, Z.P. and Niu, M. (2008) Dynamic Modelling and Simulation of a Micro-Turbine Generation System in the Microgrid. 2008 IEEE International Conference on Sustainable Energy Technologies, Singapore, 24-27 November 2008, 345-350.</mixed-citation></ref><ref id="scirp.67159-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Tavakoli, M., Vahidi, B. and Gawlik, W. (2009) An Educational Guide to Extract the Parameters of Heavy Duty Gas Turbines Model in Dynamic Studies on Operational Data. IEEE Transactions on Power Systems, 24, No. 3.</mixed-citation></ref><ref id="scirp.67159-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Nayak, S.K. and Gaonkar, D.N. (2012) Modeling and Performance Analysis of Microturbine Generation System in Grid Connected/Islanding Operation. International Journal of Renewable Energy Research, 2, No. 4.</mixed-citation></ref><ref id="scirp.67159-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">de Mello, F.P. and Ahner, D.J. (1994) Dynamic Models for Combined Cycle Plants in Power Studies. EEE Transactions on Power Systems, 9, 1698-1708. http://dx.doi.org/10.1109/59.336085</mixed-citation></ref><ref id="scirp.67159-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Hannet, L.N. and Khan, A.H. (1993) Combustion Turbine Dynamic Model Validation from Tests. IEEE Transactions on Power Systems, 8, 152-158. http://dx.doi.org/10.1109/59.221261</mixed-citation></ref><ref id="scirp.67159-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Vahidi, B., Tavakoli, M. and Gawlik, W. (2007) Determining Parameters of Turbine’s Model Using Heat Balance Data of Steam Power Unit for Educational Purposes. IEEE Transactions on Power Systems, 22, No. 4. http://dx.doi.org/10.1109/TPWRS.2007.907509</mixed-citation></ref></ref-list></back></article>