<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJO</journal-id><journal-title-group><journal-title>Open Journal of Orthopedics</journal-title></journal-title-group><issn pub-type="epub">2164-3008</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojo.2016.66019</article-id><article-id pub-id-type="publisher-id">OJO-66983</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ma</surname><given-names>Kosukegawa</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Satoshi</surname><given-names>Nagoya</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mitsunori</surname><given-names>Kaya</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mikito</surname><given-names>Sasaki</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Shunichiro</surname><given-names>Okazaki</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Daisuke</surname><given-names>Suzuki</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Toshihiko</surname><given-names>Yamashita</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Department of Musculoskeletal Biomechanics and Surgical Development, Sapporo Medical University, Sapporo, Japan</addr-line></aff><aff id="aff1"><addr-line>Department of Orthopedic Surgery, Sapporo Medical University, Sapporo, Japan</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>imakosukegawa@gmail.com(MK)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>31</day><month>05</month><year>2016</year></pub-date><volume>06</volume><issue>06</issue><fpage>126</fpage><lpage>134</lpage><history><date date-type="received"><day>11</day>	<month>April</month>	<year>2016</year></date><date date-type="rev-recd"><day>accepted</day>	<month>28</month>	<year>May</year>	</date><date date-type="accepted"><day>31</day>	<month>May</month>	<year>2016</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiographs of the hip joint. Methods: Standing and supine plain anteroposterior radiographs of 62 hip joints in which cementless total hip arthroplasty was performed were examined for polyethylene linear wear rate (mm/year), pelvic inclination, and radiological inclination and anatomic anteversion of the acetabular component. Results: All correlation coefficients of measurements of polyethylene linear wear, pelvic inclination angle, anatomical anteversion angle and radiological inclination angle were calculated highly. And by the three-dimensional numerical analysis, anatomic anteversion of the acetabular component had at least some effect on the degree of polyethylene wear. Conclusion: This study suggests that increased anteversion of the acetabular component reduces polyethylene linear wear in metal-on-polyethylene total hiparthroplasty.
 
</p></abstract><kwd-group><kwd>Total Hiparthroplasty</kwd><kwd> Polyethylene Linear Wear</kwd><kwd> Standing Position</kwd><kwd> Settingangle of Acetabular Component</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Implant loosening is a clinical and radiographic complication after metal-on-polyethylene total hip arthroplasty (THA); presence of a large number of worn polyethylene particles is considered a key factor in the onset of periprostheticosteolysis. Younger age, thinner polyethylene, and larger implant head size have been acknowledged for their adverse effects on polyethylene wear [<xref ref-type="bibr" rid="scirp.66983-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.66983-ref2">2</xref>] . The position and implantation angle of the acetabular component is also related to polyethylene wear, with increased abduction shown to be a particularly important postoperative factor, as evaluated on anteroposterior radio graphs of the hip joint. However, the effects of other factors of implantation angle on osteolysis have not been explored.</p><p>Several factors are yet to be investigated, such as anteversion of the acetabular component and change in implantation angle upon pelvic inclination. Lewinnek reported that adequate anteversion of the acetabular component should be 15˚ &#177; 10˚ from a standpoint of dislocation [<xref ref-type="bibr" rid="scirp.66983-ref3">3</xref>] . Widmer also recommended adequate anteversion of the acetabular component to prevent postoperative dislocation, but they did not evaluate polyethylene wear [<xref ref-type="bibr" rid="scirp.66983-ref4">4</xref>] . Another point to be investigated is the effect of pelvic inclination on the acetabular component. Pelvic inclination might change according to the degree of lumbar lordosis in the supine or standing position. We consider that implantation angle of the acetabular component, previously regarded as appropriate in the supine position, might display beyond-normal range of adequate angles based on unexpected change in pelvic inclination. Although weight bearing might induce creep deformity of polyethylene [<xref ref-type="bibr" rid="scirp.66983-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.66983-ref6">6</xref>] , change in implantation angle of the acetabular component has not been evaluated. Therefore, the purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiographs of the hip joint.</p></sec><sec id="s2"><title>2. Materials and Methods</title><sec id="s2_1"><title>2.1. Patients and Methods</title><p>We retrospectively studied 56 patients (4 men and 52 women) who underwent 62 primary or revision THA between 1991 and 2006. The patients comprised 4 men and 58 women with a mean age of 52 years (range, 35 - 70 years) at the time of surgery. The mean weight was 53 kg (range, 35 - 72 kg), 6 patients underwent bilateral hip arthroplasty. The mean follow-up was 122 months (range, 42 - 228 months). The preoperative diagnosis was osteoartgritis in 10 hips, degenerative arthritis of developmental hip dysplasia in 44 hips, rheumatoid arthritis in 4 hips, aseptic loosening in 1 hip, failed bipolar hemiarthroplasty in 2 hips, tuberculous arthritis in 1 hip.</p><p>We examined standing and supine plain anteroposterior radiographs of the hip joint centered on the pubic symphysis, which were obtained at the final follow-up. This study was approved by the hospital science ethics committee of Sapporo Medical University (No 24 - 131) and informed consent was obtained from patients.</p><p>This study included that acetabular component used was either a 300 series Duraloc spiked titanium cementless cup or a 1200 series Duraloc titanium cementless cup (DePuy International, Leeds, United Kingdom) with screw fixation. Cobalt-chromium metal-on-conventional polyethylene Enduron (DePuy International) bearings were used throughout. The diameter of the metal head was 22.225 mm. An AML Plus cementless cylindrical stem or an AML Replica cementless stem (DePuy International) was implanted.</p><p>We exclude patients, 1) radiographs in which the line between the sacrum and the coccyx did not lie on the pubic symphysis, 2) patients who had undergone bilateral THA with a long interval between the 2 operations so as to avoid measurement bias involving the influence of change in right and left pelvic inclinations. However, 6 patients (12 hips) who underwent bilateral THA within a one-year interval were enrolled in this study. We examined standing and supine radiographs for polyethylene linear wear rate (mm/year), pelvic inclination, and radiological inclination and anatomical anteversion of the acetabular component, defined by Murray [<xref ref-type="bibr" rid="scirp.66983-ref7">7</xref>] .</p><p>All measurements were performed using OP-1 radiographic measurement software (Fuji Film Co. Ltd. Tokyo. Japan). Polyethylene linear wear was expressed as the distance between the center of the acetabular component and the femoral head, according to the method of Sugano et al. [<xref ref-type="bibr" rid="scirp.66983-ref8">8</xref>] . Real wear values were compensated by calculating the difference between the measured diameter of the metal head on radiography and the actual diameter of the inserted femoral head. Pelvic inclination was measured according to the method of Doiguchi et al. [<xref ref-type="bibr" rid="scirp.66983-ref9">9</xref>] . Horizontal diameter (T) and vertical diameter (L) of the pelvic cavity on radiography were measured, and pelvic inclination was calculated using the following formulae: −67 &#215; L/T + 55.7 for male hips and −69 &#215; L/T + 61.6 for female hips (<xref ref-type="fig" rid="fig1">Figure 1</xref>). A larger pelvic inclination indicates posterior tilt of the pelvis. radiologicalinc lination of the acetabular component was defined as the angle between the line across the acetabular teardrops and</p><fig-group id="fig1"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The method of radiographic measurement. T: The parallel line to reference line between the bottom of sacroiliac joints and maximal diameter of the pelvic cavity on radiography. L: The vertical line to the reference line and through top of the pubic symphysis (a). Pelvic inclination: The angle of the line between the sacral promontory and top of the pubic symphysis and the X-ray film plane (b).</title></caption><fig id ="fig1_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-2010391x6.png"/></fig></fig-group><p>the line through the maximum diameter of the acetabular component. Anatomic anteversion of the acetabular component was measured according to the method of Visser et al. [<xref ref-type="bibr" rid="scirp.66983-ref10">10</xref>] (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p></sec><sec id="s2_2"><title>2.2. Statistic Analysis</title><sec id="s2_2_1"><title>2.2.1. Comparison the Measurement Result Supine and Standing Position</title><p>Regression line Y = aX + b was found assigned a measurement stnding to variable Y, as supine to variable X.</p></sec><sec id="s2_2_2"><title>2.2.2. Three-Dimensional Numerical Analysis</title><p>We calculated operative anteversion and operative inclination in the following expression based on the anatomical anteversion and radiological inclination in the standing position.</p><disp-formula id="scirp.66983-formula924"><graphic  xlink:href="http://html.scirp.org/file/2-2010391x7.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.66983-formula925"><graphic  xlink:href="http://html.scirp.org/file/2-2010391x8.png"  xlink:type="simple"/></disp-formula><p>A normal vector directs to the plane.</p><p>The three dimensional implantation angle was calculated back from this operative anteversion and operative inclination, and direction of acetabular component opening was showed by a plane parallel to the acetabular component opening with using three-dimensional normal vector. This normal vector <sup>t</sup>(x, y, z) was calculated by using the following rotation matrix when the Y axis represents anteroposteroir direction of pelvis, the X axis represents the bilateral direction and the Z axis represents the upper and lower direction (<xref ref-type="fig" rid="fig3">Figure 3</xref>, Supplemental <xref ref-type="table" rid="table1">Table 1</xref>).</p><disp-formula id="scirp.66983-formula926"><graphic  xlink:href="http://html.scirp.org/file/2-2010391x9.png"  xlink:type="simple"/></disp-formula><p>Normal vectors calculated were projected on the YZ plane and each the side Y and Z divided into three equal parts, consequently, this plane was divided into 9 areas A-I (<xref ref-type="fig" rid="fig4">Figure 4</xref>(a), <xref ref-type="fig" rid="fig4">Figure 4</xref>(b)). We compared mean values of polyethylene linear wear in each area. This analysis was performed with using 3D graph soft ware (RINEARN Graph 3D, Kyoto, Japan).</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Calculation of anatomic anteversion of the implanted acetabular component using the fomula sin α = B/A. A: acetabular component diameter. B: the distance measured from anteroposterior radiographs. α = anatomic antevertion</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-2010391x10.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> The relation between the acetabular component direction and the coordinate. When the left acetabular component is viewed from lateral side, a normal vector directs to the plane parallel to the acetabular compnent opening. All cases were replaced with left side in this figure. The acetabular component directs lateral when X is plus, similary, directs anterior when Y is minus, inferior when Z is minus. All normal vectors directied lateral and anterior, inferior</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-2010391x11.png"/></fig><fig-group id="fig4"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Grouping by directions of normal vectors (a). Each number of hips in 9 areas (b). Normal vectors in the group A, B, C are tend to face to the lateral direction, and normal vectors in the group A, D, G are tend to face to the anterior direction.</title></caption><fig id ="fig4_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-2010391x12.png"/></fig></fig-group></sec></sec></sec><sec id="s3"><title>3. Results</title><sec id="s3_1"><title>3.1. Comparison the Measurement Result Supine and Standing Position</title><p><xref ref-type="table" rid="table1">Table 1</xref> showed regression lines of polyethylene linear wear, pelvic inclination angle, anatomical anteversion angle, radiological inclination angle. All correlation coefficients were calculated highly, 0.84 - 0.89.</p></sec><sec id="s3_2"><title>3.2. Three-Dimensional Numerical Analysis</title><p><xref ref-type="fig" rid="fig4">Figure 4</xref>(b) showed each number of hips in 9 areas. Mean value of polyethylene linear wear, pelvic inclination angle, anatomical anteversion angle, radiological inclination angle and operative anteversion angle were compared in each groups D, E, H, I which included three or more hip joints (<xref ref-type="table" rid="table2">Table 2</xref>).</p><p>Polyethylene linear wear of the group D was tend to be smaller and which of group I larger (p = 0.052).</p></sec></sec><sec id="s4"><title>4. Discussion</title><p>As factors related to increased polyethylene wear, patient characteristics as well as abduction of the acetabular component and femoral offset have been reported in several studies [<xref ref-type="bibr" rid="scirp.66983-ref11">11</xref>] - [<xref ref-type="bibr" rid="scirp.66983-ref15">15</xref>] . Some clinical reports have revealed that increased abduction of the acetabular component resulted in increased polyethylene linear wear [<xref ref-type="bibr" rid="scirp.66983-ref12">12</xref>] [<xref ref-type="bibr" rid="scirp.66983-ref16">16</xref>] . On the other hand, few reports suggest that the implantation angle of the acetabular component does not influence polyethylene wear [<xref ref-type="bibr" rid="scirp.66983-ref17">17</xref>] [<xref ref-type="bibr" rid="scirp.66983-ref18">18</xref>] . Despite many reports focusing on abduction, few have referred to anteversion of the acetabular component.</p><p>In terms of anteversion, appropriate implantation angle of the acetabular component recommended by Lewinnek [<xref ref-type="bibr" rid="scirp.66983-ref3">3</xref>] and Widmer [<xref ref-type="bibr" rid="scirp.66983-ref4">4</xref>] was aimed to prevent of postoperative dislocation of THA, however it was unclear whether polyethylene wear volume was decreased. We evaluated implantation angle of the acetabular component to define the effect for polyethylene wear.</p><p>We compared measurements of polyethylene linear wear, pelvic inclination, anatomical anteversion, radiological inclination in the supine and standing position. As a result, calculated regression lines showed all measurement supine were highly correlated with each measurement standing. Polyethylene linear wear was verified with higher precision in the standing position than supine position. However, we did not find increased polyethylene wear on the basis of change in posture.</p><p>The results of three-dimensional numerical analysis, we investigated that polyethylene linear wear of the group D was tend to be smaller and which of group I larger (p = 0.052). In the present study, when the absolute</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> A regression coefficient and a correlation coefficient calculated with measurements in the supine and standing position</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >slope</th><th align="center" valign="middle" >Y intercept</th><th align="center" valign="middle" >correlation coefficient R</th></tr></thead><tr><td align="center" valign="middle" >WY (mm)</td><td align="center" valign="middle" >0.95</td><td align="center" valign="middle" >0.019</td><td align="center" valign="middle" >0.86</td></tr><tr><td align="center" valign="middle" >PIA (˚)</td><td align="center" valign="middle" >1.28</td><td align="center" valign="middle" >0.46</td><td align="center" valign="middle" >0.84</td></tr><tr><td align="center" valign="middle" >AA (˚)</td><td align="center" valign="middle" >0.78</td><td align="center" valign="middle" >10.62</td><td align="center" valign="middle" >0.89</td></tr><tr><td align="center" valign="middle" >RI (˚)</td><td align="center" valign="middle" >1.06</td><td align="center" valign="middle" >0.43</td><td align="center" valign="middle" >0.86</td></tr></tbody></table></table-wrap><p>WY: polyethylene linear wear, PIA: pelvic inclination angle; AA: anatomical anteversion angle, RI: radiological inclination angle.</p><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> The mean value of polyethylene linear wear, pelvic inclination, anatomical anteversion, radiological inclination and operative anteversion of each groups</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >WY (mm/year)</th><th align="center" valign="middle" >PIA (˚)</th><th align="center" valign="middle" >AA (˚)</th><th align="center" valign="middle" >RI (˚)</th><th align="center" valign="middle" >OA (˚)</th></tr></thead><tr><td align="center" valign="middle" >Total</td><td align="center" valign="middle" >0.118</td><td align="center" valign="middle" >30.2</td><td align="center" valign="middle" >33.1</td><td align="center" valign="middle" >43.6</td><td align="center" valign="middle" >32.1</td></tr><tr><td align="center" valign="middle" >Group D</td><td align="center" valign="middle" >0.095</td><td align="center" valign="middle" >32.8</td><td align="center" valign="middle" >43.0</td><td align="center" valign="middle" >46.5</td><td align="center" valign="middle" >44.6</td></tr><tr><td align="center" valign="middle" >Group E</td><td align="center" valign="middle" >0.128</td><td align="center" valign="middle" >32.0</td><td align="center" valign="middle" >28.2</td><td align="center" valign="middle" >52.0</td><td align="center" valign="middle" >34.3</td></tr><tr><td align="center" valign="middle" >Group H</td><td align="center" valign="middle" >0.116</td><td align="center" valign="middle" >26.5</td><td align="center" valign="middle" >34.9</td><td align="center" valign="middle" >37.6</td><td align="center" valign="middle" >28.1</td></tr><tr><td align="center" valign="middle" >Group I</td><td align="center" valign="middle" >0.141</td><td align="center" valign="middle" >26.8</td><td align="center" valign="middle" >19.3</td><td align="center" valign="middle" >39.3</td><td align="center" valign="middle" >15.8</td></tr></tbody></table></table-wrap><p>value on a Y axis is larger, anteversion is larger. Similarly, when the absolute value on a Z axis is larger, abduction is larger. Therefore normal vectors in the group A, B, C are tend to face to the lateral direction, and normal vectors in the group A, D, G are tend to face to the anterior direction. This result suggested a relevance between polyethylene linear wear and anatomical anteversion, operative anteversion, because larger data of anatomical anteversion and operative anteversion was distributed into group D, also smaller data of anatomical anteversion and operative anteversion was distributed into group I. Although Wan et al. measured anteversion of the acetabular component clinically, they did not refer to polyethylene wear [<xref ref-type="bibr" rid="scirp.66983-ref13">13</xref>] . Patil et al. reported that increased abduction of the acetabular component led to elevated contact stress on the articulation surface, whereas increased anteversion led to decreased contact stress in a finite element model [<xref ref-type="bibr" rid="scirp.66983-ref16">16</xref>] . D’Lima et al. reported similar experimental results [<xref ref-type="bibr" rid="scirp.66983-ref19">19</xref>] .</p><p>Our study revealed that increased anatomic anteversion of the acetabular component resulted in decreased polyethylene wear and confirmed the experimental results of the finite element analysis performed to determine contact stress on the weight-bearing rim.</p><p>Thus, this study proved that anatomic anteversion of the acetabular component had at least some effect on the degree of polyethylene wear.</p><p>This study was limited by a lack of information regarding position of the acetabular component, creep deformity, and deviation of the femoral head in the anteroposterior direction. Further studies will be necessary to investigate polyethylene wear.</p></sec><sec id="s5"><title>5. Conclusions</title><p>We investigated whether anteversion of the acetabular component has an influence on polyethylene linear wear. Standing and supine plain anteroposterior radiographs of 62 hip joints in which total hip arthroplasty was performed were evaluated for polyethylene linear wear rate (mm/year), pelvic inclination, and abduction and anatomic anteversion of the acetabular component.</p><p>Pelvic inclination as well as operative anteversion and anatomic anteversion of the acetabular component increased in the standing position compared with that in the supine position.</p><p>By the three-dimensional numerical analysis, increased anteversion of the acetabular component reduces polyethylene linear wear in metal-on-polyethylene total hip arthroplasty.</p></sec><sec id="s6"><title>Cite this paper</title><p>Ima Kosukegawa,Satoshi Nagoya,Mitsunori Kaya,Mikito Sasaki,Shunichiro Okazaki,Daisuke Suzuki,Toshihiko Yamashita, (2016) Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis. Open Journal of Orthopedics,06,126-134. doi: 10.4236/ojo.2016.66019</p></sec></body><back><ref-list><title>References</title><ref id="scirp.66983-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Devane, P.A. and Horne, J.G. (1999) Assessment of Polyethylene Wear in Total Hip Replacement. Clinical Orthopaedics and Related Research, 369, 59-72. http://dx.doi.org/10.1097/00003086-199912000-00007</mixed-citation></ref><ref id="scirp.66983-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Livermore, J., Ilstrup, D. and Morrey, B. (1990) Effect of Femoral Head Size on Wear of the Polyethylene Acetabular Component. The Journal of Bone &amp; Joint Surgery American Volume, 72, 518-528.</mixed-citation></ref><ref id="scirp.66983-ref3"><label>3</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Lewinnek</surname><given-names> G.E.</given-names></name>,<name name-style="western"><surname> Lewis</surname><given-names> J.L.</given-names></name>,<name name-style="western"><surname> Tarr</surname><given-names> R. Compere</given-names></name>,<name name-style="western"><surname> C.L. and Zimmerman</surname><given-names> J.R. </given-names></name>,<etal>et al</etal>. (<year>1978</year>)<article-title>Dislocations after Total Hip-Replacement Arthroplasties</article-title><source> The Journal of Bone &amp; Joint Surgery American Volume</source><volume> 60</volume>,<fpage> 217</fpage>-<lpage>220</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.66983-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Widmer, K.H. and Zurfluh, B. (2004) Compliant Positioning of Total Hip Components for Optimal Range of Motion. Journal of Orthopaedic Research, 22, 815-821. http://dx.doi.org/10.1016/j.orthres.2003.11.001</mixed-citation></ref><ref id="scirp.66983-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Smith, P.N., Ling, R.S. and Taylor, R. (1999) The Influence of Weight-Bearing on the Measurement of Polyethylene Wear in THA. The Journal of Bone &amp; Joint Surgery British Volume, 81, 259-265. http://dx.doi.org/10.1302/0301-620X.81B2.9154</mixed-citation></ref><ref id="scirp.66983-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Martell, J.M., Leopold, S.S. and Liu, X. (2000) The Effect of Joint Loading on Acetabular Wear Measurement in Total Hip Arthroplasty. The Journal of Arthroplasty, 15, 512-518. http://dx.doi.org/10.1054/arth.2000.4336</mixed-citation></ref><ref id="scirp.66983-ref7"><label>7</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Murray</surname><given-names> D.W. </given-names></name>,<etal>et al</etal>. (<year>1993</year>)<article-title>The Definition and Measurement of Acetabular Orientation</article-title><source> The Journal of Bone &amp; Joint Surgery British Volume</source><volume> 75</volume>,<fpage> 228</fpage>-<lpage>32</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.66983-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Sugano, N., Nishii, T., Nakata, K., Masuhara, K. and Takaoka, K. (1995) Polyethylene Sockets and Alumina Ceramic Heads in Cemented Total Hip Arthroplasty. A Ten-Year Study. The Journal of Bone &amp; Joint Surgery British Volume, 77, 548-556.</mixed-citation></ref><ref id="scirp.66983-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Doiguchi, Y., Iwasaki, K., Yamada, K., Takahashi, K., Teshima, K., Sasamatsu, T., Tomita, M. and Narabayashi, Y. (1992) Correlation between Pelvic Inclination and Radiological Shape of the Pelvic Cavity. Orthopedics &amp; Traumatology, 41, 641-645. (In Japanese) http://dx.doi.org/10.5035/nishiseisai.41.641</mixed-citation></ref><ref id="scirp.66983-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Visser, J.D. and Konings, J.G. (1981) A New Method for Measuring Angles after Total Hip Arthroplasty. A Study of the Acetabular Cup and Femoral Component. The Journal of Bone &amp; Joint Surgery British Volume, 63, 556-559.</mixed-citation></ref><ref id="scirp.66983-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Georgiades, G., Babis, G.C., Kourlaba, G. and Hartofilakidis, G. (2010) Effect of Cementless Acetabular Component Orientation, Position, and Containment in Total Hip Arthroplasty for Congenital Hip Disease. The Journal of Arthroplasty, 25, 1143-1150. http://dx.doi.org/10.1016/j.arth.2009.12.016</mixed-citation></ref><ref id="scirp.66983-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Little, N.J., Busch, C.A., Gallagher, J.A., Rorabeck, C.H. and Bourne, R.B. (2009) Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset. Clinical Orthopaedics and Related Research, 467, 2895-2900. http://dx.doi.org/10.1007/s11999-009-0845-3</mixed-citation></ref><ref id="scirp.66983-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Wan, Z., Boutary, M. and Dorr, L.D. (2008) The Influence of Acetabular Component Position on Wear in Total Hip Arthroplasty. The Journal of Arthroplasty, 23, 51-56. http://dx.doi.org/10.1016/j.arth.2007.06.008</mixed-citation></ref><ref id="scirp.66983-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Bicanic, G., Delimar, D., Delimar, M. and Pecina, M. (2009) Influence of the Acetabular Cup Position on Hip Load during Arthroplasty in Hip Dysplasia. International Orthopaedics, 33, 397-402. http://dx.doi.org/10.1007/s00264-008-0683-z</mixed-citation></ref><ref id="scirp.66983-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Sakalkale, D.P., Sharkey, P.F., Eng, K., Hozack, W.J. and Rothman, R.H. (2001) Effect of Femoral Component Offset on Polyethylene Wear in Total Hip Arthroplasty. Clinical Orthopaedics and Related Research, 388, 125-134. http://dx.doi.org/10.1097/00003086-200107000-00019</mixed-citation></ref><ref id="scirp.66983-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Patil, S., Bergula, A., Chen, P.C., Colwell Jr., C.W. and D’Lima, D.D. (2003) Polyethylene Wear and Acetabular Component Orientation. The Journal of Bone &amp; Joint Surgery American Volume, 85, 56-63.</mixed-citation></ref><ref id="scirp.66983-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Goosen, J.H., Verheyen, C.C. and Tulp, N.J. (2005) Mid-Term Wear Characteristics of an Uncemented Acetabular Component. The Journal of Bone &amp; Joint Surgery British Volume, 87, 1475-1479. http://dx.doi.org/10.1302/0301-620X.87B11.16101</mixed-citation></ref><ref id="scirp.66983-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Del Schutte Jr., H., Lipman, A.J., Bannar, S.M., Livermore, J.T., Ilstrup, D. and Morrey, B.F. (1998) Effects of Acetabular Abduction on Cup Wear Rates in Total Hip Arthroplasty. The Journal of Arthroplasty, 13, 621-626. http://dx.doi.org/10.1016/S0883-5403(98)80003-X</mixed-citation></ref><ref id="scirp.66983-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">D’Lima, D.D., Chen, P.C. and Colwell Jr., C.W. (2001) Optimizing Acetabular Component Position to Minimize Impingement and Reduce Contact Stress. The Journal of Bone &amp; Joint Surgery American Volume, 83, 87-91.</mixed-citation></ref></ref-list></back></article>