<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SGRE</journal-id><journal-title-group><journal-title>Smart Grid and Renewable Energy</journal-title></journal-title-group><issn pub-type="epub">2151-481X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/sgre.2011.23034</article-id><article-id pub-id-type="publisher-id">SGRE-6564</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Earth&amp;Environmental Sciences</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Sizing of Converters Interfacing the Rotor of Wind Driven DFIG to the Power Grid
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ahmoud</surname><given-names>Abdel Halim Saleh</given-names></name><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mona</surname><given-names>Naguib Eskander</given-names></name><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><author-notes><corresp id="cor1">* E-mail:<email>salehmahmoud36@yahoo.com(AAHS)</email>;<email>eskander@eri.sci.eg(MNE)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>02</day><month>08</month><year>2011</year></pub-date><volume>02</volume><issue>03</issue><fpage>300</fpage><lpage>304</lpage><history><date date-type="received"><day>April</day>	<month>19,</month>	<year>2011</year></date><date date-type="rev-recd"><day>May</day>	<month>19,</month>	<year>2011</year>	</date><date date-type="accepted"><day>May</day>	<month>26,</month>	<year>2011.</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this paper, the operation of the Double Fed Induction Generator (DFIG) in the range from synchronous speed down to sub-synchronous speeds is analyzed using the power-flow approach. The objective of this analysis is to determine a ceiling for the rating of the converter interfacing the rotor of the wind driven double fed induction generator (DFIG) to the grid. Sizing the converter is an important issue in determining the economic viability of using the DFIM as a generator at synchronous and sub-synchronous speeds in wind energy conversion systems. The size of the converter is proved to be less than 10% of the rated power of the DFIG, which is 40% to 67% lower than that estimated in previous publications.
 
</p></abstract><kwd-group><kwd>Double Fed Induction Generator</kwd><kwd> Converter Sizing</kwd><kwd> Cost Lowering</kwd><kwd> Wind Energy Conversion System</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The world community is very much concerned about “climate change” and specifically the global warming, which is mainly attributed to the increase of greenhouse gases (GHG) in the atmosphere. The GHG are mainly produced due to burning fossil fuels (oil derivatives, natural gas, and coal) and other organic matters (biomass) for power generation or other industrial purposes. The utilization of renewable energy resources (hydro, wind and solar) as alternatives to fossil fuels can mitigate the problem of GHG increase in the atmosphere.</p><p>Most of the hydro-energy resources all over the world, (except in some parts of the African continent), are being utilized for electric power generation. The second in row of renewable energy resources is the wind, which is considered the most promising and fastest growing energy resource worldwide.</p><p>The Global Wind Energy Council in Brussel, announced on February 2010, that the world’s wind power installed capacity grew by 31% in 2009, adding 37.5 GW to bring the total installed capacity of wind energy conversion systems up to 158 GW. The continued rapid growth in wind power capacity, despite the worldwide financial crisis and economic downturn, is testament to the inherent attractions of wind systems due to their environmental, economic, and technical merits. However, wind energy utilization has, beside the many merits, two main drawbacks, namely; the intermittent unpredictable nature of the wind resource, and the relatively large investment cost of the components of the wind energy conversion system (WECS).Of course, the nature of the wind could not be changed, but WECS could be connected to large power grids, and operate as fuel savers during the availability of reasonable wind speeds, while the fossil fuel fired power plants connected to the grid act as backup during the low wind speeds. At this point, the advantages of adjustable speed wind generators (ASG) should be mentioned, since this type of WECS can generate at all power levels and can extract the maximum amount of energy from the available wind speeds. The ASG are more cost effective than the fixed speed generators. They, also, have less mechanical stresses, improved power quality, and increased stability margin of the electric power grid.</p><p>The ASG can further be subdivided into two types, either those based on synchronous generators, or those based on doubly fed induction generators (DFIG). The DFIG based WECS dominate because of the significant reduction of the power rating and cost of the converter, the possible speed regulation for optimal utilization of energy, the possibility of controlling the reactive power, and finally the possibility of sub-synchronous , synchronous, and super-synchronous operation of the induction generator. Most, if not all the sold WECS during the last years, are DFIG-based systems. The market share of DFIG systems (75%) surpassed many times the other types of WECS.</p><p>In this paper, the size and consequently the cost of one of the main electrical components of the DFIG-based WECS, namely, the converter, is investigated. It is proved that the size of the converter (10% of rated DFIG power) is much less than estimated in previously published [<xref ref-type="bibr" rid="scirp.6564-ref1">1</xref>] papers (25% - 30%). The behavior of the DFIG at synchronous speed is also investigated.</p></sec><sec id="s2"><title>2. The Power Handled by the Converter in the Sub-Synchronous Range</title><p>The behavior of the electric power generating systems is usually governed by the demand side (electric load, grid requirements, etc.). The prime movers (fossil fuel fired turbines, hydro-turbines, diesel engines, etc.) are always responding to the needs of the power grid or loads. In the case of WECS, their behavior is governed mainly by the supply side, namely, the wind resource (wind speed and wind power). Thus it is more logical that any analysis of the performance of WECS starts from the prime mover side, i.e. wind turbine.</p><p>All manufactured variable speed wind turbines are pitch controlled type. Between the cut-in wind speed and the rated wind speed, the angular speed of the wind turbine and consequently the DFIG rotor speed changes to maintain an optimal tip speed ratio for maximum energy yield. Generally speaking, wind turbines are run along the so called maximum power point tracking [<xref ref-type="bibr" rid="scirp.6564-ref2">2</xref>] curve. <xref ref-type="fig" rid="fig1">Figure 1</xref> shows the most practically adopted shape for variation of the output mechanical power of the wind turbine versus the generator angular speed w. It shows a quadratic shape from the cut-in speed w<sub>c</sub>, to the rated speed w<sub>r</sub>, which correspond to the cut-in and rated wind speeds respectively.</p><p>The DFIG has its own synchronous speed w<sub>s</sub> corresponding to its number of poles and power frequency of the grid to which it is connected. The value of w<sub>r</sub> is usually 5% to 10% higher than w<sub>s</sub>.</p><p>It is well known [<xref ref-type="bibr" rid="scirp.6564-ref3">3</xref>] that the power flowing in the rotor of the DFIG has three components; namely, the mechanical power input to the rotor from the wind turbine P<sub>m</sub>, the electromagnetic power transferred from rotor to stator P<sub>g</sub>, and the slip power P<sub>s</sub> which is the electrical power transferred between the rotor and any external electrical source or load (e.g. converter) via the wound rotor slip rings. P<sub>s</sub> is partially consumed in rotor windings as copper losses and may be written as:</p><p><img src="14-6401081\ed24a1f2-7146-435a-98f7-b98167cd7c6c.jpg" />, where P<sub>c</sub> is power handled by converter and P<sub>cu2</sub> is rotor copper losses.</p><p>These components are inter-related as follows under any conditions:</p><p><img src="14-6401081\3cf87105-652a-40b8-b583-b864a6787383.jpg" /></p><p><img src="14-6401081\053a22b1-555c-46dd-99d1-727861147a95.jpg" /></p><disp-formula id="scirp.6564-formula35735"><graphic  xlink:href="14-6401081\35a96b0c-09d5-40f4-bb04-9cadf643acf4.jpg"  xlink:type="simple"/></disp-formula><p>where s is the rotor slip.</p><p>Neglecting the mechanical losses in the coupling, gearbox, and the rotor, then the mechanical power input to the rotor will be equal to the output power of the wind turbine. P<sub>m</sub><sub> </sub>= –P<sub>t</sub><sub></sub></p><p>The negative sign indicates that P<sub>t</sub> is the turbine output while P<sub>m</sub> is DFIG input In the speed range from w<sub>c</sub> to w<sub>r</sub> the mechanical power input to the DFIG at any angular speed can be expressed as:</p><p><img src="14-6401081\7b265d48-44b3-4769-b9db-028aedb91aa8.jpg" />k is a constant &#160;&#160;&#160;&#160;&#160;&#160; &#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;(1)</p><p>At the rotor angular speed w<sub>r</sub> corresponding to rated wind speed, the input mechanical power P<sub>mr</sub> is given as:</p><disp-formula id="scirp.6564-formula35736"><label>(2)</label><graphic position="anchor" xlink:href="14-6401081\9987178d-ba46-4cb3-8429-ed1f15406ded.jpg"  xlink:type="simple"/></disp-formula><p>From Equations (1) and (2) and considering:</p><p><img src="14-6401081\cc07f510-7827-49fa-9de2-1efa6b490604.jpg" /></p><p><img src="14-6401081\4c74555e-c0aa-4f13-821c-5a0bb119ae91.jpg" /></p><p><img src="14-6401081\9a85c5ba-3039-4139-98b6-29bd1f07ece6.jpg" /></p><p>the input mechanical power to the rotor of DFIG can be expressed as:</p><disp-formula id="scirp.6564-formula35737"><label>(3)</label><graphic position="anchor" xlink:href="14-6401081\c062b4ef-e26f-435b-b741-9dce528cc045.jpg"  xlink:type="simple"/></disp-formula><p>where s<sub>r</sub> and s<sub>c</sub> are the rotor slips corresponding to the rated and cut-in rotor angular speed respectively.</p><p>Since the amount of mechanical power converted to electrical power by the DFIG could not exceed the output power of the wind turbine, therefore, the slip power P<sub>s</sub> (which is approximately equal to the power handled by the converter), could not exceed , at any slip, the value given by the following Equation:</p><disp-formula id="scirp.6564-formula35738"><label>(4)</label><graphic position="anchor" xlink:href="14-6401081\577b468e-a003-4e5e-88af-654923428723.jpg"  xlink:type="simple"/></disp-formula><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows the variation of the per unit values of P<sub>m</sub>, P<sub>g</sub>, and P<sub>s</sub> as functions of the slip s in the range from cut-in to the synchronous rotor speed for an assumed practical value of s<sub>c</sub><sub> </sub>= 0.5 Also, the variation of the per unit value of P<sub>s</sub> versus the slip s is shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>, in enlarged scale. It is clear from <xref ref-type="fig" rid="fig3">Figure 3</xref> that there exists a slip s<sub>max</sub> at which the magnitude of the slip power has a maximum value. This value of slip is determined by equating the derivative of P<sub>s</sub> to zero, i.e. dP<sub>s</sub>/ds =0.</p><p>Differentiating Equation (4) and, equating the derivative to zero, and manipulating gives the following equation:</p><disp-formula id="scirp.6564-formula35739"><label>(5)</label><graphic position="anchor" xlink:href="14-6401081\981086f5-03e3-42be-9117-a5d230543428.jpg"  xlink:type="simple"/></disp-formula><p>The three roots of Equation (5) are:</p><p><img src="14-6401081\ed43f2de-7581-4457-8ff4-b898720639d5.jpg" />and&#160; <img src="14-6401081\f474fc18-13fa-4585-bbe6-92e9d257f2f5.jpg" /><sub></sub></p><p>The only valid root which lies between the cut-in and rated speeds is:</p><disp-formula id="scirp.6564-formula35740"><label>(6)</label><graphic position="anchor" xlink:href="14-6401081\c9133a74-91de-4396-a308-1fa81ae50cce.jpg"  xlink:type="simple"/></disp-formula><p>In practice the rated angular speed of the wind turbine ranges from 1.5 - 2.5 the cut in speed (w<sub>r</sub> = 1.5 to 2.5 w<sub>c</sub>).</p><p>Knowing that the rated speed is 5% to 10% higher than the synchronous speed of the DFIG, then the practical range of s<sub>c</sub> is between 0.35 and 0.6. Therefore, the slip power P<sub>s</sub>, (or approximately the power handled by the converter P<sub>c</sub><sub> </sub>= P<sub>s</sub><sub> </sub>&#177; Pc<sub>u2</sub>) could not exceed the value given in Equation (7):</p><disp-formula id="scirp.6564-formula35741"><label>(7)</label><graphic position="anchor" xlink:href="14-6401081\6a431aac-4ea6-48aa-8888-c720f586f79c.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.6564-formula35742"><label>(8)</label><graphic position="anchor" xlink:href="14-6401081\89377afd-830a-4bc2-ba6e-cbaebb048a77.jpg"  xlink:type="simple"/></disp-formula><p>The per unit maximum power handled by the converter is shown in <xref ref-type="fig" rid="fig4">Figure 4</xref> as function of the cut-in slip s<sub>c</sub> within the practical range of s<sub>c</sub> = 0.35 to 0.6. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows that the power handled by the converter ranges between 3.6% and 9.68% of the DFIG rated mechanical power, which is slightly less than the rated air gap power and consequently the rated output of the DFIG. The lower the value of s<sub>c</sub><sub> </sub>(the larger the value of the cut-in angular speed), the smaller will be the size of the converter. The value of s<sub>c</sub><sub> </sub>= 0.5 is a very common practice, i.e. the rated speed is approximately double the cut-in speed, and the corresponding converter size will not exceed 7.5% of the DFIG rated power. Since the cost of converter depends mainly on its rating in approximately linear relation, then when properly selecting the converter its cost will be reduced by 40% to 67% of that estimated in previous publications [<xref ref-type="bibr" rid="scirp.6564-ref1">1</xref>]. For the 1.5 MW to 3 MW size</p><p>WECS, the cost of the power converter range between 6.4% and 12.5% of the total WECS components cost. Therefore the proper selection of the DFIG power converter size will reduce the total system cost from 2.5% to 8%.</p></sec><sec id="s3"><title>3. The Power Handled by the Converter at Synchronous speed</title><p>The analysis in Section 2 of this paper, applies to the operation of DFIG from the cut-in speed up to just before the synchronous speed i.e. s<sub>c</sub><sub> </sub>&#163; s &lt; 0. This section is devoted to the operation of the DFIG at synchronous speed i.e. s = 0, where the DFIG will operate as a synchronous generator.</p><p>The rated power of the DFIG is calculated during the design phase as being the machine output when the rotor is short circuited. It could be easily proved that [<xref ref-type="bibr" rid="scirp.6564-ref3">3</xref>]:</p><disp-formula id="scirp.6564-formula35743"><label>(9)</label><graphic position="anchor" xlink:href="14-6401081\3d13b00a-4c3d-4719-93ed-007deee8814e.jpg"  xlink:type="simple"/></disp-formula><p>where P<sub>gr</sub><sub> </sub>= rated air gap power = rated output power (neglecting the stator losses)</p><p>m = number of phases of the DFIG</p><p><img src="14-6401081\55f03d68-cb6b-4072-953e-77a2af96a354.jpg" />rotor induced voltage&#160; at stand still</p><p><img src="14-6401081\dda1f834-4359-4100-89f2-b75fedabeb45.jpg" />rotor resistance</p><p><img src="14-6401081\d9536519-fcc1-4102-9b04-9f031c00f1ab.jpg" />= ratio of stand-still rotor leakage reactance to the rotor resistance</p><disp-formula id="scirp.6564-formula35744"><label>(10)</label><graphic position="anchor" xlink:href="14-6401081\036d141c-1542-432a-a8d6-cf6ede88fcba.jpg"  xlink:type="simple"/></disp-formula><p>From Equations (2) and (10), the input mechanical power at any slip s can be expressed as:</p><disp-formula id="scirp.6564-formula35745"><label>(11)</label><graphic position="anchor" xlink:href="14-6401081\ea25116f-dd58-4392-b4a0-fcd0168cdabb.jpg"  xlink:type="simple"/></disp-formula><p>At synchronous speed i.e. s = 0</p><disp-formula id="scirp.6564-formula35746"><label>(12)</label><graphic position="anchor" xlink:href="14-6401081\3b59d4d6-1a33-45f7-a165-c0c1c2bf9135.jpg"  xlink:type="simple"/></disp-formula><p>From the DFIG rotor side, following the rotor power flow approach as given in ref. [<xref ref-type="bibr" rid="scirp.6564-ref3">3</xref>], maximum air gap power transferred from the rotor to the stator of the DFIG at any slip s is expressed as</p><disp-formula id="scirp.6564-formula35747"><label>(13)</label><graphic position="anchor" xlink:href="14-6401081\6e4b430f-9e7a-4df2-967d-afbb918eae0e.jpg"  xlink:type="simple"/></disp-formula><p>where a is the ratio of the converter output voltage to the stand-still rotor induced voltage.</p><p>P<sub>gm</sub> is a continuous function of the slip from the sub-synchronous to the super-synchronous range, therefore at synchronous speed the value of P<sub>g</sub> at s = 0 can be expressed as</p><disp-formula id="scirp.6564-formula35748"><label>(14)</label><graphic position="anchor" xlink:href="14-6401081\5e06fbe2-3ab3-44f8-879b-71211c49e0de.jpg"  xlink:type="simple"/></disp-formula><p>The mechanical power input to the rotor, if the mechanical losses are neglected, will be converted to electrical power transferred to the stator through the air gap. Equating P<sub>m</sub> and P<sub>g</sub> at s = 0 from Equations (12) and (14), the following expression for a can be obtained</p><disp-formula id="scirp.6564-formula35749"><label>(15)</label><graphic position="anchor" xlink:href="14-6401081\32e6151e-a7f2-4ec4-9117-230b8079d32f.jpg"  xlink:type="simple"/></disp-formula><p>Therefore the value of the d.c. voltage output of the converter V<sub>c,</sub><sub> </sub>that keeps the DFIG converting all its mechanical input power into electrical power is given as :</p><disp-formula id="scirp.6564-formula35750"><label>(16)</label><graphic position="anchor" xlink:href="14-6401081\eabd62ed-d182-4d2e-a47a-4a5deaec9b68.jpg"  xlink:type="simple"/></disp-formula><p>The variation of a<sub> </sub>at s = 0 with the cut-in speed at a value of rated slip s<sub>r</sub><sub> </sub>= –0.05 is shown in <xref ref-type="fig" rid="fig5">Figure 5</xref> for different values of b. It is clear from <xref ref-type="fig" rid="fig5">Figure 5</xref> that the d.c. voltage output of the converter increases with the increase of the cutin slip. Thus the higher the value of b, the lower will be the value of a. Practically, the value of b for large DFIG is in the range from 8 to 10, and the cut-in slip is around the value of 0.5. Therefore, the d.c. voltage applied to the rotor circuit of the DFIG at synchronous speed will range between 3.4% - 3.6% of the rotor induced voltage of stand-still.</p><p>The power handled by the converter and at the same time consumed in the rotor circuit, is a very important parameter when assessing the performance of the DFIG operating as a synchronous machine</p><disp-formula id="scirp.6564-formula35751"><label>(17)</label><graphic position="anchor" xlink:href="14-6401081\c60358b1-c01c-4f2d-892c-ec2d86b192cb.jpg"  xlink:type="simple"/></disp-formula><p>From Equations (10), (15) and (16), the per unit value of the power handled by the converter (or consumed in the rotor circuit) can be expressed as:</p><disp-formula id="scirp.6564-formula35752"><label>(18)</label><graphic position="anchor" xlink:href="14-6401081\72ee5407-05fc-4874-b91c-3735ef06feff.jpg"  xlink:type="simple"/></disp-formula><p>where,</p><p><img src="14-6401081\d054d1fe-b692-4cdc-9abc-657f405d8458.jpg" /></p><p><img src="14-6401081\c75c35de-6c82-4792-b277-9f879ad4a0d7.jpg" /></p><p><xref ref-type="fig" rid="fig6">Figure 6</xref> shows the variation of the converter per-unit power with the cut-in speed for different values of <img src="14-6401081\a72237b2-e357-4c0c-8322-767ce592cba8.jpg" />. This power ranges between 2.8% and 3% of the rated value within the practical ranges of <img src="14-6401081\55fe3f29-06d0-4f42-896d-8b6aa8b77265.jpg" />(8 – 10) and s<sub>c</sub><sub> </sub>= 0.5. This power is equivalent to the power of the exciter of a synchronous machine. <img src="14-6401081\211c4283-a8e2-4722-866e-5d4799812d4e.jpg" /></p></sec><sec id="s4"><title>4. Conclusions</title><p>Operating the DFIM as a generator at synchronous speed is discussed. The magnitude of the rotor applied voltage essential for converting the mechanical output of the wind turbine into electrical power at synchronous speed is derived. Also, equations for the power handled by the converter at synchronous and sub-synchronous speeds are derived. These equations proved that the size of the converter is less than 10% of rated DFIG power, which is 40% to 67% lower than the estimated size in previous publications. This conclusion is in favor of deployment of DFIG as generator at synchronous and sub-synchronous speeds due to its lower cost when compared to conventional synchronous generators that need full power stator converters for power conditioning. Another advantage is its better efficiency, since more energy can be captured from the available wind.</p><p>Since the cost of converter depends mainly on its rating in approximately linear relation, then when properly selecting the converter its cost will be reduced by 40% to 67%. For the 1.5 MW to 3 MW size WECS, the cost of the power converter range between 6.4% and 12.5% of the total WECS components cost. Therefore the proper selection of the DFIG power converter size will reduce the total system cost from 2.5% to 8%. This cost reduction ensures the economic viability of WECS based on doubly fed induction generators (DFIG).</p><p>The results obtained in this paper could be very helpful for the designer of WECS by selecting the proper size of the converter.</p></sec><sec id="s5"><title>REFERENCES</title></sec><sec id="s6"><title>List of Symbols</title><p>P<sub>s</sub> slip power</p><p>P<sub>c</sub> converter power</p><p>P<sub>m</sub> mechanical power</p><p>P<sub>g</sub> air gap power</p><p>P<sub>cu</sub><sub>2</sub> rotor copper losses</p><p>V<sub>c</sub> converter output voltage</p><p>I<sub>c</sub> converter (rotor) current</p><p>E<sub>20</sub> induced voltage rotor at stand still</p><p>R<sub>2</sub> rotor resistance</p><p>s slip</p><p>s<sub>max</sub> slip at which slip power is maximum</p><p>w rotor angular speed</p><p>α ratio of converter to standstill rotor induced voltage</p><p>β ratio of standstill rotor leakage reactance to rotor resistance</p></sec><sec id="s7"><title>Subscripts</title><p>c cut in values</p><p>r rated values</p><p>p.u. per unit values</p></sec></body><back><ref-list><title>References</title><ref id="scirp.6564-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">M. A. Saleh and M. N. Eskander, “Sub-Synchronous Range of Operation for a Wind Driven Double-Fed Induction Generator,” Journal of Power Electronics, Vol. 10, No. 1, January 2010.</mixed-citation></ref><ref id="scirp.6564-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">D. Saidani, O. Hasnaoui and R. Dhifaoui, “Control of Double Fed Induction Generator for Wind Conversion System,” International Journal of Sciences and Techniques of Automatic Control &amp; Computer Engineering, Vol. 2, No. 2, December 2008, pp. 710-721.</mixed-citation></ref><ref id="scirp.6564-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">J. Hu and Y. He, “Reinforced Control and Operation of DFIG-Based Wind Power Generation System under Unbalanced Grid Voltage Conditions,” IEEE Transactions on Energy Conversion, Vol. 24, No. 4, December 2009, pp. 905-915. doi:10.1109/TEC.2008.2001434</mixed-citation></ref></ref-list></back></article>