<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AMPC</journal-id><journal-title-group><journal-title>Advances in Materials Physics and Chemistry</journal-title></journal-title-group><issn pub-type="epub">2162-531X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ampc.2015.511044</article-id><article-id pub-id-type="publisher-id">AMPC-60907</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Molecular Orientation Effect of Heat-Sealed PP Film on Peel Strength and Structure
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>azushi</surname><given-names>Yamada</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ken</surname><given-names>Miyata</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Reiichi</surname><given-names>Konishi</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kiyomi</surname><given-names>Okada</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tetsuya</surname><given-names>Tsujii</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Kyoto Institute of Technology, Kyoto, Japan</addr-line></aff><aff id="aff2"><addr-line>Yamagata University, Yamagata, Japan</addr-line></aff><aff id="aff3"><addr-line>Nakamoto Packs Co., Ltd., Osaka, Japan</addr-line></aff><aff id="aff4"><addr-line>PerkinElmer Japan Co., Ltd., Osaka, Japan</addr-line></aff><pub-date pub-type="epub"><day>05</day><month>11</month><year>2015</year></pub-date><volume>05</volume><issue>11</issue><fpage>439</fpage><lpage>446</lpage><history><date date-type="received"><day>22</day>	<month>September</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>2</month>	<year>November</year>	</date><date date-type="accepted"><day>5</day>	<month>November</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Heat sealing properties are optimized by controlling temperature, pressure and dwell time, while film strength depends on the drawn ratio and the molecular orientation of the film. However, heat seal strength of polymer films with high drawn ratio shows lower peel strength, because the adhesion of films needs a higher heat sealing energy for molecular orientation relaxation at heat sealing. In the present study, polypropylene films with a drawn ratio of 1.0&#215;, 1.5&#215;, and 2.5&#215; are heat sealed by using the heat sealing technique. The heat sealing condition is set to heat sealing time 1.0 s, sealing pressure 0.2 MPa, and heat sealing temperature 145&#176;C. The effect of drawn ratio and stabilization temperature of PP films for peel strength are investigated using T-Peel test, DSC, FT-IR, and Raman spectroscopy. As a result, it is found that the peel strength is decreased with increasing the drawn ratio and stabilization temperature of PP films. The difference of ?H and melting point from the result of DSC measurement are exhibited for 1.5&#215; drawn ratio film as compared with 2.5&#215; one. In addition, FT-IR imaging and Raman line mapping reveal the influence and variation of high order structure for heat sealed parts of the drawn PP films.
 
</p></abstract><kwd-group><kwd>Uniaxially-Extended Polypropylene</kwd><kwd> Molecular Orientation</kwd><kwd> Heat Sealing</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>In recent years, plastic bags with heat-sealing are widely used in food packages, such as snack, retort pouch, frozen food, and so on. Heat seal technology is a very important technique for packaging industries because of keeping a long shelf life for food. Basically, there are two typical films, which are generally used, including laminated films and homo films. Heat seal is carried out by fusing the polymers through the application of heat and pressure. The initial pressure makes closely contact with both of film surfaces. Then adhesion is promoted by applying heat and pressure from the outside of films. The important factors to obtain great heat seal properties include heat sealing temperature, heat seal pressure, heat seal time and dwell time for a cool down after heat sealing. Many researchers have investigated about heat sealing time, temperature, and pressure to evaluate the mechanical properties of heat sealed parts of plastic bags [<xref ref-type="bibr" rid="scirp.60907-ref1">1</xref>] -[<xref ref-type="bibr" rid="scirp.60907-ref9">9</xref>] .</p><p>On the other hand, film strength depends on the drawn ratio and molecular orientation of the film. The packaging film with high drawn ratio can be generally used for plastic bags which are required for high tensile strength, whereas the plastic film with a low drawn ratio can be made available for sealant layer, that is, OPP/ CPP laminated film. However, to use chemical adhesion bond for laminated films is undesirable from a viewpoint of environmental load, while thermal laminated films or homo films are desirable as plastic bags in future. The heat sealing ability of higher molecular orientation films is poor due to loss of the heat sealing energy for the relaxation of oriented molecules in polymer films. Accordingly, it is very important to understand the relationship between heat sealing conditions, molecular orientation, higher order structure, stabilization temperature in polymer films in order to evaluate the difference of mechanical properties in heat sealed parts.</p><p>In this research, we use homo-polymer film specimens with the different drawn ratio in order to evaluate the effect of molecular orientation on heat sealed properties. The films are heat sealed with heat bar sealing machine at heat sealing condition, which is heat sealing time 1.0 s, heat sealing pressure 0.2 MPa and heat sealing temperature 145˚C. The difference of higher order structure of the films is discussed on the basis of results of micro-Raman spectroscopy, FT-IR spectroscopy, DSC and tensile test.</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Materials</title><p>In this study, cast polypropylene (CPP) film (TOYOBO, PYLEN FILM-CT, P1011, Japan) was used as a base film. This CPP film was unidirectionally drawn at 1.0, 1.5, 2.5 times by uniaxial drawn machine (Nakamoto Packs Co., Ltd., Japan). At that time, these films were annealed at 80˚C, 100˚C, 120˚C to stabilize molecular orientation and drawn film. The drawn film conditions then will be referred as 1.0&#215;, 1.5&#215;, and 2.5&#215;, respectively.</p></sec><sec id="s2_2"><title>2.2. Heat Sealing</title><p><xref ref-type="fig" rid="fig1">Figure 1</xref> shows a schematic diagram of heat sealing method in this experiment. The uniaxial drawn and un- drawn films were placed in a bar type heat-sealing machine (Heat seal Tester, Sangyo Co., Ltd, Japan). The heat seal pressure was kept constantly at 0.2 MPa. The heat sealing time was 1.0 second. The heat sealing temperature was set to 145˚C.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Schematic illustration of heat sealing process</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x7.png"/></fig></sec><sec id="s2_3"><title>2.3. Peel Test</title><p>In order to examine the mechanical properties of the heat sealed part, a T-peel test was carried out with test pieces of 15 mm wide and 100 mm long. A schematic draw of the heat sealed specimen is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The peel test was performed at 300 mm/min by using an INSTRON universal testing machine (INSTRON 4466) at 20˚C. The span length was 50 mm.</p></sec><sec id="s2_4"><title>2.4. DSC Measurement</title><p>To examine the thermal properties of drawn sample films, a Differential Scanning Calorimeter (DSC) (Perkin-Elmer DSC, Pyris1) was utilized in the range of 40˚C to 250˚C at a heating rate of 20˚C/min under a nitrogen gas purge. The temperature and heat of transition obtained by the instrument were calibrated with indium and zinc standards before the measurements.</p></sec><sec id="s2_5"><title>2.5. Microscopic FT-IR Measurement</title><p>Heat sealed part of specimens were mapping by microscopic FT-IR (Frontier-Spotlight 400: Perkin Elmer, Japan) to evaluate the crystallinity and the orientation of heat sealed parts with and without heat sealing. Mapping mode was transmittance imaging method. Wave resolution was 4 cm<sup>−1</sup> with 2 scans. Pixel size was set to 25 μm.</p></sec><sec id="s2_6"><title>2.6. Microscopic Raman Spectroscopy</title><p>Raman spectra have been measured with the micro-Raman backscattering geometry. The Raman spectra were excited with the linearly polarized 633 nm line of He-Ne laser (LabRAM HR-800: HORIBA Co., Ltd., Japan). The excitation beam was directed to the sample compartment of a properly modulated metallurgical microscope (Olympus BX-41). The microscope was used for the delivery of the excitation laser beam on the sample and the collection of the backscattered light through a beam splitter with objective lens adapted to the aperture of the microscope. Exposed time was set to1.0 s. The number of scan was set to 5 times.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Effect of Stabilization Temperature of Each Drawn Film on Peel Strength</title><p><xref ref-type="fig" rid="fig3">Figure 3</xref> shows the peel strength of drawn film specimens at various stabilization temperatures. Peel strength of cast PP film was about 10 N. All of peel strengths for the drawn films indicated lower than that of cast PP film. The peel strength was decreased with increasing the drawn ratio for the PP film, while the peel strength was decreased with increasing the stabilization temperature for 1.0&#215; and 2.5&#215; drawn films although the peel strength of 1.5&#215; drawn film was slightly increased with increasing the stabilization temperature. The peel strength for 1.5&#215; drawn film showed around 3 N/15mm, while the peel strength for 2.5&#215; drawn film showed about only 1</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Schematic illustration of a specimen for peel test</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x8.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Peel strength of drawn film specimens for various stabilization temperatures at a heat sealed temperature of 145˚C</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x9.png"/></fig><p>N/15mm, and the strength reduced to approximately 30%. This is caused by the high molecular orientation degree in PP film as compared with low drawn ratio films such as 1.0&#215; and 1.5&#215;. As a result, it was hard to heat seal for 2.5&#215; drawn film. Thus, it is considered that there is a linear relationship between drawn ratio and peel strength, that is, depending on the orientation degree of PP molecules in the films.</p></sec><sec id="s3_2"><title>3.2. DSC Measurement</title><p>We tried to perform DSC measurement in order to evaluate the change in crystallinity of higher order structure at heat sealed part of the PP drawn films. <xref ref-type="fig" rid="fig4">Figure 4</xref>(a) and <xref ref-type="fig" rid="fig4">Figure 4</xref>(b) shows the typically DSC curves of CPP film and 2.5&#215; drawn PP film at 145˚C heat sealing temperature, respectively. Melting temperature and melting enthalpy (ΔH) value of the 1st and the 2nd heating thermogram of CPP film are similar, while melting point of the 1st heating thermogram of 2.5&#215; drawn film exhibited higher value as compared with the 2nd one. This difference depends on the drawn ratio of PP film, which influenced on differences in the molecular orientation of PP films. ΔH values of the films and heat sealed films at each heat sealing condition are shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. It was found that ΔH of non-heat sealed film was lower than heat sealed part due to a higher crystallinity of the heat sealed part as compared with the non-heat sealed part. In addition, ΔH of higher drawn ratio was lower than that of lower drawn ratio. It was attributed to the crystallization of the film after heat sealed. It can be considered that ΔH of higher drawn ratio film becomes low due to the energy waste to make it relaxation of the molecular orientation in PP films. Accordingly, these results will support the change in the secondary order structure of PP films. However, in the results of DSC measurement, it is very difficult to obtain the precise and information on secondary structure change in the edge area of heat sealed part. Hence, we applied the micro FT-IR mapping for heat sealed edge part of PP film for better understanding.</p></sec><sec id="s3_3"><title>3.3. Microscopic FT-IR Measurement</title><p><xref ref-type="fig" rid="fig6">Figure 6</xref> shows a typical FT-IR spectrum of PP film. Generally, the 998 cm<sup>−1</sup> and 841 cm<sup>−1</sup> bands are associated with long repeating monomer units in the crystalline 3<sub>1</sub> helix of PP. The short helix segments are associated with the 972 cm<sup>−1</sup> band of the FT-IR spectrum. There is a linear correlation between the intensities of the 998 cm<sup>−1</sup> and 841 cm<sup>−1</sup> bands and the density of PP as a measure of its crystallinity. Therefore, the crystallinity of PP can be determined by the ratio of the 998 cm<sup>−1</sup> and 972 cm<sup>−1</sup> absorption bands [<xref ref-type="bibr" rid="scirp.60907-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.60907-ref11">11</xref>] . <xref ref-type="fig" rid="fig7">Figure 7</xref> and <xref ref-type="fig" rid="fig8">Figure 8</xref> shows the CCD optical images and illustrate the FT-IR mapping images of PP film of heat sealed edge part. These mapping images were normalized at 972 cm<sup>−1</sup> and imaged the peak ratio for 998 cm<sup>−1</sup>/972cm<sup>−1</sup> as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref>. The left area corresponds to non-heat sealed part and the right area corresponds to heat sealed part in each image in <xref ref-type="fig" rid="fig8">Figure 8</xref>. From the result, light color corresponds to the higher crystallinity area. In non-heat sealed part, crystallinity was increased with increasing the stabilization temperature so that the color variation is consistent with the molecular orientation of PP film. Because drawn film could raise the creep relaxation without heat stabilization after drawing. Therefore, crystallinity of non-heat sealed part of PP film was decreased</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Typically DSC curves of (a) CPP film and (b) 2.5&#215; drawn film at 145˚C heat sealed temperature</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x10.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> ΔH of various heat sealed PP films at 145˚C for each stabilization temperature</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x11.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Typical FT-IR spectrum of PP films</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x12.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> CCD images for PP films with drawn ratio 1.5&#215; and 2.5&#215;, heat sealing temperature 145˚C</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x13.png"/></fig><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> IR mapping results for PP films with drawn ratio 1.5&#215; and 2.5&#215;, heat sealing temperature 145˚C</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x14.png"/></fig><p>with decreasing the stabilization temperature. On the other hand, similar tendency was shown in the heat sealed part of PP film, that is, crystallinity of heat sealed part was increased with increasing the stabilization temperature. However, in this case, it was seen that each crystallinity was lower as compared with non-heat sealed part. Because it is considered that the thermal energy of heat sealing is used for the relaxation of molecular orientation in PP films. As a result, the crystallinity of heat sealed part is lower than non-heat sealed part. In addition, the crystallinity of the edge part of heat sealing indicated the different tendency as compared with heat sealed and non-heat sealed part. It is very interesting and important phenomena of heat sealed films.</p></sec><sec id="s3_4"><title>3.4. Microscopic Raman Spectroscopy</title><p><xref ref-type="fig" rid="fig9">Figure 9</xref> presents the Raman spectra of PP film for each drawn film. After drawing, some peaks were suppressed, where is considered that these peaks are corresponding to molecular orientation in PP films. In this study, the peak ratio (I<sub>848</sub>/I<sub>818</sub>) was calculated in order to evaluate molecular orientation and/or crystallization changes near heat sealed edge part, and then the result was plotted in <xref ref-type="fig" rid="fig1">Figure 1</xref>0. The peak ratio of neat film was higher than heat sealed part in <xref ref-type="fig" rid="fig1">Figure 1</xref>0(a). The slope of strength change was observed in the interface area within 200 &#181;m. As the resolution and the pitch width of microscopic Raman spectroscopy are 1 &#181;m and 1 &#181;m respectively, it was found that the molecular orientation of PP films indicated the relaxation over an appreciable range of the slope gradually. It should be noted that when this slope is rapidly steep, stress concentration will arise at this edge part for tensile loading. In <xref ref-type="fig" rid="fig1">Figure 1</xref>0(b), the difference of Raman intensity was not indicated for each stabilization temperature, although the intensity at stabilization temperature 120˚C became slightly coarse because of the relaxation of molecular orientation by the heat sealing energy. However, the degree of relaxation for 2.5&#215; drawn film is very little as compared with 1.5&#215; drawn film, and the heat sealing energy of 1.0 s and 145˚C is insufficient to relax the molecular orientation of 2.5&#215; film. As a result, it is clarified that the peel strength of the film indicated the low value as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Typical Raman spectra of PP films with drawn ratio (a) 1.0&#215;; (b) 1.5&#215;; and (c) 2.5&#215;</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x15.png"/></fig><fig id="fig10"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Raman line-mapping results for heat sealed films with drawn ratio (a) 1.5&#215; and (b) 2.5&#215;</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-1510426x16.png"/></fig></sec></sec><sec id="s4"><title>4. Conclusion</title><p>In this investigation, we investigated the effect of molecular orientation at heat sealed part of drawn PP film using T-peel test, DSC, micro-FT-IR, and micro-Raman spectroscopy. From these results, it was found that the peel strength was decreased with increasing the drawn ratio and stabilization temperature of PP films. In addition, the difference of ∆H and melting point from the result of DSC measurement were exhibited for 1.5&#215; drawn ratio film as compared with 2.5&#215; one. The reason why higher drawn film indicates the poor peel strength and low thermal changes was revealed the molecular orientation and relaxation of PP films by using FT-IR imaging technique and micro-Raman spectroscopy. It was suggested that we could analyze the very small area and changes on the basis of the results of heat sealed part using micro-FT-IR and micro-Raman spectroscopy imaging, which applied for drawn PP films. In the future, it was expected that the effect of heat sealing temperature, heat sealing pressure, kinds of film, and film thickness would be investigated at the heat sealed edge part in order to get the better packaging products.</p></sec><sec id="s5"><title>Cite this paper</title><p>KazushiYamada,KenMiyata,ReiichiKonishi,KiyomiOkada,TetsuyaTsujii, (2015) Molecular Orientation Effect of Heat-Sealed PP Film on Peel Strength and Structure. Advances in Materials Physics and Chemistry,05,439-446. doi: 10.4236/ampc.2015.511044</p></sec><sec id="s6"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.60907-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Hashimoto, Y., Ishiaku, U.S., Leong, Y.W., Hamada, H. and Tsujii, T. (2006) Effect of Heat-Sealing Temperature on the Failure Criteria of Oriented Polypropylene/Cast Polypropylene Heat Seal. Polymer Engineering &amp; Science, 46, 205-214. http://dx.doi.org/10.1002/pen.20452</mixed-citation></ref><ref id="scirp.60907-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Aithani, D., Lockhart, H., Auras, R. and Tanprasert, K. (2006) Heat Sealing Measurement by an Innovative Technique. Packaging Technology and Science, 19, 245-257. http://dx.doi.org/10.1002/pts.728</mixed-citation></ref><ref id="scirp.60907-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Tetsuya, T., Hashimoto, Y., Ishiaku, U.S., Mizoguchi, M., Leong, Y.W. and Hamada, H. (2006) Effect of Heat-Sealing Temperature on the Properties of OPP/CPP Heat Seals. Part II. Crystal-linity and Thermomechanical Properties. Journal of Applied Polymer Science, 99, 513-519. http://dx.doi.org/10.1002/app.22443</mixed-citation></ref><ref id="scirp.60907-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Farris, S., Cozzolino, C.A., Introzzi, L. and Piergiovanni, L. (2009) Effects of Different Sealing Conditions on the Seal Strength of Polypropylene Films Coated with a Bio-Based Thin Layer. Packaging Technology and Science, 22, 359-369. http://dx.doi.org/10.1002/pts.861</mixed-citation></ref><ref id="scirp.60907-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Tetsuya, T., Ishiaku, U.S., Mizoguchi, M. and Hamada, H. (2005) The Effect of Heat Sealing Temperature on the Properties of OPP/CPP Heat Seal. I. Mechanical Properties. Journal of Applied Polymer Science, 97, 753-760. http://dx.doi.org/10.1002/app.21320</mixed-citation></ref><ref id="scirp.60907-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Yuan, C.S., Hassan, A., Ghazali, M.I.H. and Ismail, A.F. (2007) Heat Sealability of Laminated Films with LLDPE and LDPE as the Sealant Materials in Bar Sealing Application. Journal of Applied Polymer Science, 104, 3736-3745. http://dx.doi.org/10.1002/app.25863</mixed-citation></ref><ref id="scirp.60907-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Mihindukulasuriya, S.D. and Lim, L.-T. (2013) Heat Sealing of LLDPE Films: Heat Transfer Modeling with Liquid Presence at Film-Film Interface. Journal of Food Engineering, 116, 532-540. http://dx.doi.org/10.1016/j.jfoodeng.2012.12.027</mixed-citation></ref><ref id="scirp.60907-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Planes, E., Marouani, S. and Flandin, L. (2011) Optimizing the Heat Sealing Parameters of Multilayers Polymeric Films. Journal of Materials Science, 46, 5948-5958. http://dx.doi.org/10.1007/s10853-011-5550-4</mixed-citation></ref><ref id="scirp.60907-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Yamada, K., Miyata, K., Konishi, R., Tsujii, T. and Hashimoto, Y. (2015) Heat Seal Processing by Using Various Seal Bar Shape. AIP Conference Proceedings, 1664, 080002-1-080002-5. http://dx.doi.org/10.1063/1.4918458</mixed-citation></ref><ref id="scirp.60907-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Sadeghi, F., Ajji, A. and Carreau, P.J. (2007) Analysis of Row Nucleated Lamellar Morphology of Polypropylene Obtained from the Cast Film Process: Effect of Melt Rheology and Process Conditions. Polymer Engineering &amp; Science, 47, 1170-1178. http://dx.doi.org/10.1002/pen.20837</mixed-citation></ref><ref id="scirp.60907-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Cole, K.C., Perrin-Sarazin, F. and Dorval-Douville, G. (2005) Infrared Spectroscopic Characterization of Polymer and Clay Platelet Orientation in Blown Films Based on Polypropylene-Clay Nanocomposite. Macromolecular Symposia, 230, 1-10. http://dx.doi.org/10.1002/masy.200551135</mixed-citation></ref></ref-list></back></article>