<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">IJAMSC</journal-id><journal-title-group><journal-title>International Journal of Analytical Mass Spectrometry and Chromatography</journal-title></journal-title-group><issn pub-type="epub">2332-1768</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ijamsc.2015.33007</article-id><article-id pub-id-type="publisher-id">IJAMSC-59972</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  GC/MS: A Valid Tool for Soil Gas Hydrocarbons Speciation
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>aura</surname><given-names>Clerici</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Emanuela</surname><given-names>Mongini</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Pasquale</surname><given-names>Robles</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Pierluisa</surname><given-names>Dellavedova</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Maria</surname><given-names>Antonietta De Gregorio</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>U.O. Laboratorio di Milano, Sede Laboratoristica di via Juvara—Settore Laboratori—ARPA LOMBARDIA, Milano, Italia</addr-line></aff><aff id="aff2"><addr-line>Settore Laboratori—ARPA LOMBARDIA, Milano, Italia</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>a.degregorio@arpalombardia.it(MADG)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>01</day><month>09</month><year>2015</year></pub-date><volume>03</volume><issue>03</issue><fpage>54</fpage><lpage>62</lpage><history><date date-type="received"><day>3</day>	<month>July</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>25</month>	<year>September</year>	</date><date date-type="accepted"><day>28</day>	<month>September</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  This work describes an alternative method based on GC/MS technique with SCAN-ion approach for speciation of hydrocarbons contained in soil gas matrices and sampled on solid sorbent tubes (coconut shell charcoal).
 
</p></abstract><kwd-group><kwd>Hydrocarbons</kwd><kwd> Soil Gas Matrices</kwd><kwd> Solid Sorbent Tubes</kwd><kwd> Soil Gas</kwd><kwd> GC/MS</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Soil gas is defined as the atmosphere present in pore spaces of soil matrices [<xref ref-type="bibr" rid="scirp.59972-ref1">1</xref>] . These pores can undergo contamination phenomena, due to exposure to volatile pollutants. The latter can derive from different sources: contaminated soils and ground waters. Chemical-physical, geological and hydrogeological characteristics of each soil make its contamination highly compound- and site-specific. Therefore, one of the most recent aims of the analytical and environmental chemistry consists in hydrocarbons determination in soil gas matrices and their speciation.</p><p>Hydrocarbons represent a class of numerous and heterogeneous organic compounds ranging from linear, cyclic and branched saturated and unsaturated alkanes to aromatic and polycyclic ones. Each of these species is characterized by a peculiar value of toxicity and, as a consequence, their effect on the human health and environment is strongly different. More in detail, the speciation consists in the determination and quantification of hydrocarbons fractions in soil gas matrices.</p><p>In order to evaluate hydrocarbons carcinogenic effects, some specific target molecules have been identified: polycyclic aromatic hydrocarbons (PAHs), benzene, etc.</p><p>On the contrary, for toxic non-carcinogenic effects, specific hydrocarbons fractions are taken into account (e.g., in Italy for different environmental matrices C5-C8 aliphatic, C9-C12 aliphatic, C9-C10 aromatic, C11- C12 aromatic, C13-C18 aliphatic, C13-C22 aromatic and C19-C36 aliphatic have been identified) [<xref ref-type="bibr" rid="scirp.59972-ref2">2</xref>] .</p><p>If hydrocarbons speciation in contaminated soil and water matrices can be easily analyzed by the use of official analytical methods, the discussion about the more appropriate method for the analysis of soil gases collected on different supports is still open.</p><p>Among the official methods [<xref ref-type="bibr" rid="scirp.59972-ref3">3</xref>] -[<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] , one is based on hydrocarbon aromatic fraction quantification by extraction of characteristic ions and hydrocarbon aliphatic fraction quantification by total ion integration and subsequent subtraction of internal standard and target compounds peaks. This method is valid up to C12 aliphatic compounds and up to C10 aromatic compounds and is related to the use of canisters in the absence of any extraction solvent [<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] .</p><p>Another official method is useful for soil and water matrices [<xref ref-type="bibr" rid="scirp.59972-ref3">3</xref>] . It is based on the use of traditional detectors (FID and PID) that discriminate the different hydrocarbons fractions only on the base of the retention time and do not provide any information on the chemical species present in the samples.</p><p>Our needs, however, require not only the determination of C11-C12 aromatic hydrocarbons and C13-C18 aliphatic fractions (higher than C12), but also the use of CS<sub>2</sub> as an extraction solvent to elute hydrocarbons fraction from soil gas matrices sampled on solid sorbent tubes (coconut shell charcoal).</p><p>Therefore, in order to develop a unique, even empirical method for this purpose, in this work we demonstrate that gas-chromatography coupled with mass spectrometry is an effective technique for the speciation of hydrocarbons collected on chemical desorption solid sorbent tubes.</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Materials and Instruments</title><p>A standard solution containing all analytes (1000 &#181;g/mL for each analyte: n-pentane, 2-methylpentane, 2,2,4- trimethylpentane, n-nonane, n-butylcyclohexane, n-decane, 1,2,4-trimethylbenzene, naphthalene, butylbenzene, pentylbenzene, biphenyl, n-tetradecane, n-hexadecane, n-octadecane; Solution A) and an internal standard solution (ISTD, 2,5-dibrometoluene, 5000 &#181;g/mL) were purchased by CPAChem and used as received. They were bought as solutions in CS2. CS2 (99.9% purity low benzene) and solid sorbent tubes (coconut shell charcoal) for chemical desorption process were purchased by Sigma Aldrich. Real samples (SAMPLE 1-8), contaminated with aliphatic hydrocarbons, were sampled on solid sorbent tubes reported above.</p><p>All samples were analyzed by a GC/MS technique using an Agilent 7890A GC equipped with a 5975C inert MSD (mass spectrometer detector) with triple axis detector. The Agilent 7890A GC was interfaced with an Agilent 7683B Series Injector―Automatic Liquid Sampler. A Thermo TR5-MS (60 m &#215; 0.25 mm &#215; 1 &#181;m) column was employed.</p></sec><sec id="s2_2"><title>2.2. Certified Reference Materials (CRM) Preparation for Calibration Method</title><p>Calibration standards were prepared by dilution of Solution A with a diluted internal standard solution (d-ISTD, with a concentration of 10 μg/mL in CS<sub>2</sub>), as described in <xref ref-type="table" rid="table1">Table 1</xref>.</p><p>At each STD in the <xref ref-type="table" rid="table1">Table 1</xref> corresponds a calibration level (CAL LEV).</p><p>All the STD solutions reported in <xref ref-type="table" rid="table1">Table 1</xref> were injected in a GC/MS instrument interfaced with an automatic liquid sampler (Section 2.5).</p></sec><sec id="s2_3"><title>2.3. Fortified Materials Preparation for Method Validation (Precision and Recovery)</title><p>The availability of certified reference materials (CRM) is limited [<xref ref-type="bibr" rid="scirp.59972-ref6">6</xref>] . Moreover, because CRM are not commercially available for this kind of analyses (sample of solid sorbent tube coconut shell charcoal), fortified materials were prepared in-house. For this purpose, starting from Solution A, STD 8 and STD 5 were prepared as reported in <xref ref-type="table" rid="table1">Table 1</xref> but using pure CS<sub>2</sub> instead of diluted internal standard solution. Therefore, 100 μL of Solution A, STD 8 and STD 5 were spiked on 200 mg of coconut shell charcoal (solid sorbent tube).</p><p>This procedure was repeated ten times for each solution in order to obtain a series of ten samples for each concentration.</p></sec><sec id="s2_4"><title>2.4. Fortified Materials Analysis from Chemical Desorption of Sorbent Tubes</title><p>All materials reported in the Section 2.3 were extracted with 2 mL of d-ISTD (1 mL of d-ISTD for each 100 mg of carbon) [<xref ref-type="bibr" rid="scirp.59972-ref7">7</xref>] .</p></sec><sec id="s2_5"><title>2.5. GC/MS Analytical Procedure</title><p>All samples were processed using the following GC/MS conditions.</p><p>Oven Program: 40˚C for 8 min; then 4˚C/min to 100˚C for 0 min; then 15˚C/min to 320˚C for 9 min; then 40˚C/min to 330˚C for 1 min. Injection Volume: 1 &#181;L. SS Inlet: Mode splitless. Heater: 250˚C. Column: TR5- MS 60 m &#215; 250 &#181;m &#215; 1 &#181;m. Flow: 1.2 mL/min. MSD Parameters: MS Source 230˚C, MS Quadrupole 150˚C. SIM Parameter: characteristic ion Target and Qualifier for each VOC compounds. SCAN Parameter: Low Mass: 35.0 amu; High Mass: 350 amu. SIM and SCAN modes were simultaneously acquired.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><p>Starting from the data reported in the official methods [<xref ref-type="bibr" rid="scirp.59972-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] and on the base of our experience and technical requirements, an accurate mass spectra investigation of numerous chemical species representative of each hydrocarbons fraction (C5-C8 aliphatic, C9-C12 aliphatic, C9-C10 aromatic, C11-C12 aromatic, C13-C18 aliphatic) was carried out.</p><p><xref ref-type="table" rid="table2">Table 2</xref> reports standard markers and corresponding ions (m/z) used to quantify each hydrocarbons fraction, as well as the hydrocarbons range in terms of retention time.</p><p>All chromatograms were contemporary acquired by SIM―(selected ion monitoring) and SCAN-mode. SIM- mode analysis allows the quali-quantitative determination of target compounds, such as BTEX (benzene, toluene,</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Calibration standards (STD) preparation and hydrocarbons concentration in each fraction</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >STD and calibration level</th><th align="center" valign="middle" >STD prepation (μg/mL)</th><th align="center" valign="middle" >STD concentration (μg/mL) for each analyte</th></tr></thead><tr><td align="center" valign="middle" >STD 8 and CAL LEV8</td><td align="center" valign="middle" >100 &#181;L SolA/1mL diluted ISTD</td><td align="center" valign="middle" >100</td></tr><tr><td align="center" valign="middle" >STD 7 and CAL LEV7</td><td align="center" valign="middle" >500 &#181;L STD 8/1mL diluted ISTD</td><td align="center" valign="middle" >50</td></tr><tr><td align="center" valign="middle" >STD 6 and CAL LEV 6</td><td align="center" valign="middle" >200 &#181;L STD 8/1mL diluted ISTD</td><td align="center" valign="middle" >20</td></tr><tr><td align="center" valign="middle" >STD 5 and CAL LEV5</td><td align="center" valign="middle" >100 &#181;L STD 8/1mL diluted ISTD</td><td align="center" valign="middle" >10</td></tr><tr><td align="center" valign="middle" >STD 4 and CAL LEV4</td><td align="center" valign="middle" >500 &#181;L STD 5/1mL diluted ISTD</td><td align="center" valign="middle" >5</td></tr><tr><td align="center" valign="middle" >STD 3 and CAL LEV3</td><td align="center" valign="middle" >200 &#181;L STD 5/1mL diluted ISTD</td><td align="center" valign="middle" >2</td></tr><tr><td align="center" valign="middle" >STD 2 and CAL LEV2</td><td align="center" valign="middle" >100 &#181;L STD 5/1mL diluted ISTD</td><td align="center" valign="middle" >1</td></tr><tr><td align="center" valign="middle" >STD 1 and CAL LEV1</td><td align="center" valign="middle" >500 &#181;L STD 2/1mL diluted ISTD</td><td align="center" valign="middle" >0.5</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Target ions (m/z), standard markers and retention time window for each hydrocarbons fraction. <sup>*</sup>From Ref. [<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] </title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Hydrocarbons Fraction</th><th align="center" valign="middle" >m/z</th><th align="center" valign="middle" >Standard Marker</th><th align="center" valign="middle" >Beginning Marker</th><th align="center" valign="middle" >Ending Marker</th></tr></thead><tr><td align="center" valign="middle" >C5-C8 Aliphatic saturated, unsaturated, cyclic hydrocarbons</td><td align="center" valign="middle" >57 - 71 - 41</td><td align="center" valign="middle" >n-pentane 2-methylpentane 2,2,4-trimethylpentane</td><td align="center" valign="middle" >0.1 min before n-pentane</td><td align="center" valign="middle" >0.1 min before n-nonane</td></tr><tr><td align="center" valign="middle" >C9-C12 Aliphatic saturated, unsaturated, cyclic hydrocarbons</td><td align="center" valign="middle" >57 - 71 - 41</td><td align="center" valign="middle" >n-nonane n-butylcyclohexane n-decane n-dodecane</td><td align="center" valign="middle" >0.1 min before n-nonane</td><td align="center" valign="middle" >0.1 min before naphtalene</td></tr><tr><td align="center" valign="middle" >C9-C10 Aromatic</td><td align="center" valign="middle" >120 - 134<sup>*</sup></td><td align="center" valign="middle" >1,2,4-trimethylbenzene butylbenzene</td><td align="center" valign="middle" >0.1 min after o-xylene</td><td align="center" valign="middle" >0.1 min before naphtalene</td></tr><tr><td align="center" valign="middle" >C11-C12 Aromatic</td><td align="center" valign="middle" >148 - 154 - 162 - 115</td><td align="center" valign="middle" >Pentylbenzene biphenyl</td><td align="center" valign="middle" >0.1 min before pentylbenzene</td><td align="center" valign="middle" >0.1 min after biphenyl</td></tr><tr><td align="center" valign="middle" >C13-C18 Aliphatic saturated, unsaturated, cyclic hydrocarbons</td><td align="center" valign="middle" >57 - 71 - 41</td><td align="center" valign="middle" >n-tetradecane n-hexadecane n-octadecane</td><td align="center" valign="middle" >0.1 min after n-dodecane</td><td align="center" valign="middle" >0.1 min after n-octadecane</td></tr></tbody></table></table-wrap><p>ethylbenzene, xylenes), MTBE (methyl-ter-butyl-ether), halogenated VOC (volatile organic compounds), etc. SCAN-mode analysis permits the identification and determination of hydrocarbons fractions by characteristic ions extraction (SCAN-ion quantification) within the typical retention time of each fraction.</p><p>SCAN-ion approach allows achieving many benefits. Among them, the most important one consists in a correct and easy integration of more critical fractions: C5-C8 and C13-C18 aliphatic.</p><p>In fact, C5-C8 aliphatic fraction could be affect by the presence of solvent front (CS<sub>2</sub>), whereas column bleed, strictly related to the oven temperature increase, could have a negative effect on the C13-C18 aliphatic fraction determination, in particular at low concentration, causing an analytical sensitivity drop.</p><p>SCAN-ion approach, based on the characteristic ions extraction, improves analytical performances, as described in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><sec id="s3_1"><title>3.1. Initial Calibration</title><p>The relationship between detector response of each analyte and collective range concentration was calculated by the RRFs approach (Equation (1)):</p><disp-formula id="scirp.59972-formula819"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-1550042x6.png"  xlink:type="simple"/></disp-formula><p>where RRF = relative response factor, A<sub>x</sub><sub> </sub>= sum of ions areas of each fraction to be measured, C<sub>is </sub>= concentration of internal standard spiking mixture, &#181;g/mL, A<sub>is</sub>= area of the primary ion for the internal standard, C<sub>x</sub> = concentration of hydrocarbons fraction in the calibration standard, &#181;g/mL.</p><p>The calculated %RDS (Equation (2)) the RRF for each hydrocarbons fraction in the calibration method resulted to be less than 30%, as required by the technical acceptance criteria for initial calibration [<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] .</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> (A) (B) SCAN-mode acquired chromatograms and hydrocarbon fractions quantification using total ion integration; (C) (D) SCAN-mode acquired chromatograms and hydrocarbon fractions quantification using SCAN-ion approach by characteristic ions extraction (m/z 57, 71, 41)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-1550042x7.png"/></fig><disp-formula id="scirp.59972-formula820"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-1550042x8.png"  xlink:type="simple"/></disp-formula><p>where SD (RRF) = standard deviation of initial response factors for each fraction, RRF(mean) = mean of initial relative response factors for each fraction.</p><p>However, when these technical criteria were not satisfied, linear and nonlinear regressions were used, as for the C5-C8 aliphatic fraction (linear regression R<sup>2</sup> ≥ 0.98).</p><p>Moreover, following the recommendations reported in [<xref ref-type="bibr" rid="scirp.59972-ref8">8</xref>] , other technical acceptance criteria, were satisfied, as:</p><p>・ The RRT (Relative Retention Time) for each hydrocarbons fraction at each calibration level was within 0.06 RRT units of the mean RRT for the fraction;</p><p>・ The Retention Time (RT) shift of ISTD at each calibration level was within 20 s of the mean RT over the initial calibration range for ISTD;</p><p>・ The area response of the internal standard at each calibration level was within 40% of the mean area response over initial calibration range for ISTD.</p></sec><sec id="s3_2"><title>3.2. Precision, Recovery and Uncertainty</title><p>As described in Section 2.3, ten fortified materials at three different concentrations were prepared, in order to evaluate quality data of the method.</p><p>Tables 3-5 summarize mean of precision data, CV% and recovery% obtained for all fractions at three concentrations (&#181;g/mL) reported in the <xref ref-type="table" rid="table1">Table 1</xref>.</p><p>It is worth to notice that in all data reported in Tables 3-5 CV% and recovery% are in line with the technical acceptance criteria reported in the literature [<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] .</p><p>All data were analyzed by means of statistical tests: Shapiro-Wilk normality test and Dixon test for identify and reject outliers.</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Mean value, CV% and recovery% for each hydrocarbons fraction at concentration corresponding to STD 1 in <xref ref-type="table" rid="table1">Table 1</xref></title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Fractions</th><th align="center" valign="middle" >Mean</th><th align="center" valign="middle" >CV%</th><th align="center" valign="middle" >Recovery%</th></tr></thead><tr><td align="center" valign="middle" >C9-C12 Aliphatic</td><td align="center" valign="middle" >2.36</td><td align="center" valign="middle" >7.79</td><td align="center" valign="middle" >118</td></tr><tr><td align="center" valign="middle" >C9-C10 Aromatic</td><td align="center" valign="middle" >1.20</td><td align="center" valign="middle" >5.41</td><td align="center" valign="middle" >120</td></tr><tr><td align="center" valign="middle" >C11-C12 Aromatic</td><td align="center" valign="middle" >0.91</td><td align="center" valign="middle" >5.71</td><td align="center" valign="middle" >91</td></tr><tr><td align="center" valign="middle" >C13-C18 Aliphatic</td><td align="center" valign="middle" >1.81</td><td align="center" valign="middle" >4.80</td><td align="center" valign="middle" >120</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Mean value, CV% and recovery% for each hydrocarbons fraction at concentration corresponding to STD 4 in <xref ref-type="table" rid="table1">Table 1</xref></title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Fraction</th><th align="center" valign="middle" >Mean</th><th align="center" valign="middle" >CV%</th><th align="center" valign="middle" >Recovery%</th></tr></thead><tr><td align="center" valign="middle" >C5-C8 Aliphatic</td><td align="center" valign="middle" >19.42</td><td align="center" valign="middle" >13.03</td><td align="center" valign="middle" >129</td></tr><tr><td align="center" valign="middle" >C9-C12 Aliphatic</td><td align="center" valign="middle" >16.82</td><td align="center" valign="middle" >4.08</td><td align="center" valign="middle" >84</td></tr><tr><td align="center" valign="middle" >C9-C10 Aromatic</td><td align="center" valign="middle" >7.86</td><td align="center" valign="middle" >5.43</td><td align="center" valign="middle" >79</td></tr><tr><td align="center" valign="middle" >C11-C12 Aromatic</td><td align="center" valign="middle" >5.76</td><td align="center" valign="middle" >5.88</td><td align="center" valign="middle" >58</td></tr><tr><td align="center" valign="middle" >C13-C18 Aliphatic</td><td align="center" valign="middle" >12.77</td><td align="center" valign="middle" >5.23</td><td align="center" valign="middle" >85</td></tr></tbody></table></table-wrap><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> Mean value, CV% and recovery% for each hydrocarbons fraction at concentration corresponding to STD 7 in <xref ref-type="table" rid="table1">Table 1</xref></title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Fraction</th><th align="center" valign="middle" >Mean</th><th align="center" valign="middle" >CV%</th><th align="center" valign="middle" >Recovery%</th></tr></thead><tr><td align="center" valign="middle" >C5-C8 Aliphatic</td><td align="center" valign="middle" >201.15</td><td align="center" valign="middle" >4.09</td><td align="center" valign="middle" >134</td></tr><tr><td align="center" valign="middle" >C9-C12 Aliphatic</td><td align="center" valign="middle" >158.79</td><td align="center" valign="middle" >4.64</td><td align="center" valign="middle" >79</td></tr><tr><td align="center" valign="middle" >C9-C10 Aromatic</td><td align="center" valign="middle" >81.79</td><td align="center" valign="middle" >3.43</td><td align="center" valign="middle" >82</td></tr><tr><td align="center" valign="middle" >C11-C12 Aromatic</td><td align="center" valign="middle" >67.73</td><td align="center" valign="middle" >1.71</td><td align="center" valign="middle" >68</td></tr><tr><td align="center" valign="middle" >C13-C18 Aliphatic</td><td align="center" valign="middle" >131.29</td><td align="center" valign="middle" >6.80</td><td align="center" valign="middle" >88</td></tr></tbody></table></table-wrap><p>As an example, in <xref ref-type="fig" rid="fig2">Figure 2</xref> the distribution obtained for C13-C18 fraction at concentration values corresponding to STD 1 in <xref ref-type="table" rid="table1">Table 1</xref> is reported.</p><p>The LOQ of the present method for each hydrocarbons fraction was mathematically estimated multiplying the standard deviation values, obtained from fortified materials at concentration values corresponding to STD 1 (see <xref ref-type="table" rid="table1">Table 1</xref>), by 5 (<xref ref-type="table" rid="table6">Table 6</xref>).</p><p>Uncertainty was estimated by metrological approach calculating each component to the final uncertainty [<xref ref-type="bibr" rid="scirp.59972-ref9">9</xref>] . For all fractions the uncertainty value was estimated about &#177;60%.</p></sec></sec><sec id="s4"><title>4. Real Samples Analysis</title><p>Eight real samples collected on solid sorbent tubes (SAMPLE 1-8), contaminated with C5-C8 and C9-C12 aliphatic hydrocarbons fraction, were quantified by both the traditional TIC-SCAN method [<xref ref-type="bibr" rid="scirp.59972-ref5">5</xref>] and the present one (SCAN-ion), in order to prove the performances of our innovative analytical approach.</p><p>It is worth to notice that the results (<xref ref-type="table" rid="table7">Table 7</xref>, <xref ref-type="table" rid="table8">Table 8</xref> and Figures 3-6) obtained by the two methods are rather comparable and correlated with a mean difference that lower than 30%, which is included in the uncertainty.</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Normal distribution of C13-C18 fraction data</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-1550042x9.png"/></fig><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> Standard deviation (SD) and limit of quantification (LOQ) for all hydrocarbons fractions</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Fraction</th><th align="center" valign="middle" >SD</th><th align="center" valign="middle" >LOQ (&#181;g/mL = 100 mg Carbon)</th></tr></thead><tr><td align="center" valign="middle" >C5-C8 Aliphatic</td><td align="center" valign="middle" >2.53</td><td align="center" valign="middle" >12.66</td></tr><tr><td align="center" valign="middle" >C9-C12 Aliphatic</td><td align="center" valign="middle" >0.18</td><td align="center" valign="middle" >0.92</td></tr><tr><td align="center" valign="middle" >C9-C10 Aromatic</td><td align="center" valign="middle" >0.07</td><td align="center" valign="middle" >0.33</td></tr><tr><td align="center" valign="middle" >C11-C12 Aromatic</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >0.26</td></tr><tr><td align="center" valign="middle" >C13-C18 Aliphatic</td><td align="center" valign="middle" >0.09</td><td align="center" valign="middle" >0.43</td></tr></tbody></table></table-wrap><table-wrap id="table7" ><label><xref ref-type="table" rid="table7">Table 7</xref></label><caption><title> A comparasion between the C5-C8 aliphatic hydrocarbons fraction concentration of real samples quantified by TIC-scan and SCAN-ion approaches</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >SAMPLES</th><th align="center" valign="middle" >C5-C8 ALIPHATIC by TIC-scan concentration (&#181;g/mL = 100 mg Carbon)</th><th align="center" valign="middle" >C5-C8 ALIPHATIC by SCAN-ion concentration (&#181;g/mL = 100 mg Carbon)</th></tr></thead><tr><td align="center" valign="middle" >SAMPLE 1</td><td align="center" valign="middle" >51</td><td align="center" valign="middle" >65</td></tr><tr><td align="center" valign="middle" >SAMPLE 2</td><td align="center" valign="middle" >237</td><td align="center" valign="middle" >190</td></tr><tr><td align="center" valign="middle" >SAMPLE 3</td><td align="center" valign="middle" >79</td><td align="center" valign="middle" >61</td></tr><tr><td align="center" valign="middle" >SAMPLE 4</td><td align="center" valign="middle" >113</td><td align="center" valign="middle" >80</td></tr><tr><td align="center" valign="middle" >SAMPLE 5</td><td align="center" valign="middle" >133</td><td align="center" valign="middle" >88</td></tr><tr><td align="center" valign="middle" >SAMPLE 6</td><td align="center" valign="middle" >257</td><td align="center" valign="middle" >185</td></tr><tr><td align="center" valign="middle" >SAMPLE 7</td><td align="center" valign="middle" >108</td><td align="center" valign="middle" >82</td></tr><tr><td align="center" valign="middle" >SAMPLE 8</td><td align="center" valign="middle" >180</td><td align="center" valign="middle" >131</td></tr></tbody></table></table-wrap><table-wrap id="table8" ><label><xref ref-type="table" rid="table8">Table 8</xref></label><caption><title> A comparasion between the C9-C12 aliphatic hydrocarbons fraction concentration of real samples quantified by TIC-scan and SCAN-ion approaches</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >SAMPLES</th><th align="center" valign="middle" >C9-C12 ALIPHATIC by TIC-scan concentration (&#181;g/mL = 100 mg Carbon)</th><th align="center" valign="middle" >C9-C12 ALIPHATIC by SCAN-ion concentration (&#181;g/mL = 100 mg Carbon)</th></tr></thead><tr><td align="center" valign="middle" >SAMPLE 1</td><td align="center" valign="middle" >125</td><td align="center" valign="middle" >92</td></tr><tr><td align="center" valign="middle" >SAMPLE 2</td><td align="center" valign="middle" >90</td><td align="center" valign="middle" >71</td></tr><tr><td align="center" valign="middle" >SAMPLE 3</td><td align="center" valign="middle" >123</td><td align="center" valign="middle" >84</td></tr><tr><td align="center" valign="middle" >SAMPLE 4</td><td align="center" valign="middle" >138</td><td align="center" valign="middle" >118</td></tr><tr><td align="center" valign="middle" >SAMPLE 5</td><td align="center" valign="middle" >25</td><td align="center" valign="middle" >22</td></tr><tr><td align="center" valign="middle" >SAMPLE 6</td><td align="center" valign="middle" >157</td><td align="center" valign="middle" >107</td></tr><tr><td align="center" valign="middle" >SAMPLE 7</td><td align="center" valign="middle" >38</td><td align="center" valign="middle" >37</td></tr></tbody></table></table-wrap><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Trend of SCAN-ion vs TIC-scan for C5-C8 aliphatic hydrocarbons fraction</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-1550042x10.png"/></fig><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Correlation between data (<xref ref-type="table" rid="table7">Table 7</xref>) derived by TIC-scan and SCAN-ion approaches</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-1550042x11.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Trend of SCAN-ion vs TIC-scan for C9-C12 aliphatic hydrocarbons fraction</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-1550042x12.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Correlation between data (<xref ref-type="table" rid="table8">Table 8</xref>) derived by TIC-scan and SCAN-ion approaches</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-1550042x13.png"/></fig></sec><sec id="s5"><title>5. Conclusions</title><p>As an alternative to official methods, in this work an innovative empirical GC/MS method for hydrocarbons speciation in soil gas matrices was proposed.</p><p>It is based on the use of a mass spectrometer as the detector and on SCAN-ion acquisition approach that allows separating the different fractions and identifying the chemical species present in all fractions, permits the use of an extraction solvent (CS<sub>2</sub>) to elute hydrocarbons fraction from solid sorbent tubes (coconut shell charcoal) and extends the determination to hydrocarbons fraction up to C18.</p><p>Good performances in terms of precision, recovery and uncertainty were obtained.</p><p>The analyses of real samples provided promising results compared to those from traditional approaches. The simplicity and velocity of the method make it a good candidate for wide applications in routine work for analyses of soil gas matrices sampled on solid sorbent tubes.</p></sec><sec id="s6"><title>Cite this paper</title><p>LauraClerici,EmanuelaMongini,PasqualeRobles,PierluisaDellavedova,Maria Antonietta DeGregorio, (2015) GC/MS: A Valid Tool for Soil Gas Hydrocarbons Speciation. International Journal of Analytical Mass Spectrometry and Chromatography,03,54-62. doi: 10.4236/ijamsc.2015.33007</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.59972-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Mayer, C.L. (In Press) Guidance Document for Soil-Gas Surveying, Prepared under EPA EMSL-LV Contract n. 68033245. Lockheed Engineering and Sciences Company, Las Vegas.</mixed-citation></ref><ref id="scirp.59972-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Cambiaghi, M., Cogliati, N. and Maspero, M. (2009) Idrocarburi e analisi di rischio: problemi e interpretazioni. Acqua &amp; Aria, 5, 18-23.</mixed-citation></ref><ref id="scirp.59972-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Department of Environmental Protection (2004) Method for the Determination of Volatile Petroleum Hydrocarbons (VPH), Revision 1.1. Department of Environmental Protection, Massachusetts</mixed-citation></ref><ref id="scirp.59972-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Department of Environmental Protection (2004) Method for the Determination of Extractable Petroleum Hydrocarbons (EPH), Revision 1.1. Department of Environmental Protection, Massachusetts.</mixed-citation></ref><ref id="scirp.59972-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Department of Environmental Protection (2009) Method for Determination of Air-Phase Petroleum Hydrocarbon (APH), Final Revision 1. Department of Environmental Protection, Massachusetts.</mixed-citation></ref><ref id="scirp.59972-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">EURACHEM (1998) The Fitness for Purpose of Analytical Methods—A Laboratory Guide to Method Validation and Related Topics. EURACHEM Guide, 22.</mixed-citation></ref><ref id="scirp.59972-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">UNI EN 13649-2002. Emissioni da sorgente fissa—Determinazione della concentrazione in massa di singoli composti organici in forma gassosa. Metodo mediante carboni attivi e desorbimento con solvente; §7 Procedimento analitico, §§ 7.1. Desorbimento del campione.</mixed-citation></ref><ref id="scirp.59972-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">EPA (1999) Compendium Method TO-15.</mixed-citation></ref><ref id="scirp.59972-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">EURACHEM-CITAC Guide (2011) Quantifying Uncertainty in Analytical Measurement, Third Edition.</mixed-citation></ref></ref-list></back></article>