<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJAppS</journal-id><journal-title-group><journal-title>Open Journal of Applied Sciences</journal-title></journal-title-group><issn pub-type="epub">2165-3917</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojapps.2015.58048</article-id><article-id pub-id-type="publisher-id">OJAppS-59236</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject><subject> Computer Science&amp;Communications</subject><subject> Engineering</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  The Evaluation of Measurement Uncertainty and Its Application in the Vacuum Pressure Measurement
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ulin</surname><given-names>Zhou</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xin</surname><given-names>Quan</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tieniu</surname><given-names>Yang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>School of Mechanical and Electrical Engineering, Wuyi University, Jiangmen, China</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>wyuzyl@163.com(UZ)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>04</day><month>08</month><year>2015</year></pub-date><volume>05</volume><issue>08</issue><fpage>495</fpage><lpage>500</lpage><history><date date-type="received"><day>10</day>	<month>August</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>25</month>	<year>August</year>	</date><date date-type="accepted"><day>28</day>	<month>August</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In order to accurately measure the pressure and the pressure difference between two points in the vacuum chamber, a large number of experimental data were used to research the performance of the three capacitance diaphragm gauge and analysis the main influences of the uncertainly degree of pressure in the process. In this paper, three kind of uncertainty, such as the single uncertainty, the synthesis uncertainty and the expanded uncertainty of the three capacitance diaphragm gauges are introduced in detail in pressure measurement. The results show that the performance difference of capacitance diaphragm gauge can be very influential to the accuracy of the pressure difference measurement and the uncertainty of different pressure can be very influential to pressure measurement. That for accurately measuring pressure and pressure difference has certain reference significance.
 
</p></abstract><kwd-group><kwd>Capacitance Diaphragm Gauges</kwd><kwd> Pressure Measurement</kwd><kwd> Measurement Uncertainty</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The progress of science and technology depends on the development of microelectronics and semiconductor technology that the upgrading and renewing of equipment and technology of microelectronics and semiconductor consequently grow rapidly. This attracted some researchers to study on it. Regardless of from equipment research and development or technological parameters on the need to measure pressure in integrated circuit (IC) processing chamber.</p><p>Evaluation of uncertainty is widely used in the test, measurement and other fields of engineering research [<xref ref-type="bibr" rid="scirp.59236-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.59236-ref2">2</xref>] . Capacitance film gauges (CDGs) measuring the pressure have some advantages such as high accuracy, good linearity and measurement result has nothing to do with the gas composition and types so that it can be applied to measure pressure in IC processing chamber. Due to the difference in manufacture, using time and over-pressure environment that will cause the performance difference [<xref ref-type="bibr" rid="scirp.59236-ref3">3</xref>] . To study the pressure difference in vacuum chamber during dynamic gas flow when the inlet flow rate is low, differential pressure sometimes is only a fraction of Pa. Therefore, the uncertainty factors of capacitance film gauge are very important for the pressure measurement.</p><p>This paper based on ASME PTC 19.2-2010 “Pressure Measurement Instruments and Apparatus Supplement” of China as the standard for studying the uncertainty of pressure measurement. This experiment adopts three capacitance film gauges which come from INFICON Instruments Inc., USA and its range is 1333 Pa. Through the experiment, pressure difference between film gauges in measuring pressure is got. Various factors [<xref ref-type="bibr" rid="scirp.59236-ref4">4</xref>] which influence the uncertainty are analyzed and the results provide a base for measuring pressure or pressure differences.</p></sec><sec id="s2"><title>2. Experimental Apparatus</title><p>The experimental system mainly includes the gas intake system, pressure measurement system, extraction system. The height of the chamber is 320 mm while its inner diameter is 580 mm (capacity = 84.5 L) as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. And the vacuum chamber made of 304 stainless steel that is pumped by a high vacuum pumping system is composed of a turbo molecular pump with pumping speed 300 L∙s<sup>−1</sup> for N<sub>2</sub> backed by a 82 m<sup>3</sup>∙s<sup>−1</sup> roots pump. The chamber is extracted through a flapper valve of diameter 100 mm. At first, the vacuum chamber wall would suffer two hours’ baking (about 100 degrees Celsius) by a heating jacket, then, the chamber would be extracted for about four hours. It could be achieved that the pressure of the chamber was less than 2 &#180; 10<sup>−4</sup> Pa. Based on the static pressure boosting method, the overall leak rate of the chamber was 8.84 &#180; 10<sup>−6</sup> Pa∙m<sup>2</sup>∙s<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.59236-ref5">5</xref>] .</p><p>For this purpose, three capacitance diaphragm gauges (CGG1, CGG2, CGG3, zero pressure less than 4 &#180; 10<sup>−4 </sup>Pa) are flanged joint on the cavity wall as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The basic composition of chamber</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/8-2310471x6.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> CDGs locations</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/8-2310471x7.png"/></fig></sec><sec id="s3"><title>3. Experimental</title><sec id="s3_1"><title>3.1. Experimental Process</title><p>Experimental research on pressure in the range of 10 - 100 Pa, it is necessary to investigate pressure difference in static environment of the three film gauge. Setting the static pressure values such as 20 Pa, 30 Pa, 40 Pa, 50 Pa, 60 Pa, 70 Pa, 80 Pa, 90 Pa, 100 Pa and recording readings of the CDGs, to find out the difference between them. Specific process is as follows: firstly, increasing chamber pressure to over 100 Pa through the vent valve. Secondly, only starting the roots pump to make the pressure at setting value, stopping evacuating. Finally, Please wait until this date is stable and record data.</p><p>In the above experiment system, controlling strictly the influence of other experimental factors, such as, keeping the indoor temperature at 20˚C &#177; 0.2˚C and the humidity at 50% &#177; 2% RH, ensuring the Experiments occur in the condition that in absence of noise and vibration situation. In order to exclude specific situation, repeat the experiment 10 times.</p></sec><sec id="s3_2"><title>3.2. Experimental Results</title><p>The experimental data are dealt with error processing, and the conclusions from these are compared. For example, in terms of 20 Pa, the average measured data, the residual error of the CDG can be obtained, respectively. The average of residual error in 10 times test to obtain average residual error of every CDG at 20 Pa shown in <xref ref-type="table" rid="table1">Table 1</xref>. The data processing steps of other pressure are as same as the condition of static pressure 20 Pa, the results as shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><p><xref ref-type="table" rid="table1">Table 1</xref> shows the average residual error difference of CDGs, for examples, 1 - 2 means difference between CDG1 and CDG2, others like them. The hydrostatic pressure difference of CDGs is shown in <xref ref-type="table" rid="table2">Table 2</xref>.</p><p>The static pressure of chamber should be equal. <xref ref-type="table" rid="table2">Table 2</xref> shows that there are performance differences among CDGs, so the measurement results are corrected based on the pressure difference.</p></sec></sec><sec id="s4"><title>4. Uncertainty Calculation</title><sec id="s4_1"><title>4.1. Mathematical Model Established</title><p>The pressure measurement mathematical model of CDG is denoted from the simple relation.</p><disp-formula id="scirp.59236-formula1511"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/8-2310471x8.png"  xlink:type="simple"/></disp-formula><p>where P<sub>u</sub> (P<sub>a</sub>) is the Instrument measurements; δP<sub>s</sub> is the instrument error; δP<sub>t</sub> is the environment error.</p></sec><sec id="s4_2"><title>4.2. Uncertainty Evaluation</title><p>The experiment experience shows that the significant factors affecting the CDG accurate measurement such as measurement repeatability, apparatus, and temperature. Analysis of the uncertainty characteristics, the components (μ<sub>1</sub>) is type A evaluation of standard uncertainty and components (μ<sub>2</sub>, μ<sub>3</sub>) are type B.</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> The average residual error of CDG under different pressure</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >CDG</th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >0.08</td><td align="center" valign="middle" >0.18</td><td align="center" valign="middle" >0.14</td><td align="center" valign="middle" >0.11</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >0.18</td><td align="center" valign="middle" >0.16</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >0.12</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >−0.05</td><td align="center" valign="middle" >−0.06</td><td align="center" valign="middle" >−0.05</td><td align="center" valign="middle" >−0.03</td><td align="center" valign="middle" >−0.03</td><td align="center" valign="middle" >−0.08</td><td align="center" valign="middle" >−0.06</td><td align="center" valign="middle" >−0.02</td><td align="center" valign="middle" >−0.06</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >−0.03</td><td align="center" valign="middle" >−0.12</td><td align="center" valign="middle" >−0.09</td><td align="center" valign="middle" >−0.08</td><td align="center" valign="middle" >−0.03</td><td align="center" valign="middle" >−0.10</td><td align="center" valign="middle" >−0.10</td><td align="center" valign="middle" >−0.04</td><td align="center" valign="middle" >−0.06</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> The differential pressure of the static pressure</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >The differences of CDGs</th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >1 - 2</td><td align="center" valign="middle" >0.13</td><td align="center" valign="middle" >0.24</td><td align="center" valign="middle" >0.19</td><td align="center" valign="middle" >0.13</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >0.26</td><td align="center" valign="middle" >0.22</td><td align="center" valign="middle" >0.08</td><td align="center" valign="middle" >0.18</td></tr><tr><td align="center" valign="middle" >1 - 3</td><td align="center" valign="middle" >0.11</td><td align="center" valign="middle" >0.30</td><td align="center" valign="middle" >0.23</td><td align="center" valign="middle" >0.19</td><td align="center" valign="middle" >0.9</td><td align="center" valign="middle" >0.28</td><td align="center" valign="middle" >0.26</td><td align="center" valign="middle" >0.10</td><td align="center" valign="middle" >0.18</td></tr><tr><td align="center" valign="middle" >2 - 3</td><td align="center" valign="middle" >−0.02</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >0.00</td><td align="center" valign="middle" >0.02</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >0.02</td><td align="center" valign="middle" >0.00</td></tr></tbody></table></table-wrap><sec id="s4_2_1"><title>4.2.1. The Components (μ<sub>1</sub>) of the Uncertainty Caused by the Repeatability</title><p>Using a Bessel method to calculate a single measure standard deviation and the results are shown in <xref ref-type="table" rid="table3">Table 3</xref>.</p><p>The standard deviation of CDG2 is the smallest of the three at same pressure that explaining its stability is best. On the contrary, the stability of the CDG1 is the worst.</p><p>The average standard deviation<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/8-2310471x9.png" xlink:type="simple"/></inline-formula>, that is to say, The components of the uncertainty caused by the repeatability,<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/8-2310471x10.png" xlink:type="simple"/></inline-formula>. The results are as follows (<xref ref-type="table" rid="table4">Table 4</xref>).</p><p>The degrees of freedom υ<sub>1</sub> = n − 1 = 9</p></sec><sec id="s4_2_2"><title>4.2.2. The Components (μ<sub>2</sub>) of the Uncertainty Caused by the Apparatus</title><p>According to the instrument specifications, CDGs’ indication error (δ) is 0.2% readings. The indication error of setting pressure is shown in <xref ref-type="table" rid="table5">Table 5</xref>. According to uniformly distributed, the components of the uncertainty caused by the apparatus can be calculated as following.</p><p>Due to the stability of the instrument is reliable, the degrees of freedom υ<sub>2</sub> = ∞.</p></sec><sec id="s4_2_3"><title>4.2.3. The Components (μ<sub>3</sub>) of the Uncertainty Caused by the Temperature</title><p>According to the instrument specifications, CDGs’ error is 0.0050% F.S/˚C. Due to the indoor temperature at 20˚C &#177; 0.2˚C, the error δ = 0.0050% &#215; 1333 Pa/˚C &#215; 0.4˚C = 0.027 Pa. According to uniformly distributed, the components of the uncertainty caused by the temperature can be calculated from the simple relation.</p><disp-formula id="scirp.59236-formula1512"><graphic  xlink:href="http://html.scirp.org/file/8-2310471x11.png"  xlink:type="simple"/></disp-formula><p>Due to the stability of the instrument is reliable, Degrees of freedom υ<sub>2</sub> = ∞.</p></sec><sec id="s4_2_4"><title>4.2.4. Combined Uncertainty</title><p>The uncertainty components such as u<sub>1</sub>, u<sub>2</sub>, u<sub>3</sub> are independent of each other, that is to say, ρ<sub>ij</sub> = 0. The combined uncertainty<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/8-2310471x12.png" xlink:type="simple"/></inline-formula>, the results are as follows (<xref ref-type="table" rid="table6">Table 6</xref>).</p><p>The free degree of synthetic standard uncertainty was calculated from the following formula.</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Single measurement standard deviation</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >CDG</th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >0.016</td><td align="center" valign="middle" >0.014</td><td align="center" valign="middle" >0.029</td><td align="center" valign="middle" >0.012</td><td align="center" valign="middle" >0.016</td><td align="center" valign="middle" >0.010</td><td align="center" valign="middle" >0.011</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.011</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.013</td><td align="center" valign="middle" >0.013</td><td align="center" valign="middle" >0.011</td><td align="center" valign="middle" >0.016</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.007</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >0.017</td><td align="center" valign="middle" >0.010</td><td align="center" valign="middle" >0.018</td><td align="center" valign="middle" >0.010</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.013</td><td align="center" valign="middle" >0.010</td><td align="center" valign="middle" >0.013</td><td align="center" valign="middle" >0.012</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> The components (μ<sub>1</sub>) of the uncertainty caused by repeatability</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >CDG</th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >0.005</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.009</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.005</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.003</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.005</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.002</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >0.005</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.005</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.004</td><td align="center" valign="middle" >0.004</td></tr></tbody></table></table-wrap><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> The uncertainty caused by instrument error</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >δ</td><td align="center" valign="middle" >0.04</td><td align="center" valign="middle" >0.06</td><td align="center" valign="middle" >0.08</td><td align="center" valign="middle" >0.10</td><td align="center" valign="middle" >0.12</td><td align="center" valign="middle" >0.14</td><td align="center" valign="middle" >0.16</td><td align="center" valign="middle" >0.18</td><td align="center" valign="middle" >0.20</td></tr><tr><td align="center" valign="middle" >μ<sub>2</sub></td><td align="center" valign="middle" >0.023</td><td align="center" valign="middle" >0.035</td><td align="center" valign="middle" >0.046</td><td align="center" valign="middle" >0.056</td><td align="center" valign="middle" >0.069</td><td align="center" valign="middle" >0.081</td><td align="center" valign="middle" >0.093</td><td align="center" valign="middle" >0.104</td><td align="center" valign="middle" >0.116</td></tr></tbody></table></table-wrap><disp-formula id="scirp.59236-formula1513"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/8-2310471x13.png"  xlink:type="simple"/></disp-formula><p>The data in <xref ref-type="table" rid="table7">Table 7</xref> are large number can explain the evaluation of uncertainty is better.</p></sec><sec id="s4_2_5"><title>4.2.5. Expanded Uncertainty</title><p>Taking confidence probability P = 0.95, through the degrees of freedom in <xref ref-type="table" rid="table7">Table 7</xref> to check the t distribution table [<xref ref-type="bibr" rid="scirp.59236-ref6">6</xref>] , t<sub>0.95</sub>(υ) = 1.96, that is to say, coverage factor k = 1.96. The expanded uncertainty of pressure measurement is shown in <xref ref-type="table" rid="table8">Table 8</xref>.</p></sec><sec id="s4_2_6"><title>4.2.6. Discussion and Analysis</title><p>The results show the combined uncertainty and expanded uncertainty of CDGs are considered equal at same pressure. Relative to components μ<sub>2</sub> and μ<sub>3</sub>, components μ<sub>1</sub> is much smaller. That is to say, the experiment error caused by the repeatability is minimum. The CDG adopted in the experiment is the most accurate to measure vacuum pressure in the market. Lacking of a more precise instrument for reference, it is difficult to determine which regulate has the highest accuracy through experiment result but its stability can be judged by the standard deviation. Learn from the hydrostatic pressure difference of the CDG in this experiment, Follow-up experiments can accurately measure the pressure difference between two points of interior chamber.</p></sec></sec></sec><sec id="s5"><title>5. Conclusion</title><p>In a follow-up experiment, the measurement uncertainty was evaluated based on the results in Tables 6-8 when the CDG was used to measure the chamber pressure. The measurement results are corrected based on the hydrostatic pressure difference and measurement uncertainty when measuring pressure differences. The uncertainty evaluation process of measuring pressure can provide reference for vacuum measurement in the future and measurement pressure difference between two points of vacuum chamber can provide data support for designing process parameters.</p><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> The value of synthetic standard uncertainty</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >CDG</th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >0.028</td><td align="center" valign="middle" >0.038</td><td align="center" valign="middle" >0.050</td><td align="center" valign="middle" >0.060</td><td align="center" valign="middle" >0.071</td><td align="center" valign="middle" >0.082</td><td align="center" valign="middle" >0.094</td><td align="center" valign="middle" >0.105</td><td align="center" valign="middle" >0.117</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >0.028</td><td align="center" valign="middle" >0.038</td><td align="center" valign="middle" >0.049</td><td align="center" valign="middle" >0.060</td><td align="center" valign="middle" >0.071</td><td align="center" valign="middle" >0.082</td><td align="center" valign="middle" >0.094</td><td align="center" valign="middle" >0.105</td><td align="center" valign="middle" >0.117</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >0.028</td><td align="center" valign="middle" >0.038</td><td align="center" valign="middle" >0.049</td><td align="center" valign="middle" >0.060</td><td align="center" valign="middle" >0.071</td><td align="center" valign="middle" >0.082</td><td align="center" valign="middle" >0.094</td><td align="center" valign="middle" >0.105</td><td align="center" valign="middle" >0.117</td></tr></tbody></table></table-wrap><table-wrap id="table7" ><label><xref ref-type="table" rid="table7">Table 7</xref></label><caption><title> The free degree of synthetic standard uncertainty</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >CDG</th><th align="center" valign="middle" >20 Pa</th><th align="center" valign="middle" >30 Pa</th><th align="center" valign="middle" >40 Pa</th><th align="center" valign="middle" >50 Pa</th><th align="center" valign="middle" >60 Pa</th><th align="center" valign="middle" >70 Pa</th><th align="center" valign="middle" >80 Pa</th><th align="center" valign="middle" >90 Pa</th><th align="center" valign="middle" >100 Pa</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >9.2 &#215; 10<sup>3</sup></td><td align="center" valign="middle" >5.7 &#215; 10<sup>4</sup></td><td align="center" valign="middle" >7.6 &#215; 10<sup>3</sup></td><td align="center" valign="middle" >5.6 &#215; 10<sup>5</sup></td><td align="center" valign="middle" >3.2 &#215; 10<sup>5</sup></td><td align="center" valign="middle" >4.0 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >4.7 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >1.6 &#215; 10<sup>7</sup></td><td align="center" valign="middle" >1.4 &#215; 10<sup>7</sup></td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >9.0 &#215; 10<sup>4</sup></td><td align="center" valign="middle" >8.3 &#215; 10<sup>4</sup></td><td align="center" valign="middle" >1.7 &#215; 10<sup>5</sup></td><td align="center" valign="middle" >9.8 &#215; 10<sup>5</sup></td><td align="center" valign="middle" >3.7 &#215; 10<sup>5</sup></td><td align="center" valign="middle" >6.8 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >1.3 &#215; 10<sup>7</sup></td><td align="center" valign="middle" >2.1 &#215; 10<sup>7</sup></td><td align="center" valign="middle" >7.2 &#215; 10<sup>7</sup></td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >7.4 &#215; 10<sup>3</sup></td><td align="center" valign="middle" >1.6 &#215; 10<sup>5</sup></td><td align="center" valign="middle" >4.6 &#215; 10<sup>4</sup></td><td align="center" valign="middle" >1.1 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >3.3 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >1.5 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >8.6 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >3.5 &#215; 10<sup>6</sup></td><td align="center" valign="middle" >9.0 &#215; 10<sup>6</sup></td></tr></tbody></table></table-wrap><table-wrap id="table8" ><label><xref ref-type="table" rid="table8">Table 8</xref></label><caption><title> The value of expanded uncertainty</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >CDG</th><th align="center" valign="middle" >20/Pa</th><th align="center" valign="middle" >30/Pa</th><th align="center" valign="middle" >40/Pa</th><th align="center" valign="middle" >50/Pa</th><th align="center" valign="middle" >60/Pa</th><th align="center" valign="middle" >70/Pa</th><th align="center" valign="middle" >80/Pa</th><th align="center" valign="middle" >90/Pa</th><th align="center" valign="middle" >100/Pa</th></tr></thead><tr><td align="center" valign="middle" >1</td><td align="center" valign="middle" >0.056</td><td align="center" valign="middle" >0.075</td><td align="center" valign="middle" >0.097</td><td align="center" valign="middle" >0.117</td><td align="center" valign="middle" >0.140</td><td align="center" valign="middle" >0.162</td><td align="center" valign="middle" >0.184</td><td align="center" valign="middle" >0.206</td><td align="center" valign="middle" >0.230</td></tr><tr><td align="center" valign="middle" >2</td><td align="center" valign="middle" >0.055</td><td align="center" valign="middle" >0.075</td><td align="center" valign="middle" >0.096</td><td align="center" valign="middle" >0.117</td><td align="center" valign="middle" >0.140</td><td align="center" valign="middle" >0.162</td><td align="center" valign="middle" >0.184</td><td align="center" valign="middle" >0.206</td><td align="center" valign="middle" >0.230</td></tr><tr><td align="center" valign="middle" >3</td><td align="center" valign="middle" >0.056</td><td align="center" valign="middle" >0.075</td><td align="center" valign="middle" >0.096</td><td align="center" valign="middle" >0.117</td><td align="center" valign="middle" >0.140</td><td align="center" valign="middle" >0.162</td><td align="center" valign="middle" >0.184</td><td align="center" valign="middle" >0.206</td><td align="center" valign="middle" >0.230</td></tr></tbody></table></table-wrap></sec><sec id="s6"><title>Acknowledgements</title><p>The research work was supported by grant No.2011ZX02403-004 of the National Key Technology Research and Development Program of the Ministry of Science and Technology of China. A simulate system and experimental platform of IC Equipment including Process Chamber, supported by Multidisciplinary Collaborative Designing.</p></sec><sec id="s7"><title>Cite this paper</title><p>YulinZhou,XinQuan,TieniuYang, (2015) The Evaluation of Measurement Uncertainty and Its Application in the Vacuum Pressure Measurement. Open Journal of Applied Sciences,05,495-500. doi: 10.4236/ojapps.2015.58048</p></sec><sec id="s8"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.59236-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Wu, X.H., Wang, C.D. and Chen, F. (2015) Measurement Uncertainty Degree Analysis for the Actual Super Elevation of Calibrater for Track Inspection Instrument. Science Technology and Engineering, 15, 226-228, 238. (In Chinese)</mixed-citation></ref><ref id="scirp.59236-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Wang, Z.H.G., Ma, Y.T. and Lu, W. (2015) The Application of Uncertainty Analysis Theory in Thermal Efficiency Testing for Boiler. Proceedings of the CSEE, 25, 125-129. (In Chinese)</mixed-citation></ref><ref id="scirp.59236-ref3"><label>3</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Li</surname><given-names> Z.H. </given-names></name>,<etal>et al</etal>. (<year>1989</year>)<article-title>Several Questions Riveted Attention in the Application of Capacitance Diaphragm Gauge</article-title><source> Vacuum</source><volume> 3</volume>,<fpage> 51</fpage>-<lpage>53</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.59236-ref4"><label>4</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Li</surname><given-names> Z.H. </given-names></name>,<etal>et al</etal>. (<year>1998</year>)<article-title>Method for Evaluating the Uncertainty of Vacuum Measurement</article-title><source> Vacuum &amp; Cryogenics</source><volume> 4</volume>,<fpage> 181</fpage>-<lpage>183</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.59236-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Zhou, Y.L. and Yang, T.N. (2015) Air Tightness Testing and Analysis of Vacuum Chambers of IC Equipment. Journal of Wuyi University, 29, 59-63, 78. (In Chinese)</mixed-citation></ref><ref id="scirp.59236-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Fei, Y.T. (2005) The Error Theory and Data Processing. 4th Edition, China Machine Press, Beijing. (In Chinese)</mixed-citation></ref></ref-list></back></article>