<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">MSA</journal-id><journal-title-group><journal-title>Materials Sciences and Applications</journal-title></journal-title-group><issn pub-type="epub">2153-117X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/msa.2015.68078</article-id><article-id pub-id-type="publisher-id">MSA-59022</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Corrosion of Steel Pipelines Transporting Hydrocarbon Condensed Products, Obtained from a High Pressure Separator System: A Failure Analysis Study
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>erardo</surname><given-names>Zavala Olivares</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mónica</surname><given-names>Jazmín Hernández Gayosso</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Instituto Mexicano Del Petróleo. Eje Central Lázaro Cárdenas Norte,Col. San Bartolo Atepehuacan, C.P., México
D.F., México</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>gzavala@imp.mx(EZO)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>04</day><month>08</month><year>2015</year></pub-date><volume>06</volume><issue>08</issue><fpage>760</fpage><lpage>772</lpage><history><date date-type="received"><day>11</day>	<month>July</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>20</month>	<year>August</year>	</date><date date-type="accepted"><day>24</day>	<month>August</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this paper, the corrosion of steel pipelines transporting hydrocarbon condensed products was studied. Different activities of sampling and analysis were carried out to diagnose the failure causes and to establish a control system for the corrosion problem. The combination of three types of corrosion, including erosion corrosion, galvanic corrosion and microbiologically induced corrosion, was synthetically considered. A serial of experiments were designed to research those types of corrosion. This type of failure was observed in characteristics sites of the pipeline, mainly in direction changes and welding joints. Additionally, localized corrosion was observed in the inner steel wall and distributed along the pipeline, although a tendency was not detected.
 
</p></abstract><kwd-group><kwd>Erosion Corrosion</kwd><kwd> Galvanic Corrosion</kwd><kwd> Microbiologically Induced Corrosion</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Nowadays, hydrocarbon transportation in the oil industry is accomplished through pipelines. Huge volume of gas and liquid can be transported in an efficient and safe way. During the gas-oil separation processes, the operational parameters may come out of control and some operational problems may occur, including corrosion failures.</p><p>A corrosion problem was observed in a 2 inches diameter steel pipeline, transporting hydrocarbon condensed products obtained from a high pressure separator system located in an offshore platform in the Gulf of Mexico. This situation generated critical conditions that favored the pipeline corrosion development and resulted in some leaks. Initially, it was presumed that the failure could be caused by effect of microbiologically induced corrosion. However, as the failures did not exhibit a regular pattern, it was considered that others types of corrosion were involved in the problematic. According to this, several activities, mainly directed to diagnose the failure conditions, were carried out [<xref ref-type="bibr" rid="scirp.59022-ref1">1</xref>] - [<xref ref-type="bibr" rid="scirp.59022-ref3">3</xref>] .</p><p>Therefore, it was intended to diagnose the causes for the corrosion failures in the pipeline at the output of the high pressure separator system. With this, recommendations for corrosion control can be made.</p></sec><sec id="s2"><title>2. Activities</title><p>The activities carried out were divided in two stages: Stage 1 focused on the characterization of the hydrocarbon streams, at the sites where the leaks occurred. This was in order to determine the main corrosive agents in the system. Stage 2 directed to analyze the corrosion products at the metal surface, as well as the type and morphology of the corrosion process. With these activities, the causes for the corrosion failures could be established.</p><sec id="s2_1"><title>2.1. Stage 1</title><p>Two monitoring points were selected, considering streams that were incorporated to the system that exhibited the leak. These points were named P-I and P-II.</p><p>Field activities: Initially, an inspection of the system was carried out, to identify the monitoring points and to collect both, water and condensed products. Four samples were taken from the monitoring points, leaving a gap of 24 hours between each sampling [<xref ref-type="bibr" rid="scirp.59022-ref4">4</xref>] .</p><p>For water samples, different parameters were measured in situ: Temperature, Pressure, pH, O<sub>2</sub> content, CO<sub>2</sub> content, H<sub>2</sub>S content, conductivity and presence of sulfate reducing bacteria (SRB) [<xref ref-type="bibr" rid="scirp.59022-ref5">5</xref>] .</p><p>Laboratory activities: Physical and chemical analysis were carried out to water samples. The analysis for the condensed products samples were: hydrocarbon characterization, O<sub>2</sub> content, CO<sub>2</sub> content, H<sub>2</sub>S content, humidity, Sulfur compounds [<xref ref-type="bibr" rid="scirp.59022-ref6">6</xref>] .</p></sec><sec id="s2_2"><title>2.2. Stage 2</title><p>A leak occurred in a 2 inches steel pipeline transporting hydrocarbon condensed products. A section of the pipeline, where the failure occurred, was cut and replaced. The sample was prepared and sent to the laboratory, for its respective analysis. Once the sample was at the laboratory, the failure was located and corrosion products were obtained from the adjacent area. Different analysis were carried out, including X-ray diffraction and fluorescence, M&#246;ssbauer spectroscopy, surface analysis, hardness, chemical analysis and identification of sulfate reducing bacteria, among others.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Stage 1</title><sec id="s3_1_1"><title>3.1.1. Water Analysis</title><p>During the sampling procedure, it was observed that the hydrocarbon obtained exhibited high water content. Water is necessary when a corrosion process is taking place and the extent of the damage depends on its corrosive characteristics.</p><p>In all cases, the samples were identified as condensation water, with low conductivity. However, the Langelier index indicated a corrosive tendency for all samples [<xref ref-type="bibr" rid="scirp.59022-ref7">7</xref>] . Values between −3 and −5 were observed, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. This situation implies that water may become very aggressive to the metallic structures.</p><p>Additionally, it must be indicated that the water corrosiveness for these systems was also related to the content of dissolved gases, including H<sub>2</sub>S, CO<sub>2</sub> and O<sub>2</sub>. For this case, the H<sub>2</sub>S concentration was between 5 and 45 ppm, O<sub>2</sub> between 0 and 2.6 ppm and CO<sub>2</sub> between 28 and 75 ppm (Figures 2-4). The presence of these gases in water and hydrocarbon represents a corrosion risk for the metallic structures, and a prevention system must be considered [<xref ref-type="bibr" rid="scirp.59022-ref8">8</xref>] - [<xref ref-type="bibr" rid="scirp.59022-ref10">10</xref>] .</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Langelier Index Stability (LIS) for water samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x6.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> H<sub>2</sub>S concentration in water samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x7.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> O<sub>2</sub> concentration in water samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x8.png"/></fig><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> CO<sub>2</sub> concentration in water samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x9.png"/></fig><p>It is important to point out that the variations observed between the analyzed samples for P-I and P-II are slight; therefore, their corrosive tendency is similar. At the same time, the O<sub>2</sub> and CO<sub>2</sub> contents exhibit some differences that are considered as normal, due to the fluid characteristic variations.</p><p>One of the parameters that present bigger differences is the H<sub>2</sub>S content. Here, an increase with time for samples taken from P-I was observed, reporting values between 20 and 40 mg/l. For samples taken from P-II, lower values were reported, in the range of 5 and 30 mg/l. It must be noted that the concentration of corrosive gases in water depends upon the general characteristics of the hydrocarbon, specially pressure and temperature. Therefore, the results allow establishing the presence of corrosive gases in the analyzed water samples.</p><p>In the same way, it may be indicated that iron content in the water samples is a reference to establish whether the corrosion process is taking place or not, and to determine the necessity of a control system [<xref ref-type="bibr" rid="scirp.59022-ref11">11</xref>] . For this case, both fluids P-I and P-II exhibited corrosive characteristics, although a difference in the iron content could be observed (<xref ref-type="fig" rid="fig5">Figure 5</xref>).</p><p>The samples taken in P-I had values around 0.5 ppm, while the samples from P-II reported values between 3.3 and 4.2 ppm.</p><p>These differences can be related to some specific system conditions and parameters:</p><p>• Chemical composition and/or material resistance;</p><p>• Temperature;</p><p>• Flow;</p><p>• System life time;</p><p>• Addition of chemicals, such as corrosion inhibitors, scale inhibitors, among others;</p><p>• Process efficiency.</p><p>On the other hand, the presence of microorganisms was determined in all water samples. Sulfate reducing bacteria populations around 100 bacteria/cm<sup>3</sup> were observed. This situation is considered as a potential problem of localized corrosion.</p></sec><sec id="s3_1_2"><title>3.1.2. Hydrocarbon Analysis</title><p>The fluid is mainly composed of light hydrocarbons, such as methane, ethane and propane. This is considered as a normal situation. However, there were some corrosive gases in the hydrocarbon composition. Contents of H<sub>2</sub>S, CO<sub>2</sub> and O<sub>2</sub> were determined, as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref> and <xref ref-type="fig" rid="fig7">Figure 7</xref>. Here, both points P-I and P-II, show similar gases proportion.</p><p>Considering their effect on the corrosion processes, these gases represent a continuous source of corrosive compounds for the aqueous phase. Once the products are consumed in the reaction, the gases dissolve in water to keep the corrosion process going on.</p><p>According to the fluid characteristics, the parameters identified as the responsible for the corrosion process in the systems are:</p><p>1) Water content;</p><p>2) Presence of dissolved corrosive gases;</p><p>3) Presence of microorganisms, mainly Sulfate reducing bacteria (SRB);</p></sec></sec><sec id="s3_2"><title>3.2. Stage 2</title><p>The analyzed sample was taken at the exit of a high pressure separator, as shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>. The pipeline had</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Fe<sup>2+</sup> Concentration in water samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x10.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Concentration of corrosive gases in hydrocarbon composition (P-I)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x11.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Concentration of corrosive gases in hydrocarbon composition (P-II)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x12.png"/></fig><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> Diagram of the high pressure separator system</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x13.png"/></fig><p>closed valves at the ends and nitrogen gas was bubbled inside, to assure anoxic conditions.</p><p>The failure was located at the welding joint with the first elbow, according to the fluid flow and at the 6 tech- nical hours position, as shown in <xref ref-type="fig" rid="fig9">Figure 9</xref>.</p><p>The sample analyses were carried out as follows.</p><sec id="s3_2_1"><title>3.2.1. Microbiological Analysis</title><p>The presence of sulfate reducing bacteria (SRB) was identified inside the pipeline, next to the failure and in dif-</p><fig-group id="fig9"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Location of the site where failure occurs.</title></caption><fig id ="fig9_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x14.png"/></fig><fig id ="fig9_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x15.png"/></fig></fig-group><p>ferent areas along the inner wall. SRB have been considered as the main agent for the microbiological induced corrosion occurring in hydrocarbon transport and distribution systems [<xref ref-type="bibr" rid="scirp.59022-ref12">12</xref>] - [<xref ref-type="bibr" rid="scirp.59022-ref14">14</xref>] .</p><p>SRB presence was determined using culture media, according to API Recommended Practice No. 38 [<xref ref-type="bibr" rid="scirp.59022-ref15">15</xref>] . This is a specific culture for this kind of microorganisms.</p><p>When SRB are present in the samples, they reduce the sulfate of the media to sulfide, which reacts with iron to produce a black precipitate of iron sulfide. This is an indicative of SRB presence. When there is no presence of SRB, the culture media remains transparent with no change (<xref ref-type="fig" rid="fig1">Figure 1</xref>0).</p><p>The formation of FeS deposits at the metal surface is one of the main characteristics of this type of corrosion. These results are in good agreement with those obtained in Stage 1, where the presence of SRB in water was indicated.</p><p>It is important to point out that the presence of SRB constitutes a risk for the integrity of metallic structures, as these microorganisms induce localized corrosion. Therefore, its identification and control becomes necessary.</p></sec><sec id="s3_2_2"><title>3.2.2. X-Ray Diffraction, X-Ray Fluorescence and M&#246;ssbauer Spectroscopy Analyses</title><p>The corrosion products obtained from the metal surface were analyzed by different techniques: X-ray diffraction, X-ray fluorescence, and M&#246;ssbauer spectroscopy. The following was observed:</p><p>M&#246;ssbauer Spectroscopy: This analysis is specific to determine iron compounds. The spectrum obtained is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>1. The compounds found mainly correspond to iron sulfides: Troilite (FeS), Mackinawite (FeS<sub>0.9</sub>) and FeS<sub>2</sub>.</p><p>X-Ray Fluorescence: This technique is directed to establish the presence of chemical elements in the sample. The results indicate different elements, mainly S, Fe and O.</p><p>X-Ray Diffraction: Using this technique, the presence of diverse compounds with crystalline structure can be identified. The obtained diagram exhibited the following compounds: Mackinawite (FeS<sub>0.9</sub>), Marcasite (FeS<sub>2</sub>), Pyrite (FeS<sub>2</sub>), Troilite (FeS) and Pyrrhotite (FeS).</p><p>According to theses analyses, it may be possible to establish that the main corrosion products formed at the inner metal surface are iron sulfides, which may result from:</p><p>• The presence of H<sub>2</sub>S in the hydrocarbon and the associated water;</p><p>• The activity of SRB, which was identified in the system. Iron sulfide is a sub-product of the microorganism metabolism.</p><p>It is important to mention that although the X-ray fluorescence analysis indicated oxygen content, no oxides were identified by X-ray diffraction nor M&#246;sbauer spectroscopy. In this way, it must be said that during the first inspection of the corrosion products at the metal surface, some “reddish” products characteristics for oxide compounds were observed. These red products were entrusted in the interstices of the inner metal wall, underneath the metal-corrosion products interface. For this reason, the oxides were not detected, even though its presence was visually corroborated.</p></sec><sec id="s3_2_3"><title>3.2.3. Surface Analysis</title><p>Several surface analyses, using the Scanning Electron Microscope, were carried out at the site where the failure</p><fig-group id="fig10"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>0</label><caption><title> Presence of sulfate reducing bacteria, indicated by the formation of FeS deposits. a) Presence of SRB; b) Presence of SRB; c) Absence of SRB (Blank).</title></caption><fig id ="fig10_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x16.png"/></fig><fig id ="fig10_2"><label> (c)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x17.png"/></fig><fig id ="fig10_3"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x18.png"/></fig></fig-group><fig id="fig11"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>1</label><caption><title> Spectrum obtained from M&#246;ssbauer spectroscopy</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x19.png"/></fig><p>occurred, before and after the corrosion products were removed from the metal surface [<xref ref-type="bibr" rid="scirp.59022-ref16">16</xref>] . The results corresponding to the analysis with corrosion products at the surface, exhibited a rectangular failure, with side dimensions of 253 μm and 629 μm, located at the welding joint (<xref ref-type="fig" rid="fig1">Figure 1</xref>2). An elemental analysis indicated a typical mild steel composition, including Fe, C, Ni, Cr, Si, and Mn.</p><p>Moreover, S and O were observed. These elements are associated to the steel composition, but also could be related to the corrosion products formed at the metal surface. Once the corrosion products were removed, a surface analysis was carried out. A uniform corrosion process was observed in the entire metal surface, with a type of localized corrosion in specific sites (<xref ref-type="fig" rid="fig1">Figure 1</xref>3).</p><p>In this case, the characteristics elements for carbon steel are still observed. However, there is lower oxygen content and the presence of sulfur was detected. These results corroborate the fact that the corrosion products are mainly formed by sulfides and oxides. Additionally, as the failure occurred in a welding joint, a galvanic corrosion effect was considered and a metallographic analysis was suggested.</p><fig id="fig12"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>2</label><caption><title> Micrograph of failure. Corrosion products at the metal surface</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x20.png"/></fig><fig id="fig13"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>3</label><caption><title> Micrograph of failure. Metal surface free of corrosion products</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x21.png"/></fig></sec><sec id="s3_2_4"><title>3.2.4. Metallographic Analysis</title><p>A metallographic analysis and a hardness profile were carried out at the site where the failure occurred, considering the tube, the welding joint and the elbow. During the sample preparation, inclusions at the metal surface were evaluated. Sulfides and oxides were observed in the tube and oxides were noticed at the elbow surface. These results corroborate previous analysis, where the presence of these two compounds was reported. Regarding the hardness profile, the results indicate similar behavior for the three regions analyzed: tube, welding joint and elbow. Values around 74 Rockwell units (HRBW) were measured. However, the heat affected regions (HAR) exhibited higher hardness values, around 86 HRB, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>4.</p><p>On the other hand, according to the metallographic analysis, the tube―elbow microstructure arrangement indicated the presence of Pearlite and Ferrite, as shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><p>It is important to point out that the steel physical properties and its behavior depend mainly upon the carbon content and its distribution into the iron matrix. Most of the steels are a combination of three phases: pearlite,</p><fig id="fig14"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>4</label><caption><title> Hardness profile for the metal sample</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x22.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Microstructures present in the materials</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Analysis Region</th><th align="center" valign="middle" >Microstructure</th></tr></thead><tr><td align="center" valign="middle" >Elbow</td><td align="center" valign="middle" >Pearlite + Ferrite<sup>(a)</sup></td></tr><tr><td align="center" valign="middle" >HAR</td><td align="center" valign="middle" >Proeutectoid pearlite + fine pearlite</td></tr><tr><td align="center" valign="middle" >Welding joint</td><td align="center" valign="middle" >Proeutectoid pearlite + dendrites</td></tr><tr><td align="center" valign="middle" >HAR</td><td align="center" valign="middle" >Proeutectoid pearlite + fine pearlite</td></tr><tr><td align="center" valign="middle" >Tube</td><td align="center" valign="middle" >Pearlite + Ferrite<sup>(b)</sup></td></tr><tr><td align="center" valign="middle" >Tube in corroded region</td><td align="center" valign="middle" >Pearlite + Ferrite</td></tr><tr><td align="center" valign="middle" >Elbow in corroded region</td><td align="center" valign="middle" >Pearlite + Ferrite</td></tr></tbody></table></table-wrap><p>(a) Grain size 9; (b) Grain size 7 - 8</p><p>cementite and ferrite. The strength and hardness of steel with no heat treatment depend on the proportion of these three phases.</p><p>For this specific case, a typical carbon steel microstructure formed by ferrite and pearlite was observed for the tube and elbow. The welding joint material had a microstructure formed mainly by proeutectoid pearlite that can be considered as typical for low carbon steel. The presence of dendrites in the welding joint may be related to a material heat effect. The regions identified as HAR presented microstructures constituted mainly by proeutectoid pearlite and fine pearlite. The different microstructures shown by each region could indicate a galvanic effect that contributes to the corrosion process at the failure site, which also corresponds to the welding joint region.</p></sec><sec id="s3_2_5"><title>3.2.5. Chemical Analysis</title><p>To complete the metallographic analysis and to identify any difference between the chemical composition of the tube, elbow and welding joint, a chemical analysis was carried out, using the Atomic Absorption Technique. This was done to determine the elements present in the metals and the results are summarized in <xref ref-type="table" rid="table2">Table 2</xref>. According to this table, the tube and elbow had similar chemical composition, indicating the same type of steel. However, the welding joint material presented some significant differences, mainly related to the content of Fe, C, Mn, Si and S.</p><p>A galvanic effect could be explained by these differences and the different microstructures observed in the metals. It seems that the welding joint material acts as an anode and the adjacent regions as a cathode.</p></sec><sec id="s3_2_6"><title>3.2.6. Corrosion Process Morphology</title><p>The results obtained at this moment indicate that there are right conditions in the system for the development of a corrosion process in the inner wall of the pipeline. There is high water content, in addition to the presence of corrosive agents and appropriate material conditions. For the failure considered in this work, different corrosion processes were observed:</p><p>1) The first visual inspection of the pipeline inner wall, after the first metal cut and before any metal cleaning, indicated a severe uniform corrosion, identified by a reduction of the pipeline thickness in specific sites, mainly located at the 6 hours position (<xref ref-type="fig" rid="fig1">Figure 1</xref>5).</p><p>This type of corrosion was generally observed at the elbows and “T” joints, where the fluid changes its flow direction. It is expected that during the hydrocarbon transport, heavier fluids are located at the bottom of the pipeline. For this specific case, water phase is in this position, generating aggressive conditions for the metal.</p><p>Due to the morphology, location and distribution of this type of uniform corrosion, an erosion corrosion effect is considered. In this type of corrosion, the hydrocarbon flow is enough to remove corrosion products from the metal surface, decreasing their protective effect and increasing the corrosion rate. Corrosion processes due to fluids flow usually induced a localized impact pattern. The failure was located at the welding joint, in a site where an erosion corrosion effect was also observed, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>6.</p><p>In this way, it is very important to verify the fluid velocity, as it should not exceed the recommended material limits. From a corrosion point of view, a smooth flow is always preferable to a turbulent flow. At the same time, gases and solid particles must be eliminated from the fluid as possible.</p><fig id="fig15"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>5</label><caption><title> Pipeline transverse cutting. First elbow after the high pressure separator</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x23.png"/></fig><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Chemical composition of metal samples</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Metal</th><th align="center" valign="middle"  colspan="3"  >Chemical Composition</th></tr></thead><tr><td align="center" valign="middle" >Elbow (%)</td><td align="center" valign="middle" >Welding joint (%)</td><td align="center" valign="middle" >Tube (%)</td></tr><tr><td align="center" valign="middle" >Cr</td><td align="center" valign="middle" >0.03</td><td align="center" valign="middle" >0.05</td><td align="center" valign="middle" >0.03</td></tr><tr><td align="center" valign="middle" >Mn</td><td align="center" valign="middle" >0.79</td><td align="center" valign="middle" >1.19</td><td align="center" valign="middle" >0.92</td></tr><tr><td align="center" valign="middle" >Mo</td><td align="center" valign="middle" >0.02</td><td align="center" valign="middle" >&lt;0.01</td><td align="center" valign="middle" >&lt;0.01</td></tr><tr><td align="center" valign="middle" >Ni</td><td align="center" valign="middle" >0.08</td><td align="center" valign="middle" >0.02</td><td align="center" valign="middle" >0.03</td></tr><tr><td align="center" valign="middle" >Si</td><td align="center" valign="middle" >0.31</td><td align="center" valign="middle" >0.62</td><td align="center" valign="middle" >0.19</td></tr><tr><td align="center" valign="middle" >C</td><td align="center" valign="middle" >0.195</td><td align="center" valign="middle" >0.043</td><td align="center" valign="middle" >0.163</td></tr><tr><td align="center" valign="middle" >S</td><td align="center" valign="middle" >0.003</td><td align="center" valign="middle" >0.024</td><td align="center" valign="middle" >0.002</td></tr><tr><td align="center" valign="middle" >P</td><td align="center" valign="middle" >0.018</td><td align="center" valign="middle" >0.023</td><td align="center" valign="middle" >0.022</td></tr><tr><td align="center" valign="middle" >Fe</td><td align="center" valign="middle" >98.60</td><td align="center" valign="middle" >97.96</td><td align="center" valign="middle" >98.66</td></tr></tbody></table></table-wrap><fig id="fig16"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>6</label><caption><title> Site where failure occurs. Erosion corrosion goes in flow direction</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x24.png"/></fig><p>2) A galvanic corrosion process may be considered at the welding joints regions. This type of corrosion occurs because of potential differences between metallic materials, when in contact and in presence of an electrolyte. The material with more negative potential acts as an anode and exhibited a corrosion process. For this specific case, apparently the welding joint acted as anode in the corrosion reaction. However, the galvanic corrosion was less evident in the site where the failure occurred, because of the effect of the erosion corrosion. At the 12 technical hours position, the erosion corrosion effect is less evident and the galvanic corrosion is clearly observed (<xref ref-type="fig" rid="fig1">Figure 1</xref>7).</p><p>3) Microbiological induced corrosion, which can be associated to localized corrosion processes, was observed along the metal sample. It was more evident at longitudinal regions, between 5 and 7 technical hours positions, although this type of corrosion was also detected in most of the pipeline inner metal surface, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>8. Corrosion products were removed from some pits and SRB populations were detected inside the cavities.</p><p>Additionally, microorganisms were also detected at the region where the failure occurred. This situation indicated that microbiological induced corrosion had also an effect on the metal failure, although the evidences were not clear, because of the presence of the other types of corrosion.</p></sec></sec></sec><sec id="s4"><title>4. Conclusions</title><p>• The hydrocarbon condensed products transported by the 2 inches diameter steel pipeline, at the exit of the high pressure separator system, exhibited aggressive conditions for the inner metal wall. The main corrosive agents identified in the fluid are:</p><p>1) Water content;</p><p>2) The presence of dissolved gases (H<sub>2</sub>S, CO<sub>2</sub> and O<sub>2</sub>);</p><p>3) Microorganisms population, mainly sulfate reducing bacteria.</p><p>• The problem was considered as a combined effect of three types of corrosion:</p><p>1) Erosion corrosion, caused by the fluid flow and changes in the fluid direction;</p><p>2) Galvanic corrosion, mainly caused by differences in the chemical composition and microstructures of the metallic materials;</p><p>3) Microbiologically induced corrosion, caused by the presence of sulfate reducing bacteria.</p><p>• The corrosive agents in the system, such as CO<sub>2</sub>, H<sub>2</sub>S and O<sub>2</sub>, participate in the cathodic reaction during the corrosion process.</p><p>• This type of failure occurs in characteristic sites of the pipelines path, mainly in direction changes and in welding joints.</p><p>• However, localized corrosion processes must also be considered. This type of corrosion does not follow a specific pattern, and becomes more important in sites where flow does not have influence.</p><fig id="fig17"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>7</label><caption><title> Corrosion process at the interface tube-elbow</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x25.png"/></fig><fig-group id="fig18"><label><xref ref-type="fig" rid="fig1">Figure 1</xref>8</label><caption><title> Localized corrosion at the elbow inner wall.</title></caption><fig id ="fig18_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x26.png"/></fig><fig id ="fig18_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7701652x27.png"/></fig></fig-group></sec><sec id="s5"><title>5. Recommendations</title><p>The cause for the failure observed in the system is a combined effect of different corrosion types and therefore several actions must be considered:</p><p>1) To install an inhibitor injection system. The inhibitor considered must remove the oxygen in the system and form a film in the metal surface;</p><p>2) To consider a biocide injection program;</p><p>3) To verify the specifications of the system, relating to the hydrocarbon transport, in order to control the fluid flow, according to the separator system design;</p><p>4) To eliminate the water content, as it represents one of the main corrosive agents. A modification on the separation equipment should be considered;</p><p>5) To carry out a fluid quality control program;</p><p>6) To review the welding procedures, in order to eliminate any discontinuity in the inner pipeline wall;</p><p>7) To consider a heat treatment for stress relieve, after heat treatment;</p><p>8) To maintain a constant flow in the pipelines.</p></sec><sec id="s6"><title>Cite this paper</title><p>Gerardo ZavalaOlivares,M&#243;nica Jazm&#237;n Hern&#225;ndezGayosso, (2015) Corrosion of Steel Pipelines Transporting Hydrocarbon Condensed Products, Obtained from a High Pressure Separator System: A Failure Analysis Study. Materials Sciences and Applications,06,760-772. doi: 10.4236/msa.2015.68078</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.59022-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">(2006) NACE Standard SP0106-2006: Control of Internal Corrosion in Steel Pipelines and Piping Systems. NACE International, Houston.</mixed-citation></ref><ref id="scirp.59022-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">(1991) API RP 14E: Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems. API, Washington DC.</mixed-citation></ref><ref id="scirp.59022-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">(2002) NACE Standard RP0102: In Line Inspection of Pipelines. NACE International, Houston.</mixed-citation></ref><ref id="scirp.59022-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">(2010) ASTM D 3370. Sampling Water from Closed Conduits.</mixed-citation></ref><ref id="scirp.59022-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">(2014) NACE Standard TM0194-2014: Field Monitoring of Bacterial Growth in Oil and Gas Systems. NACE International, Houston.</mixed-citation></ref><ref id="scirp.59022-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">(2012) ASTM D5504-12: Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence.</mixed-citation></ref><ref id="scirp.59022-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Pisigan Jr., R.A. and Singley, J.E. (1985) Evaluation of Water Corrosivity Using the Langelier Index and Relative Corrosion Rate Models. Materials Performance, 24, 26-36.</mixed-citation></ref><ref id="scirp.59022-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Sastri, V.S. (1998) Corrosion Inhibitors, Principles and Applications. John Wiley and Sons, New York.</mixed-citation></ref><ref id="scirp.59022-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Callister, W.D. (2000) Materials Science and Engineering: An Introduction. John Wiley and Sons, New York.</mixed-citation></ref><ref id="scirp.59022-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Byars, H. (1999) Corrosion Control in Petroleum Production. 2nd Edition, NACE International, Houston.</mixed-citation></ref><ref id="scirp.59022-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Atkinson, J.T.N. (1985) Corrosion and Its Control: An Introduction to the Subject. NACE International, Houston.</mixed-citation></ref><ref id="scirp.59022-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">(2002) ASTM D 4412-84: Standard Test Method for Sulfate Reducing Bacteria in Water Formed Deposits.</mixed-citation></ref><ref id="scirp.59022-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Ghazy, E.A., Mahmoud, M.G., Asker, M.S., Mahmoud, M.N., Abo Elsoud, M.M. and Abdel Sami, M.E. (2011) Cultivation and Detection of Sulfate Reducing Bacteria (SRB) in Sea Water. Journal of American Science, 7, 604-608.</mixed-citation></ref><ref id="scirp.59022-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">(1995) ASTM F488-95: Standard Test Method for On-Site Screening of Heterotrophic Bacteria in Water.</mixed-citation></ref><ref id="scirp.59022-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">(1982) API Recommended Practice No. 38: Biological Analysis for Subsurface Injection Waters. API, Philadelphia.</mixed-citation></ref><ref id="scirp.59022-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">(2011) ASTM G1-03: Standard Practice for Preparing, Cleaning, and Evaluating Corrosion Test Specimens.</mixed-citation></ref></ref-list></back></article>