<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">MSA</journal-id><journal-title-group><journal-title>Materials Sciences and Applications</journal-title></journal-title-group><issn pub-type="epub">2153-117X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/msa.2015.68075</article-id><article-id pub-id-type="publisher-id">MSA-58598</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Biomechanical Analysis of Implant Assisted-Overdentures with Variations in the Attachments Systems
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>duardo</surname><given-names>Vedovatto</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jose</surname><given-names>Vitor Quinelli Mazaro</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Humberto</surname><given-names>Gennari Filho</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Paulo</surname><given-names>Sérgio Perri de Carvalho</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Caroline</surname><given-names>Cantieri de Mello</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Cleidiel</surname><given-names>Aparecido Araujo Lemos</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>S&amp;amp;atilde;o Leopoldo MandicInstituteandResearch Center, Campinas, Brazil</addr-line></aff><aff id="aff3"><addr-line>Department of Surgery an Integrated Clinic, Ara&amp;amp;ccedil;atuba School of Dentistry, S&amp;amp;atilde;o Paulo State
University (UNESP), Ara&amp;amp;ccedil;atuba, Brazil</addr-line></aff><aff id="aff2"><addr-line>Department of Prosthodontic and Dental Materials, Ara&amp;amp;ccedil;atuba School of Dentistry, S&amp;amp;atilde;o Paulo State University
(UNESP), Ara&amp;amp;ccedil;atuba, Brazil</addr-line></aff><aff id="aff4"><addr-line>Departmentof Dental Materials and Prosthodontics, Ara&amp;amp;ccedil;atuba SchoolofDentistry, S&amp;amp;atilde;o Paulo StateUniversity
(UNESP), Ara&amp;amp;ccedil;atuba, Brazil.</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>zevitormazaro@foa.unesp.br, zevitormazaro@gmail.com(JVQM)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>04</day><month>08</month><year>2015</year></pub-date><volume>06</volume><issue>08</issue><fpage>734</fpage><lpage>742</lpage><history><date date-type="received"><day>28</day>	<month>May</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>31</month>	<year>July</year>	</date><date date-type="accepted"><day>5</day>	<month>August</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The aim of this study was to assess the stress patterns on the peri-implant zone and residual alveolar ridge in different overdenture attachment system designs by the photoelasticity method. Four attachments systems were tested: O-ring, ERA, Bar-clip, and Bar-clip/O-ring association. The prostheses were loaded with 100 N in five pre-determined points and the photoelastic model was evaluated by a circular polariscope. The anterior load, O-ring, and ERA showed better stress distribution in relation to the bars systems, which presented stress levels surrounding implants. The molar load, Bar-clip/O-ring association, presented the biggest stress concentration on the peri-implant region in relation to the others. When the second molar was loaded, there was a concentration of stress in the alveolar ridge in all situations analyzed. Within the limitation of this “
  <em>in vitro</em>” study, it could be concluded that there were biomechanical differences among the attachments systems analyzed, principally between isolated and the bars systems. The O-ring showed better stress distribution and the Bar-clip/O-ring showed higher stress concentration.
 
</p></abstract><kwd-group><kwd>Dental Implants</kwd><kwd> Complete Denture</kwd><kwd> Overdentures</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Edentulism is considered as a public health problem that affects most of the population [<xref ref-type="bibr" rid="scirp.58598-ref1">1</xref>] and interferes in the quality of life of patients, both physically and psychologically [<xref ref-type="bibr" rid="scirp.58598-ref2">2</xref>] . Furthermore, recent studies suggest that tooth loss affects the intake of nutrients, due to a significant reduction of masticatory efficiency, [<xref ref-type="bibr" rid="scirp.58598-ref3">3</xref>] and could increase the risk for several diseases [<xref ref-type="bibr" rid="scirp.58598-ref4">4</xref>] - [<xref ref-type="bibr" rid="scirp.58598-ref6">6</xref>] .</p><p>In this sense, dental implants have been used for improving the masticatory capacity in fully edentulous patients, favoring an increase in the quality of life of these patients [<xref ref-type="bibr" rid="scirp.58598-ref7">7</xref>] . Two treatment modalities are widely used for the rehabilitation of fully edentulous patients: overdentures and fixed full-arch prosthesis [<xref ref-type="bibr" rid="scirp.58598-ref8">8</xref>] , the indication depends on the individualities of each patient to be rehabilitated [<xref ref-type="bibr" rid="scirp.58598-ref9">9</xref>] .</p><p>Sometimes, a greater number of implants cannot be installed, thereby limiting the installation of fixed full- arch prosthesis [<xref ref-type="bibr" rid="scirp.58598-ref10">10</xref>] . In these cases, overdentures are indicated due to higher stability and retention than conventional dentures [<xref ref-type="bibr" rid="scirp.58598-ref11">11</xref>] . For this type of rehabilitation treatment, different attachment systems are available: O-ring, ERA, Bar-clip, or associations among the systems [<xref ref-type="bibr" rid="scirp.58598-ref12">12</xref>] .</p><p>The clinical success and longevity of dental implants are influenced by the stress distribution transferred to implant and surrounding bone [<xref ref-type="bibr" rid="scirp.58598-ref13">13</xref>] . The different attachment systems used in overdentures present different biomechanical characteristics, and can offer risk to osseointegrated implants [<xref ref-type="bibr" rid="scirp.58598-ref14">14</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref15">15</xref>] . In vitro studies have analyzed stress distribution in peri-implant bone, avoiding unnecessary risks. However, there is no consensus in the literature about the biomechanical effect of attachment systems that are different for overdentures prosthesis. Thus, the aim of this in vitro study is to analyze by the photoelasticity method the stress distribution in peri-im- plant bone and the alveolar ridge when using different attachment systems for the overdentures. The research hypothesis is that there is no difference in stress distribution among the attachment systems evaluated.</p></sec><sec id="s2"><title>2. Materials and Methods</title><p>The model representing an edentulous mandible was duplicated with laboratory silicon (Silibor, ArtigosOdontol&#243;gicos Cl&#225;ssico Ltda., S&#227;o Bernardo do Campo, SP, Brazil) to obtain a study model. The model was drilled on the regions of inferior canines and was performed dental implants placement coupled to a parallelometer and fixed with acrylic resin (Duralay, Reliance Denture MgfInc Co., Alsip, IL, USA). Square copings were screwed in the implants and the model was duplicated with silicon impression material to simulate impression transfer. Two implants with external hexagon and regular platform 4.1 mm (φ = 3.75 &#215; 10 mm) were adapted and screwed into the copings (3i, Implant Innovation Inc., Palm Beach Gardens, Florida, EUA). To obtain the photoelastic model, the plaster model was duplicated using photoelastic resin (PL-2 Vishay; Micro-Measurements Group, Inc., Raleigh, NC, USA) to give the impression that the implants were incorporated.</p><p>Four models of overdentures with different attachments were assessed (<xref ref-type="fig" rid="fig1">Figure 1</xref>). The attachment systems used were: Model A: O-ring (O) (Conex&#227;o Systems Prosthodontics, S&#227;o Paulo, SP, Brazil); Model B: ERA (E) (Sterngold Implamed, Attleboro, MA, USA); Model C: Bar-clip (BC) (Conex&#227;o Systems Prosthodontics, S&#227;o Paulo, SP, Brazil) and Model D: Bar-clip associate O-ring (BCO) (Conex&#227;o Systems Prosthodontics, S&#227;o Paulo, SP, Brazil). The bar systems BC and BCO were fabricated under the photoelastic model with 2 mm of distance in the bar/model interface. In the model BCO, the bar was splinted with two distal O-ring attachments (Conex&#227;o Systems Prosthodontics, S&#227;o Paulo, SP, Brazil). The bars were used according the instructions of the LiteCast NiCr metal league supplier (Williams Advanced Materials, Buffalo, NY, USA).</p><p>Four overdentures with the same artificial teeth position were made. Tostandardize, the first over denture was duplicated withl aboratory silicone (Silibor, Artigos Odontol&#243;gicos Cl&#225;ssico Ltda., S&#227;o Bernardo do Campo, SP, Brazil). This mold allowed the same teeth position and similar thickness of the denture base, respecting the relief for each attachment system.</p><p>To simulate the mucosa thickness, 1 mm Coe-Soft (GC Am&#233;rica, Alsip, IL, USA) was incorporate over the prosthesis, between the denture base and the photoelastic model. This resilience has a significance influence on stress distribution of the implants and cannot be ignored.</p><p>To verify the quality of photoelastic models as well the attachments bar passivity, all of the samples were analyzed on the polariscope to accuse residual stress. At the center of the polariscope, overdentures were loaded with a universal mechanical testing machine (Emic, S&#227;o Jos&#233; dos Pinhais, PR, Brazil). The axial compressive load was 10 kgf (100N) and 0.5 mm/s applied on the anterior region between the central incisors, posterior region in the mesial fossa region of the second premolar and central fossa of the second molar. Each point was in-</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Attachment systems. (A) O-ring; (B) ERA; (C) Bar-clip; (D) Bar-clip/O-ring</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7701631x6.png"/></fig><p>dividually loaded and the stresses patterns for each region were captured by photo (Nikon D70 105 mm macro lens-Nikon Corp, Minato-Ku, Tokyo, Japan) with images obtained at static position. The results were evaluated qualitatively through the counting of isochromatic fringes. The higher the number of fringes, the more stress was concentrated on the region.</p></sec><sec id="s3"><title>3. Results</title><sec id="s3_1"><title>3.1. Anterior Load</title><p>In the present study, a difference between treatments was observed (<xref ref-type="fig" rid="fig2">Figure 2</xref>). The attachment systems O-ring and ERA transferred part of the stress to the anterior the region of alveolar ridge, while the bar models did not show stress in the anterior alveolar ridge. The apical region of the implants showed a greater number of fringes corresponding to a higher magnitude of stress. However, the bars system exhibited higher stress on the cervical third of the implant. The O-ring attachment exhibited lower numbers of fringes on the apical region of implant followed by the ERA. The anterior load did not show stress in the posterior alveolar ridge in all situations, but the distal alveolar crest region of implants on O-ring attachment showed higher concentrations of stress.</p></sec><sec id="s3_2"><title>3.2. Premolar Load</title><p>After loading on the mesial fossa of second premolar, the anterior alveolar ridge showed lower stress. For all the models, the ipsilateral implants showed higher number of fringes when compared to the contralateral implants. For the bar systems (BC and BCO), the implants showed more number of fringes than the O and E models (<xref ref-type="fig" rid="fig3">Figure 3</xref>). The model with the O-ring attachment resulted in lower stress on the implants and greater stress on the alveolar posterior ridge. The model ERA attachment exhibited a higher number of fringes in the implants, when compared to the O-ring; however, ERA exhibited a smaller number than the attachment systems BC and BCO. The BC model showed higher stress in the implants and regular distribution on the posterior alveolar ridge, whereas the BCO model showed the highest number of fringes in the implants, but the lowest stress on the alveolar ridge (<xref ref-type="fig" rid="fig4">Figure 4</xref>).</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Isochromatic fringes in the anterior support areas</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7701631x7.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Isochromatic fringes in the anterior support areas on the premolar loading</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7701631x8.png"/></fig></sec><sec id="s3_3"><title>3.3. Molar Load</title><p>The loading in the molar, stresses were not observed in the anterior ridge. The O-ring model showed few fringe in the implant when compared to the ERA attachment system. For the models with bar (BC and BCO), the BCO exhibited the higher number of fringes on implant region. Due to lower stress on implants, the O-ring attachment showed higher stress on the posterior alveolar ridge, followed by ERA, BC, and BCO models, which showed lowest number of fringes on alveolar ridge (<xref ref-type="fig" rid="fig5">Figure 5</xref>).</p></sec></sec><sec id="s4"><title>4. Discussion</title><p>According to the McGill consensus [<xref ref-type="bibr" rid="scirp.58598-ref16">16</xref>] , the use of two implants for overdentures should become the first choice of treatment for an edentulous mandible, improving the quality of life of patients [<xref ref-type="bibr" rid="scirp.58598-ref17">17</xref>] . The bone preservation depends on the occlusal forces that are transmitted to the bone; it is preferable that the attachment systems provide greater balance in stress distribution [<xref ref-type="bibr" rid="scirp.58598-ref18">18</xref>] .</p><p>However, there is no consensus about the best type of attachment system for overdentures implant retained. Some authors [<xref ref-type="bibr" rid="scirp.58598-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref19">19</xref>] showed no clinical difference among the attachments systems over the time. However, most studies evaluated different retention systems clinically, comparing only the ball and bar attachment systems.</p><p>The choice of attachment systems for overdentures depends on several factors, among them retention, which is considered an important criterion, but also should take into consideration stress distribution [<xref ref-type="bibr" rid="scirp.58598-ref20">20</xref>] . In this sense, biomechanical analysis as the photoelastic method has been used to elucidate possible doubts relative to stress distribution [<xref ref-type="bibr" rid="scirp.58598-ref21">21</xref>] . The hypothesis tested by study was rejected, since it observed difference in stress distribution among different attachment systems in overdentures.</p><p>This different results in the attachment systems have been reported by others authors [<xref ref-type="bibr" rid="scirp.58598-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref23">23</xref>] . The</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Isochromatic fringes in stress distribution in the anterior/posterior support areas on the premolar loading</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7701631x9.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Isochromatic fringes in stress distribution in the anterior/posterior support areas on the molar loading</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-7701631x10.png"/></fig><p>unsplinted attachments, such as the O-rings and ERA attachments, showed better stress distribution along the alveolar ridge and implants [<xref ref-type="bibr" rid="scirp.58598-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref24">24</xref>] . The lower stress observed by O-ring may have been influenced because of the modulus of elasticity of the resilient rubber ring inside the capsule which can absorb part of the load [<xref ref-type="bibr" rid="scirp.58598-ref12">12</xref>] .</p><p>Overdentures splinted by a bar attachment showed higher stress, including on the contralateral implants [<xref ref-type="bibr" rid="scirp.58598-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref24">24</xref>] . This may be clinically identified, because the implants showed lightly shallower probing depths around the implants compared to that of the bar attachment system [<xref ref-type="bibr" rid="scirp.58598-ref25">25</xref>] .</p><p>However, some studies reported that the bar attachment system showed more retention for the mandibular overdentures than without bar attachment [<xref ref-type="bibr" rid="scirp.58598-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref27">27</xref>] , being indicated for cases with little retention. Moreover, the bar attachment systems need less maintenance in relation to the O-ring attachment [<xref ref-type="bibr" rid="scirp.58598-ref28">28</xref>] .</p><p>Another factor to be taken into considerations is intermaxillary space for the attachment systems, because is necessary that the minimum space is under the bar, to favor access for cleaning and avoiding what may cause a soft tissue inflammatory response [<xref ref-type="bibr" rid="scirp.58598-ref19">19</xref>] .</p><p>Considering the influence of stress distribution, the O-ring retention system showed smaller stresses which clip O-ring association. Nevertheless, for this attachment is recommended the parallelism between implants [<xref ref-type="bibr" rid="scirp.58598-ref29">29</xref>] as used in this study, fact that may have influenced for the greater results is in the O-ring model. All isolated systems agree to literature findings [<xref ref-type="bibr" rid="scirp.58598-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.58598-ref24">24</xref>] that attribute better stress distribution in these situations. The ERA attachment transfers stress for the contralateral implant when the overdentures were in displacement, and this factor can represent important clinical significance during the function.</p><p>The association of two attachment systems can be used in cases that are necessary for improving the stability and retention of prosthesis, due to the number or position of the implants. However, stress distribution in the attachment systems is not favorable, as observed in the literature [<xref ref-type="bibr" rid="scirp.58598-ref12">12</xref>] .</p><p>Although the data compared in this study show different stress distributions across each situation, the clinical decision needs more scientific support, mainly due to the unknown level of physiologically tolerance.</p><p>The limitations of this study include the resin used for simulating the bone that presents differences when compared with real tissue [<xref ref-type="bibr" rid="scirp.58598-ref30">30</xref>] , and assumes all the structures are isotropic and homogeneous [<xref ref-type="bibr" rid="scirp.58598-ref31">31</xref>] . Thus, the results observed in this studied should be analyzed with caution for each case in particular, it may help clinicians to define the best of attachment systems.</p></sec><sec id="s5"><title>5. Conclusion</title><p>Considering the limitations of this study in vitro can conclude that the isolated attachment systems are used for more equal distribution when compared to the bar attachment systems that transmit higher stress levels to the peri-implant area.</p></sec><sec id="s6"><title>Cite this paper</title><p>EduardoVedovatto,Jose Vitor QuinelliMazaro,Humberto GennariFilho,Paulo S&#233;rgio Perri deCarvalho,Caroline Cantieri deMello,Cleidiel Aparecido AraujoLemos, (2015) Biomechanical Analysis of Implant Assisted-Overdentures with Variations in the Attachments Systems. Materials Sciences and Applications,06,734-742. doi: 10.4236/msa.2015.68075</p></sec><sec id="s7"><title>Abbreviations</title><p>O-ring = (O)</p><p>ERA = (E)</p><p>Bar-clip = (BC)</p><p>Bar-clip associate O-ring = (BCO)</p></sec><sec id="s8"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.58598-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Cunha, T.R., Della Vecchia, M.P., Regis, R.R., Ribeiro, A.B., Muglia, V.A., Mestriner Jr., W., et al. (2013) A Randomised Trial on Simplified and Conventional Methods for Complete Denture Fabrication: Masticatory Performance and Ability. Journal of Dentistry, 41, 133-142. http://dx.doi.org/10.1016/j.jdent.2012.09.008</mixed-citation></ref><ref id="scirp.58598-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Pennington, J. and Parker, S. (2012) Improving Quality of Life Using Removable and Fixed Implant Prostheses. Compendium of Continuing Education in Dentistry, 33, 268-276.</mixed-citation></ref><ref id="scirp.58598-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Goiato, M.C., Ribeiro, P.P., Garcia, A.R. and dos Santos, D.M. (2008) Complete Denture Masticatory Efficiency: A Literature Review. Journal of the California Dental Association, 36, 683-686.</mixed-citation></ref><ref id="scirp.58598-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Taguchi, A., Sanada, M., Suei, Y., Ohtsuka, M., Lee, K., Tanimoto, K., et al. (2004) Tooth Loss Is Associated with an Increased Risk of Hypertension in Postmenopausal Women. Hypertension, 43, 1297-1300.  
http://dx.doi.org/10.1161/01.HYP.0000128335.45571.ce</mixed-citation></ref><ref id="scirp.58598-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Abnet, C.C., Qiao, Y.L., Dawsey, S.M., Dong, Z.-W., Taylor, P.R. and Mark, S.D. (2005) Tooth Loss Is Associated with Increased Risk of Total Death and Death from Upper Gastrointestinal Cancer, Heart Disease, and Stroke in a Chinese Population-Based Cohort. International Journal of Epidemiology, 34, 467-474.  
http://dx.doi.org/10.1093/ije/dyh375</mixed-citation></ref><ref id="scirp.58598-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Semba, R.D., Blaum, C.S., Bartali, B., Xue, Q.L., Ricks, M.O., Guralnik, J.M., et al. (2006) Denture Use, Malnutrition, Frailty, and Mortality among Older Women Living in the Community. The Journal of Nutrition, Health and Aging, 10, 161-167.</mixed-citation></ref><ref id="scirp.58598-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Cakir, O., Kazancioglu, H.O., Celik, G., Deger, S. and Ak, G. (2014) Evaluation of the Efficacy of Mandibular Conventional and Implant Prostheses in a Group of Turkish Patients: A Quality of Life Study. Journal of Prosthodontics, 23, 390-396. http://dx.doi.org/10.1111/jopr.12120</mixed-citation></ref><ref id="scirp.58598-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Dias, R., Moghadam, M., Kuyinu, E. and Jahangiri, L. (2013) Patient Satisfaction Survey of Mandibular Two-Implant-Retained Overdentures in a Predoctoral Program. The Journal of Prosthetic Dentistry, 110, 76-81.  
http://dx.doi.org/10.1016/S0022-3913(13)60343-1</mixed-citation></ref><ref id="scirp.58598-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Zafiropoulos, G.G. and Hoffman, O. (2011) Implant-Retained Dentures for Full-Arch Rehabilitation: A Case Report Comparing Fixed and Removable Restorations. General Dentistry, 59, e137-e143.</mixed-citation></ref><ref id="scirp.58598-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Chee, W. and Jivraj, S. (2006) Treatment Planning of the Edentulous Mandible. British Dental Journal, 201, 337-347.  
http://dx.doi.org/10.1038/sj.bdj.4814041</mixed-citation></ref><ref id="scirp.58598-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Sadowsky, S.J. (2001) Mandibular Implant-Retained Overdentures: A Literature Review. Journal of Prosthetic Dentistry, 86, 468-473. http://dx.doi.org/10.1067/mpr.2001.119921</mixed-citation></ref><ref id="scirp.58598-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Machado, A.C., Cardoso, L., Brandt, W.C., Henriques, G.E.P. and de Arruda Nóbilo, M.A. (2011) Photoelastic Analysis of the Distribution of Stress in Different Systems of Overdentures on Osseous-Integrated Implants. Journal of Craniofacial Surgery, 22, 2332-2336. http://dx.doi.org/10.1097/SCS.0b013e318232a791</mixed-citation></ref><ref id="scirp.58598-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Jacques, L.B., Moura, M.S., Suedam, V., Souza, E.A.Z. and Rubo, J.H. (2009) Effect of Cantilever Length and Frame-work Alloy on the Stress Distribution of Mandibular-Cantilevered Implant-Supported Prostheses. Clinical Oral Implants Research, 20, 737-741. http://dx.doi.org/10.1111/j.1600-0501.2009.01712.x</mixed-citation></ref><ref id="scirp.58598-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Van Kampen, F.M., van der Bilt, A., Cune, M.S., Fontijn-Tekamp, F.A. and Bosman, F. (2004) Masticatory Function with Implant Supported Overdentures. Journal of Dental Research, 83, 708-711.  
http://dx.doi.org/10.1177/154405910408300910</mixed-citation></ref><ref id="scirp.58598-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Sadowsky, S.J. (2007) Treatment Considerations for Maxillary Implant Overdentures: A Systematic Review. Journal of Prosthetic Dentistry, 97, 340-348. http://dx.doi.org/10.1016/S0022-3913(07)60022-5</mixed-citation></ref><ref id="scirp.58598-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Feine, J.S., Carlsson, G.E., Awad, M.A., et al. (2002) The McGill Consensus Statement on Overdentures. Mandibular Two-Implant Overdentures as First Choice Standard of Care for Edentulous Patients. Gerodontology, 19, 3-4.  
http://dx.doi.org/10.1111/j.1741-2358.2002.00003.x</mixed-citation></ref><ref id="scirp.58598-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Fitzpatrick, B. (2006) Standard of Care for the Edentulous Mandible: A Systematic Review. Journal of Prosthetic Dentistry, 95, 71-78. http://dx.doi.org/10.1016/j.prosdent.2005.11.007</mixed-citation></ref><ref id="scirp.58598-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Federick, D.R. and Caputo, A.A. (1996) Effects of Overdenture Retention Designs and Implant Orientation on Load Transfer Characteristics. Journal of Prosthetic Dentistry, 76, 624-632.  
http://dx.doi.org/10.1016/S0022-3913(96)90441-2</mixed-citation></ref><ref id="scirp.58598-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Naert, I., Alsaadi, G. and Quirynen, M. (2004) Prosthetic Aspects and Patient Satisfaction with Two-Implant-Retained Mandibular Overdentures: A 10-Year Randomized Clinical Study. The International Journal of Prosthodontics, 17, 401-410.</mixed-citation></ref><ref id="scirp.58598-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Celik, G. and Uludag, B. (2014) Effect of the Number of Supporting Implants on Mandibular Photoelastic Models with Different Implant-Retained Overdenture Designs. Journal of Prosthodontics, 23, 374-380.  
http://dx.doi.org/10.1111/jopr.12129</mixed-citation></ref><ref id="scirp.58598-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Pesqueira, A.A., Goiato, M.C., Filho, H.G., et al. (2014) Use of Stress Analysis Methods to Evaluate the Biomechanics of Oral Rehabilitation with Implants. Journal of Oral Implantology, 40, 217-228.  
http://dx.doi.org/10.1563/AAID-JOI-D-11-00066</mixed-citation></ref><ref id="scirp.58598-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Bar&amp;atilde;o, V.A., Delben, J.A., Lima, J., Cabral, T. and Assun&amp;atilde;o, W.G. (2013) Comparison of Different Designs of Implant-Retained Overdentures and Fixed Full-Arch Implant-Supported Prosthesis on Stress Distribution in Edentulous Mandible—A Computed Tomography-Based Three-Dimensional Finite Element Analysis. Journal of Biomechanics, 46, 1312-1320. http://dx.doi.org/10.1016/j.jbiomech.2013.02.008</mixed-citation></ref><ref id="scirp.58598-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Ozan, O. and Ramoglu, S. (2015) Effect of Implant Height Differences on Different Attachment Types and Peri-Im-plant Bone in Mandibular Two-Implant Overdentures: 3D Finite Element Study. Journal of Oral Implantology, 41, e50-e59.</mixed-citation></ref><ref id="scirp.58598-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Trakas, T., Michalakis, K., Kang, K. and Hirayama, H. (2006) Attachment Systems for Implant Retained Overdentures: A Literature Review. Implant Dentistry, 15, 24-34. http://dx.doi.org/10.1097/01.id.0000202419.21665.36</mixed-citation></ref><ref id="scirp.58598-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Cune, M., Burgers, M., van Kampen, F., et al. (2010) Mandibular Overdentures Retained by Two Implants: 10-Year Results from a Crossover Clinical Trial Comparing Ball-Socket and Bar-Clip Attachments. The International Journal of Prosthodontics, 23, 310-317.</mixed-citation></ref><ref id="scirp.58598-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Scherer, M.D., McGlumphy, E.A., Seghi, R.R. and Campagni, W.V. (2013) Comparison of Retention and Stability of Implant-Retained Overdentures Based upon Implant Number and Distribution. The International Journal of Oral &amp; Maxillofacial Implants, 28, 1619-1628. http://dx.doi.org/10.11607/jomi.3067</mixed-citation></ref><ref id="scirp.58598-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Scherer, M.D., McGlumphy, E.A., Seghi, R.R. and Campagni, W.V. (2014) Comparison of Retention and Stability of Two Implant-Retained Overdentures Based on Implant Location. Journal of Prosthetic Dentistry, 112, 515-521.  
http://dx.doi.org/10.1016/j.prosdent.2014.03.003</mixed-citation></ref><ref id="scirp.58598-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Abi Nader, S., de Souza, R.F., Fortin, D., De Koninck, L., Fromentin, O. and Albuquerque Jr., R.F. (2011) Effect of Simulated Masticatory Loading on the Retention of Stud Attachments for Implant Overdentures. Journal of Oral Rehabilitation, 38, 157-164. http://dx.doi.org/10.1111/j.1365-2842.2010.02145.x</mixed-citation></ref><ref id="scirp.58598-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Karabuda, C., Yaltirik, M. and Bayraktar, M. (2008) A Clinical Comparison of Prosthetic Complications of Implant-Supported Overdentures with Different Attachment Systems. Implant Dentistry, 17, 74-81.  
http://dx.doi.org/10.1097/ID.0b013e318166d88b</mixed-citation></ref><ref id="scirp.58598-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Berg, T. and Caputo, A.A. (1993) Maxillary Distal-Extension Removable Partial Denture Abutments with Reduced Periodontal Support. Journal of Prosthetic Dentistry, 70, 245-250. http://dx.doi.org/10.1016/0022-3913(93)90059-W</mixed-citation></ref><ref id="scirp.58598-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Pigozzo, M.N., Laganá, D.C., Sesma, N., et al. (2014) Photoelastic Stress Analysis in Mandibular Bone Surrounding Bar-Clip Overdenture Implants. Brazilian Oral Research, 28, pii: S1806-83242013005000034</mixed-citation></ref></ref-list></back></article>