<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JMP</journal-id><journal-title-group><journal-title>Journal of Modern Physics</journal-title></journal-title-group><issn pub-type="epub">2153-1196</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jmp.2015.68111</article-id><article-id pub-id-type="publisher-id">JMP-58181</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Optical Properties of Silver Nanoparticles for Surface Plasmon Resonance (SPR)-Based Biosensor Applications
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ufsyi</surname><given-names>Mahmudin</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Edi</surname><given-names>Suharyadi</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Agung</surname><given-names>Bambang Setio Utomo</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kamsul</surname><given-names>Abraha</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Department of Physics, Universitas Gadjah Mada, Yogyakarta, Indonesia</addr-line></aff><aff id="aff1"><addr-line>Department of Physics, Universitas Tadulako, Palu, Indonesia</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>esuharyadi@ugm.ac.id(ES)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>10</day><month>07</month><year>2015</year></pub-date><volume>06</volume><issue>08</issue><fpage>1071</fpage><lpage>1076</lpage><history><date date-type="received"><day>1</day>	<month>June</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>19</month>	<year>July</year>	</date><date date-type="accepted"><day>22</day>	<month>July</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  It has been successfully carried out the synthesis of silver nanoparticles by chemical reduction method. Silver nitrate (AgNO
  <sub>3</sub>) is used as the metal precursor and trisodium citrate as the reducing agent as well as the use of polyvinyl alcohol (PVA) as a stabilizer. The formation of silver nanoparticles was observed visually with discoloration (yellow). To excite surface plasmons, attenuated total reflection (ATR) method is used with Krestchmann configuration of the prism coupling. The maximum absorption band in the UV-Vis spectrometer shows a red shift of 429.43 nm wavelength for a colloidal solution of silver nanoparticles without PVA and 429.01 nm with PVA. The addition of PVA sharpened absorption spectrum curve and produce a broad absorption band which is indicative of a smaller particle size. TEM images showed that the morphology (crystallites) silver nanoparticles have nearly spherical geometry with dispersive particle distribution. Dispersibility of nanoparticles such as this could potentially be used as an active ingredient of SPR biosensor. The observation of the SPR phenomenon shows the SPR angle shift of 0.1&#176; when a thin layer of silver as an active ingredient a biosensor coated with silver nanoparticles and 0.2&#176; when silver nanoparticles with PVA. SPR angle shift and increase the reflectance values caused by changes in surface Plasmon, which can be a reference that the SPR phenomenon with the sensing surface modification using an additional layer of silver nanoparticles can increase sensitivity.
 
</p></abstract><kwd-group><kwd>Chemical Reduction</kwd><kwd> Silver Nanoparticles</kwd><kwd> Surface Plasmon</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Biosensor based surface plasmon resonance (SPR) is a type of optical sensor that utilizes surface plasmon polariton (SPP) waves. Utilization of SPR as biosensors to monitor and provide information about biological processes shows very promising results especially in studying biomolecular interactions. SPR-based biosensor is very sensitive and responsive to changes in the refractive index of the analyte, so biosensors of this type can be used to detect the presence of biomolecules with biorecognition element which is used as the material of the analyte in the form of DNA [<xref ref-type="bibr" rid="scirp.58181-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.58181-ref2">2</xref>] , protein [<xref ref-type="bibr" rid="scirp.58181-ref3">3</xref>] [<xref ref-type="bibr" rid="scirp.58181-ref4">4</xref>] , enzymes [<xref ref-type="bibr" rid="scirp.58181-ref5">5</xref>] , antibodies [<xref ref-type="bibr" rid="scirp.58181-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.58181-ref7">7</xref>] and peptides [<xref ref-type="bibr" rid="scirp.58181-ref8">8</xref>] . Meanwhile, in recent years, the noble metal nanoparticles have been the subject of research interest because of its unique properties, such as the electronic properties, optical, mechanical, magnetic and chemical properties are significantly different from the bulk material [<xref ref-type="bibr" rid="scirp.58181-ref9">9</xref>] - [<xref ref-type="bibr" rid="scirp.58181-ref11">11</xref>] . For this reason the noble metal nanoparticles have been widely used in many applications in different fields such as catalysis, electronic and photonic [<xref ref-type="bibr" rid="scirp.58181-ref12">12</xref>] - [<xref ref-type="bibr" rid="scirp.58181-ref14">14</xref>] . One application of noble metal nanoparticles gives you an idea SPR-based biosensor development with the addition of nanoscale structures are designed so that they can run a particular optical function. Based on the phenomenon that is able to manipulate the addition of nanoparticles SPR detection parameters, then the idea of increased SPR performance with the addition of nanoparticles [<xref ref-type="bibr" rid="scirp.58181-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.58181-ref16">16</xref>] .</p><p>The addition of a metal nanoparticle structure allows for very strong coupling between the electron resonances with the light coming simultaneously in metallic nanostructures [<xref ref-type="bibr" rid="scirp.58181-ref17">17</xref>] . Such a mechanism would produce the amplified signal for its ability to propagate waves simultaneously. Research on added above a thin layer of metal nanoparticles has been carried out by Singh, et al. [<xref ref-type="bibr" rid="scirp.58181-ref18">18</xref>] . Singh, et al. (2009) reported that the presence of metal nanoparticles can shift ATR curve of 1.037˚ compared with conventional SPR only shifts the ATR curve at 0.716˚ in the experimental detection of BSA (Bovine Serum Albumin). Wu and Wang (2009) also developed a technique increased sensitivity sensing biomolecules using nanoparticles embedded in SiO<sub>2</sub> matrix [<xref ref-type="bibr" rid="scirp.58181-ref19">19</xref>] . In addition, nanoparticles are selected for the ability to bind the material is very high considering that interacts with a surface area of the material is very wide compared to its bulk phase. With the ability of absorption material is very high, the mobility of the analyte can also be reduced, thus the accuracy and sensitivity of the biosensor will be improved.</p><p>In this study, SPR biosensor based on the conventional SPR models will be developed by adding silver nanoparticles structure on top of a thin layer. The addition of silver nanoparticles is expected to increase the sensitivity of SPR biosensor. In this method, the addition of colloidal silver nanoparticles affects the ATR curves, i.e. the shift of the SPR reflectance angle, extending the curve and an increase in the minimum reflectivity. On the other hand, various methods of preparation of silver nanoparticles have also been reported, such as electrochemical synthesis, ultrasonic irradiation, radiolysis, thermal decomposition and the simplest method is the chemical reduction of metal salts [<xref ref-type="bibr" rid="scirp.58181-ref20">20</xref>] - [<xref ref-type="bibr" rid="scirp.58181-ref23">23</xref>] . For this reason, this study proposes a new method in the synthesis of silver nanoparticles of silver nitrate solution with a reducing agent trisodium citrate and growth of its nanoparticles controlled using stabilizers polyvinyl alcohol. The size, structure and optical properties of the resulting nanoparticles subsequently were characterized by transmission electron microscope (TEM) and UV-Vis spectroscope.</p></sec><sec id="s2"><title>2. Experimental Methods</title><sec id="s2_1"><title>2.1. Experiment</title><p>Silver nitrate (AgNO<sub>3</sub>), trisodium citrate (Na<sub>3</sub>C<sub>6</sub>H<sub>5</sub>O<sub>7</sub>∙2H<sub>2</sub>O, Naci) and polyvinyl alcohol (PVA) was purchased from Sigma Aldrich. The colloidal silver nanoparticles (AgNPs) was prepared by using chemical reduction method. All solutions of reacting materials were prepared in aquadest. In typical experiment 100 ml of 1.10<sup>-3</sup>M AgNO<sub>3</sub> was heated with temperature of 90˚C for 5 minutes. To this solution 10 ml of 0.038 M Naci was added drop by drop with constant stirring at 800 rpm for 10 minutes until it changes color (pale yellow). The solution was heated continuously until the color changes were apparent (yellow). Then the heating is stopped and stirred continuously until cool at room temperature. <xref ref-type="fig" rid="fig1">Figure 1</xref> (inset) shows colloidal silver nanoparticles resulting from the synthesis process. A1 shows colloidal silver nanoparticles were prepared by using Naci, while A2 with added stabilizers Polyvinyl Alcohol (PVA) with AgNO<sub>3</sub>:PVA mass ratio of 1:10.</p></sec><sec id="s2_2"><title>2.2. Characterization</title><p>The reduction of metal ions was monitored by measuring the UV-Vis spectroscopy of the solution. The UV-Vis spectroscopy measurement of silver nanoparticle was recorded on Shimadzu dual beam spectrophotometer (model UV-1650 PC) operated at a resolution of 1 nm. The silver nanoparticle was measured in a wavelength ranging from 350 to 800 nm. The TEM sample was prepared by placing one droplet of the prepared colloid onto a micro grid. A Hitachi H-800 model (voltage 200 kV) was employed for TEM observation.</p></sec><sec id="s2_3"><title>2.3. A Thin Layer Growth and Observations SPR</title><p>Thin film layer of silver (Ag) on the prism surface was fabricated by a vacuum evaporator. As for the deposition of silver nanoparticles use the spray method. To excite surface plasmons, attenuated total reflection (ATR) method is used with Krestchmann configuration the prism coupling.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><p>It has been successfully carried out the synthesis of silver nanoparticles by chemical reduction method. The formation of silver nanoparticles was observed visually with discoloration (yellowish). Yellowish color is formed on the sample indicates that the colloidal nanoparticles produced are the synthesis process is dominated by grains of silver nanoparticles.</p><p>UV-Vis spectrometer is spectral techniques are widely used to confirm the formation and structural characterization of silver nanoparticles in colloidal solution. <xref ref-type="fig" rid="fig1">Figure 1</xref> shows the absorption spectrum of a solution of colloidal silver nanoparticles synthesized by Naci reducing agent and with different treatment. Optical absorption spectra of silver nanoparticles is dominated by surface plasmon which shows a shift towards the red end or blue end depends on particle size, shape, state of aggregation and the surrounding dielectric medium. Absorption band in the visible region is characteristic of silver nanoparticles. Plasmon peak and full width half maximum depends on the extent of aggregation of colloidal occur. <xref ref-type="fig" rid="fig1">Figure 1</xref> shows the surface plasmon absorption band with a maximum of 429.43 nm for the spectrum of colloidal silver nanoparticles were prepared by reducing Naci. The addition of PVA stabilizers have sharpen absorption spectrum curves and occur redshift peak wavelength absorption at a wavelength of 429.01 nm. The addition of PVA also delivers a broad absorption band which is indicative of a smaller particle size.</p><p>The absorption spectrum (<xref ref-type="fig" rid="fig1">Figure 1</xref>) of the pale yellow colloidal silver nanoparticles prepared by Naci reduction showed a surface plasmon absorption band with a maximum of 429.43 nm indicating the presence of spherical or roughly spherical Silver nanoparticles [<xref ref-type="bibr" rid="scirp.58181-ref24">24</xref>] , and TEM imaging confirmed this (<xref ref-type="fig" rid="fig2">Figure 2</xref>). Morphological image in <xref ref-type="fig" rid="fig2">Figure 2</xref> also show that the morphology (crystallites) silver nanoparticles have nearly spherical geometry with particle distribution is quite dispersive although there is a trend going on clotting. Dispersibility of</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> UV-Vis absorption spectra of colloidal silver nanoparticles synthesized and inserted photo synthesized silver nanoparticles</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7502282x6.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> TEM image of colloidal silver nanoparticles with: (a) without stabilizers polyvinyl alcohol (PVA); and (b) with the stabilizer of PVA</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7502282x7.png"/></fig><p>nanoparticles such as this could potentially be used as an active ingredient of SPR biosensor. TEM image also shows that the highest population size of the diameter of the two samples of silver nanoparticles in the range of 8 to 46 nm with an average diameter of the distribution obtained for 29 nm and 21 nm.</p><p>Observations SPR phenomenon in this study using a prism/silver thin film (AgTF)/silver nanoparticles (AgNPs) system with Attennuated Total Reflection (ATR) methods in the Kretschmann configuration. Prisms are used in this research is the BK7 type prism with a refractive index of 1.51. <xref ref-type="fig" rid="fig3">Figure 3</xref> shows the SPR reflectance curve for the prism/AgTF/AgNPs coating system. Silver thin film with the silver nanoparticles results a shift in the SPR angle, as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. Prism/AgTF coating system has SPR angle of 42.80˚ with a reflectance value of 0.445 and a surface plasmon wave number of 1.0113 &#180; 10<sup>7</sup> m<sup>−1</sup>. After a silver thin film coated with silver nanoparticles, the SPR angle shift as far as 0.1˚ to 42.90˚ with reflectance values sharpened be 0.320 and the surface plasmon wave number into 1.0132 &#180; 10<sup>7</sup> m<sup>−1</sup>. Surface plasmon waves number change caused by changes in the dielectric constant due to the addition of a layer of silver nanoparticles on the surface of a silver thin film.</p><p>Meanwhile, the use of stabilizers PVA in the synthesis of colloidal silver nanoparticles led to a shift in the SPR angle as far as 0.2˚ becomes 43.00˚ with reflectance values sharpened at 0.263 and surface plasmon wave number into 1.0151 &#180; 10<sup>7</sup> m<sup>−1</sup>. Surface plasmon waves number change also caused by changes in the dielectric constant due to the mixing of the PVA polymer in a solution of colloidal silver nanoparticles. SPR angle shift and increase the reflectance values caused by changes in surface plasmon waves number caused by changes in dielectric constant. The larger the surface plasmon wave number, the greater the resulting SPR angle. The results of these observations may be a reference to that SPR phenomenon with the sensing surface modification using an additional layer of silver nanoparticles can increase sensitivity.</p></sec><sec id="s4"><title>4. Conclusion</title><p>The synthesis of silver nanoparticles has been successfully carried out by chemical reduction method. The maximum absorption band in the UV-Vis spectrometer shows a red shift wavelength of 429.43 nm for a colloidal solution of silver nanoparticles without PVA and 429.01 nm with PVA. The addition of PVA sharpen absorption spectrum curve and produce a broad absorption band which is indicative of a smaller particle size. TEM images showed that the morphology (crystallites) silver nanoparticles have nearly spherical geometry with dispersive particle distribution. The observation of the SPR phenomenon shows the SPR angle shift of 0.1˚ when a thin layer of silver as an active ingredient a biosensor coated with silver nanoparticles and 0.2˚ when silver nanoparticles with PVA. SPR angle shifts and increases the reflectance values caused by changes in surface Plasmon, which can be a reference that the SPR phenomenon with the sensing surface modification using an additional layer of silver nanoparticles can increase sensitivity.</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> The reflectance curve in SPR observation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/6-7502282x8.png"/></fig></sec><sec id="s5"><title>Acknowledgements</title><p>This research is partly supported by Hibah Penelitian Fundamental (2015) and Hibah Kompetensi (2015), Ministry of Research, Technology and Higher Education, Republik Indonesia.</p></sec><sec id="s6"><title>Cite this paper</title><p>LufsyiMahmudin,EdiSuharyadi,Agung Bambang SetioUtomo,KamsulAbraha, (2015) Optical Properties of Silver Nanoparticles for Surface Plasmon Resonance (SPR)-Based Biosensor Applications. Journal of Modern Physics,06,1071-1076. doi: 10.4236/jmp.2015.68111</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.58181-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Wang, Q., Yang, X. and Wang, K. (2007) Sensors and Actuators, 123, 227-232.  
http://dx.doi.org/10.1016/j.snb.2006.08.012</mixed-citation></ref><ref id="scirp.58181-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Spadavecchia, J., Manera, M.G., Quaranta, F., Siciliano, P. and Rella, R. (2005) Biosensors and Bioelectronics, 21, 894-900. http://dx.doi.org/10.1016/j.bios.2005.02.016</mixed-citation></ref><ref id="scirp.58181-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Pan, S., Xu, J., Shu, Y., Wang, F., Xia, W., Ding, Q., Xu, T., et al. (2010) Biosensors and Bioelectronics, 26, 850-853.  
http://dx.doi.org/10.1016/j.bios.2010.08.007</mixed-citation></ref><ref id="scirp.58181-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Ritzefeld, M. and Sewald, N. (2012) Journal of Amino Acids, 2012, Article ID: 816032.  
http://dx.doi.org/10.1155/2012/816032</mixed-citation></ref><ref id="scirp.58181-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Henn, C., Boettcher, S., Steinbach, A. and Hartmann, R.W. (2012) Analytical Biochemistry, 428, 28-30.  
http://dx.doi.org/10.1016/j.ab.2012.05.024</mixed-citation></ref><ref id="scirp.58181-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Kausaite-minkstimiene, A., Ramanaviciene, A. and Ramanavicius, A. (2009) Analyst, 134, 2051-2057.  
http://dx.doi.org/10.1039/b907315a</mixed-citation></ref><ref id="scirp.58181-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Buhl, A., Page, S., Heegaard, N.H.H., Von Landenberg, P. and Luppa, P.B. (2009) Biosensors and Bioelectronics, 25, 198-203. http://dx.doi.org/10.1016/j.bios.2009.06.037</mixed-citation></ref><ref id="scirp.58181-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Ananthanawat, C., Vilaivan, T., Mekboonsonglarp, W. and Hoven, V.P. (2009) Biosensors and Bioelectronics, 24, 3544-3549. http://dx.doi.org/10.1016/j.bios.2009.05.011</mixed-citation></ref><ref id="scirp.58181-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Evanoff Jr., D.D. and Chumanov, G. (2005) Small, 29634, 1221-1231. http://dx.doi.org/10.1002/cphc.200500113</mixed-citation></ref><ref id="scirp.58181-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Kvítek, O., Siegel, J., Hnatowicz, V. and Svorcík, V. (2013) Journal of Nanomaterials, 2013, 1-15.  
http://dx.doi.org/10.1155/2013/743684</mixed-citation></ref><ref id="scirp.58181-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Jain, P.K., Huang, X., El-Sayed, I.H. and El-Sayed, M.A. (2008) Accounts of Chemical Research, 41, 1578-1586.</mixed-citation></ref><ref id="scirp.58181-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Yan, N., Xiao, C. and Kou, Y. (2010) Coordination Chemistry Reviews, 254, 1179-1218. 
http://dx.doi.org/10.1016/j.ccr.2010.02.015</mixed-citation></ref><ref id="scirp.58181-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Yougen, H., Tao, Z., Pengli, Z. and Rong, S. (2012) Colloid and Polymer Science, 290, 401-409. 
http://dx.doi.org/10.1007/s00396-011-2555-0</mixed-citation></ref><ref id="scirp.58181-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Chen, Y. and Ming, H. (2012) Review Literature and Arts of the Americas, 2, 37-49.</mixed-citation></ref><ref id="scirp.58181-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Agata, R.D., Corradini, R., Ferretti, C., Zanoli, L., Gatti, M., Marchelli, R. and Spoto, G. (2010) Biosensors and Bioelectronics, 25, 2095-2100. http://dx.doi.org/10.1016/j.bios.2010.02.008</mixed-citation></ref><ref id="scirp.58181-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Jiang, G.Q., Baba, A., Ikarashi, H., Xu, R.S., Locklin, J., Kashif, K.R., et al. (2007) The Journal of Physical Chemistry C, 111, 18687-18694. http://dx.doi.org/10.1021/jp075986e</mixed-citation></ref><ref id="scirp.58181-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Berglind, E., Thylen, L. and Liu, L. (2010) IET Optoelectronics, 4, 1-16. http://dx.doi.org/10.1049/iet-opt.2008.0045</mixed-citation></ref><ref id="scirp.58181-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Singh, K.N., Alqudami, A., Subaramanian, A., Sharma, V. and Muralidhar, K. (2009) AIP Conference Proceedings, 1147, 331-338. http://dx.doi.org/10.1063/1.3183453</mixed-citation></ref><ref id="scirp.58181-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Wu, B. and Wang, Q.K. (2009) Optica Applicata, 39, 31-41.</mixed-citation></ref><ref id="scirp.58181-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Pyatenko, A., Yamaguchi, M. and Suzuki, M. (2007) The Journal of Physical Chemistry C, 111, 7910-7917. 
http://dx.doi.org/10.1021/jp071080x</mixed-citation></ref><ref id="scirp.58181-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Ghodselahi, T., Neishaboory, T. and Vesaghi, M.A. (2011) Biosensors, 2, 59-61.</mixed-citation></ref><ref id="scirp.58181-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Tran, Q.H., Nguyen, V.Q. and Le, A. (2013) Advances in Natural Sciences: Nanoscience and Nanotechnology, 4, 1-20. 
http://dx.doi.org/10.1088/2043-6262/4/3/033001</mixed-citation></ref><ref id="scirp.58181-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">El-Nour, K.M.M.A., Al-Warthan, A. and Ammar, R.A.A. (2010) Arabian Journal of Chemistry, 3, 135-140. 
http://dx.doi.org/10.1016/j.arabjc.2010.04.008</mixed-citation></ref><ref id="scirp.58181-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Guzmán, M.G., Dille, J. and Godet, S. (2008) World Academy of Science, Engineering and Technology, 43, 357-364.</mixed-citation></ref></ref-list></back></article>