<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">MSA</journal-id><journal-title-group><journal-title>Materials Sciences and Applications</journal-title></journal-title-group><issn pub-type="epub">2153-117X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/msa.2015.65048</article-id><article-id pub-id-type="publisher-id">MSA-56695</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Optical Properties of Tetrahedral Amorphous Carbon Films and Their Potential for Lab-on-a-Chip
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>atja</surname><given-names>Guenther</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Frank</surname><given-names>Sonntag</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Teja</surname><given-names>Roch</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Andrés</surname><given-names>Fabián Lasagni</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>University of Applied Sciences Mittweida, Mittweida, Germany</addr-line></aff><aff id="aff2"><addr-line>Fraunhofer Institute for Material and Beam Technology IWS, Dresden, Germany</addr-line></aff><aff id="aff3"><addr-line>TU Dresden, Institute of Manufacturing Technology, Dresden, Germany</addr-line></aff><pub-date pub-type="epub"><day>21</day><month>04</month><year>2015</year></pub-date><volume>06</volume><issue>05</issue><fpage>445</fpage><lpage>455</lpage><history><date date-type="received"><day>1</day>	<month>April</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>24</month>	<year>May</year>	</date><date date-type="accepted"><day>27</day>	<month>May</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this study, tetrahedral amorphous carbon (ta-C) films with thicknesses between several 100 nm and several micrometers have been deposited onto polished tungsten carbide and steel substrates by pulsed laser deposition (PLD) using an excimer laser (248 nm wavelength). We investigate the optical properties (e.g. the refractive index (n) and extinction coefficient (k) in the visible and near-infrared wavelength range) of these layers in dependence of the used laser ablation fluence on the target. It is shown that n of ~2000 nm thick ta-C films can be tuned, depending on the sp
  &lt;sup&gt;3
  &lt;/sup&gt;-content, between n = 2.5 and 2.8 at a wavelength of 632 nm. Besides of this k reduces with the sp
  &lt;sup&gt;3
  &lt;/sup&gt;-content and is as low as 0.03 at sp&lt;sup&gt;3&lt;/sup&gt;-contents of more than 75%. We proof that this gives the opportunity to prepare coating with tailored optical properties. Furthermore, it is shown that the ta-C films have low background fluorescence in the wavelengths range of 380 - 750 nm, which make this thin films attractive for certain optical, medical and biotechnological applications. We present for the first time that one possible application is the use in Lab-on-a-Chip-systems (LOC). Within these systems, the ultrasensitive detection of fluorescence markers and dyes is a challenge. In order to increase the signal-to-noise-ratio, a setup was developed, that used the specific optical properties of ta-C films produced by PLD. We used the ta-C film as an integrated reflector that combined low background fluorescence, a low reflectivity at the excitation wavelength and the high reflectivity at the emission wavelength. We prove that this setup improves the detection of fluorescence photons.
 
</p></abstract><kwd-group><kwd>Tetrahedral Amorphous Carbon</kwd><kwd> Pulsed Laser Deposition</kwd><kwd> Thin Films</kwd><kwd> Diamond-Like Carbon</kwd><kwd> Lab-on-a-Chip</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Diamond-like carbon films (DLC), especially the group of super-hard, hydrogen-free amorphous carbon films (ta-C) with a high content of tetrahedral bonding, are used in a lot of industrial applications, actually. Most applications like wear protection, anti-corrosion and friction reduction of tools and machine parts benefit from the mechanical properties of the ta-C films, like a high hardness in the range of 40 - 90 GPa [<xref ref-type="bibr" rid="scirp.56695-ref1">1</xref>] and a high Young’s modulus in the range of 200 - 820 GPa [<xref ref-type="bibr" rid="scirp.56695-ref1">1</xref>] as well as low coefficients of friction in the range of 0.1 - 0.2 [<xref ref-type="bibr" rid="scirp.56695-ref2">2</xref>] -[<xref ref-type="bibr" rid="scirp.56695-ref5">5</xref>] .</p><p>Applications in biology or optics benefit from the high biocompatibility (e.g. biosensor applications [<xref ref-type="bibr" rid="scirp.56695-ref6">6</xref>] ) and characteristic reflectivity of the ta-C films (e.g. anti-reflection coating [<xref ref-type="bibr" rid="scirp.56695-ref7">7</xref>] ).</p><p>For ta-C thin film deposition it is well known, that the energy of the film forming species influences the content of tetrahedral bindings (sp<sup>3</sup>-fraction). The physical properties of ta-C films depend mainly on the sp<sup>3</sup>-frac- tion. An increase of the sp<sup>3</sup>-content causes an increase of hardness, elasticity modulus and simultaneously an increase in transparency in the visible and near infrared range (e.g. [<xref ref-type="bibr" rid="scirp.56695-ref5">5</xref>] [<xref ref-type="bibr" rid="scirp.56695-ref7">7</xref>] -[<xref ref-type="bibr" rid="scirp.56695-ref9">9</xref>] ).</p><p>There are already different publications on the optical properties of ta-C. Exemplary Tay et al. [<xref ref-type="bibr" rid="scirp.56695-ref10">10</xref>] have measured the optical properties of ta-C films deposited onto silicon substrates using ion energies between 35 and 195 eV. These ta-C films exhibit refractive indices (n) between 2.4 and 2.9 and an extinction coefficient (k) between nearly 0 and 0.25 in a wavelength range of about 200 to 900 nm. The optical energy-gap varied between 2.1 and 2.6 eV [<xref ref-type="bibr" rid="scirp.56695-ref10">10</xref>] .</p><p>Additionally Mathioudakis et al. [<xref ref-type="bibr" rid="scirp.56695-ref8">8</xref>] presented calculations onto the relation between disorder, sp<sup>3</sup>-content and optical properties inamorphous carbon films. They calculated avariation of the optical band gap between nearly 0 and 5 eV in dependence on the sp<sup>3</sup>-fraction. According to Patsalas [<xref ref-type="bibr" rid="scirp.56695-ref7">7</xref>] DLC-films with increased sp<sup>3</sup>-fraction have also an increased density (1.8 to nearly 3.3 g/cm<sup>3</sup>).</p><p>Furthermore Panwar [<xref ref-type="bibr" rid="scirp.56695-ref11">11</xref>] -[<xref ref-type="bibr" rid="scirp.56695-ref13">13</xref>] analyzed the influences of substrate bias, hydrogen and nitrogen content onto the reflectance, the photoluminescence and the sp<sup>3</sup>/sp<sup>2</sup>-ratio. The seta-C-, ta-C:N- and ta-C:H-films were deposited by an S-bend filtered cathodic vacuum arc process. Ta-C films produced with this method show no interference effects in the wavelength range 300 - 600 nm. The reflectance values vary between 10% - 50% [<xref ref-type="bibr" rid="scirp.56695-ref11">11</xref>] .</p><p>It is well known, that ta-C films can be produced using different PVD-methods like S bend filtered cathodic arc [<xref ref-type="bibr" rid="scirp.56695-ref11">11</xref>] -[<xref ref-type="bibr" rid="scirp.56695-ref13">13</xref>] , pulsed laser vacuum arc [<xref ref-type="bibr" rid="scirp.56695-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.56695-ref9">9</xref>] or pulsed laser deposition (PLD) [<xref ref-type="bibr" rid="scirp.56695-ref14">14</xref>] . PLD has the advantage of low droplet formation in comparison to e.g. an arc process as well as a good controllability of the energy of the film forming species.</p><p>One possible optical application for ta-C films is the integration onto Lab-on-a-Chip systems (LOC). LOC systems offer a high degree of integration, miniaturization, automation and the realization of complex processes. The potential of LOC systems is growing in many areas of biotechnology and medical engineering [<xref ref-type="bibr" rid="scirp.56695-ref15">15</xref>] [<xref ref-type="bibr" rid="scirp.56695-ref16">16</xref>] . Basically all LOC systems consist of an immobilized biological component (e.g. DNA, antibodies, enzymes, cells) at the edge of a transducing device like electrodes or optical components like transparent windows or wave guides. The biggest advantage of optical measurements is the ability to detect low quantities of target molecules without direct probe contact. Among those photometric detection approaches fluorescence measurement is the most common method. One reason is the wide range of fluorescent dyes that allow the detection of target molecules at almost any wavelength from UV up to near infrared. Moreover only small sample volumes are needed. Nevertheless in most cases fluorescence dyes are designed for special excitation wavelengths, which are available in almost any fluorescence microscope, flow cytometer or plate reader. Using these benefits of fluorescence many LOC applications were built up in the past [<xref ref-type="bibr" rid="scirp.56695-ref17">17</xref>] . Thereby, the ultra-sensitive detection of fluorescence markers and of dyes is one challenge in LOC applications. Nevertheless still an open issue is to increase photoluminescence efficiency and a reduction of the signal to noise ratio.</p><p>In this study we want to present an approach where ta-C is discussed as a dispersive reflector in LOC. To gain an extended understanding of the optical properties of the ta-C films deposited by PLD, we investigated the influence of the thin film substrates. Further investigations are made about the influence of the laser ablation fluence during film deposition and the deposited ta-C-film thickness onto the optical properties of ta-C.</p><p>Based on these results a setup will be shown, which uses the special optical properties of an integrated ta-C thin film reflector. This setup increases the signal-to-noise-ratio in a LOC system. Such an integrated ta-C film based reflector combines low background fluorescence, low reflectivity at the excitation wavelength and high reflectivity at the emission wavelength. Therefore we investigate the rising of the sensitivity of fluorescence measurements by using biocompatible ta-C films onto polished steel or tungsten carbide substrates as reflector.</p></sec><sec id="s2"><title>2. Material and Methods</title><sec id="s2_1"><title>2.1. PLD Deposition of ta-C Films</title><p>The analyzed ta-C layers were mainly prepared by using the PLD method. Some films were deposited using a combination of PLD and pulsed laser annealing (also known as laser stress relaxation or LSR), the latter resulting in stress relaxation. The experimental set-up is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><p>The ta-C films have been prepared onto steel and tungsten carbide substrates possessing an average roughness (Ra) below 10 nm and maximum dimensions of 40 mm diameter and 5 mm thickness. In comparison to steel, tungsten carbide is robust against disinfection and autoclaving.</p><p>In order to ensure good adhesion of the ta-C layers, the substrates have been cleaned in an ethanol ultrasonic bath up to 5 min before placing them into a high vacuum chamber. In a second step the substrates have been bombarded with an argon ion beam produced in a Kaufmann ion source immediately prior to the deposition in the vacuum chamber (1 min, 10<sup>−2</sup> Pa working pressure, 700 eV ion energy and nearly 150 μA/cm<sup>2</sup> current density onto the substrate). Additionally an 80 nm thick tungsten carbide adhesion layer was prepared by PLD. Therefore a Krypton fluoride excimer (KrF) laser (248 nm wavelength; 25 ns pulse duration, max. 1 J pulse energy, up to 50 Hz pulse repetition rate) operating with an unstable resonator was used for the ablation of a tungsten carbide target by utilizing ablation fluences of 12 J/cm<sup>2</sup> onto the target surface.</p><p>The same laser was used for the ablation of a graphite target, i.e. for the deposition of the ta-C films. The ta-C films have been prepared using various laser fluences in the range of 2 - 22 J/cm<sup>2</sup> for the graphite target ablation. The stress relaxation was made by using LSR every 100 nm Sublayer. The used LSR-laser was a second KrF laser (as described before) but operating with a stable resonator. The annealing was performed with a laser pulse fluences of about 90 mJ/cm<sup>2</sup> and a maximum number of laser pulses per unit area of about 200. Using the LSR method nearly stress-free, super-hard ta-C films with thicknesses of several micrometers can be prepared. The residual gas pressure during deposition was 1 &#215; 10<sup>−4</sup> Pa. The maximum temperature at the substrate was below 100˚C and no substrate bias was added. The entire process and further details can be found in Ref. [<xref ref-type="bibr" rid="scirp.56695-ref14">14</xref>] .</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Experimental set-up used for the preparation of the ta-C films</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x6.png"/></fig><p>Using PLD without LSR the stress of a 2000 nm ta-C film up to 10 GPa. Using the combination of PLD and LSR it is possible to reduce the internal stress to nearly 0 GPa of such a ta-C film. In this work ta-C films which were produced with PLD show internal stresses between 8 - 10 GPa and those which were produced with PLD and LSR show internal stress between 0 - 2 GPa.</p></sec><sec id="s2_2"><title>2.2. Thin Film Characterization Methods</title><p>The surface roughness and the film thickness were measured using a profilometer DEKTAK 3030 from Veeco instruments. In that case the film thickness was measured at a film-edge.</p><p>The refractive index (n), the absorption index (k) and the reflectivity (R) of the coated substrates were investigated using the spectrometer F20 from Filmmetrics and the software “FILMeasure”. The reflectance measurements were carried out by irradiating the substrates with wavelengths in the range between 380 - 1050 nm vertical to the substrate surface (angle of incidence 0˚).</p><p>The internal stress of the ta-C films was measured once in situ using a position sensitive detector and twice ex situ using a surface profilometer. Both methods measure the deflection of a thin silicon wafer, which was inserted into the vacuum chamber next to the substrate. With the Stoney equation the internal stress of the ta-C films deposited onto the silicon substrate was calculated.</p><p>The sp<sup>3</sup>/sp<sup>2</sup>-content was calculated using databased on nano-indentation-hardness-measurements (10 mN loads) and LaWavemeasurement.</p></sec><sec id="s2_3"><title>2.3. Lab-on-a-Chip Device</title><p>The fluorescence measurements were performed by a microscope (Zeiss LSM5 Pascal, light source: Zeiss HBO100, filter set: 9 and 15, detector: CCD camera) and a compact system developed by Fraunhofer Institute of Applied Optics and Precision Engineering IOF in cooperation with Fraunhofer Institute for Material and Beam Technology IWS [<xref ref-type="bibr" rid="scirp.56695-ref17">17</xref>] . For the excitation a high power LED with filter 479 &#177; 20 nm, 531 &#177; 20 nm or 585 &#177; 20 nm where integrated into a microscope similar optical system and used as the light source. The excitation wavelength is separated from the fluorescence signal by a filter 524 &#177; 20 nm, 641 &#177; 38 nm or 628 &#177; 20 nm. For the detection of the fluorescence signal a photomultiplier (Hamamatsu H10723-20) with adjustable amplification was used [<xref ref-type="bibr" rid="scirp.56695-ref17">17</xref>] .</p><p>The fluorescenceirradiation is emitted nearly isotropic in all spatial directions. A sensitive detection system was used to record data of a wide dihedral angle. The optical system works with a high numerical aperture (NA) and thus an aspherical front lens (NA ~ 0.5) is used. The optical imaging shows illuminated channels (analyzed volume) with a maximum width of 0.5 mm (<xref ref-type="fig" rid="fig2">Figure 2</xref>). To increase the sensitivity of the fluorescencesignal, at the up side of the analyzed volume should be a cover (reflector), which reflects the emitted fluorescenceirradiation in direction of the detector (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p><p>The reflector should possess the following properties:</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Schematic sketch of the real fluorescence-measurement-system-setup</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x7.png"/></fig><p>- High biocompatibility (no toxicity for human cells and no immune reaction);</p><p>- Low fluorescence at the used excitation wavelength;</p><p>- Low reflectivity of the used excitation wavelength;</p><p>- High reflectivity of the generated emission wavelength.</p></sec></sec><sec id="s3"><title>3. Theory</title><p>The following optical analyses are based on the physical effect of thin film interference. Considering a homogeneous thin film the transmission T depends on the film thickness (d) and the absorption coefficient (α). This dependence is described by the Lambert-Beer-Law (T = exp(−α∙d)). However, if α∙d &gt; 1 multiple reflections of the light within the thin film might occur. In this case the light reflected at the front surface of the ta-C interacts with light within the thin film. Thus the light can interfere either constructively, increasing the reflection or destructively, increasing the film absorption. This thin film interference depends on the phase difference of both light waves and is determined by the wavelength λ and the optical path length in the thin film.</p><p>It is well known, that the optical path length in the thin film depends on the layer thickness d, the refractive index n and the angle of incident. The position of constructive and destructive interference varies according to [<xref ref-type="bibr" rid="scirp.56695-ref18">18</xref>] :</p><p>Constructive interference:<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/10-7701579x8.png" xlink:type="simple"/></inline-formula> (1)</p><p>Destructive interference:<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/10-7701579x9.png" xlink:type="simple"/></inline-formula> (2)</p><p>Formula (1) and Formula (2) are valid on the following terms:</p><p>- Measurements are undertaken in air. n of air is presumed with the value 1;</p><p>- n of the substrate has higher values than the film;</p><p>- The surface is irradiated perpendicularly;</p><p>- The layer is smooth and has a homogeneous thickness.</p></sec><sec id="s4"><title>4. Results and Discussion</title><sec id="s4_1"><title>4.1. Optical Properties of the Substrates</title><p>Because of the low Ra &lt; 10 nm, the analyzed tungsten carbide substrates possess a nearly constant R of about nearly 44% in the specified measurement range (380 - 1050 nm). The R of the steel substrate is comparable higher (R = 64%). Hence these substrates are useful for optical investigations based on interference effects of ta-C films.</p></sec><sec id="s4_2"><title>4.2. Influence of the Used Ablation Fluence onto the Optical Properties of ta-C Films</title><p><xref ref-type="fig" rid="fig3">Figure 3</xref> shows the measured R of ~2000 nm thick ta-C films deposited onto tungsten carbide substrates using PLD with different ablation fluences (F) and no LSR.</p><p>Using PLD ablation fluences between 5.3 - 21.7 J/cm<sup>2</sup> to deposit ta-C films all curve progressions show typical interference-maxima and -minima for partly transparent films in the measurement range (<xref ref-type="fig" rid="fig3">Figure 3</xref>). The maxima and minima appear at different wavelengths, because of differences in n and the film-thicknesses. Further experimental investigations will be shown in Section 4.3. Using PLD ablation fluences below 5.3 J/cm<sup>2</sup> maxima and minima in all curve progressions are nearly vanished (<xref ref-type="fig" rid="fig3">Figure 3</xref>).</p><p>Uncoated tungsten carbide substrates have ~44% reflectivity in the analyzed wavelength range. In comparison tungsten carbide substrates coated with ~2000 nm thick ta-C deposited by PLD using ablation fluences above 5.3 J/cm<sup>2</sup> show R values between 2% and 44% depending on the wavelength. Using ta-C coatings prepared with lower laser fluencies (&lt;5.3 J/cm<sup>2</sup> the R is reduced to 20% - 26% over the whole analyzed wavelength range. A similar behavior can be observed for steel substrates.</p><p>Investigating the optical properties of 2000 nm thick ta-C on tungsten carbide we found that an increase of the ablation fluence causes a decrease of n from about 2.8 to 2.5 and a decrease of k from about 0.7 to 0.03, respectively (see <xref ref-type="fig" rid="fig4">Figure 4</xref>(a) and <xref ref-type="fig" rid="fig4">Figure 4</xref>(b)). Similar results were obtained using steel substrates.</p><p>This behavior results from the sp<sup>3</sup>-fractionwhich corresponds to the hardness of the ta-C films. Ta-C films</p><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> R of ta-C-films deposited onto tungsten carbide substrates using different PLD ablation fluencesw</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x10.png"/></fig><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> (a) Refractive index n and (b) exctiction coefficient k (at 632 nm) in dependence of the used PLD ablation fluence F</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x11.png"/></fig><p>generated with PLD ablation fluences above 5.3 J/cm<sup>2</sup> possess a predominant sp<sup>3</sup>-bonded atomic network and thus resulting innanoindentation hardness’s between 30 GPa and 63 GPa. Whereas ta-C films deposited using PLD ablation fluences below 5.3 J/cm<sup>2</sup> show graphitic film growth with a predominant sp<sup>2</sup>-fraction. The nanoindentation hardness of these films is below 25 GPa.</p><p>The transition point between dominantly sp<sup>2</sup>-bonded or sp<sup>3</sup>-bonded amorphous film growths was determined at PLD ablation fluence about 5.3 J/cm<sup>2</sup>. At this point the measurement of n and k has large measuring errors. Hence increase of the sp<sup>3</sup>-fraction results in a preference of the optical transparence of the ta-C films i.e. the reduction of k. The higher the sp<sup>3</sup>-fraction the more the n should approximate to values of pure diamond (n nearly 2.42).</p><p>Because of the amorphous structure and the mixture of sp<sup>2</sup>- and sp<sup>3</sup>-bonding, it is not possible to reach transparencies of pure diamond (sp<sup>3</sup>-fraction 100%) for 2000 nm thick ta-C films. Ta-C films with a low sp<sup>3</sup>-fraction are characterized by an increased absorption, become opaque no thin film interference can be observed. Further investigations will be shown in the Dissertation of K. G&#252;nther [<xref ref-type="bibr" rid="scirp.56695-ref19">19</xref>] . These results are also consistent with data from several authors in the literature which have published major articles about the relation between sp<sup>3</sup>-content and the optical properties of ta-C [<xref ref-type="bibr" rid="scirp.56695-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.56695-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.56695-ref10">10</xref>] [<xref ref-type="bibr" rid="scirp.56695-ref13">13</xref>] .</p></sec><sec id="s4_3"><title>4.3. Optical Properties in Dependence on the ta-C Film Thickness</title><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows R of ta-C films with a variable film thickness deposited onto tungsten carbide using PLD ablation fluences about 12 J/cm<sup>2</sup> and optimizes LSR (internal stress below 1 GPa). Expectedly the increase of the film thickness results in a minimization of the distance between two consecutive amplitudes of the interference maxima/minima. The relation is based on formula 1 and 2 (Section 3). The higher the film thickness, the more</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> R of ta-C films with a variable film thickness deposited onto tungsten carbide using PLD ablation fluence of 12 J/cm<sup>2</sup></title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x12.png"/></fig><p>the position of the maxima will slide to higher wavelength. This effect can be used to produce wavelength selective constructive or destructive interferences in dependence on the ta-C film thickness (Section 4.5.3) [<xref ref-type="bibr" rid="scirp.56695-ref19">19</xref>] .</p><p>Further investigations show a decrease of n from 2.55 to 2.47 with increasing ta-C film thickness from nearly 2000 to around 3800 nm. However k shows low values between 0.07 and 0.1 for the inspected ta-C film thicknesses. Furthermore the amplitudes of the interference maxima and minima are reduced with increasing ta-C film thickness. The same results were obtained using steel substrates.</p><p>One possible reason for decreasing n at ta-C films with a film thickness above 3500 nm could be the rising influence of defects with increase of the film thickness. Droplets/particulates will outgrow of the ta-C film surface. This results in a higher deflection of the incident measurement irradiation. Furthermore defects can produce a deflection at their edges. The deflected irradiation fraction cannot be recorded from the detector and is therefore lost. So the calculated n could have high faults.</p></sec><sec id="s4_4"><title>4.4. The Influence LSR onto the Optical Properties of ta-C Films</title><p>Most applications for ta-C films are in the film thickness range from some 100 nm up to several micrometers. Especially in the case of using steel substrates it is important to deposit ta-C films with low internal stress to avoid the film from peeling off the substrate. Using PLD in combination with LSR, it is possible to reduce the internal stress of the ta-C films close to 0 GPa without phase transformation.</p><p><xref ref-type="fig" rid="fig6">Figure 6</xref> shows exemplary equal curve progressions for R of two nearly 1200 nm thick ta-C films onto steel substrates. One film was deposited using only the PLD and the other with the same PLD parameters but in combination with LSR. Thus one sample has maximum internal stress between 8 - 10 GPa and the other (PLD/LSR deposited) depicts internal stresses close to 0 GPa.</p><p>The refractive index of both samples is comparable (n<sub>PLD</sub> = 2.602, n<sub>PLD/LSR</sub> = 2.622) and in the range of measuring error (&#177;0.02).</p><p>On closer examination <xref ref-type="fig" rid="fig6">Figure 6</xref> show a shift between the curve progressions of these two ta-C films. This effect is the result of a minimal difference in the film thickness, explained in section 3 and 4.3. The not stress relaxed film has a thickness of about 1175 nm and the stress relaxed one has a film thickness of about 1198 nm.</p><p>The same results were obtained using tungsten carbide substrates.</p><p>Thus the application of the LSR does not influence the optical properties of ta-C films with a high sp<sup>3</sup>-fraction. Therefore the LSR process is suitable to deposit ta-C films with high optical transparency and mechanical properties like a high hardness.</p></sec><sec id="s4_5"><title>4.5. Potential of ta-C Films in the Application LOC</title><sec id="s4_5_1"><title>4.5.1. Background Fluorescence Measurements onto Different Reflectors without Using Markers</title><p>First tests regarding fluorescence signals of flat uncoated and coated reflectors were taken out using the set-up shown in <xref ref-type="fig" rid="fig2">Figure 2</xref> using an uncoated glass slide, without any dyes. Therefore the highest possible sensitivity of</p><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Comparison between curve progressions of R of nearly 1200 nm thick ta-C films deposited using a combination of PLD/LSR</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x13.png"/></fig><p>the photomultiplier and conditions as shown in <xref ref-type="table" rid="table1">Table 1</xref> were utilized. The mean value of the fluorescence signal was estimated from 100.000 measured values.</p><p>In all cases the analyzed reflectors show minimal fluorescence values at the different excitation wavelengths, which are equal to those of gold. The fluorescence signal for ta-C films shows values between 0.09 and 0.10 V (excitation wavelength 479 &#177; 20 nm, detection wavelength 524 &#177; 20 nm), independent of the used LSR process or used ablation fluence onto the target during the film deposition.</p><p>This means, that the ta-C coating insulates the fluorescence of basic material from the detection. Hence the influence of the excitation wavelength onto the measurement signal can be eliminated using ta-C films.</p></sec><sec id="s4_5_2"><title>4.5.2. Fluorescence Measurements Using Markers and Different Reflectors</title><p>In a further step fluorescence measurements of a fluorescence marker were taken out by replacing the uncoated glass slide with a fluorescence-marker-coated glass slide (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p><p>The signal of the fluorescence irradiation emitted by the marker was measured at a fixed position without and with a reflector in a distance of about 500 &#181;m. For a better visualization the amplification of the measured fluorescence signal is described subsequent using an amplification-factor (A):</p><p>A = sensor signal with reflector/sensor signal without reflector (4)</p><p>Using a reflector increases the sensor signal (using maximal sensitivity) compared to measurements which were taken out without any reflector for all analyzed reflectors and excitation/detection wavelengths. <xref ref-type="fig" rid="fig7">Figure 7</xref> shows exemplary at an excitation wavelength of about 479 &#177; 20 nm and detection wavelength 524 &#177; 20 nm for the analyzed reflectors. In consequence it is on the one hand possible to increase the signal to noise ratio. On the other hand the coating gives the opportunity to suppress the excitations of underlying layers.</p><p>In comparison to the gold or the uncoated tungsten carbide reflector A of the nearly 2000 nm thick ta-C films is lower. This effect results from R of the used reflectors (<xref ref-type="fig" rid="fig8">Figure 8</xref>).</p><p>Gold has R of about 80%, tungsten carbide of 44% and 2000 nm ta-C films on tungsten carbide of nearly 20% at the detection wavelength of about 524 &#177; 20 nm. Due to that fact it is possible to optimize R of the reflectors for defined wavelength. Using ta-C films with a high sp<sup>3</sup>-fraction the effect of generating interference maxima and minima at well-defined wavelength can be used for wavelength selective amplification of the measured fluorescence signal.</p></sec><sec id="s4_5_3"><title>4.5.3. Example for an Optimized Combination out of ta-C Film Thickness and Marker</title><p>Based on Rat the analyzed wavelength range useful combinations of film-marker were determined. <xref ref-type="fig" rid="fig9">Figure 9</xref> shows exemplary a combination of a1000 nm thick ta-C film on steel and the fluorescence marker Cy7 (BD Biosciences) or QDOT800 (Nanocrystal). The excitation wavelength for these markers is in the range of an interference minimum in the curve progression of R of the 1000 nm thick ta-C film, whereas the detection wavelength of these markers is at an interference maximum (<xref ref-type="fig" rid="fig9">Figure 9</xref>).</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Test conditions during the fluorescence measurements</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Parameter</th><th align="center" valign="middle" >Value</th></tr></thead><tr><td align="center" valign="middle" >Channel height</td><td align="center" valign="middle" >500 &#181;m</td></tr><tr><td align="center" valign="middle" >Excitation wavelength</td><td align="center" valign="middle" >467 nm &#177; 20 nm</td></tr><tr><td align="center" valign="middle" >Detection or fluorescence wavelength</td><td align="center" valign="middle" >530 nm &#177; 20 nm</td></tr><tr><td align="center" valign="middle" >Marker</td><td align="center" valign="middle" >Mixture consisting of different laser dyes embedded into a homogeneous polymer film at the glass slide</td></tr><tr><td align="center" valign="middle" >Sensitivity adjustment of the photomultiplier</td><td align="center" valign="middle" >20 percent for marker detection; 100 percent for background signal detection</td></tr><tr><td align="center" valign="middle" >Range of the photomultiplier</td><td align="center" valign="middle" >0 - 5 arbitrary unit (a.u.)</td></tr><tr><td align="center" valign="middle" >LED power adjustment</td><td align="center" valign="middle" >30 percent</td></tr></tbody></table></table-wrap><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Amplification-factor (A) of ~2000 nm thick ta-C films deposited onto tungsten carbide using different deposition parameters in comparison with gold- and tungsten carbide reflector. The excitation wavelength was 479 (&#177;20) nm and the detection wavelength 524 (&#177;20) nm</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x14.png"/></fig><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig8">Figure 8</xref></label><caption><title> R curve progression of different reflectors in the wavelength range 380 nm - 1050 nm</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x15.png"/></fig></sec></sec></sec><sec id="s5"><title>5. Conclusions</title><p>In this study the optical properties of ta-C films deposited by PLD have been analyzed. It is shown, that R of several &#181;m thick ta-C films does not depend on the used tungsten carbide or steel substrate, if Ra of the substrates possesses values below 10 nm.</p><p>Further investigations show the reduction of n (2.8 - 2.5) and simultaneously of k (0.7 - 0.03) caused by the</p><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig9">Figure 9</xref></label><caption><title> Exemplary R for a nearly 1000 nm thick ta-C film deposited by PLD onto tungsten carbide substrate and marked wavelength ranges for excitation (grey) and fluorescence-emission (dark grey) for the fluorescence marker Cy7</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/10-7701579x16.png"/></fig><p>increase of the used ablation fluence during the PLD process. Consequently a rising sp<sup>3</sup>-fraction of the ta-C films with increasing the ablation fluence can be reasoned.</p><p>Ta-C films with a high sp<sup>3</sup>-fraction generate interference maxima and minima, if the ablation fluence during deposition is higher than 5.3 J/cm<sup>2</sup>. The possibility to form interference maxima/minima gives the opportunity for an application as high refractive films for reflectivity minimization or reflectivity increase in the visible and near infrared wavelength range. Furthermore it is conceivable to use ta-C films with a high sp<sup>3</sup>-contant for decorative and at once wear resistant applications like jewelry or infrared optics.</p><p>Ta-C films with high sp<sup>2</sup>-content, in our case deposited by fluences below 5.3 J/cm<sup>2</sup>, could be used as anti- reflection coatings in the wavelength range 380 - 1050 nm. The transition point between graphitic and diamond film growth was determined at an ablation fluence of about 5.3 J/cm<sup>2</sup>.</p><p>The mechanical and optical parameters, like n and k of ta-C films can be modified using different ablation fluences. Further investigations exhibit no influence of the used LSR process onto the optical properties of ta-C films.</p><p>The implementation of ta-C film based reflectors in a LOC system shows that it is possible to minimize background fluorescence from flow cell and cover. Furthermore it is possible to increase wavelength-selective the emitted fluorescence signal and decrease the excitation wavelength signal using ta-C coated channel walls. One great advantage in using ta-C films with high sp<sup>3</sup>-content in LOC is the minimization of the costs in comparison to using gold layers. To increase the measured signal of the fluorescence in LOC systems, further investigations concerning multilayers are promising.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This work has been technical and material supported by the University of Applied Sciences Mittweida and the Fraunhofer Institute for Material and Beam Technology IWS Dresden. The author gratefully acknowledges Steffen Wei&#223;mantel and Rene Eger.</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.56695-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">(2012) Kohlenstoffschichten-Grundlagen, Schichttypen und Eigenschaften: VDI2840-2012-06, in VDI-Handbuch Pro- duktionstechnik und Fertigungsverfahren, Band 3, Betriebsmittel VDI-Handbuch Werkstofftechnik Verein Deutscher Ingenieure Beuth, Verlag GmbH, Berlin.</mixed-citation></ref><ref id="scirp.56695-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Charitidis, C.A. (2010) Nanomechanical and Nanotribological Properties of Carbon-Based Thin Films: A Review. International Journal of Refractory Metals and Hard Materials, 28, 51-70.  http://dx.doi.org/10.1016/j.ijrmhm.2009.08.003</mixed-citation></ref><ref id="scirp.56695-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Kang, M.C., Tak, H.S., Jeong, Y.K., Lee, H.W. and Kim, J.S. (2010) Properties and Tool Performance of ta-C Films Deposited by Double-Bend Filtered Cathodic Vacuum Arc for Micro Drilling Applications. Diamond and Related Materials, 19, 866-869. http://dx.doi.org/10.1016/j.diamond.2010.02.002</mixed-citation></ref><ref id="scirp.56695-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Schulz, H., Scheibe, H.-J., Siemroth, P. and Schultrich, B. (2004) Pulsed Arc Deposition of Super-Hard Amorphous Carbon Films. Applied Physics, A78, 675-679. http://dx.doi.org/10.1007/s00339-003-2280-8</mixed-citation></ref><ref id="scirp.56695-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Neuville, S. and Matthews, A. (2007) A Perspective on the Optimization of Hard Carbon and Related Coatings for Engineering Applications. Thin Solid Films, 515, 6619-6653. http://dx.doi.org/10.1016/j.tsf.2007.02.011</mixed-citation></ref><ref id="scirp.56695-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Yu, H., Li, P. and Robertson, J. (2011) Fabrication and Bio-Functionalization of Tetrahedral Amorphous Carbon Thin Films for Bio Sensor Applications. Diamond and Related Materials, 20, 1020-1025. http://dx.doi.org/10.1016/j.diamond.2011.06.005</mixed-citation></ref><ref id="scirp.56695-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Patsalas, P. (2011) Optical Properties of Amorphous Carbons and Their Applications and Perspectives in Photonics. Thin Solid Films, 519, 3990-3996. http://dx.doi.org/10.1016/j.tsf.2011.01.202</mixed-citation></ref><ref id="scirp.56695-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Mathioudakis, C., Kopidakis, G., Patsalas, P. and Kelires, P.C. (2007) Disorder and Optical Properties of Amorphous Carbon. Diamond and Related Materials, 16, 1788-1792. http://dx.doi.org/10.1016/j.diamond.2007.08.009</mixed-citation></ref><ref id="scirp.56695-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Schultrich, B. (2011) Modeling of ta-C Growth: Influence of the Technological Parameters. Diamond and Related Materials, 20, 785-792. http://dx.doi.org/10.1016/j.diamond.2011.03.035</mixed-citation></ref><ref id="scirp.56695-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Tay, B.K., Shi, X., Cheah, L.K. and Flynn, D.I. (1997) Optical Properties of Tetrahedral Amorphous Carbon Films Determined by Spectroscopic Ellipsometry. Thin Solid Films, 308-309, 268-272.  http://dx.doi.org/10.1016/S0040-6090(97)00425-2</mixed-citation></ref><ref id="scirp.56695-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Panwar, O.S., Khan, M.A., Bhattacharjee, B., Pal, A.K., Satyanarayana, B.S., Dixit, P.N., Bhattacharyya, R. and Khan, M.Y. (2006) Reflectance and Photoluminescence Spectra of as Grown and Hydrogen and Nitrogen Incorporated Tetrahedral Amorphous Carbon Films Deposited Using an S Bend Filtered Cathodic Vacuum Arc Process. Thin Solid Films, 515, 1597-1606. http://dx.doi.org/10.1016/j.tsf.2006.05.024</mixed-citation></ref><ref id="scirp.56695-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Panwar, O.S., Khan, M.A., Kumar, M., Shivaprasad, S.M., Satyanarayana, B.S., Dixit, P.N., Bhattacharyya, R. and Khan, M.Y. (2008) Effect of High Substrate Bias and Hydrogen and Nitrogen Incorporation on Filtered Cathodic Vacuum Arc Deposited Tetrahedral Amorphous Carbon Films. Thin Solid Films, 516, 2331-2340.  http://dx.doi.org/10.1016/j.tsf.2007.09.024</mixed-citation></ref><ref id="scirp.56695-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Panwar, O.S., Khan, M.A., Kumar, S., Basu, A., Mehta, B.R. and Kumar, S. (2010) Effect of High Substrate Bias and Hydrogen and Nitrogen Incorporation of Spectroscopic Ellipsometric and Atomic Force Microscopic Studies of Tetrahedral Amorphous Carbon Films. Surface and Coatings Technology, 205, 2126-2133.  http://dx.doi.org/10.1016/j.surfcoat.2010.08.119</mixed-citation></ref><ref id="scirp.56695-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">WeiBmantel, S., ReiBe, G. and Rost, D. (2004) Preparation of Super-Hard Amorphous Carbon Films with Low Internal Stress. Surface and Coatings Technology, 188-189, 268-273. http://dx.doi.org/10.1016/j.surfcoat.2004.08.070</mixed-citation></ref><ref id="scirp.56695-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Materne, E.-M., Maschmeyer, I.J., Lorenz, A.K., Horland, R., Schimek, K.M.S., Busek, M., Sonntag, F., Lauster, R. and Marx, U. (2015) The Multi-Organ Chip—A Microfluidic Platform for Long-Term Multi-Tissue Coculture. Journal of Visualized Experiments, 98, e52526. http://dx.doi.org/10.3791/52526</mixed-citation></ref><ref id="scirp.56695-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Maschmeyer, I., Lorenz, A.K., Schimek, K., Hasenberg, T., Ramme, A.P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., Sambo, N.S., Sonntag, F., Lauster, R. and Marx, U. (2015) A Four-Organ-Chip for Interconnected Long-Term Co-Culture of Human Intestine, Liver, Skin and Kidney Equivalents. In: Lab on a Chip.</mixed-citation></ref><ref id="scirp.56695-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Schmieder, F., Schmieder, S., Eger, R., Friedrich, S., Werner, A., Danz, N., Marx, U. and Sonntag, F. (2012) Automated Universal Chip Platform for Fluorescence Based Cellular Assays. Biomedical Engineering/Biomedizinische Technik, 57, 340-343. http://dx.doi.org/10.1515/bmt-2012-4319</mixed-citation></ref><ref id="scirp.56695-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Pedrotti, F., Pedrotti, L., Bausch, W. and Schmidt, H. (2008) Optik für Ingenieure. Springer, Berlin.</mixed-citation></ref><ref id="scirp.56695-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Günther, K. (2014) Erzeugung und Anwendungspotential von mit dem PLD-Verfahren Hergestellten Superharten Amorphen Kohlenstoffschichten. PhD Dissertation, Shaker-Verlag, Maastricht.</mixed-citation></ref></ref-list></back></article>