<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JBM</journal-id><journal-title-group><journal-title>Journal of Biosciences and Medicines</journal-title></journal-title-group><issn pub-type="epub">2327-5081</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jbm.2015.34002</article-id><article-id pub-id-type="publisher-id">JBM-55434</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject></subj-group></article-categories><title-group><article-title>
 
 
  Ionization Chamber Dosimetry for Conventional and Laser-Driven Clinical Hadron Beams
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>F.</surname><given-names>Scarlat</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>A.</surname><given-names>Scarisoreanu</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>E.</surname><given-names>Badita</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>C.</surname><given-names>Vancea</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>I.</surname><given-names>I. Calina</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Fl.</surname><given-names>Scarlat</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>N.</surname><given-names>Verga</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib></contrib-group><aff id="aff4"><addr-line>University of Medicine and Pharmacy “Carol Davila”, Bucharest, Romania</addr-line></aff><aff id="aff1"><addr-line>Valahia Univesity of Targoviste, Targoviste, Romania</addr-line></aff><aff id="aff3"><addr-line>BitSolutions, Bucharest, Romania</addr-line></aff><aff id="aff2"><addr-line>National Institute for Laser, Plasma and Radiation Physics-INFLPR, Bucharest-Magurele, Romania</addr-line></aff><pub-date pub-type="epub"><day>09</day><month>04</month><year>2015</year></pub-date><volume>03</volume><issue>04</issue><fpage>8</fpage><lpage>17</lpage><history><date date-type="received"><day>January</day>	<month>2015</month>	</date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   The practice of using the direct ionization radiation (electrons, protons, antiprotons, pions, ions, etc) or of the indirect ionization radiation (photons, neutrons, etc) in economy and social life has led to the introduction of the absorbed dose magnitude (ICRU 1953) defined as the energy absorbed per mass unit of the irradiated substance. This is a fundamental magnitude valid for any type of ionizing radiation, any irradiated material and any radiation energy. In case of clinical hadron beams generated by conventional accelerators or those controlled by lasers, IAEA TRS 398 recommends the absorbed dose to water. This may be determined employing the calorimeter method with water or graphite, chemical method, fluence based measurements as Faraday cups or activation measurements, and the ionization chamber method. In this paper the selected method was the thimble air filled ionization chamber method for determination of absorbed dose to water. 
 
</p></abstract><kwd-group><kwd>Absorbed Dose to Water</kwd><kwd> Ionization Chamber</kwd><kwd> Hadron Therapy</kwd><kwd> Hadron Dosimetry</kwd><kwd> Expand  Uncertainty</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The ionization method for determining the absorbed dose in air and next in any irradiated substance by means of Bragg-Gray theory, was used by the Institute of Atomic Physics (IFA) in Bucharest located on Magurele Platform, (established in 1956) with the first 30 MeV Betatron Accelerator built and commissioned in 1960 [<xref ref-type="bibr" rid="scirp.55434-ref1">1</xref>].</p><p>Methods, techniques and technologies with bremsstrahlung and electron beams developed at the 30 MeV Betatron that have applications in economy and social life, employed the dosimetry with Siemens ionization cham- bers [<xref ref-type="bibr" rid="scirp.55434-ref2">2</xref>]. Such applications were: non-destructive defectoscopy, photonuclear reactions, elemental analysis, therapy with bremsstrahlung radiation of 30 MeV and therapy with electron beams of 25 MeV [<xref ref-type="bibr" rid="scirp.55434-ref3">3</xref>]. The next step was the use of the method with PTW dosimetric apparatus at the 40 MeV Medical Betatron [<xref ref-type="bibr" rid="scirp.55434-ref4">4</xref>].</p><p>Moreover, the method was applied in the dosimetric measurements run at other types of electron accelerators built at IFA, IFTAR (established in 1977 but rooted in IFA) and INFLPR ( re-named IFTAR in 1996), such as: the 3 MeV linear accelerator [<xref ref-type="bibr" rid="scirp.55434-ref5">5</xref>], the 8 MeV technologic betatron [<xref ref-type="bibr" rid="scirp.55434-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref7">7</xref>], the 15 MeV industrial betatron [<xref ref-type="bibr" rid="scirp.55434-ref8">8</xref>], the 11.5 MeV microtron [<xref ref-type="bibr" rid="scirp.55434-ref9">9</xref>], the 10 MeV linear accelerator [<xref ref-type="bibr" rid="scirp.55434-ref10">10</xref>] and the 7 MeV defectoscopic linear accelerator [<xref ref-type="bibr" rid="scirp.55434-ref11">11</xref>].</p><p>Today, in its infrastructure, INFLPR includes a Secondary Standard Dosimetry Laboratory at High Energies- STARDOOR [<xref ref-type="bibr" rid="scirp.55434-ref12">12</xref>], accredited by Romanian Accreditation Association (RENAR) to perform testing and calibra- tion in beams of photons, electrons and high-energy neutrons in accordance with SR EN ISO/IEC 17025:2005. The dosimetric measurements performed by the laboratory are traceable to the reference standard developed and maintained by PTB.</p><p>It is also worth mentioning that an APOLLON laser system of 10 PW (150 J, 15 fs) [<xref ref-type="bibr" rid="scirp.55434-ref13">13</xref>], now under con- struction on Magurele Platform near Bucharest, induced the idea of using it to generate the therapeutic hadrons beams (protons and carbon ions) with energies of 50 to 250 MeV and 100 to 450 MeV/u, respectively. In this way it is possible to skip the stage of conventional accelerators (isochronous cyclotron, synchrocyclotron, synchrotron and linac types) which also include compact accelerators in the design phase (FFAG, DWA and cyclinac) and directly pass to the alternative of using the laser-driven carbon ion/proton therapy beams [<xref ref-type="bibr" rid="scirp.55434-ref14">14</xref>].</p><p>In this respect, it is mandatory to extend the functions of STARDOOR Lab for performing clinical testing and calibration in beams of protons and carbon ions. In view of that the material base is ensured by outfitting the platform with a 10 PW laser and the STARDOOR Lab with cylindrical and plane parallel ionization chambers calibrated at PTB.</p><p>Taking into account the above and the experience gained in international hadron-based therapy centers with protons and carbon ions, the reference dosimetry techniques for clinical beams of hadrons-calorimetric dosimetry, chemical dosimetry, ionization dosimetry with Faraday cup and ionization chamber dosimetry-this paper presents how to measure the absorbed dose to water in clinical hadron beams employing the ionization chamber dosimetry.</p></sec><sec id="s2"><title>2. Ionization Method and Materials</title><sec id="s2_1"><title>2.1. Some Requirements for Clinical Hadron Beam</title><p>Clinical proton and ion beams are characterized by two very important parameters. The first parameter is the hadron kinetic energy which provides the practical range, the Bragg Peak or Spred Out Bragg-Peak (SOBP) of it, at any depth of a patient tumour ranging between 2.19 cm (50 MeV) and 376 cm (250 MeV) for protons and between 2.59 cm (1200 MeV) and 33.00 cm (5400 MeV) for carbon ions (<xref ref-type="fig" rid="fig1">Figure 1</xref>) [<xref ref-type="bibr" rid="scirp.55434-ref14">14</xref>].</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Definitions of practical range, R<sub>p</sub> and residual range, R<sub>res, </sub>and Spred Out Bragg-Peak (SOBP)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/55434x3.png"/></fig><p>The second important parameter of the hadron beam is represented by the beam particle intensity which provides the administration of the required absorbed dose at the level of the tumour located at any depth in the patient. The hadron beam intensity value is about (1 - 5) &#215; 10<sup>10</sup> proton/s [<xref ref-type="bibr" rid="scirp.55434-ref15">15</xref>].</p><p>A simple scheme for the calculation of the absorbed dose starting either from the tumour (the absorbed dose ε<sub>T</sub>, tumour mass m<sub>T</sub> and dose in tumour D<sub>T</sub>) to the laser system, or from the laser system (pulse energy ε<sub>L</sub>, pulse peak P<sub>0</sub> and τ<sub>0</sub> = τ<sub>FWHM</sub>―the pulse duration) to the tumour, is presented in <xref ref-type="fig" rid="fig2">Figure 2</xref> [<xref ref-type="bibr" rid="scirp.55434-ref16">16</xref>].</p><p>The operation condition imposed on the scheme in order to provide the absorbed dose D<sub>T</sub> in the tumor is</p><disp-formula id="scirp.55434-formula1"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x4.png"  xlink:type="simple"/></disp-formula><p>This condition requires that the product between the conversion efficiency η of the laser pulse energy into hadrons kinetic energy and laser pulse energy ε<sub>L</sub> should be greater or equal to the absorbed dose in the tumor ε<sub>T</sub> divided by the product between the laser pulse repetition frequency f<sub>R</sub> and the irradiation time t<sub>T</sub> established by the doctor overseeing therapy.</p></sec><sec id="s2_2"><title>2.2. Ionization Method Principle</title><p>The ionization method is used to determine the dosimetric quantities which characterize the direct and indirect ionization radiation.</p><p>The basic principle of the ionization method with open ionization chambers (not sealed) and closed (sealed) is known [<xref ref-type="bibr" rid="scirp.55434-ref17">17</xref>]. By irradiating the gas in the sensitive volume V of the ionization chamber with energy fluence Ψ [MeV/cm<sup>2</sup>] of the radiation beam, one may collect a charge (one sign) q [C] measured in volume V filled with ambient air of mass m<sub>air</sub> and density ρ<sub>air</sub> = 1293 &#215; 10<sup>−</sup><sup>3</sup> g/cm<sup>3</sup> at STP. Types of cylindrical or plan parallel ioniza- tion chambers may be used for absolute dosimetry.</p><p>The associated method device is very simple and has three main components: the ionization chamber, an electrometer and a power supply. The ionization chamber, filled with gas (usually ambient air) is a radiation detector in which ions generated by the interaction of a radiation beam (direct or indirect ionizing radiation), are collected due to the existence of an electric field created between two electrodes, between which a potential difference is established. The electrometer is a device that measures very small values of the electrical currents and charge provided by the ionization chambers. The measuring device is electric-power supplied.</p><p>Main dosimetric quantities measured or determined by the ionization method with the associated device, ex- cept the correction factors, are: exposure X only for photon only in air, air kerma K<sub>air</sub> (≡K<sub>a</sub>) the average amount of energy transferred in a small volume from the indirect ionizing radiation to direct ionizing radiation, the absorbed dose in air D<sub>air</sub> (≡D<sub>a</sub>) and the absorbed dose to water D<sub>w</sub>, defined as a mean energy imparted by ionizing radiation to a matter in a finite volume V. The unit of absorbed dose is the gray (1 Gy = 1 J∙kg<sup>−1</sup>).</p><p>These quantities are proportional to the measured electrical charge per mass unit</p><disp-formula id="scirp.55434-formula2"><label>(2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x5.png"  xlink:type="simple"/></disp-formula><p>where ε is the deposited energy expressed in joule per number of created charge in coulombs (ε ≡ (W<sub>air</sub>/e)), s<sub>w,air</sub> is the stopping power ratio (STPR) of the particle beam for water and air (η ≡ s<sub>w,air</sub> = (S/ρ)<sub>w</sub>/(S/ρ)<sub>air</sub>) and g is the average fraction of energy which transferred to electrons and then lost through radiation processes. The stopping power intervenes in the relation to determine the absorbed dose in any substance different from air as a result of Bragg-Gray theory [<xref ref-type="bibr" rid="scirp.55434-ref17">17</xref>].</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Scheme for the absorbed dose calculation</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/55434x6.png"/></fig><p>The current best estimate for the average value of W<sub>air</sub> in <sup>60</sup>C is 33.97 eV/i.p. or 33.97∙1.602∙10<sup>−19</sup> (J/i・p). Taking into account that electrical charge of the ion pair (i∙p.) is of 1.602・10<sup>−19</sup> (C/i・p.) it results that for dry air, (W<sub>air</sub>/e)<sub>e</sub><sub>,γ</sub> = 33.97 J/C. This value is valid for high energy electron and photon beams [IAEA TRS 398] [<xref ref-type="bibr" rid="scirp.55434-ref18">18</xref>].</p><p>Dosimetric quantities (X, K<sub>air</sub>, D<sub>air</sub>, D<sub>w</sub>) determined in the calibration beam of quality Q<sub>o</sub> (≡<sup>60</sup>Co γ rays beam) by a reference dosimeter lab have the following calibration factors for the user chambers:</p><disp-formula id="scirp.55434-formula3"><label>(3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x7.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.55434-formula4"><label>(4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x8.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.55434-formula5"><label>(5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x9.png"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.55434-formula6"><label>(6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x10.png"  xlink:type="simple"/></disp-formula><p>In case that one of those dosimetric quantities along with the corresponding calibration factor is determined in the beam of quality Q<sub>o</sub>, there is the possibility to determine the other three calibration factors using the method of calibration factor conversion given by the relation (2).</p><p>For example: knowing the exposure X<sub>Qo</sub> in the calibration beam Qo, and the corresponding calibration factor N<sub>X</sub><sub>,Qo</sub> = X<sub>Qo</sub>/M<sub>Qo</sub> [C/kg], determined by a reference lab for the user ionization chamber, it is possible to determine the calibration factor with the relation (2) of air kerma in air N<sub>K</sub><sub>,Qo</sub>[Gy] = (W/e)<sub>air</sub>N<sub>X</sub><sub>,Qo</sub>/(1-g), and next N<sub>D,air,Qo</sub>, N<sub>w,Qo</sub> and finally, the absorbed dose to water from a beam of another quality Q, IAEA TRS 277 [<xref ref-type="bibr" rid="scirp.55434-ref19">19</xref>].</p><p>The ICRU 59 [<xref ref-type="bibr" rid="scirp.55434-ref20">20</xref>] protocol allows for determinations based on exposure, air kerma, absorbed dose to air and absorbed dose to water calibrations in a <sup>60</sup>Co gamma beam [<xref ref-type="bibr" rid="scirp.55434-ref21">21</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref22">22</xref>]. AIEA TRS 398 recommends the determination of the calibration factor for the absorbed dose starting from the absorbed dose to water in the calibration beam Qo.</p><p>Yet, in order to compare the medical results of the today and future hadron-based therapy with the results obtained by now with the hadron-based therapy and the conventional therapy and even for verifying the results of the dosimetric measurements, it is necessary that the conversion relations between the calibration factors to exposure: N<sub>X</sub><sub>,Qo</sub>, N<sub>K</sub><sub>,Qo</sub>, N<sub>D,</sub><sub>air,Qo</sub> and N<sub>w</sub><sub>,Qo</sub>,<sub> </sub>be defined and measured in the beam of<sub> </sub>quality Q<sub>o</sub> in order to determine the corresponding 4 dosimetric quantities [<xref ref-type="bibr" rid="scirp.55434-ref15">15</xref>].</p><p>At present there are two protocols of dosimetry which state the formalism and the data referring to the calibration of a ionization chamber in a standard lab for the measurement of the absorbed dose to water under reference conditions in the clinical beam [<xref ref-type="bibr" rid="scirp.55434-ref18">18</xref>].</p><p>The first protocol is based on air kerma in air calibration coefficients (formalism N<sub>K</sub>-N<sub>D</sub><sub>,w</sub>),</p><disp-formula id="scirp.55434-formula7"><label>(7)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x11.png"  xlink:type="simple"/></disp-formula><p>where the correction factors (k<sub>att</sub>. k<sub>m</sub>. k<sub>cel</sub>) are defined in [<xref ref-type="bibr" rid="scirp.55434-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref19">19</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref23">23</xref>] and the absorbed dose to water based on air kerma is</p><disp-formula id="scirp.55434-formula8"><label>(8)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x12.png"  xlink:type="simple"/></disp-formula><p>With the correction factors <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/55434x13.png" xlink:type="simple"/></inline-formula> defined in [<xref ref-type="bibr" rid="scirp.55434-ref18">18</xref>].</p><p>The second protocol is based on the absorbed dose to water calibration coefficients (formalismul N<sub>D</sub><sub>,w</sub>). In this case the absorbed dose to water is</p><disp-formula id="scirp.55434-formula9"><label>(9)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x14.png"  xlink:type="simple"/></disp-formula><p>From the equality of the relations (8) and (9), it results a second calculation expression for the calibration factor of the absorbed dose to air function of the calibration factor of the absorbed dose to water N<sub>D</sub><sub>,w,Qo</sub></p><disp-formula id="scirp.55434-formula10"><label>(10)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x15.png"  xlink:type="simple"/></disp-formula><p>The first expression being given by relation (7) function of the calibration factor air kerma in air N<sub>K</sub><sub>,Qo</sub>.</p></sec></sec><sec id="s3"><title>3. Determination of the Absorbed Dose in Proton and Carbon Ion Beams</title><sec id="s3_1"><title>3.1. Reference Conditions for Dose Determination</title><p>The reference conditions for the determination of the absorbed dose in proton and ion beams recommended by AIEA TRS 398 are presented in <xref ref-type="table" rid="table1">Table 1</xref>.</p></sec><sec id="s3_2"><title>3.2. Absorbed Dose for Hadrons in Other Quality</title><p>The absorbed dose to water in the proton or carbon ion beam of quality Q is given by relation</p><disp-formula id="scirp.55434-formula11"><label>, (11)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x16.png"  xlink:type="simple"/></disp-formula><p>where M<sub>Q</sub> is ionization chamber reading in [C] corrected for influence quantities at Q, N<sub>D</sub><sub>,w,Qo</sub> the absorbed dose to water calibration factor of ionization chamber in a beam of quality Q<sub>o</sub>, and k<sub>Q,Qo</sub> is the beam quality correction factor of quality Q. Note that relation (11) based on formalism N<sub>D</sub><sub>,w</sub>-IAEA TRS 398 determines the absorbed dose to water D<sub>w</sub><sub>,Q</sub> (z<sub>ref</sub>) at any user quality Q (protons, carbon ions, electrons, photons, antiprotons, π-mesons etc.).</p><p>The distribution of the dose absorbed in depth for clinical protons with energy ranging between 50 MeV and 250 MeV is presented in <xref ref-type="fig" rid="fig3">Figure 3</xref> [<xref ref-type="bibr" rid="scirp.55434-ref24">24</xref>].</p><p>The quality factor k<sub>Q,Qo</sub> can be measured in both qualities Q and Q<sub>0</sub> of the beam in a standard laboratory, but, due to the experimental limits, most of the times it is calculated. The values for k<sub>Q,Qo</sub> were calculated by Formula (12) and are presented in TRS 398, in function of the hadron beam<sub> </sub>quality parameter R<sub>res</sub>. <xref ref-type="table" rid="table2">Table 2</xref> is a synthesis of the parameters of the component formula k<sub>QQo</sub> factor.</p><p>The calculation formulae for the factor of quality k<sub>Q</sub><sub>,Qo</sub> is given by the relation</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Reference conditions for the determination of absorbed dose in proton and ion beams [IAEA TRS 398]</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Influence quantity</th><th align="center" valign="middle"  colspan="2"  >Reference values or reference characteristics</th></tr></thead><tr><td align="center" valign="middle" >Particle type</td><td align="center" valign="middle" >Protons</td><td align="center" valign="middle" >Carbon ions</td></tr><tr><td align="center" valign="middle" >Quality beam</td><td align="center" valign="middle" >Residual range</td><td align="center" valign="middle" >Residual range</td></tr><tr><td align="center" valign="middle" >Phantom</td><td align="center" valign="middle" >water</td><td align="center" valign="middle" >water</td></tr><tr><td align="center" valign="middle" >SSD</td><td align="center" valign="middle" >clinical treatment distance</td><td align="center" valign="middle" >clinical treatment distance</td></tr><tr><td align="center" valign="middle" >Field size</td><td align="center" valign="middle" >10 cm &#215; 10 cm</td><td align="center" valign="middle" >10 cm &#215; 10 cm</td></tr><tr><td align="center" valign="middle" >Reference dosimeter</td><td align="center" valign="middle" >IC thimble or PPC</td><td align="center" valign="middle" >IC thimble or PP</td></tr><tr><td align="center" valign="middle" >Ionization Chamber (IC) or Plan Paralel Chamber (PPC) type</td><td align="center" valign="middle" >for R<sub>res</sub> ≥ 0.5 g∙cm<sup>2</sup>, IC thimble or PPC for R<sub>res</sub> &lt; 0.5 g∙cm<sup>2</sup>, PPC</td><td align="center" valign="middle" >for SOBP width ≥ 2 g∙cm<sup>2</sup>, IC or PP for SOBP width &lt; 2 g∙cm<sup>2</sup>, PP</td></tr><tr><td align="center" valign="middle" >Measurement depth, z<sub>ref</sub></td><td align="center" valign="middle" >middle of the SOBP/plateau</td><td align="center" valign="middle" >middle of the SOBP/plateau</td></tr><tr><td align="center" valign="middle" >Calibration quality, Qo</td><td align="center" valign="middle" >Co-60 beam</td><td align="center" valign="middle" >Co-60 beam</td></tr><tr><td align="center" valign="middle" >IC calibration factor</td><td align="center" valign="middle" >N<sub>D,w</sub>-TRS 398 N<sub>X</sub>, N<sub>K</sub>, N<sub>D,w</sub>-ICRU59</td><td align="center" valign="middle" >N<sub>D,w</sub>-TRS398</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Specific factors for Q hadron beams and for the Q<sub>o</sub> calibration beam</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >k<sub>Q,Qo</sub> parameter</th><th align="center" valign="middle" >Value for protons</th><th align="center" valign="middle" >Values for carbon ions</th></tr></thead><tr><td align="center" valign="middle" >(s<sub>w,air</sub>) Qo</td><td align="center" valign="middle" >1.133</td><td align="center" valign="middle" >1.133</td></tr><tr><td align="center" valign="middle" >(s<sub>w,air</sub>) Q</td><td align="center" valign="middle" >Function of E</td><td align="center" valign="middle" >Function of E</td></tr><tr><td align="center" valign="middle" >(W<sub>air</sub>/e) Qo<sub> </sub></td><td align="center" valign="middle" >33.97 eV</td><td align="center" valign="middle" >33.97 eV</td></tr><tr><td align="center" valign="middle" >(W<sub>air</sub>/e) Q</td><td align="center" valign="middle" >34.50 eV</td><td align="center" valign="middle" >34.23 eV</td></tr><tr><td align="center" valign="middle" >p<sub>Qo</sub></td><td align="center" valign="middle" >1.009</td><td align="center" valign="middle" >1.009</td></tr><tr><td align="center" valign="middle" >p<sub>Q</sub></td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1.0</td></tr></tbody></table></table-wrap><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Relative dose vs. proton depth in water [<xref ref-type="bibr" rid="scirp.55434-ref24">24</xref>]</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/55434x17.png"/></fig><disp-formula id="scirp.55434-formula12"><label>, (12)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x18.png"  xlink:type="simple"/></disp-formula><p>where s<sub>w,</sub><sub>air</sub> is the water to air mass collision stopping power ratio, (W<sub>air</sub>/e)<sub>p</sub> is the mean energy required to produce an ion pair in dry air and p<sub>Q</sub> is a correction factor accounting the perturbation by the presence of the ion chamber in the phantom [<xref ref-type="bibr" rid="scirp.55434-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref19">19</xref>].</p><p>Equations (11) and (12) may be expressed in the form of the product of three factors [<xref ref-type="bibr" rid="scirp.55434-ref25">25</xref>]:</p><disp-formula id="scirp.55434-formula13"><label>(13)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x19.png"  xlink:type="simple"/></disp-formula><p>The first factor represents the corrected reading of the chamber, the second factor represents the factors specific to the calibration beam and the third factor represents the factors specific to the hadron beam.</p><p>The ε = (W<sub>air</sub>/e) factor. Based on the analysis of all the experimental measurements conducted by now, for protons TRS 398 recommends the value of ε factor of (W<sub>air</sub>/e)<sub>p</sub> = 34.50 J/C and for the carbon ions, the value of (W<sub>air</sub>/e)<sub>i.c.</sub> = 34.23 J/C , for all energies of the protons and carbon ions beams used in therapy.</p><p>The stopping power measured in [MeVcm<sup>2</sup>/g]. TRS 398 recommends that values for the water-to-air mass electronic stopping power ratio in the proton beams, (S<sub>w,</sub><sub>air</sub>)<sub>p</sub> be calculated using the quality parameter R<sub>res</sub>, in expression</p><disp-formula id="scirp.55434-formula14"><label>(14)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/55434x20.png"  xlink:type="simple"/></disp-formula><p>where a = 1.137; b = −4.3・E<sup>−05</sup> and c = 1.84・E<sup>−03</sup>.</p><p>At present, TRS 398 recommends for the water-to-air mass electronic stopping power ratio in the carbon ions beams a constant value of the (s<sub>w</sub><sub>,air</sub>)<sub>i.c.</sub> = 1.13. Calculus performed with SRIM gives the value of (s<sub>w</sub><sub>,air</sub>)<sub>i.c.</sub> = 1.14.</p><p>In this case, the mean ratio of mass electronic stopping powers of the water medium to air, (s<sub>w</sub><sub>,air</sub>)<sub>Qo</sub> = 1.133 in the Co-60 calibration beam-IAEA TRS 398 recommended value, calculated by Andreo using mono-energetic electron stopping power data tabulated in ICRU Report 37 [<xref ref-type="bibr" rid="scirp.55434-ref26">26</xref>].</p><p><xref ref-type="fig" rid="fig4">Figure 4</xref> presents the distribution of the stopping power for carbon ions in the clinical energy range of 50 MeV/u to 450 MeV/u [<xref ref-type="bibr" rid="scirp.55434-ref27">27</xref>].</p><p>Stopping power formulas for heavy charged particles and for electrons and positrons are given in NBSIR 82-2550-A [<xref ref-type="bibr" rid="scirp.55434-ref28">28</xref>] and in ICRU 49 [<xref ref-type="bibr" rid="scirp.55434-ref29">29</xref>].</p></sec><sec id="s3_3"><title>3.3. Absorbed Dose for Hadrons When k<sub>Q</sub><sub>,Qo</sub> Is Known<sub> </sub></title><p>Protons. Factor k<sub>Q</sub><sub>,Qo </sub>value for protons are calculated by Equation (4) as a function of the beam quality index</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Stopping-power ratios as a function depth in water for carbon ions [<xref ref-type="bibr" rid="scirp.55434-ref27">27</xref>]</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/55434x21.png"/></fig><p>R<sub>res</sub> defined as (IAEA 2000 TRS-398) R<sub>res</sub> = R<sub>p</sub> ? z, where R<sub>p</sub> is the practical range and z is the depth of measurement. R<sub>res</sub> is related to the most probable energy of the highest proton energy peak in the spectrum. The beam quality correction factor for the PTW chambers within the STARDOOR laboratory, calibrated at PTB, are given in <xref ref-type="table" rid="table6">Table 6</xref> for protons.</p><p>Having the calibration factor for PTW ionization chamber determined by PTB with the values in <xref ref-type="table" rid="table3">Table 3</xref> or for other types, as per TRS 398 and Formula (2), the absorbed dose in the proton beam is determined.</p><p>Carbon Ions. The values for factor k<sub>Q,Qo</sub> for carbon ions calculated in case of cylindrical and plane-parallel chambers of Markus type within STARDOOR lab, are presented in <xref ref-type="table" rid="table4">Table 4</xref>.</p></sec><sec id="s3_4"><title>3.4. The Absorbed Dose for Hadrons When k<sub>Q,Qo</sub> Is Not Known</title><p>Protons. In case of proton and carbon ion beams, for the ratio of stopping power water to air, TRS 398 recommends the value of (s<sub>w,air</sub>)<sub>Qo</sub> = 1.13 in <sup>60</sup>Co gamma radiation according ratios of stopping powers water/air for heavy ions calculated using the computer codes developed by Salamon, Hiraoka and Bichsel. Data for protons and He are from ICRU-49.</p><p>To calculate the values of factor k<sub>Q</sub><sub>,Qo</sub>, from the denominator of its expression, all the three are known: (s<sub>w</sub><sub>,air</sub>)<sub> Qo</sub> = 1.133, (W<sub>air</sub>/e)<sub>Qo</sub> = 33.97 J/C and the third one is in <xref ref-type="table" rid="table5">Table 5</xref> (TRS 398). The table presents only the data for the ionization chambers within the STARDOOR lab. For the parameters at factor k<sub>Q,Qo </sub>expression denominator, the values recommended in<sub> </sub>TRS398 are selected, namely: (W<sub>air</sub>/e)<sub>Qp</sub> = 34.23 J/C, factor p<sub>Q</sub> ≈ 1 and factor (s<sub>w</sub><sub>,air</sub>)<sub>Qp</sub> shall be calculated in function of the hadron kinetic energy.</p><p>So, the factors related to the qualities of Co-60 calibration beam are data calculated and presented in TRS 398.</p><p>Carbon Ions. Knowing the calibration factor of the ionization chamber in <sup>60</sup>Co beam and the other factors which characterize the calibration beam, the quality parameters of the carbon ion beam need to be determined. For carbon ion, TRS 398 recommends the following values: (W<sub>air</sub>/e)<sub>c.i.</sub> = 34.50 J/C, p<sub>Q,c.i.</sub> = 1 and (s<sub>w</sub><sub>,air</sub>)<sub>Qp</sub> is calculated in function of the carbon ion kinetic energy.</p></sec></sec><sec id="s4"><title>4. Uncertainties</title><p>IAEA TRS 398 recommends for calibration beam specific factors Q<sub>o</sub> (≡Co-60) the following uncertainty (U) values for s<sub>w</sub><sub>,air</sub> in Co-60 beam:</p><p>-STPR: (s<sub>w</sub><sub>,air</sub>)<sub>Qo</sub> = 1.133% &#177; 0.1%, for dry air and humid;</p><p>-the mean energy expanded in air per ion pair formed: (W<sub>air</sub>/e)<sub>Qo</sub> = 33.97 J/C &#177; 0.2%;</p><p>-p<sub>Qo</sub> the calculus method is given in [<xref ref-type="bibr" rid="scirp.55434-ref18">18</xref>].</p><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Calculated values of k<sub>Q,Qo</sub> for proton beams [IAEA TRS 398]</title></caption><table><tbody><thead><tr><th align="center" valign="middle"  rowspan="2"  >Cylindrical chambers</th><th align="center" valign="middle"  colspan="5"  >Beam quality R<sub>res</sub> (g/cm<sup>2</sup>)</th></tr></thead><tr><td align="center" valign="middle" >0.25</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >30</td></tr><tr><td align="center" valign="middle" >PTW 31002 flexible</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.030</td><td align="center" valign="middle" >1.028</td><td align="center" valign="middle" >1.028</td><td align="center" valign="middle" >1.027</td></tr><tr><td align="center" valign="middle" >PTW 31014 PinPoint</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.026</td><td align="center" valign="middle" >1.024</td><td align="center" valign="middle" >1.024</td><td align="center" valign="middle" >1.023</td></tr><tr><td align="center" valign="middle" >PTW 23332 rigid</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.029</td><td align="center" valign="middle" >1.027</td><td align="center" valign="middle" >1.027</td><td align="center" valign="middle" >1.026</td></tr><tr><td align="center" valign="middle" >PTW 30010 Farmer</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.031</td><td align="center" valign="middle" >1.029</td><td align="center" valign="middle" >1.029</td><td align="center" valign="middle" >1.028</td></tr><tr><td align="center" valign="middle"  rowspan="2"  >Plan parallel chambers</td><td align="center" valign="middle"  colspan="5"  >Beam quality R<sub>res</sub> (g/cm<sup>2</sup>)</td></tr><tr><td align="center" valign="middle" >0.25</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >10</td><td align="center" valign="middle" >20</td><td align="center" valign="middle" >30</td></tr><tr><td align="center" valign="middle" >Markus</td><td align="center" valign="middle" >1.009</td><td align="center" valign="middle" >1.004</td><td align="center" valign="middle" >1.002</td><td align="center" valign="middle" >1.002</td><td align="center" valign="middle" >1.001</td></tr><tr><td align="center" valign="middle" >Roos</td><td align="center" valign="middle" >1.008</td><td align="center" valign="middle" >1.003</td><td align="center" valign="middle" >1.001</td><td align="center" valign="middle" >1.001</td><td align="center" valign="middle" >1.000</td></tr></tbody></table></table-wrap><table-wrap id="table4" ><label><xref ref-type="table" rid="table4">Table 4</xref></label><caption><title> Calculated values for k<sub>Q,Qo</sub> for heavy ion beams</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Cylindrical chambers</th><th align="center" valign="middle" >k<sub>QQo</sub></th></tr></thead><tr><td align="center" valign="middle" >PTW 23332 rigid</td><td align="center" valign="middle" >1.029</td></tr><tr><td align="center" valign="middle" >PTW 30001/30010 Farmer</td><td align="center" valign="middle" >1.031</td></tr><tr><td align="center" valign="middle" >PTW 31014 PinPoint</td><td align="center" valign="middle" >1.026</td></tr><tr><td align="center" valign="middle" >PTW 34045 Markus</td><td align="center" valign="middle" >1.004</td></tr><tr><td align="center" valign="middle" >Plan parallel chambers</td><td align="center" valign="middle" >k<sub>QQo</sub></td></tr><tr><td align="center" valign="middle" >PTW 34001 Roos</td><td align="center" valign="middle" >1.003</td></tr><tr><td align="center" valign="middle" >PTW 31010 Farmer</td><td align="center" valign="middle" >1.003</td></tr></tbody></table></table-wrap><table-wrap id="table5" ><label><xref ref-type="table" rid="table5">Table 5</xref></label><caption><title> Values for the factors p and s<sub>w,air</sub>p<sub>Qo</sub> in <sup>60</sup>C gamma radiation [IAEA TRS 398]</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Ionization chamber type</th><th align="center" valign="middle" >p<sub>dis</sub></th><th align="center" valign="middle" >p<sub>wall</sub></th><th align="center" valign="middle" >p<sub>cel</sub></th><th align="center" valign="middle" >s<sub>w,air </sub>p<sub>Qo </sub></th></tr></thead><tr><td align="center" valign="middle"  colspan="5"  >Cylindrical chamber</td></tr><tr><td align="center" valign="middle" >PTW 23323 micro</td><td align="center" valign="middle" >0.993</td><td align="center" valign="middle" >1.001</td><td align="center" valign="middle" >0.993</td><td align="center" valign="middle" >1.119</td></tr><tr><td align="center" valign="middle" >PTW 30001/30010 Farmer</td><td align="center" valign="middle" >0.988</td><td align="center" valign="middle" >1.001</td><td align="center" valign="middle" >0.993</td><td align="center" valign="middle" >1.113</td></tr><tr><td align="center" valign="middle" >PTW 31002 flexible</td><td align="center" valign="middle" >0.989</td><td align="center" valign="middle" >1.001</td><td align="center" valign="middle" >0.993</td><td align="center" valign="middle" >1.114</td></tr><tr><td align="center" valign="middle" >PTW 31014 Pin Point</td><td align="center" valign="middle" >0.996</td><td align="center" valign="middle" >0.998</td><td align="center" valign="middle" >0.993</td><td align="center" valign="middle" >1.118</td></tr><tr><td align="center" valign="middle"  colspan="5"  >Plane-parallel chamber</td></tr><tr><td align="center" valign="middle" >PTW 34045 Markus</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.009</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.144</td></tr><tr><td align="center" valign="middle" >PTW 34001 Roos</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.010</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.145</td></tr></tbody></table></table-wrap><p>Regarding proton beams, IAEA TRS 398 recommends the following values:</p><p>-(s<sub>w.air</sub>)<sub>p</sub> are calculated as a function of the energy and are presented in 2.4 Paragraph;</p><p>-(W<sub>air</sub>/e)<sub>p</sub> = 34.23 J/C &#177; 1.5%, (W<sub>air</sub>/e)<sub>p</sub> = 34.8 J/C &#177; 0.7% for dry air and humid air, respectively. In the case of proton beam ICRU 59 recommends (W<sub>air</sub>/e)<sub>p</sub> = 34.80 J/C &#177; 0.7%.</p><p>-p<sub>Q</sub> ≈1 for protons and carbon ions.</p><p>Estimated relative uncertainty for proton beam are presented in <xref ref-type="table" rid="table6">Table 6</xref> [<xref ref-type="bibr" rid="scirp.55434-ref30">30</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref31">31</xref>].</p><p>In terms of heavy ion beam sIAEA TRS 398 recommends the following values:</p><p>-(s<sub>w</sub><sub>,air</sub>)<sub>c.i.</sub> = 1.13% &#177; 2% [<xref ref-type="bibr" rid="scirp.55434-ref2">2</xref>];</p><p>-(W<sub>air</sub>/e)<sub>c.i.</sub> (weighted median) = 34.5 J/C &#177; 1.5%;</p><p>-p<sub>,c.i.</sub> = 1.0% &#177; 1% [<xref ref-type="bibr" rid="scirp.55434-ref2">2</xref>] [<xref ref-type="bibr" rid="scirp.55434-ref10">10</xref>];</p><p>Estimated relative uncertainty for carbon ion beams are presented in <xref ref-type="table" rid="table7">Table 7</xref> [<xref ref-type="bibr" rid="scirp.55434-ref31">31</xref>].</p><table-wrap id="table6" ><label><xref ref-type="table" rid="table6">Table 6</xref></label><caption><title> Estimated relative uncertainties (in %) for the quality factors for proton beams [IAEA TRS 398]</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Protons</th><th align="center" valign="middle"  colspan="2"  >Cylindrical chambers</th><th align="center" valign="middle"  colspan="2"  >Plane-parallel chambers</th></tr></thead><tr><td align="center" valign="middle" >Component</td><td align="center" valign="middle" >Protons</td><td align="center" valign="middle" ><sup>60</sup>Co + protons</td><td align="center" valign="middle" >Protons</td><td align="center" valign="middle" ><sup>60</sup>Co + protons</td></tr><tr><td align="center" valign="middle" >s<sub>w,air</sub></td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1.2</td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1.2</td></tr><tr><td align="center" valign="middle" >W<sub>air</sub>/e<sub> </sub></td><td align="center" valign="middle" >0.4</td><td align="center" valign="middle" >0.5</td><td align="center" valign="middle" >0.4</td><td align="center" valign="middle" >0.5</td></tr><tr><td align="center" valign="middle" >p<sub>Q</sub><sub> </sub>(combined)</td><td align="center" valign="middle" >0.8</td><td align="center" valign="middle" >1.1</td><td align="center" valign="middle" >0.7</td><td align="center" valign="middle" >1.7</td></tr><tr><td align="center" valign="middle" >Total uncertainy in k<sub>Q,Qo</sub></td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >1.7</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >2.1</td></tr></tbody></table></table-wrap><table-wrap id="table7" ><label><xref ref-type="table" rid="table7">Table 7</xref></label><caption><title> Estimate relative uncertainties (in %) for the quality factors for carbon ion beams [IAEA TRS 398]</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Light ions</th><th align="center" valign="middle"  colspan="2"  >Cylindrical chambers</th><th align="center" valign="middle"  colspan="2"  >Plane-parallel chambers</th></tr></thead><tr><td align="center" valign="middle" >Component</td><td align="center" valign="middle" >Light ions</td><td align="center" valign="middle" ><sup>60</sup>Co + light ions</td><td align="center" valign="middle" >Light ions</td><td align="center" valign="middle" ><sup>60</sup>Co + light ions</td></tr><tr><td align="center" valign="middle" >s<sub>w,air</sub></td><td align="center" valign="middle" >2.0</td><td align="center" valign="middle" >2.1</td><td align="center" valign="middle" >2.0</td><td align="center" valign="middle" >2.1</td></tr><tr><td align="center" valign="middle" >W<sub>air</sub>/e<sub> </sub></td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >1.5</td><td align="center" valign="middle" >1.5</td></tr><tr><td align="center" valign="middle" >p<sub>Q</sub> (combined)</td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1.0</td><td align="center" valign="middle" >1.8</td></tr><tr><td align="center" valign="middle" >Total uncertainty in k<sub>Q,Qo</sub></td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >2.8</td><td align="center" valign="middle" >-</td><td align="center" valign="middle" >3.2</td></tr></tbody></table></table-wrap></sec><sec id="s5"><title>5. Conclusions</title><p>The purpose of this paper is to offer a synthesis of all the data required to determine the absorbed dose in water in proton and carbon ion beams, also satisfying the recommendations in TRS 398.</p><p>These data allow the outfitting of STARDOOR Lab with the dosimetric equipment required to undergo measurements in proton and heavy ion beams and the finalization of some cross-interpretations with other labs and centers of clinic hadron-based therapy abroad.</p><p>These preliminary data may be used to elaborate and implement a technical procedure for the determination of the absorbed dose in hadron beams for an operation point of a conventional acceleration system or an operational point of a laser system.</p><p>Moreover, these exploratory studies are necessary and useful for establishing some methods to generate clinical hadron beams (protons and carbon ions for which a rich experience already exists in Europe and worldwide) by means of the 10 PW laser beam that is to be finalized on the Magurele Platform-Bucharest (Romania).</p></sec><sec id="s6"><title>Cite this paper</title><p>F. Scarlat,A. Scarisoreanu,E. Badita,C. Vancea,I. I. Calina,Fl. Scarlat,N. Verga, (2015) Ionization Chamber Dosimetry for Conventional and Laser-Driven Clinical Hadron Beams. Journal of Biosciences and Medicines,03,8-17. doi: 10.4236/jbm.2015.34002</p></sec></body><back><ref-list><title>References</title><ref id="scirp.55434-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Ciorascu, F., et al. (1962) Some Problems of the Commissioning and the Adjusting of the Betatron from the Institute of Atomic Physics. St. Cerc. Fiz., 15, 11, 105.</mixed-citation></ref><ref id="scirp.55434-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Scarlat, F. (1971) Adaptation of the 30 MeV IAP Betatron for Medical Therapy. The 5th International Betatron Symposium, Bucharest-Magurele, Romania, 18-23 October 1971.</mixed-citation></ref><ref id="scirp.55434-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Birzu, I., Grigorescu, St. and Scarlat, F. (1973) Therapeutic and Dosimetric Aspects in the Treatment of Malignant Tumours with a 30 MeV Betatron. The International Conference on Photonuclear Reactions and Applications, Asilomar Livermore, 26-30 March 1973.</mixed-citation></ref><ref id="scirp.55434-ref4"><label>4</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Scarlat</surname><given-names> F. </given-names></name>,<etal>et al</etal>. (<year>1992</year>)<article-title>A 40 MeV Medical Betatron. Rev. Roum. Phys</article-title><source>Tome</source><volume> 37</volume>,<fpage> 615</fpage>-<lpage>619</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.55434-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Baltateanu, N., et al. (1969) L’accelerateur lineaire a’electrons de 3 MeV. preprint IFA, AL-1, 3-16.</mixed-citation></ref><ref id="scirp.55434-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Haltrich, S. and Scarlat, F. (1967) Parametrii betatronului IFA de 8 MeV. Raport intern IFA, MB-178, 10 Decembrie 1967.</mixed-citation></ref><ref id="scirp.55434-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Haltrich, S., Ivanovici, M., Iliescu, C., Panaitescu, I., Mohor, I. and Scarlat, F. (1970) Ein 8 MeV Betatron Mit Verbesserten Magnetkreis. Kernenergie, Band 13, H.1, S.16-24.</mixed-citation></ref><ref id="scirp.55434-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Baciu, G., Panaitescu, I., Mohor, I., Scarlat, F. and Andreescu, M. (1971) Romanian Industrial Betatron BETI for Non-destructive Testing. The 5th International Betatron Symposium, Bucharest-Magurele, 18-23 October 1971.</mixed-citation></ref><ref id="scirp.55434-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Axinescu, S., et al. (1982) The 17-Orbit Microtron of the Institute of Atomic Physics. All Union Symposium on microtrons and Their Applications, Dubna, U.S.S.R.</mixed-citation></ref><ref id="scirp.55434-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Minea, R., et al. (2004) Accelerators Use for Irradiation Offers Medicinal Herbs. Proc. of EPAC, Lucerne, 2004, 2371-2373.</mixed-citation></ref><ref id="scirp.55434-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Martin, D., et al. (2006) Waste Treatment by Microwave and Electron Beam Irradiation. Proc. of the Environmental Physics Conference, Alexandria, 18-22 February 2006, 91-100.</mixed-citation></ref><ref id="scirp.55434-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Scarlat, F., Scarisoreanu, A., Minea, R., Badita, E., Sima, E., Dumitrascu, M., Stancu, E. and Vancea, C. (2013) Secondary Standard Dosimetry Laboratory at INFLPR. Optoelectronics and Advanced Materials—Rapid Communications, Vol.7, 618-624.</mixed-citation></ref><ref id="scirp.55434-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Zamfir, N.V. (2012) Extreme Light Infrastructure—Nuclear Physics ELI-NP. Experimental Programme Workshop at ELI-NP, Bucharest, 3-5 October 2012.</mixed-citation></ref><ref id="scirp.55434-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Scarlat, F., Verga, N., Scarisoreanu, A., Badita, E., Dumitrascu, M., Stancu, E., Vancea, C. and Scarlat, Fl. (2013) Absorbed Dose Determination in Conventional and Laser-Driven Hadron Clinical Beams. Journal of Intense Pulsed Lasers and Applications in Advances Physics, 3, 5-25.</mixed-citation></ref><ref id="scirp.55434-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Bulanov, S.V. and Khoroshkov, V.S. (2002) Feasibility of Using Laser Ion Accelerators in Proton Therapy. Plasma Physics Reports, 28, 453-456. http://dx.doi.org/10.1134/1.1478534</mixed-citation></ref><ref id="scirp.55434-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Scarlat, F., Scarisoreanu, A., Verga, N., Scarlat, Fl. and Vancea, C. (2014) Evaluation of Physical Parameters for Laser-Driven Clinical Hadron Beams. Journal of Intense pulsed Lasers and Applications in Advances Physics, 4, 55-64.</mixed-citation></ref><ref id="scirp.55434-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">ICRU Report 21 (1974) Radiation Dosimetry: Electrons with Initial Energies between 1 and 50 MeV. Quantities and Units. International Commission on Radiation Units and Measurements, Washington D.C.</mixed-citation></ref><ref id="scirp.55434-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">IAEA TRS 398. Absorbed Dose Determination in External Beam Radiotherapy. An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Tehnical Report no 398.</mixed-citation></ref><ref id="scirp.55434-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">IAEA TRS 277. Absorbed Dose Determination in Photon and Electron Beams. An international Code of Practice. Tehnical Report of Series no. 277, Vienna, 1997.</mixed-citation></ref><ref id="scirp.55434-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">ICRU Report 59 (1998) Clinical Proton Dosimetry—Part I: Beam Production, Beam Delivery and Measurement of Absorbed Dose, International Commission on Radiation Units and Measurements, Bethesda, Maryland, USA.</mixed-citation></ref><ref id="scirp.55434-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Hartmann, G.H., Jakel, O., Heeg, P., Karger, C.P. and Kriesβbach, A. (1999) Determination of Water Absorbed Dose in a Carbon Ion Beam Using Thimble Ionization Chambers. Phys. Med. Biol., 444.</mixed-citation></ref><ref id="scirp.55434-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Vatnitsky, S., et al. (1999) Proton Dosimetry Intercomparation Based on the ICRU Report 59 Protocol. Rad and Oncol., 51, 273-279. http://dx.doi.org/10.1016/S0167-8140(99)00060-2</mixed-citation></ref><ref id="scirp.55434-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">IAEA TRS 381. The Use Plan Parallel Ionization Chambers in High Energy Electron and Photon Beams. An International Code of Practice for Dosimetry. Tehnical Report Series no. 381, Vienna, 1995.</mixed-citation></ref><ref id="scirp.55434-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">The Normalized (at Peak) Bragg Curves for Various Proton Incident Energies in Water Phantom: A Simulation with GEANT4 Monte Carlo Code, Abstract ID: 8159. http://www.aapm.org/meetings/amos2/pdf/34-8159-78594-298.pdf</mixed-citation></ref><ref id="scirp.55434-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Karger, C.P., Jakel, O., Palmans, H. and Kanal, T. (2010) Dosimetry for Ion Beam Radiotherapy. Phys. Med. Biol., R193-R234. http://dx.doi.org/10.1088/0031-9155/55/21/R01</mixed-citation></ref><ref id="scirp.55434-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">ICRU Report 37 (1984) Stopping Powers for Electrons and Po-sitrons. International Commission on Radiation Units and Measurements, Bethesda, MD, USA.</mixed-citation></ref><ref id="scirp.55434-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Geithner, O., Andreo, P., Sobolevsky, N., Hartman, G. and Jakel, O. (2006) Calculating of Stopping Power Ratios for Carbon Ions Dosimetry. Phys. Med. Biol., 51, 2279-2292. http://dx.doi.org/10.1088/0031-9155/51/9/012</mixed-citation></ref><ref id="scirp.55434-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Berger, M.J. and Seltzer, S.M. (1983) Stopping Powers and Ranges of Electrons and Positrons, National Bureau of Standards NBSIR 82-2550-A, Washington D.C.</mixed-citation></ref><ref id="scirp.55434-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">ICRU Report 49 (1993) Stopping Powers and Ranges for Protons and Alpha Par-ticles, International Commission on Radiation Units and Measurements, Bethesda, Maryland, USA.</mixed-citation></ref><ref id="scirp.55434-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">IAEA TEDOC 1455. Implementation of the International Code of Practice on Dosimetry in Radiotherapy (TRS 398). Review and Testing. International Atomic Energy Agency, Vienna, 2005.</mixed-citation></ref><ref id="scirp.55434-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">IAEA TEDOC 1585. Measurements Uncertanity. A Practical Guide for Secondary Standard Dosimetry Laboratories. Vienna, 2008.</mixed-citation></ref></ref-list></back></article>