<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JBNB</journal-id><journal-title-group><journal-title>Journal of Biomaterials and Nanobiotechnology</journal-title></journal-title-group><issn pub-type="epub">2158-7027</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jbnb.2015.62009</article-id><article-id pub-id-type="publisher-id">JBNB-54932</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Nanomodificated Surface CoCr Alloy for Corrosion Protection of MoM Prosthesis
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ristina</surname><given-names>Díaz</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Stephan</surname><given-names>Mändl</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Rosario</surname><given-names>Pereiro</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Beatriz</surname><given-names>Fernández</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Surface Engineering Technological Center, Association of Navarra Industry, Pamplona, Spain</addr-line></aff><aff id="aff2"><addr-line>Leipzig Institute of Surface Modification, Leipzig, Germany</addr-line></aff><aff id="aff3"><addr-line>Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Oviedo, Spain</addr-line></aff><pub-date pub-type="epub"><day>12</day><month>03</month><year>2015</year></pub-date><volume>06</volume><issue>02</issue><fpage>91</fpage><lpage>99</lpage><history><date date-type="received"><day>24</day>	<month>February</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>18</month>	<year>March</year>	</date><date date-type="accepted"><day>24</day>	<month>March</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Problems in metal-on-metal (MoM) hip replacement systems still persist due to high wear rates, low corrosion resistance and release of toxic ions and nanoparticles. As a consequence of these effects, failure, infections, loosening or bone resorption is the typical problems in the hip prosthesis. In order to reduce failure due to corrosion and/or releasing ions and particles, this study presents some works in a novel nanoscale surface modification of cobalt-chromium alloy (CoCr) for obtaining improved surface conditions in these alloys for these applications. Improving corrosion resistant of these alloys and achieving a low wear rate are possible to reduce the total released ions and particles released from the surface of this material. According to it, three different treatments using oxygen at temperatures of 300&amp;degC, 350&amp;degC and 400
  &amp;degC were carried out by plasma immersion ion implantation technique (PI3). X-ray diffraction (XRD) analysis shows an increase in the formation of chromium oxides in the outer surface of the CoCr alloy. It allows improving in corrosion resistant in CoCr alloys. Moreover, total quantity of released Co, Cr and Mo ions have been reduced. Wear rate studies showed a very similar behaviour after the treatments in relation to untreated CoCr alloy and release rate from the treated surface of CoCr alloys was reduced in comparison with untreated CoCr alloy.
 
</p></abstract><kwd-group><kwd>Plasma Immersion Ion Implantation</kwd><kwd> THR</kwd><kwd> Nanoparticles</kwd><kwd> Ion Release</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Every year, about one million patients worldwide undergo total hip arthroplasty (THA) surgery. This is considered a successful, safe and cost-effective medical intervention to restore functionality of the hip joint and to regain pain-free mobility in patients suffering from severe joint disease or trauma. The number of people undergoing primary a total hip arthroplasty (THA) and revision surgery is expected to increase further due to an ageing population, decreasing average age at the first operation and the limited life span of prostheses [<xref ref-type="bibr" rid="scirp.54932-ref1">1</xref>] .</p><p>In most industrialised countries, THA has an incidence higher than 150 procedures per 100,000 habitants and year [<xref ref-type="bibr" rid="scirp.54932-ref2">2</xref>] . In general, about one million of hips are replaced by artificial prostheses around the world every year. Only in the United States, it is extrapolated that the increasing number of primary THA and revision procedures will increase the annual cost from 8.43 billion $ in 2003 to 22.7 billion $ in 2030 [<xref ref-type="bibr" rid="scirp.54932-ref3">3</xref>] .</p><p>Wear is recognized as the most important limitation to long term stability of hip devices. THA has been reported to fail in younger patients with more active lifestyles [<xref ref-type="bibr" rid="scirp.54932-ref4">4</xref>] . Hip resurfacing (HR) is proposed as a bone- conserving alternative to the conventional THA for young and active patients after optimal medical therapy fails [<xref ref-type="bibr" rid="scirp.54932-ref5">5</xref>] .</p><p>Metals such as stainless steels (SS), titanium alloys (Ti) and CoCr alloys are required in orthopaedic applications because they exhibit elevated mechanical strength and fracture toughness. Recently, the metallic materials most used in MoM hip prosthesis are Ti and CoCr alloys [<xref ref-type="bibr" rid="scirp.54932-ref6">6</xref>] . Ti alloys are considered as one of the most biocompatible metals, and they present an excellent corrosion resistance but poor mechanical properties. On the other hand, CoCr alloys exhibit elevated mechanical properties and good corrosion resistance under friction condition [<xref ref-type="bibr" rid="scirp.54932-ref7">7</xref>] , what apparently made it most suitable for MoM hip prosthesis with lower wear rates than titanium-ultrahigh molecular weight polyethylene (Ti-UHMWPE) wear couples [<xref ref-type="bibr" rid="scirp.54932-ref8">8</xref>] .</p><p>One of the most advanced hip replacements is the Birmingham Hip Resurfacing system (BHR) in its type of a metal on metal (MoM) joint [<xref ref-type="bibr" rid="scirp.54932-ref9">9</xref>] [<xref ref-type="bibr" rid="scirp.54932-ref10">10</xref>] . However, recent information about the wear of certain metal-on-metal devices has raised concerns about their use. By 2010, reports in the orthopaedic literature have increasingly cited the problem of early failure of metal on metal prostheses in a small percentage of patients [<xref ref-type="bibr" rid="scirp.54932-ref11">11</xref>] . Failures may relate to release of minute metallic particles or metal ions from wear of the implants, causing pain and disability severe enough to require revision surgery in 1% - 3% of patients [<xref ref-type="bibr" rid="scirp.54932-ref12">12</xref>] .</p><p>However, common concerns with all MoM hip prostheses are related to the unclear role of long-term exposure to metal ions released into the human body. Wear and corrosion effects of MoM implants are still judged on the basis of metal-ion concentrations revealed in blood, serum or urine [<xref ref-type="bibr" rid="scirp.54932-ref13">13</xref>] . These ions act highly specific when inducing a tissue response. Over the time, the level of metal ions may become clinically significant, resulting in implant failure, osteolysis, and allergic reactions [<xref ref-type="bibr" rid="scirp.54932-ref5">5</xref>] . For cobalt ions (Co<sup>2+</sup>), multiple pathways have been identified depending on the local concentration, including apoptosis, increased expression of the hypoxia-inducible factor-1(HIF-1α) for endothelial cells [<xref ref-type="bibr" rid="scirp.54932-ref14">14</xref>] and increased osteoclasts activity [<xref ref-type="bibr" rid="scirp.54932-ref15">15</xref>] .</p><p>A multitude of biomedical processes are activates by nanoscopic wear particles. In the vicinity of protheses, stimulation of macrophages and lymphocytes to pro produce proinflammatory mediators is observed, leading to enhanced osteoclast formation, with increased osteolysis of bone material [<xref ref-type="bibr" rid="scirp.54932-ref16">16</xref>] -[<xref ref-type="bibr" rid="scirp.54932-ref18">18</xref>] . Additionally, the transformation of macrophages towards osteoclast-like cells which resorb bone was observed after phagocytosing wear particles [<xref ref-type="bibr" rid="scirp.54932-ref19">19</xref>] . Spreading across the whole body and accumulation in vital organs, as spleen, liver and lung has been reported with negative effects [<xref ref-type="bibr" rid="scirp.54932-ref20">20</xref>] [<xref ref-type="bibr" rid="scirp.54932-ref21">21</xref>] . Only a minor influence of the chemistry for nanoparticles is observed here as these processes have been reported for a multitude of different particles [<xref ref-type="bibr" rid="scirp.54932-ref22">22</xref>] [<xref ref-type="bibr" rid="scirp.54932-ref23">23</xref>] . Additional problems can arise from incomplete surface repassivation after tribological processes destroy an oxide passivation layer and exposes fresh material to corrosion leading to the creation of new, brittle oxide on the surface which is then leading to even more particles [<xref ref-type="bibr" rid="scirp.54932-ref7">7</xref>] .</p><p>While downstream biochemical regulation to prevent such negative influences of wear particles have been reported recently [<xref ref-type="bibr" rid="scirp.54932-ref24">24</xref>] , a more practical route involves advanced surface modification techniques to alleviate these problems. However, conformality, defect density and adhesion aspects have to be considered when choosing a suitable method for surface modification. Plasma immersion ion implantation technique (PI3) is one possibility where synergy effects from simultaneous improvements in topology, tribology and corrosion behaviour can be obtained for biomaterials [<xref ref-type="bibr" rid="scirp.54932-ref25">25</xref>] -[<xref ref-type="bibr" rid="scirp.54932-ref27">27</xref>] . The present study describes the surface modification of F-799 CoCr alloy using oxygen PI3. In this work, low ion energies and low temperatures (300˚C - 400˚C) were studied, to prevent changes in the microstructure of the bulk material while obtaining excellent corrosion resistance at the surface. Additionally, wear rate and released ions were studied in CoCr alloys after using the proposed surface treatment and these experimental results were compared to those obtained with CoCr alloys without treatment. The aim of this study is to establish treatment conditions to obtain the best protection properties on the surfaces of CoCr alloys in order to reduce the release of ions from its surface. The modified surface topography was of less importance as the articulating surfaces and not the surface for bone and tissue integrating were targeted in this experiment.</p></sec><sec id="s2"><title>2. Experimental</title><p>A medical grade CoCrMo ASTM F-799 alloy was obtained as a commercial material. All the samples were mirror polished with a 1 mm diamond suspension and cleaned in an acetone ultrasonic bath before making the different treatments. Oxygen PI3 experiments were carried out in a HV chambers at a base pressure lower than 10<sup>−4</sup> Pa and a working pressure of 0.2 Pa. The plasma for oxygen implantations was generated by an RF plasma source operating at 40.68 MHz. For these experiments, a voltage pulse of 10 kV was used, with a total incident fluency of 6 &#215; 10<sup>18</sup> oxygen atoms・cm<sup>−2</sup> during a processing time of 1 h. at temperatures of 300˚C, 350˚C and 400˚C. The process temperature was determined with a pyrometer calibrated against a thermocouple above space of samples [<xref ref-type="bibr" rid="scirp.54932-ref28">28</xref>] .</p><p>Quantitative depth-profiles of different elements were measured by glow discharge optical emission spectroscopy (GD-OES) using a JY GD Profiler HR (Jobin-Yvon Horiba, France) with RF source operating at 650 Pa and 40 W. Corrections were applied to the optical signals in order to take into account the influence of the residual hydrogen signal. Our interest was to evaluate possible changes in depth profile analysis after corrosion tests. Then, it could be possible to estimate movements or displacements of Co, Cr and Mo ions inside the material after the treatment.</p><p>Corrosion tests were conducted under ASTM G5-94 standard, at 37˚C &#177; 0.2˚C using bovine serum (BSA), containing 20 - 23 g∙l<sup>−1</sup> of proteins. A conventional three-electrodes cell with a Pt wire as counter-electrode (CE), an Ag/AgCl electrode as reference electrode (RE) and implanted sample as working electrode (WE) were prepared. Electrodes were connected to a Gamry Instrument set-up which was used to record polarisation curves. Samples were loaded into the electrochemical cell after being recovered with resin, except for an area of 0.125 cm<sup>2</sup>. After 20 minutes of immersion in BSA, open-circuit specimen potentials (OCP) were obtained. After that, samples were immersed and potential scan limited between &#177;300 mV was started. In all experiments, polarisation potential sweep rate was kept to 0.17 mV∙s<sup>−1</sup>.</p><p>Moreover, these surfaces were studied by tribocorrosion tests using serum bovine (BSA) controlled at pH 7.0 and 37˚C &#177; 0.2˚C. Tribocorrosion tests were carried out by Microtest MT/30/NI equipment in ball-on-disk configuration. Treated samples were tested against a counterpart of F-799 CoCr alloy without any treatment. After tribocorrosion tests: a) for one hand, the volume loss in the wear track was measured by using an optical profilometer WYCO RST 500 and wear rates was calculated for each sample, and b) for another hand, rests of bovine serum using during the wear tests (BSA) were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) using an equipment from Agilent (7500 c) in order to determinate quantity of metal ions released during wear tests. Furthermore, an x-ray diffraction system (XRD) Siemens D-5000 (Cu Kα (λ = 0.1540 nm radiation) analysis using a grazing angle of 0.5˚ were carried out to establish the oxides formed in the surfaces after each treatment.</p></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. GD-OES Analysis</title><p>Oxygen implantation into CoCr alloy has found to reduce Co, Cr and Mo concentrations in the immediate surface. However, while Cr and Mo started around 5 nm increasing until the corresponding values of the reference samples were reached, the profiles of Co after treatment showed a reduction around 30% - 50% until about 5 nm and then around 15 - 30 nm this profiles increased until reference values (<xref ref-type="fig" rid="fig1">Figure 1</xref> and <xref ref-type="fig" rid="fig2">Figure 2</xref>). These reductions were stronger at 300˚C and 400˚C, where they reached 5% of Co until about 30 nm in depth (<xref ref-type="fig" rid="fig2">Figure 2</xref>). Hence, a strong oxygen induced surface segregation of the alloying elements was observed.</p></sec><sec id="s3_2"><title>3.2. Potentiodynamic Polarisation Curves</title><p><xref ref-type="fig" rid="fig3">Figure 3</xref> represents polarisation curves of titanium-aluminium-vanadium (TiAlV) and CoCr alloy references. As can be seen, the current density (icorr) of TiAlV is around two orders of magnitude over the value of the corrosion current density (jcorr) of the reference sample of CoCr alloy. It means, TiAlV is better to corrosion behaviour</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Depth profile analysis of a reference F-799 CoCr alloy obtained by GD-OES</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x5.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Changes of Co, Cr and Mo observed in the depth profile of an F-799 CoCr alloy after PI3 surface modification using oxygen in relation to untreated sample</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x6.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Polarization curves for TiAlV and CoCrMo reference samples and CoCrMo treated samples by oxygen plasma immersion ion implantation in BSA solution at 37.2˚C</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x7.png"/></fig><p>in BSA than CoCr alloys. In order to reduce this difference in corrosion behaviour between both materials, some treatments were carried out over CoCr alloy. <xref ref-type="fig" rid="fig3">Figure 3</xref> represents the improvement in resistant corrosion of treated CoCr alloy in relation to TiAlV without any treatment. All treated CoCr alloys showed similar behaviour to corrosion resistant. Now, the current density between both materials was very similar keeping near in the same order of magnitude. Also, the corrosion potential was slightly superior in treated CoCr. However, although CoCr alloys were improved in resistant corrosion, their polarisation curves presented lower capacity to passivation and recovered after the cycling of corrosion. So, it can be said that CoCr alloy treated by oxygen slightly could have a resistant corrosion excellent in BSA and similar to TiAlV in corrosion.</p></sec><sec id="s3_3"><title>3.3. Wear Tests</title><p>The wear rate of treated CoCr was measured in relation to untreated CoCr (<xref ref-type="table" rid="table1">Table 1</xref>). The surface modification did not change the friction coefficient compared to untreated CoCr alloy. In contrast, the results revealed a wear rate of around 6 - 7 &#215; 10-14 m<sup>3</sup>∙N<sup>−1</sup>・m<sup>−1</sup> for all of samples. In this rate, O (400˚C) treated sample showed the best improvement in wear test in BSA at 37˚C &#177; 0.2˚C, reducing the wear rate by around 15% in relation to untreated CoCr. <xref ref-type="fig" rid="fig4">Figure 4</xref> shows a picture of the collected particles after wear tests of O (400˚C) treated sample in BSA. The size of these particles was between 3.0 - 3.5 &#181;m, the highest ones, and around 100 - 200 nm the smallest ones, approximately. Composition analysis of them by EDS showed some rests of oxygen, cobalt and chromium in their surface (<xref ref-type="fig" rid="fig4">Figure 4</xref>).</p></sec><sec id="s3_4"><title>3.4. Ion Release</title><p>After wear tests the BSA was collected and analysed in two different procedures. On one hand, the collected BSA solution after wear tests was selected, including some particles. On the other hand, BSA solution was filtering out particles under 220 nm and such solution was also analysed by ICP-MS. The results showed a significant influence in the released ions concentration by particles in the solution after wear tests. <xref ref-type="fig" rid="fig5">Figure 5</xref> represents total ion releasing (in ng∙g<sup>−1</sup>, ppb) divided in Co, Cr and Mo concentrations, just after wear tests. As can be seen, the total quantity of released ions from the treated samples was lower than from an untreated sample. <xref ref-type="fig" rid="fig5">Figure 5</xref> shows that the highest reduction in treated samples was for Co ions in relation to untreated samples with more or less no change for the already low release rates of Cr and Mo ions.</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> A collected particle from wear rate of O (400˚C)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x8.png"/></fig><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Wear rate after oxygen treatment of CoCr alloy in relation to untreated sample</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Samples</th><th align="center" valign="middle" >Friction coefficient</th><th align="center" valign="middle" >Wear rate (10<sup>−14</sup> m<sup>3</sup>/Nm)</th></tr></thead><tr><td align="center" valign="middle" >Reference</td><td align="center" valign="middle" >0.26 &#177; 0.01</td><td align="center" valign="middle" >7.20 &#177; 0.80</td></tr><tr><td align="center" valign="middle" >O (300˚C)</td><td align="center" valign="middle" >0.25 &#177; 0.01</td><td align="center" valign="middle" >7.70 &#177; 0.20</td></tr><tr><td align="center" valign="middle" >O (350˚C)</td><td align="center" valign="middle" >0.25 &#177; 0.01</td><td align="center" valign="middle" >7.60 &#177; 0.30</td></tr><tr><td align="center" valign="middle" >O (400˚C)</td><td align="center" valign="middle" >0.26 &#177; 0.01</td><td align="center" valign="middle" >6.00 &#177; 0.20</td></tr></tbody></table></table-wrap><p>After removing particles with a size lower that 220 nm, the total quantity of the different released ions (Co, Cr and Mo) was also reduced. In this case, from the total released ions of the untreated samples, the treated samples reduced their released ions around 15% (<xref ref-type="fig" rid="fig6">Figure 6</xref>). Here, the highest reduced released ion was found to be Cr ion.</p><p>Taking into account experimental results it could established that around 10% of ion release is induced from particles in the medium. As different reductions are found for Co and Cr concentrations, at least two different kinds of particles must be present. Cr<sub>2</sub>O<sub>3</sub> containing particles from the oxide layer comprise one class while particles originating from the base material are also present. The former group should be biomedically inert as Cr(III) is known for rapid formation of insoluble precipitates with a possible grain size of much less than 220 nm. At the same time, relative toxicities of ions and nanoparticles have to be compared with literature data pointing towards more negative effects for particles than ions [<xref ref-type="bibr" rid="scirp.54932-ref29">29</xref>] .</p></sec><sec id="s3_5"><title>3.5. XRD Analysis</title><p><xref ref-type="fig" rid="fig7">Figure 7</xref> shows differences in the XRD analysis of the treated samples and untreated samples. New peaks in the outer surface of the oxygen treated samples are observed. These peaks indicate Cr<sub>2</sub>O<sub>3</sub> forming a passive layer in the surface of the F-799 CoCr alloy. These peaks became smaller and showed a higher intensity with increasing processing temperature, indicating larger crystallites at higher temperatures. Moreover, some weak molybdenum oxides might be observed.</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Comparison of the total released ions obtained by ICP-MS analyses of the unfiltered BSA samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x9.png"/></fig><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Total released ions after filtering of the BSA from wear tests</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x10.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Comparison of XRD analysis of treated samples in relation to untreated samples</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/2-3200385x11.png"/></fig></sec></sec><sec id="s4"><title>4. Summary &amp; Conclusion</title><p>A F-799 CoCr alloy was treated by oxygen PI3 in order to simultaneously improve wear rate and corrosion resistance and as a consequence, ion release rates. The results of this work show a surface modification of about 30 - 40 nm of the structure of CoCr alloy and creation of some superficial oxide [<xref ref-type="bibr" rid="scirp.54932-ref30">30</xref>] . This process introduces an excellent corrosion resistance, similar to TiAlV keeping on similar wear rate factor to the untreated CoCr alloy. As a consequence, a reduction around 10% - 20% of released ions was obtained from these tests using BSA. The average of released Co ions have been reduced while the quantity of Cr and Mo ions are very similar than in CoCr without treating. It could be explain due to Cr and Mo ions are forming oxides after the treatment with oxygen, and only Co ions would remain loose. It might introduce a higher probability in Co releasing than the rest of ions [<xref ref-type="bibr" rid="scirp.54932-ref31">31</xref>] .</p><p>Additional studies characterising the collected wear particles are planned for the future [<xref ref-type="bibr" rid="scirp.54932-ref32">32</xref>] . At the moment after analysing surface of them, some oxides are covering them keeping an inert surface apparently [<xref ref-type="bibr" rid="scirp.54932-ref33">33</xref>] .</p><p>The processing temperature itself was not a significant parameter for the determination of the results. The effectiveness of even higher temperatures has to be investigated while metallurgical transformations of the biomaterial F-799 during processing have to be avoided.</p><p>Moreover, further superficial treatments studies are carrying out in order to attempt to obtain a high reduction in released ions [<xref ref-type="bibr" rid="scirp.54932-ref34">34</xref>] .</p></sec><sec id="s5"><title>Acknowledgements</title><p>The authors would like to thank to the Ministry of Science and Innovaci&#243;n &amp; Navarra Government for FUNCOAT project and to the Ministry of Economy and Competitiveness for MoM for LIFE (MAT2011-29698- C03-02) and for providing financial support to these projects”.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.54932-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Kostov, K.G., Ueda, M., Lepienskyc, M., Soares, P.C., Gomes, G.F., Silva, M.M. and Reuther, H. (2004) Surface Modification of Metal Alloys by Plasma Immersion Ion Implantation and Subsequent Plasma Nitriding. Surface &amp; Coatings Technology, 186, 204-208. http://dx.doi.org/10.1016/j.surfcoat.2004.04.027</mixed-citation></ref><ref id="scirp.54932-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Díaz, C., García, J.A., Mandl, S. and Rodríguez, R.J. (2011) Plasma Immersion Ion Implantation for the Prevention of Metal Ion Release from CoCrMo Alloys. IEEE Issue—Applications and Numerical Simulation of Plasma Surface Modification, 39, 3045-3048.</mixed-citation></ref><ref id="scirp.54932-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Díaz, C., Lutz, J., Mandl, S., García, J.A., Martínez, R., Rodríguez, R.J., Damborenea, J.J., Arenas, M.A. and Conde, A. (2008) Comparison of Tribological Behaviour and Biocompatibility of Ti6Al4V Alloy after Ion Implantation or Thermal Oxidation. Physica Status Solidi (C), 5, 947-951. http://dx.doi.org/10.1002/pssc.200778310</mixed-citation></ref><ref id="scirp.54932-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Korovessis, P., Petsinis, G., Repanti, M. and Repantis, T. (2006) Metallosis after Contemporary Metal-on-Metal Total Hip Arthroplasty. Journal of Bone &amp; Joint Surgery (American Volume), 88, 1183-1191.</mixed-citation></ref><ref id="scirp.54932-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Catelas, I., Bobyn, J.D., Medley, J.B., Krygier, J.J., Zukor, D.J. and Huk, O.L. (2003) Size, Shape, and Composition of Wear Particles from Metal-Metal Hip Simulator Testing: Effects of Alloy and Number of Loading Cycles. Journal of Biomedical Materials Research, 67A, 312-327. http://dx.doi.org/10.1002/jbm.a.10088</mixed-citation></ref><ref id="scirp.54932-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Ponti, J., Sabbioni, E., Munaro, B., Broggi, F., Marmorato, P., Franchini, F., Colognato, R. and Rossi, F. (2009) Geno- toxicity and Morphological Transformation Induced by Cobalt Nanoparticles and Cobalt Chloride: An in Vitro Study in Balt/3T3 Mouse Fibroblasts. Mutagenesis, 24, 439-445.</mixed-citation></ref><ref id="scirp.54932-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Manova, D., Mandl, S. and Rauschenbach, B. (2001) Heat Balance during Plasma Immersion Ion Implantation. Plasma Sources Science and Technology, 10, 423-429.</mixed-citation></ref><ref id="scirp.54932-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Mandl, S. (2009) Increased Biocompatibility and Bioactivity after Energetic PVD Surface Treatments. Materials, 2, 1341-1387. http://dx.doi.org/10.3390/ma2031341</mixed-citation></ref><ref id="scirp.54932-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Tian, X., Gong, C., Yang, S., Luo, Z., Fu, R.K.Y. and Chu, P.K. (2006) Oxygen Plasma Ion Implantation of Biomedical Titanium Alloy. IEEE Transactions on Plasma Science, 34, 1235-1240.http://dx.doi.org/10.1109/TPS.2006.879002</mixed-citation></ref><ref id="scirp.54932-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Liu, X., Chu, P.K. and Ding, C. (2004) Surface Modification of Biomaterials Using Plasma Immersion Ion Implantation and Deposition. Materials Science and Engineering: R, 47, 49-121. http://dx.doi.org/10.1016/j.mser.2004.11.001</mixed-citation></ref><ref id="scirp.54932-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Mediero, A., Frenkel, S.R., Wilder, T., He, W., Mazumder, A. and Cronstein, B.N. (2012) Adenosine A2A Receptor Activation Prevents Wear Particle-Induced Osteolysis. Science Translational Medicine, 4, 168-177.http://dx.doi.org/10.1126/scitranslmed.3003393</mixed-citation></ref><ref id="scirp.54932-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Kim, K.J., Kobayashi, Y. and Itoh, T. (1998) Osteolysis Model with Continuous Infusion of Polyethylene Particles. Clinical Orthopaedics and Related Research, 352, 46-52. http://dx.doi.org/10.1097/00003086-199807000-00007</mixed-citation></ref><ref id="scirp.54932-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Oberdorster, G., Oberdorster, E. and Oberdorster, J. (2005) Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles. Environmental Health Perspectives, 113, 823-839. http://dx.doi.org/10.1289/ehp.7339</mixed-citation></ref><ref id="scirp.54932-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Pereira, M.C., Pereira, M.L. and Sousa, J.P. (1999) Histological Effects of Iron Accumulation on Mice Liver and Spleen after Administration of a Metallic Solution. Biomaterials, 20, 2193-2198.http://dx.doi.org/10.1016/S0142-9612(99)00124-6</mixed-citation></ref><ref id="scirp.54932-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Wolner, C., Nauer, G.E., Trummer, J., Putz, V. and Tschegg, S. (2006) Possible Reasons for the Unexpected Bad Biocompatibility of Metal-on-Metal Hip Implants. Materials Science and Engineering: C, 26, 34-40.http://dx.doi.org/10.1016/j.msec.2005.05.004</mixed-citation></ref><ref id="scirp.54932-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Sabokbar, A., Pandey, R., Quinn, J.M. and Athanasou, N.A. (1998) Osteoclastic Differentiation by Mononuclear Pha- gocytes Containing Biomaterial Particles. Archives of Orthopaedic and Trauma Surgery, 117, 136-140.http://dx.doi.org/10.1007/s004020050213</mixed-citation></ref><ref id="scirp.54932-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Gallo, J., Raska, M., Mrazek, F. and Petrek, M. (2008) Bone Remodeling, Particle Disease and Individual Susceptibility to Periprosthetic Osteolysis. Physiological Research, 57, 339-349.</mixed-citation></ref><ref id="scirp.54932-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Merkel, K.D., Erdmann, J.M., McHugh, K.P., Abu-Amer, Y., Ross, F.P. and Teitelbaum, S.L. (1999) Tumor Necrosis Factor Alpha Mediates Implant Osteolysis. American Journal of Pathology, 154, 203-210.http://dx.doi.org/10.1016/S0002-9440(10)65266-2</mixed-citation></ref><ref id="scirp.54932-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Wedemeyer, C., Xu, J., Neuerburg, C., Landgraeber, S., Malayar, N.M., von Knoch, F., Gosheger, G., von Knoch, M., Loer, F. and Saxler, G. (2007) Particle-Induced Osteolysis in Three-Dimensional Micro-Computed Tomography. Calcified Tissue International, 81, 394-402. http://dx.doi.org/10.1007/s00223-007-9077-2</mixed-citation></ref><ref id="scirp.54932-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Patntirapong, S., Habibovic, P. and Hauschka, P.V. (2009) Effects of Soluble Cobalt and Cobalt Incorporated into Calcium Phosphate Layers on Osteoclast Differentiation and Activation. Biomaterials, 30, 548-555.http://dx.doi.org/10.1016/j.biomaterials.2008.09.062</mixed-citation></ref><ref id="scirp.54932-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Peters, K., Schmidt, H., Unger, R.E., Kamp, G., Prols, F., Berger, B.J. and Kirkpatrick, C.J. (2005) Paradoxical Effects of Hypoxia-Mimicking Divalent Cobalt Ions in Human Endothelial Cells in Vitro. Molecular and Cellular Biochemistry, 270, 157-166.</mixed-citation></ref><ref id="scirp.54932-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">De Smet, K., De Haan, R., Calistri, A., Campbell, P.A., Ebramzadeh, E., Pattyn, C. and Gill, H.S. (2008) Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing. Journal of Bone &amp; Joint Surgery (American Volume), 90, 202-208. http://dx.doi.org/10.2106/JBJS.H.00672</mixed-citation></ref><ref id="scirp.54932-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Barry, M. (2010) New York Times.</mixed-citation></ref><ref id="scirp.54932-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Hart, A.J., Sabah, S.A., Bandi, A.S., Maggiore, P., Tarassoli, P., Sampson, B. and Skinner, J.A. (2011) Sensitivity and Specificity of Blood Cobalt and Chromium Metal Ions for Predicting Failure of Metal-on-Metal Hip Replacement. The Journal of Bone &amp; Joint Surgery (British Volume), 93, 1308-1313. http://dx.doi.org/10.1302/0301-620X.93B10.26249</mixed-citation></ref><ref id="scirp.54932-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">Tipper, J., Ingham, E., Jin, Z. and Fisher, J. (2005) The Science of Metal-on-Metal Articulation. Current Orthopaedics, 19, 280-287. http://dx.doi.org/10.1016/j.cuor.2005.08.002</mixed-citation></ref><ref id="scirp.54932-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">McMinn, D., Daniel, J., Ziaee, H. and Pradhan, C. (2011) Indications and Results of Hip Resurfacing. International Orthopaedics, 35, 231-237. http://dx.doi.org/10.1007/s00264-010-1148-8</mixed-citation></ref><ref id="scirp.54932-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Cawley, J., Metcalf, J.E.P., Jones, A.H., Bandb, T.J. and Skupien, D.S. (2003) A Tribological Study of Cobalt Chromium Molybdenum Alloys Used in Metal-on-Metal Resurfacing Hip Arthroplasty. Wear, 255, 999-1006.http://dx.doi.org/10.1016/S0043-1648(03)00046-2</mixed-citation></ref><ref id="scirp.54932-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Yan, Y., Neville, A., Dowson, D., Williams, S. and Fisher, J. (2008) Tribo-Corrosion Analysis of Wear and Metal Ion Release Interactions from Metal-on-Metal and Ceramic-on-Metal Contacts for the Application in Artificial Hip Prostheses. Proceedings of the Institution of Mechanical Engineers Part J-Journal of Engineering Tribology, 222, 483-492.http://dx.doi.org/10.1243/13506501JET366</mixed-citation></ref><ref id="scirp.54932-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Davis, J.R. (2003) Handbook of Materials for Medical Devices. ASM International.</mixed-citation></ref><ref id="scirp.54932-ref30"><label>30</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Karas</surname><given-names> S. </given-names></name>,<etal>et al</etal>. (<year>2012</year>)<article-title>Outcomes of Birmingham Hip Resurfacing: A Systematic Review</article-title><source> Asian Journal of Sports Medicine</source><volume> 3</volume>,<fpage> 1</fpage>-<lpage>7</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.54932-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Tennent, T.D. and Goddard, N.J. (2000) Current Attitudes to Total Hip Replacement in the Younger Patient: Results of a National Survey. Annals of The Royal College of Surgeons of England, 82, 33-38. https://www.researchgate.net/publication/12614461</mixed-citation></ref><ref id="scirp.54932-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Burns, A.W. and Bourne, R.B. (2006) Economics of Revision Total Hip Arthroplasty. Current Orthopaedics, 20, 203- 207. http://dx.doi.org/10.1016/j.cuor.2006.02.007</mixed-citation></ref><ref id="scirp.54932-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">OECD (2011) Health at a Glance 2011. Report, OECD Publishing.</mixed-citation></ref><ref id="scirp.54932-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Holzwarth, U. and Cotogno, G. (2012) JRC Scientific and Policy Reports. Publications Office of the European Union, European Commission, Luxembourg.</mixed-citation></ref></ref-list></back></article>