<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJU</journal-id><journal-title-group><journal-title>Open Journal of Urology</journal-title></journal-title-group><issn pub-type="epub">2160-5440</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/oju.2015.51001</article-id><article-id pub-id-type="publisher-id">OJU-52946</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  First Intraluminal Temperature Measurement during Ho:YAG-Laser Exposure at an &lt;i&gt;In-Vitro&lt;/i&gt; URS
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>elix</surname><given-names>Nguyen</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Karl-Dietrich</surname><given-names>Sievert</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jens</surname><given-names>Cordes</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Clinic of Urology, University Medical Center Schleswig-Holstein, Lübeck, Germany</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>Jens.Cordes@uk-sh.de(JC)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>06</day><month>01</month><year>2015</year></pub-date><volume>05</volume><issue>01</issue><fpage>1</fpage><lpage>5</lpage><history><date date-type="received"><day>2</day>	<month>November</month>	<year>2014</year></date><date date-type="rev-recd"><day>5</day>	<month>December</month>	<year>2014</year>	</date><date date-type="accepted"><day>15</day>	<month>December</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Introduction: The laser is a high energy instrument which can melt metals like nitinol. So it is very important to know under which conditions it is dangerous to perform an endourologic lithotripsy. We measure the temperature increase during laser exposure in an underwater 
  <em>in-vitro</em> ureter model. For comparison, temperatures with and without irrigation and with different distances from the laser fiber to the thermometer are measured. Materials and Methods: We used the Ho:YAG-laser (Vera Pulse
  <sup>TM</sup>, Coherent) with a 365 μm laser fiber. The settings of the laser were 0.6 J with a frequency of 5 Hz which is the minimum setting for that type of laser. The experimental setup was closely aligned with the clinical situation. A metal container was filled with 0.9% sodium chloride (NaCl) solution (Temp. 36.8&#176;) and a catheter with an inner diameter of 4 mm was attached to the rim of the container. The tip of the thermometer was attached inside the catheter through a waterproof hole. The laser fiber was guided by means of a rigid URS video device (11.5 F). We had four different settings during the measurement: 1) Distance of 0.5 cm between the laser and the thermometer; without irrigation, 2) Distance of 0.5 cm between the laser and the thermometer; with irrigation, 3) Distance of 1 cm between the laser and the thermometer; without irrigation, 4) Distance of 1 cm between the laser and the thermometer; with irrigation. Results: The maximum overall temperature was recorded in the 1) and 3) setting, both featuring no irrigation. The maximum temperature was ~50&#176;C in both settings, with the 1) setting reaching the maximum temperature after 50 seconds and hence approximately twice as fast as the 3) setting. During measurements with a NaCl solution flow we couldn’t detect any noticeable increase in temperature, neither at short nor at long distance between the laser fiber and the thermometer. Conclusion: There is a relevant heating in the ureter beside an endourologic lithotripsy. In our model we could reproduce a maximum heating until ~50&#176;C without irrigation and no heating with irrigation. Without irrigation there is a relevant bubble formation which should be an indicator for the surgeon to stop lithotripsy due to a temperature increase which could harm surrounding tissue.
 
</p></abstract><kwd-group><kwd>YAG-Laser</kwd><kwd> Exposure</kwd><kwd> Intraluminal</kwd><kwd> Irrigation</kwd><kwd> Laser Fiber</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The Ho:YAG-Laser is named as the gold standard lithotripsy modality for endoscopic lithotripsy [<xref ref-type="bibr" rid="scirp.52946-ref1">1</xref>] . In a global study of the endourological society with 11,885 patients, 49% (5820) of the physicians used the laser as a frag- mentation device beside the ureteroscopy [<xref ref-type="bibr" rid="scirp.52946-ref2">2</xref>] .</p><p>Acute complication like a perforation of the ureter by the laser is mainly caused by the photonic and acoustic energy the laser emits. The Ho:YAG-Laser is categorized as a potentially dangerous lithotripsy device for perforation [<xref ref-type="bibr" rid="scirp.52946-ref3">3</xref>] . Long time complications like ureteral strictures seem to be directed by thermal and mechanical injury. So it is important to know the temperature profiles in the ureter with different conditions. The laser is a high energy instrument which can melt a metal like nitinol [<xref ref-type="bibr" rid="scirp.52946-ref4">4</xref>] . So it is very important to know under which con- ditions it is dangerous to perform an endourologic lithotripsy.</p><p>We measure how the temperature increases during laser exposure in an underwater in-vitro ureter model. For comparison we measure temperatures with and without irrigation and with different distances from the laser fi- ber to the thermometer.</p></sec><sec id="s2"><title>2. Material and Methods</title><p>We used the Ho:YAG-laser (Vera Pulse<sup>TM</sup>, Coherent) with a 365 &#181;m laser fiber. The setting of the laser was 0.6 J with a frequency of 5 Hz which is the minimum setting for that type of laser. The experimental setup was closely aligned with the clinical situation (<xref ref-type="fig" rid="fig1">Figure 1</xref>).</p><p>A metal container was filled with 0.9% sodium chloride (NaCl) solution (Temp. 36.8˚) and a catheter with an inner diameter of 4 mm was attached to the rim of the container. The tip of the thermometer was attached inside the catheter through a waterproof hole. The Laser Fiber was guided by means of a rigid URS video device (11.5 F) (<xref ref-type="fig" rid="fig2">Figure 2</xref>).</p><p>The above mentioned instruments were now inserted into the artificial ureter with a distance between the tip of the thermometer and the laser fiber of both 0.5 cm and 1 cm (<xref ref-type="fig" rid="fig3">Figure 3</xref>).</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> The schematic drawing of the experimental setup shows the URS device with the laser fiber and the intraluminal tip of the thermometer inside a catheter surrounded by NaCl solution</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-5000250x6.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Artificial ureter with the probe of the thermometer (green cable) and the tip of the semirigid renoscope with the attached laser fiber</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-5000250x7.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> View from inside the catheter through the renoscope. Both the tip of the thermometer and the laser fiber are visible</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-5000250x8.png"/></fig><p>During the measurements with irrigation, a NaCl solution was piped through the URS-device. The irrigation has the same height as it is commonly used in our theater. The irrigation fluid came out of our warming facility with 37˚C (<xref ref-type="fig" rid="fig4">Figure 4</xref>).</p><p>We had four different settings during the measurement.</p><p>1) Distance of 0.5 cm between laser and thermometer; without irrigation;</p><p>2) Distance of 0.5 cm between laser and thermometer; with irrigation;</p><p>3) Distance of 1 cm between laser and thermometer; without irrigation;</p><p>4) Distance of 1 cm between laser and thermometer; with irrigation.</p></sec><sec id="s3"><title>3. Results</title><p>The maximum overall temperature was recorded in the 1) and 3) setting, both featuring no irrigation. The maximum temperature was 50˚C in both settings, with the 1) setting reaching the maximum temperature after 50 seconds and hence approximately twice as fast as the 3) setting (<xref ref-type="fig" rid="fig5">Figure 5</xref>). During measurements with a NaCl</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Photo of the experimental setup with the bassin and the irrigation fluid</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-5000250x9.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Four different settings: Short means 0.5 cm and long means 1 cm</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/1-5000250x10.png"/></fig><p>solution flow we couldn’t detect any noticeable increase in temperature, neither at short nor at long distance between the laser fiber and the thermometer.</p><p>Without continuous flow as in setting 1) and 3) we saw steady bubble emergence. With continuous irrigation no bubbles were detected. The starting temperature was 35˚C in the 1), 34.6˚C in the 2), 37.0˚C in 3) and 34.1˚C in the 4) setting. The starting temperatures differ 2.9˚C at maximum.</p></sec><sec id="s4"><title>4. Discussion</title><p>This is the first intraluminal temperature measurement of an activated Ho:YAG-Laser beside an in vitro URS. Molina et al. [<xref ref-type="bibr" rid="scirp.52946-ref5">5</xref>] already measured the Temperature Profile of Laser Lithotripsy Activation with a thermal camera. They measured outside a ureter model and with an open ureter model with a thermal camera. They used a higher energy setting with 1 J/Pulse and 10 Hz. With our model we can reproduce the external measurement with irrigation of 37.4˚C and without irrigation of 49.5˚C. In the open model they had higher temperature levels at 49.7˚C with irrigation and 112.4˚C without irrigation. Maybe the distance of 0.5 cm to the thermometer is an explanation for this difference. Also the open ureter in our setting could be a reason.</p><p>Limitation of this in vitro study is the open ureter. In the normal clinical setting maximal irrigation is only possible when the upper tract of the ureter is not full (of NaCl solution, for example) or the operating surgeon uses an irrigation set. The artificial ureter is thicker than a normal ureter. The measurement only covers one setting for the energy-level and one laser fiber of 365 &#181;m. Important for the physician is the bubble-emergence right in front of the laser fiber. The surgeon should be aware that steady bubble appearance could indicate a temperature increase.</p></sec><sec id="s5"><title>5. Conclusion</title><p>There is a relevant heating in the ureter beside an endourologic lithotripsy. In our model we could reproduce a maximum heating until ~50˚C without irrigation and no heating with irrigation. Without irrigation there is a re- levant bubble formation which should be an indicator for a physician to stop lithotripsy. There should be more studies to evaluate the temperature profile.</p></sec><sec id="s6"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.52946-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Marks, A.J. and Teichman, J.M. (2007) Lasers in Clinical Urology: State of the Art and New Horizons. World Journal of Urology, 25, 227-233. http://dx.doi.org/10.1007/s00345-007-0163-x</mixed-citation></ref><ref id="scirp.52946-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Rosette, J., Denstedt, J., Geavlete, P., Keeley, F., Matsuda, T., Pearle, M., Preminger, G. and Traxer, O. (2014) The Clinical Research Office of the Endourological Society Ureteroscopy Global Study: Indications, Complications and Outcomes in 11,885 Patients. Journal of Endourology, 28, 131-139. http://dx.doi.org/10.1089/end.2013.0436</mixed-citation></ref><ref id="scirp.52946-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Piergiovanni, M., Desgrandchamps, F., Cochand-Priollet, B., et al. (1994) Ureteral and Bladder Lesions after Ballistic, Ultrasonic, Electrohydraulic, or Laser Lithotripsy. Journal of Endourology, 8, 293-299. 
http://dx.doi.org/10.1089/end.1994.8.293</mixed-citation></ref><ref id="scirp.52946-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Cordes, J., Lange, B., Jocham, D. and Kausch, I. (2011) Destruction of Stone Extraction Basket during an in Vitro Lithotripsy—A Comparison of Four Lithotripters. Journal of Endourology, 25, 1-4. 
http://dx.doi.org/10.1089/end.2011.0019</mixed-citation></ref><ref id="scirp.52946-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Molina, W.R., Silva, I.N., Donalisio da Silva, R., Gustafson, D., Sehrt, D. and Kim, F.J. (2014) Influence of Saline on Temperature Profile of Laser Lithotripsy Activation. Journal of Endourology, 26. (Epub Ahead of Print)</mixed-citation></ref></ref-list></back></article>