<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JST</journal-id><journal-title-group><journal-title>Journal of Sensor Technology</journal-title></journal-title-group><issn pub-type="epub">2161-122X</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jst.2014.43013</article-id><article-id pub-id-type="publisher-id">JST-49410</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Computer Science&amp;Communications</subject><subject> Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Human Physical Activity Measurement Method Based on Electrostatic Induction
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>oichi</surname><given-names>Kurita</given-names></name><xref ref-type="aff" rid="aff1"><sub>1</sub></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><label>1</label><addr-line>Department of Electronic Engineering and Computer Science, Faculty of Engineering, Kinki University, 
Higashi-Hiroshima, Japan</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>kurita@hiro.kindai.ac.jp</email></corresp></author-notes><pub-date pub-type="epub"><day>01</day><month>08</month><year>2014</year></pub-date><volume>04</volume><issue>03</issue><fpage>139</fpage><lpage>147</lpage><history><date date-type="received"><day>27</day>	<month>June</month>	<year>2014</year></date><date date-type="rev-recd"><day>25</day>	<month>July</month>	<year>2014</year>	</date><date date-type="accepted"><day>26</day>	<month>August</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  
    In this study, an effective noncontact and nonattached technique that is based on electrostatic induction current generated during walking motion is proposed for the detection and assessment of human physical activity. In addition, a theoretical model is proposed for the electrostatic induction current generated owing to variation in the electric potential of the human body. The proposed electrostatic induction current model is compared with the theoretical model, and the proposed model is shown to effectively explain the behavior of the electrostatic induction current waveform. The normal walking motions of daily living are recorded with a portable sensor located in a regular house. The obtained results show that detailed information of physical activity such as a gait cycle can be estimated using our proposed technique. Additionally, the walking signal was measured when the subject walked with the ankle and knee fastened to a splint with bandages to simulate a limp. Therefore, the proposed technique, which is based on the detection of signal generated during walking, can be successfully employed to assess human physical activity. 
  
 
</p></abstract><kwd-group><kwd>Human Walking</kwd><kwd> Electrostatic Induction</kwd><kwd> Human Physical Activity</kwd><kwd> Walking with a Limp</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Physical activity improves general health and well-being. The benefits of physical activity include prevention of cerebral accidents, cardiovascular disease, and some cancers. These benefits can also be enjoyed in old age, when the incidence of many diseases and disabilities increases. Researchers have made numerous attempts to develop methods for measuring physical activity because precise measurements of physical activity will enable the assessment of physical activity in the same way as a physical activity diary. Self-report measures are often used to estimate physical activity. However, they have some disadvantages such as the difficulty of estimating activity patterns throughout the day [<xref ref-type="bibr" rid="scirp.49410-ref1">1</xref>] and fluctuations in health status [<xref ref-type="bibr" rid="scirp.49410-ref2">2</xref>] . Therefore, objective human physical activity estimation methods are attracting increasing attention because they can overcome the limitations of self-report measures. Particularly, measurement of the acceleration of the body of a subject provides information about the amount, frequency, and duration of physical activity [<xref ref-type="bibr" rid="scirp.49410-ref3">3</xref>] . An objective physical activity measurement method such as accelerometry can also assess free-living activity. Objective physical activity measurements [<xref ref-type="bibr" rid="scirp.49410-ref4">4</xref>] prove that participation in non-exercise physical activity such as housework and climbing stairs reduces mortality risk.</p><p>In particular, walking for exercise is especially effective for long-term weight loss [<xref ref-type="bibr" rid="scirp.49410-ref5">5</xref>] , increasing HDL (high-density lipoprotein cholesterol) [<xref ref-type="bibr" rid="scirp.49410-ref6">6</xref>] , reducing blood pressure [<xref ref-type="bibr" rid="scirp.49410-ref7">7</xref>] , and lowering the risk of heart disease and cancer initiation. In the last decade, gait analysis has attracted much attention from computer vision researchers motivated by its wide application potential. In vision-based human motion detection systems, motion features are typically extracted from image sequences. Subsequently, the magnitudes of the features are compared as an identification process. However, in conventional human motion detection methods, experimental conditions such as the distance between the subject and camera and the angle and pixel density of the camera significantly influence the recognition rate of the system. Moreover, the primary drawback of these methods is that they cannot detect anything in the dead zone of the camera. Furthermore, many image-processing systems require complex logic to compensate for the disturbances caused by the motion of nonhuman objects.</p><p>Alternatively, body-mounted accelerometers [<xref ref-type="bibr" rid="scirp.49410-ref8">8</xref>] -[<xref ref-type="bibr" rid="scirp.49410-ref10">10</xref>] are extensively used for monitoring human motion because these systems are inexpensive when compared with an optoelectronic motion capture system. Another advantage of body-mounted accelerometers is that the system can be used in an indoor/outdoor space. Additionally, numerous methods have been presented to measure human activity using different techniques such as an ultrasonic motion analysis system to temporally and spatially measure the amount of human activity, an electromagnetic 3-D orientation estimation system that uses the Earth’s magnetic field, and a wearable ultrasonic motion analysis system. However, in these measurement systems, some type of sensor or marker that remains in contact with the subject must be used. Therefore, these methods have not been applied in noncontact detection of human activity measurement.</p><p>In this paper, we present a new objective human physical activity estimation method that does not use a camera or an accelerometer. We have developed an effective noncontact and nonattached technique for the detection of human walking motion using human-generated body charge. This technique involves the detection of an electrostatic induction current of the order of approximately sub-picoamperes flowing through an electrode placed at a distance of 3 m from a subject. The absolute value of electrostatic induction current depends on the type of footwear of the subject and floor material. However, we confirm that this technique has sufficient sensitivity to detect the electrostatic induction current generated during the walking motion in daily life. This technique effectively explains the behavior of the waveform of the electrostatic induction current flowing through a given measurement electrode via a capacitance model for the human body. Moreover, a study wherein the leg of a normal subject was attached to a splint using bandages was conducted to determine the change in the subject’s gait. The waveform of the electrostatic induction current generated owing to the motion of walking was observed to vary under different fastening conditions (Cases 1-3 described in the experimental method section). Experimental results show that the cadence patterns of the induced current vary with the fastening conditions. The proposed technique enables the detection of even subtle differences in walking motion thus proving that the quality of walking motion can be estimated using the proposed technique.</p><p>This paper is organized as follows. Section 2 explains the principle of the detection for the electrostatic induction current generated by walking motion under noncontact and nonattached conditions. The experimental method is described in Section 3. The experimental results and discussion are presented in Section 4. The final section presents the conclusion of this paper.</p></sec><sec id="s2"><title>2. Principle</title><p>Let us consider the example of a walking motion to explain the principle of the abovementioned measurement technique. The human body is electrically charged during walking [<xref ref-type="bibr" rid="scirp.49410-ref11">11</xref>] -[<xref ref-type="bibr" rid="scirp.49410-ref14">14</xref>] . In the case when a subject is standing or walking, we assume that two highly resistive layers exist between the feet of the subject and the floor, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. One layer is the sole of the footwear of the subject, and the other is the floor surface.</p><fig-group id="fig1"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Schematic of interaction between the human body and the floor surface layer during walking motion.</title></caption><fig id ="fig1_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x5.png"/></fig></fig-group><p>The reciprocal of capacitance of the feet relative to the ground <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x6.png" xlink:type="simple"/></inline-formula> may be calculated as the sum of the reciprocal of capacitance of the sole <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x7.png" xlink:type="simple"/></inline-formula> and the reciprocal of capacitance of the floor surface<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x8.png" xlink:type="simple"/></inline-formula>, as shown below:</p><disp-formula id="scirp.49410-formula160"><label>. (1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-4200124x9.png"  xlink:type="simple"/></disp-formula><p>The electric capacitance between the sole and floor <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x10.png" xlink:type="simple"/></inline-formula> can be expressed as follows:</p><disp-formula id="scirp.49410-formula161"><label>. (2)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-4200124x11.png"  xlink:type="simple"/></disp-formula><p>where S is the area of the sole, and S<sub>c</sub> is the contact area between the sole and floor. Further, <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x12.png" xlink:type="simple"/></inline-formula>is the delamination area of the sole against the floor, and x and x<sub>0</sub> denote the distances between the sole and the earth and the floor surface and the earth, respectively. In addition, ε<sub>a</sub> is the permittivity of the air gap between the sole and the floor, and ε<sub>f</sub> is the averaged permittivity of the floor materials between the floor surface and the earth. Further, S must be replaced with an area of the sole projected onto the floor. However, the projected area is exactly similar to S in the case of normal waking motion. Therefore, S is assumed to be a time-independent constant value in place of the projected area in the above equation.</p><p>On the other hand, the electric capacitance of the human body (C<sub>B</sub>) during walking motion can be expressed as follows:</p><disp-formula id="scirp.49410-formula162"><label>. (3)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-4200124x13.png"  xlink:type="simple"/></disp-formula><p>Therefore, the electric potential of the human body <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x14.png" xlink:type="simple"/></inline-formula> during the motion of walking can be expressed as follows:</p><disp-formula id="scirp.49410-formula163"><label>. (4)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-4200124x15.png"  xlink:type="simple"/></disp-formula><p>where Q<sub>B</sub> is the instantaneous charge of the human body during walking motion. The induced charge <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x16.png" xlink:type="simple"/></inline-formula> of a measurement electrode placed at a certain distance from the subject can be expressed as</p><disp-formula id="scirp.49410-formula164"><label>. (5)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-4200124x17.png"  xlink:type="simple"/></disp-formula><p>where C is the capacitance between the human body and the measurement electrode in the wireless portable sensor, and V is the potential of the measurement electrode. From the above two equations, the induced current flowing through the measurement electrode <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x18.png" xlink:type="simple"/></inline-formula> can be expressed as follows:</p><disp-formula id="scirp.49410-formula165"><label>(6)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/3-4200124x19.png"  xlink:type="simple"/></disp-formula><p>We assume that the human body is a good conductor. The second term on the right-hand side of Equation (6) represents the current induced by the motion of the foot before it is lifted off the floor. When the toe of the right foot is lifted off the floor, S<sub>c</sub> decreases. Therefore, I increases as predicted by the second term on the right-hand side of Equation (6). On the other hand, the first term on the right-hand side of Equation (6) represents the current induced by the motion of the foot before it is lifted off the floor. The first term is approximately proportional to the speed of the foot in a direction perpendicular to the floor. However, the first term of Equation (6) has a small effect on I because ε<sub>a</sub> is less than ε<sub>f</sub>. Additionally, the speed of motion in a direction perpendicular to the floor is less in the case of typical walking motion. Therefore, the influence of the first term of Equation (6) on signal intensity is small when compared with that of the second term of Equation (6) in the case of normal walking motion. Therefore, in the case of walking motion near the measurement electrode, the electrostatic induction current generated when the subject’s foot is in contact with and off the floor can be measured under perfect noncontact and nonattached conditions.</p></sec><sec id="s3"><title>3. Experimental Method</title><p>A schematic of the measurement system for the electrostatic induction current generated owing to the variation in the electric potential of a subject’s body is shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The electrostatic induction current flowing through an electrode in the wireless portable sensor placed less than 5 m from the body of the subject is converted into voltage with an <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x20.png" xlink:type="simple"/></inline-formula> converter having a conversion ratio of 20 V/pA and comprising an operational amplifier (op-amp). The <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x21.png" xlink:type="simple"/></inline-formula> converter consists of two low input current op-amps, a feedback capacitance <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x22.png" xlink:type="simple"/></inline-formula> of approximately 0.2 pF, and a feedback resistance <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x20.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x21.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x22.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x23.png" xlink:type="simple"/></inline-formula> of 10 TΩ, as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. The stray capacitance is formed by winding a tinned copper wire on the feedback resistance because the required electric capacitance is less than the minimum value of a marketed capacitor. The selected low-noise op-amp has an input offset voltage of 40 μV and an input offset current of 1 pA. The feedback resistor connected to the op-amp is a hermetically sealed large value resistor that can prevent stray current due to humidity. For measurements with high input resistance, a conventional guarding method is absolutely necessary for shielding op-amps; this prevents stray currents from entering sensitive nodes. Sensitive nodes are surrounded by a guard conductor that is maintained at the same electric potential as the sensitive node. In addition, induction currents generated by commercial power sources manifest in the form of noise. Therefore, a filtering system with a cutoff frequency</p><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Schematic of system for detecting motion in a house using portable sensor</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x24.png"/></fig><fig id="fig3"  position="float"><label><xref ref-type="fig" rid="fig3">Figure 3</xref></label><caption><title> Schematic circuit diagram of I-V converter</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x25.png"/></fig><p>of 20 Hz and a 60-Hz notch filter are used. This measurement system is unaffected by noise from other electronic devices such as mobile phones and microwave ovens. The analog signals are subsequently converted into digital signals with a 16-bit analog-to-digital (A/D) converter.</p><p>The XBee protocol is used for wireless data transmission from the portable motion detection system to a personal computer. Data were acquired at a sampling frequency of 100 Hz, which is safe because the actual data transmission rate on XBee networks is as low as approximately 10 kbps. This sampling frequency is sufficient for detecting contact events. The measurement electrode is a square with a side of 2 cm. The wireless portable sensor was placed in the ceiling of an ordinary house with wooden floors, as shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>. The subjects were asked to wear slippers and walk normally on the wooden floor. The subjects (A, B, and C) were 3 healthy men aged between 19 and 20 years. The subjects were asked to walk in a cycle of approximately 100 steps per minute to maintain the same cycle of walking. Moreover, the signal produced when the subject walked with the ankle and knee fastened to a splint with bandages to simulate a limp was measured. Subject A was asked to perform different tasks such as walk normally (Case 1), walk with the left ankle fastened to a splint using bandages (Case 2), and walk with the left ankle and left knee fastened to a splint with bandages (Case 3).</p></sec><sec id="s4"><title>4. Results and Discussion</title><sec id="s4_1"><title>4.1. Walking Signal</title><p><xref ref-type="fig" rid="fig4">Figure 4</xref> shows the typical waveform of the current generated during human walking motion. Cadence components are observed in the resulting waveform for each case. These components indicate the presence of a gait cycle in the walking motion. This gait cycle consists of a combination of alternating swing and stance phases for the left and right feet. The waveform contains cadence components for both feet during bipedal walking indicating that the toe of the left foot is lifted off the floor while the heel of the right foot simultaneously comes in contact with the floor. When the toe of the right foot is lifted off the floor, S decreases, and the distance between the right foot and floor <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x26.png" xlink:type="simple"/></inline-formula> increases steadily. As a result of the walking motion, I increases, as predicted by the first term on the right-hand side of Equation (6). In rapid succession, I decreases, as predicted by the second term on the right-hand side of Equation (6). Furthermore, during the second half of the swing phase, a rapid decrease in x induces a reduction in I, as predicted by the first term on the right-hand side of Equation (6). In rapid succession, I decreases with an increase in S owing to heel contact, as predicted by the second term on the right-hand side of Equation (6). Therefore, Equation (6) effectively explains the behavior of the waveform of the electrostatic induction current flowing through the measurement electrode.</p><p>The portable sensor was placed in ceiling of an ordinary house with a wooden floor, as shown in <xref ref-type="fig" rid="fig2">Figure 2</xref>. The subjects were asked to wear slippers and walk normally on a wooden floor. The waveforms of the electrostatic induction currents generated during walking motion are shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>. The variation in the intensity of the signal obtained by the portable sensor indicates that the subject is moving closer to the portable sensor and then moving away from it. Therefore, detailed information about physical activity can be estimated using our proposed technique. We have developed an effective noncontact technique for the detection of human physical activity using human-generated body charge.</p><p>The absolute value of I depends on the type of footwear and floor material. However, this technique has sufficient sensitivity to detect the electrostatic induction current generated during walking motion in daily life. This</p><fig id="fig4"  position="float"><label><xref ref-type="fig" rid="fig4">Figure 4</xref></label><caption><title> Typical waveform of current generated owing to human walking motion</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x27.png"/></fig><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig5">Figure 5</xref></label><caption><title> Waveforms of current generated owing to human walking motion for 40 s</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x28.png"/></fig><p>technique effectively explains the behavior of the waveform of the electrostatic induction current flowing through a given measurement electrode in a wireless portable sensor via a capacitance model for the human body.</p></sec><sec id="s4_2"><title>4.2. Physically Disabled Walking</title><p>Experimental tests of physically disabled walking motion were conducted because a significant variation occurs in the time derivative of the contact area between the sole and the floor<inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x29.png" xlink:type="simple"/></inline-formula>, which is represented by the second term on the right-hand side of Equation (6), in such motion. <xref ref-type="fig" rid="fig6">Figure 6</xref> shows the typical waveforms of the electrostatic induction current generated in each case. In this figure, the waveform of Case 1 is obtained under normal walking condition. As can be clearly seen, peaks are induced by both feet in a period of the walking cycle. The peaks R and L represent the waveform induced by the right and left feet, respectively. The obtained waveforms are similar for each foot. The waveform of Case 2 was obtained under the walking condition where the left ankle is fastened to a splint using bandages. In Case 2, the waveforms of the left leg are slightly different from those of the right leg when compared with the normal walking motion (Case 1). Moreover, dual peaks are observed in the waveform of the right foot. Fastening of the left ankle of the subject influences not only the motion of the left foot but also that of the right foot. The waveform of Case 3 was obtained under walking condition where the left ankle and left knee are fastened to a splint with bandages. The waveforms of the left foot are significantly different from those of the right foot in Case 1 and Case 2. The intensity of peaks <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x29.png" xlink:type="simple"/></inline-formula><inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x30.png" xlink:type="simple"/></inline-formula> is reduced when compared with Case 1 and Case 2. Moreover, a broadening of the peaks is observed for the right foot. Therefore, the cadence patterns of the induced current vary with fastening conditions.</p><p><xref ref-type="fig" rid="fig7">Figure 7</xref> shows the FFT-analyzed spectral data of the electrostatic induction current waveform generated in each walking case. A comparison of the spectral data shows that the gait cycle is almost identical in all the cases. Each FFT spectrum shows a peak (P<sub>g</sub>) at approximately 1.71 Hz, which is attributed to the presence of the gait cycle. In Case 1, as can be clearly seen, one primary and some harmonic peaks (P<sub>h</sub> in <xref ref-type="fig" rid="fig4">Figure 4</xref>) are induced by the gait cycle. In Case 2, peaks are not observed at higher harmonic frequencies. Furthermore, additional peaks</p><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig6">Figure 6</xref></label><caption><title> Waveforms of current generated owing to normal walking motion (Case 1 shown in upper panel), walking with the left ankle fastened to a splint using bandages (Case 2 shown in middle panel), and walking with the left ankle and left knee fastened to a splint using bandages (Case 3 shown in lower panel)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x31.png"/></fig><fig id="fig7"  position="float"><label><xref ref-type="fig" rid="fig7">Figure 7</xref></label><caption><title> Typical FFT-analyzed spectral data of electrostatic induction current for human walking motion of subject A under normal walking motion (Case 1 shown in upper panel), walking motion with the left ankle fastened to a splint using bandages (Case 2 shown in middle panel), and walking motion with the left ankle and left knee fastened to a splint using bandages (Case 3 shown in lower panel)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-4200124x32.png"/></fig><p>(P<sub>1</sub> and P<sub>2</sub>) are observed in this spectrum. Similar to Case 2, there are no peaks for higher harmonic frequencies in Case 3. The intensity of peaks of higher harmonic frequencies decreases with the degree of fastening indicating that the gait cycle is affected by the fastening of the other foot. The degree of fastening is directly reflected in the electrostatic induction current generated owing to the walking motion.</p><p>We can say with fair certainty that the variations in the spectra are due to a difference in the time derivative of the contact area between the sole and the floor <inline-formula><inline-graphic xlink:href="http://html.scirp.org/file/3-4200124x33.png" xlink:type="simple"/></inline-formula> at which the feet are lifted off the floor in the stance phase. Therefore, the proposed technique enables the detection and quantitative assessment of even subtle differences in walking motion.</p></sec></sec><sec id="s5"><title>5. Conclusion</title><p>This paper presented the development of an effective noncontact and nonattached technique for the detection of human physical activity using human-generated body charge. This technique involved the detection of an electrostatic induction current of the order of approximately sub-picoamperes flowing through an electrode. A theoretical model was proposed for the electrostatic induction current generated during the walking motion. The proposed model was compared with the theoretical model and was shown to effectively explain the behavior of the waveform of the electrostatic induction current flowing through the measurement electrode. The normal walking motions of daily living were detected with a portable sensor located in a regular house. The obtained results showed that detailed information of physical activity such as a gait cycle could be estimated using our proposed technique. The electrostatic induction current was also measured when the subject walked with the left ankle and left knee fastened to a splint with bandages to simulate a limp. The obtained results show that the degree of fastening of the foot is directly reflected in the generated electrostatic induction current. This technique can detect even subtle differences in the walking style. Therefore, the proposed technique based on the detection of the signal generated owing to walking motion can be successfully employed to not only estimate the gait cycle and number of steps but also study the quality of walking motion.</p></sec><sec id="s6"><title>Acknowledgements</title><p>This research was partially supported by the Grant-in-Aid for Scientific Research (C), 26350056, 2014.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.49410-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Davis, M.G. and Fox, K.R. (2007) Physical Activity Patterns Assessed by Accelerometry in Older People. European Journal of Applied Physiology, 100, 581-589. http://dx.doi.org/10.1007/s00421-006-0320-8</mixed-citation></ref><ref id="scirp.49410-ref2"><label>2</label><mixed-citation publication-type="journal" xlink:type="simple"><name name-style="western"><surname>Rikli</surname><given-names> R.E. </given-names></name>,<etal>et al</etal>. (<year>2000</year>)<article-title>Reliability, Validity, and Methodological Issues in Assessing Physical Activity in Older Adults</article-title><source> Research Quarterly for Exercise Sport</source><volume> 71</volume>,<fpage> S89</fpage>-<lpage>S96</lpage>.<pub-id pub-id-type="doi"></pub-id></mixed-citation></ref><ref id="scirp.49410-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Plasqui, G. and Westerterp, K.R. (2007) Physical Activity Assessment with Accelerometers: An Evaluation against Doubly Labeled Water. Obesity, 15, 2371-2379. http://dx.doi.org/10.1038/oby.2007.281</mixed-citation></ref><ref id="scirp.49410-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Pate, R.R., et al. (1995) Physical Activity and Public Health. A Recommendation from the Centers for Disease Control and Prevention and the American College of Sports Medicine. Journal of the American Medical Association, 273, 402-407. http://dx.doi.org/10.1001/jama.1995.03520290054029</mixed-citation></ref><ref id="scirp.49410-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Ballor, D.L. and Keesev, R.E. (1991) A Meta-Analysis of the Factors Affecting Exercise-Induced Changes in Body Mass, Fat Mass, and Fat-Free Mass in Males and Females. International Journal of Obesity, 5, 717-726.</mixed-citation></ref><ref id="scirp.49410-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Fogelholm, M. (2000) Effects of Walking Training on Weight Management after a Very Low Energy Diet in Premenopausal Obese Women: A Randomized Controlled Trial. Archives of Internal Medicine, 160, 2177-2184. 
http://dx.doi.org/10.1001/archinte.160.14.2177</mixed-citation></ref><ref id="scirp.49410-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Dunn, A.L. (1999) Comparison of Lifestyle and Structured Interventions to Increase Physical Activity and Cardiorespiratory Fitness: A Randomized Trial. Journal of the American Medical Association, 281, 327-334. 
http://dx.doi.org/10.1001/jama.281.4.327</mixed-citation></ref><ref id="scirp.49410-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Morris, J.R.W. (1973) Accelerometry—A Technique for the Measurement of Human Body Movements. Journal of Biomechanics, 6, 729-739. http://dx.doi.org/10.1016/0021-9290(73)90029-8</mixed-citation></ref><ref id="scirp.49410-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Williamson, R. and Andrews, B.J. (2001) Detecting Absolute Human Knee Angle and Angular Velocity Using Accelerometers and Rate Gyroscopes. Medical Biological Engineering Computing, 39, 1-9.  
http://dx.doi.org/10.1007/BF02345283</mixed-citation></ref><ref id="scirp.49410-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Mansfield, A. and Lyons, G.M. (2003) The Use of Accelerometry to Detect Heel Contact Events for Use as a Sensor in FES Assisted Walking. Medical Engineering Physics, 25, 879-885. http://dx.doi.org/10.1016/S1350-4533(03)00116-4</mixed-citation></ref><ref id="scirp.49410-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Amoruso, V., et al. (2000) An Improved Model of Man for ESD Application. Journal of Electrostatics, 49, 225-244. 
http://dx.doi.org/10.1016/S0304-3886(00)00020-6</mixed-citation></ref><ref id="scirp.49410-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Ohsawa, A. (2001) Electrostatic Characterization of Antistatic Floors Using an Equivalent Circuit Model. Journal of Electrostatics, 51-52, 625-631. http://dx.doi.org/10.1016/S0304-3886(01)00031-6</mixed-citation></ref><ref id="scirp.49410-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Ficker, T. (2006) Electrification of Human Body by Walking. Journal of Electrostatics, 64, 10-16. 
http://dx.doi.org/10.1016/j.elstat.2005.04.002</mixed-citation></ref><ref id="scirp.49410-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Kurita, K. (2009) New Estimation Method for the Electric Potential of the Human Body under Perfect Noncontact Conditions. IEEJ Transactions on Electrical and Electronic Engineering, 4, 309-311.  
http://dx.doi.org/10.1002/tee.20410</mixed-citation></ref></ref-list></back></article>