<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AJAC</journal-id><journal-title-group><journal-title>American Journal of Analytical Chemistry</journal-title></journal-title-group><issn pub-type="epub">2156-8251</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ajac.2014.59064</article-id><article-id pub-id-type="publisher-id">AJAC-47036</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Fluorescent-Dye Doped Thin-Film Sensors for the Detection of Alcohol Vapors
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>onathan</surname><given-names>K. Fong</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Royce</surname><given-names>N. Dansby-Sparks</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Adam</surname><given-names>C. Lamb</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Thomas</surname><given-names>W. Owen</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Mohammad</surname><given-names>Mushfiq</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Uma</surname><given-names>Sampathkumaran</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Kisholoy</surname><given-names>Goswami</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Scott</surname><given-names>L. Jensen</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Zi-Ling</surname><given-names>Xue</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Chemistry, University of Tennessee, Knoxville, USA</addr-line></aff><aff id="aff3"><addr-line>NASA John C. Stennis Space Center, Stennis Space Center, USA</addr-line></aff><aff id="aff2"><addr-line>InnoSense LLC, Torrance, USA</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>xue@ion.chem.utk.edu(ZX)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>20</day><month>06</month><year>2014</year></pub-date><volume>05</volume><issue>09</issue><fpage>566</fpage><lpage>580</lpage><history><date date-type="received"><day>17</day>	<month>April</month>	<year>2014</year></date><date date-type="rev-recd"><day>31</day>	<month>May</month>	<year>2014</year>	</date><date date-type="accepted"><day>14</day>	<month>June</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Fluorescence sensors based on a trifluoroacetophone compound doped in ethyl cellulose (EC) thin films have been developed for the detection of methanol, ethanol, and 2-propanol (isopropanol, PriOH) vapors. Thin-film sensors are prepared with 4-dibutylamino-4’-(trifluoroacetyl)stilbene (Chromoionophore IX or CIX) as the fluorescent dye and its solution in EC was spin-coated onto glass slides. The luminescence intensity of the dye (555 nm) is quenched when exposed to alcohol vapor. Tested in the range of ca. 0 - 1.5 &#215; 10&lt;sup&gt;4&lt;/sup&gt; ppm (wt) for MeOH and EtOH, and ca. 0 - 2.3 &#215; 10&lt;sup&gt;4&lt;/sup&gt; ppm for Pr&lt;sup&gt;i&lt;/sup&gt;OH, the sensors gave detection limits of 9, 13, 21 ppm and quantification limits of 32, 43, and 70 ppm, respectively. To enhance the sensitivity of the sensors, TiO&lt;sub&gt;2&lt;/sub&gt; particles have been added to the films to induce Mie scattering, which increases the incident light interaction with the sensing films. The sensors in this work have been designed to work in a multianalyte platform for the simultaneous detection of multiple gas analytes.
 
</p></abstract><kwd-group><kwd>Optical Thin Film Sensors</kwd><kwd> Chromoionophore IX Dye</kwd><kwd> Alcohol Vapor Detection</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Alcohol vapor detection is an area of intense interest. Since fossil fuels are not a renewable source of energy, the need for promising alternatives such as alcohol has steadily increased in demand. Fuels heavily blended with alcohol have shown promise in the automotive industry [<xref ref-type="bibr" rid="scirp.47036-ref1">1</xref>] . In addition, methanol has been actively studied in fuel cells [<xref ref-type="bibr" rid="scirp.47036-ref2">2</xref>] . The increasing use of methanol as a fuel may lead to the greater exposure of methanol vapors to the general public due to, e.g., unburned fuel in the form of exhaust or from evaporation during refueling [<xref ref-type="bibr" rid="scirp.47036-ref1">1</xref>] . Listed as one of air toxics by the US Environmental Protection Agency, methanol vapor can cause nausea, headaches, and even blindness [<xref ref-type="bibr" rid="scirp.47036-ref3">3</xref>] - [<xref ref-type="bibr" rid="scirp.47036-ref5">5</xref>] . In 2002, an experimental physicist developed Parkinson’s disease from the delayed toxic effect of long term exposure to methanol vapors without showing any signs of acute toxicity [<xref ref-type="bibr" rid="scirp.47036-ref6">6</xref>] . The permissible exposure limit to methanol is set at 200 mg・kg<sup>−1</sup> by the US Occupational Safety and Health Administration (OSHA) [<xref ref-type="bibr" rid="scirp.47036-ref5">5</xref>] .</p><p>Detection of ethanol vapor is also an area of particular interest because of the need for responsive and reversible sensors to detect alcohol in human breath. Ethanol has been increasingly used as a blend in gasoline as well [<xref ref-type="bibr" rid="scirp.47036-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.47036-ref8">8</xref>] . While it is renewable, bio-ethanol is known to be corrosive to stainless steel and other metals/alloys [<xref ref-type="bibr" rid="scirp.47036-ref8">8</xref>] , and gas tank corrosion has led to leaks that require detection. Since ethanol and gasoline have different physical and thermodynamic properties, engines in vehicles, especially flex fuel vehicles, need to be optimized for performance accordingly [<xref ref-type="bibr" rid="scirp.47036-ref9">9</xref>] . Ethanol has a lower vapor pressure than gasoline which could lead to potential cold start engine problems particularly in flex fuel vehicles [<xref ref-type="bibr" rid="scirp.47036-ref9">9</xref>] . These examples help to establish a critical need for ethanol detection.</p><p>A variety of commercial products used to detect ethanol vapors, specifically those used in breathalyzers for blood alcohol content (BAC), are based mainly on three different techniques: infrared (IR) spectroscopy, semiconductor metal oxides, and electrochemical fuel cells [<xref ref-type="bibr" rid="scirp.47036-ref10">10</xref>] - [<xref ref-type="bibr" rid="scirp.47036-ref12">12</xref>] . IR spectroscopy is based on characteristic vibrations of ethanol [<xref ref-type="bibr" rid="scirp.47036-ref13">13</xref>] . As discussed below, many compounds, however, interfere with its detection by IR. Semiconductor sensor technology often utilizes an oxide such as tin dioxide (SnO<sub>2</sub>). When exposed to ethanol in breath samples, ethanol is adsorbed on SnO<sub>2</sub>, changing its electrical resistance. The change is measured to give the ethanol concentration [<xref ref-type="bibr" rid="scirp.47036-ref13">13</xref>] . Vapors of other chemicals may be adsorbed on SnO<sub>2</sub>, leading to interferences. Fuel cell breathalyzers catalyze the oxidation of ethanol and measure the electrical voltage to determine the concentration of alcohol present [<xref ref-type="bibr" rid="scirp.47036-ref13">13</xref>] . Fuel cell breathalyzers are less susceptible to interferences. A recently patented breathanalyzer uses silica gel impregnated with a sulphochromic [Cr(VI) + H<sub>2</sub>SO<sub>4</sub>] solution [<xref ref-type="bibr" rid="scirp.47036-ref14">14</xref>] that may contain toxic chromate [<xref ref-type="bibr" rid="scirp.47036-ref15">15</xref>] . There has been ongoing and continued research in the field of alcohol detection such as miniature GC [<xref ref-type="bibr" rid="scirp.47036-ref16">16</xref>] and bioelectronic gas sensors (biosniffers) [<xref ref-type="bibr" rid="scirp.47036-ref17">17</xref>] to improve and advance alcohol analyzers based on other methods.</p><p>Highly sensitive detection of 2-propanol is needed by NASA (National Aeronautics and Space Administration) for a new rocket engine which is designed to be used at altitudes of approximately 30,480 m [<xref ref-type="bibr" rid="scirp.47036-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.47036-ref19">19</xref>] . To simulate these conditions, a vacuum must be produced by steam generated through the combustion of 2- propanol with liquid oxygen [<xref ref-type="bibr" rid="scirp.47036-ref18">18</xref>] [<xref ref-type="bibr" rid="scirp.47036-ref19">19</xref>] . Similarly to methanol, OSHA Permissible Exposure Limit for Pr<sup>i</sup>OH is 400 mg・kg<sup>−1</sup> TWA (Time-Weighted Average) [<xref ref-type="bibr" rid="scirp.47036-ref20">20</xref>] and prolonged exposure to 2-propanol vapor can cause irritation of the respiratory system and mucous membranes and, at higher concentrations, cause central nervous system depression [<xref ref-type="bibr" rid="scirp.47036-ref21">21</xref>] . It has also been reported that the ingestion of 2-propanol is also not uncommon among alcoholics as a substitute for conventional alcoholic drinks [<xref ref-type="bibr" rid="scirp.47036-ref22">22</xref>] . Fatalities have been reported due to the ingestion of 2-propanol and there have been some cases of routine DUI road-traffic investigations involving individuals admitting to drinking commercial products comprised of almost pure 2-propanol before the traffic incident [<xref ref-type="bibr" rid="scirp.47036-ref22">22</xref>] . Therefore, a need for a near real-time sensor for the remote detection of Pr<sup>i</sup>OH would be beneficial for 2-pro- panol vapor and rocket plume testing conditions.</p><p>In addition to commercial breathanalyzers, other techniques developed to sense alcohol vapor are largely based on the solvatochromatic effect (or their physical changes inside the sensor matrices). Stevens and Akins have developed a fluorescence sensor using the dye Coumarin 481 specifically for methanol vapor at 150 mg・kg<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.47036-ref23">23</xref>] . The sensor in that study displays fluorescence quenching upon exposure to methanol as a result of physical changes inside the sensor matrix. However, the fluorescence intensity is not fully recoverable possibly because of an irreversible morphological change in the film [<xref ref-type="bibr" rid="scirp.47036-ref23">23</xref>] . Bangalore and coworkers have shown that detection of methanol vapor from 400 - 7000 mg・kg<sup>−1</sup> in air can be accomplished by open path FT-IR spectroscopy, but this method requires quite bulky and expensive instruments that are not field deployable [<xref ref-type="bibr" rid="scirp.47036-ref11">11</xref>] . Pang and coworkers have used the sol-gel method to fabricate a planar waveguide ring resonator sensitive to ethanol with spectral dips that are red shifted when exposed to ethanol [<xref ref-type="bibr" rid="scirp.47036-ref24">24</xref>] . However, this technique has a small dynamic range (0 - 160 mg・kg<sup>−1</sup>) and the sensitivity of the resonant wavelength may be detected more precisely by spectroscopy than from loss measurements [<xref ref-type="bibr" rid="scirp.47036-ref24">24</xref>] . Hunter and coworkers have developed a technique for the measurement of ethanol concentrations in aqueous mixtures with a detection limit of 40 mg・kg<sup>−1</sup>, in which ethanol vapor is transported by a permeable membrane to a microelectromechanical (MEMS) chemi-capacitor array [<xref ref-type="bibr" rid="scirp.47036-ref25">25</xref>] . The dielectric constant of a polymeric material in the micro-capacitors increased upon absorption of ethanol vapor, leading to the measurement. All of the aforementioned techniques are based on physical (rather than chemical) detection methods.</p><p>Optical sensors are convenient to use for a variety of analytes because of their various advantages. Optical sensors are inexpensive, easy to produce, and therefore can be made into disposable chemical sensors if required [<xref ref-type="bibr" rid="scirp.47036-ref26">26</xref>] [<xref ref-type="bibr" rid="scirp.47036-ref27">27</xref>] . Maffei and coworkers have recently reported an alcohol vapor sensor using a fluorescent phosphonate cavitand. The reactions are mainly through hydrogen bonding between alcohols and the phosphonate cavitand, and the sensor is sensitive for C1-C4 alcohols ranging from 4 to 600 mg・kg<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.47036-ref28">28</xref>] . Other techniques of interest for alcohol detection involve silicon quantum dots coupled to fiber optics [<xref ref-type="bibr" rid="scirp.47036-ref29">29</xref>] and developing optical sensors from tetraphenyl porphyrins [<xref ref-type="bibr" rid="scirp.47036-ref30">30</xref>] . Also, Mohr and coworkers have produced an optical sensor for alcohols using a synthesized fluorescent compound Chromoionophore IX (CIX) prepared in a poly(vinyl chloride) (PVC) membrane for the detection of alcohols in the liquid phase [<xref ref-type="bibr" rid="scirp.47036-ref31">31</xref>] -[<xref ref-type="bibr" rid="scirp.47036-ref33">33</xref>] . We have adapted and developed sensors based on the fluorescence of CIX for the detection of methanol, ethanol, and 2-propanolin the gas phase.</p><p>With the goal of detecting various alcohols in the gas phase, optical sensors were developed using an ethyl cellulose (EC) thin-film matrix to encapsulate the dye in our studies. Their preparation has been optimized to produce sensitive sensors for alcohol vapors. The EC matrix has showed ideal performance and was selected after evaluating other matrices such as PVC and silica sol-gel. TiO<sub>2</sub> particles were used in the sensor films to induce Mie scattering, which increased the incident light interaction with the sensing films, and enhanced the sensitivity of the sensor [<xref ref-type="bibr" rid="scirp.47036-ref34">34</xref>] . The sensors show fast, reversible responses, and they are easily regenerated by flushing the sensor with nitrogen gas. The optical sensors have also been designed to function in a multianalyte platform for the simultaneous detection of multiple gas analytes. The studies here follow our earlier work in the development of optical sensors for chemicals in both liquid and gas phases [<xref ref-type="bibr" rid="scirp.47036-ref35">35</xref>] - [<xref ref-type="bibr" rid="scirp.47036-ref39">39</xref>] .<sup> </sup></p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Chemical Reagents and Materials</title><p>Ethyl cellulose (49% ethoxy content, MP Biomedicals), tridodecylmethylammonium chloride (TDMACl, 98%, Sigma-Aldrich), methyltriethoxysilane (MTEOS, Aldrich), tetramethoxysilane (TMOS, Aldrich), R706 TiO<sub>2</sub> (DuPont), and dioctyl sebacate (DOS, Sigma-Aldrich) were used as received. Methanol (99.9%), ethanol (99.9%), 2-propanol (99.9%), and other chemicals were purchased from Fisher Scientific. Chromoionophore IX (CIX) was either purchased from Fluka or prepared by the reported procedure [<xref ref-type="bibr" rid="scirp.47036-ref26">26</xref>] .</p><p>Standard microscope slides (Corning) were used to cut 1 &#180; 1 cm<sup>2</sup> glass sensor substrates. They were washed in a piranha solution (concentrated H<sub>2</sub>SO<sub>4</sub> and 30% H<sub>2</sub>O<sub>2</sub> in 3:1 ratio) for 30 min, followed by rinses first with deionized water and then with acetone, methanol, and ethanol. These slides were then dried in an oven before use. N-type [<xref ref-type="bibr" rid="scirp.47036-ref100">100</xref>] silicon wafers were similarly cleaned for deposition of thin film sensors that were then used for characterization by scanning electron microscopy (SEM).</p><p>A 0.9900% CO<sub>2</sub> gas tank (Airgas), odorless kerosene (Acros), acetone (Fischer), hexanes (Fischer), 29% aqueous ammonia solution, and food products, specifically bread, were used in the interference tests. To expose CO<sub>2</sub> gas to Sensor A, the CO<sub>2</sub> gas tank was directly connected to one of the flowmeters. After establishing a N<sub>2</sub> baseline, CO<sub>2</sub> gas (0.9900%) was introduced into the gas stream. In the interference tests involving kerosene, acetone, hexanes, and aqueous ammonia, approximately 50 mL of each analyte were placed into a temperature controlled jacketed gas impinger for their respective tests. After a baseline was established for Sensor A, nitrogen gas was introduced to the impinger to bubble the specific interferent vapor into the sensor flowcell, where the response was recorded. To test for food products, a breathing mask was fitted into the inlet of the flowcell and a volunteer would breath into the mask several times to establish a baseline of the breath and then ingest bread products. The volunteer would then breathe into the mask again to see if there were any differences between the two experiments.</p></sec><sec id="s2_2"><title>2.2. Preparation of EC Sensor Films (Sensors A, B and C)</title><p>A custom-built spin-coater was used to make the thin films.Ethyl cellulose (~0.235 g) was dissolved in a 4:1 mixture of toluene (8 mL) and ethanol (2 mL) to give a solution (2.5% wt EC) which, after several tests, was found to be of the optimal for the deposition of the sensor thin films. This solution was sonicated for 20 min and stirred to ensure that ethyl cellulose was completely dissolved. Then CIX (1 - 2 mg) and TDMACl (0.28 mg) were dissolved into 1.00 g of the solution with stirring. The ethyl cellulose solution containing the dye was pippetted on a cleaned glass slide (~1 &#180; 1 cm<sup>2</sup>), which was on the spin coater, and drawn to the edges of the glass slide with a plastic pipette tip. The slide was then spun at ~2600 rpm (revolutions per minute) for approximately 30 s. Schlenk tubes were used to store the freshly made thin-film sensors (Sensor A) under vacuum prior to use.</p><p>Sensors were also prepared by incorporating TiO<sub>2</sub> particles (360 nm diameter) to induce the Mie scattering. In the preparation of these sensors, R706 TiO<sub>2</sub> particles (~3.7 mg) were added to EtOH (5 mL) and sonicated for 20 min to disperse the particles. The EtOH solution containing the TiO<sub>2</sub> particles (100 μL) was added with additional EtOH (1.9 mL) and then mixed with toluene (8 mL) to give an ethyl cellulose solution (2.5% wt EC). Sonication was used to ensure that ethyl cellulose was completely dissolved. Thin film sensors on glass slides were prepared from this EC solution (Sensor B) in a process similar to that described above, and then stored under vacuum in a Schlenk tube before use.</p><p>Sensor C was prepared on silicon wafers as Sensor A.</p></sec><sec id="s2_3"><title>2.3. Instrumentation and Analytical Procedures</title><p>A Perkin-Elmer LS55 luminescence spectrometer with a pulsed Xe source was used for fluorescence measurements. The spectrometer was set at the following parameters: λ<sub>ex</sub> = 445 nm, λ<sub>em</sub> = 555 nm, 10 nm slits, 810 V PMT detector voltage, and a 515 nm emission cutoff filter. For time-based signal measurements, a signal reading was taken every 0.1 s. To improve the signal-to-noise ratio (S/N), signal averaging was used by the arithmetic mean of a point and the points before and after. Sensors were placed in a brass flow cell constructed to fit with a front surface sample cell holder purchased from Perkin-Elmer.</p><p>The vapor pressure of each alcohol at various temperatures was calculated by using the Antoine equation (Equation (1)), where A, B and C are constants over a defined temperature (T in K) range [<xref ref-type="bibr" rid="scirp.47036-ref40">40</xref>] .</p><disp-formula id="scirp.47036-formula21"><label>(1)</label><graphic position="anchor" xlink:href="http://html.scirp.org/file/4-2200918x6.png"  xlink:type="simple"/></disp-formula><p>A custom-made, jacketed gas impinger (<xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>) containing an alcohol liquid was used. The lid for the bubbler contained a medium frit gas diffuser immersed in the alcohol, and the lid was sealed by an O-ring and clamp. On top of the lid, there was a gas inlet for nitrogen gas and an outlet for the alcohol-saturated gas. The temperature of the jacketed impinger was controlled by a Thermo Haake temperature controller at −15.0, −7.0, and 0.0˚C to give 1.000% MeOH (wt%, 1.549 &#180; 10<sup>4</sup> ppm), 1.000% EtOH (1.587 &#180; 10<sup>4</sup> ppm), and 1.000% Pr<sup>i</sup>OH (2.310 &#180; 10<sup>4</sup> ppm), respectively. Two separate mass flow controllers (MKS Instruments) (<xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>) were connected to the inlet of the flow cell in the fluorescence spectrometer, and they were used to control the ratio of nitrogen <sub>&#173;</sub>gas and the gas from the impinger to obtain an accurate alcohol concentration. The outlet of the flowmeter was linked to a sealed vial which was attached to a separate bubbler to prevent the backflow of gases.</p><p>SEM images of Sensor C were taken using a Leo 1525 Field Emission Scanning Electron Microscope.</p></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Dye Sensing Mechanism</title><p>The CIX dye, a trifluoroacetyl, reacts with alcohol to give a hemiacetal (<xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>) and in the process quenches the fluorescence of the dye. However, formation of the hemiacetal takes approximately 20 h to complete. Mohr and coworkers found that a quaternary ammonium hydroxide, TDMACl, catalyzes the reaction resulting in an immediate conversion of the trifluoroacetyl group to the hemiacetal upon exposure to alcohol [<xref ref-type="bibr" rid="scirp.47036-ref33">33</xref>] . To our knowledge, the dye, CIX, has not been used for gas phase detection of alcohols or encapsulated in an ethyl cellulose matrix.</p></sec><sec id="s3_2"><title>3.2. Matrix Effects on Sensor Response</title><p>Initially, PVC sensors (Sensor D) were made following the formulation by Mohr and coworkers [<xref ref-type="bibr" rid="scirp.47036-ref33">33</xref>] . Upon exposure to air for several days, the PVC films lost a majority of their orange color, but were still responsive when</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref></label><caption><title> Schematic diagram of the instrumental set-up</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x7.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref></label><caption><title> Proposed mechanism for the reaction between the dye and an alcohol catalyzed by TDMACl [<xref ref-type="bibr" rid="scirp.47036-ref33">33</xref>] </title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x8.png"/></fig><p>tested under 1.000% Pr<sup>i</sup>OH pulses. The sensors, with an excitation peak at 450 nm, produced an emission peak at 540 nm (<xref ref-type="fig" rid="fig">Figure </xref>S1, Appendix). During pulses of nitrogen and 1.000% Pr<sup>i</sup>OH vapor, Sensor D showed quick response times by displaying a decrease in emission intensity and fast recovery times suitable for online measurements (<xref ref-type="fig" rid="fig">Figure </xref>S2, Appendix). In order to increase the sensitivity, Sensor E was prepared with twice the dye content. In the 0.036% - 1.000% Pr<sup>i</sup>OH vapor range (<xref ref-type="fig" rid="fig">Figure </xref>S3, Appendix), Sensor E showed better sensitivity. How- ever, the signal was noisy and it required signal averaging and baseline correction to adjust for the baseline drift.</p><p>Sol-gel sensors (Sensor F) were then explored as another alternative matrix for CIX. <xref ref-type="fig" rid="fig">Figure </xref>S4 shows the response of the sol-gel sensor to 1.000% Pr<sup>i</sup>OH pulses, Appendix. Initially, the response to Pr<sup>i</sup>OH was quick, but after switching back to nitrogen gas, the response was higher than the initial baseline, indicating that the sol-gel matrix perhaps has an affinity for alcohols and once exposed to alcohols reversibility may be problematic.</p><p>After several comparison tests, ethyl cellulose (EC) was found to be the best matrix to encapsulate the dye CIX. A focus on EC as the matrix for CIX also helped to provide consistency with other sensors previously studied by Innosense LLC in a multi-channel sensing platform. Sensor A produced an emission peak at 555 nm when the dye was excited at 445 nm (<xref ref-type="fig" rid="fig">Figure </xref>3).</p><p><xref ref-type="fig" rid="fig">Figure </xref>4(a) shows a section of a uniform pitted surface of Sensor C on a silicon substrate at 900&#215; magnification from SEM imaging. <xref ref-type="fig" rid="fig">Figure </xref>4(b) displays a cross section of Sensor C at 3000&#215; magnification that has a</p><fig-group id="fig3"><label><xref ref-type="fig" rid="fig">Figure </xref>3</label><caption><title> (a) Spectra of Sensor A: a. excitation; b. emission; c. emission after exposure to 1.000% Pr<sup>i</sup>OH; (b) Time-based emission at 555 nm demonstrating a signal quenching response when exposed to 1.000% Pr<sup>i</sup>OH in nitrogen gas without signal averaging or background correction. arb = arbitrary unit.</title></caption><fig id ="fig3_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x9.png"/></fig><fig id ="fig3_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x10.png"/></fig></fig-group><fig-group id="fig4"><label><xref ref-type="fig" rid="fig">Figure </xref>4</label><caption><title> SEM images of Sensor C: (a) Surface; (b) Cross section.</title></caption><fig id ="fig4_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x12.png"/></fig><fig id ="fig4_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x11.png"/></fig></fig-group><p>thickness of 1 - 2 &#181;m, highlighted by the two parallel lines in the image. The surface of the sensor shows features (“pitting”) consistent with phase separation that occurs during the processing of the sensor.</p></sec><sec id="s3_3"><title>3.3. Mie Scattering with TiO<sub>2</sub> Particles</title><p>In order to increase the sensitivity of the indicator dye, TiO<sub>2</sub> particles were incorporated into ethyl cellulose thin films. TiO<sub>2</sub> particles scatter wavelengths in the visible range about equally [<xref ref-type="bibr" rid="scirp.47036-ref34">34</xref>] . The scattering of light by the TiO<sub>2</sub> particles within the sensing matrix allows for a more effective interaction of light with the indicator molecules in the sensing layer, thus effectively increasing the path length without using thicker sensing layers [<xref ref-type="bibr" rid="scirp.47036-ref34">34</xref>] . The optimum particle size would be approximately 0.5 times the wavelength of interest which, in this case, would be around 250 - 350 nm for the emission wavelength of 550 nm from the dye. This method was adapted from CO<sub>2 </sub>sensors that we developed recently [<xref ref-type="bibr" rid="scirp.47036-ref39">39</xref>] . One possible method using TiO<sub>2</sub> particles would be to prepare size-controlled TiO<sub>2</sub> particles so that it would correspond to the optimum particle size needed for the emission wavelength. Nakata and coworkers have fabricated and characterized self-organized porous TiO<sub>2</sub> particle layers where the particle size can be modified depending on the calcination temperature and time [<xref ref-type="bibr" rid="scirp.47036-ref41">41</xref>] . You and coworkers have also developed a process to prepare submicron-sized porous TiO<sub>2</sub> particles by a single-step swelling process of polystyrene template particles with titanium (IV) isopropoxide (TTIP) [<xref ref-type="bibr" rid="scirp.47036-ref42">42</xref>] . However, commercial TiO<sub>2</sub> particles R706 were used instead because it was inexpensive and readily available. <xref ref-type="fig" rid="fig">Figure </xref>5 shows the response of TiO<sub>2</sub>-doped Sensor B. The addition of TiO<sub>2 </sub>R706 particles resulted in an increase in the emission intensity. This is most likely because the median size of R706 particles, at 360 nm [<xref ref-type="bibr" rid="scirp.47036-ref43">43</xref>] , is close to the 250 - 350 nm range indicated above. Moreover, according to the DuPont’s R706 product sheet, small TiO<sub>2</sub> particles scatter</p><fig id="fig5"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>5</label><caption><title> Comparison between Sensor A and TiO<sub>2</sub>-doped Sensor B; (a) Sensor B; (b) Sensor B when exposed to 1.000% Pr<sup>i</sup>OH; (c) Sensor A; (d) Sensor A when exposed to 1.000% Pr<sup>i</sup>OH</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x13.png"/></fig><p>blue light more effectively than those with larger particle sizes [<xref ref-type="bibr" rid="scirp.47036-ref43">43</xref>] . In addition, R706 is ideal for the prototype optoelectronic device using a blue LED as its light source discussed below.</p></sec><sec id="s3_4"><title>3.4. Analytical Performance</title><p>As indicated earlier, reactions of the dye CIX with alcohols forming hemiacetals are selective. Primary alcohols with increasing chain lengths show an increasing ratio of the trifluoroacetyl form rather than the product hemiacetals [<xref ref-type="bibr" rid="scirp.47036-ref33">33</xref>] . <xref ref-type="fig" rid="fig">Figure </xref>6 shows the sensitivity of the EC sensor towards MeOH, EtOH, and Pr<sup>i</sup>OH, respectively. Linear calibrations are obtained over large concentration ranges. The detection limits are 9, 13, 21 mg・kg<sup>−1</sup>, and the quantification limits are 32, 43, and 70 mg・kg<sup>−1</sup>, respectively, for MeOH, EtOH, and Pr<sup>i</sup>OH vapors. The data show that the sensors are in general more sensitive to less bulky alcohols. Since CIX reacts with different alcohols, it is important to place the sensor in a specific location where the type of alcohol is known. For example, the alcohol sensor could be positioned to detect methanol leaks from fuel cells that are used in microelectronics or be adapted into breathalyzers for ethanol intoxication.</p><p>Compared to other previously mentioned studies of alcohol sensors, the EC-CIX sensors developed in this study have a much higher dynamic range and lower limit of detection for the alcohols investigated. Commercial alcohol gas sensors such as the ones used in breathalyzers usually have a sensor accuracy of &#177;0.01 blood alcohol content (BAC), according to commercial product specifications, which indicates the readings can vary by as much as 100 mg・kg<sup>−1</sup> [<xref ref-type="bibr" rid="scirp.47036-ref44">44</xref>] - [<xref ref-type="bibr" rid="scirp.47036-ref46">46</xref>] . While the EC-CIX sensors in this study are not totally unaffected by interferences such as moisture and amines, they are less sensitive to other interferent constituents that are found in rocket fuel and plumes such as CO<sub>2</sub> and kerosene. The interference studies suggest that the alcohol sensors should be used in environments where the analyte gas is known so interferent vapors such as moisture/amines and other specific alcohols do not interfere in the detection. The research here shows that EC-CIX sensors may be considered an option as a sensitive alcohol sensor for detection in rocket plumes as well as being adapted and providing an improvement to general alcohol sensing device.</p></sec><sec id="s3_5"><title>3.5. Storage Conditions and Long Term Studies</title><p>Unlike the PVC sensors (Sensors D and E), the EC sensors (Sensor A) were able to keep their fluorescent orange color and demonstrated durability under ambient environment. An EC matrix helped to stabilize the baseline response which was observed by the small difference between the original and baseline corrected response (<xref ref-type="fig" rid="fig">Figure </xref>S5) when the sensor was exposed to Pr<sup>i</sup>OH vapor, Appendix. Since the EC thin-film sensors do not lose their initial sensitivity in ambient environment, a long term study was performed to test the durability of the sensors. In order to simulate real-world field tests, Sensor As were wrapped in a lint-free cloth and then covered</p><fig id="fig6"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>6</label><caption><title> Response of Sensor A to MeOH vapors-Calibration: y = 0.1517x − 0.0021 (R<sup>2</sup> = 0.998) based on data in the range of 0% - 1.000% (0 - 1.549 &#180; 10<sup>4</sup> ppm) MeOH; EtOH vapors-Calibration: y = 0.3476x − 0.0045 (R<sup>2</sup> = 0.996) based on data in the range of 0% - 1.000% (0 - 1.587 &#180; 10<sup>4</sup> ppm) EtOH; and Pr<sup>i</sup>OH vapors-Calibration: y = 0.0926x + 0.0123 (R<sup>2</sup> = 0.998) based on data in the range of 0% - 1.000% (0 - 2.310 &#180; 10<sup>4</sup> ppm) Pr<sup>i</sup>OH</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x14.png"/></fig><p>in aluminum foil to protect the sensors from light. Afterwards, the sensors were placed in sealable bags. Fluorescence measurements were performed every 2 weeks on the same sensor (Sensor A1), which was compared to a freshly opened sensor from the same batch. Over a period of eight months, Sensor A1 began to fluctuate in baseline (<xref ref-type="fig" rid="fig">Figure </xref>S6) but the sensor still showed sensitivity when exposed to alcohol vapor (Pr<sup>i</sup>OH). In comparison, freshly opened sensors for each measurement showed a baseline and sensitivity similar to that of Sensor A1 from month 1. This long term study demonstrates that Sensor A is able to optimally detect alcohol for 3 months before it needs to be replaced, and the sensor can remain sensitive for up to a year.</p></sec><sec id="s3_6"><title>3.6. Multi-Channel Prototype Platform</title><p>To demonstrate that these alcohol sensors can be used in the field, InnoSense LLC has designed and built a miniaturized multi-channel optoelectronic device that can test up to seven different sensors simultaneously from a blue LED light source. Each channel has a slot for an optical filter to enable absorbance or fluorescence based measurements and longpass filters (500 nm) were used to examine the EC-CIX alcohol sensors. Within the optoelectronic sensor unit, there is a built-in temperature and humidity probe to monitor temperature and relative humidity during the testing period. Therefore, any contribution from humidity can be subtracted from the signal, thus giving the signal arising from the alcohol analyte itself. The optoelectronic sensor unit can be connected to a PC where data acquisition is monitored by LiveGraph software. The sensor unit was evaluated by testing three alcohol sensors (Sensor A) and an EC blank and exposing these sensors to varying concentrations of Pr<sup>i</sup>OH ranging from 0% - 1.000%. Data was taken every 5 s. <xref ref-type="fig" rid="fig">Figure </xref>7 displays the results from the sensor unit. Each alcohol sensor shows a similar response to the other and demonstrates an expected decrease in signal upon exposure to Pr<sup>i</sup>OH. The sensors showed minute changes in signal within the optoelectronic device when exposing the alcohol sensors to CO<sub>2</sub> gas. However, these results were expected given the previous results above.</p></sec><sec id="s3_7"><title>3.7. Interference Study</title><p>Another challenge for detection in optical sensors is interferences. To evaluate the response of the alcohol sensor</p><fig-group id="fig7"><label><xref ref-type="fig" rid="fig">Figure </xref>7</label><caption><title> Response of three alcohol sensors (Sensor A) in the prototype optoelectronic device in channels B, C, and E when exposed to Pr<sup>i</sup>OH vapor and CO<sub>2</sub>.</title></caption><fig id ="fig7_1"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x15.png"/></fig><fig id ="fig7_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x16.png"/></fig><fig id ="fig7_3"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x17.png"/></fig></fig-group><p>to interferent vapors, carbon dioxide (CO<sub>2</sub>), kerosene, ammonia (NH<sub>3</sub>), moisture (H<sub>2</sub>O), hexanes, acetone, and food were directly exposed to Sensor A in triplicate and recorded. Kerosene is a rocket fuel, and CO<sub>2</sub> is a major component of rocket plumes. NH<sub>3</sub> is a primary product of hydrazine (H<sub>2</sub>NNH<sub>2</sub>) decomposition, and hydrazine has been used as a liquid rocket propellant [<xref ref-type="bibr" rid="scirp.47036-ref47">47</xref>] [<xref ref-type="bibr" rid="scirp.47036-ref48">48</xref>] . Moisture is a byproduct generated through the combustion of 2-propanol with liquid oxygen in order to simulate a vacuum for rocket testing [<xref ref-type="bibr" rid="scirp.47036-ref16">16</xref>] . Acetone, hexanes, and food products, specifically bread, are some of the interferences that have attributed to false positives in general commercial alcohol sensors [<xref ref-type="bibr" rid="scirp.47036-ref49">49</xref>] .</p><p>As expected, <xref ref-type="fig" rid="fig">Figure </xref>S7 shows that CO<sub>2</sub> gas has a minute effect on Sensor A, and the observation is consistent with the fact that CO<sub>2</sub> does not react with the CIX dye. Exposing Sensor A to kerosene vapors caused the fluorescence of the sensor to slightly quench in intensity, suggesting that the introduction of the hydrophobic kerosene to the sensor film may have changed the environment, shifting to a small degree the equilibrium of the reaction between the CIX dye and alcohol (<xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>). It is expected that vapors of other organic hydrocarbons may lead to a similar, small effect.</p><p>However, exposing Sensor A to ammonia vapor and moisture caused a large decrease in fluorescence of the sensor. Other amines, especially primary amines, may react with the CIX dye and quench its fluorescence [<xref ref-type="bibr" rid="scirp.47036-ref50">50</xref>] . Moreover, moisture can react with the CIX dye, a ketone, forming geminal diols and thus affect the reaction of the dye with alcohol [<xref ref-type="bibr" rid="scirp.47036-ref50">50</xref>] . Since Sensor A is being used in an optoelectronic sensor unit with a built in humidity probe, the relative humidity can be measured during the testing period. Thus, the relative humidity can be measured and be subtracted from the signal. Studies are also underway to develop a dual optical sensing approach to address the impact of moisture, and the results will be reported in the future.</p><p>General alcohol sensors such as commercial breathalyzers may also be susceptible to outside interferences such as food and other chemicals in the environment, leading to readings higher than normal and false positives [<xref ref-type="bibr" rid="scirp.47036-ref50">50</xref>] . The US National Highway Traffic Safety Administration (NHTSA) establishes guidelines and screenings for commercial breathalyzers in order to be approved as an alcohol sensing device [<xref ref-type="bibr" rid="scirp.47036-ref51">51</xref>] . These guidelines do not require a certain limit of detection to be met but require devices to conform to a set of tests to evaluate the precision and accuracy of the alcohol sensing device [<xref ref-type="bibr" rid="scirp.47036-ref51">51</xref>] .</p><p>One of the major flaws of IR breathalyzers is the lack of specificity, since it is often the methyl group in ethanol that is being detected [<xref ref-type="bibr" rid="scirp.47036-ref49">49</xref>] . Thus the sensor will treat any compound with a methyl group as ethanol which includes many chemical compounds whose molecular structures are compatible with IR filters. Two IR wavelengths and an algorithm for the detection of interferents have been used in new breathanalyzers to calculate the ratio of absorbance values at the two measured wavelengths [<xref ref-type="bibr" rid="scirp.47036-ref50">50</xref>] . Also, the instrumentation for IR breathanalyzers can be complex with some requiring five filters to address volatile interferences [<xref ref-type="bibr" rid="scirp.47036-ref52">52</xref>] . Although such an approach reduces interference, acetone, e.g., was found to still have an effect on the new, IR-based breathanalyzers [<xref ref-type="bibr" rid="scirp.47036-ref53">53</xref>] . Semiconductor breathalyzers have been shown to absorb many substances which can give positive alcohol readings even when no ethanol is present [<xref ref-type="bibr" rid="scirp.47036-ref49">49</xref>] . Studies have confirmed the existence of a wide variety of compounds on the human breath [<xref ref-type="bibr" rid="scirp.47036-ref54">54</xref>] . Acetone and hexanes are among chemicals that are commonly found on the breath of normal, healthy individuals but are of insignificant levels to affect breathalyzers. However, dieters and diabetics not in control of their blood sugar can have acetone levels hundreds or even thousands of times higher than normal which may create falsely high results in a semiconductor breathalyzer [<xref ref-type="bibr" rid="scirp.47036-ref49">49</xref>] . Breathalyzers based on fuel cell technology give concerns due to sensitivity loss and sensor degradation after long term exposure in dry conditions [<xref ref-type="bibr" rid="scirp.47036-ref55">55</xref>] . The primary reason for sensitivity loss and sensor degradation is from the loss of electrochemically active surface area of the platinum electrode, which is seemingly irreversible [<xref ref-type="bibr" rid="scirp.47036-ref55">55</xref>] . Another concern for fuel cell sensors, albeit to a lesser extent, is the loss of proton conductivity as a result of membrane dehydration but can be alleviated by rehydrating the membrane in humid conditions [<xref ref-type="bibr" rid="scirp.47036-ref55">55</xref>] . There has been a report of a false-positive breath-alcohol test using a fuel-cell based analyzer after a ketogenic diet [<xref ref-type="bibr" rid="scirp.47036-ref56">56</xref>] .</p><p>In comparison to commercial breathalyzers, Sensor A appears to be less prone to common interferences of current commercial alcohol sensors. Sensor A was directly exposed to interferents that are known for commercial breathalyzers such as acetone, hexanes, and food but gave a minute response to these interferences (<xref ref-type="fig" rid="fig">Figure </xref>S7). The small responses are perhaps a result of solvent effects, as acetone [<xref ref-type="bibr" rid="scirp.47036-ref57">57</xref>] and hexanes do not react with the CIX dye. It is unclear why food interferes with common breathalyzers since it can cause one of the highest false positives in commercial breathalyzers [<xref ref-type="bibr" rid="scirp.47036-ref58">58</xref>] . However, it does not affect the response of Sensor A. The interference study here demonstrates that interferences without active N-H or O-H groups are unlikely to interfere with the response of Sensor A. The current study looks into a new method centered on a fluorescence based system for the detection of alcohol and provides an improvement over existing alcohol sensors by limiting the possible interferences that may affect a reading such as chemicals or dry conditions.</p></sec></sec><sec id="s4"><title>4. Conclusion</title><p>In this study, the CIX dye was incorporated into EC films in order to detect alcohol vapors. The ethyl cellulose sensor for alcohol vapors was sensitive to MeOH, EtOH, and Pr<sup>i</sup>OH. To induce Mie scattering, TiO<sub>2</sub> particles were added to the alcohol sensors to increase the interaction of light with the indicator material which enhanced the sensitivity of the sensors. The use of TiO<sub>2</sub> particles increased the signal of the emission intensity by approximately 30%. The alcohol gas sensor reported in this study has a much higher dynamic range and lower limit of detection for the alcohols studied than the other gas alcohol sensors reported earlier. Among the interferences tested that are known to interfere with common alcohol sensors such as acetone, hexanes, and food vapors, they were shown not to interfere with the sensor in this study. Sensor A was tested with a miniaturized multi-channel testing platform, showing that they could be used under real world field testing conditions. The work found in this study may lead to the possibility of an optical sensor useful for a variety of different applications.</p></sec><sec id="s5"><title>Acknowledgements</title><p>This work was supported by the NASA STTR program (07-1 T9.01-9883) and the US National Science Foundation (CHE-1012173 to ZLX).</p></sec><sec id="s6"><title>Appendix. Supplementary Data</title><p>The following supplementary data associated with this article can be found in the online version: Spectra of Sensor D (<xref ref-type="fig" rid="fig">Figure </xref>S1); Responses of Sensors D (<xref ref-type="fig" rid="fig">Figure </xref>S2 and <xref ref-type="fig" rid="fig">Figure </xref>S3), F (<xref ref-type="fig" rid="fig">Figure </xref>S4), and A (<xref ref-type="fig" rid="fig">Figure </xref>S5) to Pr<sup>i</sup>OH vapor; Baseline study of Sensor A over the 8-month period (<xref ref-type="fig" rid="fig">Figure </xref>S6); Response of Sensor A to interferent vapors CO<sub>2</sub>, kerosene, ethylene glycol, and NH<sub>3</sub> (<xref ref-type="fig" rid="fig">Figure </xref>S7).</p></sec><sec id="s7"><title>Supporting Material</title><fig id="fig8"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>S1</label><caption><title> Excitation/Emission spectra of PVC Sensor D and signal quenching upon exposure to 1.092 mol% Pr<sup>i</sup>OH vapor</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x18.png"/></fig><fig id="fig9"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>S2</label><caption><title> Time-based emission of Sensor D at 540 nm demonstrating a signal quenching response when exposed to 1.092 mol% Pr<sup>i</sup>OH in nitrogen gas without signal averaging or background correction</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x19.png"/></fig><fig id="fig10"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>S3</label><caption><title> Response of Sensor D to 0.0364 - 1.092 mol% Pr<sup>i</sup>OH with signal averaging and baseline correction</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x20.png"/></fig><fig id="fig11"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>S4</label><caption><title> Response of the sol-gel Sensor F on exposure to 1.092 mol% pulses of Pr<sup>i</sup>OH vapor; Emission was detected at 580 nm</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x21.png"/></fig><fig id="fig12"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>S5</label><caption><title> Response of Sensor A to Pr<sup>i</sup>OH vapors</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x22.png"/></fig><fig-group id="fig13"><label><xref ref-type="fig" rid="fig">Figure </xref>S6</label><caption><title> Baseline study of Sensor A: (a) One sensor over an 8-month period; (b) Freshly opened sensors over an 8-month period.</title></caption><fig id ="fig13_1"><label> (b)</label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x24.png"/></fig><fig id ="fig13_2"><label></label><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x23.png"/></fig></fig-group><fig id="fig14"  position="float"><label><xref ref-type="fig" rid="fig">Figure </xref>S7</label><caption><title> Response of the alcohol sensor to interferent vapor CO<sub>2</sub>, kerosene, ethylene glycol, and NH<sub>3</sub></title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/4-2200918x25.png"/></fig></sec><sec id="s8"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.47036-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Costantini, M.G. (1993) Health Effects of Oxygenated Fuels. Environmental Health Perspectives, 101, 151-160. http://dx.doi.org/10.1289/ehp.93101s6151</mixed-citation></ref><ref id="scirp.47036-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Flipsen, B. (2010) Designing Microfuel Cells for Portable Electronics. Journal of Fuel Cell Science and Technology, 7, Article ID: 061014. http://dx.doi.org/10.1115/1.4001352</mixed-citation></ref><ref id="scirp.47036-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">http://www.epa.gov/ttn/atw/187polls.html</mixed-citation></ref><ref id="scirp.47036-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Young, J.A. (2006) Methanol. Journal of Chemical Education, 83, 1131. http://dx.doi.org/10.1021/ed083p1131</mixed-citation></ref><ref id="scirp.47036-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">http://www.osha.gov/dts/chemicalsampling/data/CH_251600.html</mixed-citation></ref><ref id="scirp.47036-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Finkelstein, Y. and Vardi, J. (2002) Progressive Parkinsonism in a Young Experimental Physicist Following Long-Term Exposure to Methanol. NeuroToxicology, 23, 521-525. http://dx.doi.org/10.1016/S0161-813X(02)00033-5</mixed-citation></ref><ref id="scirp.47036-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Federal Register (2010) Environmental Protection Agency, 68094-68150.</mixed-citation></ref><ref id="scirp.47036-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Torsner, E. (2010) Solving Corrosion Problems in Biofuels Industry. Corrosion Engineering Science and Technology, 45, 42-48. http://dx.doi.org/10.1179/147842209X12579401586726</mixed-citation></ref><ref id="scirp.47036-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Oliverio, N., Jiang, L., Yilmaz, H. and Stefanopoulou, A. (2009) Ethanol Detection in Flex-Fuel Direct Injection Engines Using In-Cylinder Pressure Measurements. SAE International Journal of Fuels and Lubricants, 2, 229-241.</mixed-citation></ref><ref id="scirp.47036-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Y., Zhi, Z. and Yang, F. (2010) Highly Sensitive and Selective Alcohol Sensor Based on Ag-Doped In2O3 Coating. Industrial &amp; Engineering Chemistry Research, 49, 3539-3543. http://dx.doi.org/10.1021/ie100197b</mixed-citation></ref><ref id="scirp.47036-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Bangalore, A.S., Small, G.W., Combs, R.J., Knapp, R.B. and Kroutil, R.T. (1994) Automated Detection of Methanol Vapor by Open Path Fourier Transform Infrared Spectrometry. Analytica Chimica Acta, 297, 387-403. http://dx.doi.org/10.1016/0003-2670(94)00241-X</mixed-citation></ref><ref id="scirp.47036-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Criddle, W.J., Parry, K.W. and Jones, T.P. (1987) On-Line Determination of Ethanol during Fermentation Process Using a Fuel Cell Sensor. Analyst, 112, 615-618. http://dx.doi.org/10.1039/an9871200615</mixed-citation></ref><ref id="scirp.47036-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Win, D.T. (2006) Breath Alcohol Testers—Prevents Road Accidents. AU Journal of Technology, 10, 75-80. http://www.journal.au.edu/au_techno/2006/oct06/journalTechV10N2_aticle01.pdf</mixed-citation></ref><ref id="scirp.47036-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Monblanc, P. and Lacan, B. (2005) US Patent No. 6942835 B2.</mixed-citation></ref><ref id="scirp.47036-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Gonzalez, M.H., Araujo, G.C.L., Pelizaro, C.B., Menezes, E.A., Lemos, S.G., Batista de Sousaa, G. and Nogueira, A.R.A. (2008) Coconut Coir as Biosorbent for Cr(VI) Removal from Laboratory Wastewater. Journal of Hazardous Material, 159, 252-256. http://dx.doi.org/10.1016/j.jhazmat.2008.02.014</mixed-citation></ref><ref id="scirp.47036-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Morey, T.E., Booth, M.M., Prather, R.A., Nixon, S.J., Boissoneault, J., Melker, R.J., Goldberger, B.A., Wohltjen, H. and Dennis, D.M. (2011) Measurement of Ethanol in Gaseous Breath Using a Miniature Gas Chromatograph. Journal of Analytical Toxicology, 35, 134-142. http://dx.doi.org/10.1093/anatox/35.3.134</mixed-citation></ref><ref id="scirp.47036-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Gessei, T., Sato, H., Kazawa, E., Kudo, H., Saito, H. and Mitsubayashi, K. (2009) Bio-Sniffers for Ethanol and Acetaldehyde Using Carbon and Ag/AgCl Coated Electrodes. Microchimica Acta, 165, 179-186. http://dx.doi.org/10.1007/s00604-008-0117-z</mixed-citation></ref><ref id="scirp.47036-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">NASA Stennis Space Center (2007) Environmental Assessment for the Construction and Operation of the Constellation Program A-3 Test Stand. http://www.ssc.nasa.gov/environmental/docforms/eas/eas.html</mixed-citation></ref><ref id="scirp.47036-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Tejwani, G.D., McVay, G.P., Langford, L.A. and St. Cyr, W.W. (2006) Planning for Plume Diagnostics for Ground Testing J-2X Engines at the SSC. Stennis Space Center, NASA. http://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20100003145_2010002997.pdf</mixed-citation></ref><ref id="scirp.47036-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">http://www.osha.gov/dts/chemicalsampling/data/CH_248400.html</mixed-citation></ref><ref id="scirp.47036-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Dhillon, S. and von Burg, R. (1995) Isopropyl Alcohol. Journal of Applied Toxicology, 15, 501-506. http://dx.doi.org/10.1002/jat.2550150612</mixed-citation></ref><ref id="scirp.47036-ref22"><label>22</label><mixed-citation publication-type="other" xlink:type="simple">Jones, A.W. (1992) Driving under the Influence of Isopropyl. Clinical Toxicology, 30, 153-155. http://dx.doi.org/10.3109/15563659208994457</mixed-citation></ref><ref id="scirp.47036-ref23"><label>23</label><mixed-citation publication-type="other" xlink:type="simple">Stevens, N. and Akins, D.L. (2007) Dye-Doped Inorganic/Organic Composite Films as Fluorescence Sensors for Methanol Vapor. Sensors and Actuators B, 123, 59-64. http://dx.doi.org/10.1016/j.snb.2006.07.021</mixed-citation></ref><ref id="scirp.47036-ref24"><label>24</label><mixed-citation publication-type="other" xlink:type="simple">Pang, F., Han, X., Chu, F., Geng, J., Cai, H., Qu, R. and Fang, Z. (2007) Sensitivity to Alcohols of a Planar Waveguide Ring Resonator Fabricated by a Sol-Gel Method. Sensors and Actuators B, 120, 610-614. http://dx.doi.org/10.1016/j.snb.2006.03.031</mixed-citation></ref><ref id="scirp.47036-ref25"><label>25</label><mixed-citation publication-type="other" xlink:type="simple">McCorkle, D.L., Warmack, R.J., Patel, S.V., Mlsna, T., Hunter, S.R. and Ferrell, T.L. (2005) Ethanol Vapor Detection in Aqueous Environments Using Micro-Capacitors and Dielectric Polymers. Sensors and Actuators B, 107, 892-903. http://dx.doi.org/10.1016/j.snb.2004.12.051</mixed-citation></ref><ref id="scirp.47036-ref26"><label>26</label><mixed-citation publication-type="other" xlink:type="simple">Stich, M.I.J., Fischer, L.H. and Wolfbeis, O.S. (2010) Multiple Fluorescent Chemical Sensing and Imaging. Chemical Society Reviews, 39, 3102-3114. http://dx.doi.org/10.1039/b909635n</mixed-citation></ref><ref id="scirp.47036-ref27"><label>27</label><mixed-citation publication-type="other" xlink:type="simple">Holthoff, E.L. and Bright, F.V. (2007) Molecularly Imprinted Xerogels as Platforms for Sensing. Accounts of Chemical Research, 40, 756-767. http://dx.doi.org/10.1021/ar700087t</mixed-citation></ref><ref id="scirp.47036-ref28"><label>28</label><mixed-citation publication-type="other" xlink:type="simple">Maffei, F., Betti, P., Genovese, D., Montalti, M., Prodi, L., Zorzi, R.D., Geremia, S. and Dalcanale, E. (2011) Highly Selective Chemical Vapor Sensing by Molecular Recognition: Specific Detection of C1-C4 Alcohols with a Fluorescent Phosphonate Cavitand. Angewandte Chemie International Edition, 50, 4654-4657.</mixed-citation></ref><ref id="scirp.47036-ref29"><label>29</label><mixed-citation publication-type="other" xlink:type="simple">Tonezzer, M., Quaranta, A., Maggioni, G., Carturan, S. and Mea, G.D. (2007) Optical Sensing Responses of Tetraphenyl Porphyrins toward Alcohol Vapours: A Comparison between Vacuum Evaporated and Spin-Coated Thin Films. Sensors and Actuators B: Chemical, 122, 620-626. http://dx.doi.org/10.1016/j.snb.2006.07.009</mixed-citation></ref><ref id="scirp.47036-ref30"><label>30</label><mixed-citation publication-type="other" xlink:type="simple">Zhang, Z.H., Lockwood, R., Veinot, J.G.C. and Meldrum, A. (2013) Detection of Ethanol and Water Vapor with Silicon Quantum Dots Coupled to an Optical Fiber. Sensors and Actuators B: Chemical, 181, 523-528. http://dx.doi.org/10.1016/j.snb.2013.01.070</mixed-citation></ref><ref id="scirp.47036-ref31"><label>31</label><mixed-citation publication-type="other" xlink:type="simple">Mohr, G.J., Citterio, D. and Spichiger-Keller, U.E. (1998) Development of Chromogenic Reactands for Optical Sensing of Alcohols. Sensors and Actuators B, 49, 226-234. http://dx.doi.org/10.1016/S0925-4005(98)00132-4</mixed-citation></ref><ref id="scirp.47036-ref32"><label>32</label><mixed-citation publication-type="other" xlink:type="simple">Mohr, G.J. and Spichiger-Keller, U.E. (1997) Novel Fluorescent Sensor Membranes for Alcohols Based on p-N,N-di- octylamino-4’-Trifluoroacetylstilbene. Analytica Chimica Acta, 351, 189-196. http://dx.doi.org/10.1016/S0003-2670(97)00365-6</mixed-citation></ref><ref id="scirp.47036-ref33"><label>33</label><mixed-citation publication-type="other" xlink:type="simple">Mohr, G.J., Lehmann, F., Grummt, U. and Spichiger-Keller, U.E. (1997) Fluorescent Ligands for Optical Sensing of Alcohols: Synthesis and Characterisation of p-N,N-dialkylamino-Trifluoroacetylstilbenes. Analytica Chimica Acta, 344, 215-225. http://dx.doi.org/10.1016/S0003-2670(97)00113-X</mixed-citation></ref><ref id="scirp.47036-ref34"><label>34</label><mixed-citation publication-type="other" xlink:type="simple">Wriedt, T. (1998) A Review of Elastic Light Scattering Theories. Particle &amp; Particle Systems Characterization, 15, 67-74. http://dx.doi.org/10.1002/(SICI)1521-4117(199804)15:2&lt;67::AID-PPSC67&gt;3.0.CO;2-F</mixed-citation></ref><ref id="scirp.47036-ref35"><label>35</label><mixed-citation publication-type="other" xlink:type="simple">Carrington, N.A., Thomas, G.H., Rodman, D.L., Beach, D.B. and Xue, Z.L. (2007) Optical Determination of Cr(VI) Using Regenerable, Functionalized Sol-Gel Monoliths. Analytica Chimica Acta, 581, 232-240. http://dx.doi.org/10.1016/j.aca.2006.08.032</mixed-citation></ref><ref id="scirp.47036-ref36"><label>36</label><mixed-citation publication-type="other" xlink:type="simple">Allain, L.R. and Xue, Z.L. (2000) Optical Sensors for the Determination of Concentrated Hydroxide. Analytical Chemistry, 72, 1078-1083. http://dx.doi.org/10.1021/ac990908b</mixed-citation></ref><ref id="scirp.47036-ref37"><label>37</label><mixed-citation publication-type="other" xlink:type="simple">Canada, T.A. and Xue, Z.L. (2002) High-Basicity Determination in Mixed Water-Alcohol Solutions by a Dual Optical Sensor Approach. Analytical Chemistry, 74, 6073-6079. http://dx.doi.org/10.1021/ac0202987</mixed-citation></ref><ref id="scirp.47036-ref38"><label>38</label><mixed-citation publication-type="other" xlink:type="simple">Fong, J.K. and Xue, Z.L. (2013) A Dye-Doped Optical Sensor for the Detection of Biodiesel in Diesel. Chemical Communications, 49, 9015-9017. http://dx.doi.org/10.1039/c3cc43958e</mixed-citation></ref><ref id="scirp.47036-ref39"><label>39</label><mixed-citation publication-type="other" xlink:type="simple">Dansby-Sparks, R.N., Jin, J., Mechery, S.J., Sampathkumaran, U., Owen, T.W., Yu, B.D., Goswami, K., Hong, K., Grant, J. and Xue, Z.L. (2010) Fluorescent-Dye-Doped Sol-Gel Sensor for Highly Sensitive Carbon Dioxide Gas Detection below Atmospheric Concentrations. Analytical Chemistry, 82, 593-600. http://dx.doi.org/10.1021/ac901890r</mixed-citation></ref><ref id="scirp.47036-ref40"><label>40</label><mixed-citation publication-type="other" xlink:type="simple">Dean, J.A. (1999) Lange’s Handbook of Chemistry. 15th Edition, McGraw-Hill, New York, 5.30.</mixed-citation></ref><ref id="scirp.47036-ref41"><label>41</label><mixed-citation publication-type="other" xlink:type="simple">Nakata, K., Sakai, M., Ochiai, T., Murakami, T., Takagi, K. and Fujishima, A. (2012) Fabrication and Characterization of Self-Organized Porous TiO2 Particle Layers. Materials Letters, 70, 160-162. http://dx.doi.org/10.1016/j.matlet.2011.12.016</mixed-citation></ref><ref id="scirp.47036-ref42"><label>42</label><mixed-citation publication-type="other" xlink:type="simple">You, J.H. and Hsu, K.Y. (2010) Preparation of Submicron-Sized Porous Titanium Oxide Particles by the Swelling Process. Chemical Engineering Research and Design, 88, 1049-1056. http://dx.doi.org/10.1016/j.cherd.2010.01.033</mixed-citation></ref><ref id="scirp.47036-ref43"><label>43</label><mixed-citation publication-type="other" xlink:type="simple">DuPont’s R706 Product Sheet.</mixed-citation></ref><ref id="scirp.47036-ref44"><label>44</label><mixed-citation publication-type="other" xlink:type="simple">AlcoMate AL-7000 Product Sheet. http://alcomate.net/prodmanuals/manual_Premium.pdf</mixed-citation></ref><ref id="scirp.47036-ref45"><label>45</label><mixed-citation publication-type="other" xlink:type="simple">AlcoHawk Precision Product Sheet. http://www.q3i.com/pdfs/AlcoHAWK-Precision-Datasheet.pdf</mixed-citation></ref><ref id="scirp.47036-ref46"><label>46</label><mixed-citation publication-type="other" xlink:type="simple">Bactrack S30 Product Sheet. http://www.bactrack.com/breathalyzer/images/s30-ownersmanual.pdf</mixed-citation></ref><ref id="scirp.47036-ref47"><label>47</label><mixed-citation publication-type="book" xlink:type="simple">Schmidt, E.W. and Wucherer, E.J. (2004) Hydrazine(s) vs. Nontoxic Propellants—Where Do We Stand Now? In: Wilson, A., Ed., Proceedings of the 2nd International Conference on Green Propellants for Space Propulsion (ESA SP-557), Chia Laguna (Cagliari), Sardinia, 7-8 June 2004. http://adsabs.harvard.edu/full/2004ESASP.557E...3S</mixed-citation></ref><ref id="scirp.47036-ref48"><label>48</label><mixed-citation publication-type="other" xlink:type="simple">Plemmons, D.H., Mehta, M., Clark, B.C., Kounaves, S.P., Peach Jr., L.L., Renno, N.O., Tamppari, L. and Young, S.M.M. (2008) Effects of the Phoenix Lander Descent Thruster Plume on the Martian Surface. Journal of Geophysical Research, 113, Article ID: E00A11. http://dx.doi.org/10.1029/2007JE003059</mixed-citation></ref><ref id="scirp.47036-ref49"><label>49</label><mixed-citation publication-type="other" xlink:type="simple">Taylor, L. and Oberman, S. (2006) Drunk Driving Defense. 6th Edition, Aspen, New York.</mixed-citation></ref><ref id="scirp.47036-ref50"><label>50</label><mixed-citation publication-type="other" xlink:type="simple">Mohr, G.J., Citterio, D., Demuth, C., Fehlmann, M., Jenny, L., Lohse, C., Moradian, A., Nezel, T., Rothmaier, M. and Spichiger, U.E. (1999) Reversible Chemical Reactions as the Basis for Optical Sensors Used to Detect Amines, Alcohols, and Humidity. Journal of Materials Chemistry, 9, 2259-2264. http://dx.doi.org/10.1039/a901961h</mixed-citation></ref><ref id="scirp.47036-ref51"><label>51</label><mixed-citation publication-type="other" xlink:type="simple">Federal Register (2008) National Highway Traffic Safety Administration, 16956-16960.</mixed-citation></ref><ref id="scirp.47036-ref52"><label>52</label><mixed-citation publication-type="other" xlink:type="simple">Jones, A.W. and Anderson, L. (2008) Determination of Ethanol in Breath for Legal Purposes Using a 5-Filter Infrared Analyzer: Studies on Response to Volatile Interfering Substances. Journal of Breath Research, 2, 7152-7155. http://dx.doi.org/10.1088/1752-7155/2/2/026006</mixed-citation></ref><ref id="scirp.47036-ref53"><label>53</label><mixed-citation publication-type="other" xlink:type="simple">Watterson, J.H. (2009) Assessment of Response of the Intoxilzyer 8000C to Volatiles of Forensic Relevance in Vitro, Part I: Acetone, Isopropanol, and Methanol. Journal of Analytical Toxicology, 33, 109-117. http://dx.doi.org/10.1093/jat/33.2.109</mixed-citation></ref><ref id="scirp.47036-ref54"><label>54</label><mixed-citation publication-type="other" xlink:type="simple">Conkle, J.P., Camp, B.J. and Welch, B.F. (1975) Trace Composition of Human Respiratory Gas. Archives of Environmental Health: An International Journal, 30, 290-295. http://dx.doi.org/10.1080/00039896.1975.10666702</mixed-citation></ref><ref id="scirp.47036-ref55"><label>55</label><mixed-citation publication-type="other" xlink:type="simple">Prest, L. (2011) Fundamental Investigation of Fuel Cell-Based Breath Alcohol Sensors and the Cause of Sensor Degradation in Low-Humidity Conditions. M.S. Thesis, University of Ontario Institute of Technology, Oshawa.</mixed-citation></ref><ref id="scirp.47036-ref56"><label>56</label><mixed-citation publication-type="other" xlink:type="simple">Jones, A.W. and Roessner, S. (2007) False-Positive Breath-Alcohol Test after a Ketogenic Diet. International Journal of Obesity, 31, 559-561. http://dx.doi.org/10.1038/sj.ijo.0803444</mixed-citation></ref><ref id="scirp.47036-ref57"><label>57</label><mixed-citation publication-type="other" xlink:type="simple">Loudon, G.M. (1995) Organic Chemistry. 3rd Edition, Benjamin/Cummins Publishing Company, San Francisco, 654.</mixed-citation></ref><ref id="scirp.47036-ref58"><label>58</label><mixed-citation publication-type="other" xlink:type="simple">Logan, B.K. and Distefano, S. (1998) Ethanol Content of Various Food and Soft Drinks and Their Potential for Interference with a Breath-Alcohol Test. Journal of Analytical Toxicology, 22, 181-183. http://dx.doi.org/10.1093/jat/22.3.181</mixed-citation></ref></ref-list></back></article>