<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">AJAC</journal-id><journal-title-group><journal-title>American Journal of Analytical Chemistry</journal-title></journal-title-group><issn pub-type="epub">2156-8251</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ajac.2014.55038</article-id><article-id pub-id-type="publisher-id">AJAC-44694</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Electrochemical Properties of Modified Carbon Paste with Copper Hexacyanoferrate Film on Nitric Oxide Reduction
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>iridon</surname><given-names>Berisha</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Arsim</surname><given-names>Maloku</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Eduard</surname><given-names>Andoni</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tahir</surname><given-names>Arbneshi</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Departament of Chemistry, Faculty of Mathematical and Natural Science, University of Prishtina, Prishtina, Kosovo</addr-line></aff><aff id="aff2"><addr-line>Departament of Chemistry, Faculty of Natural Sciences, University of Tirana, Tirana, Albania</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>tahir.arbneshi@uni-pr.edu(TA)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>03</day><month>04</month><year>2014</year></pub-date><volume>05</volume><issue>05</issue><fpage>308</fpage><lpage>315</lpage><history><date date-type="received"><day>26</day>	<month>February</month>	<year>2014</year></date><date date-type="rev-recd"><day>28</day>	<month>March</month>	<year>2014</year>	</date><date date-type="accepted"><day>6</day>	<month>April</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Copper hexacyanoferate film was prepared electrochemically on carbon paste electrode and was tested for detection of nitric (II) oxide in comparison with unmodified electrodes. Modified electrode could be operated under physiological conditions (pH 7.5, 0.1 M phosphate buffer), with an operating potential of ﹣400 mV (vs. Ag/AgCl) in hydrodynamic amperometry. The amperometric response of the electrode showed good linearity up to 250 μM with a detection limit (3σ) of 8.32 μM. The relative standard deviation for the repeatability of measurements for 100 μM nitric (II) oxide was 4.1% (n = 10 measurements) and the corresponding reproducibility was 14% (n = 5 electrodes). The effect of investigated interferences (nitrite and nitrate ion) was not fatal and could be eliminated using the standard addition method. The modified electrode also seems promising to detect NO in car exhaust fumes.
 
</p></abstract><kwd-group><kwd>Sensor</kwd><kwd> Nitric Oxide</kwd><kwd> Copper-Hexacyanoferrate</kwd><kwd> Electrocatalytic</kwd><kwd> Carbon Paste Electrode</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Carbon paste electrode (CPE) is a very useful material on electrochemical analysis, because of its biocompatibility for in vivo measurements [<xref ref-type="bibr" rid="scirp.44694-ref1">1</xref>] . As an electrode material it is very simple to prepare and handle, and an easy bulk modification with different mediators makes it more useful in electroanalysis for different analytes [<xref ref-type="bibr" rid="scirp.44694-ref2">2</xref>] . Using mediators on carbon paste electrodes is very important, because they may have electrocatalytic effects on analyte redox reaction. Decreasing overpotential of analyte at electrode is very important for its application. The working potential of electrode in amperometric sensors affects the deterioration of measurements on real samples, causing secondary redox reactions with sample matrix, especially nitrite and nitrate ions, which are oxidation products of nitric (II) oxide [<xref ref-type="bibr" rid="scirp.44694-ref3">3</xref>] .</p><p>The determination of NO is not a simple task because of its high reactivity; the half-life of nitric oxide in physiological conditions is around 5 seconds; therefore the required analytical methods for its spatial detection must have rapid response time [<xref ref-type="bibr" rid="scirp.44694-ref4">4</xref>] . Some of its physiological and pathophysiological effects are smooth muscle relaxation, inhibition of platelet activation, neurotransmission, immune response respectively cardiovascular diseases [<xref ref-type="bibr" rid="scirp.44694-ref5">5</xref>] etc.</p><p>The different modifiers were investigated on their ability to decrease the overpotential of nitric oxide on different electrode materials, such as nickel phtalocyanine, which has a catalytic effect on the NO oxidation [<xref ref-type="bibr" rid="scirp.44694-ref6">6</xref>] [<xref ref-type="bibr" rid="scirp.44694-ref7">7</xref>] .</p><p>Carbon paste electrode was modified in different ways, for example, to increase its catalytic effect on oxidation of nitric (II) oxide using chromium (III) oxide [<xref ref-type="bibr" rid="scirp.44694-ref8">8</xref>] , ruthenium (IV) oxide [<xref ref-type="bibr" rid="scirp.44694-ref9">9</xref>] . Also some different complex compounds were used, because of their ability to have a catalytic effect on nitric oxide overpotential such as nickel (II) hexacyanoferrate [<xref ref-type="bibr" rid="scirp.44694-ref10">10</xref>] , indium hexacyanoferrate [<xref ref-type="bibr" rid="scirp.44694-ref11">11</xref>] phenylendiamine [<xref ref-type="bibr" rid="scirp.44694-ref12">12</xref>] and poly(thionine)/Nafion [<xref ref-type="bibr" rid="scirp.44694-ref13">13</xref>] , carbon nanotube [<xref ref-type="bibr" rid="scirp.44694-ref14">14</xref>] silver nanoparticles/Hemoglobin as a biosensor recognition site [<xref ref-type="bibr" rid="scirp.44694-ref15">15</xref>] .</p><p>The copper hexacyanoferrate electrocatalytic effects were confirmed for hydrogen peroxide [<xref ref-type="bibr" rid="scirp.44694-ref16">16</xref>] , ascorbic acid [<xref ref-type="bibr" rid="scirp.44694-ref17">17</xref>] and nitrite ions [<xref ref-type="bibr" rid="scirp.44694-ref18">18</xref>] . It was also characterized for redox-mediated biosensors, as a modifier of carbon film electrodes [<xref ref-type="bibr" rid="scirp.44694-ref19">19</xref>] and it was successfully applied on carbon paste enzyme electrodes for glucose sensors [<xref ref-type="bibr" rid="scirp.44694-ref20">20</xref>] . The aim of the presented work was to improve a new modification method with copper hexacyanoferrate formed by reduction of copper on carbon paste electrode. CuHCF film was prepared using consecutive cyclic voltammetry in hexacyanoferrate ion solution of CPE-Cu film. The investigation of CuHCF film stability and electrocatalytic effect on nitric (II) oxide reduction demonstrated that carbon paste electrode modified with CuHCF works on lower potential compared to other sensors.</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Chemicals, Reagents and Solutions</title><p>All used chemicals were analytical reagent grade. Sulfanilamide, N-(1-naphtyl)-ethylene diamine, copper sulphate pentahydrate, potassium hexacyanoferrate (III), Nafion<sup>&#174;</sup> (5% m:m solution in lower aliphaic alcohols) were obtained from Sigma. Phosphate buffer solution (PBS) was prepared by mixing aqueous solutions of sodium dihydrogen phosphate (0.1 mol/L) and disodium hydrogen phosphate (0.1 mol/L) until the required pH was achieved. A nitric oxide stock solution was prepared by bubbling NO produced by the reaction of a saturated aqueous solution of sodium nitrite with 2 M sulfuric acid (Equation (1)), through a 4 M potassium hydroxide solution and finally collecting it in phosphate buffer solution (0.1 M, pH 7.5).</p><disp-formula id="scirp.44694-formula77950"><label>(1)</label><graphic position="anchor" xlink:href="htmlimages\3-2200854x\9eb7b474-a7ce-4040-bf0e-2ccefc7ffeaf.png"  xlink:type="simple"/></disp-formula><p>First, all the apparatus for NO gas production was deaerated with nitrogen gas for 30 minutes. The standard stock solution was freshly prepared before the use. The concentration of NO in the stock solution was determined using sulfanilamide and N-(1-naphtyl)-ethylenediamine as described in [<xref ref-type="bibr" rid="scirp.44694-ref21">21</xref>] . Sodium nitrite and nitrate stock solution (0.1 M) were freshly prepared before the use.</p></sec><sec id="s2_2"><title>2.2. Apparatus</title><p>The potentiostat Autolab PSTAT 10 with software GPES version 4.9 and a potentiostat PalmSens with software PSTrace were used for cyclic voltammetry and hydrodynamic amperometry. The electrochemical cell consisted of a carbon paste electrode as the working electrode, an Ag/AgCl/3M KCl reference electrode (Metrohm 6.0733.100), and a platinum wire as the counter electrode. Nitrogen was used for degassing the solutions. A magnetic stirrer provided convection of the solution. All potentials mentioned in this paper are referred to the Ag/AgCl reference electrode. The flow injection system was assembled from a potentiostat as the detector, a high performance liquid chromatographic pump (1100 ICI instruments), a sample injection valve (5020 Rheodyne, Cotati, CA, USA), and a thin layer electrochemical detector (LC 4C, BAS, West Lafayette, Indiana, USA) with a flow through cell (spacer thickness 0.19 mm; CC-5, BAS).</p><sec id="s2_2_1"><title>2.2.1. Preparation of Working Electrodes</title><p>Unmodified carbon paste was prepared by mixing 1.000 g graphite powder and 360 μL paraffin oil (Uvasol<sup>&#174;</sup>, 0.84 - 0.89 kg/L,) in an agate mortar by gently stirring with a pestle until uniformity and proper compactness was obtained.</p><p>Modified carbon paste electrode was prepared by electrodeposition of copper at −0.40 V v.s. Ag/AgCl (3 M) for 60 s, after that electrode was immersed on potassium hexacyanoferrate solution 1 mM and scanned in cyclic voltammetry for 20 cycles until no difference was mention on peak currents. The prepared film electrode of copper-hexacyanoferrate was stabilized on phosphate buffer 0.1 M pH 7.5 with 5 scans and electrode was stored on phosphate buffer.</p></sec><sec id="s2_2_2"><title>2.2.2. Procedures</title><p>Cyclic voltammograms were scanned between 900 and −700 mV with a scan rate of 50 mV/s, unless stated otherwise. Hydrodynamic amperometric measurements were made at operating potentials of −400 mV, −300 mV, −200 mV, −100 mV and 0 mV if not mentioned otherwise; NO stock solution (0.50 - 4.00 mL) was added per step.</p></sec></sec></sec><sec id="s3"><title>3. Results and Discussion</title><p>The copper electro deposition parameters are very important, because they effect on electrode response. Copper film (Cu-film) was prepared with potentiostatic method in 10 mM copper solution, using carbon paste electrode, as a working electrode. To find best time of Cu-film deposition (<xref ref-type="fig" rid="fig1">Figure 1</xref>), we compared Cu-film electrode response at −0.20V to nitric oxide for different deposition time. The deposition time of 60 sec. was chosen because better results are achieved compared to the other deposition times. The longer deposition time produces bad film compactness and stability of an electrode. The electro deposition time of 30 seconds shows higher signal value but the problems were with adding hexacyanoferrate film electrochemically. To select the potential of the electro deposition −0.70 V vs. Ag/AgCl (3M) was not conducive because it did not give a repeatable response to analyte compared to the electro deposition potential of −0.40 V. Also, the copper hexacyanoferrate film was stable after copper deposition at −0.40 V, and gives higher signal to NO.</p><sec id="s3_1"><title>3.1. Cyclic Voltammetry</title><p>Carbon paste electrode modified with Cu-film electrode was tested on cyclic voltammetry in phosphate buffer solution 0.1 M (pH 7.5). In <xref ref-type="fig" rid="fig2">Figure 2</xref>, it is shown that cyclic voltammogram of CPE-Cu film electrode can be noticed at potential of −0.20 V copper (II) reduction and around 0.0 V oxidation reaction of Cu˚ to Cu(II) and copper oxide film is produced in the electrode surface.</p><p>Cyclic voltammogram with scan rate of 5 mV/s of Cu-film electrode is shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>, where can be seen</p><p>two steps of copper (II) reduction, Cu(II) &#174; Cu(I) and Cu(I)&#174;Cu˚, peak potentials at −0.10 V respectively −0.20 V. These peaks may be shown because of complex compound formation in electrode surface with phosphate ion in solution.</p><p>Copper film electrode was covered with hexacyanoferrate using cyclic volatmmetry. The copper hexacyanoferrate film was prepared at 0.1 M potassium nitrate solution containing 1 mM potassium hexacyanoferrate. Numbers of cyclic voltammetric scans were around 20, until no significant difference was noticed of hexacyanoferrate redox peaks between the last two scans.</p><p>The reduction and oxidation peaks at potential 0.50 V and 0.80 V are peaks of redox reactions of iron hexacyanoferrate Fe<sup>III</sup>&#243;Fe<sup>II</sup>. The peak potential at −0.40 and 0.0 V corresponds to the conversion of copper from its oxidation state +2 and 0.</p><p>Based on cyclic voltammetric scans (<xref ref-type="fig" rid="fig4">Figure 4</xref>), can be concluded that copper hexacyanoferrate complex compound is formed because the oxidation and reduction peak is going to increase after every scan. Copper hexacyanoferrate (II) complex is insoluble; the produced film in the surface electrode is stable in aqua media. Copper (II/I) reduction peak at −0.40 V is increased after every scan and the concentration of oxidized copper near electrode surface is going to be higher, because its oxidized state produces complex compound with hexacyanoferrate (II). The decrease of oxidation peak intensity is attributed to metallic copper from Cu-film. This happens because the metallic form in the surface electrode is going to decrease after every scan, because the copper exists in oxidized form as copper (II) complex with hexacyanoferrate.</p><p>Carbon paste electrode modified with copper hexacyanoferrate film was tested on 0.1 M phosphate buffer solution pH 7.5 for its response to nitric (II) oxide (<xref ref-type="fig" rid="fig5">Figure 5</xref>). After the addition of nitric (II) oxide, cathodic current is increased near reduction peak of copper because of the electrocatalytic effects of copper (II) hexacyanoferrate. The suggested reaction mechanism (<xref ref-type="fig" rid="fig6">Figure 6</xref>) assumes the chemical oxidation of copper hexacyanoferrate by NO and produce of nitrosyl ciano complex compound which returns electrochemically to the reduced form, at the electrode surface. At positive potential above 0.75 V the oxidation current is increased because of NO oxidation at electrode.</p></sec><sec id="s3_2"><title>3.2. Hydrodynamic Amperometry</title><p>The modified electrode with copper hexacyanoferrate film was tested for its response to different concentration of nitric oxide solutions. The modified electrode shows linearity up to concentration 250 &#181;M, with sensitivity 5.696 nA/&#181;M and correlation factor 0.994 (<xref ref-type="fig" rid="fig7">Figure 7</xref>).</p><p>The detection limit (3σ) calculated from standard deviation in hydrodynamic amperometry for 43.7 &#181;M solution of NO was 8.32 &#181;M (SD = 15.8, average 219.4 nA).</p><p>The main interferent compounds may come from nitrite and nitrate ions, which are also the reaction products of NO oxidation, and other compounds that are present in real samples. To avoid interferences we used sulfonil polyfluorotetraethylene (Nafion<sup>&#174;</sup>) membrane. This anionic membrane contains negatively charged sulfonyl</p><p>groups which prevent penetration of negatively charged ions to electrode surface. The neutralized Nafion solution was diluted with alcohol, and the electrode surface was covered with 10 &#181;L.</p><p>Based on the results shown in <xref ref-type="fig" rid="fig8">Figure 8</xref>, the electrode does not show measurable signal for nitrite and nitrate ions except on 0 V the signal intensity was −1 nA and −28 nA for <inline-formula><inline-graphic xlink:href="tmlimages\3-2200854x\549f29e2-c80a-4352-bfc8-88ab7fad18f3.png" xlink:type="simple"/></inline-formula> respectively<inline-formula><inline-graphic xlink:href="tmlimages\3-2200854x\b711a1e9-143c-4630-836f-872bfcc0e255.png" xlink:type="simple"/></inline-formula>. As expected, the signal for nitric (II) oxide solution is decreased because of covered surface with polyfluorotetraethylene memane. Nafion membrane is penetrable of NO molecule, but it covers physically the electroactive sites of electrode surface.</p></sec></sec><sec id="s4"><title>4. Conclusion</title><p>Carbon paste electrode modified with copper hexacyanoferrate as an electrocatalytic mediator exhibit improved performance for the determination of nitric oxide, compared to unmodified electrodes, because the modifier lowers the over-potential and increases the sensitivity for the electrochemical reduction of the analyte. The reaction mechanism involves the reaction of copper Cu˚(I/II) and iron of hexacyanoferrate ion Fe(II/III). The suggested reaction mechanism assumes the chemical oxidation of copper Cu˚<inline-formula><inline-graphic xlink:href="tmlimages\3-2200854x\72bc2258-55dc-4fa2-911a-6159b7958923.png" xlink:type="simple"/></inline-formula>Cu(I/II) or iron Fe(II)<inline-formula><inline-graphic xlink:href="tmlimages\3-2200854x\e2667822-8df3-4026-8530-2e8151dda3c7.png" xlink:type="simple"/></inline-formula> Fe(III) by NO producing nytrosyl complex compound. This nytrosyl ciano complex is electrochemically reduced at electrode. The modified electrode has a good stability and high sensitivity which can be exploited for the determination of nitric oxide in hydrodynamic amperometry. The new chemical sensor also seems promising to detect NO in car exhaust fumes.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.44694-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Svancara, I., Kalcher, K., Walcarius, A. and Vytras, K. (2012). Electroanalysis with Carbon Paste Electrodes. CRC Press, 163.</mixed-citation></ref><ref id="scirp.44694-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Beyene, N.W., Kotzian, P., Schachl, K., Alemuc, H., Turku&amp;scaron;ic, E., Copra, A., Moderegger, H., &amp;Scaron;vancara, I., Vytras K. and Kalcher, K. (2004) (Bio)Sensors Based on Manganese Dioxide-Modified Carbon Substrates: Retrospections. Further Improvements and Applications. Talanta, 64, 1151-1159. http://dx.doi.org/10.1016/j.talanta.2004.03.068</mixed-citation></ref><ref id="scirp.44694-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Bedioui, F. and Griveau, S. (2013) Electrochemical Detection of Nitric Oxide: Assessment of Twenty Years of Strategies. Electroanalysis, 25, 587-600. http://dx.doi.org/10.1002/elan.201200306</mixed-citation></ref><ref id="scirp.44694-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Hetrick, E.M. and Schoenfisch, M.H. (2009) Analytical Chemistry of Nitric Oxide. Annual Review of Analytical Chemistry, 2, 409-433. http://dx.doi.org/10.1146/annurev-anchem-060908-155146</mixed-citation></ref><ref id="scirp.44694-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Saldanha, C., Almeida, J.P.L. and Silva-Herdade, A.S. (2014) Application of a Nitric Oxide Sensor in Biomedicine. Biosensors, 4, 1-17. http://dx.doi.org/10.3390/bios4010001</mixed-citation></ref><ref id="scirp.44694-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Trevin, S., Bedioui, F. and Devynck, J. (1996) Electrochemical and Spectrophotometric Study of the Behavior of Electropolymerized Nickel Porphyrin Films in the Determination of Nitric Oxide in Solucion. Talanta, 43, 303-311. http://dx.doi.org/10.1016/0039-9140(95)01752-6</mixed-citation></ref><ref id="scirp.44694-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Allen, B.W., Piantadosi, C.A. and Coury, L.A. (2000) Electrode Materials for Nitric Oxide Detection. Nitric Oxide: Biology and Chemistry, 4, 75-84. http://dx.doi.org/10.1006/niox.2000.0273</mixed-citation></ref><ref id="scirp.44694-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Berisha, L.S., Kalcher, K., Maloku, A., Andoni, E. and Arbneshi, T. (2013) Electrocatalytic Oxidation of Nitric Oxide at Carbon Paste Electrode Modified with Chromium (III) Oxide. Journal of Advances in Chemistry, 5, 792-799. http://cirworld.com/index.php/jac/article/view/3183</mixed-citation></ref><ref id="scirp.44694-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Pubudu, W. and Peiris, M. (2009) New Generation of Electrochemical Sensors for Nitric Oxide: Ruthenium/Carbon-Based Nanostructures and Colloids as Electrocatalytic Platforms. Ph.D. Dissertation, Cleveland State University. http://rave.ohiolink.edu/etdc/view?acc_num=csu1283257971</mixed-citation></ref><ref id="scirp.44694-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Krylov, A.V. and Lisdat, F. (2007) Nickel Hexacyanoferrate-Based Sensor Electrode for the Detection of Nitric Oxide at Low Potentials. Electroanalysis, 19, 23-29. http://dx.doi.org/10.1002/elan.200603668.</mixed-citation></ref><ref id="scirp.44694-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Casero, E., Pariente, F. and Lorenzo, E. (2003) Electrocatalytic Oxidation of Nitric Oxide at indium hexacyanoferrate Film-Modified Electrodes. Analytical and Bioanalytical Chemistry, 375, 294-299. http://dx.doi.org/10.1007/s00216-002-1650-y</mixed-citation></ref><ref id="scirp.44694-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Friedemann, M.N., Robinson, S.W. and Gerhardt, G.A. (1996) o-Phenylenediamine-Modified Carbon Fiber Electrodes for the Detection of Nitric Oxide. Analytical Chemistry, 68, 2621-2628. http://dx.doi.org/10.1021/ac960093w</mixed-citation></ref><ref id="scirp.44694-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Chen, X., XIe, P., Tian, Q. and Hu, S. (2006) Amperometric Nitric Oxide Sensor Based on Poly (Thionine)/Nafion-Mo- dified Electrode and Its Application in Monitorin Nitric Oxide Release from Rat Kidney. Analytical Letters, 39, 1321-1332. http://dx.doi.org/10.1080/00032710600666438</mixed-citation></ref><ref id="scirp.44694-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Wu, F.H., Zhao, G.C. and Wei, X.W. (2002) Electrocatalytic Oxidation of Nitric Oxide at Multi-Walled Carbon Nanotubes Modified Electrode. Electrochemistry Communications, 4, 690-694. http://dx.doi.org/10.1016/S1388-2481(02)00435-6</mixed-citation></ref><ref id="scirp.44694-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Gan, X., Liu, T., Hu, X. and Li, G. (2004) An Electrochemical Biosensor for Nitric Oxide Based on Silver Nanoparticles and Hemoglobin. Analytical Sciences, 20, 1271-1275. http://dx.doi.org/10.2116/analsci.20.1271</mixed-citation></ref><ref id="scirp.44694-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Garjonyte, R. and Malinauskas, A. (1999) Operational Stability of Amperometric Hydrogen Peroxide Sensors, Based on Ferrous and Cooper Hexacyanoferrates. Sensors and Actuators B, 56, 92-97. http://dx.doi.org/10.1016/S0925-4005(99)00161-6</mixed-citation></ref><ref id="scirp.44694-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Pauliukaite, R., Ghica, M.E. and Brett, C.M.A. (2005) A New, Improved Sensor for Ascorbate Determination at Copper Hexacyanoferrate Modified Carbon Film Electrodes. Analytical and Bioanalytical Chemistry, 381, 972-978. http://dx.doi.org/10.1007/s00216-004-2958-6</mixed-citation></ref><ref id="scirp.44694-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Ojani, R., Raoof, J.B. and Norouzi, B. (2008) Cu(II) Hexacyanoferrate (III) Modified Carbon Paste Electrode; Application for Electrocatalytic Detection of Nitrite. Electroanalysis, 20, 1996-2002. http://dx.doi.org/10.1002/elan.200804278</mixed-citation></ref><ref id="scirp.44694-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Pauliukaite, R., Florescu, M. and Brett, C.M.A. (2005) Characterization of Cobalt- and Copper Hexacyanoferrate-Modified Carbon Film Electrodes for Redox-Mediated Biosensors. Journal of Solid State Electrochemistry, 9, 354-362. http://dx.doi.org/10.1007/s10008-004-0632-8</mixed-citation></ref><ref id="scirp.44694-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Wang, J., Zhang, X. and Prakash, M. (1999) Glucose Microsensors Based on Carbon Paste Enzyme Electrodes Modified with Cupric Hexacyanoferrate. Analytica Chimica Acta, 395, 11-16. http://dx.doi.org/10.1016/S0003-2670(99)00306-2</mixed-citation></ref><ref id="scirp.44694-ref21"><label>21</label><mixed-citation publication-type="other" xlink:type="simple">Nims, R.W., Darbyshire, J.F., Saavedra, J.E., Christodoulou, D., Hanbauer, I., Cox, G.W., Grisham, M.B., Laval, J., Cook, J.A., Krishna, M.C. and Wink, D.A. (1995) Colorimetric Methods for the Determination of Nitric Oxide Concentration in Neutral Aqueous Solutions. Methods (A Companion to Methods Enzymology), 7, 48-54. http://dx.doi.org/10.1006/meth.1995.1007</mixed-citation></ref></ref-list></back></article>