<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JEP</journal-id><journal-title-group><journal-title>Journal of Environmental Protection</journal-title></journal-title-group><issn pub-type="epub">2152-2197</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jep.2014.54035</article-id><article-id pub-id-type="publisher-id">JEP-44128</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Earth&amp;Environmental Sciences</subject></subj-group></article-categories><title-group><article-title>
 
 
  Acoustical Design of an Electrical Emergency Plant Using Sea Method
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>vgeny</surname><given-names>Podzharov</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>José</surname><given-names>F. de la Mora Gálvez</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jesus</surname><given-names>A. Alvarez Sanchez</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Superior School of Engineering Prolongacion Calz, University of Panamericana, Circunv. Pte 49, Guadalajara, México</addr-line></aff><aff id="aff1"><addr-line>Electromechanical Engineering Department, University of Guadalajara, Puerta 10, Guadalajara, México</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>epodzhar@up.edu.mx(VP)</email>;<email>fmora@up.edu.mx(JFDLMG)</email>;<email>jaas2001@yahoo.es(JAAS)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>18</day><month>03</month><year>2014</year></pub-date><volume>05</volume><issue>04</issue><fpage>327</fpage><lpage>332</lpage><history><date date-type="received"><day>12</day>	<month>January</month>	<year>2014</year></date><date date-type="rev-recd"><day>13</day>	<month>February</month>	<year>2014</year>	</date><date date-type="accepted"><day>11</day>	<month>March</month>	<year>2014</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   The statistical energy analysis (SEA) was used in the acoustical design of an electrical emergency plant to reduce the outdoor noise level. In the past, when the plant was working, a high annoying noise was heard all over the university camp. At a first glance the principal ways of noise propagation were the open door of the plant which was used for the suction of fresh air and a vast hole in the ceiling which was used for gases outlet. Also, a spectral analysis of the noise inside the plant showed that the dominant frequencies of the noise were in the range of 120 - 270 Hz. This frequency range is near the critical frequency of the brick walls that is 129 Hz, at which the walls are transparent for noise. A two-block diagram is used for the statistical energy analysis. Two ways of sound transmission are considered through the inlet and outlet holes and through the walls and ceiling. This analysis shows that the exclusion of holes wouldn’t be sufficient to reduce noise to an acceptable level in a low frequency range but increase the noise absorption by the wall coating material. The transmission loss is calculated for different wall coatings and hole areas. A layer of fiberglass of two-inch width is selected to increase the wall absorption coefficient. Special silencers are designed and put at the suction of air and at the outlet of engine gases to reduce the noise propagation through the holes. The noise measurement shows that the noise level is considerably reduced after implementation of these measures. The reduction of noise is 7 - 8 dB (A), 19 dB (A) and 23 dB (A), inside the plant, 10 m and 15 m away from the plant, respectively. 
 
</p></abstract><kwd-group><kwd>Noise Reduction of an Elictric Plant; Statistical Energy Analysis; Transmission Loss; Spectral Analysis; Absoption of Noise</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The noise contamination in the cities is an important problem nowadays as the cities become more populated and there are more vehicles on the streets. One part of the problem is the noise in studying and working areas as well as in the residential areas.</p><p>In the University of Panamericana in Guadalajara, Mexico, there is an electrical emergency plant which supplies electricity for the campus during the electricity cut-offs in the summer during the rainy season. The plant has a diesel engine and electric generator which are installed inside a small building. This engine was producing a very loud noise which was heard all over the university campus and was the cause of many complaints by students and professors.</p></sec><sec id="s2"><title>2. Noise Measurements and Its Analysis</title><p>The results of the noise measurements inside and outside of the plant are shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. The noise level inside the plant is very high (112 dBA). It decreases 13 dBA passing the open door of the plant. Then it decreases slowly till 72 dBA at 25 m from the source being still high. The measurements in the offices and the class rooms of the building nearer to the plant showed noise levels from 59 dBA to 69 dBA which are all beyond the permissible noise level.</p><p>The noise spectrum inside the plant shows (<xref ref-type="fig" rid="fig2">Figure 2</xref>) that the majority of noise’s components are in low fre-</p><p>quency range near 200 Hz; meanwhile there are also high level components in the middle frequency range up to 1200 Hz and in higher frequencies.</p></sec><sec id="s3"><title>3. Analysis of the Plant Acoustical System Using Sea Method</title><p>The principle ways of noise propagation must be studied to reduce effectively the noise level. The noise radiated by the machine towards the internal acoustical space inside the plant goes out to the external acoustical space by three ways: 1) through the entrance door and the exhaust hole in the ceiling, 2) through the walls, 3) through the foundation. The third way can be considered insignificant because the machine is properly vibroisolated from the foundation.</p><p>To realize the acoustical analysis of the plant by the SEA method an acoustical model in <xref ref-type="fig" rid="fig3">Figure 3</xref> can be used.</p><p>Where E1—acoustical energy of the internal acoustical space, J E2—acoustical energy of the external acoustical space, J W in—acoustical power introduced by the machine, W</p><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\50f5e995-15ca-464a-a49e-4bda44dfd5e6.png" xlink:type="simple"/></inline-formula>—acoustical power dissipated in the element i of the model, which can be determined using the following equation [<xref ref-type="bibr" rid="scirp.44128-ref1">1</xref>]</p><disp-formula id="scirp.44128-formula18580"><label>, (1)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\d157bebb-a184-4c62-aec3-bcc2f499d000.png"  xlink:type="simple"/></disp-formula><p>Where</p><p>η<sub>i</sub>—loss factor of element iω = 2πf—angular frequency, rad/s f—frequency, Hz.</p><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\daf38db8-f8bf-400c-b238-7df650d127e5.png" xlink:type="simple"/></inline-formula>—acoustical power transmitted through the walls and ceiling, W</p><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\aa2e3479-8ed4-4af1-bde7-3b17ac8f8d8b.png" xlink:type="simple"/></inline-formula>—acoustical power transmitted through the door and the air duct in the ceiling, W According to [<xref ref-type="bibr" rid="scirp.44128-ref1">1</xref>] [<xref ref-type="bibr" rid="scirp.44128-ref2">2</xref>] the equation of energy balance can be written as follows</p><p><img src="htmlimages\10-6702220x\7e2fee71-661c-40d5-867b-adad4cf82e7c.png" /></p><disp-formula id="scirp.44128-formula18581"><label>. (2)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\e419df55-14c0-4de2-8b93-5ec349f7c9a3.png"  xlink:type="simple"/></disp-formula><p>Here</p><disp-formula id="scirp.44128-formula18582"><label>(3)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\8df19204-be79-4e74-a649-af3010672798.png"  xlink:type="simple"/></disp-formula><p>Where</p><p>η<sub>ij</sub>—transmission loss factor between elements i and j.</p><p>Substituting Equation (3) into Equation (2) and then into Equation (1) and considering that acoustical energy transmission is insignificant in the inverse direction, as<inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\a4fbe218-1ab0-4c0c-ad04-75c74c7a8fe1.png" xlink:type="simple"/></inline-formula>, the equation of energy balance can be obtained in the following form</p><disp-formula id="scirp.44128-formula18583"><label>, (4)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\782c233a-db4f-4d66-a587-83b3a523f084.png"  xlink:type="simple"/></disp-formula><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\4bf5c7cf-8a7f-46f4-9621-8469365ccf9d.png" xlink:type="simple"/></inline-formula>.</p><p>Now, dividing the first equation of (4) by the second, we have</p><disp-formula id="scirp.44128-formula18584"><label>(5)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\5cbbe323-cad7-4c3f-995e-9bc7fc40e572.png"  xlink:type="simple"/></disp-formula><p>The acoustical energy transmitted through the holes must be proportional to the relation</p><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\dda0b47f-87b5-4842-99ea-e29969307a9b.png" xlink:type="simple"/></inline-formula>, where</p><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\bcef28f5-8568-4af7-b30d-0648f0313f7f.png" xlink:type="simple"/></inline-formula>—the total area of the holes,</p><p><inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\b34da339-666a-44c6-81f0-a907be8d5f57.png" xlink:type="simple"/></inline-formula>—the total area of the walls and the ceiling.</p><p>So the coefficient <inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\a4a3b3b5-17d6-45c4-b70e-a1e336175257.png" xlink:type="simple"/></inline-formula> can be found from the equation</p><disp-formula id="scirp.44128-formula18585"><label>(6)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\53b659cc-cc9f-4518-9141-0006fd4b526c.png"  xlink:type="simple"/></disp-formula><p>When<inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\2416819c-4835-4c74-902e-a8ff9ddcc2bc.png" xlink:type="simple"/></inline-formula>, Equation (6) can be transformed into the equation</p><disp-formula id="scirp.44128-formula18586"><label>(7)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\f51ad935-c001-43e3-828c-b07829d09831.png"  xlink:type="simple"/></disp-formula><p>Substituting Equation (7) in Equation (5), we have</p><disp-formula id="scirp.44128-formula18587"><label>(8)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\4c44d273-7845-4dda-af4d-527da4c55943.png"  xlink:type="simple"/></disp-formula><p>The attenuation of machine noise by the walls and the ceiling can be found as</p><disp-formula id="scirp.44128-formula18588"><label>(9)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\8dd5ea78-9081-4b3d-adc4-4d84bd497b8c.png"  xlink:type="simple"/></disp-formula><p>where</p><p>η<sub>1</sub>—loss factor of the absorption of the noise by the walls, the ceiling and the floor, it can be accepted equal to absorption coefficients of materials [<xref ref-type="bibr" rid="scirp.44128-ref3">3</xref>] .</p><p>According to [<xref ref-type="bibr" rid="scirp.44128-ref1">1</xref>]</p><disp-formula id="scirp.44128-formula18589"><label>, (10)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\8ac7828c-135b-4c71-9445-b33d490a95c4.png"  xlink:type="simple"/></disp-formula><p>where c—sound velocity in airτ = 10<sup>−TL/10</sup>—Transmission loss factorTL—transmission lossV1—volume of the internal acoustical space, m<sup>3</sup></p><p>f—sound frequency, Hz.</p><p>The transmission loss depends on the sound frequency and the critical frequency f<sub>c</sub> of the walls [<xref ref-type="bibr" rid="scirp.44128-ref2">2</xref>] ,</p><disp-formula id="scirp.44128-formula18590"><label>, (11)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\85ffba96-01fe-4fd7-aadb-bf841627d7aa.png"  xlink:type="simple"/></disp-formula><p>Where c<sub>L</sub>—velocity of longitudinal waves in the barrier (walls, ceiling), m/s t—barrier width, m.</p><p>For the walls and ceiling of bricks with t = 0.15 m and f<sub>c</sub> = 129 Hz, c<sub>L</sub> = 3400 m/s, c = 344 m/s.</p><p>When f &lt; f<sub>c</sub> the mass law actuates and</p><p><img src="htmlimages\10-6702220x\93251d2f-1598-4e29-bbd0-4076db29aa9c.png" /></p><p>when <inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\ad786806-a6e8-4c3f-a66c-8c97fd1208a6.png" xlink:type="simple"/></inline-formula> <inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\91dfccf9-7769-4ffb-92bb-662a8cb80c9c.png" xlink:type="simple"/></inline-formula></p><p>when <inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\df777f0d-6810-4beb-a524-3d88f4e05835.png" xlink:type="simple"/></inline-formula>                  <inline-formula><inline-graphic xlink:href="tmlimages\10-6702220x\97b0433d-ece0-4562-ba63-4c5146075b14.png" xlink:type="simple"/></inline-formula>                   (12)</p><p>where ρ—air density, kg/m<sup>3</sup></p><p>ρ<sub>S</sub>—unit area density, kg/m<sup>2</sup></p><p>η<sub>W</sub>—walls dissipation coefficient ( for bricks η<sub>W</sub> = 0.01).</p><p>The total area of the walls and ceiling of the plant is A = 110.5 m<sup>2</sup>, the volume V<sub>1</sub> = 110.05 m<sup>3</sup>. The area of the holes was estimated as A = 3 m<sup>2</sup>.</p><p>The attenuation of sound is calculated using Equations (10) - (14). The results of these calculations are presented in <xref ref-type="fig" rid="fig4">Figure 4</xref>. The curve 1 corresponds to the initial conditions. It gives only 15 dB except the zone of critical frequency where the attenuation falls till 5 dB. This almost coincides with the results of noise measurements (<xref ref-type="fig" rid="fig1">Figure 1</xref>). The reduction of the area of holes up to 1 m increases the attenuation by 5 dB except in the critical frequency (curve 2). For further increase of the attenuation, two silencers for the suction and exhaust holes were designed and fabricated. The silencers are of absorbing type and were designed using fiberglass and perforated steel sheets.</p><p>The attenuation of sound in silencers can be estimated [<xref ref-type="bibr" rid="scirp.44128-ref4">4</xref>] [<xref ref-type="bibr" rid="scirp.44128-ref5">5</xref>] using this equation:</p><disp-formula id="scirp.44128-formula18591"><label>(13)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\9c9a07da-d417-4899-9de5-20eccc3fa31a.png"  xlink:type="simple"/></disp-formula><p>where l—longitude of silencer, m</p><p>α—absorption coefficientP—interior perimeter of the duct, m S—interior transverse area of the duct, m<sup>2</sup>.</p><p>The absolute value of this sound absorption is</p><disp-formula id="scirp.44128-formula18592"><label>. (14)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\119fb7f8-2dee-483b-8893-0c7e44450bbd.png"  xlink:type="simple"/></disp-formula><p>Taking into account the silencers attenuation, Equation (9) will transform in the following</p><disp-formula id="scirp.44128-formula18593"><label>(15)</label><graphic position="anchor" xlink:href="htmlimages\10-6702220x\1bcb9525-30ee-473c-a7a6-0a8f6630eac5.png"  xlink:type="simple"/></disp-formula><p>Using Equation (17) curve 3 and 4 in <xref ref-type="fig" rid="fig4">Figure 4</xref> is calculated. As we see from <xref ref-type="fig" rid="fig4">Figure 4</xref> the introduction of silencers reduces the noise very much except in the critical frequency. For reducing the noise in the critical frequency and overall, the walls and the ceiling are covered with fiberglass of 2 inch thick (curve 4 in <xref ref-type="fig" rid="fig4">Figure 4</xref>).</p><p>In <xref ref-type="fig" rid="fig1">Figure 1</xref> the effect of this vibroacoustical design in the reduction of noise level of the plant is presented. It can be seen that the noise level is reduced by 23 dBA at the distance of 15 m away from the source. Now the noise of the plant in the working area is so low that it is practically not heard.</p></sec><sec id="s4"><title>4. Conclusions</title><p>1) The noise measurements of the plant in the university campus show that the noise level exceeds the permissible levels in the offices and classrooms.</p><p>2) An analysis of the acoustical system of the plant using the SEA method shows that the walls and the ceiling don’t have enough transmission loss because of vast holes at the suction of air and at the exhaust.</p><p>3) The reduction of the hole areas from 3 m<sup>2</sup> to 1 m<sup>2</sup> does not give a sufficient reduction of the noise.</p><p>4) By using fiberglass coatings for the walls and ceiling and especially designed silencers, a sufficient reduction of noise level (23 dBA at the distance of 15 m from the source) is achieved.</p></sec></body><back><ref-list><title>References</title><ref id="scirp.44128-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Lion, R. (1975) Statistical Energy Analysis. Theory and Applications. The MIT Press, Cambridge and London.</mixed-citation></ref><ref id="scirp.44128-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Leo, L. and Beranek, I.L.V. (1992) Noise and Vibration Control Engineering. Principles and Application. Wiley &amp; Sons, Inc., New York.</mixed-citation></ref><ref id="scirp.44128-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Cyril, M.H. (1995) Manual de Medidas Acústicas y Control del Ruido. Tercera Edición. McGraw-Hill, New York.</mixed-citation></ref><ref id="scirp.44128-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Faulkner, L.L. (1975) Handbook of Industrial Noise Control. Industrial Press Inc., South Norwalk.</mixed-citation></ref><ref id="scirp.44128-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Lewis, H.B. and Douglas, H.B. (1994) Industrial Noise Control. Fundamentals and Applications. 2nd Edition. Marcel Dekker, Inc., New York.</mixed-citation></ref></ref-list></back></article>