<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SNL</journal-id><journal-title-group><journal-title>Soft Nanoscience Letters</journal-title></journal-title-group><issn pub-type="epub">2160-0600</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/snl.2013.34A013</article-id><article-id pub-id-type="publisher-id">SNL-40526</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Non-Enzymatic Glucose Sensor Based on the Novel Flower Like Morphology of Nickel Oxide
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>.</surname><given-names>H. Ibupoto</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>K.</surname><given-names>Khun</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>V.</surname><given-names>Beni</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>M.</surname><given-names>Willander</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Department of Physics, Chemistry, and Biology (IFM), Link?ping University, Link?ping, Sweden. </addr-line></aff><aff id="aff1"><addr-line>Division of Physical Electronics and Nanotechnology, Department of Science and Technology, Link?ping University, Campus Norrk?ping, Norrk?ping, Sweden; </addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>sukantakutripathy@yahoo.co.in(.HI)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>04</day><month>12</month><year>2013</year></pub-date><volume>03</volume><issue>04</issue><fpage>46</fpage><lpage>50</lpage><history><date date-type="received"><day>October</day>	<month>1st,</month>	<year>2013</year></date><date date-type="rev-recd"><day>November</day>	<month>13th,</month>	<year>2013</year>	</date><date date-type="accepted"><day>November</day>	<month>20th,</month>	<year>2013</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this study, novel nickel oxide (NiO) flowers like nanostructures were fabricated onto gold coated glass substrate by hydrothermal method using high alkaline pH medium. The structural study of nickel oxide nanostructures was performed by scanning electron microscopy (SEM) and X-ray differaction (XRD) techniques. Nickel oxide nanostructures are highly dense, uniform and possess good crystalline quality. The so prepared structures were investigated for their electrochemical properties by cyclic voltammetry and amperometric techniques. The nickel oxide flower like morphology has shown good electrochemical performances for the oxidation of glucose. The presented sensing material was able to detected glucose in a wide range of concentration of 0.001 mM to 8 mM with a high sensitivity (123
   
  μmA/mM) and regression coefficient of 0.99. Moreover, the NiO nanostructures based sensor is highly reproducible, stable, exhibiting a fast response time and selective in the response. All the obtained results indicate the potential use of this material in the development of enzyme free sensors for the detection of glucose.
  
 
</p></abstract><kwd-group><kwd>Nickel Oxide; Non-Enzymatic Sensor; Glucose; Selective; Stable</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Due to increase in the number of diabetes patients, the accurate and sensitive detection of glucose has drawn the attention of researchers towards the simple and cheap fabrication of glucose sensors [<xref ref-type="bibr" rid="scirp.40526-ref1">1</xref>]. Updike and Hicks for the first time developed glucose oxidase immobilized amperometric glucose sensor [<xref ref-type="bibr" rid="scirp.40526-ref2">2</xref>]. Afterwards electrochemical biosensors, using glucose oxidase as biorecognition material, have been largely studied and examined [3-5]. Although the glucose sensors using glucose oxidase have several merits such as high sensitivity and selectivity, however the catalytic activity of glucose oxidase is easily reduced by variations in pH, temperature, humidity and by the interference offered by other substances. Recently, non-enzymatic glucose sensors are becoming more popular due to their acceptable reproducibility, stability, low costs and simplicity. Several metal oxides nanostructures based non-enzymatic glucose sensors have been reported such as NiO [6-8], MnO<sub>2</sub> [<xref ref-type="bibr" rid="scirp.40526-ref9">9</xref>], Co<sub>3</sub>O<sub>4</sub> [<xref ref-type="bibr" rid="scirp.40526-ref10">10</xref>], CuO [<xref ref-type="bibr" rid="scirp.40526-ref11">11</xref>]. Still more work is required in the fabrication of non-enzymatic glucose sensors for improving their sensitivity and selectivity.</p><p>The nickel oxide (NiO) nanomaterial with homogenous size and well defined dispersion is highly demanded for the various applications such as designing ceramic, magnetic, electrochromic and heterogeneous catalytic materials [<xref ref-type="bibr" rid="scirp.40526-ref12">12</xref>]. Different synthetic routes have been proposed for the fabrication of NiO nanomaterial including sol-gel [<xref ref-type="bibr" rid="scirp.40526-ref13">13</xref>], surfactant mediated synthesis [<xref ref-type="bibr" rid="scirp.40526-ref14">14</xref>], thermal decomposition [<xref ref-type="bibr" rid="scirp.40526-ref15">15</xref>] and polymer matrix assisted preparation [<xref ref-type="bibr" rid="scirp.40526-ref16">16</xref>]. Some of the above mentioned growth routes are facing problems in the uniform size and well dispersion of NiO nanoparticles.</p><p>The hydrothermal method for the growth of various nanomaterials is also known as super-heated hydrothermal solution based method. Hydrothermal method is considered environmentally benign and it can be used for the growth of various nanomaterials even in strong solvents in the closed system. Moreover, hydrothermal method is inexpensive, simple and yields high purity of desired product, thus it is a highly suitable method from industrial point of view. To date, several methods have been proposed for the synthesis of NiO nanoparticles and nanorods, but few reports have been published for the preparation of porous nanosheets [17,18]. Nickel oxide is the material which can easily be grown by hydrothermal method with high yield on the substrate.</p><p>In this work, novel NiO nanoflowers have been synthesized by the hydrothermal method and successfully applied for the development of enzyme free glucose sensor by cyclic voltammetry and amperometric measurements. The sensor electrode is very stable, reproducible, repeatable, sensitive and selective.</p></sec><sec id="s2"><title>2. Experimental Section</title><sec id="s2_1"><title>2.1. Used Materials</title><p>Nickel nitrate hexahydrate, hexamethylenetetramine, 25% ammonia, nitric acid d-glucose, ascorbic acid, uric acid and dopamine were purchased from Sigma Aldrich Sweden. All other chemical used were of analytical standard.</p></sec><sec id="s2_2"><title>2.2. The Synthesis of NiO Nanostructures on the Gold Coated Glass Substrate</title><p>The coating of gold layer on the glass substrate was done according to our previous work [<xref ref-type="bibr" rid="scirp.40526-ref19">19</xref>]. The synthesis of NiO was carried out in two steps. Firstly nickel hydroxide Ni(OH)<sub>2</sub> was grown the gold coated glass substrate by hydrothermal growth approach using the equimolar 0.1 M solution of nickel hexahydrate and hexamethylenetetramine. Nickel hydroxide was grown in alkaline medium of pH 11 and the pH of growth solution was adjusted by using few drops f 25% ammonia and 0.1 M nitric acid. The gold electrodes were cleaned in the isopropanol in the ultrasonic bath for 10 - 15 minutes, then were washed with the deionized water and dried with the nitrogen gas at room temperature. Afterwards, the gold electrodes were affixed in the Teflon sample holder and vertically dipped in the growth solution and left in the preheated oven at 98˚C for 4 - 6 hours. Secondly, after the synthesis of nickel hydroxide the conversion of nickel hydroxide into NiO was performed by annealing the nickel hydroxide grown samples at 450˚C for 2 - 3 hours.</p><p>Scanning electron microscopy and X-ray differaction techniques were used for the morphological and crystal studies of prepared NiO nanostructures respectively. The prepared NiO nanostructures were used for the development of enzyme free glucose sensor and the electrochemical measurements were performed by the potentiostat/galvanostat FRA 2 &#181; Autolab type (III) model. The electrochemical cell used in the proposed work was a three electrode system, NiO nanostructures were used as the working electrode, platinum wire as counter electrode and silver-silver chloride wire as reference electrode. The glucose solution was prepared in the deionized water and all measurements were carried out in 0.1 M NaOH solution with successive addition of glucose solution.</p></sec></sec><sec id="s3"><title>3. Results and Discussions</title><sec id="s3_1"><title>3.1. The Structural Study of as Grown NiO Nanostructures on the Gold Coated Glass Substrate</title><p>The morphology of as prepared NiO nanostructures was investigated by using the scanning electron microscopy and the obtained nanostructures are shown in <xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>. It can be seen from the <xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>(a) that NiO nanostructures are composed of nanoflowers that are synthesized in alkaline pH medium [<xref ref-type="bibr" rid="scirp.40526-ref11">11</xref>]. The nanostructures resemble a rose flower like morphology with average thickness of 10 - 20 nm. <xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>(b) shows the high magnification image of nanoflowers and it can be observed that nanostructures are highly dense, uniform and covered the whole substrate area. Energy dispersive X-ray analysis has shown the pure composition of NiO nanostructures presented in this study as shown in <xref ref-type="fig" rid="fig1"><xref ref-type="fig" rid="fig">Figure </xref>1</xref>(c). For the analysis of crystalline array of NiO nanostructures, X-ray differaction technique was used and the measured XRD spectrum is shown in <xref ref-type="fig" rid="fig2"><xref ref-type="fig" rid="fig">Figure </xref>2</xref>. The observed crystal planes include (012), (110) and (113) which are the characteristic peaks of NiO and supported by JCPDS card no: (47-1049). One of the NiO peak is merged with the very intense peak of gold due gold coating on the glass substrate.</p></sec><sec id="s3_2"><title>3.2. The Cyclic Voltametric and Amperometric Measurement of the Proposed Enzyme Free Glucose Sensor Using NiO Nanostructures</title><p>The electro catalytic activity of NiO flower-like nanostructured electrode taword the oxidation of glucose was studied by cyclic voltammetry (CV). <xref ref-type="fig" rid="fig3"><xref ref-type="fig" rid="fig">Figure </xref>3</xref> shows the CV response of the bare gold electrode and NiO grown gold electrode in the different concentrations of glucose in 0.10 M NaOH solution at the scan rate of 10 mV/s. As it can be seen from this <xref ref-type="fig" rid="fig">Figure </xref>a clear oxidation wave is recorded; this wave is increasing wit the concentration of the glucose. Likewise, the oxidative potential was slightly shifted positively. <xref ref-type="fig" rid="fig">Figure </xref>4 shows the influence of scan rate, between 10 and 100 mV/s, on the current response. As it can be observed from this <xref ref-type="fig" rid="fig">Figure </xref>4(a) the oxidative current peak is enhanced with the raise of scan rate; the plot of the current vs the square root of the scan rate showed a linear behaviour indicating that the process is diffusion controlled.</p><p><xref ref-type="fig" rid="fig">Figure </xref>5 shows the amperometric response of the NiO nanostructures based sensor electrode measured at + 0.5 V in 0.1 M NaOH solution. Upon the addition of different concentrations of glucose, it can be found that NiO</p></sec></sec></body><back><ref-list><title>References</title><ref id="scirp.40526-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Z. Yang, J. Feng, J. Qiao, Y. Yan, Q. Yu and K. Sun, “Copper Oxide Nanoleaves Decorated Multi-Walled Carbon Nanotube as Platform for Glucose Sensing,” Analytical Methods, Vol. 4, No. 7, 2012, pp. 1924-1926.  
http://dx.doi.org/10.1039/c2ay25283j</mixed-citation></ref><ref id="scirp.40526-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">G. P. Hicks and S. J. Updike, “The Enzyme Electrode,” Nature, Vol. 214, 1967, pp. 986-988.  
http://dx.doi.org/10.1038/214986a0</mixed-citation></ref><ref id="scirp.40526-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">L. Hu, S. Han, Z. Liu, S. Parveen, Y. Yuan and G. Xu, “A Versatile Strategy for Electrochemical Detection of Hydrogen Peroxide as well as Related Enzymes and Substrates Based on Selective Hydrogen Peroxide-Mediated Boronate Deprotection,” Electrochemistry Communication, Vol. 13, No. 12, 2011, pp. 1536-1538.  
http://dx.doi.org/10.1016/j.elecom.2011.10.016</mixed-citation></ref><ref id="scirp.40526-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">A. M. Vinu Mohan, K. K. Ashwini, A. Maria Starvin and V. M. Biju, “Amperometric Detection of Glucose Using Prussian Blue-Graphene Oxide Modified Platinum Electrode,” Analytical Methods, Vol. 5, No. 7, 2013, pp. 1764-1770. http://dx.doi.org/10.1039/c3ay26310j</mixed-citation></ref><ref id="scirp.40526-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">V. Mani, B. Devadas and S. M. Chen, “Direct Electrochemistry of Glucose Oxidase at Electrochemically Reduced Graphene Oxide-Multiwalled Carbon Nanotubes Hybrid Material Modified Electrode for Glucose Biosensor,” Biosensor Bioelectronic, Vol. 41, 2013, pp. 309-315.  
http://dx.doi.org/10.1016/j.bios.2012.08.045</mixed-citation></ref><ref id="scirp.40526-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">A. Sun, J. Zheng and Q. Sheng, “A Highly Sensitive Non-Enzymatic Glucose Sensor Based on Nickel and Multi-Walled Carbon Nanotubes Nanohybrid Films Fabricated by One-Step Co-Electrodeposition in Ionic Liquids,” Electrochimca Acta, Vol. 65, 2012, pp. 64-69.  
http://dx.doi.org/10.1016/j.electacta.2012.01.007</mixed-citation></ref><ref id="scirp.40526-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Y. Mu, D. Jia, Y. He, Y. Miao and H. L. Wu, “Nano Nickel Oxide Modified Non-Enzymatic Glucose Sensors with Enhanced Sensitivity through an Electrochemical Process Strategy at High Potential,” Biosensor Bioelectronics, Vol. 26, No. 6, 2011, pp. 2948-2952.  
http://dx.doi.org/10.1016/j.bios.2010.11.042</mixed-citation></ref><ref id="scirp.40526-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">C. Guo, Y. Wang, Y. Zhao and C. Xu, “Non-Enzymatic Glucose Sensor Based on Three Dimensional Nickel Oxide for Enhanced Sensitivity,” Analytical Methods, Vol. 5, No. 7, 2013, pp. 1644-1647.  
http://dx.doi.org/10.1039/c3ay00067b</mixed-citation></ref><ref id="scirp.40526-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">J. Chen, W. D. Zhang and J. S. Ye, “Nonenzymatic Electrochemical Glucose Sensor Based on MnO2/MWNTs Nanocomposite,” Electrochemistry Communications, Vol. 10, No. 9, 2008, pp. 1268-1271.  
http://dx.doi.org/10.1016/j.elecom.2008.06.022</mixed-citation></ref><ref id="scirp.40526-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">X. Wang, X. Dong, Y. Wen, C. Li, Q. Xiong and P. Chen, “A Graphene-Cobalt Oxide Based Needle Electrode for Non-Enzymatic Glucose Detection in Micro-Droplets,” Chemical Communication, Vol. 48, No. 52, 2012, pp. 6490-6492. http://dx.doi.org/10.1039/c2cc32674d</mixed-citation></ref><ref id="scirp.40526-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">M. F. Wang, Q. A. Huang, X. Z. Li and Y. Wei, “Mesoporous CuO: Alternative Enzyme-Free Glucose Sensing Structure with Excellent Kinetics of Electrode Process,” Analytical Methods, Vol. 4, No. 10, 2012, pp. 3174-3179. http://dx.doi.org/10.1039/c2ay25501d</mixed-citation></ref><ref id="scirp.40526-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">D. Tao and F. Wei, “New Procedure towards Size-Homogeneous and Well-Dispersed Nickel Oxide Nanoparticles of 30 nm,” Materials Letters, Vol. 58, No. 25, 2004, pp. 3226-3228. http://dx.doi.org/10.1016/j.matlet.2004.06.015</mixed-citation></ref><ref id="scirp.40526-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">K. C. Liu and M. A. Anderson, “Porous Nickel Oxide/ Nickel Films for Electrochemical Capacitors,” Journal of The Electrochemical Society, Vol. 143, No. 1, 1996, pp. 124-131. http://dx.doi.org/10.1149/1.1836396</mixed-citation></ref><ref id="scirp.40526-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Y. D. Wang, C. L. Ma, X. D. Sun and H. D. Li, “Preparation of Nanocrystalline Metal Oxide Powders with the Surfactant-Mediated Method,” Inorganic Chemistry Communications, Vol. 5, No. 10, 2002, pp. 751-755.  
http://dx.doi.org/10.1016/S1387-7003(02)00546-4</mixed-citation></ref><ref id="scirp.40526-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">L. Xiang, X. Y. Deng and Y. Jin, “Experimental Study on Synthesis of NiO Nano-Particles,” Scripta Materialia, Vol. 47, No. 4, 2002, pp. 219-224.  
http://dx.doi.org/10.1016/S1359-6462(02)00108-2</mixed-citation></ref><ref id="scirp.40526-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">S. Deki, H. Yanagimito and S. Hiraoka, “NH2-Terminated Poly (ethylene oxide) Containing Nanosized NiO Particles: synthesis, characterization, and Structural Considerations,” Chemistry of Materials, Vol. 15, No. 26, 2003, pp. 4916-4922. http://dx.doi.org/10.1021/cm021754a</mixed-citation></ref><ref id="scirp.40526-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">B. Cheng, Y. Le, W. Q. Cai and J. G. Yu, “Synthesis of Hierarchical Ni(OH)2 and NiO Nanosheets and Their Adsorption Kinetics and Isotherms to Congo Red in Water,” Journal of Hazardous Materials, Vol. 185, No. 2-6, 2010, pp. 889-897.  
http://dx.doi.org/10.1016/j.jhazmat.2010.09.104</mixed-citation></ref><ref id="scirp.40526-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">M. Villagran, J. Costamagna and J. H. Zagal, “Nickel(II) Complexes with Tetraaza Macrocycles in the Electrocatalytic Oxidation of Sulfite,” Journal of Coordination Chemistry, Vol. 59, No. 13, 2006, pp. 1467-1476.  
http://dx.doi.org/10.1080/00958970600559484</mixed-citation></ref><ref id="scirp.40526-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Z. H. Ibupoto, S. M. Usman Ali, C. O. Chey, K. Khun, O. Nur and M. Willander, “Selective Zinc Ion Detection by Functionalised ZnO Nanorods with Ionophore,” Journal of Applied Physics, Vol. 110, No. 10, 2011, Article ID: 104702. http://link.aip.org/link/doi/10.1063/1.3662107</mixed-citation></ref></ref-list></back></article>