<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJSST</journal-id><journal-title-group><journal-title>Open Journal of Safety Science and Technology</journal-title></journal-title-group><issn pub-type="epub">2162-5999</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojsst.2013.33007</article-id><article-id pub-id-type="publisher-id">OJSST-37089</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Chemistry&amp;Materials Science</subject><subject> Engineering</subject><subject> Social Sciences&amp;Humanities</subject></subj-group></article-categories><title-group><article-title>
 
 
  Fabricated Antibacterial and Bioactive Titania Nanotube Arrays Coating on the Surface of Titanium
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>ian</surname><given-names>Tian</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Haicheng</surname><given-names>Dong</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Xiaoting</surname><given-names>Tian</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yafei</surname><given-names>Hao</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib></contrib-group><aff id="aff3"><addr-line>Erdos Wushen Banner People’s Hospital, Erdos, China</addr-line></aff><aff id="aff1"><addr-line>State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi’an, China;
No. 52 Institute of China Ordnance Industries, Baotou, China</addr-line></aff><aff id="aff2"><addr-line>No. 52 Institute of China Ordnance Industries, Baotou, China</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>fjnutiantian@163.com(IT)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>20</day><month>09</month><year>2013</year></pub-date><volume>03</volume><issue>03</issue><fpage>59</fpage><lpage>62</lpage><history><date date-type="received"><day>May</day>	<month>30,</month>	<year>2013</year></date><date date-type="rev-recd"><day>June</day>	<month>29,</month>	<year>2013</year>	</date><date date-type="accepted"><day>July</day>	<month>13,</month>	<year>2013</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   By photic-assisted deposition, Ag nanoparticles were assembled on bioactive TiO<sub>2</sub> nanotube arrays, which were fabricated by anodic oxidation in 0.5 wt% NH<sub>4</sub>F solution containing 0.5 wt% Na<sub>2</sub>HPO<sub>4</sub>. The samples were characterized by scanning electron mincroscope (SEM), X-ray diffraction (XRD). Germiculture experimentation was employed to testing samples’ antibacterial capability. An obvious antibacterial ring appeared around the Ag modified samples, indicating that Ag modified titania nanotube arrays has good antibacterial capability.
     
 
</p></abstract><kwd-group><kwd>Antibacterial; Bioactive; TiO2 Nanotube Arrays</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>It is well known that titanium is widely used as bone implant materials because it has excellent biocompatibility and mechanical properties that enhance osseointegration. Nevertheless, it has not bioactive compared to bioactive materials, and requires bio-activation. According to literatures, surface treatments of bioactivities have led to improvements in the adhesion of osteoblasts and their proliferation [1-4]. The surface morphology and composition of the titanium can be regulated by surface treatments, such as alkali and heat treatment, etching, spray, anodizing, and so on.</p><p>Branemark et al. [<xref ref-type="bibr" rid="scirp.37089-ref5">5</xref>] reported that titanium and titanium-based alloys can be used as implant materials, many attempts have been made to modify the structure, composition, and chemistry of the titanium surfaces including fabrication of titania coating [6-11], including the fabrication of bioactive TiO<sub>2</sub> nanotube arrays [12,13]. Tian Tian et al. [<xref ref-type="bibr" rid="scirp.37089-ref12">12</xref>] studied the effect of crystal structure of TiO<sub>2</sub> nanotube arrays bioactivity and found that a mixture titania nanotube of anatase and rutile are clearly more efficient in promoting apatite formation than the amorphous state. Xiao Xiufeng et al. [<xref ref-type="bibr" rid="scirp.37089-ref13">13</xref>] found that the bioactive titania nanotube arrays can form on the surface of titanium by anodic oxidation in hydrofluoric (HF) electrolyte with the addition of 5 - 10 g/L Na<sub>2</sub>HPO<sub>4</sub>, <img src="3-1480070\663aee68-4758-4c7d-ac55-3176f586f9de.jpg" />ions remained in the tube attract Ca<sup>2+</sup> in simulated body fluid and induce the nucleation of apatite.</p><p>The intuitionistic plot of the titania nanotube arrays is shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>(a), the empty space of titania nanotube is very useful for modifying, such as fill something with especial function into it, the intuitionistic plot of modified titania nanotube arrays as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>(b).</p><p>Therefore, the present study was aimed to manufacture a new bioactive titanium implant material by modifying bioactive titania nanotube arrays, which will has antibacterial action. Once the bioactive titanium implant material has antibacterial action, they can avoid surgery failing because of infection.</p></sec><sec id="s2"><title>2. Experiment Section</title><sec id="s2_1"><title>2.1. Preparation of Bioactive Titania Nanotube Arrays</title><p>Prior to anodization, the titanium foils (99.5% pure) were ultrasonically cleaned in acetone and distilled water for 5 min, then chemistry eroded in 4 wt% HF + 5 mol/L HNO<sub>3</sub> for 30S, followed by ultrasonically cleaned in distilled water for 5 min and dried in air at 40 of centigrade. A two-electrode with a graphite cathode was employed for the anodization of titanium. 0.5 wt% NH<sub>4</sub>F solution counting 5 g/L Na<sub>2</sub>HPO<sub>4</sub> solution was used as electrolytes. All electrolytes were prepared from reagent grade</p><p>chemicals and DI water. The anodizing voltage was kept constant during the entire process with a DC power supply (GOA, China) at 20 V. The whole course of anodizing was conducted at room temperature (25 of centigrade) with magnetic agitation. After anodizing, the samples were rinsed with DI water and then dried at 40 of centigrade in air. The as-prepared sample was signed as NA1.</p><p>Heat treated the sample NA1 at 500˚C in muffle with air for 1hour, and signed it as NA2.</p></sec><sec id="s2_2"><title>2.2. Ag Modified Bioactive Titania Nanotube Arrays</title><p>After immerging the samples into 0.1 mol∙L<sup>−1</sup> AgNO<sub>3</sub> solutions for 2 min, irradiated the samples by ZF-II UV lamp with the wavelengh of 365 nm and the intensity of 1400 mw∙cm<sup>−2</sup> for 2 min. Repeat the process three times. At last ultrasonically cleaned the samples with DI water and dried them at 40˚C in air, and signed the sample as NA3.</p></sec><sec id="s2_3"><title>2.3. Antibacterial Researches</title><p>Staphyloccocus aureus is an important pathogeny bacterium for human. It can evoke many badly infection. So the staphyloccocus aureus was used in the antibacterial researches.</p><p>Firstly, coated the MH agar plate onto the petri dish, and then coated the asepsis physiological brine with 0.5 wt% staphyloccocus aureus onto the MH agar plate, ultimately put the petri dish into the electrothermal incubator with 37˚C temperature for 12 hours and 24 hours. But 12 hours is not enough for antibacterial researches to make a distinction. Therefore longer time spend on the antibacterial researches in this section.</p></sec><sec id="s2_4"><title>2.4. Characterization</title><p>Scanning electron microscopy (SEM) was used to determine surface morphology using HITACHI-S3400N SEM. The compositions of the coating were determined with an energy dispersive X-ray spectrometer (EDX).</p></sec></sec><sec id="s3"><title>3. Results and Discussions</title><p>From <xref ref-type="fig" rid="fig2">Figure 2</xref>, we can see the mouth of titania nano-</p><p>tube. When the sample NA3 was tested by XRD, Ti peak and TiO<sub>2</sub> peak appeared but there is no Ag peak on the XRD patterns. The result of XRD is shown in <xref ref-type="fig" rid="fig3">Figure 3</xref> XRD of NA3.</p><p>The results indicated that the amount of Ag is little. The compositions of the coating were determined with EDX, the result as shown in <xref ref-type="fig" rid="fig4">Figure 4</xref>. There has about 2.3 wt% Ag formed on the surface of the sample.</p><p>The results of the EDX and the real reaction as follow can prove effectively that Ag have formed on the surface of NA3. The results indicated that Ag modified was successful.</p><p><img src="3-1480070\2d035787-9133-4ed4-aa17-7d9efb2b6920.jpg" /></p><p>In antibacterial researches, there is an obviously antibacterial ring formed around the NA3, and there is no antibacterial ring formed around the NA1 and NA2 as contrast. The result is shown in <xref ref-type="fig" rid="fig5">Figure 5</xref>, the result of antibacterial researches. The results indicate that Ag modified is successful, the above process endow the bioactive titania nanotube arrays with good antibacterial capability.</p><p>It is well known that Ag has good antibacterial capability. Modifying the bioactive titania nanotube arrays with Ag is a good idea for the fabrication of the antibacterial bioactive titania nanotube arrays.</p></sec><sec id="s4"><title>4. Conclusion</title><p>The antibacterial bioactive titania nanotube arrays can be obtained by follow method: modify the bioactive titania nanotube arrays with Ag. Anodic oxidation treatment and Ag modified are economical method for surface antibacterial bioactive treatment.</p></sec><sec id="s5"><title>5. Acknowledgements</title><p>The authors would like to thanks the Research Foundation of Baotou City Youth Innovation and the Research Foundation of Zhejiang Province Public Technology Research and industrial projects (2013C31051).</p></sec><sec id="s6"><title>REFERENCES</title></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.37089-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Z. Schwartz, K. Kieswetter, D. D. Dean and B. D. Boyan, “Underlying Mechanism at the Bone-Surface Interface during Regeneration,” Journal of Periodontal Research, Vol. 32, No. 1, 1997, pp. 166-171. 
doi:10.1111/j.1600-0765.1997.tb01399.x</mixed-citation></ref><ref id="scirp.37089-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">B. Chehroudi, D. McDonnel and D. M. Brunette, “The Effects of Micromachined Surfaces on Formation of Bonelike Tissue on Subcutaneous Implants as Assessed by Radiography and Computer Image Processing,” Journal of Biomedical Materials Research, Vol. 34, No. 3, 1997, pp. 279-290. 
doi:10.1002/(SICI)1097-4636(19970305)34:3&lt;279::AID-JBM2&gt;3.0.CO;2-H</mixed-citation></ref><ref id="scirp.37089-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">X. Zhu, J. Chen, L. Scheideler, T. Altebaeumer and J. GeisGerstorfer, “Cellular Reactions of Osteoblasts to Micron and Submicron-Scale Porous Structures of titanium Surfaces,” Cells Tissues Organs, Vol. 178, 2004, pp. 13-22. doi:10.1159/000081089</mixed-citation></ref><ref id="scirp.37089-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">G. E. II Aninwene, C. Yao and T. J. Webster, “Enhanced Osteoblast Adhesion to Drug-Coated Anodized Nanotu- bular Titanium Surfaces,” International Journal of Nanomedicine, Vol. 3, No. 2, 2008, pp. 257-264.</mixed-citation></ref><ref id="scirp.37089-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">P. I. Branemark, “Osseointegrated Implants in the Treatment of the Edentulous Jaw. Experience from a 10-Year Period,” Journal of Plastic and Reconstructive Surgery, Vol. S16, 1977, pp. 1-132.</mixed-citation></ref><ref id="scirp.37089-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">P. Babelon, A. S. Dequiedt, H. Moste’fa-Sba, S. Bourgeois, P. Sibillot and M. Sacilotti, “SEM and XPS Studies of Titanium Dioxide Thin Films Grown by MOCVD,” Thin Solid Films, Vol. 322, No. 1-2, 1998, pp. 63-67. 
doi:10.1016/S0040-6090(97)00958-9</mixed-citation></ref><ref id="scirp.37089-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">S. Thybo, S. Jensen, J. Johansen, T. Johannessen, O. Hansen and U. J. Quaade, “Flame Spray Deposition of Porous Catalysts on Surfaces and in Microsystems,” Journal of Catalysis, Vol. 223, No. 2, 2004, pp. 271-277.  
doi:10.1016/j.jcat.2004.01.027</mixed-citation></ref><ref id="scirp.37089-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">N. N. Dinh, N. T. T. Oanh, P. D. Long, M. C. Bernard and A. H. Goff, “Electrochromic Properties of TiO2 Anatase Thin Films Prepared by a Dipping Sol-Gel Method,” Thin Solid Films, Vol. 423, No. 1, 2003, pp. 70-76. 
doi:10.1016/S0040-6090(02)00948-3</mixed-citation></ref><ref id="scirp.37089-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">C. Lee, H. Choi, C. Lee and H. Kim, “Photocatalytic Properties of Nano-Structured TiO2 Plasma Sprayed Coating,” Surface Coat Technology, Vol. 173, No. 2-3, 2003, pp. 192-200.</mixed-citation></ref><ref id="scirp.37089-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">T. Sumita, T. Yamaki, S. Yamamoto and A. Miyashita, “Photo-Induced Surface Charge Separation in Cr-Implanted TiO2 Thin Films,” Thin Solid Films, Vol. 416, No. 1-2, 2002, pp. 80-84. doi:10.1016/S0040-6090(02)00618-1</mixed-citation></ref><ref id="scirp.37089-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">H. Ohsaki, Y. Tachibana, A. Mitsui, T. Kamiyama and Y.</mixed-citation></ref><ref id="scirp.37089-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Hayashi, “High Rate Deposition of TiO2 by DC Sputtering of the TiO2-x Target,” Thin Solid Films, Vol. 392, No. 2, 2001, pp. 169-173.  
doi:10.1016/S0040-6090(01)01023-9</mixed-citation></ref><ref id="scirp.37089-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">T. Tian, X. Xiufeng, S. Houde and L. Rongfang, “Biomimetic Growth of Apatite on Titania Nanotube Arrays Fabricated by Titanium Anodization in NH4F/H2SO4 Electrolyte,” Materials Science-Poland, Vol. 26, No. 3, 2008, pp. 487-494.</mixed-citation></ref><ref id="scirp.37089-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">X. Xiufeng, L. Rongfang and T. Tian, “Preparation of Bioactive Titania Nanotube Arrays in HF/Na2HPO4 Electrolyte,” Journal of Alloys and Compounds, Vol. 466, No. 1-2, 2008, pp. 356-362.</mixed-citation></ref></ref-list></back></article>