<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">OJAB</journal-id><journal-title-group><journal-title>Open Journal of Applied Biosensor</journal-title></journal-title-group><issn pub-type="epub">2168-5401</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ojab.2013.21002</article-id><article-id pub-id-type="publisher-id">OJAB-28310</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Biomedical&amp;Life Sciences</subject><subject> Chemistry&amp;Materials Science</subject></subj-group></article-categories><title-group><article-title>
 
 
  Urea Amperometric Biosensors Based on Nanostructured Polypyrrole and Poly Ortho-Phenylenediamine
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>vetla</surname><given-names>Ivanova</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yavor</surname><given-names>Ivanov</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tzonka</surname><given-names>Godjevargova</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>University “Prof. Assen Zlatarov”, Burgas, Bulgaria</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>godjevargova@yahoo.com(TG)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>27</day><month>02</month><year>2013</year></pub-date><volume>02</volume><issue>01</issue><fpage>12</fpage><lpage>19</lpage><history><date date-type="received"><day>December</day>	<month>20,</month>	<year>2012</year></date><date date-type="rev-recd"><day>January</day>	<month>23,</month>	<year>2013</year>	</date><date date-type="accepted"><day>February</day>	<month>6,</month>	<year>2013</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
   Urea Amperometric biosensor was obtained on the base of nanostructured polypyrrole (PPy) and poly ortho- phenylenediamine (POPDA). The optimal conditions for monomer electropolymerization were determined. The effect of supporting electrolyte and number of deposition cycles on the OPDA and Py electropolymerization were studied. It was proved that POPDA and PPy were affected by pH changes and responded to the ammonium, product of urease catalyzed reaction. SEM images of the modified Pt/PPy electrode were presented. The cycle voltammograms and chrono amperometric curves of Pt/POPDA/urease and Pt/PPy/urease electrodes were studied. A good linear relationship was observed for Pt/POPDA/urease electrode in a concentration range from 6.7 to 54 mMurea. For Pt/PPy/urease electrode the linear relation in the range from 0.02 to0.16 mMurea was determined. The entrapped carbon nanotubes (CNT) in PPy film and the bipolymer layers were prepared for construction of Pt/PPy/CNT/urease, Pt/POPDA/PPy/urease and Pt/PPy/POPDA/urease biosensors. Obviously, the addition of POPDA to the composition of the two biosensors (Pt/PPy/POPDA/urease and Pt/POPDA/PPy/urease) reduced their sensitivity to urea. Pt/РPy/CNT/urease and Pt/РPy/ urease biosensors were 173 and 138 times more sensitive to urea than biosensor without PPy (Pt/POPDA/urease biosensor). It was found, that the performance of Pt/PPy/CNT/urease electrode was the best from the five obtained biosensors: linear range of urea concentrations—from 0.02 to0.16 mM; sensitivity—15.22 μA/mM and detection limit— 0.005 mM urea. 
 
</p></abstract><kwd-group><kwd>Biosensor; Urea; Urease; Electrodeposition; Polypyrrole; Poly Ortho-Phenylenediamine; Carbon Nanotubes</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The urea concentration in serum or urine is an indicator of kidney diseases, as well as diabetes, and analysis in clinical laboratories is frequently used. In a urea biosensor the enzyme urease, which catalyses the hydrolysis of urea to ammonia and carbonate can be immobilized into different transducers, such as conducting polymers. Various conducting polymers, like polyaniline (PANi), polypyrrole (PPy) and poly ortho-phenylenediamine, have been used for the fabrication of biosensors. Among them, polypyrrole is one of the most extensively used conducting polymers in the fabrication of urease biosensors [<xref ref-type="bibr" rid="scirp.28310-ref1">1</xref>]. The versatility of this polymer is determined by its biocompatibility, capability to transduce energy arising from the interaction of analytes and analyte recognizing sites into electrical signals that are easily monitored, capability to protect electrodes from interfering material, and easy way for electro-chemical deposition on the surface of any type of electrode.</p><p>As opposed to PPy, POPDA shows the conductivity in its reduced state, whereas its oxidized state is insulating. This determines the electrochemical properties of POPDA, since many electrode redox processes of solution species have been shown to take place within relatively narrow potential window, corresponding to the reduced (conducting) form of this polymer [<xref ref-type="bibr" rid="scirp.28310-ref2">2</xref>]. Recently nanoparticles enhancing enzyme immobilization technique have become widespread. The using of carbon nanotubes (CNT) as mediators of the electron transfer from the enzyme molecules to the electrode surface is often applied. Their unique electronic properties suggest that CNT have the ability to promote the electron transfer reactions of biomolecules in electrochemistry [<xref ref-type="bibr" rid="scirp.28310-ref3">3</xref>]. Their mechanical properties, high-aspect ratio, electrical conductivity and chemical stability make CNT perfect for a wide range of applications that include fabrication of urease biosensors [<xref ref-type="bibr" rid="scirp.28310-ref4">4</xref>].</p><p>A variety of urease biosensors with high sensitivity and excellent reproducibility based on nanostructured polypyrrole [5-9], poly ortho-phenylenediamine [10,11] and carbon nanotubes [12,13] has been reported.</p><p>The aim of this paper was to study the conditions for preparation of urea amperometric biosensor based on nanostructured polypyrrole, poly ortho-phenylenediamine, multi-layered nanostructured substrates and comparing the performance of obtained biosensors.</p></sec><sec id="s2"><title>2. Experimental</title><sec id="s2_1"><title>2.1. Reagents and Chemicals</title><p>Pyrrole (Py), 98% from Sigma-Aldrich, USA; orthophenylenediamine (OPDA) from Merck; urease ЕС 3.5.1.5, 112 U∙mg<sup>−</sup><sup>1</sup> from Fluka; carbon nanotubes (CNT) from Sigma Aldrich with size 2 - 6 nm and length 0.1 - 10 &#181;m, with 90% purity; glutaraldehyde from Merck. All reagents were of analytical grade. All solutions were prepared using deionized water from PURELAB Ultrasystem.</p></sec><sec id="s2_2"><title>2.2. Instrumentation</title><p>Cyclic voltammetric, amperometric measurements and electropolymerization of Py and OPDA monomers on working electrode surface were carried out with the PalmSens Electrochemical Instrument (Palm Instruments BV, Netherlands) and three-electrode electrochemical cell: a platinum plate electrode (1 cm<sup>2</sup> area) as a working electrode, platinum wire as a counter electrode and a saturated calomel (SCE) or Ag/AgCl electrodes as reference electrodes were used both in the cyclic voltammetric and amperometric measurements.</p></sec><sec id="s2_3"><title>2.3. Cleaning of the Working Electrode Surface</title><p>The working electrode was mechanically polished with 0.3 and 0.05 &#181;m alumina, rinsed with distilled water, acetone and once again with water. Then, it was cleaned electrochemically in 1 M H<sub>2</sub>SO<sub>4</sub> by potential cycling between −0.25 and +1.45 V versus Ag/AgCl at a scan rate of 0.075 V/s for 10 - 15 min. Before electropolymerization, the monomer solutions (Py or OPDA) were purged with high-purity nitrogen gas for at least 10 min in order to remove dissolved oxygen. An inert environment was maintained in the electrochemical cell during the polymerization by purging the cell atmosphere with a flow of nitrogen.</p></sec><sec id="s2_4"><title>2.4. Preparation of Pt/POPDA/Urease Biosensor</title><p>OPDA was electropolymerized by continuous potential cycling between −0.4 and +1.0 V vs. SCE, at a scan rate of 0.05 V/s. The number of deposition cycles was varied (1, 10 and 20 cycles). The electropolymerization was carried out in 0.1М H<sub>2</sub>SO<sub>4</sub> or 0.1M KCI as supporting electrolyte containing 0.05 M OPDA monomer solution. Then, the working electrode was dried at room temperature. A 5 &#181;L of 25% glutaraldehyde was pipette on the electrode surface and the solution was allowed to evaporate at 30˚C for 30 min. The urease was immobilized on the POPDA surface by pipetting a 5 &#181;L of 0.1% urease and the electrode was dried at 4˚C.</p></sec><sec id="s2_5"><title>2.5. Preparation of Pt/PPy/Urease Biosensor</title><p>The electropolymerization of Py was carried out in 0.1 М KCl as supporting electrolyte, containing 0.1 М NaCl and 0.4 М Py monomer solution. The final concentration of urease in this solution was 0.1%. The working electrode potential was cycled in the potential range from −1.0 to +0.7 V vs Ag/AgCl, at a scan rate of 0.05 V/s, 30 cycles.</p>• 2.6. Preparation of Multi-Layered Nanostructured Urease Biosensor<sec id="s2_5_1"><title>Pt/PPy/CNT/urease biosensor</title><p>The electropolymerization of Py was carried out in 0.1 М KCl as supporting electrolyte, containing 0.1 М NaCl and 0.4 М Py monomer solution. 0.0016 g CNT were added and the mixture was homogenized by sonication for 1 h. Then urease was added to this solution to a final concentration of 0.1%. The working electrode potential was cycled in the potential range of −1.0 to +0.7 V at a scan rate of 0.05 V/s for 30 cycles.</p></sec><sec id="s2_5_2"><title>Pt/POPDA/PPy/urease biosensor</title><p>POPDA was deposited on working electrode by the method described above. After that the electrode was dried at room temperature and deposited the second polymer layer of PPy with entrapping urease, as described above.</p></sec><sec id="s2_5_3"><title>Pt/PPy/POPDA/urease biosensor</title><p>POPDA film was deposited on Pt/PPy/urease electrode by the method described above.</p>• 2.7. Electrochemical Measurements with Urease Biosensor</sec><sec id="s2_5_4"><title>Cyclic voltammetry</title><p>Cyclic voltammograms (CVs) of Pt/POPDA/urease electrode were carried out in 30 mL of 0.01 M PBS (pH 5.8) in the absence and presence of 100 &#181;L of 1М urea. The working electrode potential was cycled in the potential range of −1.0 to +1.5 V.</p><p>Cyclic voltammograms of Pt/PPy/urease electrode were carried out in 10 mL of 0.01 M PBS (pH 5.8), containing 0.1 M NaCl, in the absence and presence of 200 &#181;L of 10 mМ urea. The working electrode potential was cycled in the potential range of −1.0 to +0.7 V.</p></sec><sec id="s2_5_5"><title>Chronoamperometry</title><p>Chronoamperometry was used as the transduction method for detecting urea in different solutions. The current density was measured for films potentiostatically polarized at a fixed potential −0.1 V for Pt/POPDA/ urease and −0.6 V for Pt/PPy/urease biosensors, at successive addition of 100 &#181;L of 1 M urea (pH 5.8) and 200 &#181;L of 10 mM urea (pH 5.8), respectively. This value of pH allowed us to achieve a condition of maximum activity of urease.</p></sec></sec></sec><sec id="s3"><title>3. Results and Discussion</title><sec id="s3_1"><title>3.1. Preparation of Pt/POPDA/Urease Biosensor</title><p>The first step for developing of urea biosensor was to choose the optimum conditions for monomer electropolymerization. Several experiments have been carried out to obtain stable and active polymeric film. The effect of supporting electrolyte and number of deposition cycles on the OPDA electropolymerization were studied. <xref ref-type="fig" rid="fig1">Figure 1</xref> shows the CVs of the ОPDA electropolymerization −0.05 M ОPDA in 0.1 М KCl (dashed line) and 0.05 M ОPDA in 0.1 М H<sub>2</sub>SO<sub>4</sub> (solid line). The results demonstrated that the acidity of the electrolyte had a very strong effect on the electropolymerization process. The CV curve, obtained in H<sub>2</sub>SO<sub>4</sub>, is much wider compared with the CV curve obtained in KCl. This is probably due to the different conductivity of POPDA film in both electrolytes. Thus, 0.1 М H<sub>2</sub>SO<sub>4</sub> was chosen as supporting electrolyte for the OPDA electropolymerization.</p><p><xref ref-type="fig" rid="fig2">Figure 2</xref> shows CV curves of Pt/POPDA electrode as a function of different number of deposition cycles—1, 10 and 20. At 1st deposition cycle a high and wide oxidation peak was appeared at +0.70 V. This was attributed to the oxidation of the monomer on the clean Pt electrode and formation of POPDA film. In the following negative sweep, a reduction peak at −0.18 V was observed, which is much lower than the oxidation peak. At 10 deposition cycle the oxidation and reduction peaks were decreased. Besides that, with the increasing of number of deposition cycles, the anodic and cathodic peaks shifted to +0.54</p></sec></sec></body><back><ref-list><title>References</title><ref id="scirp.28310-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">B. Gupta, S. Singh, S. Mohan and R. Prakash, “Urea Biosensor based on Conducting Polymer Transducers,” In: P. A. Serra, Ed., Biosensors, InTech, Rijeka, 2010, p. 302.</mixed-citation></ref><ref id="scirp.28310-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">J. C. Vidal, S. MeAndez and J. R. Castillo, “Electropolymerization of Pyrrole and Phenylenediamine over an Organic Conducting Salt Based Amperometric Sensor of Increased Selectivity for Glucose Determination,” Analytica Chimica Acta, Vol. 385, No. 1-3, 1999, pp. 203- 211. doi:10.1016/S0003-2670(98)00837-X</mixed-citation></ref><ref id="scirp.28310-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">S. Vishwanath, J. Wang, L. G. Bachas, D. A. Butterfield and D. Bhattacharyya, “Site-Directed and Random Immobilization of Subtilisin on Functionalized Membranes: Activity Determination in Aqueous and Organic Media,” Biotechnology and Bioengineering, Vol. 60, No. 5, 1998, pp. 608-616. doi:10.1002/(SICI)1097-0290(19981205)6</mixed-citation></ref><ref id="scirp.28310-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Y. Yao and K. K. Shiu, “Electron-Transfer Properties of Different Carbon Nanotube Materials, and Their Use in Glucose Biosensors,” Analytical and Bioanalytical Chemistry, Vol. 387, No. 1, 2007, pp. 303-309.  
doi:10.1007/s00216-006-0924-1</mixed-citation></ref><ref id="scirp.28310-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">J. C. Soares, A. Brisolari, V. C. Rodrigues, E. A. Sanches and D. Goncalves, “Amperometric Urea Biosensors Based on the Entrapment of Urease in Polypyrrole Films,” Reactive and Functional Polymers, Vol. 72, No. 2, 2012, pp. 148-152. doi:10.1016/j.reactfunctpolym.2011.12.002</mixed-citation></ref><ref id="scirp.28310-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">M. P. Massafera and S. I. C. Torresi, “Urea Amperometric Biosensors Based on Nanostructured Polypyrrole,” Electroanalysis, Vol. 23, No. 11, 2011, pp. 2534-2540. 
doi:10.1002/elan.201100239</mixed-citation></ref><ref id="scirp.28310-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">S. B. Adeloju, S. J. Shaw and G. G. Wallace, “Polypyrrole-Based Amperometric Flow Injection Biosensor for Urea,” Analytica Chimica Acta, Vol. 323, No. 1-3, 1996, pp. 107-113. doi:10.1016/0003-2670(95)00562-5</mixed-citation></ref><ref id="scirp.28310-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">S. Adeloju, S. Shaw and G. Wallace, “Pulsed-Amperometric Detection of Urea in Blood Samples on a Conducting Polypyrrole-Urease Biosensor,” Analytica Chimica Acta, Vol. 341, No. 2-3, 1997, pp. 155-160.  
doi:10.1016/S0003-2670(96)00502-8</mixed-citation></ref><ref id="scirp.28310-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">M. P. Massafera and S. I. C. de Torresi, “Urea Amperometric Biosensors Based on a Multifunctional Bipolymeric Layer: Comparing Enzyme Immobilization Methods,” Sensors and Actuators B: Chemical, Vol. 137, No. 2, 2009, pp. 476-482. doi:10.1016/j.snb.2009.02.013</mixed-citation></ref><ref id="scirp.28310-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">M. Stred’anskya, A. Pizzariello, S. Stred’anská and S. Miertus, “Amperometric pH-Sensing Biosensors for Urea, Penicillin, and Oxalacetate,” Analytica Chimica Acta, Vol. 415, No. 1-2, 2000, pp. 151-157.  
doi:10.1016/S0003-2670(00)00869-2</mixed-citation></ref><ref id="scirp.28310-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">D. Chirizzi and C. Malitesta, “Potentiometric Urea Biosensor Based on Urease Immobilized by an Electrosynthesized Poly (o-Phenylenediamine) Film with Buffering Capability,” Sensors and Actuators B: Chemical, Vol. 157, No. 1, 2011, pp. 211-215.  
doi:10.1016/j.snb.2011.03.051</mixed-citation></ref><ref id="scirp.28310-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">F. Branzoi, V. Branzoi and A. Musina, “Amperometric Urea Biosensor Based on Platinum Electrode Modified with a Nanocomposite Film,” Surface and Interface Analysis, Vol. 44, No. 8, 2012, pp. 895-898.  
doi:10.1002/sia.4861</mixed-citation></ref><ref id="scirp.28310-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">J. Wang and M. Musameh, “Carbon-Nanotubes Doped Polypyrrole Glucose Biosensor,” Analytica Chimica Acta, Vol. 539, 2005, No. 1-2, pp. 209-213.  
doi:10.1016/j.aca.2005.02.059</mixed-citation></ref><ref id="scirp.28310-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">G. Gustafsson, I. Lundstrom, B. Liedberg, C. R. Wu and O. Inganas, “The Interaction between Ammonia and Poly (Pyrrole),” Synthetic Metals, Vol. 31, No. 2, 1989, pp. 163-179. doi:10.1016/0379-6779(89)90812-6</mixed-citation></ref><ref id="scirp.28310-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">M. Vidotti, L. H. Dall’Antonia, E. P. Cintra and S. I. C. Torresi, “Reduction of Interference Signal of Ascorbate and Urate in Poly(Pyrrole)-Based Ammonia Sensors in Aqueous Solutions,” Electrochimica Acta, Vol. 49, No. 22-23, 2004, pp. 3665-3670.  
doi:10.1016/j.electacta.2003.11.034</mixed-citation></ref><ref id="scirp.28310-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">V. Branzoi, F. Golgovicia and F. Branzoi, “Electronically Conductive Polymers Type Polypyrrole and Polyaniline Obtained by Electropolymerization onto Aluminium Substrate,” Revue Roumaine de Chimie, Vol. 53, No. 7, 2008, pp. 553-561.  
http://revroum.getion.ro/wp-content/uploads/2008/RRCh_7_2008/Art%2007.pdf</mixed-citation></ref><ref id="scirp.28310-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">W.-J. Cho and H.-J. Huang, “An Amperometric Urea Biosensor Based on a Polyaniline-Perfluorosulfonated Ionomer Composite Electrode,” Analytical Chemistry, Vol. 70, No. 18, 1998, pp. 3946-3951. doi:10.1021/ac980004a</mixed-citation></ref><ref id="scirp.28310-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">X. Wang, H. Watanabe, N. Sekioka, H. Hamana and S. Uchiyama, “Amperometric Urea Biosensor Using Aminated Glassy Carbon Electrode Covered with Urease Immobilized Carbon Sheet, Based on the Electrode Oxidation of Carbamic Acid,” Electroanalysis, Vol. 19, No. 12, 2007, pp. 1300-1306. doi:10.1002/elan.200603853</mixed-citation></ref><ref id="scirp.28310-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">P. P. Mishra, “Conducting Polymer-Coated Enzyme Microsensor for Urea,” Analyst, Vol. 113, No. 2, 1988, pp. 329-331. doi:10.1039/an9881300329</mixed-citation></ref><ref id="scirp.28310-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Rajesh, V. Bisht, W. Takashima and K. Kaneto, “An Amperometric Urea Biosensor Based on Covalent Immobilization of Urease onto an Electrochemically Prepared Copolymer Poly(N-3-aminopropyl pyrrole-co-pyrrole) Film,” Biomaterials, Vol. 26, No. 17, 2005, pp. 3683-3690.  
doi:10.1016/j.biomaterials.2004.09.024</mixed-citation></ref></ref-list></back></article>