<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">JEMAA</journal-id><journal-title-group><journal-title>Journal of Electromagnetic Analysis and Applications</journal-title></journal-title-group><issn pub-type="epub">1942-0730</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/jemaa.2012.47043</article-id><article-id pub-id-type="publisher-id">JEMAA-21269</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  Analysis of Land Subsidence Using the HES
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>itsarut</surname><given-names>Sriratana</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Riichi</surname><given-names>Murayama</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Intelligent Mechanical Engineering, Faculty of Engineering, Fukuoka Institute of Technology, Fukuoka, Japan</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>kswitsar@kmitl.ac.th(IS)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>23</day><month>07</month><year>2012</year></pub-date><volume>04</volume><issue>07</issue><fpage>310</fpage><lpage>316</lpage><history><date date-type="received"><day>May</day>	<month>2nd,</month>	<year>2012</year></date><date date-type="rev-recd"><day>June</day>	<month>4th,</month>	<year>2012</year>	</date><date date-type="accepted"><day>June</day>	<month>16th,</month>	<year>2012</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  This study presents a methodology for analysis of the industrial machine alignment in the production line. The level of land subsidence in the area of the industrial machine location was assessed by adopting Hall Effect Sensor (HES). A computer was used for real-time data collecting and displaying the angle of subsidence over operational period. The measurement module consists of two flat-curve permanent magnets mounted parallelly and the magnetic poles which were placed in position that can be generating the magnetic tension force. The center between two permanent magnets was the sensor namely HES placed perpendicularly to the magnetic fluxes. The permanent magnets were the moving parts which can be displaced depending on the inclined angle of land subsidence. Analysis of the relationship between the incline angle of the measurement module and the output voltage from the HES was considered from the function of subsidence angle and magnetic density on X-axis and perpendicular angle (Y-axis) with the resolution of 100 mV per degree. There were two ranges of measurement according to the angle resolution, –20 to 20 degree at 1 degree of resolution per step and –6 to 6 degree at 0.01 degree of resolution per step.
 
</p></abstract><kwd-group><kwd>HES; Incline; LSSM; Magnetic Field; Subsidence</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Industrial production line is one of the most important processes as it is dependent on the quality of products from manufacturing process. Therefore, the machines used in this process should provide good performance. Appropriate machine alignment and also building construction should be prepared for preventing ground subsidence. However, the most common problem would be the error in machine operation caused by the level of land subsidence in the areas where a number of large and heavyload machines are placed. Generally, the angle can be measured by using several methodologies [1-4]. Angular measurement based on magnetic field method using the HES was the alternative methodology to measure and monitor land subsidence. The measured results were in electrical voltage form obtained from output of HES and then transmitted to computer for real time monitoring and maintaining the appropriate position of the machines.</p></sec><sec id="s2"><title>2. Fundamental Method</title><sec id="s2_1"><title>2.1. Sensing Part and Error Analysis</title><p>HES is a small passive transducer (non-contact sensor) which is applicable in several purposes. The output voltage is generated when the constant current transmitting through a semiconductor namely Hall Generator is diverted [5,6]. In this study, the magnetic density (B) generated by sensing module can be analyzed by Lorenzt force (F) of the magnetic field on an electron (q) when changing the relative angle (q) and v is the velocity of electron due to electric field as given in Equation (1) [<xref ref-type="bibr" rid="scirp.21269-ref7">7</xref>].</p><disp-formula id="scirp.21269-formula129466"><label>(1)</label><graphic position="anchor" xlink:href="6-9801324\08741570-8842-43e5-b246-0b24649225ef.jpg"  xlink:type="simple"/></disp-formula><p>The output voltage from sensing of the HES (V<sub>H</sub>) as a function of the magnetic density can be calculated by Equations (2) and (3).</p><disp-formula id="scirp.21269-formula129467"><label>(2)</label><graphic position="anchor" xlink:href="6-9801324\a3e56155-bd17-46b3-8a85-e5c7bbaaf177.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.21269-formula129468"><label>(3)</label><graphic position="anchor" xlink:href="6-9801324\37bd780d-9812-4924-bd22-72fd99574349.jpg"  xlink:type="simple"/></disp-formula><p>where I<img src="6-9801324\c7919281-127e-4cef-974b-a886720794eb.jpg" /> is the current flowing through Hall generator on X-axis (A);</p><p>B is the density of magnetic field (Tesla);</p><p>d is the thickness of Hall generator (mm);</p><p>p is the number of holes;</p><p>n is the number of electrons.</p><p>The evaluation of value from repetitive measurements or random measurements is the estimation of uncertainty in type A standard. The standard deviation (Sd) will be considered as Estimate standard deviation in Equation (4) [<xref ref-type="bibr" rid="scirp.21269-ref8">8</xref>] when n is a great amount, x is the measured value.</p><disp-formula id="scirp.21269-formula129469"><label>(4)</label><graphic position="anchor" xlink:href="6-9801324\fd2ae777-a17c-4316-bff0-2b8b2b7876c4.jpg"  xlink:type="simple"/></disp-formula></sec><sec id="s2_2"><title>2.2. Principle of Permanent Magnet</title><p>The permanent magnet, ferromagnetic material type, was selected in this study and the maximum magnetic density was 0.25 Tesla. Two flat-curve permanent magnets was 10 mm wide, 1.5 mm thick, and 41.5 mm long. The outer and inner radius was 24 mm and 19 mm, respectively and the plate curve was 120 degree with the distance of 12 mm. The permanent magnet was mounted parallelly and the magnetic poles were placed in position that can generate the magnetic tension force and can provide the widest linearity range of magnetic density field as shown in Figures 1 and 2.</p></sec></sec><sec id="s3"><title>3. Structure of System Developed</title><p>The subsidence monitoring system presented in this study was developed by applying magnetic field method. There are three important parts of this system is as following; magnetic Field Generation, measuring system (Land subsidence sensing module) and electrical signal system. Details are as follows:</p><sec id="s3_1"><title>3.1. Magnetic Field Generation</title><p>To define the permanent magnet shape for generating the magnetic field, COMSOL software simulation was adopted. The permanent magnets were then positioned to generate magnetic flux in Y-axis direction. Two sets of four magnetic domains (one set consists two domains) were placed alternately in poles as shown in <xref ref-type="fig" rid="fig3">Figure 3</xref>. The appropriate gap of two permanent magnets was fixed at 12 mm, which was half the length of the outer radius of permanent magnet (24 mm). The result obtained from simulation is as shown in <xref ref-type="fig" rid="fig4">Figure 4</xref> where Y-axis is the density of the magnetic field and X-axis is the inclination angle within the permanent magnet radius.</p><p><xref ref-type="fig" rid="fig5">Figure 5</xref> shows the direction of the flat-curve permanent magnet movement. The HES was placed at the center of magnets and perpendicular to X-axis. From experiment, the relationship between output voltage from the HES and magnetic field density generated by two flat-curve permanent magnets were observed. The results agree well to the results from calculation using COMSOL software simulation as shown in <xref ref-type="fig" rid="fig6">Figure 6</xref> [<xref ref-type="bibr" rid="scirp.21269-ref9">9</xref>]. It can be noted that when the permanent magnet was moved, the output voltage from HES would be significantly varied</p><p>at the middle range of permanent magnet. Moreover, it can provide the widest measuring range compared to other different magnet shapes. Therefore, the flat-curve permanent magnet was selected as in this study.</p></sec><sec id="s3_2"><title>3.2. Land Subsidence Sensing Module</title><p>Profile of the measuring system namely Land subsidence sensing module (LSSM) consists of a sensor namely HES [<xref ref-type="bibr" rid="scirp.21269-ref10">10</xref>], placed at the center between two flat-curve permanent magnetic plates with the distance of 12 mm.</p><p>&#160;At the set point of 0 degree as shown in <xref ref-type="fig" rid="fig7">Figure 7</xref>.</p><p>From experiment, the Land Subsidence Sensing Module (LSSM) exhibited high accuracy and reliability. The output voltage from inclination of angle experimented was calibrated using high accurate and precious instruments to setup the system developed as shown in Figures 8 and 9.</p><p><xref ref-type="fig" rid="fig9">Figure 9</xref> illustrates the angle calibration due to magnetic field movement. The high accurate and precious instrument (reference scale) for inclined angle adjustment was installed and defines the position of set point at 0 degree.</p></sec></sec></body><back><ref-list><title>References</title><ref id="scirp.21269-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">V. Hiligsmann and P. Riendeau, “Monolithic 360 Degrees Rotary Position Sensor IC,” IEEE Sensors Conference, Vienna, 24-27 October 2004, pp. 1137-1142.</mixed-citation></ref><ref id="scirp.21269-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">B. Lequesne and T. Schroeder, “High-Accuracy Magnetic Position Encoder Concept,” IEEE Transactions on Industry Applications, Vol. 35, No. 3, 1999, pp. 568-576. 
doi:10.1109/28.767003 </mixed-citation></ref><ref id="scirp.21269-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Y. Y. Lee, R. H. Wu and S. T. Xu, “Applications of Linear Hall-Effect Sensors on Angular Measurement,” 2011 IEEE International Conference on Control Applications (CCA), Denver, 28-30 September 2011, pp. 479-482. 
doi:10.1109/CCA.2011.6044465</mixed-citation></ref><ref id="scirp.21269-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">G. Arfken, “Mathematical Methods for Physicists,” Academic Press, Orlando, 1985, pp. 321-327.</mixed-citation></ref><ref id="scirp.21269-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">C. Chaiyachit, S. Satthamsakul, W. Sriratana and T. Suesut, “Hall Effect Sensor for Measuring Metal Particles in Lubricant,” International Multi Conference of Engineers and Computer Scientists 2012 (IMECS 2012), Hong Kong, 14-16 March 2012, pp. 894-897.</mixed-citation></ref><ref id="scirp.21269-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">L. Tanachaikhan, N. Tammarugwattana, W. Sriratana and P. Klongratog, “Declined Angle Analysis of Shaft Using Magnetic Field Measurement,” ICROS-SICE International Joint Conference 2009, Fukuoka International Congress Center, Fukuoka, 18-21 August 2009, pp. 18461849.</mixed-citation></ref><ref id="scirp.21269-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">E. Ramsden, “Hall-Effect Sensor: Theory and Applications,” Elsevier, Burlington, 2006, pp. 195-196.</mixed-citation></ref><ref id="scirp.21269-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">United Kingdom Accreditation Service, “The Expression of Uncertainty and Confidence in Measurement,” United Kingdom Accreditation Service, London, 1997.</mixed-citation></ref><ref id="scirp.21269-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">W. Sriratana, R. Murayama and L. Tanachaikhan, “Application of the HES in Angular Analysis,” Journal of Sensor Technology, Vol. 2 No. 2, 2012, pp. 87-93. 
doi:10.4236/jst.2012.22013</mixed-citation></ref><ref id="scirp.21269-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">W. Sriratana, K. Nakmee and L. Tanachaikhan, “Subsidence Monitoring System for Industrial Machines Based on Magnetic Field Method,” International Conference on Control, Automation and Systems 2010 (ICCAS 2010), Seoul, 27-30 October 2010, pp. 346-349.</mixed-citation></ref></ref-list></back></article>