<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SS</journal-id><journal-title-group><journal-title>Surgical Science</journal-title></journal-title-group><issn pub-type="epub">2157-9407</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ss.2012.37073</article-id><article-id pub-id-type="publisher-id">SS-21153</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  Continuously Injection with Diluted Heparin Solution via Catheter for Implantation of Totally Implantable Access Ports (TIAP)
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>hien-Hua</surname><given-names>Lin</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jing-Jim</surname><given-names>Ou</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Yueh-Tsung</surname><given-names>Lee</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hurng-Sheng</surname><given-names>Wu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff1"><addr-line>Department of Surgery, Chang-Bing Show Chwan Memorial Hospital, Changhua, Chinese Taipei</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>linjh93@yahoo.com.tw(HL)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>19</day><month>07</month><year>2012</year></pub-date><volume>03</volume><issue>07</issue><fpage>371</fpage><lpage>372</lpage><history><date date-type="received"><day>April</day>	<month>4,</month>	<year>2012</year></date><date date-type="rev-recd"><day>May</day>	<month>12,</month>	<year>2012</year>	</date><date date-type="accepted"><day>May</day>	<month>26,</month>	<year>2012</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Background: Totally implantable access ports (TIAP) could be done in two methods: puncture of subclavian vein and cephalic vein cutdown. Cephalic vein cutdown method has fewer complications but has higher failure rates. We present a method to decrease the failure rates. Methods: We use the continuously injection with diluted heparin solution via catheter while introducing the TIAP catheter into the cephalic vein. Results: From January 2005 to January 2009, 20 patients were performed. This method was successfully applied in 11 patients with no complications. The other 9 patients was unsuccessfully and further underwent guidewire assisted. Conclusions: Continuously injection with diluted heparin solution via catheter while inserting TIAP catheter into the cephalic vein is safe and simple. It could be used for difficulties of insertion of TIAP and increased the successful rates of cephalic vein cut-down method.
 
</p></abstract><kwd-group><kwd>Totally Implantable Access Ports (TIAP); Arrhythmia</kwd><kwd> Port-A</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Totally implantable access ports (TIAP) are often used for the administration of chemotherapy or parental nutrition. TIAP are usually inserted in the subclavian region, and could be completed by two methods: cutdown and percutaneous [<xref ref-type="bibr" rid="scirp.21153-ref1">1</xref>]. We often use cutdown method via cephalic vein because of fewer complications than percutaneous method. However, the cutdown method is dependent of technique and has higher failure rates with range of 6% - 30% [<xref ref-type="bibr" rid="scirp.21153-ref2">2</xref>]. In the past, we used the guidewire assisted method to deal with the difficulty. Recently, we attempt a new technique of cutdown method of TIAP to increase the successful rate.</p></sec><sec id="s2"><title>2. Patients and Methods</title><p>The method is similar to cutdown method of TIAP. Patient was put in supine position and underwent intravenous sedation. A 2 cm incision of infra-clavicular region was made. Identify the cephalic vein, the distal end was ligated and the proximal end was lift. Then introduce the TIAP catheter after a tiny hole over cephalic vein was made.</p><p>Once resistance was found while inserting the TIAP catheter, the assistant would take a syringe of diluted heparin solution (5000 u in 500 mL normal saline) and continuously injection via catheter while insertion (<xref ref-type="fig" rid="fig1">Figure 1</xref>).</p><p>From January 2005 to January 2009, this method was applied in 20 patients; successfully applied in 11 patients with no complications, but unsuccessfully in 9 patients. These 9 patients were further underwent guidewire assisted.</p></sec><sec id="s3"><title>3. Discussion</title><p>Although cutdown method via cephalic vein has fewer complications than percutaneous method, this method has limitation and higher failure rate. The causes of failure may include absence of the cephalic vein, the vein is too small or too difficult for insertion of catheter [2-5].</p><p>Several years ago, we used the guidewire assisted method to deal with this difficulty [<xref ref-type="bibr" rid="scirp.21153-ref5">5</xref>]. Recently, we attempt an easier technique of cutdown method of TIAP to increase the successful rate. This method is maybe more safe than guidewire assisted method. Because using guidewire may have the risk of vascular wall injury [<xref ref-type="bibr" rid="scirp.21153-ref5">5</xref>].</p><p>Continuously injection with diluted heparin solution via catheter may dilate the strict or small cephalic vein and let the catheter pass through easier. The diluted heparin solution would make the vascular wall “smooth”</p><p>and further present from blood clots formation in the lumen of vessel or catheter.</p><p>In conclusion, TIAP with cephalic vein cutdown is a safe method but has higher failure rates. We provide an easier method to deal with difficulty insertion of TIAP catheter. When difficulty insertion of TIAP catheter via cephalic vein happened, you can try continuously injection with diluted heparin solution via catheter while inserting the TIAP catheter. If it didn’t work, you can further try guidewire assisted.</p></sec><sec id="s4"><title>REFERENCES</title></sec><sec id="s5"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.21153-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">S. J. Davis, J. S. Thompson and J. A. Edney, “Insertion of Hickman Catheters. A Comparison of Cutdown and Percutaneous Techniques,” The American Surgeon, Vol. 50, No. 12, 1984, pp. 673-676. </mixed-citation></ref><ref id="scirp.21153-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">S. M. Seiler, B. E. Frohlich, U. J. Dorsam, P. Kienle, M. W. Buchler and H. P. Knaebel, “Surgical Technique for Totally Implantable Access Ports (TIAP) Needs Improvement: A Multivariate Analysis of 400 Patients,” Journal of Surgical Oncology, Vol. 93, No. 1, 2006, pp. 24-29.  
doi:10.1002/jso.20410</mixed-citation></ref><ref id="scirp.21153-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">F. C. Au, “The Anatomy of the Cephalic Vein,” The American Surgeon, Vol. 55, No. 10, 1989, pp. 638-639 </mixed-citation></ref><ref id="scirp.21153-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">T. Chuter and P. M. Starker, “Placement of Hickman-Broviac Catheters in the Cephalic Vein,” Surgery, Gynecology &amp; Obstetrics, Vol. 166, No. 2, 1988, pp. 163-164. </mixed-citation></ref><ref id="scirp.21153-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">H. M. Chang, H. F. Hsieh, S. D. Hsu, G. S. Liao, C. H. Lin, C. B. Hsieh and J. C. Yu, “Guidewire Assisted Cephalic Vein Cutdown for Insertion of Totally Implantable Access Ports,” Journal of Surgical Oncology, Vol. 95, No. 2, 2007, pp. 156-157. doi:10.1002/jso.20584</mixed-citation></ref></ref-list></back></article>