<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">ENG</journal-id><journal-title-group><journal-title>Engineering</journal-title></journal-title-group><issn pub-type="epub">1947-3931</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/eng.2012.45035</article-id><article-id pub-id-type="publisher-id">ENG-19308</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject></subj-group></article-categories><title-group><article-title>
 
 
  Measuring the Thermal Diffusivity in a Student Laboratory
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>melia</surname><given-names>Carolina Sparavigna</given-names></name><xref ref-type="aff" rid="aff1"><sub>1</sub></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><aff id="aff1"><label>1</label><addr-line>Department of Applied Science and technology, Politecnico di Torino, Torino, Italy</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>amelia.sparavigna@polito.it</email></corresp></author-notes><pub-date pub-type="epub"><day>24</day><month>05</month><year>2012</year></pub-date><volume>04</volume><issue>05</issue><fpage>266</fpage><lpage>271</lpage><history><date date-type="received"><day>February</day>	<month>22,</month>	<year>2012</year></date><date date-type="rev-recd"><day>March</day>	<month>20,</month>	<year>2012</year>	</date><date date-type="accepted"><day>March</day>	<month>28,</month>	<year>2012</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  The paper describes a method for measuring the thermal diffusivity of materials having a high thermal conductivity. The apparatus is rather simple and low-cost, being therefore suitable in a laboratory for undergraduate students of engineering schools, where several set-ups are often required. A recurrence numerical approach solves the thermal field in the specimen, which is depending on the thermal diffusivity of its material. The numerical method requires the temperature data from two different positions in the specimen, measured by two thermocouples connected to a temperature logger.
 
</p></abstract><kwd-group><kwd>Thermal Diffusivity; Thermal Conductivity; Aluminium</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>The evaluation of thermal properties of new materials is quite important. For several of their engineering applications in microscopic or macroscopic structures for instance, we need to know how they are able to dissipate heat. The same is true for those systems suitable for the recover or storage of energy [<xref ref-type="bibr" rid="scirp.19308-ref1">1</xref>]. Besides this necessity of measuring the thermal properties of new component materials, the study and development of relevant experimental methods is quite important for researchers and students of engineering schools too. Here then, we propose a method that allows the students to have an experimental approach to the problem of thermal transport.</p><p>Years ago, the author [2-12] has published some papers on new methods to measure the thermal diffusivity. Some measures reported in the references were based on modelling the thermal field inside a specimen after the measure of its thermal expansion. This dilatometric method is able to reduce strongly the experimental errors, which are derived from thermal leaks, but requires a capacitive system to record the thermal expansion. It is therefore not suitable to be used in a laboratory for undergraduate students. Moreover, the instruments are quite expensive.</p><p>Other methods, known as the flash methods, to determine the thermal diffusivity exist. They are based on the use of a laser for heating the specimen. A high-intensity short-duration light pulse is absorbed in the front surface of the specimen and the resulting temperature history of the rear surface is measured, usually by a thermocouple. To cancel the problem of the thermal leaks through the thermocouple wires, the thermal diffusivity can be measured using a non-contact experimental configuration based on infrared photothermal radiometry [<xref ref-type="bibr" rid="scirp.19308-ref15">15</xref>]. This technique reduces the thermal leaks, but, as in the case of dilatometric methods, requires a sophisticate set-up.</p><p>Aiming to improve a laboratory for students with a measure of the thermal diffusivity, without increasing the overalls cost of the structure, we describe here an experimental procedure based on the use of thermocouples, adapting the numerical methods of determining the thermal field developed in Ref. [2-12]. The method of solution is simplified for undergraduate students.</p><p>The paper is structures in the following manner. At first, we describe the experimental set-up. Then the paper proposes the method for evaluating the thermal diffusivity, based on the temperature data obtained by means of two thermocouples. A thermocouple is placed at the lower base of a cylindrical sample and allows calculating the temperature field in the specimen, according to an assumed value of its thermal diffusivity. In such a way, the temperature at the top of the specimen is calculated. The actual value of the thermal diffusivity is obtained by searching, in a certain range of assumed values, for that giving the best agreement of the theoretical temperature with the data recorded by the second thermocouple, placed at the top of the cylinder. Other methods, known as the flash methods, to determine the thermal diffusivity exist [13,14]. In the discussion, we will see that the method provides good results in agreement with previous measurements.</p></sec><sec id="s2"><title>2. Experimental Set-Up</title><p>The instrumentation to be used is very simple. We need two thermocouples and a two-channel temperature logger. I used for students an old device having two large displaysquite useful during room demonstrations, because everybody can see directly the variations of temperature. A cylindrical specimen of commercial aluminium, 16 cm long, is placed on a metal grid, as shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>. Around the cylinder, a layer a few millimetres thick of grey plasticine is used to avoid convective flows. The heat source is applied at the lower base. The heater is an electric resistive coil under an insulating disk. Some students simply used a lighter during the experiments.</p><p>For what concerns the specimen, to reduce the dispersion of heat from its lateral surface, a thermal guard is used of the same material (<xref ref-type="fig" rid="fig2">Figure 2</xref>). The temperature is measured at two different positions in the specimen. One thermocouple is placed at two millimetres from the lower base, in a small diameter hole drilled parallel to the base, through the thermal guard to the axis of the specimen. Since the wires of thermocouple are heated, as the specimen and the thermal guard are, we can consider negligible any thermal leak due to their presence. We can see from <xref ref-type="fig" rid="fig3">Figure 3</xref> how the lower part of the specimen/thermal guard cylinder had been properly shaped.</p><p>The proposed set-up is suitable for measurements with materials possessing a high thermal conductivity (for low-conducting materials, an arrangement as in Ref. [<xref ref-type="bibr" rid="scirp.19308-ref4">4</xref>]</p><p>is more suitable). Due to the high thermal transport, we can assume that the thermal field does not depend on the radial coordinate. The actual length of the specimen that we will consider in the calculation of the thermal field is the distance from the drilled hole in the lower base to the upper base, which is equal to 15.7 cm.</p><p>The second thermocouple is placed at the top of the specimen. Of course, a computer could record the temperatures. In the case that we use the device in <xref ref-type="fig" rid="fig1">Figure 1</xref>, a stopwatch allows to directly read and record the temperatures with a suitable time interval (we used an interval of 10 seconds). The data analysis is done with a numerical program, which is quite simple, as we discuss in the next section.</p></sec><sec id="s3"><title>3. Theoretical Model</title><p>An approach that we can use to solve the thermal transport in the cylindrical specimen is numerical. It is based on a recurrence relation, which uses the temperature measured by the thermocouple at the lower base. After imposing a value of the thermal diffusivity, the temperature field in the cylinder is obtained. Evaluating with the recurrence relation the field at the upper base, we can compare its time behaviour with the temperature recorded by the second thermocouple. The actual thermal diffusivity of the sample is that providing the best agreement between theoretical and experimental values.</p><p>Let us remember that the thermal diffusivity <img src="5-8101613\e8eb983c-c7e2-430f-a82d-c6509e1cfa75.jpg" /> is the physical quantity which appears in the equation of heat:</p><disp-formula id="scirp.19308-formula116202"><label>(1)</label><graphic position="anchor" xlink:href="5-8101613\f9977479-233e-4bef-ae85-9a33898c73d8.jpg"  xlink:type="simple"/></disp-formula><p>To determine the thermal diffusivity, we measure the temperature as a function of time, using at least two thermocouples, as shown in the sketch (<xref ref-type="fig" rid="fig3">Figure 3</xref>) of the cylindrical specimen. As previously discussed, the lower base is heated by means of a suitable heat source: we assume that this base is uniformly heated.</p><p>Using the two thermocouples, the temperature is measured at two different positions. As previously told, one of the thermocouples is inserted laterally at the lower base, passing through the thermal guard. The wires of this thermocouple, having practically the same temperature of the specimen and of the thermal guard, have a negligible perturbation effects on the temperature field. The other thermocouple is inserted on the upper base of the specimen.</p><p>The thermal guard is a hollow cylinder made of the same material of the specimen, a commercial aluminium alloy. The radial distance between the points AB and DE is of a millimetre. The outer diameter of 4 cm. That of the inner cylinder of 2 cm. The total length is 16 cm. The distance of the two thermocouples is 15.7 cm (see <xref ref-type="fig" rid="fig3">Figure 3</xref>).</p><p>Since the material under measurement has a high thermal conductivity, we consider its thermal field depending only on z, not on the radial coordinate. Considering only a dependence on the z-coordinate, this means that each section of the cylinder is reached in a uniform manner by the heat coming from below, and that there is not radial propagations of heat. If the two cylinders are of the same material, positions at the same distance from the base (for example, A, B, C, D, E in <xref ref-type="fig" rid="fig3">Figure 3</xref>) will have the same temperature. We assume that this is true, because of the presence of the thermal guard.</p><p>Admitting that the heat spreads along the longitudinal axis z, and calling T the thermal field in the specimen:</p><disp-formula id="scirp.19308-formula116203"><label>(2)</label><graphic position="anchor" xlink:href="5-8101613\e7396515-c890-4475-8a07-9261b9923b5c.jpg"  xlink:type="simple"/></disp-formula><p>Therefore, the thermal Equation (1) can be written as:</p><disp-formula id="scirp.19308-formula116204"><label>(3)</label><graphic position="anchor" xlink:href="5-8101613\f83cef4d-ab14-48f7-80eb-eed0c7f9cde1.jpg"  xlink:type="simple"/></disp-formula><p>where, <img src="5-8101613\faaac555-0d6d-4a21-9607-09dcbed0b1a4.jpg" />is the thermal diffusivity, K the thermal conductivity, c the specific heat and <img src="5-8101613\94c35bcb-3a25-4b60-b805-150bbe073086.jpg" /> the density.</p><p>To solve this last equation it is necessary to have the thermal field at the initial time of measurements and the boundary conditions. At the initial time condition, we imagine that all the cylinder is at the same temperature, the room temperature, T(t = 0) = T<sub>0</sub>.</p><p>Since the problem is one-dimensional, we need two conditions: one at the lower base, z = 0, and at the top of the cylinder, z = L, where L is the length of the specimen. At the lower base, the temperature is known, because measured by the lower thermocouple. At the top of the specimen we assume a non dispersive boundary condition. From the lateral surfaces, the irradiation of heat is negligible. The thermal exchange with the environment exists for sure, but it can be neglected because air is not flowing between the sample and the thermal guard and the difference between the temperatures of specimen and environment is quite small [<xref ref-type="bibr" rid="scirp.19308-ref9">9</xref>]. In any case, the aim of this method is the use of it for students, and therefore, with some suitable remarks, a non-dispersive condition can be assumed.</p><p>Setting equal to zero the thermal flow between the surface and the environment, we have:</p><disp-formula id="scirp.19308-formula116205"><label>(4)</label><graphic position="anchor" xlink:href="5-8101613\6f09b2d8-9c9f-4467-9ffa-fff98ce04002.jpg"  xlink:type="simple"/></disp-formula><p>Let us consider a solution of Equation (3), for boundary condition (4), in the following form:</p><disp-formula id="scirp.19308-formula116206"><label>(5)</label><graphic position="anchor" xlink:href="5-8101613\9369309a-9afa-4b15-9aa2-cbefb07028f3.jpg"  xlink:type="simple"/></disp-formula><p>According to (4), we have:</p><disp-formula id="scirp.19308-formula116207"><label>(6)</label><graphic position="anchor" xlink:href="5-8101613\481abd3e-2e34-4585-8a2f-104693c570d5.jpg"  xlink:type="simple"/></disp-formula><p>Therefore:</p><disp-formula id="scirp.19308-formula116208"><label>(7)</label><graphic position="anchor" xlink:href="5-8101613\39cc3394-7cd8-4c4d-81c5-b7026d5244a3.jpg"  xlink:type="simple"/></disp-formula><p>where n is an integer ranging from 0 to infinite. Let us use the notation:</p><disp-formula id="scirp.19308-formula116209"><label>(8)</label><graphic position="anchor" xlink:href="5-8101613\31eb2541-4ce7-4404-8db4-f1eb526d73b6.jpg"  xlink:type="simple"/></disp-formula><p>The solution of the thermal transport is obtained as in Refs [2-12]. Let us consider a time interval τ small enough. In fact, we suppose that the time is discretized according to the used data recording of the temperature:</p><disp-formula id="scirp.19308-formula116210"><label>(9)</label><graphic position="anchor" xlink:href="5-8101613\f45141ac-8b5d-4aa3-8bb9-42ce47f0618a.jpg"  xlink:type="simple"/></disp-formula><p>Assume a time<img src="5-8101613\cfb415a3-d0a3-4497-83b7-09e3a1a2083d.jpg" />, at which temperature is recorded, and call:</p><disp-formula id="scirp.19308-formula116211"><label>(10)</label><graphic position="anchor" xlink:href="5-8101613\d095e7c1-88b5-465f-bb55-509d9c947d7e.jpg"  xlink:type="simple"/></disp-formula><p>the temperature field in the specimen during the two time intervals<img src="5-8101613\b1a58622-bcbc-410e-83cd-e30de05d0dd3.jpg" />. We can write:</p><disp-formula id="scirp.19308-formula116212"><label>(11)</label><graphic position="anchor" xlink:href="5-8101613\00533ca0-a82a-4b68-a94b-fb585d35d702.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.19308-formula116213"><label>(12)</label><graphic position="anchor" xlink:href="5-8101613\c52f7378-5972-4fed-b1d1-448dbaaee517.jpg"  xlink:type="simple"/></disp-formula><p>When z = 0, <img src="5-8101613\cf0c1bed-bf0b-4230-9827-c19671da7af0.jpg" />is given by<img src="5-8101613\90a9a21c-583e-4289-9a63-3c8d85c082b5.jpg" />, the temperature measured by the lower thermocouple. Imposing the continuity of the temperature function with respect to time, we have:</p><disp-formula id="scirp.19308-formula116214"><label>(13)</label><graphic position="anchor" xlink:href="5-8101613\69fa56cb-ddb8-407d-9078-dade66e88821.jpg"  xlink:type="simple"/></disp-formula><p>This condition gives us the possibility to evaluate the coefficients <img src="5-8101613\39b6ae64-719c-4fa3-8fa8-ae6e418fd6dc.jpg" /> in the following manner.</p><p>From the continuity condition (13), we have:</p><disp-formula id="scirp.19308-formula116215"><label>(14)</label><graphic position="anchor" xlink:href="5-8101613\33556932-8f3f-4b19-b6fd-48d5a279f37e.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.19308-formula116216"><label>(15)</label><graphic position="anchor" xlink:href="5-8101613\236f6a41-98ef-4e4e-a67b-bf437e8ccc7c.jpg"  xlink:type="simple"/></disp-formula><p>It is necessary to use the fact that:</p><disp-formula id="scirp.19308-formula116217"><label>(16)</label><graphic position="anchor" xlink:href="5-8101613\adb821e3-5345-4d4c-a932-bd02ae5107ce.jpg"  xlink:type="simple"/></disp-formula><p>and:</p><disp-formula id="scirp.19308-formula116218"><label>(17)</label><graphic position="anchor" xlink:href="5-8101613\0fc1af9d-bcfd-4f49-bcef-758286a621a2.jpg"  xlink:type="simple"/></disp-formula><p>Then:</p><disp-formula id="scirp.19308-formula116219"><label>(18)</label><graphic position="anchor" xlink:href="5-8101613\d2b4eb93-2a00-456f-b92d-7288ee739d1b.jpg"  xlink:type="simple"/></disp-formula><p>The following recurrence relation can be use in the numeric calculation:</p><disp-formula id="scirp.19308-formula116220"><label>(19)</label><graphic position="anchor" xlink:href="5-8101613\310c98a9-e135-4bca-a81f-f67314936fb8.jpg"  xlink:type="simple"/></disp-formula><p>For index i:</p><disp-formula id="scirp.19308-formula116221"><label>(20)</label><graphic position="anchor" xlink:href="5-8101613\d7feff39-ee2b-4eb8-bb8d-d361470344c4.jpg"  xlink:type="simple"/></disp-formula><p>In general, the temperature field of the specimen at the time<img src="5-8101613\8fe2a6b4-1c0f-4b4c-9cc6-23cf5d5d906a.jpg" />, is therefore written as:</p><disp-formula id="scirp.19308-formula116222"><label>(21)</label><graphic position="anchor" xlink:href="5-8101613\dd270d4f-a5e9-45d6-bf0b-419c6e8f69e2.jpg"  xlink:type="simple"/></disp-formula><p>We can write this last equation for z = L, the upper base. This theoretical value is a function of the chosen thermal diffusivity.</p><disp-formula id="scirp.19308-formula116223"><label>(24)</label><graphic position="anchor" xlink:href="5-8101613\7e34fbf4-8567-436b-ac9b-c6ebaacf49c2.jpg"  xlink:type="simple"/></disp-formula><p>We can compare it with the temperature <img src="5-8101613\686a9a81-bf54-4dbb-b591-243b5d8289d9.jpg" />recorded by the thermocouple at the upper base of the specimen, by means of the following function:</p><disp-formula id="scirp.19308-formula116224"><label>(25)</label><graphic position="anchor" xlink:href="5-8101613\09c8227c-e8d3-47cb-91d4-4104b83d4388.jpg"  xlink:type="simple"/></disp-formula><p>Minimizing (25), the value of the thermal diffusivity is obtained, giving the best agreement between the model and the experimental measured temperature.</p></sec><sec id="s4"><title>4. Discussion</title><p>As told in the introduction, the method for evaluating the thermal diffusivity is based on the temperature data obtained by means of two thermocouples. A thermocouple is placed at the lower base of a cylindrical specimen, and, as we have seen theoretically, allows calculating the temperature field in the specimen, after a certain value of the thermal diffusivity is assumed. The plot in <xref ref-type="fig" rid="fig4">Figure 4</xref> is giving the value of the temperature recorded by the thermocouple at the base of the specimen as the data T<sup>(1)</sup> as a function of time. From data T<sup>(1)</sup>, as previously shown, we can calculate the temperature at the top of the specimen and compare with the experimental behaviour T<sup>(2)</sup> recorder by the second thermocouple.</p><p>In <xref ref-type="fig" rid="fig4">Figure 4</xref>, it is shown an experiment during which the specimen was heated for three minutes approximately. The two temperatures were recorded each ten seconds.</p><p>The thermal diffusivity of the material under investigation is obtained by searching, in a certain range of assumed values of this physical quantity, for that value giving the best agreement of the theoretical temperature with that recorded by the second thermocouple, placed at the top of the cylinder. Applying the numerical procedure described in the previous section, I(a) as a function of the thermal diffusivity is obtained. The behaviour of this function for the data of <xref ref-type="fig" rid="fig4">Figure 4</xref> is given in <xref ref-type="fig" rid="fig5">Figure 5</xref>. This function has a well-defined minimum.</p><p>The value of the thermal diffusivity giving the best agreement with experimental data of <xref ref-type="fig" rid="fig4">Figure 4</xref> is therefore 0.79 cm<sup>2</sup>/s. Repeating some measurements on the same specimen, we obtained a value of the thermal diffusivity of (0.75 &#177; 0.07) cm<sup>2</sup>/s. This measure is in good agreement with the values obtained in a more controlled environment [2,7-9,15]. The dispersion of the values is larger, but this is not surprising, because it is difficult to repeat the measures in the same conditions. Moreover, there is the possibility that convective heat flows exist during the heating of the specimen.</p></sec><sec id="s5"><title>5. Conclusion</title><p>As we have shown, the method gives measures of the thermal diffusivity in good agreement with previous measurements. Of course, the accuracy of the method can be improved preparing a small box for the set-up and create the vacuum in it with a rotative pump, but this is beyond the aim of the proposed approach, which is the use of it in a student laboratory. For what concerns the calculation, the numerical recurrence is quite simple to be implemented by an undergraduate student on a personal computer. Moreover, the apparatus has a low-cost, and therefore several replicas can be prepared without being their cost exceedingly large for the financial support of the laboratory.</p></sec><sec id="s6"><title>REFERENCES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.19308-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">A. C. Sparavigna, S. Giurdanella and M. Patrucco, “Behaviour of Thermodynamic Models with Phase Change Materials under Periodic Conditions,” Energy and Power Engineering, Vol. 3, No. 2, 2011, pp. 150-157.  
doi:10.4236/epe.2011.32019</mixed-citation></ref><ref id="scirp.19308-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">A. Sparavigna, “Nuovo Metodo Dilatometrico di Misura Della Diffusività Termica dei Solidi,” Ph.D. Dissertation, Politecnico di Torino, Torino, 1990.</mixed-citation></ref><ref id="scirp.19308-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">A. Sparavigna, M. Omini, A. Pasquarelli and A Strigazzi, “Thermal Diffusivity of Amorphous Plastic Materials,” High Temperatures—High Pressures, Vol. 24, No. 2, 1992, pp. 175-178. </mixed-citation></ref><ref id="scirp.19308-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">A. Sparavigna, M. Omini, A. Pasquarelli and A. Strigazzi, “Thermal Diffusivity and Conductivity in Low-Conducting Materials: A New Technique,” International Journal of Thermophysics, Vol. 13, No. 2, 1992, pp. 351- 360. doi:10.1007/BF00504442 </mixed-citation></ref><ref id="scirp.19308-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">M. Omini, A. Sparavigna and A. Strigazzi, “Thermal Diffusivity of Solids with Low Expansion Coefficient: A Dilatometric Technique,” International Journal of Thermophysics, Vo. 13, No. 4, pp. 711-718, 1992.  
doi:10.1007/BF00501951</mixed-citation></ref><ref id="scirp.19308-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">G. Giachello, M. Omini, A. Sparavigna and A. Strigazzi, “Thermal Diffusivity in Low Conducting Solids: A Capacitive Method,” Physica Scripta, Vol. 42, No. 4, 1990, pp. 439-441. doi:10.1088/0031-8949/42/4/010 </mixed-citation></ref><ref id="scirp.19308-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">A. Sparavigna, G. Giachello, M. Omini and A. Strigazzi, “High-Sensitivity Capacitance Method for Measuring Thermal Diffusivity and Thermal Expansion: Results on Aluminum and Copper,” International Journal of Thermophysics, Vo. 11, No. 6, 1990, pp. 1111-1126.  
doi:10.1007/BF00500564</mixed-citation></ref><ref id="scirp.19308-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">M. Omini, A. Sparavigna and A. Strigazzi, “Thermal Diffusivity and Biot Number: A New Experimental Technique,” Applied Physics A, Vol. 50, No. 1, 1990, pp. 35- 37. doi:10.1007/BF00323951</mixed-citation></ref><ref id="scirp.19308-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">M. Omini, A. Sparavigna, A. Strigazzi and G. Teppati, “A Ring-Source Method to Measure the Thermal Diffusivity of a Conducting Specimen in Forced Air Flow: Study on Aluminum,” Nuovo Cimento D, Vol. 12, No. 1, 1990, pp. 79-101. doi:10.1007/BF02453029</mixed-citation></ref><ref id="scirp.19308-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">M. Omini, A. Sparavigna and A. Strigazzi, “Dilatometric Determination of Thermal Diffusivity in Low Conducting Materials,” Measurement Science &amp; Technology, Vol. 1, No. 2, 1990, pp. 166-171. doi:10.1088/0957-0233/1/2/011</mixed-citation></ref><ref id="scirp.19308-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">M. Omini, A. Sparavigna and A. Strigazzi, “Calibration of Capacitive Cells for Dilatometric Measurements of Thermal Diffusivity,” Measurement Science &amp; Technology, Vol. 1, No. 11, 1990, pp. 1228-1231. 
doi:10.1088/0957-0233/1/11/015</mixed-citation></ref><ref id="scirp.19308-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">M. Omini, A. Sparavigna and A. Strigazzi, “Thermal Diffusivity and Thermal Expansion in High-Conducting Materials: A Capacitance Method,” Europhysics Letters, Vol. 10, No. 2, 1989, pp. 129-134. 
doi:10.1209/0295-5075/10/2/007</mixed-citation></ref><ref id="scirp.19308-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">W. J. Parker, R. J. Jenkins, C. P. Butler and G. L. Abbott, “Flash Method of Deter-mining Thermal Diffusivity, Heat Capacity, and Thermal Conductivity,” Journal of Applied Physics, Vol. 32, No. 9, 1961, pp. 1679-1685.  
doi:10.1063/1.1728417</mixed-citation></ref><ref id="scirp.19308-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">J. A. Cape and G. W. Lehman, “Temperature and Finite Pulse-Time Effects in the Flash Method for Measuring Thermal Diffusivity,” Journal of Applied Physics, Vol. 34, No. 7, 1963, pp. 1909-1914. doi:10.1063/1.1729711</mixed-citation></ref><ref id="scirp.19308-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">E. MacCormack, A. Mandelis, M. Munidasa, B. Farahbakhsh and H. Sang, “Measurements of the Thermal Diffusivity of Aluminum Using Frequency-Scanned, Transient, and Rate Window Photothermal Radiometry. Theory and Experiment,” International Journal of Thermophysics, Vol. 18, No. 1, 1997, pp. 221-250.  
doi:10.1007/BF02575209</mixed-citation></ref></ref-list></back></article>