<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">WJNST</journal-id><journal-title-group><journal-title>World Journal of Nuclear Science and Technology</journal-title></journal-title-group><issn pub-type="epub">2161-6795</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/wjnst.2012.21006</article-id><article-id pub-id-type="publisher-id">WJNST-16563</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Engineering</subject><subject> Physics&amp;Mathematics</subject></subj-group></article-categories><title-group><article-title>
 
 
  U and Th Determination in Natural Samples Using CR-39 and LR-115 Track Detectors
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>.</surname><given-names>A. Eman</given-names></name></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>S.</surname><given-names>H. Nageeb</given-names></name></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>A.</surname><given-names>R. El-Sersy</given-names></name><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib></contrib-group><author-notes><corresp id="cor1">* E-mail:<email>aelsersy@yahoo.com(ARE)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>04</day><month>01</month><year>2012</year></pub-date><volume>02</volume><issue>01</issue><fpage>36</fpage><lpage>40</lpage><history><date date-type="received"><day>June</day>	<month>17,</month>	<year>2011</year></date><date date-type="rev-recd"><day>August</day>	<month>29,</month>	<year>2011</year>	</date><date date-type="accepted"><day>October</day>	<month>27,</month>	<year>2011</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  In this work, a simple and accurate method for U and Th determination in natural samples is proposed. This method is based on simplified calculations of the efficiency factor of the solid state track detector using a thin source approach. Samples were firstly saluted using a concentrated H
  <sub>2</sub>SO
  <sub>4</sub> acid and then distributed on a glassy slide where the thickness of the sample was about 7 μm. CR-39 and LR-115 track detectors were exposed to the thin layer of the natural samples for few days and then the track densities were obtained. By the mean of originated track densities in CR-39 and LR-115 as a function of exposure time and sample weight, the concentration of U and Th in Bq/kg were obtained by the thin source approach of SSNTD.
 
</p></abstract><kwd-group><kwd>U; Th; CR-39 and LR-115</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Solid State Nuclear Track Detectors, SSNTD are widely used in different applications related to α-track registration [1-4]. One of the most applications is the U and Th determination in natural materials. Th in natural samples is usually more abundant than U by a factor of about 4, so it is necessary to calculate the ratio of Th/U in order to perform a quantitative analysis of uranium and thorium in natural samples [5,6] but this ratio is related to the geological structure of samples.</p><p>Different tools have been used for Th content as isotope dilation mass spectroscopy chromatography. Inductive coupled plasma mass spectrometry, neutron activetion analysis, α-spectrometry using SSNTD. The use of SSNTD has many advantages than the others due to the long term exposure property and the alpha track counting is performed without any electronic attachment.</p><p>Using SSNTDs, the general relation used for concentration determination of U or Th in CR-39 or LR-115 are given in Equations (1) through (4) [<xref ref-type="bibr" rid="scirp.16563-ref5">5</xref>].</p><disp-formula id="scirp.16563-formula118195"><label>(1)</label><graphic position="anchor" xlink:href="6-1090023\7efc5136-774b-4677-9d42-87ec1e6046c1.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.16563-formula118196"><label>(2)</label><graphic position="anchor" xlink:href="6-1090023\842f0b78-7aeb-49f5-a313-87ac3acd32a6.jpg"  xlink:type="simple"/></disp-formula><p>where <img src="6-1090023\2d6b12b3-34a6-49ce-b5b2-fc057c29217d.jpg" /> and&#160; <img src="6-1090023\03adb5c7-1625-4b5d-b83c-6fd1b7b7b6ae.jpg" /> are the registered track densities of U and Th, series respectively. C<sub>U</sub> and C<sub>Th</sub> are the concentrations of U and Th in the natural sample. k<sub>U</sub> and k<sub>Th</sub> are the α registration efficiency from U and Th series, respectively and so for LR-115 C<sub>U</sub> and C<sub>Th</sub> are:</p><disp-formula id="scirp.16563-formula118197"><label>(3)</label><graphic position="anchor" xlink:href="6-1090023\678e15df-ed3d-4f54-be3d-3e7de56c0179.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.16563-formula118198"><label>(4)</label><graphic position="anchor" xlink:href="6-1090023\689a989f-da19-46e1-bf54-d1d2d42c1975.jpg"  xlink:type="simple"/></disp-formula><p>Then the total track density of CR-39 is</p><disp-formula id="scirp.16563-formula118199"><label>(5)</label><graphic position="anchor" xlink:href="6-1090023\84d8f6b9-ab8f-499e-8eb8-9d835d871658.jpg"  xlink:type="simple"/></disp-formula><p>And for LR</p><disp-formula id="scirp.16563-formula118200"><label>(6)</label><graphic position="anchor" xlink:href="6-1090023\237c3044-3cff-4908-9432-18d07020c039.jpg"  xlink:type="simple"/></disp-formula><p>From Equations (5) and (6), the track density ratio of CR-39 to LR-115 is</p><disp-formula id="scirp.16563-formula118201"><label>(7)</label><graphic position="anchor" xlink:href="6-1090023\b34cffc0-1158-4b92-b064-9ccaa5ad2e84.jpg"  xlink:type="simple"/></disp-formula><p>The efficiency factor for thick source is given by Equations (8) and (9):</p><disp-formula id="scirp.16563-formula118202"><label>(8)</label><graphic position="anchor" xlink:href="6-1090023\145071e0-6d08-4231-b5fa-fdc4481c9294.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.16563-formula118203"><label>(9)</label><graphic position="anchor" xlink:href="6-1090023\e3ebee0f-68a4-44b2-86f1-6020f89bc4dc.jpg"  xlink:type="simple"/></disp-formula><p>where R<sub>i</sub> and θ<sub>ci</sub> are the range and the critical angle of isotopes in U and Th series, respectively [<xref ref-type="bibr" rid="scirp.16563-ref7">7</xref>].</p></sec><sec id="s2"><title>2. Method of Calculations</title><p>From Equations (8) and (9), both of α range (R) and the critical angle of etching (θ<sub>c</sub> ) should be determined for efficiency calculation. For accurate calculation the α range from U and Th series, chemical analysis should be performed for the natural containing radioactive material. Also θ<sub>c</sub> for 14 different alpha energies should be obtained, which sometimes very sophisticated.</p><p>In this work, a thin source approach was proposed, where the efficiency factor in Equations (8) and (9) could be written as for U and Th:</p><disp-formula id="scirp.16563-formula118204"><label>(10)</label><graphic position="anchor" xlink:href="6-1090023\e5a7a40b-0ddc-42a7-a1c6-3f7ca4403166.jpg"  xlink:type="simple"/></disp-formula><disp-formula id="scirp.16563-formula118205"><label>(11)</label><graphic position="anchor" xlink:href="6-1090023\b1882233-5f0e-41fb-a1b2-395a6cae12fb.jpg"  xlink:type="simple"/></disp-formula><p>From Equations (10) and (11), one can notice that efficiency depends only on the critical angle θ<sub>c</sub> which is easily known as a function of α energy [<xref ref-type="bibr" rid="scirp.16563-ref7">7</xref>].</p><p>Using the thin source technique, with CR-39 Equation (5) can be rewritten as:</p><disp-formula id="scirp.16563-formula118206"><label>(12)</label><graphic position="anchor" xlink:href="6-1090023\e77b5d1b-aff6-4a23-a5bd-36c978300fdf.jpg"  xlink:type="simple"/></disp-formula><p>where k<sub>U thin</sub> and k<sub>Th thin</sub> can be calculated from Equations (10) and (11) which yield to the determination of C<sub>U</sub> + C<sub>Th</sub>. So other relations are needed to get both C<sub>U</sub> and C<sub>Th</sub>, which can be obtained from LR-115 data.</p><p>By considering Th series [9-10], one can notice that the series contains 6 alpha particle emitters with energies higher than 4.5 (window of LR-115 detector [<xref ref-type="bibr" rid="scirp.16563-ref8">8</xref>]) only <sup>232</sup>Th has α energy of value 4.08 MeV [9,10]. So when thin layer of sample is used with LR-115 it will only register the 4 α from U-series with energy smaller than 4.5 MeV, then</p><disp-formula id="scirp.16563-formula118207"><label>(13)</label><graphic position="anchor" xlink:href="6-1090023\d2f37e58-295f-4d25-ba90-2c28a477e6b2.jpg"  xlink:type="simple"/></disp-formula><p>From Equations (12) and (13) both of C<sub>U </sub>&#160;and C<sub>Th</sub> are easily obtained.</p></sec><sec id="s3"><title>3. Experimental</title><p>Natural samples are collected from Oil fields at the beach of the Meditraian Sea near Domiat and Kafer El-Skeekh north east of Cairo, Egypt. Samples were grinded to very small grain size. A very small mass of each sample was added to concentrated solution of H<sub>2</sub>SO<sub>4</sub> acid. The resulted solution was distributed on a glass slide where the thickness of the sample on the slide is in the range of 7 μm.</p><p>CR-39 and LR-115 detectors were exposed, in closed contact, to the samples for few days. Detectors were collected and etched at the optimum etching conditions. Track density originated in CR-39 and LR-115 was counted using an image analyzer model ELBEK SAMICA, Germany.</p></sec><sec id="s4"><title>4. Results and Discussion</title><p>Colleted samples were coded with numbers from 1 to 10 and about 300 mg of sample was used and distributed on a glassy slide. The originated tracks (cm<sup>–2</sup>&#183;g<sup>–1</sup>&#183;sec<sup>–</sup><sup>1</sup>) in CR- 39 and LR-115 within 15 day exposure were counted and illustrated in <xref ref-type="fig" rid="fig1">Figure 1</xref>.</p><p>From the track densities in CR-39 and LR-115, two methods of calculation were used. These methods were method 1 where the contribution of track density in LR-115 from Th is neglected and Method 2 where track density from Th in LR is considered.</p><sec id="s4_1"><title>4.1. First Method</title><p>Values of alpha energies in U and Th series are given in references 9 and 10.</p><p>In this approximation neglecting the contribution in track density from Th series in LR-115, the U activity concentration can be determined from Equation (13) and represented in <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p><p>From the obtained U concentration, and by substituting in Equation (12), the Th concentration is obtained and illustrated in <xref ref-type="fig" rid="fig3">Figure 3</xref>.</p></sec><sec id="s4_2"><title>4.2. Second Method</title><p>In this method, all alpha energies closed to 4.5 MeV or below are considered in LR-115 registration from both U and Th series. In this method Equation (13) can be written as:</p><disp-formula id="scirp.16563-formula118208"><label>(14)</label><graphic position="anchor" xlink:href="6-1090023\775aa094-f474-4960-b6c7-ce7692fe1715.jpg"  xlink:type="simple"/></disp-formula><p>The obtained U concentration from this method is</p><p>illustrated in <xref ref-type="fig" rid="fig4">Figure 4</xref>.</p><p>The Th concentration is calculated from Equations (13) and (14) using the values of C<sub>U</sub> and represented in <xref ref-type="fig" rid="fig5">Figure 5</xref>.</p><p>To cheek the variation between these two methods, a comparison between U concentrations calculated from the two approximations is represented in <xref ref-type="fig" rid="fig6">Figure 6</xref>. From <xref ref-type="fig" rid="fig6">Figure 6</xref>, one can notice that, the U concentration calculated by Method 1 is slightly grater that obtained from Method 2.</p><p>By the same procedure a comparison between Th concentrations calculated by the two methods is represented in <xref ref-type="fig" rid="fig7">Figure 7</xref> where nearly same value of Th concentration is noticed.</p><p>From Figures 6 and 7, one can notice that, there is a good agreement between theses two methods of U and Th calculations where a correlation factor of 86% and 89% for U and Th, respectively. Also one can use Method 1 as an easy method for U and Th calculation using SSNTDs with reasonable accuracy.</p><p>To assure the U and Th concentrations obtained from this study, one has two directions. The first one is the confirmation of the results by other technique used for U and</p><p>Th detection. Three samples were selected and then the content U and Th were measured by gamma spectroscopic technique calibrated by a standard multi-radionuclide source traceable to the National Institute for Standard and Technology (NIST) at USA. The obtained correlation coefficient is 87% and 84% for U and Th concentrations that reflects a good agreement between the two techniques.</p><p>The second direction of confirmation is the comparison of the obtained data with that published in the literature. The world average of U and Th concentrations as re-</p><p>ported in the UNSCEAR, 1988 [<xref ref-type="bibr" rid="scirp.16563-ref11">11</xref>] is 25 Bq/kg. The average U and Th concentrations in the studied samples as obtained from Method 2 are 46.38 and 31.02 Bq/kg, respectively. From this data, one can notice that the obtained results are in the same order of that obtained in the UNSEAR and El-Daly et al., 2008 [<xref ref-type="bibr" rid="scirp.16563-ref12">12</xref>].</p><p>Ratio of Th/U is calculated and represented in <xref ref-type="fig" rid="fig8">Figure 8</xref> where the average ratio for all samples is 0.80 with stander deviation of 0.55. The variation of this ratio may be attributed to the collection of the studied samples was from one zone and different depth that reflected the difference of the geological stricture for each depth.</p></sec></sec><sec id="s5"><title>5. Conclusion</title><p>From this work, one can conclude that, SSNTDs can be used for U and Th determination in natural samples. The suggested thin source used is applicable for U and Th determination without sophisticated calculations. Also, the first approximation is accurate and easy for U and Th determination. The correlation between the two methods of calculations is 88% and 86% for U and Th values that reflected the applicability of method one. Also the obtained U and Th concentrations were in a good agreement with the gamma spectroscopic technique.</p></sec><sec id="s6"><title>REFERENCES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.16563-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">T. EL-Zakla, H. A. Abdel-Ghny and A. M. Hassan, “Natural Radioactivity of Some Local Fertilizers,” Romanian Journal of Physics, Vol. 52, No. 5-7, 2007, p. 731. </mixed-citation></ref><ref id="scirp.16563-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">H. Florou, K. Kehagia, C. H. Chaloulou, V. Koukouliou and C. H. Lykomitrou, “Determination of Radionuclide in Mystiques Galloprovicialis by Alpha and Gamma-Spec- troscopy,” Mediterranean Marine Science, Vol. 5, No. 1, 2004, p. 117.</mixed-citation></ref><ref id="scirp.16563-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">C. A. Simion, C. Cimpeanu, C. Barna and E. Duta, “The Uranium Determination in Commercial Iodine Salt,” Romanian Journal of Physics, Vol. 51, No. 7-8, 2006, p. 845.</mixed-citation></ref><ref id="scirp.16563-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">N. W. El-Dine, A. El-Shershaby, F. Ahmed and A. S. Abdel-Haleem, “Measurement of Radioactivity and Radon Exhalation Rate in Different Kinds of Marbles and Granites,” Applied Radiation and Isotopes, Vol. 55, 2001, p. 853. doi:10.1016/S0969-8043(01)00107-5</mixed-citation></ref><ref id="scirp.16563-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">T. A. Salama, U. Seddik, T. M. Dsoky, A. Morsy and R. Asser, “The Influence of the Nature of Soil and Plant and Pollution on the 238U, 232Th, 222Rn and 220Rn Concentrations in Various Natural Honey Samples Using Nuclear Track Detectors: Impact on the Adult Consumers,” Indian Academy of Sciences, Vol. 62, No. 2, 2006, p. 269.</mixed-citation></ref><ref id="scirp.16563-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">H. Surbeck, “Alpha Spectrometry Sample Preparation Using Selectively Adsorbing Thin Films,” ICRM Conference on Low Level Radioactivity Measurement Techniques, Mol, Belgium, 18-22 October, 1999, pp. 97-100.</mixed-citation></ref><ref id="scirp.16563-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">M. M. El-Hawary, M. M. Mansy, A. Hussein, A. A. Ammar and A. R. El-Sersy, “Construction of a Charged Particle Irradiation Chamber for the Use with Plastic Detectors,” Radiation Physics and Chemistry, Vol. 54, 1999, p. 547. doi:10.1016/S0969-806X(98)00292-8</mixed-citation></ref><ref id="scirp.16563-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">H. El-Samman, M. Mansy, A. Hussein, M. El-Hawary and A. R. El Sersy, “Registration Efficiency of Some SSNTDs with Source Area Included,” Nuclear Instruments and Methods in Physics Research Section B, Vol. 155, 1999, p. 426. doi:10.1016/S0168-583X(99)00485-1</mixed-citation></ref><ref id="scirp.16563-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">“Uranium Series ICRP 68 Dose Coefficients for Workers,” 2003. http://www.wise-uranium.org/rdfi68.html</mixed-citation></ref><ref id="scirp.16563-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">National Service Center for Environmental Publications (NSCEP), 2007.  
http://www.epa.gov/radiation/heast/docs/heast2</mixed-citation></ref><ref id="scirp.16563-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation), “Sources Effects and Risks of Ionizing Radiation,” Report to the General Assembly, With Annexes, United Nations, New York, 1988.</mixed-citation></ref><ref id="scirp.16563-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">T. A. El-Daly and A. S. Hussein, “Natural Radioactivity Level in Environmental Samples in North Western Desert of Egypt,” Proceedings of the 3rd Environmental Physics Conference, Aswan, Egypt, 19-23 February 2008, pp. 79-88.</mixed-citation></ref></ref-list></back></article>